Document J3xd73djpvBYGGN6OwM0JpNz2

RESEARCH DEPARTMENT - PHOSPHATE DIVISION SHORT FORM REPORT Report No.! 2790 Work Started! October 15, 1951 Work Completed! May 15, 1952 Date Reported! July 3, 1952 Job No. i File No.! 171-1028 141-27-3 Investigators! A. M. Ellenburg H. B. Richards, Jr. J. E. Feltham Distribution: Research File R. L. Jenkins - St. Louis H. V. Moss C. A. Hochwalt - St. Louis N. N. T. Samaras - Dayton Edgar E. Hardy H. F. Weaver - St. Louis A. M. Ellenburg W. T. Durrett R. P. Loeiren H. 0. Tittel C. Barbre - Monsanto, 111. T. W. Dalton - Monsanto, 111. Jack Clegorn Extra (2) TITLE! Increased Production of Aroclor by More Rapid Rate of Chlorination. INTRODUCTION! In view of the desired eight-million pound per year increase in distilled Aroclor produc tion, plant experiments were made increasing the rate of chlorination of biphenyl to crude liquid Aroclors to determine if the Aroclors so produced would meet the present specifica tions . ' SUMMARY! Several experimental chlorinations in chlorinators 5 and 6, which have been modified for more rapid chlorination rates, were carried out on batches of 1142 and 1154 at increased chlorination rates. These fast chlorinations (up to 770 pounds chlorine per hour) were compared to normal operations (550 pounds chlorine feed) it) these modified chlorinators and to normal operations (400 pounds chlorine feed) in chlorinators 3 and 4, which have not been modified for rapid chlorination. In all cases the Aroclors produced at the increased rates were within specifications. CONCLUSIONS! 1. Production of crude Aroclors with existing equipment has been increased about 30# in modified chlorinators 5 and 6. 2. An additional Increase of up to lfi%> over this 30# increase, is within possibility by closer control of the chlorine feed rate on Aroclor 1142. 3. The additional increase in feed rate on Aroclor 1154 is only 15#, and on Aroclor 1160 it would be less. The inability to continue the increase in chlorine pressure accounts for the reduced improvement. 4. Better dispersion of chlorine is not needed in the chlorination at high feed rates to obtain specification grade Aroclor. This report ami the information contbiw'! her.Jn is the property of MONSANTO Cii.'hiK'Al. COKi'ANY 0129898 HARTOLDMONOOQ4776 Report No. 2790 -2- RECCMMENPATIONS t It is recommended that the four unmodified chlorinatars be equipped with individual cyclone entrainment separators so that they may be operated at more rapid rates of chlorination, if the proposed increase in Aroclor production is to be carried out. 0l2'qb HARTOLDMONOOQ4777 Report 2790 -3- EXfERIMENTAL DATA! Notebook References - 74867-8, 74870-1, 74873, 74875-6, 74881, 74894-5, 77351-7, 77364-71, 0O5U-16 , 82604-6. CHLORINATION DATA! TABLE I REGULAR AROCLCR 1142 CHLORINATIONS NO. 5 CHLORINATOR AT INCREASED RATE, NOS. 3 AND 4 CHLQRINATCRS AT NORMAL RATE Charge Chlor. Time Avg. Rate, Chlor. Equivalent# to Before Run Chlorinator Lbs. Cl* Time, Chlor. Time, Chlor.1 Product Circulating, No. Date No. per Hr. Hrs. Hrs. Lbs. Pounds Hrs. 455 4/21/5I 307 10/24/51 389 l/H/52 377 +* 5/14/52 383* * 5/15/52 4 5 3 5 5 437 13.0 ---1 574 9.9 -- 4000 4000 7400 7100 4.3 3.8 378 13-5 15.0 3600 5900 -- 537 9.5 10.6 3600 7100 3.5 521 9.8 10.8 3600 7100 4.0 * The calculated tine that would have been required for the chlorination of a full charge of 4000 lbs. of biphenyl. These two runs are 1154 chlorinations on which the data are given through the 1142 stage as a basis of comparison far the experimental chlorinations in this chlorinatar. See Table II. 0129897 HARTOLDMONOOQ4778 .