Document J3mYELdqaa57b7EZLwey5OLXv
O AMERICAN STANDARD
trade price book for
AMERICAN-STANDARD
Hydronic Heating Equipment*
Hvdromcs the science of heating and cooTing with water `
_________________ PRODUCTS________________
Boilers -- Cast Iron
Electric Packaged Boilers
Gas
Packaged Units
Boilers
Electronic Control Systems
Oil Packaged Units
Boiler-Burner Units
Flame Retention Boiler-
Burner Units
Boilers
Oil Pressure Fired
Gas Boiler-Burner Units
Gas-Oil____________________________________
Coat Stoker Fired
Hand Fired
Oil Burners and Controls Comfort Computer --
Zone ViWe Packages
Hydronic Assembling Tools Radiation:
Baseboard Panels Heatnm
Baseboard Panels. Radiantrim
Radiators
Arco, Sunrad
Convectors
Muttifin
Arco
Cabinet Extras
Terms General Information Repair Parts Discounts
Memorandum
PAGE
39-40 2-6, 9 7, 8, 10-16 17 18-19 20, 22-30, 33
29, 30 21.22, 28, 31 -33. 36,37
23-28
36 37____ 33, 35
34 38
41-44 45 45 46-48 49 50___ 56 51 51____ 52-55
02401
PACKAGED boilers GAS FIRED WATER
fS\ AMERICAN
kS STANDARD
HYDRONIC HEATING
GPMX PACKAGED GAS BOILERS
Completely factory assembled and pre-wired. Two-toned brown and beige jacket encloses all controls. Regularly supplied for 115 volt 60 cycle power supply with 24 volt system; self ener
gizing controls when specified at no extra charge. Built-in purge valve--Patent applied for. Built-in air separator, in left-hand end section. Intermittent circulator operation.
Design certified by A. G. A. for combustible floor and closet installations. Cast iron drilled port burners are standard equipment for natural gas. Ribbon burners are standard for propane gas -- optional for natural gas at 10% reduc
tion of rating as indicated by model number suffix R. Tested and equipped for 30 lbs. water working pressure. Ratings shown are for installation at sea level and up to 2,000 feet.
WATER -- for natural gas -- 100% shut-off
pockoged boiler number
GPMX-3 GPMX-4 GPMX-5 GPMX-6 GPMX-7 GPMX-8
A G.A input Mbh
66 99 132 165 198 231
A.G.A. output Mbh
52.8 79.2 105.6 132.0 158 4 184.8
nel l = ft rating
Mbh
46.1
68.7
92.2
114.8 137.4
160.9
net rating
tq ft water
Trade Price with
standard equipment
307 458 615 765 916
____10_7_3 ___
$310.00 339.00 387.00 442.00 496.00 550.00
approx chipping weight
197 240 284 335 381 428
| chimney me
mtide i diam. m
;4
;5 5 6 7 7
heighr feel
10 10 10 10 10 10
WATER -- for propane gas-- 100% shut-off
GPMX-3R GPMX-4R
GPMX-5R GPMX-6R GPMX-7R GPMX-8R
60 90 120 150 180 210
48 72 96 120 144 168
41.7 62.6 83.5 104.3 125.2 146.1
278 $310.00 417 339.00 557 387.00 695 442.00 835 496.00 974 550.00
197 240 284 335 381 428
4 5 5 6 7 7
10 10 10 10 10 10
Ordering Examples:
1. Pockoged boiler with ttandord equipment: 1 GPMX-6 boiler with 24 volt control) Not. gat, 1000 Btu, .6 tg.
2. Pockaged boiler with optional equipment: 1 GPMX-7R boiler with 24 volt controlt for constant circulator operation. Nat. gas, 1000 Btu, .6 ig. 1 conversion kit from natural to propane gas
Standard Equipment
V81 series manifold gas valve includes main operator, manual shut-off,
pilot filter, pressure regulator (except for propane gas) and Pilotstat.
1XA" Circulator with Piping Drain valve ASME relief valve, 30 lb.
Draft Hood Wiring Harness Purge Valve
Expansion Tank Auto Air Vent Automatic Fill Valve
Specify 24 Volt . . . or . . . Specify Self Energizing
T822D thermostat
T822D thermostat
L4080D limit control
L8148G limit and circulator relay (40VA)
R8226B transformer (40VA)
and circulator relay
Note: Boiler is shiDDed with jacket, all controls, circulator, main burners and manifold controls and piping factory installed and wired. Purge valve, air vent and expansion tank installed. Relief valve and thermostat fastened
inside boiler crate. Draft hood shipped separately.
Optional Equipment
Optional constant circulation (24 V) L4081B limit and reverse acting circulator controls with AT20Dtransformer instead of L4080 and R8226B. Furnished at no additional charge.
Optional constant circulation (S.E.) L4081B limit and reverse acting circulator control and TS822A thermostat instead of L8148G and T822D thermostat. Furnished at no additional charge.
Conversion Kits: Boilers must be specified with suffix letter R. Reduced propane ratings apply.
Natural to Propane gas Propane to Natural gas
Trade Price $6.50 Trade Price $6.50
Zone valve packages are available for water boilers. For details and prices, see page 34.
HH-11 See page 56
Page 2
02402
rsiAMERICAN LSJSTANDARD
HYDRONIC HEATING
PACKAGED BOILERS
gas fired
WATER
GPM PACKAGED GAS BOILERS
Completely factory assembled and pre-wired. Two-toned brown and beige jacket encloses all controls. Regularly supplied for 115 volt 60 cycle power supply with 24 volt system; self ener
gizing controls when specified at no extra charge. Built-in purge valve--Patent applied for. Built-in air separator, in left-hand end section. Intermittent circulator operation.
Design certified by A. G. A. for combustible floor and closet installations. Cast iron drilled port burners are standard equipment for natural gas. Ribbon burners are standard for Propane gas -- optional for natural pas :ti IO'/t reduction of rating as indicated by model number suffix R. Tested and equipped for 30 lbs. water working pressure. Ratings shown are for installation at sea level and up to 2,000 feet.
WATER--for natural gas--100% shut-off
pockoged boiler nvmber
GPM-3 GPM-4 GPM-5 GPM-6 GPM-7 GPM-8
1 AGA 1 mpwi
| Mbh
| 66
! 99
! 132
165 1 198
231
AC.A Mbh
52.8 79.2 105.6 132.0 158.4 184.8
net
rolmg Mbh
46.1 68.7 92.2 114.8 137.4 160.9
------------- !
net roting
tq fl wettr
^^Trode Price with
ilandard equipment
307 458 615 765 916 1073
$287.00
317.00 366.00 421.00 475.00 529.00
approx ihipping weight
200 240 285 335 385 430
chimney me
inudc
height
foot
'5
i5 6
7 7
10 10 10 10 10 10
WATER--for propane gas--100% shut-off
' GPM-3R GPM-4R GPM-5R GPM-6R GPM-7R GPM-8R
60 90 120 150 180 210
48 72 96 120 144 168
41.7 62.6 83.5 104.3 125.2 146 1
278 417 557 695 835 974
$297.00 317.00 366.00 421.00 475.00 529.00
200 240 285 335 385 430
4 5 5 6 7 7
10 10 10 10 10 10
Ordering Examples: 1 Packaged boiler with ilandard equipment' I GPM-5 boiler with 24 volt controls Nat. gas, 1000 Btu, .6 sg 2 Packaged boiler with optional equipment. 1 GPM-3R boiler with self-energizing con trols for constant circulator operation. Propane gas
See page 56
Standard Equipment
V81 series manifold gas valve includes main operator, manual shut-ofF.
pilot filter, pressure regulator (except for Propane gas) and Pilotstat.
1%" Circulator with Piping Draft Hood
Drain valve
Wiring Harness
ASME relief valve, 30 lb.
Purge Valve
Specify 24 Volt . . . or . . . Specify Self Energizing
T822D thermostat
T822D thermostat
L4080D limit control.
L8148G limit and circulator relay (40VA)
R8226B transformer (40VA)
and circulator relay
Note: Boiler is shipped with jacket, all controls, circulator, main burners and manifold controls and piping factory installed and wired. Relief valve and Thermostat fastened inside boiler crate. Draft hood shipped separately.
Optional Equipment
Optional constant circulation (24 V) L4081B limit and reverse acting circulator controls with AT20D transformer instead of L4080 and R8226B. Furnished at no additional charge.
Optional constant circulation (S.E.) L4081B limit and reverse acting circulator control and TS822A thermostat instead of L8148G and T822D thermostat. Furnished at no additional charge.
Conversion Kits: Boilers must be specified with suffix letter R. Reduced Propane ratings apply.
Natural to Propane gas Propane to Natural gas
$6.50 $6.50
Zone valve packages are available for water boilers. For details and prices, see page 34.
Page 3
HH-11
02403
PACKAGED BOILERS GAS FIRED WATER
rS! AMERICAN LSJstandard
HYDRONIC HEATING
G-2 PACKAGED GAS BOILERS
Fully packed, pre-wired, and equipped with controls for forced circulation, the G-2 is a quality, time-proven cast iron gas fired boiler available with and without tankless heater for domestic water requirements.
This modern deluxe jacketed boiler features the patented "Eliminaire" (cast-in air sep arator in the left end section) and the distinctive American-Standard brown and beige jacket color combination to dress up any basement or utility room.
The boiler is tested and equipped for 30 lbs. water working pressure and i= regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system Self-eneigizing controls are avalable without extra cost.
Ratings shown are for installation at sea level and up to 2,000 feet.
WATER--for natural and propone gases--100% shut-off
packaged number
A.G.A. Input Mbh
A.G.A.
output Mbh
tankless heater
number
t=:W=H
rating
net l=B=R rating
Mbh
net rating sq ft water
Trade Price with standard
equipment
epprox.
shipping weight
chimney size inside height diam. in. feet
Packaged boilers with factory installed tankless heater
G-24-DPT G-25-DPT G-26-DPT G-27-DPT
90
120 150 180
72 96
120 144
Packaged boilers less heater
218 222
222 222
2 Vi 62.6 3 83.5 3 Vi 104.3 3 Vi 125.2
417
556 695 834
$466.00 521.00 573.00
620.00
416 481
551 620
5 10 5 10 6 10 6 10
G 23-DP G-24-DP G-25-DP G-26-DP G-27-DP
60 48 90 72 120 96 150 120 180 144
41.7 62.6 83.5 104.3 125.2
278
417 556 695 834
$367.00 431.00 482.00 534.00 581.00
333 403 472 542 603
4 10 5 10 5 10
6 10 6 10
AGailono of waier per minute heated Iron 40F to 140F with 2QQF boiler water temperature.
Standard equipment
V-81 Series manifold gas valve including mam operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat.
1 % " Circulator with piping ASME relief valve Draft hood (for G-23 only, shipped
m separate carton)
Pressure and temperature gauge Wi rine harness
AT20D transformer (24V. less heater boilers only)
Additional standard equipment for boilers with heater
Tankless heater as listed above T822D (24V.) thermostat L8124E (24V.) or L8124B (S.E.) triple Aquastat relay
Ordering Examples: 1. Packaged boiler less heater with standard
equipment 1 C-24-0P boiler Nat. gas, 1000 8tu, .6 sg.
2. Packaged boiler with factory installed heater
with optional equipment: 1 G-26-DPT boiler with ribbon burners and
Nat to Propane conversion kit. Nat. gas, 1000 Btu, .6 $g.
Additional standard equipment for boilers less heater
T822D (24V.) or TS822A (S.E.) thermostat L4081B (24V. and S.E.) combination high limit and circulator control Note: Left hand end section less tankless heater opening
Note: Shipped with jacket, all controls (except thermostat), circulator and piping, main burners and manifold controls and piping factory installed and wired. Thermostat, manual main gas and pilot gas shut-off valves
and relief valve shipped in accessory box fastened inside boiler crate.
Optional equipment
Self-energizing controls (consist of VS81 Series gas valve, TS822A ther
mostat, Q313 Thermopile Generator and limit or combination control as
noted above), available when specified on order
no charge
L8148E (24V.) or L8148G (S.E.) combination limit/relay in lieu of
L4081B furnished on G-2 DP boilers
no charge
Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit":
order ................................................ G-23 thru G-27 ''Trade Price $5.70
Floor shield for combustible flooring. Add suffix letter "C" to boiler number add $3.30
Note: in areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above.
Zone valve packages are available for water boilers. For details and prices, see page<34.
HH-i i "W See page 56
Page 4
02404
PEI AMERICAN Si STANDARD
HYDRONIC HEATING
PACKAGED BOILERS GAS FIRED STEAM
G-2 PACKAGED GAS BOILERS
For steam installation on new work or modernization, the G-2 Pack aged Steam boiler is available with either Flush or Deluxe jacket in the smart and attractive brown and beige combination that labels it an American-Standard top performing cast iron boiler.
This model is factory assembled and pre-wired for 115 volt, 60 cycle power supply with 24 volt control system. Where required, self-energizing controls are furnished without extra charge.
Ratings shown are for installations at sea level and up to 2,000 feet.
STEAM--for natural and propane gases--100% shut-off
packaged boiler
number
A.G.A.
Input Mbh
A.G.A.
output Mbh
net l=B=R rating
Mbh
sq ft
Trade Price with standard equipment
flush Jacket
deluxe Jacket
approx. shipping
weight
chimney size
inside diem. In.
height feet
G-23-SP* G-24-SP* G-25-SP* G-26-SP* G-27-SP*
60 48 90 72 120 96 150 120 180 _ 144
36
150
$308.00
$324.00
310
54 225 373.00
389.00
376
72
300
428.00
444.00
443
90
375
481.00
497.00
518
108 450
527.00
543.00
581
4 10 5 10 5 10 6 10 6 10
Add suffix letter "F" for flush or D" for deluxe jacket
Ordering Examples: 1. Packaged boiler with standard equipment: l G-26-SP0 boiler Nat. gas, 1000 8tu, .6 sg. 2. Packaged boiler with optional equipment: 1 G-24-SPD boiler with self-energizing con trols Nat. gas, 1000 Btu, .6 sg.
Standard equipment
V81 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat.
No. 67-GAR (24V. and S.E.) low water cut-off
Gauge glass with trimmings Draft hood (for G-23-D and G-23-F
thru G-27-F, shipped in separate carton) T822D (24V.) or TS822A (S.E.) thermostat
PA404A (24V. and S.E.) pressure limit control
AT20D transformer (except S.E.) ASME safety valve Steam gauge Floor pan and radiation shield
Note: Shipped with jacket, all controls (except those noted below), main burners and manifold controls factory installed and wired. Thermostat, low water cut-off, manual main and pilot gas shut-off valves (when required), safety valve and steam limit control shipped in accessory box fastened inside boiler crate.
Optional equipment
Self-energizing controls (consist of VS81 Series gas valve; Q313 Thermo
pile Generator; thermostat and limit control as noted above) available
when specified on order
no charge
No. 101-24V. electric water feeder is available for addition to the No.
67-GAR to provide a low water cut-off and feeder combination control
add $55.80
Natural to Propane gas conversion kits. Order boiler "with ribbon burners"
and "Natural to Propane conversion kit":
G-23 thru G-27
Trade Price $5.70
Note: ln areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above.
For Additional Optional Equipment, See page 15.
' See page 56
Page 5
HH-11
02405
PACKAGED BOILERS GAS FIRED WATER
d AMERICAN STANDARD
HYDRONIC HEATING
G-2 PACKAGED ALL-PURPOSE GAS BOILERS
Versatile and packed with pluses. Can be used for forced circulation or gravity installations. Completely factory assembled, pre-wired and crated with Deluxe brown and beige style leading jacket. Patented "Eliminaire" ends air problems.
Tested and equipped for 30 lbs. water working pressure and regularly fur nished for 115 volt, 60 cycle power supply with 24 volt control system. Self energizing controls available at no added charge.
Ratings shown are for installation at sea level and up to 2,000 feet.
WATER--for natural and propane gases--100% shut-off
packaged boJIer
number
A.OA.
Input Mbh
A.G.A. output
Mbh
nt IsBsR
rating Mbh
net rating
sq ft water
Trade Price with
standard equipment less thermostat
G-23-DPG
60
48
41.7
278
$269.00
G-24-DPG
90
72
62.6
417
335.00
G-25-DPG
120
96
83.5
556
393.00
G-26-DPG
150
120
104.3
695
447.00
G-27-DPG
180
144
125.2
834
494.00
approx. shipping weight
chimney size
Inside diam. in.
height feet
307 373 438 511 574
4 10 5 10 5 10 6 10 6 10
Ordering Eximples: 1. Packaged all-purpose boiler with standard equip ment: 1 G-25-OPG boiler Nat. gas, 1000 Btu, .6 $g. 2. Packaged all-purpose boiler with optional equip ment: 1 G-26-DPG boiler with self-energizing controls Nat. gas, 1040 Btu, .65 sg.
HH-11 See page 56
Standard equipment
V81 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat.
L4080B (24V. and S.E.) immersion limit control
ASME relief valve Pressure and temperature gauge
AT20D transformer (except S.E.) Draft hood (for G-23-DPG only
shipped in separate carton)
Note: Shipped with all controls, main burners and manifold controls factory installed and wired. Manual main gas and pilot gas shut-off valves (when required) and relief valve shipped in accessory box fastened inside boiler crate.
Optional equipment
Self-energizing controls (consist of VS81 Series gas valve; Q313 Thermo pile Generator and limit control as noted above) available when specified on order......................................................................................................no charge
Natural to Propane gas conversion kits. Order boiler with "ribbon burners"
and "Natural to Propane conversion kit":
Trade Price $5.70
Note: in areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above.
Thermostats for 24V. and S.E. control systems are available. For prices see page 35.
Zone valve packages are available for water boilers. For details and prices, see page 34.
Page 6
02406
^AMERICAN olSTANDARD
HYDRONIC HEATING
boilers-gas fired WATER AND STEAM
G-2 NON-PACKAGED ALL-PURPOSE GAS BOILERS
As a water boiler, this model is available with or without tankless coil for domestic water needs. With steam trim it is a top notch modernization item. Two jacket stylesFlush or Deluxe-this line is available in nine (9) sizes with factory assembled sections
Featuring the patented "Eliminaire" cast-in air separator in left end section, the boiler is tested and equipped for 30 lbs. water working pressure, 15 lbs. steam and is regularly furnished for 115 volt, 60 cycle power supply with 24 volt control sys tem. Self-energizing controls are available without extra charge.
Ratings shown are for installation at sea level and up to 2,000 feet.
WATER--Natural and Propane Gases--(Available with factory installed Tankless heater, see options, pages 15 & 16) --100% shut-off.
boiler number
A.G-A. Input
Mbh
A.GA. output
Mbh
net l=B = R
rating
Mbh
net rating
sq ft water
Trade Price with standard equipment
less thermostat
flush jacket
deluxe jacket
approx. shipping
walght
chimney size
inside diam. in.
height feet
G-23--W G-24-*W(T)
G-25-*W(T) G-26-*W(T) G-27-*W(T) G-28-*W(T) G-29-*W(T) G-210-WCO G-211-*W(T)
60 90 120
150 180 210
240 270 300
48 41.7 278 $242.00 $258.00
72
62.6
417
307.00
323.00
96
83.5
556
366.00
382.00
120 104.3
695
420.00
436.00
144 125.2
834
466.00
482.00
168 146.1
974
520.00
536.00
192
167.0
1113
216
187.8
1252
240 208.7 1391
573.00
620.00 673.00
589.00 636.00 689.00
295 353 426
500 566 630
699 790 863
4 5 5
6 6 7
7 7 7
10 10 10
10 10 10
10 10 10
Substitute letter`T*'for flush or "D" for deluxe jacket. Suffix "T" denotes forced circulation boiler equipped with factory Installed tankless heater (see page 16 for added charge).
STEAM--Natural and Propane Gases--100% shut-off.
boiler number
A.G.A. input
Mbh
A.G.A.
output Mbh
net l=B=R rating
Mbh
sq ft
W' Trade Price with standard equipment
lest thermostat
flush jacket
deluxe jacket
approx. shipping
weight
chimney size
Inside diam. in.
height feet
G-23--S G-24--S G-25--S
60 48 36 90 72 54 120 96 72
G-26--S G-27--S G-28--S
150 120
90
180 144 108
210 168 126
G-29--S
240 192 144
G-210--S 270 216 162
G-211--S 300 240 180
Substitute letter "F" for flush or "D" for deluxe jacket.
150 225 300
375 450 525
600 675 750
$285.00 351.00 409.00
463.00 509.00 564.00
616.00 663.00 716.00
$301.00 367.00 425.00
479.00 525.00 580.00
632.00 679.00 732.00
310 368 442
517 583 648
718 809 883
4 5 5
6 6 7
7 7 7
10 10 10
10 10 10
10 10 10
Standard Equipment
V81 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat.
Ordering examples: 1. Non-packaged all-purpose water boiler with standard equipment and flush jacket; 1 G-27-FW boiler Nat. gas, 1000 Btu, .6 sg. 2. Non-packaged all-purpose water boiler with optional equipment and deluxe jacket: 1 G-210-DWT boiler with (1) No. 232 tankless heater installed Nat. gas, 1000 Btu, .6 sg
For Other Optional Equipment, See page 15.
AT20D Transformer (except S.E.)
Drain valve Draft hood (for G-23-D and all flush jack
eted boilers shipped in separate carton)
Additional standard equipment
Water boilers ASME relief valve Pressure and temperature gauge L4080 (24V. and S.E.) Aquastat
limit control
Note:
Zone valve packages are available for water boilers. For details and prices, see page 34.
Steam boilers
ASME safety valve
Steam gauge
PA404A (24V. and S.E.) pressure limit control
No. 67-GAR (24V. and S.E.) low water cut-off
Gauge glass with trimmings Floor pan and radiation shield
Optional Equipment
Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit":
G-23 thru G-27 G-28 thru G-211
^ Trade Price $5.70 'wr Trade Price $7.70
yf See page 56
Page 7
HH-ll
BOILERS--GAS FIRED WATER AND STEAM
rSl AMERICAN ca STANDARD
HYDRONIC HEATING
G-40 GAS BOILERS
This fine boiler is ideal for installation in larger residences, small apartments, and commercial buildings. Has deluxe jacket with built-in draft hood. Note that tankless heaters
are available for both steam and water. Features "Ehmi naire" cast in the left end section.
Regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system. Self-energizing controls optional. Tested and equipped for 50 lbs. water working pressure with 80 lbs. water pressure optional at extra cost. Tested ratings shown are for installation at sea level and up to 2,000 ft.
