Document J6xXKQxN8jQrwN8dk5rOVjxv

PROGRESS REPORT Cl R!. I..,. 11/531 ORGANIC CHEMICALS DIVISION St. Louis Research Department Reported By: A- M. Ellenburg Reported from Anniston Job No. 117-2681 Report No. (J>) Date: March, 1954 Information contained here/n It CONFIDENTIAL and It fft* property of Mensonfo Chemical Company A-tSt. L_qv1i At WGK Plant 35. G. R. Buchanan - St. Louis 25-29- 36- 1 Library 13 R.O. Nellums 30 Development 37- la Library 2 D.M. Campbell 14 O.J. Weinkauff 15 J.R. Wilson At J.F.Q. Plant 3839- 3 H.W. Faust 4 L.L. Fellingsr 16 F. B. Zlenty 17 0. DeGarmo 31- 4041- S H.R. Gamrath 18 J F Q Development 42- 6 R.M. Hitchens 7 C.A. Hochwatt 19 J.R, Durland 20 R. M. Motrls At N Ifro 32-W.P. Metzner 4344- 8 R.E. Howard 21 J. H. Lum 45- 9 D. S. Weddell 10 R.H. Munch 22 P.G. Marsh 23 J. L. Hammer At Dayton 33 L. Lederman 4647- 1 1 F.M. Murdock 24 B.E. Thomas 34 N.N.T. Samaras 46- 12 H.K. Nason 49- Tjf|d: Assistance to Sales and Development Departments on Aroclor and Biphenyl. Problem: ^o anflJ-Jr2e samples of /a or ,vi- 1248 that had been tested in an Aroclor heater at the International Boiler Worts Company at East Stroudsburg, Pennsylvania. A series of samples was received from the International Boiler Works Company for analysis. These samples were taken at weekly intervals over a four week period while the Aroclcr 1248 was operating at 650F. under }0 psig. nitrogen pressure. Ihere was little change in the acidity of the Aroclor which indicates that most of the HC1 formed was volatilized out of the Aroclor. The specific gravity and the viscosity show the progress of deterioration of the Aroclor 1248. AROCLOR 1248 HEATED AT 650F. Sample Hours Heated Saybolt Seconds Sp. Gr, at 63/15.5 Viscosity at 130F. Starting Aroclor 1 2 3 A 0 168 336 500 668 1.406 1.408 1.408 1.409 1.410 76.3 80.8 88.5 97.8 110.4 0132702 HARTOLDMONOOQ4798 Page JtoNo. 117-268l(3) ate March, 195^ The increase in viscosity definitely shows polymerization in the Aroclar and means that the Aroclor will need to he replaced after several months opera tion at 650^, At 600PF,, previous tests had shown only a 2 second increase in viscosity after 4 weeks heating. Ihus 600F. is the maximum safe temperature for heat ing the Aroclor 1246 without decomposition. At 650F. cauticn must be taken to remove the Aroclor at intervale before it decomposes to a tar. A. M. Ellenburg kd 0]32703 HARTOLDMONOOQ4799