MONSANTO COMMENTS ON THE ANALYTICAL METHOD SPECIFIED IN THE PROPOSED TOXIC POLLUTANT EFFLUENT STANDARDS FOR POLYCHLORINATED BIPHENYLS
. The analytical method specified in the Proposed Standards
is unsatisfactory for measuring PCBs at water concentrations
*
'
"
approaching 1 pg/1. At higher concentrations the method may
have adequate specificity and accuracy for monitoring
effluents. It has the inherent sensitivity to detect and
measure PCB levels below 1 pg/1. However, at PCB concentra
tions of about 1 pg/1 the precision and accuracy of the
method, when applied to actual industrial effluents, has
not been demonstrated. The method has not been subjected
to adequate multi-laboratory testing to define the accuracy.
precision or limits of applicability. Multi-laboratory
i
round robin testing of the precision of a similar method,
i
American Society for Testing Materials Method D-3304,
t
"Analysis of Environmental Materials for Polychlorinated
1
Biphenyls," has been carried out. This test by twelve
t
laboratories showed that the 95% confidence level for
' precision agreement between any two participating laboratories
was greater than a factor of two. Using the ASTK method,
the only method subjected to government and industrial multi
laboratory testing, if one laboratory measures PCB in a
sample containing only PCBs and water and reports a value^ of
1.0 pg/1, a second laboratory could expect to measure a
'
\
%
,
a unit o Monaanto Company
0Z89`'9
.
PCB-ARCH0746935
000000085.00000
-2-
valua in the range of about 0.5 to 2.0 pg/1. This precision
variability very likely applies also to the method specified
in the Toxic Pollutant Effluent Standards. However, if you
are trying to measure PCBs in an industrial effluent you
would not be able to achieve the sensitivity or reproducibility
reported in ASTM^3304. The accuracy of neither method has
been adequately testing in industrial effluents.
Since the precision and accuracy of the recommended method
for real effluents are unknown, this uncertainty should be
reflected in the Proposed Standards.
An abbreviated procedure is needed for.routine monitoring
of PCBs at the sources covered by the Proposed Standards,
namely PCB manufacturers and capacitor and transformer
manufacturers. Effluents from these facilities typically
have a very low ratio of pesticides to PCBs. Potential
interferences likely to be in these effluents are not
pesticides and are not materials classified as toxic
pollutants. Therefore, we propose that these facilities
should be allowed to use a straightforward procedure
designed to measure only PCBs.
The method specified in the Proposed Standards is not
such a procedure. It contains elaborate and time-consuming
separation schemes to isolate each potential interference
and permit its measurement. However, as pointed out above,
this is beyond the scope of the Toxic Pollutant Effluent
Standards and represents an undue hardship for those*moni
toring source effluents.
V
0Ze84b0
PCB-ARCH0746936
000000085.000002
-3-
We propose ASTM Method D--3304 as an alternate procedure for these source effluents. This method was developed specifically for PCBs and omits the elaborate separation procedures for organochlorine pesticide interferences. Instead, pesticides and many other potential interferences
are eliminated by a simple chemical treatment. Hence, the method is more direct, less prone to handling errors and
less time-consuming.
The following specific comments apply to the EPA method:
1. The method title should be changed to reflect the
intended dual application of this method to PCBs and
organochlorine pesticides.
2. When the observed PCB level is significantly above
laboratory and reagent background, background sub
traction should be permitted.
,
3. In Section 4.1, reference to a glass lined injection port should be rephrased to insure that it includes on-column injection into glass columns.
4. Acetonitrile partitioning similar to that described in Section 10.2 leads to incomplete recovery of PCBs as well as pesticides. Recoveries of various PCB product mixtures during this partitioning should be carefully examined.
5. Confirmation of PCBs using the second GC liquid phase referenced in Section 4.4.4.2 should be clarified 'in
the experimental portion of the method.
>
6. Total peak areas should be used for quantitation of
each PCB product mixture. This technique is equally accurate and much more rapid than using peak weight
factors for calculating effluent concentrations. '
0288961
-
PCB-ARCH0746937
000000085.000003
-47. Chromatograms of Arcelor 1016 should be included with
the reference chromatograms of the other PCB products. Sampling and sample storage procedures are even more important than the analytical method for establishing accurate effluent concentrations. Random "grab" samples, for example, are inadequate for determining daily or monthly average concentrations. Improper sampling or storage can introduce order of magnitude errors in measured concentration values. Proposed Standards and the analytical method specified therein completely ignore sampling and storage. It is important ijhat samples be representative of the average t effluent and be properly preserved. Accordingly the Standard must specify precisely how samples are to be obtained. It must also impose limitations on sample storage conditions, including containers.