WATER -- For Natural and Propane Oases -- 100% Shut-Off. For Built-In Water Heaters, see page 16.
boiler number
G-403-W G-404-W G-405-W G-4Q6-W G-407-W G-40B-W G-409-W G-4010-W G-4011-W G-4012-W G-4013-W G-4014-W
AGA input Mbh
150 2 25 300 375 450 525 800 675 750 825 900 975
A.G.A output
Mbh
120 180 240 300 360 420 480 540 600 660 720 780
net 1 =B=R
rating Mbh
104 3 156 5 208 7 260 9 313 0 365 8 417 4 469.6 521 8 574 0 626 2 678.4
net rating *q. ft water
695 1043 1391 1739 2006 2434 2782 3130 3479 3827 4175 4523
Trade Price with
standard equipment less thermostat
$ 404.00 513.00 622.00 737.00 652.00 939.00
1048.00 1158.00 1268.00 1380.00 1490.00 1598.00
approx. shipping weight
827 998 1162 1349 1517 1686 1856 2026 2195 2364 2533 2702
chimney size
inside diam. in
8 B 8 10 10 10 10 12 12 12 12 15
height feet
15 15 15 15 15 15 15 15 15 15 15 15
STEAM -- For Natural and Propane Gases -- 100% Shut-Off. For Built-In Water Heaters, see page 16.
boiler number
G-4Q3-S G-404-S G-40S-S G-406-S G-407-S G-4Q8-S G-409-S G-401Q-S G-4011-S G-4012-S G-4013-S G-4014-S
A.G.A. input Mbh
150 225 300 375 450 525 600 675 750625 900 975
A.G.A output Mbh
120 180 240 300 360 420 480 540 600 660 720 780
net 1 = B = R rating
Mbh
90 0 135 0 180.0 225 1 270.1 315.1 360.1 405.1 450.0 495.2 540.0 585.1
sq. ft.
375 563 750 936 1125 1313 1500 1688 1875 2063 2250 2438
Trade Price with
standard equipment less thermostat
$ 447.00 556.00 665.00 760.00 895.00 962.00
109100 1201.00 1311.00 1423.00 1533.00 1641.00
approx. shipping weight
858 1027 1195 1370 1544 1713 1880 2050 2219 2388 2557 2726
chimney site
inside diam. in.
8 8 8 10 10 10 10 12 12 12 12 IS
height feet
15 15 15 15 15 15 15 15 15 15 15 15
Ordering Examples:
1. Water boiler with standard equipment: 1 G-406-W boiler Nat. gas, 1000 Btu, .6 sg.
2. Steam boiler with optional equipment: 1 G-409-ST 1 No. 226 tankless heater with controls Nat. gas, 1000 Btu, .6 sg.
Standard equipment
V-8139A Combination Gas Valve: G-403 and G-404 for Natural Gas V-8139B Combination Gas Valve: G-403 thru G-407 for Propane Gas G-50AAG Combination Gas Valve: G405 and G-406 for Natural Gas V-88A Diaphragm Gas Valve: G-407 thru G-4014 for Natural Gas
G-408 thru G-4014 for Propane Gas Gas pressure regulator (except propane gas) Manual main gas shut-off valve Manual pilot gas shut-off valve where diaphragm gas valve is standard. AT30 Transformer (except S.E.)
L62GB (24V.) or CS591A (S.E.) combination pilot switch and valve with auxiliary pilot valves (100% shut-off)
Drain valve Water heater opening cover plates
Additional standard equipment
Water
ASME relief valve Pressure and temperature gauge L4006A (24V. and S.E.) immersion limit control
Zone valve packages are available for water boilers. For details and prices, see page 34.
Steam
ASME safety valve Steam gauge PA404A (24V. and S.E.) pressure limit control Gauge glass with trimmings No. 67-GAR (24V. and S.E.) low
water cut-off
Optional equipment (See pages 15, 16 and 17)
HH-11 See page 56
Page 8
02408
_ AMERICAN S STANDARD
HYDRONIC HEATING
PACKAGED BOILER GAS FIRED WATER
GWP PACKAGED GAS BOILER
(Single Boiler Installation)
The GWP boiler package offers a ready-to-install heating plant for large residences, small apartment and commercial buildings. Designed for forced circulation only, the GWP includes factory mounted and wired controls. Burners are installed and deluxe jacket is factory mounted. Relief valve, temperature-pressure gauge and draft hood are shipped separately. The patented "Eliminaire" is also included.
Boiler is tested and equipped for 50 lbs. working pressure and regularly furnished foi 115 volt, 60 cycle power supply with 24 volt control system. Self-energizing controls arc available at no additional cost.
Ratings shown are for installations at sea level and up to 2000 ft.
WATER--100% shut-off--Natural and Propane Gas
packaged boiler
number*
GWP-5
GWP-6
GWP-7
A.C.A. input Mbh
264
330
396 _
A.G.A. output
Mbh
211.2
264,0
316.8
not 1 = 8=8
Mbh
183.5
229.6
275.7
chimney tut
Intide die. >n.
7
height feet
15
8 15
8 15
appro* ihippmg weight
613
716
823
Trod* frtcc with
standard equipment lets Ihermettat
$ 430.00
520.00
620.00
Standard equipment
Combination automatic gas valve
Gas pressure regulator (except propane)
Manual main gas shut-off valve Manual pilot gas shut-off valve AT-20D transformer (except S.E.) Pilot Valve & Switch Drain Valve ASME Relief Valve
Pressure-Temperature Gauge
Deluxe Jacket
L4080D Immersion Limit Control
Draft Hood
Drilled Port Burners are standard for natural gas.
Ribbon Burners are standard for propane gas and optional for nat ural gas.
Optional equipment
Self Energizing controls
No Price Add
Zone Valve Packages are available (for details and prices see page 34)
Add suffix "R" to model number if ribbon burners are desired.
Example: GWP-5R
Optional constant circulation (24 volt) L4081B limit and reverse acting circulator controls instead of L4080 limit control. Added Trade Price $10.30
See page 56
Page 9
HH-11
MODULAR GAS FIRED WATER BOILER
^AMERICAN Si STANDARD
HYDRONIC HEATING
GWM GAS MODULAR BOILER HOOK-UP
(Modular Boiler Installations)
The GWM Modular Boiler Hook-up is a combination or multiple of five, six or seven section GWM boiler modules. Each module has factory assembled sections with burners, gas manifold, and automatic gas valve mounted. Deluxe jacket, controls and draft hood are shipped separately. The patented "Eliminaire" is a standard feature.
Factory fabricated water manifolds are available as listed under optional equipment.
GWM Modular Boilers are furnished for 115 volt, 60 cycle power supply with 24 volt control system. (Self-energizing controls are not available). Boilers are tested and equipped for 50 PSIG working pressure. Indicated ratings are for installation at sea level and up to 2000 ft. elevation.
GWM BOILER MODULES -- Natural and Propane Gas: 100% Shut-Off.
module boiler number*
GWM-5
GWM-6
GWM-7
AG.A input Mbh 264
330
396
A.G.A output Mbh 211.2
264.0
316.8
net l=ft = R
rating Mbh
183.5
229.6
275.7
opprox. shipping woightt
lbs.
629
735
846
Trod* Price with
standard equipment less thermostat
$418.00
508.00
608.00
Standard equipment
Combination automatic Gas Valve
Gas pressure regulator (except propane)
Manual Main Gas shut-off valve
Manual pilot gas shut-off valve
Transformer Belay Pilot valve and switch Drain Valve ASME Relief Valve(s) as required
Pressure-Temperature Gauge as required
Deluxe Jacket
L4080D Immersion Limit Control
Draft Hood
Drilled Port Burners are standard for natural gas.
Ribbon burners are standard for propane gas and optional for nat ural gas.
Optional equipment
1. Factory fabricated Water Manifold for Primary/Secondary circulation. Includes interconnecting supply piping (Boiler to manifold). Inter connecting return piping and circulator not included. Trade Price add per module $41.00
2. Factory fabricated Water Manifold for Parallel Boiler Hook-up. In cludes interconnecting supply and return piping (boiler to manifold). ................................................................Trade Price add per module $82.00
3. Electronic Control Panel Systems-- For application and details, contact American-Standard.
Add suffix "R" to model number if ribbon burners are desired.
HH-11 See page 56
Page 10
a 02410
(AMERICAN ei STANDARD
HYDRONIC HEATING
MODULAR GAS FIRED WATER BOILER
GWM GAS MODULAR BOILER HOOK-UP
(Modular Boiler Installations)
The following boiler units in 66,000 BTU input increments are achieved with module boiler combinations:
MODULAR BOILER HOOK-UPS -- Natural and Propane Gas - 100% Shut-Off.
unit number
GWM-528 GWM-594 GWM-660
GWM-726 GWM-792 GWM-858
GWM-924 GWM-990 GWM-1056
GWM-1122 GWM-1188 GWM-1254
GWM-1320 GWM-1386 GWM-1452
GWM-1518 GWM-1584 GWM-1650
GWM-1716 GWM-1782 GWM-1848
GWM-1914 GWM-1980 GWM-2046
GWM-2112 GWM-2178 GWM-2244
GWM-2310 GWM-2376 GWM-2442
GWM-2508 GWM-2574 GWM-2640
GWM-2706 GWM-2772 GWM-2838
GWM-2904 GWM-2970 GWM-3036
GWM-3102 GWM-3168 and upward
modular competition 5 ictl. 4 ioct. 7 tact.
2 1 1_
2-
__ 1
__
1 2
2 1-
2 __ 3_ -2
12
__
3
3-
4 __
_3 -22
_i3
__ __
4
- 5-
4 __ 3 -2
_ __
-5
2 3
4 5 1
_
4 3
2 3
-24
5 __ 6
52
_
4 3
-2
_
__ _
-5
3 4
s
6 7 3
_4 _3 -2
__
~"
4 5 6
7 8
grot* input Mbh
528 594 660
726 792 858
924 990 1056
1122 1188 1254
1320 1386 1452
1518 1584 1650
1716 1782 1848
1914 1980 2046
2112 2178 2244
2310 2376 2442
2508 2574 2640
2706 2772 2838
2904 2970 3036
3102 3168
grots output Mbh
422.4 475.2 526.0
580.8 633 6 686.4
739.2 792.0 844.8
897.6 950.4 1003.2
1056.0 1108.8 1161.6
1214.4 1267.2 1320.0
1372.B 1425.6 1478.4
1531.2 1584.0 1636.0
1689.6 1742.4 1795.2
1848.0 1900.8 1953.6
2006.4 2059.2 2112.0
2164.8 2217.6 2270.4
2323.2 2376.0 2428.8
2481.6 2534.4
not output Mbh
367.0 413.9 459.1
504.3 551.3 596.5
643.5 688.7 733.9
780.9 826.1 873.0
918.3 963.5 1010.4
1055.7 1102.6 1147.8
1193.0 1240.0 1285.2
1332.2 1376.4 1422.6
1467.8 1516.5 1561.7
1607.0 1652.2 1697.4
1746.1 1791.3 1836.5
1881.7 1927.0 1975.7
2020.9 2066.1 2111.3
2156.5 2205.2
approx shipping weight
1258 1364 1470
1581 1692 1993
2099 2205 2316
2427 2538 2834
2940 3051 3162
3273 3384 3675
3786 3897 4008
4119 4230 4521
4632 4743 4854
4965 5076 5367
5478 5589 5700
5811 5922 6213
6324 6435 6546
6657 6768
Modular Operating Control Package Options
1. Four stage immersion type operating control, (one required for up to 4 modules) ...................................... Trade price add per control $70.00
2. Immersion type operating controls with individual outdoor resets. Trade price add per module $47.00
3. Eight stage boiler sequencing control package with outdoor reset, (one
required for up to 8 modules)
Trade price add per control $270.00
Trade Price with standard equipment
S 820.00 910.00
1000.00
1100.00 1200.00 1312.00
1402.00 1492.00 1592.00
1692.00 1792.00 1894.00
1984.00 2084.00 2184.00
2284.00 2384.00 2492.00
2592.00 2692.00 2792.00
2892.00 2992.00 3084.00
3184.00 3284.00 3384.00
3484.00 3584.00 3676.00
3776.00 3876.00 3976.00
4076.00 4176.00 4266.00
4368.00 4468.00 4568.00
4668.00 4768.00
'W See page 56
Page 11
HH-11
02411
non-packaged
gas fired
WATER
AMERICAN baSTANDARD
HYDRONIC HEATING
GW NON-PACKAGED GAS WATER
(Single or Modular Boiler Installations)
The GW Boiler is a non-packaged boiler available in three sizes designed for forced circulation only. Factory assembled sections are standard with jackets, burners and manifolds shipped separately. Included for field installation are a relief valve, tempera ture-pressure gauge, and draft hood. The patented "Eliminaire" is also included.
Installed individually or in modular groups, the GW boiler is ideal for renovation work as well as new construction.
Each boiler is tested and equipped for 50 PSIG working pressure and regularly fur nished for 115 volt, 60 cycle power supply with 24 volt controls. Self-energizing controls are available at no additional cost.
Ratings shown are for installations at sea level and up to 2000 ft. elevation.
INDIVIDUAL BOILERS -- WATER -- 100% shut-off -- Natural and Propane Gas
chimney tile
boilei niwnber*
A G A. input Mbh
A.G.A. output
Mbh
not l =6 = R
Mbh
Inside dio in.
height 4eet
GW-8
GW-9 GW-10
462 528 594
369.4 422.4 475.2
321.7 367.0 413.9
9 10 10
15 15 15
approx shipping
weight
938 1052 1177
Trade Price with
standard equipment lest thermestot
$ 670.00 725.00 780.00
MODULAR BOILERS -- WATER - 100% shut-off -- Natural and Propane Gas
unit numbe*
GW-924 GW-990 GW-10S6
GW-1122 GW-1188 GW-1386
GW-14S2 GW-1518 GW-1584
GW-1650 GW-1716 GW-1782
GW-1848 GW-1914 GW-1980
GW-2046
modular composition
ted
9 ted
10 sect.
200 1 10 --0 2 0
01
1
00 2
300
210 1 20 030
02 1
01
2
003
400 310 220
1 30
III
924
990
1056
1122 1188 1386
1452 1518 1584
1650 1716 1782
1848
1914
1980
2046
gross output
Mbh
739 792 845
879 950 1108
1162 1214 1267
1320 1373 1426
1478 1531 1584
1637
net output
Mbh
644 689 734
781 826 964
1010 1056 1103
1148 1193 1240
1285 1332 1376
1423
approx thrppmg weights
1876 1990 2104
2229 2354 2814
2928 3042 3156
3281 3406 3531
3752 3866 3980
4094
Trade Price with standard equipment
less thermoitot
$ 1340.00 1395.00 1450.00
1505.00 1560.00 2010.00
2065.00 2120.00 2175.00
2230.00 2285.00 2340.00
2680.00 2735.00 2790.00
2845.00
Standard equipment
Combination automatic gas valve Gas pressure regulator
(except propane)
Manual gas shut-off valve Manual pilot gas shut-off valve AT-20D Transformer (except SE)
Pilot Valve and Switch Drain Valve ASME Relief Valve
Pressure-Temperature Gauge
L-4080D Immersion Limit Control
Deluxe Jacket
Draft Hood
Drilled Port Burners are standard for natural gas.
Ribbon Burners are standard for propane gas and optional at no price add for natural gas.
Optional equipment
Self-energizing controls .................................
.......... no price add
Electronic Control Panel System -- For application and details, contact American-Standard.
Modular Operating Control Package Options
1. Four stage immersion type operating control (one required for up to 4 modules) ..................................... Trade Price add per control $70.00
2. Immersion type operating controls with individual outdoor resets (one required for each module)..............Trade Price add per module $47.00
3. Eight stage boiler sequencing control package with outdoor reset (one required for up to 8 modules) . Trade Price add per control $270.00
Add suffix "R" to model number if ribbon burners are desired.
HH-11 See page 56
Page 12
02412
AMERICAN cd STANDARD
HYDRONIC HEATING
BOILERS-GAS FIRED WATER
G-10 GAS BOILERS
A compact, high capacity boiler for commercial and industrial application. Features single com bustion chamber to simplify wiring and controls. Built-in heaters available for storage tank or tankless application. Tested and equipped for 60 lbs. water working pressure with 80 lbs. water working pressure optional at extra cost.
Integral draft hood located at rear of boiler with optional top outlet (except G-1010) available at no extra charge.
WATER -- Natural Gas -- 100% Shut-Off. For Built-In Water Heaters, see page 16.
boiler number
A.G.A. input
Mbh
A.G.A. output
Mbh
* net l = B = R rating Mbh
1=B=R
piping and
pick-up factor a
rTrade Price
net rating sq. ft. water
with standard equipment
less
thermostat
approx
shipping weight
chimney size
inside diam. in.
ht. ft
G-105-W G-106-W G-107-W
G-10B-W G-109-W G-1010-W
G-1011-W G-1012-W G-1013-W
G-1014-W G-1015-W G-1016-W
G-1017-W G-1018-W G-1019-W
G-1020-W G-1021-W G-1022-W
G-1023-W G-1024-W G-1025-W
G-1026-W G-1027-W G-1028-W
G-1029-W G-1030-W G-1031-W
G-1032-W G-1033-W
800 1000 1200
1400 1600 1800
2000 2200 2400
2600 2800 3000
3200 3400 3600
3800 4000 4200
4400 4600 4800
5000 5200 5400
5600 5800 6000
6200 6400
640 800 960
1120 1280 1440
1600 1760 1920
2080 2240 2400
2560 2720 2880
3040 3200 3360
3520 3680 3840
4000 4160 4320
4480 4640 4800
4960 5120
556 5 695.7 834.8
973.9 1113.0 1252.2
1391.3 1530.4 1669.6
1808.7 1947.8 2087.0
2226.1 2365.2 2504.3
2643.5 2782.6 2921.7
3060.9 3200.0 3339.1
3478.3 3617.4 3756.5
3895.7 4034.8 4173.9
4313.0 4452.2
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15
3710 4638 5565
6493 7420 8348
9275 10203 11131
12058 12985 13913
14841 15768 16695
17623 18551 19478
20406 21333 22261
23189 24116 25043
25971 26899 27826
28753 29080
$1260.00 1535.00 1807.00
2097.00 2343.00 2593.00
2856.00 3188.00 3561.00
3870.00 4112.00 4366.00
4632.00 4909.00 5198.00
5441.00 5729.00 5983.00
6272.00 6537.00 6780.00
7069.00 7346.00 7543.00
7739.00 8039.00 8282.00
8524.00 8776.00
2905 3443 3990
4536 5093 5657
6231 6646 7159
7679 8252 8746
9244 9753 10265
10801 11278 11841
12351 12860 13391
13864 14376 14674
15378 15868 16391
16896 17405
14 14 14
16 16 18
18 20 20
22 22 22
22 24 24
24 26 26
26 26 28
28 28 28
30 30 30
30 30
20 20 20
20 20 20
20 20 20
20 20 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30
* The net l = B = R ratings shown are based on the factors shown in the piping and pickup column American Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements.
Standard equipment
V88A gas valve(s)
Drain valve
Gas pressure regulator (except
Draft hood
Propane gas)
L62GB combination pilot switch and
Manual main gas shut-off valve
valve 817F-11 pilot valves
Manual pilot gas shut-off valve
Pressure and temperature gauge
AT20D Transformer
L4006A immersion limit control
Ribbon type main burners
Optional equipment: See pages 15,16 and 17
ASME relief valve
Ordering Examples:
1. Water boiiar. 1 G1013-W boiler Nat gas, 1000 Btu.
6 sg
"W See page 56
G-10 GAS BOILERS -- WATER for Propane Gas
Propane Gas Ratings are determined by reducing the Natural ratings above by 10%. Example: G-105-W A.G.A. input 800 less 10%=720 Mbh Input for Propane Gas. Detailed Propane Gas ratings are shown in current Technical Literature Trade Prices. Chimney Sizes and shipping weights remain the same as shown above
Page 13
HH-11
02413
BOILERS-GAS FIRED STEAM
^AMERICAN ksiSTANDARD
HTDRONIC HEATING
G 10 GAS BOILERS --
This steam boiler is ideal for new work or modernization. Features a deluxe jacket which may be assembled to the boiler after piping has been installed. Integral draft hood locat ed at rear of boiler with optional top outlet (except G1010) available at no extra charge.
This boiler is regularly furnished for 116 volt, 60 cycle power supply with 24 volt con trol system. Ratings shown are for installation at sea level and uo to 2.000 ft.
STEAM -- For Natural Gas -- 100% Shut-Off. For Built-In Water Heaters (G-105S thru G 1014S only) See page 16.
number
A.G.A. input
Mbh
A.G.A. output
Mbh
a net J=B - R rating
Mbh
sq. ft.
|r=0 = R
piping and pick-up factor a
''Trade Price with standard equipment less thermostat
approi shipping
weight
chimney size
inside dtam. in.
ht. ft.
G-105-S G-106-S G-107-S
G-108-S G-109-S G-IOtO-S
G-1011-S G-1012-S G-1013-S
G-1014-S G-1015-S G-1016-S
G-1C17-S G-1018-S G-1019-S
G-1020-S G-1021-S G-1022-S
G-1023-S G-1024-S G-1025-S
G-1026-S G-1027-S G-102S-S
G-1029-S G-1030-S G-1031-S
G-1032-S G-1033-S
800 1000 1200
640 800 960
1400 1600 1800
1120 1280 1440
2000
2200
2400
1600 1760 1920
2600 2800 3000
2080 2240 2400
3200 3400 3600
2560 2720 2880
3800 4000 4200
- 3040 3200 3360
4400 4600 4800
3520 3680 3840
5000 5200 5400
4000 4160 4320
5600 5800 6000
4480 4640 4800
6200 6400
4960 5120
480.1 600.1 720.2
840.2 962.4 1095.1
1227.9 1361.2 1489.5
1614.9 1739.1 1863.4
1987.6 2111.8 2236.0
2360.2 2484.5 2608.7
2732.9 2857.1 2981.4
3105.6 3229.8 3354.0
3478.3 3602.5 3726.7
3850.9 3975.2
2000 2501 3001
3501 4010 4563
5116 5672 6206
6729 7246 7764
8282 8799 9317
9834 10352 10870
11387 11905 12422
12940 13458 13975
14493 15010 15528
16046 16563
1.333 1.333 1.333
1.333 1.330 1.315
1.303 1.293 1.289
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288
$1304.00 1579.00 1851.00
2141.00 2387.00 2637.00
2900.00 3232.00 3625.00
3914.00 4156.00 4410.00
4676.00 4953.00 5242.00
5485.00 5773.00 6027.00
6316.00 6581.00 6824.00
7113.00 7390.00 7587.00
7783.00 8083.00 8326.00
8568.00 6822.00
2910 3453 4000
4548 5103 5667
6241 6646 7159
7679 8252 8748
9244 9753 10265
10801 11278 11841
12351 12860 13391
13884 14376 14874
15378 15868 16391
16898 17405
14 14 14
16 16 18
18 20 20
22 22 22
22 24 24
24 26 26
26 26 28
28 28 28
30 30 30
30 30
20 20 20
20 20 20
20 20 20
20 20 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30
a The net l=B=R rating* shown are based on the factors shown in the piping and pickup column American Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements.
Standard equipment
Ij '[ !l HH-11
See page 56
V88A gas valve(s) Gas pressure regulator
(except propane gas)
Manual main gas shut-off valve Manual pilot gas shut-off valve AT30 Transformer ASME safety valve Steam gauge Ribbon type main burners
Ordering Examples:
Steam boiler with standard equipment 1 G1015-S boiler Nat (as, 1000 8tu, .65 sg
Drain valve Draft hood 853-1 combination pilot switch and
valve 817F-11 pilot valves PA404A pressure limit control Gauge glass with trimmings No 67AR Low Water cut-off
Optional equipment
(See pages 15,16 and 17)
G-10 GAS BOILERS -- STEAM for Propane Gas
Propane Gas Ratings are determined by reducing the Natural Gas ratings above by 10%. Example G-105-S A.G.A. Input 800 less 10%=720 Mbh Input for Propane Gas. Detailed Propane Gas ratings are shown in current G-10 Technical Literature. Trade'Prices. Chimney Sizes and shipping weights remain the same as shown above.
