Mr. D. H. Cook Trlr. 5583 (511)
Mr. G. F. Hurley Mr. R. F. Painter Mr. H. L. Robinson Mr. E. C. Shipley
Date May 25, 1979
Originating Dept, Technical Center IH/EP
Subject
Asbestos - Stripping Old Insulation
PROJECT Survey for asbestos exposure of insulators stripping insula
tion from still column in Building 707.
DATE OF SURVEY
May 15, 1979
SUMMARY Exposures were higher than expected for this demolition job,
2.2 and 0.9 fibers/cc TWA for Finney and Miller respectively. The fact that they were wearing respirators allowed the normal standard without protection of 2 fibers/cc TWA to be extended ten times when employees are protected during demolition or removal of material containing asbestos. This exception only pertains to work situations where it is not feasible to control dust with engineering controls.
DISCUSSION Construction insulators were asked to remove insulation from
BS-62 in Cell-11 of Building 707. This still column extends through three levels of the cell and is approximately eight inches in diameter. The insulation was wet down with water as much as possible and every precaution to reduce asbestos exposure to employees was followed. These precautions include; approved dis posable dust respirators, coveralls, gloves and bagging and labeling of stripped insulation for landfill.
UCC 024351
- Mr.. D. H. Cook
2
5/25/79
The Technical Center Industrial Hygiene group sampled the insulators in the morning of the fifteenth and for a portion of the stripping job in the afternoon. From the data collected, we were able to determine the time-weighted average of asbestos exposure for Mr. Charles Miller and Mr. M. Finney. (See following results.)
RECOMMENDATION
The best control for asbestos exposure is wetting the material down before demolition starts and to follow the outline prescribed in the Construction Department Safety Procedure Manual, Section VIII, Procedure 22. We would like to emphasize the importance of this procedure and especially the instructions found in paragraph three.
RESULTS
Date 5/15/79 5/15/79 5/15/79 5/15/79
Personnel M. Finney M. Finney C. Miller C. Miller
Time 0950-1115 1300-1400 0950-1115 1300-1400
Liters of Air
170 120 170
120
Exposure, Fibers/cc >5 pm
TWA
4.6]
.<
6 l]
------j> 2.2
2.0l <
2.lJ
------> 0.9
REFERENCES
Volume 38C-29X4-Rla Asbestos, Dust Determination By Membrane Filter Technique Using Phase Contrast Microscopy
REPORT PREPARED BY
G. W. Bott Technical Center Industrial Hygiene Department
APPROVED BY G/ F. Hurley