{epcrt No. 2790 -4- TABLEI II EXPERIMENTAL 1142 CHLCRINATIONS IN NO. 5 CHLQRINATCR Charge Avg. Rate, Chlor. Equivalent to Run Lbs. Cla Time, Chlor. Time, Chlor., No. Date Per Hr. Hrs. Hrs Lbs. 278 10/16/51 756 7.5 4000 303 10/25/51 515 11.0 -- 4000 341 11/20/51 568 10.0 -- 4000 293 3/25/52 639 8.0 8.9 3600 381 * 5/15/52 786 6.5 7.2 3600 Product, Lbs. -- 6500 5900 -- ~ Chlor. Time Before Circulating, Hrs. -- ---- -- 1.42 1.5 * 1154 Chlorinations, data taken only through 1142 stage. NOTE* Runs 278, 303, and 341 were carried out by the plant and data given to Research. Runs 293 and 381 were carried out in toe plant by research personnel. TABUS III REGULAR 1154 CHLORINATIONS AT INCREASED RATES Charge Avg. Rate, Chlor. to Chlor. Time Run Chlcr. Lbs. Cl, Time, Chlcr Product, Before Circulating, No. Date No. Per Hr. Hrs. Lbs. Lbs. Hrs. 799 10/25/51 5 819 10/30/51 5 977 12/20/51 6 671 505 545 12.2 16.2 15.0 3600 3600 3600 7400 -- -- 3.2 3-8 3.2 0129898 HARTOLDMONOOQ4779 Report No. 2790 -5- table iv EXPERIMENTAL 1154 CHLCKINATIONS Run No. Bate Chlor. No. Avg. Rate, Lbso Clg Per Hr* Chlor. Time, Hrs. Equivalent Chlor. Tim, Hrs. Charge to Chlor., Lbs. Product, Lbs. Chlor. Tijne Before Circulating, Hrs. 292 10/22/51 5 66 1/15/52 6 86 1/18/52 6 618 671 693 14-7 12.2 11.8 13.3 -- 4000 3600 3600 7700 7330 7440 _- 1.0 1.0 TABLE V AROCLCR OHLCRINATION RATES Aroclor 1142 1154 Operating Conditions .1 Regular plant operation < 2. Increased plant operation 2- Experimental operation p- Regular plant operation < 2. Increased plant operation 3. Experimental operation Avg. Rate, Lbs. Clj Per Hr. 410 545 770 415 575 660 % Increase Over Condition T-1----------2 ---- 33 -- 88 41 ---- 39 -- 59 15 q\29099 HARTOLDMON0004780 Report No. 2790 Data on Laboratory Distilled Aroclors from Rapid Chlorinationss -6- TABLE VI AROCLCR 1242 ANALYSES Property $ Recovery on Distillation Color , AFHA Condition Sp. Gr. at 25*C. Acidity Inorg. Cl., ppm. Viscosity, S.U.S. at 100'F. D. K. at 100*C. Resistivity} ohm-cm X 10-9 at 100PC* Ref0 Index at 25#C Pour Point,*C. Water, ppm. Dist. Range, *C. Corrected 10$ 50$ 90$ Corrosion Test Run Number 278 303 341 293 381 _ 96.7 20+ Clear 1.384 0.001 0.05 85.4 4-68 98.4 -----Clear 1.380 -- -- -- 4.80 95.0 25 Clear 1.378 -- -- -- 4.82 98.8 -- Clear 1.388 -- -- -- 4.86 98.4 35 Clear 1.390 0.001 0.05 89.8 4.89 11,000 1.6263 -18 86 5,700 1.6245 -- -- 1,400 1.6243 -- -- 4,500 -- -- -- 6,400 1.6253 -18 90 317 331 329 332 332 350 337 337 339 339 366 352 353 357 354 passes -- -- passes Control Specification r-- . 100 max. Clear 1.378-1.388 0.014 max. 0.1 max. 83 i 5 4-7-4.9 500 min 0 1.6245-1.6265 -14 max 35 maxB 0129900 HARTOLDMONOOQ4781 Report No. 2790 TABI VII AROCLCR 1254 ANALYSIS -7- Property Run Number 292 66 86 % Recovery in Distillation 97.6 Color, APHA Condition 45 Clear Sp. Gr. at 65'C. Acidity, Sfc|2SE 1.498 0.001 Xnorg. Cl., ppm. 0.05 Viscosity, S.U.S. at 98.9'C. 45-2 D. K. at 100*C. Resistivity, ohm-cm X 10"^ at 100*C. 4.23 12,000 Refractive Index at 25 *C. 1.6379 Pour Point, 'C. 8 Water, ppm. Evap. Loss at 100C., % 33 0.024 Distillation Range "C., observed 10* 354 50* 360 90* 370 Corrosion Test passes 96.3* 65 Clear -- -- -- -- -- 95 35 Clear 1.498 0.001 0.05 45-4 4-15 3,400 7,300 1.6380 -- 1.6387 8 -- 35 -- 0.032 355 360 371 -- 354 359 368 passes ^ No lime in distillation Control Specifications -- 100 max. Clear 1.495-1.505 0.01 max. 0.10 max. 44-47 4.15-4-35 7500 1.6370-1.6390 8-12 35 max. 0.4 max. 350-355 355-362 362-379 0127901 HARTOLDMONOOQ4782 Report No. 2790 -8- Graphs! Data far the curves, Graphs I, II, and III are tabulated as follows! GRAPH I SPECIFIC GRAVITY OF CHLORINATED BIPHENYL VS. % CHLORINE at 25*C. Sp. Gr. % Cl. 1.182 1.267 1.383 1.452 1.543 1.623 1.807 1.033** 21 32 42 48 54 60 68 0 a* 65*C* Sp. Gr. % Cl. 1.155 1.243 1.348 1.414 1.505 1.597* 1.773* 1.000** 21 32 42 48 54 60 68 0 * Estimated from 25*C. curve Extrapolated values