Page 14
< <
02414
^AMERICAN izi STANDARD
HYDRONIC HEATING
MISCELLANEOUS OPTIONS GAS BOILERS
MISCELLANEOUS OPTIONS - NON-PACKAGED GAS BOILERS
G-2, G-40 AND G-10 BOILERS: Thermostats are available at Trade Prices shown on page 35.
Side Outlet ASME Steam Safety Valve may be substituted at no additional charge if specified on order to meet local code requirements.
"IS" Equipment: boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. L4006A immer sion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on page 35. This control operates gas valves on boiler electrically as required. Shipping weights of gas boilers for hot water supply are same as shown for regular
gas boilers.
Low water cut-offs for water boilers: No. 63 cut-off for water
working pressures of 50 lbs., or less, available when speci
fied at additional Trade Price of
(42.75
No. 150 cut-off for water working pressures in excess of 50
lbs. available when specified at additional Trade Price of $64.25
G-2 BOILERS:
"DW" (Direct Water) equipment: In addition to water boiler standard equipment, page 7, includes pressure gauge, 80 lb. ASME relief valve, L4006A Aquastat for storage tank, tank thermometer, name and rating plate for 80 lbs. water work ing pressure. Specify boiler with "DW" equipment and add $16.50to Trade Price of All-Purpose Water Boiler, page 7.
Floor shield for combustible flooring. Add suffix letter "CM to
boiler number and add to Trade Price of boiler
$3.28
G-2 ANO G-40 80ILERS:
Self-energizing control: All size G-2 and G-40 for propane gas. All G-2 and G-40 thru G-4010 for natural gas. Equip ment includes: S.E. gas valve as required, Q313A Thermo pile Generator and a L4006 S.E. limit control (water boilers less heater) or an L8124B Triple Aquastat Relay (water boilers with heater) or a PA404A Pressuretrol (steam boilers less heater). For steam boilers with heater L4006A S.E. immersion operating control will be furnished in addi tion to the Pressuretrol. Furnished at no additional charge when specified on order. Special thermostat required, for Trade Price, see page 35.
No. 101-24V electric water feeder can be added to the No.
67-GAR low water cut-off regularly furnished with
steam boilers to provide low water cut-off and feeder combi
nation at additional Trade Price of
$55.81
Zone circulator control for water boiler with tankless heater and combination immersion control-relay: use one T822D thermostat and one R845A relay for second and/or third
zone. For Trade Prices, see page 35.
Water flow regulators sized for tankless heater involved will
be furnished with heater when specified on order to meet
local Utility requirement at Trade Price additional charge
per heater of
$3.25
G-40 AND G-10 BOILERS:
No. 47-2 boiler water feeder and cut-off combination is avail able instead of the 67-AR regularly furnished with G-403 through G-108 steam boilers at additional Trade Price of
....................................................................................... $41.60
No. 51-2 boiler water feeder and cut-off available instead of
No. 67-AR regularly furnished with G-109 thru G-1031
steam boilers at additional Trade Price of
$62.70
Try-cocks and tappings: if desired for steam boiler to meet
local code specify on order and add to Trade Price of steam
boiler
.
$4.25
Boilers tested for 80 lbs. water working pressure: available
when specified on order. Add per section to Trade Price of
water boiler
$8.00 per section
G-40 BOILERS:
Boilers with Tankless Heaters: water (for forced circulation) and steam boilers can be furnished with tankless heaters. Heaters are limited to boiler sizes as shown in ratings table on next page. Specify heater and add suffix "T" to boiler number.
Factory assembled sections: G-403 through G-4014 can be shipped with sections factory assembled when specified on order. Add $11.00 per section to Trade Price of boiler.
G-10 BOILERS:
Pilot filters for G-10 for natural and mixed gases available at no additional charge when specified on order to meet local utility codes.
G-10 Steam Boiler external water heater tappings in cover
plates: maximum size
Specify number of cover plates
with tapping. Added Trade Price per tapping
$4.25
G-10 Right End Section Steam Trim Tappings for pressure gauge and water column fittings or for auxiliary controls furnished as standard equipment at no additional charge.
Modulating gas valve: the G-10 boiler can be specified with the V6034A/V5034A gas valve for Hi-Lo-off operation. This valve permits adjustment of the Lo-fire operation down to a minimum of 20% of the boiler input. Operation of the valve should be controlled by a SPDT operating control. If
desired, specify on order and add to the Trade Price of the boiler with regular equipment the following Trade Prices.
G-105 thru 1018................................................................$161.50
G-1019 thru 1033 .
$205.00
Top outlet drafthood (natural gas only); available (ex cept G1010) at no extra charge when specified on order. See current literature for chimney recommendations.
Factory assembled sections: Available thru G-1011. Specify
on order. Allow 3 week lead time. Added Trade Price per
section
$21.00
'W See page 56
Page 15
HH-11
02415
AMERICAN calSTANDARD
HYDRONIC HEATING
tankless heaters-gas fired WATER AND STEAM
G-2 TANKLESS HEATERS
G 2 NONPACKAGED ALL-PURPOSE BOILER:
Factory installed tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation. See table below for I=W = H ratings and applicable boiler size. Specify heater, add suffix "T" to boiler number and "factory installed." Add Trade Price shown.
Ratings
boiler number
A.G.A. Input Btu/hr.
heater 218
| = W=sH Rating
heater 222
heater 226
G-24
90.000
2`/z
--
--
G-25
120.000
--3
--
G-26
150,000
-- 3 Vi
--
G-27
180,000
--
3>/2 4
G-28
210,000
--
3% 4'/i
G-29
240,000
-- 3V2 4 Vi
G-210
270.000
--
3V2 4 Vi
G-211
300,000
-- 3>/2 4 y2
G-2 PACKAGED AND NON-PACKAGEDALL-PURPOSE BOILERS:
Tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation I = W = H tankless heaters can be installed in opening used for gravity tapping flange cover. See table for I=W = H ratings and applicable boiler size Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below.
Trade Prices
heater 232
--
----
heater number
218 222 226 232
factory Installed
$45.00 49.00 61.00 69.00
sold separate
$24.00 28.00 40.00 48.00
--
-- * L8124E for 24 Volt or L8124B for SE. Triple Aquastat Relay furnished with
4`/2 heater (packed in trim box).
4 V* Water flow regulator. Specify on order. Added
5 Trade Price
$3.25
G-40 TANKLESS HEATERS -- STEAM OR FORCED WATER BOILERS
Ratings (Gallons per minute*)
Trade Prices
Boiler
HEATER 218 HEATER 222 HEATER 226 HEATER 232 HEATER 445 HEATER 460 Steam Water Steam Water Steam Water Steam Water Steam Water Steam Water
G-403
3
G-404
3 V;
4 4 V;
G-405
3 Vi
4 4 V; 5'/j 6
----
---
--
G-40* G-407
3 Vi .,3%
4 4 V? 5 Vi 6
---- ----
4 i'A
6 evi
7 7 V; -- --
-- --
G-408 G-409
3% 3% 4
4 4 Vi 6 6>/i 7Vi 8 BVi 4 4 '/i 6 6 Vi m 8 ZVi 9
-- --
G-4010 G4011 G-4012
3W 3%
m
4 4 4
4 4'/} 4 4'/* 4 4'/,
6 6Vr 7 % 8 m
6 6 V;
8
6 6 Vi 7Vi 8 8%
-- 11 12
G 4013 3Vi
4
4 4 V;
6 6 Vi 7Vi B 8 Vi
13
G-4014
3 Vi
4
4 4 Vi
6 6 Vi 7% 8 8'A
13
Gallons of water per minute aised from 40*F lo 140*F with 200'F boiler water temperature.
-- -- -- -- -- 12 13 14 Vj 15'A
G-10 BOILERS --TANKLESS OR TANK TYPE HEATER
No. 1023 heater is available in any quantity. Specify number
required. Trade Price each
$33.50
HEATER NO.
HEATER WITH CONTROLS
Water
Steam(')
HEATER ONLY Water or Steam
218
344.00 338.00
324.00
222
46.00
42.00
28.00
226
58.00
54.00
40.00
232
66.00
62.00
48.00
445
79.00
75.00
61.00
460
85.00
81.00
67.00
Tankless heaters with controls for water boilers: L8124E combination immersion control-relay packed in trim box in place of standard limit control.
Tankless heaters with controls for steam boilers: L4006A immersion operating control
packed in trim box in addition to PA404A pressure limit control.
Water flow regulator. Specify on order. Added
Trade Price
$3.25
(') Additional L4006A operating control re
quired for steam boiler-heater combina
tions shown shaded. Add to above heater
w/control Trade Price
$14.05
The ratings table on this page shows the ratings attained if more than one heater is connected in parallel.
Copper pipe manifolds, factory assembled for multiple heater parallel hookup, shipped in boxes of 2 manifold assemblies per box, when specified with heaters, are avail able at the following charges:
Manifold Assembly Two Heater i Three Heater Four Heater
Trade Price
S 7.25
11.00
14.00
All G-10 water boilers and sizes G-106S thru G-1014S steam
boilers can be provided with sections for insertion of heaters
at no extra charge. When desired add suffix letter T to boiler
number and specify the number of sections with heater
openings. Cover plates to close unused water heater openings
will be furnished only if specified on order at Trade Price
each
$4.50
When specified, the G-10 water boiler with heater can be provided with the combination L8124E in place of the L4006A limit control at the added Trade Price of $18.50
When No. 1023 heaters are used in steam boilers, the L4006A operating control will be required for installation in a heater tapping. See page 35 for Trade Price.
When the No. 1023 heaters are used in a storage type domestic hot water system, the L4006A operating control will be required for insertion in a storage tank, see page 35" for the Trade Price.
NO. 1023 HEATER RATINGS TANKLESS APPLICATION
boiler number
no. of tankless
beaters
Intermittent draw
heater rating gpm @ 100 rrse
pressure drop (with manifolds)
PSI
G-105 - G-1033 G-105 - G-1033
G-106 G-1033
G-108 G-1033
2
3 4
4 3/a
7 Vi 10 1 2 3/a
NOTE: Heaters for Stasm Boilers available 5 thru 14 sections only
19
STORAGE TANK APPLICATION
boiler number
number
of haaters
continuous draw
100 rise
(pm
recovery capacity 100 rise
fph
boiler
output required
mbh
G-105 - G-1033 G-105 - G-1033 G-106 - G-1033 G-108 - G-1033
G-1011 -G-1033 G-1023 - G-1033 G-1014 -G-1033 G-1016 G-1033
G-1018 - G-1033 G-1020 - G-1033 G-1022 - G-1033 G-1024 G-1033
1 2 3 4
5 6 7 8
9 10 11 12
4 240 200 7 420 350 10 600 500 13 780 650
16 960 800
19 1.140 950
22
1.320
1,100
25
1.500
1.250
28
1.680
1.400
31
1.860
1,550
34
2.060
1.700
37
2.220
1,850
NOTE: Heaters for Steam Boilers available 5 thru 14 sections only
storage tank size (als.
500 500 500 1.000
1,000 1.000 1.500 1.500
1.500 2.000 2.000 2.000
HH-11 'W See page 56
Page 16
02416
AMERICAN iZiSTANDARD
HYDRONIC HEATING
f.m./f.i.a. special gas controls ELECTRONIC CONTROLS
G-40 AND G-10 CONTROL OPTIONS
G-40 AND G-10 BOILERS:
F M or F.I.A equipment f I A requires special gas train PLUS F.I.A. electronic panel
Special gas manifold control equipment that meets F.M. or F.I.A iniumiiLJN requirements are available at the Trade Price listed For actual F.I A. installations and before boiler installation, signed approval by F.I.A. inspector of both electronic control? and gas manifold control equipment being used should be obtained. Submittal data for F.M. or F.I.A. equipment is available from American-Standard. Electronic control systems are available as described and at the Trade Prices listed below
Note: A low water cut-off for water boilers (50 lb. or 80 lb water working pressure) will be furnished as required and charged for at the prices shown for .No. G3 or No. 150 on page 15
F.M. & F.I.A. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY)
ADD TO BOILER TRADE PRICE "W
BOILER NUMBER
F M ()
F 1 A.(:)
G-403 thru G-4014 G-105 thru G-106 G-107 G-108 thru G-1011 G-1012 thru G-1017 G-1018 G-1019 thru G-1030 G-1031 thru G-1033
$ 84.00 73.00 85.00 75.00
122.00
164.00 170.00 218.00
$437.00 439.00 473.00 572.00 651.00 710.00 757.00 879.00
Ul F M gas control equipment includes two manual shut-oH valves, a test vent valve and one HO valve
l;) F i a gas control equipment includes two manual snut-oft valves, Hi and LO pressure switches, two HO waives and a vent valve.
G-40 AND G-10 ELECTRONIC CONTROL PANEL SYSTEMS
(FOR 115 VOLT, 60 CYCLE 1 PHASE POWER ONLY)
Panel System EPG-M: Provides manual ignition. 100r;
safety shut-off with electronic^ supervision of pilots 1 to 3.
Main burners and pilots are turned off on pilot failure. Continuous flame pilot operation. Equipment includes: one
panel for each electronic pilot (Mam panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Baso
valves and thermocouples and Q-179B electronic flame rod and pilot; RA890F protectorelay installed on panel; 3 ft.
flame rod wire per pilot. Panel System EPG-ES: Provides electronic supervision of
each pilot (1 to 3} and interrupted continuous burning pilot electronically turned off and electrically relighted on
every cycle to achieve positive component check of relays and pilot system. Complete automatic operation of boiler. 100rr safety shut-off. Equipment includes: one panel for
each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panels with 2-4 seconds response timing and alarm con
tacts; minimum of 3 ft. of flame rod wire and 3 ft. of
ignition cable per pilot.
Panel System EPG-E: Provides electronic supervision of each pilot (1 to 3) and intermittent electric ignition of all
pilots. Complete automatic operation of boiler. lOO'T safety shut-off. Equipment includes: one panel for each electronic
pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric
ignition pilots; ignition transformer; Y-1040C pilot solenoid valves; RA890F protectorelay installed in panel with 2-4 seconds response timing and alarm contacts: minimum of
3 ft. of fiame rod wire and 3 ft. of ignition cable per pilot.
Panel System EPG-M(FIA): Specifically designed to meet FI A requirements. Provides constant burning manually lighted electronically supervised pilots (1 to 3i. 100rr safety shut-off. Equipment includes: one pane) for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled: alarm bell, alarm silencing switch; purge timer, all factory assembled in master panel; RA 890F protectorelay installed in panel: Baso valves and thermocouples and Q-179B electronic flame rod pilot; 3 ft. flame rod wire per pilot.
ADDITIONAL CHARGES-^Trade Price
Specify on order type of system desired, as described above, and add charge for boiler size involved to Trade Price of boiler with regular equipment.
PANEL SYSTEMS EPG-M
boiler no.
system no.
G-403 thru G-4014
EPG-M1
G-105 thru G-1012
EPG-M1
G-1013 thru G-1023
EPG-M2
G-1024 thru G-1033
EPG-M3
added chare* (1)
$206.00 206.00 396.00 594.00
PANEL SYSTEMS EPG-E
boiler no.
system no
G-403 thru G-1014
EPG-E1
G-105 thru G-1012
EPG-E1
G-1013 thru G-1023
EPG-E2
G-1024 thru G-1033
EPG-E3
added charge (1)
$228.00 228.00 420.00 630.00
PANEL SYSTEMS EPG-ES
boiler no
system no
added charge (1}
G-403 thru G-4014
EPG-ES1
$272.00
G-105 thru G-1012
EPG-ES1
272.00
G-1013 thru G-1023
EPG-ES2
464.00
G-1024 thru G-1033
EPG-ES3
675.00
PANEL SYSTEMS EPG-M(FIA)
boiler no
system no.
added charge
G-403 thru G-4014
EPG-MI(FIA)
$376.00
G-105 thru G-1012
EPG-MI(FIA)
376.00
G-1013 thru G-1023
EPG-M2(FIA)
575.00
G-1024 thru G-1033
EPG-M3(FIA)
782.00
Flame Rod Wire: Trade Price per foot Ignition Cable: Trade Price per foot
$0.40 0.85
`Trace once* apply to equipment when shipped v. ith hotler For field convers ons, price on application
Note if purge timer is desired specify on orae' and add $62.0QTrade Price
See page 56
Page 17
HH-ii
02417
packaged
BOILER-BURNER UNITS
WATER
AMERICAN kS STANDARD
HYDRONIC HEATING
AP(T) PACKAGED BOILER-BURNER UNITS
Designed and equipped with controls for forced circulation.
Here's a competitively priced oil-fired cast iron boiler-burner unit just loaded with features that sell. Available with or without I-W-H rated tankless heater, this pack aged winner features the incomparable DH Burner and has the patented "Eliminaire" (cast-in air separator) that is exclusive with American-Standard
Factory assembled, pre-wired and crated, this quality cast iron boiler at a budget price, is tested and equipped for 30 lbs. water working pressure.
Motor and controls are regularly furnished for 115 volt, 60 cycle power supply.
WATER
packaged unit
number
cross l=B=R
output Mbh
l=B=R burner capacity
gph
tankless heater number
l=W=H
rating
net I=B=R rating
Mbh
net rating sq ft
water
''Trade Price with
standard equipment
approx. shipping
weight
chimney size
Packaged units with factory installed tankless heater: With R8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control.
APT-95 APT-130 APT-165
95 .95 218 2% 82.6 550 $491.00 496 8x8x15
130 1.25 222 3 V, 113.0 753
550.00
580
8x8x 15
165 1.60 230 3% 143.5 956 629.00 647 8x8x15
Packaged units less heater With L4080B Aquastat limit control, and separate R8184G light sensing primary control.
AP-95 AP-130 AP-165
95 .95 130 1.25 165 1.60
82.6 113.0 143.5
550 $458.00 753 513.00 956 590.00
Nozzle sizes, gph. 60* solid, furnished with the above units: AP(T)-95. 0.90; AP(7)-130. 1.25; AP(T>-165. 1.50.
Gallons of water per minute from 40F to I40*F with 200'F boiler water temperature
481 565 632
8x8x 15 8x8x15 8 x 8x 15
HH-ll See page 56
Standard equipment:
Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads.
T822D thermostat. Light weight insulating fire brick combustion chamber.
Nozzle. Draft regulator. ASME relief valve.
Pressure and temperature gauge.
1%" circulator with piping. Wiring harness. Drain valve.
Note: Units are shipped with flush jacket and with all electrical controls (except thermo stat), circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately. Draft regulator, relief valve and thermostat shipped inside boiler crate.
Two-stage fuel unit is available for DH-5
oil burner. Specify on Order.
Added Trade Price
$6.15
Ordering Examples: 1. Packaged unit with heater 1 APT-130
2. Packaged unit less heater 1 AP-95
I
Page 18
02418
ryi AMERICAN IS STANDARD
HYDRONIC HEATING
PACKAGED BOILER-BURNER UNITS
WATER
A-3 PACKAGED BOILER-BURNER UNITS
Where quality, performance and packaged convenience are required, it's the A-3 all the way. Completely packaged and pre-wired, and crated to handle easily on that next job. Available with or without top performing tankless heater, the A-3 features the American-Standard built and backed DH Arcoflame oil burner for years of troublefree service. Wet base construction assures top perform ance; quality controls and accessories sell themselves. New improved ratings are achieved with present DH-5 oil burner having 1,725 rpm motor.
Furnished with controls for forced circulation, the A-3 is tested and eouipped for 30 lbs. water working pressure. Unit is arranged to operate on 115 volt, 60 cycle power supply.
WATER
packaged
unit number
gross l=B=R
output Mbh
l=B=R burner capacity
gph
tankless heater number
l=W=H
rating
net l=B=R
rating Mbh
net rating
sq ft water
"Trade
Price with standard equipment
approx. shipping
weight
chimney size
Packaged units with factory installed tankless heater. With R8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control.
A-33M-PT
108 1.00 222 4
93.9 626 $591.00
735 8 x8x 15
A-34M-PT
148 1.35 230 4
128.7
858 684.00
818 8x8* 15
A-35M-PT
188 1.70 328 4 V,
163.5
1090
785.00
956 8x8x 15
Packaged units less heater: With R8182F Aquastat combination, limit and circulator control, light sensing primary"control, one heater opening cover plate.
A-33M-P
108 1.00
93.9 626 $558.00 720 8x8x 15
A-34M-P
148 1.35
128.7 858 649.00 801 8 x 8 x 15
A-35M-P
188 1.70
163.5
1090
739.00
944 8x8x 15
Nozzle sires, 9Ph, 70 solid, furnished with the above units: A-33, 1.00; A-34, 1.35; A-35, 1.75. A Gallons of water per minute heated from 4CTF to 140*F with 200*F bo.ler water temperature
Standard equipment:
Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. T822D thermostat.
Scientifically designed pre-cast refractory combustion chamber. Nozzle Draft regulator. ASME relief valve. Pressure and temperature gauge. IV4" circulator with piping. Wiring harness.
Drain valve. Optional equipment: See page 22.
Note: Units are shipped with flush jacket and with all electrical controls (except thermo stat), circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately. Draft regulator, relief valve and thermostat shipped inside boiler crate.
Zone valve packages are available for water boilers. For details and prices, see page 34. Ordering Examples:
1. Packaged unit with heater with optional equipment:
1 A-33 M-PT boiler-burner unit with jacket extension
2. Packaged unit less heater with standard equipment:
1 A-34 M-P boiler-burner unit
'W See page 56
Page 19
HH-11
02419
BOILER-BURNER UNITS
WMEt AND STEAM
rSl AMr''ICAN kSJSTA OARD
HYDRONIC HEATING
A-3 NON-PACKAGED ALL-PURPOSE BOILER-BURNER UNITS
If you prefer your oil-fired boilers unpackaged for convenience and flexibility, choosr the A-3 Non-Packaged Boiler-Burner unit in one of five sizes for water or steam, with or without tankless heater. This boiler offers you A-3 versatility. It can be used on forced circulation or gravity systems or steam. New improved ratings are achieved with present DH-5 oil burner having 1,725 rpm motor.
The flush jacket installs easily and provides free access to all controls and burner for quick adjustment and servicing.
The factory assembled sections are tested and equipped for 30 lbs. water working pres sure. Motor and controls are regularly furnished for 115 volt, 60 cycle power supply
WATER
boilerburner
unit number
gross l=B = R output
Mbh
l=B = R burner
capacity
) gph
tankless | heater
1 number
l=W==H
rating
net
rating Mbh'
net rating
sq ft water
Trade Price with
standard equipment
approx. shipping
weight
J_____________
chimney size
Forced circulation units with factory installed tankless heater: With R8182D Aquastat relay combination, high
limit, low limit and circulator control, light sensing primary control.
