Document J6xXKQxN8jQrwN8dk5rOVjxv
PROGRESS REPORT
Cl R!. I..,. 11/531
ORGANIC CHEMICALS DIVISION
St. Louis Research Department
Reported By: A- M. Ellenburg
Reported from Anniston
Job No. 117-2681 Report No. (J>)
Date: March, 1954
Information contained here/n It CONFIDENTIAL and It fft* property of Mensonfo Chemical Company
A-tSt. L_qv1i
At WGK Plant
35. G. R. Buchanan - St. Louis
25-29-
36-
1 Library
13 R.O. Nellums
30 Development
37-
la Library 2 D.M. Campbell
14 O.J. Weinkauff 15 J.R. Wilson
At J.F.Q. Plant
3839-
3 H.W. Faust 4 L.L. Fellingsr
16 F. B. Zlenty 17 0. DeGarmo
31-
4041-
S H.R. Gamrath
18 J F Q Development
42-
6 R.M. Hitchens 7 C.A. Hochwatt
19 J.R, Durland 20 R. M. Motrls
At N Ifro 32-W.P. Metzner
4344-
8 R.E. Howard
21 J. H. Lum
45-
9 D. S. Weddell 10 R.H. Munch
22 P.G. Marsh 23 J. L. Hammer
At Dayton 33 L. Lederman
4647-
1 1 F.M. Murdock
24 B.E. Thomas
34 N.N.T. Samaras
46-
12 H.K. Nason
49-
Tjf|d:
Assistance to Sales and Development Departments on Aroclor and Biphenyl.
Problem: ^o anflJ-Jr2e samples of /a or ,vi- 1248 that had been tested in an Aroclor heater at the International Boiler Worts Company at East Stroudsburg, Pennsylvania.
A series of samples was received from the International Boiler Works Company for analysis. These samples were taken at weekly intervals over a four week period while the Aroclcr 1248 was operating at 650F. under }0 psig. nitrogen pressure.
Ihere was little change in the acidity of the Aroclor which indicates that most of the HC1 formed was volatilized out of the Aroclor. The specific gravity and the viscosity show the progress of deterioration of the Aroclor 1248.
AROCLOR 1248 HEATED AT 650F.
Sample
Hours Heated
Saybolt Seconds Sp. Gr, at 63/15.5 Viscosity at 130F.
Starting Aroclor 1 2 3 A
0 168 336 500 668
1.406 1.408 1.408
1.409 1.410
76.3 80.8
88.5 97.8 110.4
0132702
HARTOLDMONOOQ4798
Page
JtoNo. 117-268l(3) ate March, 195^
The increase in viscosity definitely shows polymerization in the Aroclar and means that the Aroclor will need to he replaced after several months opera tion at 650^,
At 600PF,, previous tests had shown only a 2 second increase in viscosity after 4 weeks heating. Ihus 600F. is the maximum safe temperature for heat ing the Aroclor 1246 without decomposition. At 650F. cauticn must be taken to remove the Aroclor at intervale before it decomposes to a tar.
A. M. Ellenburg kd
0]32703
HARTOLDMONOOQ4799