for biphenyl 0129902 HARTOLDMONOOQ4783 Report No. 2790 GRAPH IX SPECIFIC GRAVITY VS. TOTAL CHLORINE FEED FOR 3600 LB. CHARGE OF BIPHENYL It can be shown that for chlorination of biphenyl - 9- - 0.972 X + 2 Y where X total weight of chlorine feed, pounds Y weight of biphenyl charged, pounds Z decimal fraction of chlorine in the product (i.e. for Aroclor 1254, Z - 0.54) Using this equation, and reading the % chlorine vs. specific gravity curve. Graph I, the following data are obtained for a 3600 lb. charge of biphenyl* % Chlorine 10 20 30 40 50 60 70 Sp. Gr. at 65 "C, 1.067 1.144 1.229 1.325 1.445 1.600 1.825 Total Weight of Chlorine Feed, Lbs. 797 1,788 3,050 4,710 7,010 10,360 15,740 0129903 HARTOLDMONOOQ4784 Report Ho. 2790 GRAPH III RATE OF CHLORINATION VS. TIKE CHLCRINATCR NO. 6 AROCLQR 1154 REGULAR RUN 977 -10- Time Elapsed, Hr. Specific Gravity at 65*C. 0 1.58 2.58 3.58 4.58 5.58 7.08 8.08 9.08 10.08 11.08 12.08 13.08 14.33 15.00 Average Rate 1.000 1.068 1.092 1.129 1.172 1.202 1.272 1.312 1.333 1.368 1.416 1.430 1.475 1.485 I.5O6 Cumulative Wt. of Cla Feed, Lbs. ____ _ 800 1,100 1,600 2,200 2,650 3,750 4,430 4,800 5,450 6,360 6,650 7,630 7,840 8,300 Increase in Cla, Lbs. 800 300 500 600 450 1,100 680 370 650 910 290 980 210 460 Avg. Rate per Interval, Lbs. Cl2 Feed Per Hr. C'l3 Back Pressure Psig. _______ 506 300 500 600 450 734 680 370 650 910 290 980 168 687 553 14 15 15 20 20 20 25 25 25 25 25 25 28 28 28 HARTOLDMONOOQ4785 Report No. 2790 AROCLQR 1154 EXPERIMENTAL RUN 66 -11- Time Elapsed, Hrs. Specific Gravity at 65C. 0 1-5 2.0 3.0 4*0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 12.17 Average Rate 1.000 1.060 1.078 1.120 1.160 1.209 1.246 1.285 1.316 1.361 1.403 1-445 1.490 1.498 Cumulative VTt. of Cl3 Feed, Lbs. ____ 700 930 1,470 2,030 2,760 3,340 3,980 4,500 5,300 6,120 6,980 7,950 8,150 Increase in Cl*, Lbs. -. . 700 230 540 560 730 580 640 520 800 820 860 970 200 Avg. Rate Per Interval, Lbs. Cl2 Feed Per Hr. .- 466 460 540 560 730 . 580 640 520 800 820 860 970 1,177 670 Cla Back Pressure, Psig. 16 18 20 20 24 24 28 28 32 32 32 35 35 35 0129906 HARTOLDMONOOQ4786 Report Mo. 2790 -12- AROCLCR 1154 EXPERIMENTAL RUN 86 Time Elapsed, Hrs. Specific Gravity at 65'C. 0 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 11.75 Average Rate 1.000 1.070 1.087 1.130 1.168 1.215 1.255 1.296 1.333 1.378 1.420 1.467 1.500 Cumulative Wt. of Cla Feed, Lbs. Increase in Cl,, Lbs. Avg, Rate Per Interval Lbs. Cla Feed Per Hr. ____- 830 1,030 1,600 2,150 2,850 3,490 4,150 4,810 5,630 6,470 7,650 8,180 _____ 830 200 570 550 700 640 660 660 820 840 1,180 530 _____ 553 400 570 550 700 640 660 660 820 840 1,180 707 696 Clj Back Pressure, Psig. 16 18 18 20 22 24 26 28 30 32 34 34 34 Ol^06 HARTOLDMONOOQ4787 t SPECIFIC GRAVITY PER CENT CHLORINE 01F9907 HARTOLDMONOOQ4788 % CHLORIDE TOTAL WEIGHT OF CHLORINE FEED, SPECIFIC GRAVITT AT 65'C. 0129908 HARTOLDMONOOQ4789 FEED RATE, POUNDS OF CHLORINE PER HOUR o HARTOLDMON0004790 Report No. 2790 -13- DISCUSSIONi Chlorlnators 5 and 6 have been modified far rapid chlorination by installation of small individual cyclone entrainment separators with return lines to the chlorlnators. Normal plant operation in these two chlorlnators is faster than in the unmodified chlorlnators, but observation of the plant operations indicated that tha time of chlorination might be even further reduced by better control of chlorination rates throughout the chlorination. Graph III of this report shows the rate curve for a normal plant chlorination, Run 977, which is typical of the rate curve for usual plant operation. The rate of chlorination starts low, builds up in excess of 700 to 800 pounds per hour toward the middle stage, sometimes greater than 1000, and then decreases