A-33M-WBT 108 k. A34M-WBT 148
1.00 1.35
222 4 230 4
93.9 128.7
626 858
1 A-35M-WBT 188 1.70 328 4v, V A-36M-WBT 228 2.20 335 5>/2
163.5 198.3
1090 1322
A-37M-WBT 268 2.50 335 5Vz___ 233.0 1553
$480.00 573.00
674.00 770.00 860.00
666 756 878 1016 1148
8x8x15 8x8x 15
8x8x15 8x8x15 8 x 12 x 15
Forced circulation units less heater: With R8182F Aquastat combination, limit and circulator control, light sensing primary control.
A-33M-WB A-34M-WB A-3SM-WB A-36M-WB
A-37M-WB
108 148 188 228
268
1.00
1.35 1.70 2.20 2.50
93.9 128.7 163.5 198.3 233.0
626 658 1090 1322 1553
$447.00 536.00 626.00 719.00 809.00
658 740 875 1005 1138
8x8x 15 8 x 8 x 15 8x8x15 8x8x15 8 x 12 x 15
Gravity units less heater: With L4080A Aquastat limit control, and separate R8184G light sensing primary control.
A-33M-WBG A-34M-WBG A-35M-WBG A-36M-WBG A-37M-WBG
108 148 188 228 268
1.00 1.35 1.70 2.20 2.50
93.9 128.7 163.5 198,3 233.0
626 858 1090 1322 1553
$443.00 534.00 624.00 715.00 805.00
657 739 874
1004 1137
8 x 8 x 15 8 x 8 x 15 8 x 8 x 15
8 x 8 x 15 8 x 12 x 15
STEAM
boiler-
burner
unit number
gross l=B=R output
Mbh
l=B=R burner capacity
gph
tankless heater number
l=WsH
rating
net
l=B=R rating Mbh
net |=B=:R
sq ft steam
Trade
Price with standard equipment
approx. shipping
weight
chimney size
Steam units with factory installed tankless heater: With PA404A Pressuretrol, L4006A Aquastat operating control, and separate R8184G light sensing primary control.
A-33M-SBT 108 1.00 222 3`A
81.0 338 $480.00
A-34M-SBT 148 1.35 230 3>/z
111.0
463
573.00
A-3SM-SBT 168 1.70 328 41/4
141.0
588
674.00
A-36M-SBT 228 2.20 335 4V4
171.0
713
770.00
A-37M-SBT 268
2.50
335 5>/4
201.0
838
860.00
667 752 879 1017
1149
8x8x 15 8x8x 15
8x8x15 8x8x 15 8x 12 x 15
Steam units less heater: With PA404A Pressuretrol, and separate R8184G light sensing primary control.
A-33M-SB A-34M-SB
A-35M-SB A-36M-SB A-37M-SB
108 148
188 228 268
1.00
1.35 1.70 2.20 2.50
81.0 338 $443.00
111.0
463
534.00
141.0
588
624.00
171.0
713
715.00
201.0
838
805.00
658 740 875 1005 1138
8x8x 15 8x 8x 15 8x 8x 15 8x8x 15 8x 12 x 15
-Nozzle sizes, gpn, 70 solid, furnished with the above units: A-33, 1.00: A-34, 1.35; A-35, 1.75; A-36, 2,25; A-37, 2.50.
AGalions of water per minute heated from 40F to 140-F with 200"F bo ler water temperature
Standard equipment:
Zone valve packages are available for water boilers. For details and prices, see page 34.
Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads T822D thermostat.
Scientifically designed pre-cast refrac
tory combustion chamber. Nozzle. Draft regulator. Drain valve. Units WITH water heater 1 cover plate with V4" control tapping Units LESS heater: 2 cover plates for heat
er openings.
Ordering Examples:
1 All-Purpose boiler-burner unit with slandord equipment for forced circulation, with heater 1 A-37M-W&T boiler-burner unit For gravity circulation 1 A-33M-WBG boiler-burner unit
2 All-Purpose boiler bu rner unit with optional equipment For forced circulation, less heoter 1 A-35M-WB boiler-bur net unit with two stoge fuel unit
Water: ASME relief valve. Pressure and temperature gauge.
Steam: ASME safety valve. Steam gauge Gauge glass with trimmings.
Optional equipment: See page 22
HH-11
Page 20
See page 56
^AMERICAN bd STANDARD
HYDRONIC HEATING
OIL FIRED BOILERS
WATER AND STEAM
A-3 ALL-PURPOSE OIL FIRED BOILERS
For the boiler that spells quality and dependability, look no further than the A-3 with factory-assembled cast iron sec tion assembly that is tested and equipped for 30 lbs. water working pressure. The flush jacket slips on easily. This boiler provides outstanding performance.
WATER
boiler number
gross l = B=R output
Mbh
l=B=R burner capacity
*ph
tankless heater
number
A rating
net l=B=R rating
Mbh
Boiler with factory installed tankless heater--forced circulation
net rating
sq ft
water
Trade Price
approx shipping
weight
chimney size
A-33M-WT 108 1 00 222 4
93 9 626
A-34M-WT 148 1 35 230 4
128 7
858
A-35M-WT
188
1 70 328 4V.
163 5
1090
A-36M-WT 228 2 20 338
, 198.3
1322
A-37M-WT 268 2 50 335 5 V. j 233.0 1553
$315.00 408.00 509.00 605.00 695.00
613 698 825 962 1093
8x8x 15 8x8x15 8x8x15 8x8x15 8 x12 x15
Boiler less heater--gravity or forced circulation
A-33M-W A-34M-W A-35M-W A-36M-W A-37M-W
108 148 188 228
___2_6_8_ _
STEAM
1.00 1.35 1.70 2.20 2 50
boiler number--
gross l=B=R
output Mbh
l=B=R burner
capacity fph
tankless heater
number
A. I=W=H
rating
Boiler with factory installed tankless heater
93.9 128 7 163.5 198.3 233.0
net !=B=R rating
Mbh
626 858 1090 1322 1553
$290.00 381.00 471.00 562.00 652.00
605 687 822 951 1083
net l=B=R
sq ft steam
yr Trade Price
approx. 1 shipping j weight
8 x 8 x 15 8x8x 15 8 x 8 x 15 8 x 8 x 15 8 x12 x 15
chimney size
A-33M-ST 108 1 00 222 3`A A-34M-ST 148 1.35 230 3*/2 A-35M-ST 188 1 70 328 4'/.
A-36M-ST 228 2.20 335 4Vx A-37M-ST 268 2.50 335 5%
81.0 111.0 141.0 171.0 201.0
338 463 588 713 838
$315.00 408.00 509.00 605.00 695.00
614 699 826 963 1094
1 j
8x8x 15 8x8x 15 8 x 8 x 15 8 x 8 x 15 8 x 12 x 15
8oiler less heater
A-33M-S A-34M-S A-35M-S A-36M-S A-37M-S
108 1 00 148 1 35 188 1.70 228 2.20 268 2 50
81.0 338 $290.00
606 8x8x15
111.0
463
381.00
688 8x8x15
141.0
588
471.00
823 8x 8x 15
171.0
713
562.00
952 8x 8x 15
201.0
838
652.00
1084 8 x12 x15
A Gallons of water per minute heated from 4CTF lo 140F with 200'F boiler water temperature
Only l = B=R approved oil burners, such as the DH-5 burner, may be used wftn A-3 oil fired boilers. Other l = B = R approved burners are available. Consult your American Standard District Office for details
Standard equipment; Scientifically designed pre-cast refrac tory combustion chamber. Drain valve
Water: ASME relief valve Pressure and temperature gauge
Steam: ASME safety valve Steam gauge Gauge glass with trimmings Optional Equipment, See page 22
A 3j A 37 Sdiu Assernui'es J*aiiooie ,it aoaeo i r aoe once c nar qe ot $16.00
Note: Boilers with factory installed tankless heater aie shipped with one water heater opening cover plate with 3/4" control tap ping Boilers less factory installed heater are shipped with an additional water heater opening cover plate (blank).
Zone valve packages are available for water boilers. For details and prices, see page 34
Ordering txample$
1. Woter boiler leis heoter with jtandord equip ment
) A-34M-W bdier
2 Steam boiler with heoter with stondard equip ment
1 A-36M-ST boiler 3 Water boiler with heoter with optional equip
ment 1 A 35M WT boiler with jacket extension
Page 21
HH-11
02421
BOILER-BURNER UNITS OIL FIRED BOILERS
WATER AND STEAM
rSl AMERICAN ISJSTANDARD
HYDRONIC HEATING
A-3 OPTIONAL EQUIPMENT
FOR A-3 BOILER-BURNER UNITS AND OIL FIRED BOILERS
Jacket extension: Jacket extension provides 16%" enclosure
in front for concealment of oil burner and controls. Approx
imate shipping weight 35 lbs. Specify on order. Added Trade
Price
$32.33
McDonnell & Miller No. 67AR low water fuel cut-off for quick hook up installationis available for A-3 steam boilers at added TradePrice of.......................................$31.15
Controls and control sets are shown on page 35.
The No. 5Z Control Set can be used for circulator zoning
with A-3 boiler-burner units with tankless heater. X No. 5Z
set is required for each zone in addition to the first zone
which is controlled by the No. 5 Control Set or equivalent.
Added Trade Price
$27.60
FOR A-3 PACKAGED AND ALL-PURPOSE BOILER-BURNER UNITS
Two-stage fuel unit is available for DH-5 oil burner at added Trade Price charge of...........................................................$6.15
For substitution of No. 4 control set consisting of T822D
thermostat, L4081B Aquastat limit and circulator control,
plus R8184G light sensing primary control, instead of
R8182F combination control, for non-packaged A-3 boiler-
burner units for forced circulation LESS heater. Added
Trade Price ........................
$12.45
For substitution of No. 5 control set consisting of T822D
thermostat, L8124C Aquastat, limit, reverse and operating
control, circulator relay, plus R8184E light sensing primary
control, instead of R8182D combination control, for non-
packaged A-3 boiler-burner units for forced circulation
WITH tankless heater. Added Trade Price
$4.90
Order R8182D Aquastat-relay combination instead of
R8182F control to permit use of tankless heater with A-3
non-packaged boiler-burner units furnished less water
heater. Added Trade Price
$9.90
Order R8182E Aquastat-relay combination instead of
R8182F control to provide room thermostat control of
circulator. Added Trade Price
$5.40
l=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR A-3
Heaters tested with boilers.
Built-in tankless heaters can be ordered for separate shipment with units or boilers specified less heater as follows:
unit no.
1=B=R burner capacity
CPh
heater no.
l=W=H rating
water
steam
''Trade Price
A-33 A-34 A-35 A-36 A-37
1.00
1.35 1.70 2.20 2.50
222 230 328
335 335
4
4
4% 5% 5%
3Vz 3*/2 4 Vi 4%
5>/4
$28.00 30.00 41.00 46.00 46.00
Gallons of water per minute heated from 40aF to 140*F with 200*F boiler water temperature.
HH-11 See page 56
Page 22
AMERICAN
kSiSTANDARD
HYDRONIC HEATING
pressure fired
boiler-burner units
WATER AND STEAM
PFA-3 PRESSURE FIRED BOILER-BURNER UNITS
The PFA-3 Pressure Fired Boiler is forced-draft with flame retention burner using No. 2 oil for over 80% efficiency. Attractive two-toned brown and beige jacket with optional matching acoustically treated jacket extension. Wet base construction eliminates need for separate base. Perfect seal between boiler sections is achieved with durable sealant. Factory assembled sections are tested and equipped for 50 lbs. water working pressure Motors and controls regularly furnished for 116 volt, 60 cycle power supply.
WATER
belter-
buurnniet r
number
gran Islsl
output Mbh
.
*
l = B=* burner copoclty
gph
ttmkleii heater number
+ l = W=H
rating
l =nBe=t * rating Mbh
net
rating eq. ft.
water
Trade Price with itondard equipment
approx.
shipping weight
e
rent sire
dlam. In.
Forced circulation units with factory Installed tankless heater: No. 5 control set -- T822D thermostat, L8124C Aquastat.
reverse and operating control, circulator relay, R8184G light sensing primary control.
PFA-34-WT
300
2.65 226
6.0
260.9
1739
3 907.00
905 8
PFA-35-WT
375
3.30 232
7.5
326.1
2174
1026.00
1096
8
PFA-36-WT
450
3.95 445
9.0
391.3
2609
1150.00 - 1287
8
PFA-37-WT
526
4.60 445
9.0
457.4
3049
1262.00
1481
8
Forced circulation units less heater: No. 4 control set --T822D thermostat, L4081B Aquastat limit and circulator control
R8184G light sensing primary control.
PFA-34-W PFA-35-W PFA-36-W PFA-37-W
300 2.65 375 3.30 450 3.95
526 4.60
260.9 326.1 391.3 457.4
1739 2174 2609
3049
$ 859.00 970.00
1081.00 1193.00
894 1085 1276 1470
8 8 8 8
STEAM
1*1
beilerburner
unit
number
grail
l = B= output
Mbh
*
Istst burner capacity
Bph
lankiest
heater number
t
1 = W=H rating
net 1 = 8=1
rating Mbh
net l=B = R
*q. ft. steam
'W' Trode Price with
standard
equipment
approx.
shipping
weight
vent sice dfam. in.
Steam units with factory Installed tankless heater: No. 2 control set -- T822D thermostat. PA404A Pressuretrol, L4006A Aquastat operating control, R8184G light sensing primary control.
PFA-34-ST
300 2.65 226 6.0 225.1 938 $ 899.00
905 8
PFA-35-ST
375
3,30 232
7.5
281.3
1172
1018.00
1096
8
PFA-36-ST
450
3.95
445
9.0
337.6
1407
1143.00
1287
8
PFA-37-ST
526
4.60
445
9.0
394.6
1644
1254.00
1481
8
Steam units less heater: No. 1 control set--T822D thermostat, PA404A Pressuretrol, R8184G light se nslng prlma ry control.
PFA-34-S PFA-35-S PFA-36-S
PFA-37-S
300 2.65 375 3.30 450 3.95 526 4.60
225.1 281.3 337.6 394.6
938 1172
1407 1644
$ 848.00
959.00 1071.00 1182.00
900 1091 1282
1476
8 8
8 8
Nozzle sizes furnished with the above units: (S -- solid: H -- hollow) PFA-34, 2.50 gph 45 H; PFA-35, 3.25 gph 45 S; PFA-36, 4.00 gph 45 S; PFA-37, 4.50 gph 30 S.
tGallons of water per minute heated from 40F to 140F with 200F boiler water temperature.
Vent needs to extend only 3 feet above highest part of roof.
Standard Equipment
Water: ASME relief valve Pressure and temperature gauge
Flange mounted oil burner with 2-stage fuel unit; factory installed light sensing
cad cell with bracket and leads; V4046B
instantaneous oil valve; Syracuse elec tronic time delay; drain valve.
boiler-burner
unit
PFA-34 PFA-35
oil burner
LC-334-A3 LC-334-A
boilarbvrMr
Ultlf
PFA-36)
PFA-37 f
oil burner LC-534-A
Steam: ASME safety valve Steam gauge Gauge glass with trimmings
Optional Equipment
Available in split assemblies. Specify on order. Added Trade Price . . $16.00 For other optional equipment see page 24.
Units WITH water heater: 1 cover plate
with
control tapping.
Units LESS water heater: 2 cover plates for heater openings.
Ordering Examples:
1. Pressure fired boiler-burner unit with standard equipment with heater for water: 1 PfA-34-WT boiler-burner unit
2. Pressure fired boiler-burner unit with op tional equipment less heater for steam: 1 PFA-37-S boiler-burner unit with jacket extension
HH-11 W See page 56
Page 23
Zone valve packages are available for water boilers. For details and prices, see
page 34.
02423
PRESSURE FIRED BOILER-BURNER UNITS
WATER AND STEAM
S_i
AMERICAN STANDARD
HYDRONIC HEATING
PFA-3 OPTIONAL EQUIPMENT
Acoustically treated brown and beige jacket extension: Jacket extension provides 17};" enclosure in front for con cealment of oil burner and controls. Approximate shipping weight 42 lbs. Specify on order. Added Trade Price $38.00
No. 5-Z control set for circulator zoning with PFA-3 boiler-
burner units equipped for tankless heater. 1 No. 5-Z set is
required for each zone in addition to the first zone which is
controlled by the No. 6 control set or equivalent. Trade
Price of
$27.60
McDonnell & Miller No. 67AR low water fuel cut-off for quick hook-up installation is available for PFA-3 steam units at added Trade Price of........................................ $31.15
McDonnell & Miller No. 63 low water cut-off is available for PFA-3 water units at added Trade Price of ...... $42.75
Controls and control sets are shown on page 35.
I=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR PFA-3
Heaters tested with boilers. Built-in tankless heaters can be ordered for separate shipment with units or boilers specified less heater as follows:
unit no.
PFA-34 PFA-35 P FA-36 PFA-37
l=B=R burner capacity Bph
2.65
3.30
3.95
4.60
heater no.
226 232 445 445
| = W =H rating
water
team
6.0 6.0 7.5 7.5 90 9.0 9.0 9.0
pressure drop thru heater
at rated flew
23 psi 36 psi 37 psi 37 psi
Trade Price
$40.00 48.00 61.00 61.00
Goffoni of wafer per minute from dOrF lo 14C*F with 200*F boiler woler iempra>u'e
HH-11 See page 56
Page 24
* 02424
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
PFA-5 Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 809c- efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 60 lbs. water working pressure; 80 lbs. water working pressure is optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good steam quality. Vent needs to extend only 3 feet above highest part of roof.
OIL BOILER-BURNER UNITS
STEAM ANO WATER
pressure fired boiler-burner unit number
oil
1 --B=R
grot*
burner
1 = B = * copodty
Mbh oil SPh
PFA-504-* O(T) PFA-505-* O(T) PFA-506-* O(T)
620 786 950
5.45 6.90 8.35
PFA-507-* 0(T) PFA-50B-* 0(T) PFA-S09-* O(T)
PFA-510-* O(T) PFA-511-* O(T) PFA-512-* O(T)
1116 1282 1446
1612 1776 1944
9.80 11.20 12.65
14.10 15.55 16.95
PFA-513-* 0(T) PFA-514-* O(T) PFA-515-* O(T)
2108 2272 2440
18.40 19.85 21.25
PFA-516-* O(T) PFA-517-* O(T) PFA-51B-* O(T)
2604 2768 2936
22.70 24.15 25 60
PFA-519-* O(T) PFA-520-* O(T) PFA-521-* O(T)
3100 3260 3430
22,00 28.45 29.90
piping nd pickup fc
steam
water
nei t = 0 -- R rating
Mbh steam water
sq. ft. steam
1 333 1.333 1.333
1.333 1.330 1.315
1.15 1.15 1.15
465 1 589.6 712.7
539.1 683.5 826.1
1.15 837.2 970 4 1.15 963.9 1114.8 1.15 1099.6 1257.4
1938 2457 2969
3488 4016 4582
1.302 1.292 1.2B8
1 15 1238.1 1401.7
1.15 1374.6 1544.3
1.15 1509.3 1690.4
5159 5728 6289
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7
1.15 2021.7 2264.3 1.15 2149.1 2407 0 1.15 2279.5 2553.0
1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982.6
6819 7350 7893
8424 8954 9498
10028 10546 11096
net
rating sq. ft. water
Trade Price with standard equipment
ell
vent size diom. in.
opprov-
Imote shipping weight
burner model supplied with standard equipment
ell
3594 4557 5507
*1406.00 10 1683.00 10 1853.00 10
1840 2210 2520
95A-1-8702-JA-T 96A-M-6131-J-T 96A-M-6131-J-T
6469 7432 8383
2151.00 10 23B6.00 10 2556.00 14
2880 3190 3550
96A-B-8316-JC-T 96A-B-8317-JC T 96A-B-8318-JC-T
9345 10295 11269
2993.00 14 3461.00 14 3738.00 14
3935 4285 4645
96A-T-A-8419-J-T 97A-T-A-8613-J-T 97A-T-A-8614-J-T
12220 13171 14145
3909.00 14 4111.00 14 4398.00 14
4955 5317 5675
97 A-T -A-8614-J-T 97A-T-A-8615-J-T 97A-T-2-7635-E-1
15095 16047 17020
4729.00 18 4931.00 18 5197.00 18
5985 6345 6750
97A Hi-Lo-2-7685-E-1 97A Hi-Lo-2-7685-E-1 98A H.-LO-2-7771-E-1
17971 18899 19884
5442.00 18 5623.00 18 5836.00 18
7060 7420 7780
98A-H(-Lo-2-7771-E-1 98A H.-Lo-2 7771-E-l 98A Hi-Lo-2-7771-E-1
The net tr=B=R ratings shown are based on piping and pick-up allowances listed above. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements.
`Substitute letter "S" for steam; "W" for water. Start Up and One Year's Service . . . Price on Application Suffix (T) denotes boiler with openings in center section for tankless heaters when specified. For Built-in Water Heaters, see page 28.
# Nozzle sizes, gph, furnished with the above oil burners are as follows:
unit na. gph. type
unit no. gph. type
unit no. gph. type
unit no. gph. typ*
unit no. gph. type
unit no. gph. type
PFA-504 2 2.75 90H PFA-505 2 3.50 90* H PFA-506 2 4.00 80 *H PFA-507 1 4.50 70H
1 5.00 70"H
PFA-508 2 5.50 80*H
PFA-509 1 6.00 80`H PFA-512 2 7.00 70H PFA-514 1 3.50 60 H PFA-517 1 10.00 90S PFA-520 1 8.00 80$
1 6.50 80H
1 2.50 70 H PFA-515 2 8.00 70H PFA-51B 1 7.50 90S
1 8.50 80S
PFA-510 2 5.50 90*H PFA-513 2 7.00 70H
1 5.00 70H
1 8.00 90S
1 12.00 80S
1 2.75 90H
1 4.00 70 H PFA-516 2 7.00 90S
1 10.00 90S PFA-521 2 8.00 80S
PFA-511 2 6.50 80H
1 8.50 90S PFA-519 2 7.50 80S
1 14.00 80S
1 2.00 80H PFA-514 2 8.00 60H PFA-517 2 7.00 90S
1 12.00 80S
Standard Equipment--All Boilers
Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve.
Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve.
Standard Equipment--Oil Fired
Flange mounted oil burner--97A-T-A, 97A-T-2, 97A Hi-Lo
and 98A Hi-Lo burners furnished with flange and pedestal; 2-stage fuel unit. One 95A-1, 96A-M, 96A-B, 96A-T-A and 97A-T-A burners, factory installed cad cell, bracket and leads, R8185E light sensing primary control; V4046B in stantaneous oil valve, ST70A1002 electronic time delay. On 97A-T-2, 97A Hi-Lo-2 and 98A Hi-Lo-2 burners, R4150A
control--provides pre-purge and post-purge, Q520A base, factory installed C7013A photo cell; delayed and instantan eous oil valves, nozzles.
Standard Motor Voltages
PFA-504 thru PFA-610
116/60/1
PFA-511 thru PFA-521
230/60/1
Ordering Examples:
PFA-5 boiler-burner unit for steam with standard equipment.
