Document J3qN6a66kZ189pdx3k6dbL9RB

? Material Safety Data Sheet Required under USDL Safety and Health Regulations % tor Shipyard Employment (29 CFR 1915) U.S. Department of Labor Occupational Safety and Health Administration PLAINTIFF'S,, OMB No. 1218-0074 Expiration Date 05/31 /86 Section 1 Manufacturer's Name LAC D`AMIANTE DU QUEBEC, LTEE Address (Number. Street. City. State, and ZIP Code) P.0. Box 608 Black Lake, Quebec, Canada 60N 1A0 Section II - Hazardous Ingredients Emergency Telephone Number Chemical Name and Synonyms Trade Name and Synonyms Hydrated Magnesium Silicate Chrysotile asbestos fibre ~ -- 3W-2Si02-2H20 Painta, Preservatives, and Solvents Pigments - Not applicable (NA) Catalyst it % TLV (Units) Alloya and Metallic Coatings Base Metal Alloys . Vehicle Metallic Coatings ii Solvents ii ' Filler Metal Plus Coating or Core Flux Additives ii Others Others ii Hazardous Mixtures ol Other Liquids, Solids or Gases Chrvsotile Asbestos (Min.) 95% 2 fibres/cc* * nv (Units) NA ii n " n - % TLV (Units) * Onlv fibres areater than 5 micrometres in lenqth. 0SHA ceiling concentratio is * 10 fibres/cc (>5 pm). See 0SHA regulation 29CFR1910.1001 for additional req lire nents. Section III - Physical Data Boiling Point (*F) Specific Gravity (H,0*1) NA 2.4-2.6 Vapor Pressure (mm Hg.) . Percent Volatile by Volume (%) NA NA Vapor Density (AIR1) Evaporation Rate NA i) NA Solubility in Water __________ insoluble Appearance and Odor __________ odorless, white fibrous form Section IV - Fire and Explosion Hazard Data Flash Point (Method Used) Flammable Limits' Lei Uel nonflammable NA Extinguishing Media ___ m Special Fire Fighting Procedures Wear NIOSH/MSHA approved self-contained breathing apparatus and protective clothing. Unusual Fire and Explosion Hazards None Page 1 (Continued on Reverse Side) JIM. 2 4 1985 D 004138 Form OSHA-20 (Rev. 3/84) Section V - Health Hazard Out '~ _______________________________ ThreshQ'a Limit Value Effects of Overexposure (see Section II) Chronic inhalation of asbestos may cause symptoms of variable cough, dispnea. chest pains, weakness and decreased chest expansion. Later findings may include asbestosis -- a diffuse but non-uniform fibrosis of the lungs, and respiratory cancer. Emergency First Aid Procedures None specific, remove from exposure and see an occupational physician. ___ Section VI Reactivity Data Stability Unstable Conditions to Avoid Stable X Incompatability (Materials to Avoid) None Hazardous Decomposition Products . None Hazardous Polymerization May Occur Will Not Occur X Conditions to Avoid - - Section VII - Spill or Leak Procedure* Steps to be Taken in Case Material is Released or Spilled , A clean-up procedure (i.e. vacuuming or wetting) which minimizes exposure is required. Place all 'material in closed containers with approved labels. If the possibi hty of dust exposure exists, wear NIOSH/MSHA approved respiratory protection (see below). Waste Disposal Method -~ Dispose of material in accordance with all Federal, State and local vair pollution, water pollution and solid waste regulations. Recommend disposal in an EPA approved hazardous waste landfill.i Section VIII - Special Protection Information Respiratory Protection (Specify Type) NIOSH/MSH A approved for toxic dusts or asbestos (see below) Ventilation - Local Exhaust Special Reauired (see below) Mechanical (General) Other i Protective Gloves Required (see below) Eye Protection Recommended omer Protective Equipment Protective clothing is required if exposures exceed the OSHA ceiling limit nr cignifirant, rnntart occurs . Remove all work clothing before .leaving plant prpmisP-S.-- Section IX - Special Precaution* precautions to be Taken m Handling and storing Local exhaust ventilation, material wetting and/or respiratory protection is required for all sawing, grinding, cutting, bulk handling, spraying, demolition, removal or other activities where dust exposure may occur. omer Precautions inhalation or ingestion of dust. Do not smoke. Practice good housekeepir and personel hygiene procedures. Avoid asbestos dust becoming airborne and remove spillac by vacuuming loose fibre or wetting before clean-up. Do not dry sweep. Repair damaged vacuum haos immediately. Place all material in closed containers properly labelled Pag* 2 O 004139 Form OSHA-20 (Rev. 3/84) Andri Gauthier Vice-president senior Operations IAQ June 13, 1985 Mr. E.E. Wang J-M Manufacturing Company, Inc. 1051 Sperry Road, Stockton, Cal. 95206 Dear Sir: Further to your request, please find enclosed Material Safety Data Sheet for chrysotile asbestos fibres, grades 5R3 and 4T3. Please do not hesitate to contact the undersigned if any other information is required. /dbm Enel. 1 cc: DWilkinson - Stockton BCiaccio - Denison File Yours truly A. Gauthier Lac d'Amiante du Quebec, Lt6e Black Lake, Quebec, GON 1AO (418) 423-4221 Cable LAQBESTOS BLACK LAKE T6lex 05-833586 JUN. 241985 D 004140