toward the end. This behavior results from Inadequate control of the chlorine pressure being supplied to the chlorinator. It seemed apparent that by controlling the chlorination more closely to give more uniform rates, considerable time might be saved during a chlorination. Two experimental plant runs were made during which the chlorine was admitted at a faster rate throughout the run. Chlorinator 6 was chosen for these tests because it is one of two chlarinators equipped with small individual entrainment separators as well as the large cyclone separators. Chlorlnators 1, 2, 3, and 4 are equipped with the large separa tors only. The first test run. No. 66, required twelve hours and ten minutes to complete the ohlorination. The chlorine was admitted at an Initial back pressure of sixteen pounds and after gradual increases for the first several hours, the pressure was Increased four pounds every two hours until a final pressure of thirty-five pounds was reached. This pressure was maintained at thirty-five pounds for one hour and ten minutes with no appar ent difficulty. The second test run, No. 86, required eleven hours and forty-five minutes. This run was started at an initial chlorine pressure of sixteen pounds; however, during this test, the pressure was increased two pounds every hour until a maximum pressure of thirty-four pounds was attained. At the beginning of Run No. 66, the chlorine tank car was practically full, and during the run the pressure of the car decreased from 80 to 76 p.s.i.g. The only unusual observation was that the chlorine vapor linp coming out of the vaporiser turned cool when a back pressure of thirty-five pounds was reached. At the beginning of Run No. 86, the chlorine tank car was about half full, and while the pressure of the car remained constant throughout the run, the pressure was only 63 p.s.i.g. The maximum back pressure of thirty-four pounds could not be increased at the conclusion of the run. Circulation of the material in the chlorinator was started only one hour after chlorina tion was started. The usual plant procedure is to wait three or four hours; however, because chlorine was going in at a faster rate, circulation was starter earlier. The temperature of the chlorinator was easily maintained within the required operating temperatures of 105*C. to 150'C. 0129910 HARTOLDMONOOQ4791 Report No. 2790 -14- At the conclusion of each run, the trappings, or material collected by the cyclone separa tor, were drained. Material from chlorinators 3, 4, 5, and 6 totalled approximately onehalf of a 55-gallon drum. This was considered normal by the operator. Graph III also shows the rate curves for these two experimental chlorinations. There appears to be little difference in raising the pressure four p.s.i.g. every two hours, and in raising it two p.s.i.g. every hour. Both of these runs started at about 500 pounds of chlorine per hour, gradually increasing toward the middle of the run, and then entered a somewhat greater upward trend toward the end of the run. These curves of course show only the general trends in the rates. There is still considerable variation, but not as wide as in the regular runs. Tfie reduced time of chlorination is adequate proof of the effectiveness of the method. Table III and Table IV show the detailed data for the 1154 chlorinations, both regular and experimental operation. Table V shows the averages of the chlorination rates under the various conditions and gives the percentage increases in each case. An increase of nearly 60$ was realized in the experimental Aroclor 1154 chlorinations over the regular plant operations. An increase of nearly 40$ has already been shown in plant operations on No. 6 chlorinator over operations on the