1--PFA-514-SO boiler-burner unit
PFA-5 boiler-burner unit for wafer with optional equipment
1 -- PFA-511 -WO(T) with jacket extension; 4 No. 548 tankless
heoters; with L6006A control
Optional Equipment--Oil Fired
Oil Burners equipped to meet F.M. and Massachusetts Code
requirements for PFA-504 through PFA-514 Units are
available when specified on order.
Added Trade Price
$159,00
Burners for PFA-515 through PFA-521 already equipped to meet F.M. requirements. Equipment includes: R4150A pro vides pre- and post-purge, C7013A Photo Cell and Q520A Base.
Oil Burners to meet F.I.A. requirements--Price on applica tion.
Oil burners for PFA-515 thru PFA-521 to meet Massa chusetts Code requirements -- Price on application.
Optional burners available forPFA-504 thru PFA-510. see page 28.
See page 56
Page 25
HH-11
02425
GAS BOILER-BURNER UNITS
STEAM AND WATER
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
PFA-5 Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 80% efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure is optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good
steam quality.
preiture fired boiler-bumer unit number
groii
I =B =*
output Mbh
PFA-504-* G(T) PFA-505-* G(T) PFA-506-' G(T)
PFA-507-' G(T) PFA-S08- G(T) PFA-509- G(T)
PFA-51D-' G(T) PFA-511-' G(T) PFA-512- G(T)
PFA-513- G(T) PFA-514- G(T) PFA-515- G(T)
PFA-516-* G(T) PFA-517-* G(T) PFA-516-* G(T)
PFA-519-* G(T) PFA-520-* G(T) PFA-521-* G(T)
620 786 950
1116 1282 1446
1612 1776 1944
2108 2272 2440
2604 2768 2936
3100 3260 3430
--Il =1 =* burner
piping irtd
capocity pickup
input Mbh
steam
s|=t rot
Mbh
iq. it.
toam
763 966 1169
1372 1568 1771
1974 2177 2373
1.333 1.333 1.333
1.333 1.330 1.315
1.302 1.292 1.288
1.15 1.15 1.15
465.1 589.6 712.7
539.1 683.5 826.1
1.15 837.2 970.4 1.15 963.9 1114.8 1.15 1099.6 1257 4
1.15 1238.1 1401.7 1.15 1374.6 1544.3 1.15 1509.3 1690.4
1938 2457 2969
3488 4016 4582
5159 5728 6289
2576 2779 2975
1.288 1.288 1.288
1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7
6819
3178
3381 3584
1.288 1.288 1.288
1.15 2021.7 2264.3 1.15 2149.1 2407.0 1.15 2279.5 2553.0
3786 I 3983 I 4186
1.288 1.288 1.288
1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982.6
net rating q. ft. wetsr
3594 4557 5507
6469 7432 8383
9345 10295 11269
12220 13171 14145
15095 16047 17020
17971 18899 19884
Trade
Price with itandard equipment
go*
approx imate
lie Uhlpping
burner model igpplied with standard equipment
gat
$2216.00 2435.00 2644.00
2960.00 3206.00 3376.00
3822.00 4353.00 4648.00
4836.00 5038.00 5230.00
5554.00 5756.00 5938.00
6312.00 6493.00 6706.00
10 10 10
10 10 14
14 14 14
14 14 14
18 18 18
18 18 18
1840 B6 2-G-03-R4795-B 12S 2210 R6.2-G-03-R4795-B.12S 2520 R6.2-G-03-R4795-B.12
2880 R8-G-05-R4795-B.12 3190 R8-G-05-R4795-B.15 3550 R8-G-05-R4795-B.15
3935 R8.1-G-05-R4795-B.20 4285 R8.2-G-05-4150A-H.20 4645 R8.3-G-10-4150A-H.20
4955 5315 5675
R10.9-G-1CM150A-H.20 R10.9-G-10-4150A-H.20 R10.9-G-10-4150A-H.20
5985 6345 6750
R10-G-15-4150A-H.25S R10-G-15-4150AH.25S R 10.1-G-15-4150A-H.25S
7060 R10.1-G-2a4150A-H.25 7420 R10.l-G-2a4150A-H.25
7780 R10.1-G-20-4150A-H.25
The net t = B=R rating! shown are based on piping onu K.---------------selecting a boiler for installations having unusual piping and pick-up requirtmen s.
Sb.ti,t. I.tt.r "S" for .fm, "W" for wo,or START-UP AND ONE YEAR'S SERVICE: INCLUDED IN TRADE PRICE OF GAS UNIT ,1, Suffix (T) denote, boiler with opening, in center section for ,ankle,, heater, when ,pec,fled. For Bu,l..,n Worer Heoter,. ,e. poge 28
Standard Equipment--All Boilers Steam: PA404A Pressuretrol, ASME safety valve, steam
gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat, ASME relief valve, pressure and
temperature gauge, drain valve.
Standard Equipment--Gas Fired Flange mounted gas burner. Standard burner controls meet latest UL requirements. Dual automatic gas valves for added reliability. Gas-electric ignition. Electric program ming controls and components are factory wired in a con trol cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burners equipped to operate with 1,000 Btu, 0.6 specific gravity natural gas.
Ordering Examples: PFA-5 boiler-burner unit for steam with standard equipment. 1--PFA-514-SG boiler-burner unit PFA-5 boiler-burner unit for water with optional equipment. 1"PFA-511-WG(T) with jacket extension; 4 No. 548 tankless heaters.
Specify gas pressure available at gas train inlet.
(1) Surcharge for SlarMJp and Service west of Mississippi River.
Contact American-Standard for details.
Optional Equipment
Factory assembled sections available. Specify on order.
Added Trade Price -- Per section
$21.00
PFA-5 units are available with controls to meet Factory Mutual and Factory Insurance Association requirements at
the following added charges:
got tired
boiler six*
f *M.
F.I.A.
PFA-504--510 PFA-511--515 PFA-516--521
$710.00 541.00 562.00
$875.00 779.00 806.00
For prices of gas burners for use with other than 1000
Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature,
consult your American Standard District Office.
Hi-Lo Fire Control .....................................
Modulating Fire Control......................... Alarm System pre-wired and mounted on
control cabinet............................................
Optional Combustion Controls ...............
Price on
Application
Controls to meet local requirements .......
For Additional Optional Equipment, See page 28
Standard Motor Voltages
The complex nature of the Gas and Gas-Oil Burners make them imprac tical to stock at Bond Plant. Therefore, please allow 3 to 4 weeks lea^ time for shipment of Standard Equipped Burners after receipt of order
at Hydronie Order Service Center.
unit number
get burner*
PFA-504--511 PFA-512-521
115-60-1 230-60-3
Other optional motor voltages--Price on Application.
HH-11 See page 56
Page 26
02426
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
GAS--IIGHT OIL BOILER-BURNER UNITS
I'K \-f> Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for o\*.-r hOf;v efficiency and outstanding performance. Combustion chamber and separate base are not. required due to wet base design. Minimum stack required making boiler ideal for replace ment Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure is optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good
steam quality.
Vent needs to extend only 3 feet above highest part of roof.
pretture fired boiler-bumer unit number
gat--light oil
a ai = -- |
grott =B =l
burner ropority
,
output Mbh
got input
Mbh
piping and actor
iteom
water
PFA-504-- GO(T) PFA-505-* GO(T)! PFA-S06-* GO(T)
620 763 786 966 950 1169
1 333 1.333 1 333
1 15 1 15 1 15
net 1 = B = R rating
hMb
steam water
iq. ft team
_________ j
465.1 589.6 712 7
539 1 683.5 826.1
1938 2457 2969
net rating sq ft. water
3594 4557 5507
^Irode Price with standard equipment
go*--ell
$2606.00 2824.00 3106.00
vent
site
dlam. in.
10 10 10
approx imate shipping weight
burner mdel supplied with itandard equipment
a.
ga*--oil
1840 2210 2520
R6 2-G0 03-R4795-B 12S-FIC R6.2-GO-03-R4795-B. 12S-F 1C R6.2GO-03-R4795-8.12-FIC
PFA-507-* GO(T) 1116 1372 PFA-508-* GO(T) 1282 1568
PFA-509-* GO(T) 1446 1771
1 333 1 330 1.315
1.15 837.2 970 4 1.15 963.9 1114.8 1.15 1099.6 1257.4
3488 4016 4582
6469 7432 8383
3381.00 3678.00 3849.00
10 10 14
2880 3190 3550
R8-GO-05-R4795-B.12-F3 R8-G0-05-R4795-B. 15-F3 R8-GO-05-R4795-B.15-F3
PFA-510-* GO(T) PFA-511-* GO(T) PFA-512-* GO(T)
PFA-513-* GO(T) PFA-514-* GO(T) PFA-S15-* GO(T)
1612 1974 1776 2177 1944 2373
2108 2576 2272 2779 2440 2975
1.302 1.292 1 288
1.288 1.288 1.288
1.15 1238.1 1401.7 1.15 1374.6 1544.3 1.15 1509.3 1690.4
1.15 1636.6 1833 0 1.15 1764.0 1975.7 1.15 1894.4 2121.7
5159 9345 5728 10295 6289 11269
6819 12220 7350 13171 7893 14145
4332.00 4690.00 5049.00
5240.00 5442.00 5634.00
14 14 14
14 14 14
3935 4285 4645
4955 5315 5675
R8.1-GO-05-R4795-B.2O-F3 R8.2-GO-07-4150A-H.20-F4H R8 3-G0-10-4150A-H.20-F4H
R t0.9-GO-10-4150A-H.2O-F4H R10.9-GO-10-4150A-H.20-F4H R10.9-GO-10-4150A-H.20-F4H
PFA-516-* GO(T) PFA-517-* GO(T) PFA-51B-* GO(T)
PFA-519-* GO(T) PFA-520-* GO(T) PFA-S21-* GO(T)
2604 3178 2768 3381 2936 3584
3100 3780 3260 3983 3430 4186
1.288 1.288 1 288
1.288 1.288 1 288
1.15 2021.7 2264.3 1.15 2149.1 2407.0 1.15 2279.5 2553.0
8424 8954 9498
15095 16047
17020
1.15 2406.8 2695.7 1.15 2531 1 2834.8 1.15 2663.0 2982.6
10028 10546 11096
17971
18899 19884
5955.00 5158.00 6417.00
6728.00 6995.00 7208.00
18 18 18
18 18 18
5985 6345 6750
7060 7420 7780
R10-GO-15-4150A-H.25S-F4H R10-GO-1 5-4150A-H.25S-F4H R10 1-GO-20-4150A-H.25S-F4H
R10.1-GO-20-4150A-H.25-F4H R10 1 -GO-30-41 50A-H.25-F4H R10.1-GO-30-4150A-H.25-F4H
The net I =: B = R rating* thownw based on piping and pick-up allowances listed above. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements.
Substitute letter "S" for steam, "W" for water. START-UP AND ONE YEAR'S SERVICE: INCLUDED IN TRADE PRICE OF GAS-OIL UNIT.(l) Suffix (T) denotes boiler with openings in center section for tankless heaters when specified. For Built-in Water Heaters, see page 28
Standard Equipment--All Boilers
Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve.
Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve.
Standard Equipment--Gas-Light Oil Fired
Flange mounted combination gas-oil burner. Standard
burner controls meet latest UL requirements. Manually operated fuel switch for dual fuel change-over. Dual auto matic gas valves for added reliability. Gas-electric ignition. Electric programming controls and components are factory wired in a control cabinet on the burner. Includes R4795
control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burner equipped to operate on No. 1 or No. 2 fuel oil and 1,000 Btu, 0.6 specific gravity natural gas.
Standard Motor Voltages
uml number
gai-oil burner*
PFA-504--510
115-60-1
PFA-511 PFA-512-521
230-60-1 230-60-3
Other optional motor voltages--Price on Application.
(1) Surcharge for Start-Up and Service weft of Mississippi River. Contoct American-Standard far details.
Ordering Examples: PFA-5 boiler-burner unit for steam with standard equipment. 1--PFA-514-SGO boiler-burner unit. PFA-5 boiler-burner unit for water with optionol equipment. I-- PFA-511-WGO(T) with jacket extension; 4 No. 548 tankless heaters.
Specify gat pretture available at gat train inlet
dBaNozzte sizes, gph, furnished with combination gas-light oil burners are as follows: (nozzle capacity is dependent on oil pressure.)
unit no. gph. type
unit no. gph. type
unit no. gph. type
PFA-504 1 4.00 90H PFA-505 1 5 00 90H PFA-506 1 6.50 90H PFA-507 2 4.00 90S PFA-508 2 4.00 90S PFA-509 2 5.00 90S
PFA-510 2 5.00 90S PFA-511 2 5.50 90S PFA-512 2 6.00 90S PFA-513 2 7.00 60S PFA-514 2 7.00 60S PFA-515 2 7.00 60S
PFA-516 2 7.00 60S PFA-51 7 2 8.00 60S PFA-518 2 8.00 60S PFA-519 2 8.00 60S PFA-520 2 8.50 60S PFA-521 2 9.00 60S
Optional Equipment
PFA-5 units are available with controls to meet Factory
Mutual and Factory Insurance Association requirements at
the following added changes:
gos-oif fired
boffer sfse
f.M.
f t.A.
PFA-504--510 PFA-511 --515 PFA-S16-521
$685.00 710.00
731.00
$1018.00 928.00
928.00
Automatic Fuel Changeover Trade Priced............................................................. $183.00
For prices of gas-oil burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures
above or below pressures shown in current literature, consult your American Standard District Office.
Hi-Lo Fire Control............................................ Modulating Fire Control...........................
Price
Alarm System pre-wired and mounted on control cabinet.................................................
on
Optional Combustion Controls . .................... Application
Controls to meet local requirements . . .
The complex nature of the Gas and Gas-Oil Burners make them imprac tical to stock at Bond Plant. Therefore, please allow 3 to 4 weeks lead time for shipment of Standard Equipped Burners after receipt of order at Hydrome Order Service Center.
See page 56
Page 27
HH-11
02427
BOHER-BURNER units OIL FIRED BOILERS
WATER AND STEAM
rs\ AMERICAN Si STANDARD
HYORONIC HEATING
PFA-5 OPTIONAL EQUIPMENT
Jacket extension: Jacket extension provides 34 */" enclosure
ir front for concealment of burner and controls. Approxi-
iv.ii'* shipping weight 90 lbs Specify on order Added Trade
Price
$63.00
PFA-5 boilers tested for 80 lbs. water working pressure:
available when specified on order. Add to Trade Price of water boiler........................................................$8.00 per section
Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows:
PFA-5
.Trade Price each
$3.90
Optional burners to provide low fire start (with cad cell) for PFA504 thru PFA508; Hi-Lo operation provided (with cad cell) for PFA609 and PFA610. Please allow four weeks lead time after receipt of order at the hydronic order serv ice center.
unit
PFA 504 PFA 505 PFA 506 PFA 507 PFA 508 PFA 509 PFA 510
burner model
96A-T-A 8406-JJ30-T 96A-T A 8407 JJ30-T 96A-T-A 8408 JJ15 T 96A-T-A 8409-JJ15-T 96A-T-A 8410-JJ15 T 96A-HI LO-A-8808-JJ15-T 96A-HI UO-A-8808 JJ15-T
add le Trade Price
$126.00 113.00 119.00 57.00 57.00 256.00 198.00
Factory assembled sections available. Specify on order.
Added Trade Price per section
$21.00
TANKLESS WATER HEATERS FOR A-5, FRA-5 AND PFA-5
Tankless water heaters are available in any quantity at the following Trade Prices:
healer numb*'
wind with
Trode Pric loth
530 548
A-5. FR-A-5 PFA-5
$40.00 66.50
PFA-5 units with tankless water heaters require additional controls at current prices as follows:
STEAM: L4006A Aquastat operating control.
Trade Price
$14.05
WATER: L6006A Aquastat operating and circulator
control.
Trade pricc
$14.90
Factory assembled copper pipe manifold for parallel hook up of multiple heaters are available as follows:
manifold auembly
Trode Pnci lor A-5, FR-A-5
2 Heater 3 Heater 4 Heater
$ 8.20 12.00
15.25
When suffix "T" is added to boiler number on order for A-5, FR-A-5 or PFA-5 boilers or units, maximum number of centei sections with water heater openings are furnished at no extra charge as follows: Except where noted by asterisk in which case max. number of openings minus one is furnished unless max. number is specified on order.
A-5 and FR-A-5 belter
A-5 or FR-A-504 T
A-5 or FR-A-505-T thru 507-T A-5 or FR-A-508-T*thru 509-T A-5 or FR-A-510 T*thru 511-T*
max. no. of opening*
2 3 4 5
PFA-5 boiler
PFA-504T PFA-505-T thru 506-T PF A-507-T thru 508-T PF A-509-T thru 511-T
max. no. ol openings
1 2 3 4
PFA-5 boiler
PFA-512-T thru 514-T PFA-515-T thru 517-T PFA-518-T thru 519-T PF A-520-T thru 521-T
The following table shows ratings attained if more than one heater is connected in parallel:
lonkle** heeler no. 530
boiler number
no of heelers
! *ro1ing gpm.
boiler number
rankle** heoler No 546 no ol heater*
A-5 or FR-A-5-T all sizes A-5 or FR-A-5-T all sizes A-5 or F R-A-505-T thru 51 I T A-5 or F R-A-508-T thru 511-T
A-5 or FR-A-510-T thru 51 I T
1
i !
14 2 ;7 3 1 10 4 ! 13 5 ! 16
,
PFA-5-T all sizes PF A-505-T thru 506-T PF A-507-T thru 508-T
PF A-509-T thru 511 -T PFA-512-T thru 514-T PFA-515-T thru 517 T PFA-518-T thru 519-T PF A-520-T thru 521-T
1 2 3
5 6 7 8
Gollon* of wo'*' per minuie 'oued I'om 40*F lo 140F with 200F bo<ler wole' lemperaiure
mox. no of | openings
;1 65
!7 i8
j *rotmg gpm
!8 : is
24 i 32 1 40 i 48 i1 5664
McDonnell & miller low water cut-offs
STEAM: No. 369 Low Water Cut-off for A-5, FR-A-5, PFA-5 ...
-- --
No. 47-2 Feeder and Cut-off for A-5, FR-A-5, PFA-504 thruPFA-509
No. 51-2 Feeder and Cut-off for PFA-510 thru PFA-521
WATER--50 PSI: No. 63 Low Water Cut-qff for A-5, FR-A-5 andPFA-5
WATER--80 PSI: No. 150 Low Water Cut-off for PFA-5
HH-11 See page 56
Page 28
"Trade Price
$25.25 73.00 94.00 42.75 64.25
a
I
02428
^AMERICAN
^STANDARD
HYDRONiC HEATING
boiler-burner units
WATER AND STEAM
FR-A-5 fLAME RETENTION BOILER-BURNER UNITS
The FR-A-5 is a perfect combination of boiler and burner teamed for top performance. Develops 12V* COj. Tested and equipped for 50 lbs. water working pressure. Motors and controls regularly furnished are for 115 volt, 60 cycle power supply.
WATER
boiler-burner unit number
gross
1 =B = R output
Mbh
l=B=R burner capacity
gph
net
l=B=R rating Mbh
net rating sq. ft. water
Trade
Price with
standard equipment
For Built-in Water Heaters, Steam and Water Boilers, see page 28.
approx
shipping weight
chimney size
H
| 1
\
FRA-504-WB(T) FR-A-505-WB(T) FR-A-506-WB(T)
FR-A-507-WB(T) FR-A-508-WB(T) FR-A-509-WB(T)
FR-A-510-WB(T) FR-A-511-WB(T)
384 472 560
648 736 824
912 1000
3.55 4 30 5 10
5.90 6.70 7.45
8.25 9 05
333.9 410 4 487.0
563.5 640.0 716.5
793 0 869.6
2226 2736 3246
3756 4266 4776
5286 5797
$1025.00 1136.00 1325.00
1448.00 1602.00 1719.00
1843.00 1967.00
1576 1827 2110
2367 2626 2890
3144 3392
12 x 12 x 15 12 x 12 x 20 12 x 12 x 20
12 x 16 x 20 12 x 16 x 20 12 x 16 x 20
16 x 16 x 20 1 6 x 16x20
- = = |
STEAM
boiler-burner unit number
gross l=B R
output Mbh
1 =6 = R burner capacity
gph
net l = B = R rating
Mbh
sq. ft. steam
Trade Price with standard equipment
approx shipping
weight
chimney size
yHUI Hf GREW w
FR-A-504-SB(T) FR*A-505-SB(T) FR-A-506-SB(T)
FR-A-507-SB(T) FR-A-508-SB(T) FR-A-509-SB(Tj
FR-A-510-SB(T) FR-A-511-SB(T)
384 472 560
648 736 824
912 1000
3.55 4.30 5.10
5.90 6.70 7.45
8.25 9.05
288.1 354.1 420.1
486.1 552.1 618.2
684.2 750.2
1200 1475 1750
2025 2301 2576
2851 3126
$1025.00 1136.00 1325.00
1448.00 1602.00 1719.00
1843.00 1967.00
1577 1828 2112
2369 2628 2892
3147 3395
12 x 12 x 15 12 x 12 x 20 12 x 12 x 20
12 x 16 x 20 12 x 16 x 20 12 x 16 x 20
16 x 16 x 20 16 x 16 x 20
'Noz2ie sizes gph, furnished with the above units FR-A 504, 2 1 75 80 H; FR-A 505, 1 2 00 & 1 2.25 80 H, FR A 506, 1 4 00 70 S (200 Psig.) FR A 507, 1 4 50 70 S (200 Psig). FR A 508, 1 3 25 & 1 3 50 70 S; FR A 509, 1 3 50 & 1 4 00 70 S, FRA-510. 2 4 00 70 S, FR A 511. 2 4 50 70 S Suffm "T" denotes unit with openings m center sections for tankless heaters Start-up and one year service available Price on application.
Standard equipment
Flange mounted oil burner with 2-stage fuel unit; factory installed light sensing cad cell, bracket and leads; R8184G light sensing primary control. Delayed oil valve except on model 92A-7240-D and 92A-7242-D oil burners.
boiler-burner unit number
FR-A-504 FR-A-505 FR-A-506, FR-A-507 FR-A-508
oil burner
92A-7240-D 92A-7242-D 95A-300-7468-D (200 Psig fuel unit) 96A-M-7498-D
boiler-burner unit number
FR-A-509 FR A-510, FR-A-511
Draft regulator Drain valve
oil burner
96A-M-7546-B 96A-M-7548-B
Water: No. 3 control set: T822D thermostat
L4080B Aquastat limit control Nozzle(s)
ASME relief valve Pressure and temperature
gauge
Steam: No. 1 control set: T822D thermostat
PA404A Pressuretrol Nozzle (s)
ASME safety valve Steam gauge
Gauge glass with trimmings
Optional Equipment
Jacket extension: Jacket extension provides 25" enclosure in
front for concealment of oil burner and controls. Approxi
mate shipping weight 57 lbs. Specify on order. Added Trade
Price
$41.00
Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows:
Trade Price each
$4.00
For Factory Mutual Approval and Massachusetts code requirements, special electronic flame safeguard controls are available, with RA890 Protectorelay, W415A control panel (includes Q270A base and R488F switching relay),
C7013A photocell Delayed oil valve.
Control sets other than those included in Trade Price of FR-A-5 boiler-burner units will be furnished on order at the following added charges:
Control Set
added charge
Steam control set No. 2
$15-00
oil heating unit
FR-A-504 FR A 505 FR-A-506, FR-A-507 FR A-508 FR-A-509 FR-A 510, FR-A 511
burner model
92A-7240-L 92A 7242 L 95A-300 7468-L 96A-M-7498 L 96A M-7546 L 96A-M-7548 L
added Trade Price charge
Water control set No. 5 Water control set No 5-Z
22.00 27.75
$153.00
153.00 134.00 153.00 146.00 146.00
(Add-on zone Use only with No 5 Control Set The No 5 Z control set for circular zoning on units with tankless heaters )
Ordering Examples:
1 Boiler-burner unit with standard equipment 1 FR-A 506 SB oil heating unit 2 Boiler burner unit lor steam with optional equipment 1 FR A 509 SB T with No
control set. 3 No. 530 tankless heaters, 1 3 heater manifold
2
See page 56
Page 29
HH-11
02429
FLAME RETENTION BOILER-BURNER UNITS
WATER AND STEAM
^AMERICAN LSiSTANDARD
HYDRON1C HEATING
FR-A-7 FLAME RETENTION BOILER-BURNER UNITS
The perfect combination of boiler and burner teamed for top performance develop? l2K<fc C02. Available with or less jacket. Tested and equipped for 50 lbs. water working pressure. Operating controls furnished for 115 volt, 60 cycle pow'er supply.
WATER
boiler-burner unit number
FR-A-706-WO-B FR-A-707-WO-B FR A-708-WO-B
FR-A-709-WO-B FR-A-710-WO-B FR-A-711-WO-B
FR-A-712-WO-B FR-A-713-WO-B FR-A-714-WO-B
gross l = B= R output
Mbh
1160 1376 1580
1812 2020 2228
2440 2720 3000
l=B=R burner capacity
SPh
net
l=B=R
rating Mbh
A
piping 4 pick-up factor
10.55 12.30 14.15
16.35 18.15 20.20
21.95 24.10 26.30
1008.7 1196.5 1373.9
1575.7 1756.5 1937.4
2121.7 2365.2 2608.7
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
net
rating
tq. ft. water
unjacketed
Jacketed
Trade Price with standard
equipment
approx. Trade Price
shipping with standard
weight
equipment
approx. shipping
weight
chimney size
6724 7976 9159
10504 11710 12916
14144 15768 17391
$2242.00 2473.00 2938.00
3143.00 3467.00 3690.00
4248.00 4458.00 4768.00
4968 5626 6439
7223 7910 8558
9264 9950 10678
$2363.00 2611.00 3093.00
3410.00 3655.00 3894.00
4470.00 4697.00 5023.00
5144 5814 6750
7445 8149 8814
9534 10240 10988
16 x 16 X 30 16 x 20 x 35 16 x 20 x 35
20 x 20 x 40 20 x 20 x 45 20 x 20 x 55
20 x 24 x 60 20 x 24 x 70 24 x 24 x 80
STEAM
boiier-bumer unit number
FR-A-706-SO-B FR-A-707-SO-B FR-A-708SO-B
FR-A-709SO-B FR-A-710-SO-B FR-A-711-SO-B
FR-A-712-SO-B FR-A-713-SO-B FR-A-714-SO-B
gross
l-B-R output
Mbh
|=B=R burner capacity
gph
1160 1376 1580
1812 2020 2228
2440 , 2720 3000
10.55 12.30 14.15
16.35 18.15 20.20
21.95 24.10 26.30
net l=B== R rating
Mbh
sq. ft. steam
870.2 1041.6 1211.7
1403.6 1568.3 1729.8
1894.4 2111.8 2329.2
3626 4340 5049
5848 6535 7208
7893 8799 9705
piping & pick-up factor
unjacketed
Trade Price
with standard equipment
approx. shipping
weight
jacketed
Trede Price with standard equipment
approx. shipping
weight
chimney size
1.333 1.321 1.304
1.291 1.288 1.288
1.288 1.288 1.288
$2242.00 2473.00 2938.00
3143.00 3467.00 3690.00
4248.00 4458.00 4768.00
4970 5629 6441
7228 7915 8560
9266 9952 10680
$2363.00 2611.00 3093.00
3410.00 3655.00 3894.00
4470.00 4697.00 5023.00
5146 5817 6752
7450 8154 8816
9536 10242 10990
16x 16x 30 16 x 20 x 35 16 x 20 x 35
20 x 20 x 40 20 x 20 x 45 20 x 20 x 55
20 x 24 x 60 20 x 24 x 70 24 x 24 x 80
*American-Standard should be consulted before selecting an FR boiler-burner unit for installations having unusual piping and pick up requirements
'Nozzle sizes, gph, furnished with the above units: FR-A-706. I 5 00 4 1 5.50 80* S: FR-A-707, 2 6 00 80s S. FR A 708, 1 2 00 4 2 6 00 90 S: FR A 709. 1 3.00 4 2 6.50 90* S; FR-A-710, 2 9.00 70* $; FR-A-711. 2 10.00 70* S; FRA 712. 2 6 00 4 1 10.00 80fr S. FR A 713. 2 6 00 4 1 12 00 80:
S, FR-A-714 1 8 00 4 2 9 00 80* S
Start-up and one year service available. Price on application
Standard equipment:
Pedestal mounted oil burner with 2-stage fuel unit; on 96A-M-7543-B and 9708111-B burners, factory installed cad cell, bracket and leads: R8184B light sensing primary control. On 96A-T burners, RA890 Protectorelay and Q270A base, C7013A photocell; on 97A Hi-Lo and 98A Hi-Lo burners, R4150A Flame Safe guard control -- provides prepurge and postpurge, Q520A base, C7013A photocell. Delayed oil valve (2 with 96-A-T). Delayed and instantaneous valves with 97A Hi-Lo and 98A Hi-Lo.
boiier-bumer unit number
oil burner
standard motor voltage
FR-A-706, FR-A-707
FR-A-708 FR-A-709
FR-A-710, FR-A-711 FR-A-712, FR-A-713 FR-A-714
96A-M-7543 B
96A-T-7935-K 96A-T-7937-K
970-8111-B 97A Hi-Lo-7673 E 98A Hi-Lo-7773-E
115/60/1 115/60/1 115/60/1 115/60/1 230/60/1 230/60/1
12" cast iron base on all units. In addition, 8" high steel pedestal base is furnished with 8
through 14 section units.
Draft regulator.
Water: L4080B Aquastat limit control Steam: PA404A Pressuretiol
Nozzles ASME relief valve Pressure and temperature gauge Optional equipment: See page 33.
Nozzles ASME safety valve Steam gauge Gauge glass with trimmings
Combustion chamber not furnished. See lnstallation.Operetion and Maintenance Manual for combustion chambers required for FR-A-7 boiler-burner units.
N*e.' For Optional Electronic Flame Safeguard Control Equipment, See Page 33.
Ordering Examples:
1 Boiler-burner unit for steam jacketed with standard equipment 1 FR-A-710-SO-B boiler burner unit
2 Boiler-burner unit for water less jacket with optional equipment 1 FR;A-707-W0-B boiler burner unit with electronic flame safeguard controls to meet Factory Mutual Approval.
HH-11 See page 56
Page 30
02430
^AMERICAN C4 STANDARD
HYDRONIC HEATING
oil fired boilers WATER AND STEAM
A-5 OIL FIRED BOILERS
WATER
This boiler is designed for large residences, apartment and
commercial buildings. Tested and equipped for 50 lbs. water working pressure.
boiler number
gross l=B = R
output Mbh
t=B = R burner
capacity
iph
net
|s=B = R
rating
Mbh
net rating sq ft
water
Trade Price
approx. shipping
weight
For Built-in Water Heaters, Steam and Water Boilers, see page 28.
A-504-WCT) A-505-W(T) A-506-W(T)
A-507-W(T) A-508-WCTj A-509W(T)
A-510-W(T) A-511-W(Tj
261 2.55 227.0 1513 $ 744.00
346 3.30 300.9 2006
855.00
426 4.00 370.4 2469
974.00
508 4.75 441.7 2944 588 5.55 511.3 3408 668 6.30 580.9 3872
1097.00 1215.00 1332.00
748 7.00 650.4 4336 830 7.65 721.7 4811
1455.00 1580.00
1518 1770 2025
2282 2539 2794
3050 3298
chimney size
8 x 12 x 15 8x 12 x20 12 x 12 x 20 12 x 12 x 20 12 x 16 x 25 12 x 16 x 25 12 x 16 X 25 16 x 16x30
STEAM
boiler number
A-504-S(T) A-505-SCO A-506-S(T) A-507-SCT) A-508-S(Tj -- A-509-S(T)
A-510-SCT) A-511-S(T)
gross IsBsR output
Mbh
261 346 426
508 588 668
748 830
l = B=R burner capacity
gph
2.55 3.30 4.00
4.75 5.55 6.30
7.00 7.65
net l = B= R rating
Mbh
sq ft steam
195.8 259.6 319.6
381.1 441.1 501.1
561.1 622.7
816 1082 1332
1588 1838 2088
2338 2594
Trade Price
$ 744.00 855.00 974.00
1097.00 1215.00 1332.00
1455.00 1580.00
approx. shipping
weight
1519 1771 2027
2284 2541 2796
3052 3300
chimney size
8 x 12 x15 8 x 12 x 20 12 x 12 X 20
12 x 12 x 20 12 x 16x25 12x16x25
12 x 16 x 25 16 x 16x30
Suffix "T" denotes boiler with openings in center sections for tankless heaters.
Standard equipment:
Optional equipment:
Water: ASME relief valve Pressure and temperature gauge Drain valve
Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows:
Trade Price each
$4.00
Steam: ASME safety valve Steam gauge
Zone valve packages are available for water boilers. For details and prices, see page 34.
Gauge glass with trimmings Drain valve
Oil Burners available on special order............................................. Price on Application
Ordering Examples:
1. Boiler only for steam with standard equipment: 1 A-507-S boiler.
2. Boiler only for water with optional equipment: 1 A-506-W boiler with jacket extension
Jacket extension: Specify on order and add $41.50 to Trade Price of boiler or unit. Jacket extension provides 25" en closure in front for concealment of oil burner and controls. Approximate shipping weight 57 lbs.
A-5 OPTIONAL EQUIPMENT HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit number
A-504 A-505 A-506 A-507, A-508 A-509, A-510, A-511
Heat Llb-O-Rator model No. included
14A 15A 15-AA 16-A 17-A
maximum firing rate gallons per hour
2.55 3.30 4.00 5.55 7.65
Trade Price
$38.00 $38.00
47.00 47.00 55.00
approx. shipping weight
158 163 176 180 200
See page 56
Page 31
HH-11
OIL FIRED BOILERS
WATER AND STEAM
AMERICAN kSJ STANDARD
HYDRONIC HEATING
A-7 OIL FIRED BOILERS
Ideal for commercial and industrial buildings. Available with or less jacket. Tested and equipped for 60 lbs. water working pressure.
WATER
boiler number
gross l=B=R
output Mbh
l =B=R
burner capacity
gph
net
l=B=R
rating Mbh
A
piping & pick-up factor
net rating sq. ft. water
unjacketed
w approx. Trade Price shipping
weight
jacketed
Trade Price
approx. Shipping
weight
chimney size
A-705-WO A-706-WO A-707-WO
A-708-WO A-709-WO A-710W0
A-711-WO A-712-WO
A-713-WO A-714-WO
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
21.45 23.20
753.0 880.0 1040.0
1196.5 1365.2 1530.4
1700.9 1867.8
2034.8 2201.7
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15
1.15 1.15
5020 5866 6933
7978 9101 10202
11339 12452
13565 14678
(1723.00 1879.00 2112.00
2334.00 2539.00 2752.00
2974.00 3155.00
3343.00 3559.00
4186 4787 5445
6029 6669 7330
7956 8616
9278 9944
(1827.00 2001.00 2249.00
2489.00 2710.00 2939.00
3179.00 3376.00
3603.00 3812.00
4358 16 x 16 x 28 4963 16 x 16 x 30 5633 16 x 20 x 36
6240 16 x 20 x 42 6891 16 x 20 x 45 7569 20 x 20 x 50
8212 20 x 20 x 55 8886 20 x 20 x 60
9568 20 x 24 x 70 10254 20 x 24 x 80
STEAM
boiler number
A-705-S0 A-706-SO A-707-50
A-708-SO A-709-SO A-710S0
A-711-SO A-712SO
A-713SO A-714-SO
gross l=B=R
output Mbh
l=B=R burner capacity
gph
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
21.45 23.20
net 1 = B=R rati ng
unjacketed
Mbh
sq ft steam
A
piping & pick-up
Trade
Price
factor
approx. shipping
weight
jacketed
w Trade Price
approx. shipping weight
chimney size
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
1816.8 1965.8
2707 3163 3738
4340 5013 5672
6328 6949
7570 8191
1.333 1.333 1.333
1.321 1.305 1.293
1.288 1.288
1.288 1.288
(1723.00 1879.00 2112.00
2334.00 2539.00 2752.00
2974.00 3155.00
3343.00 3559.00
4187 4788 5447
6030 6673 7334
7957 8617
9279 9945
(1827.00 2001.00 2249.00
2489.00 2710.00 2939.00
3179.00 3376.00
3603.00 3812.00
4359 16 x 16 x 28 4964 16 x 16 x 30 5635 16x20x36
6241 16 x 20 x 42 6895 16 x 20 x 45 7573 20 x 20 x 50
8213 20 x 20 x 55 8887 20 x 20 x 60
9569 20 x 24 x 70 10255 20 x 24 x 80
* The net l = B=R ratings shown are based on piping and pick-up allowances listed in the column next to the ratings American Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements
Standard equipment:
Water: ASME relief valve
Pressure and temperature gauge
Steam: ASME safety valve Steam gauge Gauge glass with trimmings
Optional Equipment:
Steel pedestal bases for installation under the regularly furnished 12 inch cast iron base for greater base heights are available on order at the fol lowing added charges:
lection tire
bon height
strode Price
5 thru 7 8 thru 14
8" 10'
$59.00 96.00
If steel pedestal base is not used, consideration should be given to the use of brick or masonry base as required.
For Additional Optional Equipment, See page 33.
Combustion chamber not furnished. See Installation-Operation and Maintenance Manual far combustion chambers required far A-7 boilers.
Ordering Examples: 1. Boiler only with jacket for steam with optional equipment 1 A 711 SO boiler jacketed with steel pedestal base
2. Boiler only unjacketed for water with standard equipment 1 A-706-WO unjacketed
Note: Be sure to specify on order letter "0" after fired boiler will be supplied
or "W" or coal
HH-11 See page 56
Page 32
02432
AMERICAN STANDARD
HYDRONIC HEATING
on burners
OPTIONAL EQUIPMENT
A-7 AND FR-A-7 OPTIONAL EQUIPMENT
ELECTRONIC FLAME SAFEGUARD CONTROL EQUIPMENT
For Factory Mutual Approval requirements, special electronic flame safeguard controls are available with RA890 Protectorelay, W415A control panel (includes Q270A base and R488F switching relay),C7013A photocell.
Delayed oil valve. (2 with 96A-T-7935-R and 96A-T-7937-R.)
Oil burners to meet Massachusetts Code requirements -- Price on application.
boiler-burner unit
FR-A-706, FR-A-707 FR-A-708 FR-A-709 FR-A-710, FR-A-711
burner model
96A-M-7543-L 96A-T-7935-R 96A-T-7937-R 970-8111-R
added Trade Price charge
$139.00 46.00 46.00
139.00
NOTE: R4150A Flame Safeguard control on 97A Hi-Lo and 98A Hl-Lo burners used with FR-A-712, FR-A-713 and FR-A-714 units meets Factory Mutual Approval and Massachusetts code requirements.
McDonnell &. Miller low water cut-off and feeder combinations or low water cut-offs are
available for FR-A-7 and A-7 steam units and boilers at added Trade Prices as follows:
unit or boiler no.
M&M no.
Added Trade Price
FR-A-706. A-705 thru A-707 FR-A-707 thru FR-A-713 A-708 thru A-714 FR-A-714
A-7 and FR-A-7
47-2
51-2 51-S-2
369
$ 72.70
93.90 106.00
25.23
Provision for special equalizer tapping (1" I.P.S. maximum) for bottom connection of 51 -2 or 51-S-2 is located 12V* inches below water line on front section.
Other temperature controls are shown on page 36.
FR-A-7 and A-7 external water heater tappings: two 1" tappings will be furnished on center sections for water boilers only. Lower tapping 23" from bottom of section. Center to center dimension between tappings is 21W. If desired specify on order and add $11.75 per "C" section to Trade Price of boiler.
DfcUOIL BURNERS
The DH burner is designed and built to exacting standards for dependable and trouble free operation. The quiet motor and reliable controls are regularly furnished for 115 volt, 60 cycle power supply.
model number
DH-5 DH-8 DH-15 DH-23
capacity qal.
per hour
.55 3.00 .65 - 3.00 ,65 - 3.00 .65 - 3.00
air tube diem. length
mounting
Trode Price with noxzle
includes factory installed cad cell
with no. 1 or no. 3 central set and primary control
with primary central end
nozzle
less cod ceil
45
sling
4 8 / pedestalT
4 15 < r > 4 23 l flange )
$155.00
155.00 157.00
159.00
$137.00 139.00 141.00
$105.00 109.00
111.00
app. ship, weight
with control
set
55 60 64 68
boiler-bumer unit oil burner controls
AP(T)
BDH-5
A-3 packaped unit DH-5
{Primary control, cad cell and ) controls, except thermostat,
) factory installed. [ Draft regulator.
A-3 boiler unit
DH-5
/Primary control, controls. < Cad cell factory installed. (.Draft regulator.
Note: For A-3 units pressure ring is packed with DH-5 burner.
DH-5 burners for AP(T) packaged units furnished with refractory turbulator and are not interchangeable with other DH-5 models.
Nozzles with Strainers for OH burners used with boiler-burner units:
Solid cone 60 with AP(T), solid cone 70 with A-3 pack aged or boiler-burner units.
Oil burners listed in this Price Book are approved by the National Board of Fire Underwriters, comply with U. S. Government Commercial Standard CS-75, and are for use with No. 1 or No. 2 fueloil.
Capacities of oil burners using No. 1 or No. 2 fueloil are for
installations at sea level and at elevations up to 1,000 feet. Reduce by 4% for each additional 1,000 feet above sea level.
Deduct from shipping weight of burner with control set:
less control set
3 lbs.
less control set and primary control
9 lbs.
Disc-turbulator combina
tions for DH oil burner are as follows:
Selection of nozzle:
firing rate
no. gph
firing rate
gph
nozzle
pray
R1
.55-1.10
.55 to 1.25 60* -70* hollow
R2 1.00-1.85
1 .65-1.10
or solid
2
.90-1.75
above 1.25 60'-70* solid
3 1.80 2.50
4 2.35-3.00
The correct disc-turbulator combination is furnished in stalled in the DH burner for nozzle size specified on order.
Two-stage fuel unit is available for DH oil burners at added
Trade Price
$6.15
Controls and control sets are shown on page 35.
Ordering Examples: 1 Oil Burner 1 DH-5 oil burner with No. 5 control set and 2.50 gph 70 solid nozzle for A-37M-WBT boiler-burner unit. 2. Oil Burner 1 DH-23 oil burner with No. 3 control set, 1.50 gph 60 solid nozzle, with pedestal.
See page 56
Page 33
HH-11
02433
ZONE VALVE PACKAGE COMfORT COMPUTER
Illustrated is Comfort Computer-Zone
Valve Package
AMERICAN a STANDARD
HYDRONIC HEATING
COMFORT COMPUTER MODEL 370(R)
The American Standard exclusive and unique Comfort Computer is a solid state control which modulates the boiler water temperature in proportion to the number and length of heat demands. This control and zone valve pack age is especially designed for use with American Standard Boilers. Bene fits received are: improved comfort balance in living areas; reduction of wall streaking and expansion noises; and increased operating efficiency.
The Comfort Computer controls the operation of the burner to slow down the response of the boiler temperature to calls for heat by a zone thermo stat. The control optimizes boiler water temperature and will not permit introduction of excessively hot water temperature to a zone. This control permits only those boiler water temperatures actually required by the heating system, yet permits high water temperatures during cold weather or during "pick-up" periods.
The Comfort Computer is designed for Gas Boilers without tankless heaters; and is available in two models, the 370 and the 370R. The model 370 is for use with installed boilers using a solenoid gas valve only; the 370R is for use with all modern gas fired hydronic heating systems.
''Trade Prices are as follows: 370 ........................ $40.00
370R........................ $51.00
COMFORT COMPUTER - ZONE VALVE PACKAGE
The Comfort Computer is available combined with the zone valve package factory mounted and
wired. When ordering the complete package the
designation of the zone valve package is added to that of the Comfort Computer,
"Trade Prices are: 370R-2Z--$132.50 370R-3Z- $159.00 370R-4Z- $199.00
HYDRONIC ZONE VALVE PACKAGES
No. Z*2 Package for 2 Zones
No. Z-3 Package for 3 Zones
No. Z-4 Package for 4 Zones
1 T822D thermostat
2 V8043F 44" zone valves soldered to
manifold Less transformer Trade Price................................$82.00
2 T822D thermostats
3 T822D thermostats
3 V8043F 44" zone valves soldered to 4 V8043F 44 " zone valves soldered to
manifold
manifold
Less transformer
With transformer
Trade Price ............................... $108.00 Trade Price..................
$148.00
Each zone valve package consists of 2, 3, or 4 Honeywell 44" zone valves soldered to manifold with 1J4" NPT inlet. Each zone valve is factory wired to low voltage leads for transformer and all end (auxiliary) switches are wired in parallel with a pre-wired harness. On-the-job wiring re
quires 115 volt line to transformer, low voltage connections to circulator control, and low voltage wiring to each
thermostat.
If Vfe" system piping is used, a % x Vfe nominal copper to copper flush bushing can be soldered to any or all of the 44 " zone valves on the manifold. Flush bushing not furnished.
One less thermostat is furnished than the number of zone valves per package. An additional thermostat is required when zone valve package is used on boiler furnished less thermostat.
40 VA transformer is not required when control L8148G or R8226B with power for 3 zone valves, is supplied with boiler.
If 40 VA transformer is wanted with No. Z-2 or No. Z-3 Packages, specify on order and add to the above Zone Valve Pack
age prices..............................................
..................
. Trade Price each $3.10
Honeywell V8043F 4 " Zone Valve sold separately
HH-11 ^ See page 56
Page 34
....