unmodified chlorinators. Table VII gives the analyses of the Aroclors fran the experimental operations, all of which are within speci fications. Several experimental runs were carried out on Aroclor 1142 in chlorinator 5 Table I gives typical data for regular 1142 chlorinations as compared to the experimental chlor ination data given in Table II. Comparison of data in- these two tables shows that an increase of about 33$ in plant production has been brought about in chlorinator 5, and that a further increase of 41$ over this rate is possible, or a total overall increase of 88$. This comparison is tabulated in Table V. It should be pointed out, however, that this increase in production was accomplished on only one chlorinator, and that a similar increase on all the chlorinators would be largely dependent upon an adequate supply of chlorine to maintain these increased feed rates. Table VI gives the analyses of the Aroclor 1242 samples from the experimental 1142 chlor inations. All of these samples were within specifications except that from Run 278 which had an unusually wide distillation range. Runs 303 and 341 were made at lower rates of chlorination and gave satisfactory Aroclors. It was then thought that finer dispersion of the chlorine by a glass cloth might make possible more rapid rates without producing off-grade Aroclor. Run 293 was made with such a cloth over the chlorine dlstirbutor and specification grade Aroclor resulted) however, the rate of chlorination was not as Ugh as in Run 278. Subsequent examination of the glass cloth revealed that it had formed a matte-like material and had so constructed the flow of chlorine that the resulting pres sure had ripped the cloth at the seam. For this reason, it was considered entirely un satisfactory for this application. Furthermore, the data for Run 381 show that speci fication grade Aroclor 1242 can be produced at even a faster rate than enployed in Run 278, and without further modification of the equipment. This rate of 786 pounds of chlo rine per hour is the highest overall average rate yet attained in an experimental plant chlorination. It must then be concluded that the glass cloth is of no value in the chlo rinator, and that the wide distillation range obtained in Run 278 was not due to the rapid chlorination rate, but was probably due to Ugher chlorinated trappings being charged to the chlorinator. 0129911 HARTOLDMONOOQ4792 Report No. 2790 -15- From the foregoing facts it may be stated that an increase in production of about 30? has already been accomplished in the plant on No. 5 and No. 6 chlorinators, and that an addi tional increase of up to 40? over this 30? is within possibility depending largely upon the chlorine supply available. Although no specific test was run on Aroclor 1260, regular production during periods of fast chlorination rates was satisfactory. Theoretically, there is also less chance of varying the isomer distribution of the Aroclor 1160 then of the 1142. Therefore, any change in properties is unlikely in view of the successful Aroclor 1242 and 1254 tests. In consideration of the maintenance of equipment, the erosion of the distributor plate will be greater at the high chlorine feed rates. Observations have Indicated that the plates may last only about a third as long as at the slow feed rates of 400-500 pounds per hour. Increasing the number of holes in the distributor plate would help in lessening the erosion. The replacement of catalyst may also be a more frequent practice. At the higher feed rates, the chances of localized higp temperatures in the reaction zone are good and will allow more iron chloride to be formed, thus using up the iron turnings at a faster rate. be 7-22-52 0129912 HARTOLDMONOOQ4793