. . T Trade Price each $21.75
02434
fSl AMERICAN IS STANDARD
HYDRONIC HEATING
CONTROL SETS, CONTROLS
CONTROL SETS FOR BOILER-BURNER UNITS
Control tet
no. 1 steam
no. 2 steam
for boiler without domestic hot water
boiler with year-round domestic hot water, tankless heater
no. 3 gravity water
no. 4 forced water
boiler without domestic hot water, immersion control
boiler without domestic hot water
no. 5
A-3, A-5, FR-A-5 units only with year-round
forced water domestic hot water
no. 5-Z forced water
A-3, A-5, FR-A-5 units only. (1 no. 5-Z set is required for each zone in addition to the first zone which is controlled by the no. 5 control set or equivalent.)
control number
T822D PA404A
T822D PA404A L4006A
T822D L4080B
T822D L4081B
T822D L8124C
T822D R845A
contents of control set
description
Thermostat Pressuretrol
Thermostat Pressuretrol Aquastat operating control
Thermostat Aquastat limit control
Thermostat Aquastat limit and circulator control
Thermostat Aquastat limit, reverse and operating control, circulator relay
Thermostat Relay
add to Trade Price of oil burner with basic control set
$14.05
$11.00 $22.40 $26.20
number T822D
TS822A T832A
description
thermostat, adjustable heater 0.18 to 0.8 amp. thermostat, millivolt thermostat, low voltage, manual
T852A L4006A L4006E
L4081B L4080D L4080B L6O06A
L8124C
Aquastat operating control Aquastat operating control; locks out on high limit setting; manual reset
Aquastat limit and circulator control Aquastat limit control Aquastat limit control Aquastat operating and circulator
Aquastat limit, reverse and operating control, circulator relay: line voltage burner control, horizontal
L8124B L8124E
L404C L604A L8148E L8048G
millivolt burner circuit for gas with manuai-auto switch, vertical case
low voltage burner circuit for gas, vertical case. Power for 2 zone valves
Aquastat-relay combination, high limit and line voltage circulator control. horizontal case:
Pressuretrol w/man. reset
SPDT operating controller
low voltage burner control for gas. Power for 2 zone valves.
millivolt burner control for gas. Power for 3 zone valves.
CONTROLS
Trade Price
number
$ 6.B5 6.85
25.30 40.10 14.05
PA404A RA89A RA832A R845A
R8226B R8182D
16.15 20.90 10.60 10.60
14.90
R8182E R8182F
39 3fl
29.40
31.80
R8184G
28.20 25.40
22.35
120320
description
Trade Price
Pressuretrol relay, SPST relay, DPST relay, DPST
Transformer and circulator relay
Aquastat-relay combination, high and low limit; providing room thermostat control of circulator; light sensing primary control, less cad cell; safety switch timing 70 seconds. For use with tankless.
Aquastat combination, high limit; providing room thermostat control of circulator: light sensing primary control, less cad cell; safety switch timing 70 seconds. For use less tankless.
Aquastat combination, high limit; providing room thermostat control of burner and boiler water temperature control of circulator; light sensing primary control, less cad cell; safety switch timing 70 seconds. For use less tankless.
light sensing primary control, less cad cell:
control number
safety-switch timing-seconds gph
R8184G1005
60
R8184G1021
30
R8184G1013
15
cadmium sulfide cell only
3 3-7 7-20
$16.10 15.35 19.35 19.35 10.60
54.50
50.00
44.60
30.00 32.95 36.80
2.20
22.35
See page 56
Accessories and controls included In this price book are for use in coniunction with American-Standard products
Page 35
HH-11
02435
STOKER FIRED BOILERS
WATER ANO STEAM
^AMERICAN IS STANDARD
HYDRONIC HEATING
A-7 STOKER FIRED BOILERS
The standard for commercial and industrial building application. Available with or less jacket. Tested and equipped for 50 lbs. water working pressure
WATER
bolter number
A-705-WC A-706-WC A-707-WC A-708-WC A-709-WC A-710-WC A-711-WC A-712-WC A-713-WC A-714-WC
gross l=B=R output
Mbh
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
l=B=R burner capacity lbs./hr.
95 111 131
151 172 194
215 236
257 278
* net l = B-R
rating Mbh
753.0 880.0 1040.0
1196.5 1365.2 1530.4
1700.9 1867.8
2034.8 2201.7
a
piping & pick-up factor
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15
1.15 1.15
net rating sq. ft. water
5020 5866 6933
7978 9101 10202
11339 12452
13565 14678
unjacketed
lacketed
Trade Price
approx.
shipping weight
Trade Price
approx. shipping
weight
$1723.00 1879.00
2112.00
2334.00 2539.00 2752.00
2974.00 3155.00
3364.00 3557.00
4120 4775 5436
6017 6693 7370
7972 8610
9323 10013
$1827.00
2001.00
2249.00
2489.00 2710.00 2939.00
3179.00 3376.00
3603.00 3812.00
4292 4950 5619
6226 6908 7589
8233 8908
9593 10283
chimney
size
16 x 16 x 28 16 x 16 x 30 16x20x36 16 x 20 x 42 16 x 20 x 45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60
20 x 24 x 70 20 x 24 x 80
STEAM
boiler number
A-705-SC A-706-SC A-707-SC A-708-SC A-709-SC A-710-SC A-711SC A-712-SC A-713-SC A-714-SC
gross |=B=R output
Mbh
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
l = B=R burner capacity lbs./hr.
-95 111 131
151 172 194
215 236
257 278
net l = B = R rating
Mbh
sq. ft. steam
*
piping & pick-up factor
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
1816.8 1965.8
2707 3163 3738
4340 5013 5672
6328 6949
7570 8191
1.333 1.333 1.333
1.321 1.305 1.293
1.288 1.288
1.288 1.288
unjacketed
Trade Price
approx.
shipping weight
jacketed
Trade Price
approx. shipping
weight
chimney size
$1723.00 1879.00 2112.00
2334.00 2539.00 2752.00
2974.00 3155.00
3364.00 3557.00
4121 4776 5438
6018 6697 7374
7973 8611
9324 10014
$1827.00 2001.00 2249.00
2489.00 2710.00 2939.00
3179.00 3376.00
3603.00 3812.00
4293 4951 5621
6227 6912 7593
8234 8909
9594 10284
16 x 16 x 28 16 x 16x30 16 x 20 x 36
16 x 20 x 42 16x20x45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60
20 x 24 x 70 20 x 24 x 80
* The net f=r8 = R ratings shown are bated on piping and pick-up allowances listed in the column next to the ratings. American-Standard should be consulted before selecting a boiler for instolfations having unusual piping and pick-up requirements.
Standard equipment:
Water: ASME relief valve Pressure and temperature gauge
Steam: ASME safety valve Steam gauge Gauge glass with trimmings
Optional equipment:
Steel pedestal bases for installation under the regularly furnished 12 inch cast iron base for greater base heights are available on order at the following added charges:
section size
5 thru 7 8 thru 14
base height
8" 10"
Trade Price
$59.00 96.00
If steel pedestal base is not used, consideration should be given to the use of brick or masonry base as required.
For additional optional equipment see page 33.
Ordering Example: Stoker boiler for water with jacket with optional equipment 1 A-708-WC jacketed boiler, with $teel pedestal base.
HH-11 See page 56
Page 36
02436
rS1 AMERICAN ksSTANDARD
HYDRONIC HEATING
A-7 HAND FIRED BOILERS
Jacketed and unjacketed Tested and equipped for BO lbs. water working pressure
hand fired boilers WATER AND STEAM
WATER
boiler number
A-705-W A-706-W A-707-W A-708-W A-709-W A-710-W A-711-W A-712-W
gross l= B=R output
Mbh
1122 1298 1510
1708 1910 2108
2288 2456
net l = B=R
rating Mbh
A
piping & pick-up factor
1
net rating sq. ft. water
625.4 744.3 894.0
1042.1 1202.0 1363.5
1518.2 1667.3
1.794 1.744 1.689
1.639 1.589 1.546
1.507 1.473
4169 4962 5960
6947 8013 9090
10122 11115
un|acketed
"W Trade Price
approx.
shipping weight
$1897.00 2064.00 2296.00
2533.00 2709.00 2895.00
3117.00 3280.00
4546 5270 6025
6679 7508 8170
8848 9565
jacketed
Trade Price
approx.
shipping weight
$2002.00 2185.00 2434.00
2688.00 2880.00 3084.00
3322.00 3501.00
4718 5545 6208
6888 7643 8389
9109 9863
chimney size
16 x 16x40 16 x 20 x 45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60 20 x 24 x 65
20 x 24 x 70 24 x 24 x 75
STEAM
boiler number
A-705-S A-706-S A-707-S A-708-S A-709-S A-710-S A-711-S A-712-S
gross l=B=R output
Mbh
1122 1298 1510
1708 1910 2108
2288 2456
net l = B=R
Mbh -
sq. ft. steam
A
piping & pick-up factor
625.4 744.3 894.0
1042.1 1202.0 1363.5
1518.2 1667.3
2606 3101 3725
4342 5008 5681
6326 6947
1.794 1.744 1.689
1.639 1.589 1.546
1.507 1.473
unjacketed
Trade Price
approx. shipping
weight
$1897.00 2064.00 2296.00
2533.00 2709.00 2895.00
3117.00 3280.00
4561 5285 6036
6692 7521 8183
8861 9582
jacketed
Trade Price
approx.
shipping weight
$2002.00 2185.00 2434.00
2688.00 2880.00 3084.00
3322.00 3501.00
4733 5460 6219
6901 7656 8402
9122 9880
chimney size
16 x 16x40 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 65 20 x 24 x 70 24 x 24 x 75
AThe net l=B=R ratings shown are based on piping and pick up allowances listed in the column next to the ratings. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick up requirements.
Standard equipment:
Water: ASME relief valve Pressure and temperature gauge Automatic damper regulator Firing tools
Steam: ASME safety valve Steam gauge Gauge glass with trimmings Automatic damper regulator Firing tools
Ordering Example:
Hand fired boiler for water with jacket with standard equipment: 1 A-706-W jacketed boiler
See page 56
Page 37
HH-11
02437
HYDRONIC ASSEMBLING TOOLS
^AMERICAN kS STANDARD
HYDRONIC HEATING
PACKAGED HYDRAULIC ASSEMBLING TOOL: All necessary parts to assemble any American-Standard sectional boiler, except long tie rods, are shipped in one packing case; the long tie rods are furnished in their own wooden box. Total weight approximately 250 lbs.
W Trade Price - $400.00
RADIANTRIM ASSEMBLY CLAMP. This tool is designed to draw Radiantrim cast iron baseboard sub-assembled panels or sections together with ease as per instructions included. Order through your American-Standard distributor.
Trade Price each - $10.75
HEATRIM COPPER TUBE BENDING TOOL: This tool is specifically designed to bend riser tube connections for Model R Heatrim baseboard panels. Eliminates costly copper fittings. Com plete instructions for tool use included.
Trade Price each -- $14.55
HEATRIM RISER HOLE TEMPLATE:
This tool accurately and quickly lo cates riser hole locations for Model R Heatrim panels. Consists of template (two pieces), 8 ft. steel tape and com plete instructions.
Trade Price each -- $2.90
ALUMINUM NIPPLE SETTING-HAMMER:
--consists of a 2 )b. 2V6" diameter aluminum head and a 14" long hard wood handle. The aluminum head will not damage the nipple edges and per mits the heavy blows necessary to set nipples to the recommended depth quickly.
Trade Price each -- $4.75
SECTION BUMPING BLOCK: -- made of a G" x G''x 18" hardwood block with a convenient steel handle for swinging the tool. Its purpose is to bump a sec tion onto the pre-set nipples of the previous section to the recommended depth, prior to pulling the section up. with one or two blows without damage to the section.
Trade Price each -- $14.00
HH-11 'W See page 56
Page 38
02438
AMERICAN bd STANDARD
HYDRONIC HEATING
ELECTRA II PACKAGED ElECTRO-HYDRONIC BOILERS
Completely packaged with deluxe two-toned brown and beige jacket. l'ie-wired for 240 volt, three wire, 60 cycle, single phase service. Designed and equipped with controls for forced circulation.. Tested and equipped for 30 lbs. water working pressure.
PACKAGED BOILERS ELECTRIC WATER
'.tfLrItSTTa4 E&Dor
ELECTRIC CENTRAL MCATING BOILER WITH IHTESRAL LIMIT CONTROL
E38076
NO 0000000
WATER ONLY
packaged unit
number
EP-7
EP-10
EP-14
EP-17
EP-20
output watts
2,000 3,000 4,000 5,000 ~ 6,000
output
btuh
6,826
10,236
13,648 17,060
20,472
amps 240 volts
8.34 12.50 16.65 20.81 25.00
Trade Price with
standard equipment
$193.00
193.00
193.00
193.00
193.00
approx. shipping
weight
49
49
49
49
49
Ordering Example:
EP Packaged Boiler with standard equipment:
1 EP'14 boiler
Standard equipment
T822D thermostat Circulator with piping Drain valve ASME relief valve Pressure and temperature gauge Expansion tank (diaphragm type) L4080D immersion limit control J. W. Hobbs M4440 low pressure switch Automatic air vent Output ratings based on 240 volts. Reduce output ratings for other
voltages as follows: 230 volts, 8%; 220 volts, 16%; 208 volts, 25%.
All electrical controls, circulator, expansion tank, pressure and tempera ture gauge, automatic air vent, and drain valve, are factory installed and wired. Thermostat and relief valve shipped in accessory bag fastened inside boiler carton.
Zone valve packages are available for water boilers. For details and Prlces. see PaSe 34
See page 56
Page 39
HH-11
02439
PACKAGED BOILERS ELECTRIC WATER
^AMERICAN La STANDARD
HYDRONIC HEATING
"ELECTRA"
EP PACKAGED ELECTRO-HYDRONIC BOILER
For the ultimate in modern electric heating, choose the "Electra.'' a completely assembled pre-wired, hydromc heating cast iron boiler
Designed for ultra-safe operation and equipped with controls for forced circulation.
Attractive two-toned brown and beige jacket completely conceals all components including the circulating pump and expansion tank
Rugged boiler shell is tested and equipped for 30 lbs water working pressure and unit is ar ranged for 240 volt, three wire. 60 cycle, single phase service
WATER
packaged
boiler
number
number of
elements
output watts
output btuh
amps <s>
240 VOltS
EP-34
2
10,000
34,130
41.7
EP-51 3 15.000 51,195
62.4
EP-68 4 20,000 68,260
83.2
EP-82
5
24.000
81.912
100.0
ELECTRIC CENTRAL HEATING 600.
WITH '"ECRAL limit control
118076
No <*, ,
'Trade Price with
standard
equipment
$387.00 400.00 416.00 431.00
approx. 1 chipping --4| weight %
98 99 100 102
Standard equipment T822D thermostat AT72D low voltage transformer R8154 sequencing control L4008J adjustable immersion type limit control Allen-Bradiey 836CP11-HKAZS High pressure switch with EP-68 and]
EP-82 only J. W. Hobbs M4440 Low pressure switch iy4" circulator Expansion tank (diaphragm type) Automatic air vent ASME Relief valve Pressure and temperature gauge Drain valve
Ordering Example: EP Packaged Boiler with standard equipment 1 EP-68 boiler
HH-11 See page 56
Note: EP Electric Boilers are shipped with jacket and all controls (except thermostat and relief valve) factory installed and wired. Circulator and expan* ! sion tank are factory installed and enclosed in the jacket. Thermostat, relief valve and nipple, and circulator flange and gasket shipped in accessory bag ^ fastened inside boiler carton.
Output ratings based on 240 voltss>,. Reduce output ratings for other voltages as follows: 230 volts, 89 ; 220 volts, 16%; 208 volts, 25%.
Optional equipment
Sequencer Package: Available for field installation on EP-68 and EP-82 i Boilers in addition to regularly furnished sequencing relay. Package contaM* j all necessary equipment and instructions for the installation of one or two (EP-82) 24A11-4 Sequencers) which will provide a 45 second currJr**J delay between the third and fourth elements of the EP-68 or between third, fourth and fifth elements of the EP-82 Standard R8154 relay provide*^ a 1/120th of a second (^ cycle) current delay between each element.
Sequencer Package
Trade Price
EP-68
$11.13
EP-82
21.47
Note: Zone valve packages are available for water boilers. For details *8*^
prices, see page 34.
Page 40
02440
^AMERICAN IS STANDARD
HYDRONIC HEATING
HEATRIM PANELS
MODEL R HEATRIM PANELS
SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS
(For
Model R-750A and >/2" Model R-500-A Panels)
For comparative and estimating purposes only.
DESCRIPTION
ordering number
packaged per
MODEL R-750-A COMPLETE ASSEMBLED
R-750A2
UNITS (Single Pack) Packed in a "pull tape" box,
R-750-A3
includes 1 each of front and
R-750-A4
back panel, element.
damper, necessary support
R-750A5
brackets, slide cradles and 1 set joining pieces. Finished with
R-750 A6
white prime paint. All factory R-750-A7 assembled.
Box Color Coded--Red
R-750-A8
Ordering Example:
1-box R-750-A4
per lineal foot
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
Trade Price
approx.
shipping weight
$ 2.09
4.18 6.2? 8.36 10.45 12.54 14.63 16.72
5 7 9 12 13 16 18
MODEL R-500-A COMPLETE ASSEMBLED UNITS (Single Pack)
Packed in a "pull tape" box, includes 1 each of front and back panel, element. damper, necessary support brackets, slide cradles and 1 set joining pieces. Finished with white prime paint. All factory assembled.
Box Color Coded-Green
Ordering Example:
1--box R-500-A3
R-500-A2 R-500-A3 R-500A4 R-500-A5 R-500-A6 R-500A7 R-500A8
per lineal foot 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
1.98 3.97 5.95 7.94 9.92 11.91 13.89 15.88
5 7 9 11 14 15 18
MODEL R ENCLOSURE ONLYASSEMBLED (Single Pack)
Packed in a "pull tape" box, includes 1 each of front and back panel, damper, necessary support brackets, slide cradles and 1 set joining pieces. Finished with white prime paint. All factory assembled.
Box Color Coded--Black
Ordering Example:
1-box R-3-A
R-3-A R-4-A R-5-A R-6-A R-7-A R-8-A R-10-A R-12-A
per lineal foot
3 ft. length 4 ft. length 5 ft- length 6 ft. length 7 ft. length 8 ft. length 10 ft. length 12 ft. length
1.02
3.06 4.07 5.09 6.11 7.13 8. IS 10.19 12.22
6 8 10 11 13 15 17 19
MODEL R ENCLOSURES ONLYUNASSEMBLED (Bulk Pack)
Packed in a "pull tape" box, includes 3 sets of front and back panels, dampers with clips, necessary support brackets, slide cradles and 2 sets of joining pieces. Finished with white prime paint. Unassembled.
Box Color Coded--Blue
Ordering Example:
1-box R-5-B
R-3-B R-4-B R-5-B R-6-B R-7-B R-8-B R-10-B R-12B
per lineal foot
three 3' lengths three 4' lengths three 5' lengths three 6' lengths three T lengths three 8' lengths three 10' lengths three 12' lengths
.91
8.22 10.96 13.70 16.44 19.18 21.92 27.41 32.89
16 21 26 30 35 40 48 58
See page 56
Page 41
HH-11
02441
aa Is M 1= aS. Io> o c3
02442
1.59 1.63
rH rH rH H r1* rH
.222.
02443
Net P rice
HEATRIM ELEMENTS AND ACCESSORIES
IAMERICAN kSiSTANDARD
HYDRONIC HEATING
MODEL R HEATRIM ELEMENTS AND ACCESSORIES
l nriii|ininm --
DESCRIPTION
E-750 (V tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths Ordering Example:
1--bundle E-750-3
ordering number
E-750-3 E-750-4 E 750 5 E-750-6 E-750-7 -750-8
packaged per
per lineal foot
Trade Price I 1.12
approx. shipping weight
six 3' lengths six 4' lengths six 5' lengths six 6' lengths six 7' lengths six 8' lengths
20.22 26.96 33.71 40.45 47.19 53.93
9 12 16 18 22 25
E-5O0 W tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths.
Ordering Example: 1-bundle E-500-4
E-500-3 E-500-4 E-500-5 E-500-6 E-500-7 E-500-8
*per lineal foot $ 1.02
six 3' lengths six 4' lengths six 5' lengths six 6' lengths six T lengths six 8' lengths
18.33 24.44 30.56 36.67 42.78 4B.89
8 10 12 16 19 21
ACCESSORIES
End Cap-3" wide-Right Hand End Cap-3" wide-Left Hand Valve Enclosure--I" wide--Right Hand Valve Enclosure-4" wide--Left Hand Valve EncJosure-6" wide--Right Hand Valve Enclosure--6" wide--Left Hand Inside Cornor-hinged front and top--90 Inside Corner-back piece--90 Inside Cornor-one-piece front and top-1350 /45c Inside Corner-back piece-1350/450 Outside Corner-90-' Outside Corner-I35V45 Filler piece set-7" wide Filler piece set-14" wide Wall End Pieoe-3" wide Return tubing wire bangers Connecting tubing wire hangers Joining piece set--" wide Extra support brackets with slide cradles and damper
clips Tube bending tool
NOTE: Finished with white prime paint.
RA-ECR-03 RA-ECL-03 RA-VER-04 RA-VEL-04 RA-VER-06 RA-VEL-06 RA-ICF-90 RA-ICB-90 RA-ICF-45 RA-ICB-45 RA-OCF-90 RA-OCF-45 RA-FPS-07 RA-FPS-14 RA-WEP-03 RA-WHR-50 RA-WHS-50 RA-JPS-02
box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 5 box of 10 bag of 50 bag of 50 box of 20 sets
RA-SBP-20 box of 20 sets
For comparative and estimating purposes
NOTE: Add 25rV to pnoe when ordering in less than quantities indicated above.
8.40 8.40 11.55 11.55 17.64 17.64 10.50 3.36 10.50 3.20 12.60 14.70 8.50 6.50 4.41 2.10 2.21 5.46
7.40 14.55
4 4 9 9 10 10 3 4 2 2 5 3 9 9 4 -- -- 5
5
HH-11 See page 56
Page 42
02444
rSl AMERICAN iS STANDARD
HYDRONIC HEATING
HEATRIM PANELS
MODEL SS HEATRIM PANELS, ELEMENTS AND ACCESSORIES
Commercial baseboard panels designed for hotels, motels, apartments, hospitals, schools and churches The SS Heatrim is ideal for residential "hard to heat" areas such as bathrooms, hallways, etc
SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS (For yt" Model SS75 and 1" Model SS-100 Panels)
DESCRIPTION
ordering number
packaged per
^Trade Price
approx.
hipping weigh!
MODEL S5-75 COMPLETE UNITS
(Dual Pack)
Box includes 2 each of front and back panel, % " element, damper, necessary support brackets and slide cradles and 1 joining piece set. Finished with off - white prime paint.
Ordering Example:
1-box SS-75-6
SS-75-2 SS-75-3 SS-75-4 SS-75-5 SS-75-6 SS-75-7 SS-75-8
per lineal foot $ 3.20
Two 2 ft. lengths Two 3 ft. lengths
Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft lengths
$12.80 19.20 25.60 32.00 38.40 44.80 51.20
14 20 26 33 39 46
52
MODEL SS-100 COMPLETE UNITS (Dual Pack)
Box includes 2 each of front and back panel, 1" element, damper, necessary support brackets and -slide cradles and 1 joining piece set. Finished with off - white prime paint.
Ordering Example: 1--box SS-100-5
SS-100-2 SS-100-3 SS 100-4 SS-100-5 SS-100-6 SS-100-7 SS-100-8
per lineal foot S 3.55
Two 2 ft. lengths Two 3 ft. lengths
Two 5 ft. lengths Two 6 ft. lengths
Two 7 ft. lengths
Two 8 ft. lengths
14.20 21.30 28.40 35.50 42.60 49.70 56.80
14
20
26 33 39 46 52
MODEL SSI-75 COMPLETE UNITS (Single Pack)
Box includes 1 each of front and back panel, % " element, damper, joining piece set and necessary support brackets and slide cradles. Finished with off-white prime paint.
Ordering Example: 1-box SSI -75-7
SSI-75-2 SSI-75-3 SSI-75-4 SSI-75-5 SSI-75-6 SSI-75-7 SSI-75-8
per lineal foot S 3.35
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
6.70 10.05 13.40 16.75
20.10
23.45 26.80
7
11 14 18 21 25 28
MODEL SSI-100
COMPLETE UNITS
(Single Pack)
Box includes 1 each of front and back panel, 1" element, damper, joining piece set and necessary support brackets and slide cradles. Finished with off-white prime paint.
Ordering Example: 1-box SSI-100-6
SSI-100-2 SSI-100-3 SSI-100-4 SSI-100-5 SSI-100-6 SSI-100-7 SSI-100-8
per lineal foot S 3.70
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft length
7.40
11.10
14.80 18.50
22.20
25.90 29.60
7 11 14 18 21 25 28
For comparative ana estimating purposes only
See page 56
Page 43
HH-11
02445
HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES
AMERICAN Si STANDARD
HYDRONIC HEATING
MODEL SS HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES
Commercial baseboard panels designed (or hotels, motels, apartments, hospitals, schools and duirrhc I he SS Hcairim is ideal for residential "hard to heat" areas such as bathrooms, hallwavs, etc
DESCRIPTION
pockogid per
approx
(hipping
weight
MODEL SS
ENCLOSURES ONLY
(Bulk Pack) Box includes 4 each of front and back panel, damper, necessary support brackets, connecting tube wire hangers and 3 joining piece sets. Finished with off white prime paint. Ordering Example:
1--box SS-B
MODEL SSI ENCLOSURES ONLY
(Single Pack) Box includes 1 each of front and back panel, damper, joining piece set, necessary support brackets and connecting tube wire hangers. Finished with off white prime paint.
Ordering Example: 1-box SSI-6
ES-75-8 (% " tube) ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of %" element and necessary slide cradles. Ordering Example:
1-box ES-75-B
ES-100-8(1" tube) ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of 1" element and necessary slide cradles. Ordering Example:
1-box ES-100-8
SS-3 SS-4 SS-5 SS-6 SS-7 SS-8
SSI 3 SSI-4 SSI-5 SSI-6 SSI-7 SSI-8
ES-75-8
ES-100-8
per lineal toot $1.65
Four 3 h lengths Four 4 ft lengths Four 5 ft lengths Four 6 ft, lengths Four 7 ft. lengths Four 8 ft lengths
$19.80 26.40 33.00 39.60 46.20 52.80
per lineal foot $1.85
3 ft length 4 ft. length 5 ft length 6 ft. length 7 ft length 8 ft length
$ 5.55 7.40 9.25
11.10 12.95 14.80
per lineal foot SI.55
Eight 8 ft. lengths $99.20
per lineal foot $1.90 E ight 8 ft. lengths $121.60
31 42 52 63 73 84
11
14 18 22 25 29
42
48
ACCESSORIES
R. H. 2V6" End Covers (Short of Floor) .............................................. .. . L. H. 2VL" End Covers (Short of Floor) .................................................. . . R. H. 2%" End Covers (Extend to Floor) .............................................. ...
L. H. 2hi" End Covers (Extend to Floor) ............................................... R. H. 6" End Covers (Short of Floor)....................................................... . .
L. H. 6" End Covers (Short of Floor).......................................................
R. H. 6" End Covers (Extend to Floor) ...................................................
L. H. 6" End Covers (Extend to Floor)................................................ Inside Corner Covers .................................................................................... . .
R. H. Valve Enclosures with hinged access door.................................
L. H. Valve Enclosures with hinged access door...................................
R. H. Valve Enclosures with hinged access door & knockout for
mainless installation.........................................
...
L. H. Valve Enclosures with hinged access door & knockout for
mainless installation ..................................................
Wall End Pieces (Short of Floor) ..
....
Wall End Pieces (Extend to Floor).....................
Outside Corner Covers..................................
14'' Filler Pieces....................
.........
2" Joining Piece Sets ...
............
Support Brackets, Slide Cradles, Damper Clips
Return Pipe Hangers
Damper Joiners
Connecting Tube Hangers....................
SS-ECR-25S SS-ECL-25S SS-ECR-25F SS-ECL-25F SS-ECR-06S SS-ECL-06S SS-ECR-06F bb-tLiL-Ut)F SS-IC-90 SS-VER-06H SS-VEL-06H
SS-VERK-06H
SSVELK-06H SS-WEP-25S SS-WEP-25F SS-OC-90 SS-FPS-14 SSJPS-02
SS-SBP-24 SS-WHR-50 SS-DJ-50 SS-WHS-50
Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 1 2 Box of 12 Box of 12 Box of 12
Box of 12
Box of 12 Box of 12 Box of 12 Box of 4 Box of 6 Box of 24 Box of 24 Box of 50 Box of 50 Box of 50
$ 11.55 11.55 14.70 14.70 15.75 15.75 17.85 17.85 7.35 31.50 31.50
32.00
32.00 4.75
5.25 12.60 12.60
5.30
10.50 5.25 3.95 6.30
8 8 9 9 7
7 7 7
5 13 13
13
13 4
4
5 14
4
10 1
1
3
for comparohvt ond ejtimotmg purpose* only
*
Note Add 25% to price when ordering in less than quantities indicated above
HH-11
Page 44
See page 56
a
02446
,_|AMERICAN Si STANDARD
HYDRONIC HEATING
RADIANTRIM BASEBOARD PANELS SEE CURRENT LITERATURE FOR APPROVED
> l = B=R STEAM AND HOT WATER RATINGS
BASEBOARD PANELS
RADIATORS RADIATOR ACCESSORIES
Steam Rating per lineal foot 3.4 sq ft
per lineel foot Trade Price- $5.39
per square foot $1.58
Model 10 Radiantrim Panel lengths (2V4 ft to 30 ft) are made
up from the following sections:
1 Vi ft Left hand end section
1 ft Right hand end section
2 ft Left hand end section
2 ft Right hand end section
2 ft Center section
Assembly length with legs and tappings at each end:
1V4 ft Double end section
2 ft Double end section
For purpose of estimating shipping weights, use 43/ pounds per sq. ft..
16.15 pounds per Imeal foot
Model 10 Accessories
^Vhc
width
6 tube 4, 6 tube
4 tube
height, Inches sq ft per section Trade Price per sq ft
32 3.7 25 2.0, 3.0 19 1.6
$2.40 1.88 2.00
Arco Radiators are regularly furnished with two and onehalf inch (2 Vi") legs. Available on Special Order with four and one-half inch (4H") legs, or without legs--Price on application. Arco Radiators sold only in even number of sections up to a maximum of 56 sections.
For purpose of estimating shipping weights, use 4^ pounds per sq. ft.
Ordering Example: 1-12 Section 25" Arco 4 Tube Vi x Vi
SUNRAD RADIATORS
Extension Panel with 3 Brackets
Two 6 ft lengths per box............................................ $17.72
Extension Panel Retaining Bracket........................
.50
Extension Panel Cover Strip...................................
.72
I Assembly Clamp........................v............................... 11.83
Important: Increase size 5% for re cessed installation--air space top and sides, V\" at back. Increase size 15% for tightly recessed installationno clearance top or sides, V\" air space at back.
Short-Compression Corner Connection................
2.86
Long-Compression Corner Connection................. 3.85
typ.
sq ft per section
Trade Price per sq ft
Retaining Block ......................................................... Adjustable Leg ...........................................................
.21 .30
M 5 x 20
2.25
$2.30
Tie Bolt ...................................................................... .11 Sunrad Radiators are regularly furnished with legs and two-
These items are regularly furnished as required with Model 10 Ra diantrim Panels and Accessories. Prices are shown for repair or re
placement purposes.
Packed in quantity of 10 per box
^'phm
(Available only in this minimum quantity) par box or 10
pipe inside connections. Available on special order with onepipe connections, outside tappings or without legs--Price on application.
Sunrad Radiators sold in even number of sections from 4 to
Inside Corner Cover .................................................. $17.60 Extended Inside Corner Cover................................... 31.90
30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections.
Outside Corner Cover.................................................... Valve Enclosure (all R.H. or L.H.) ............................ End Box (all R H or L.H.) ........................................ 10" Plain Extension Piece......................................... Extension End Piece (all R.H. or L.H.) ......................
Ordering Example: 1--7 ft. Model 10 Radiantrim Panel. 1-Bok of Model 10 Right Hand Valve Enclosures.
23.65 24.20 13.20 15.38
9.46
Sunrad Grilles
Inlet--Stamped Lattice Type
per section $0.29
Special No. 16 Gauge with Locking Device ....................... Price on application
For purposes o/ estimating shipping toeights,
use 6 pounds per sq it
Ordering Example: 1-10 Section M5 x 20 Sunrad T-4 Vi i ^ 1--Type M Sunrad Grille for above.
EXTRA RADIANTRIM ACCESSORY BAGS
Bag No.
For
Trade Price
0 Double Leg Section 2%'-6' Panel Length
2 6%'-12' Panel Length 3 12 VS'-18' Panel Length 4 18%'-24' Panel Length 5 24V4--30' Panel Length
$ .95 1.19 2.54 3.78 4.97 6.39
Sufficient quantities of these bags are regularly furnished
aswith Radiantrim Panels. Prices shown are for extra bags may be required.
RADIATOR ACCESSORIES
Trade Price each
Arco Brackets
for 4 and 6 tube, with Wail Plate
... $1.21
Arco Radiator Pedestals
'/?' and 1"
.......................................................
59
Sunrad Brackets
Nipples, Plugs, Bushings, etc.
1", 1%", IVi" Plugs, Bushings V, 1", IVi" Slip Nipples.....................................................................
.32 .32
1/8" Air Vent Plugs ...
Radiator Rod Nuts .
...
.01
Radiator Rods
per section
.01
ADove items available for use only with our Radiator products.
.02
'W See page 56
Page 45
HH-tl
*47 .92
02447
convectors
____ _
^AMERICAN
KSiSTANDARD
HYDRONIC HEATING
MULTIFIN CONVECTORS TYPE K - STOCK MODEL - FREE STANDING Expanded prices
For use on two-pipe steam and hot water systems only.
CdblASf length in<hsi
No. 4 depth (4Vi" cabinet)
nil M.
K ft Mlpm
#PPM. chipping waifht
Trod* frit*
20" cabinet height
No. 6 depth (6 >4" cabinet)
unit a.
H 1 ufpuf
pprai. shipping weight
Trod* frit*
No. 8 depth (8Vi" cabinet)
unit it.
10 ft output
pprat. shipping wsight
Tradt flics
No. 10 depth (10*/," cabinet)
s It autpvt
oppros.
ihipping Trade
watghf
frit*
20 420-20 24 424-20 28 32 36 40 44 48 56 64
10.6 13.0
18 20
$21.85 23.20
620-20 14.9
624-20 18.4
628-20 22.0
632-20 25.5
636-20 29.0
64C--
32.5
644-20 36.1
648-20 39.6
656-20 664-20
46.7 53.8
21 24 27 29 33 34 37 40 45 52
$24.25 26.20 28.20 30.20 832-20 32.15 836-20 34.10 840-20 36.10 38.10 848-20 42.05 856-20 46.05 864-20
31.7 36.0 40.4
49.2 58 0 66 9
33 37 39
46 51 59
$33.65 36.05 1036-20 38.50 1040-20
45.5 51.2
42 48
43.45 1048-20 48.40 1056-20 53.35 1064-20
62.3 73.4 84.5
52 5B 64
$41.40 44.55
50.80 57.00 63.20
24" cabinet height
20 420-24 24 424-24 28 428-24 32 36 40 44 48 56 64
12.1 14.9 17.8
20 22 25
$22.70 620-24 17.2 23 24.25 624-24 21.2 26 25.85 628-24 25.4 30 632-24 29.5 33 636-24 33.5 35 640-24 37.6 38 644-24 41.7 42 648-24 45.7 44 656-24 53.9 50 664-24 62.2 57
$25.55 27.75 30.10 32.45 832-24 34.65 836-24 36.95 840-24 39.25 41.50 848-24 46.10 856-24 50.75 864-24
35.6 40.5 45.5
55.4 65.2 75.3
38 40 44
50 55 63
$35.85 38.60 1036-24 41.40 1040-24
49.0 55.2
45 52
46.90 1048-24 52.40 1056-24 56.05 1064-24
67.1 79.0 92.0
62 64 71
$43.35 46.80
53.50 60.15 66.85
32" cabinet height
20 24 28 32 36 40 44 48 56 64
620-32 18.7 29 624-32 23.1 32 628-32 27.7 36 632-32 32-2 40 636-32 36.5 43 640-32 41.0 48 644-32 45.4 56 648-32 49.8 58 656-32 58.7 67 664-32 67.8 71
$26.35
28.85
31.40 33.90 832-32
40.9
36.35 836-32 465
38.85 840-32 41.30
52.2
43.80 848-32 63.6
48.75 856-32 74.9
53.85 864-32 86.5
45 48 56
65 73 76
$38.80 41.95 1036-32 45.15 1040-32
55 0 61.9
54 59
51.50 1048-32 75.3 57.85 1056-32 88.7 64.35 1064-32 102.2
69 76 84
$46.70 50.55
58.05 65.55 73.15
Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 45.
Note: For stock model cabinet extras, see page BO. Ordering Example:
l-K-636-32 Multifin.
HH-11 See page 56
Page 46
^AMERICAN Si STANDARD
HYDRONIC HEATING
CONVECTORS
Type K (Stock Model) Type F (Special Service)
Type S
Type FS
MULTIFIN CONVECTORS
Combination Price:
The actual output in square feet of catalog rating-Steam (215"?.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination. The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered.
SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS
type
description
'W Trad* Price
09 r Q ft
unit extra charge
Stock Model
K
Floor Type--free standing..............................................................
$0.56
$15.90
Note: Price shoum for estimating purposes only. For expanded prices, see page 16. For cabinet extras, see page 50.
Special Service
F FG
w
FS - FSG
S
FR FRG FRGB
PR PRG
PRGB
Floor Type-free standing.............................................................. Floor Type--free standing-inlet grille...................................... Wall Hung--flat top..........................................................................
Free Standing--sloping top............................................................ Free Standing-sloping top-inlet grille.................................... Wall Hung-sloping top..................................................................
Fully recessed-^," beveled edges.............................................. Fully recessed--^*" beveled edges-inlet grille...................... Fully recessed-^*" beveled edges-inlet grille with
bottom overlap and liner bottom............................................
Partially recessed-1 W, 2 W', 3", 5" flanged edges .......... Partially recessed--1*", 2Vfe", 3", 5" flanged edges-inlet
grille ................................................................................................ Partially recessed--1V&", 2Vfc", 3", 5" flanged edges-inlet
grille--with bottom overlap and liner bottom....................
$0.67 .67 .67
.63 .63 .63
.68 .68
.68
.70
.70
.70
$19.28 22.15 19.28
20.34 23.22 18.32
20.34 23.22
25.56
23.54
26.31
33.76
TypeW
(Typo FRGB shown)
See page 56
Note: For cabinet extras, see page 50.
For estimating purposes only, the following approximate shipping weights per sq ft may be used for Multifln convectors:
Multifin stock model -- 1.13 pounds. Also see page 46.
Multifin cabinets (less element) -- 1% pounds.
Multifln cabinets (with element):
Types F, FR, PR - 1% pounds.
Types FS, W
-1 % pounds.
Type S
-1 Vi pounds.
Ordering Examples:
Stock Model Multifin with an optional feature: 1 K-840-24 Multitin with Metal Trim Strips.
Special Service Multifin with an optional feature: 1 PR-640-32-2Vi Flange, Multifin with Knob Damper.
Pa047
HH-11
02449
CONVECTORS
f51 AMERICAN IS STANDARD
HYDRONIC HEATING
MULTIFIN CONVECTORS - continued
convector length Inches
20 24
28 32 36
40 44 48 56 64
Elements only (when sold less cabinets) -- two-pipe steam or hot water
No. 4 depth
No. 6 depth
No. 8 depth
No. 10 depth
unit no.
approx. shipping
weight
Trade Price
unit no.
approx. shipping
weight
Trade Price
unit no.
approx.
shipping Trade
weight
Price
unit no.
approx. shipping
weight
Trade Price
420 8 $12.60 620 13 $15.45 820 15 $18.25 1020 21 $21.00
424
10
13.65 624 16
16.95 824
19
21.10 1024
26
24.35
428 432 436
12 14 16
14.70 628 19 15.80 632 22 17.15 636 25
18.45 828 23 19.75 832 27 21.25 836 31
22.60 24.60 26.80
1028 1032 1036
31 36 41
27.15 29.80 32.90
440 444 448
18 20 22
18.45 640 28
19.70 644 31
20.85
648
34
23.05 24.60 26.30
840 844 848
35 39 43
28.70 30.85 32.85
1040 1044 1048
46 51 56
35.50 38.00 40.40
456 464
26 30
23.20 25.65
656 664
40 46
29.30 32.65
856 864
51 59
36.70 40.65
1056 1064
66 76
45.00 50.50
Not*: Elements only are furnished less floor supports. Multifin elements for special one-pipe steam header appiicatlon-not available.
Ordering Example: 1-420 Multifin Element only--no cabinet.
Ratings:
Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-4? and amendments and said ratings have been approved by the Convector Rating Committee.
Standard Cabinets:
Standard cabinets are furnished in prime painted sheet steel--reinforced. No. 18 gauge front and No. 20 gauge back, ends and top, rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors as cur rently catalogued.
MINIMUM CABINET HEIGHTS WITH DAMPERS FOR MULTIFIN AND ARCO CONVECTORS
Type cabinet
F, FG W FS. FSG S FR.FRG.FRGB PR. PRG, PRGB
Multifin
20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths
Arco Cast Iron
24" For all depths 24" For all depths 24" For all depths 24" For #4, #6, #8 depths-32" For it 10 depth 20" For all depths 20" For all depths
Cabinet heights shown for types W and S are nominal heights, actual heights are 5" less. Cabinet heights for Arco Cast Iron convectors applicable to X-4 (underneath) connections only.
hh-11 "W See page 56
Page 48
02450
AMERICAN LS STANDARD
HYDRONIC HEATING
CONVECTORS
ARCO CONVECTORS
SPECIAL SERVICE LINE when sold in combination with standard cabinets
COMBINATION PRICE:
The actual output in square feet of catalog rating-Steam (215F> obtained with the cabinet heights furnished deter mines the price of convectors and cabinets sold in combination
The total price of each order equals the amount of catalog square feel ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of
units ordered
SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS
cabinet type
description
Trade Price
per sq ft
unit extra charge
F Floor Type-free standing
$2.17
FG Floor Type-free standinginlet grille .......................... 2.17
w Wall Hung-fiat top
... 2.17
FS Free Standing-sloping top
2.17
FSG Free Standing-sloping top-
inlet grille
................
2.17
S Wall Hung--sloping top
2.17
FR Fully recessed-%6" beveled edges .......................................... 2.17
FRG Fully recessed--beveled edges-mlet grille................ 2.17
FRGB Fullv recessed-^" beveled edges-inlet grille with
bottom overlap and liner
2.17
$26.94 30.23 26.94 28.34 31.50 28.34 26.94 30.23
32.89
cabinet type
description
PR Partially recessed-1 Vi". 2Vs", 3". 5" flanged edges . . . .
Trade Price
per sq ft
unit extra charge
$2.25 $31.12
PRG
Partially recessed-1 xk", 21,a,\ 3". 5" flanged edges-inlet
grille ......................................
2.25
34.28
PRGB Partiallv recessed-1 V2". 217". 3". 5" flanged edges-inlet
grille--with bottom overlap
2.25
42.38
Standard Cabinets are furnished in:
Prime painted sheet steel-reinforced, No 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors listed m cur rent literature.
For illustrations of cabinets, see page 4 7
For cabinet extras, see page 50.
Ordering Example: l-F-458-20 Arco Convector Unit X-4 vA y \2
For estimating shipping weights of Arco Convector Units use: IVz pounds per square foot for cabinet portion 3Vz pounds per square foot for element portion.
ARCO CONVECTOR -- steam or wafer
ELEMENTS ONLY (when sold less cabinets)
convector length Inches
18 23 28 33 38 43 48 53 58 63
No. 4 33,4" depth
unit
no.
approx.
shipping ^Trade
weight
Price
418 39 $20.11
423 50 26.06
428 61 31.88
433 72 37.77
438 83 43.59
443 94 49.34
448 105
55.10
453 117
60.97
458 128
66.79
463 139
72.74
No. 6 55/8" depth
unit no.
approx.
shipping ^Trade
weight
Price
618 57 $ 29.67
623 73
38.27
628 90
46.87
633 106
55.66
638 123
64.26
643 139
72.93
648 146
81.47
653 172
90.07
658 189
98.74
663 206
107.47
No. 8 7%" depth
unit no.
approx.
shipping vTrade
weight
Price
No. 10 9i/2" depth
unit no.
approx.
shipping ^Trade
weight
Price
818 71 $ 37.39 1018 84 $ 45.03
823 92
48.39 1023 no
58.26
828 113
59.40 1028 136
71.60
833 134
70.28 1033 162
84.76
838 155
81.09 1038 188
98.11
843 176
92.09 1043 213
111.32
848 197
103.10 1048 238
124.67
853 218
114.10 1053 264
138.01
858 239
125.05 1058 289
151.24
863 260
135.99 1063 314
164.39
Ordering Example:
1--418 Arco Cast Iron Element only-No Cabinet X-4 Vi x V2
Arco Convectors in lengths and depths indicated above are Standardized Sizes when sold with or without cabinets
For sizes not listed above-price on application
See page 48 for minimum cabinet heights with dampers.
"W See page 56
Page 49
HH-11
02451
CONVECTORS
(AMERICAN STANDARD
HYORONIC HEATING
CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS
CABINET EXTRAS-STOCK MODEL MULTIFIN ONLY
ITEM
DESCRIPTION
DAMPER
METAL TRIM STRIPS
Knob Operated Damper Package.................................... ............ each
For recessing stock models only
20" to 36" long................................................................
. .. each
40" to 64" long .............................................................................. .............. each
GRILLE AIR VENT
Snap-on Inlet Grille for Stock Models Only ....................
Air chamber with extended tube, manual vent ................ Air chamber with Dole No. 20JR auto-vent......................
'Note: Items also available for special service Multifin.
'W Trade Price
$ 5.50
9.45 12.10
4.20
5.35 5.35
SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS (Prices indicated are for standard catalogued sizes only)
ITEM
DESCRIPTION
"W Trade Price
DAMPER
Knob or Institutional Type .................................................................... each
% 6.55
ACCESS DOOR TAMPER PROOF
SCREWS CAM LOCKS
INSULATION
In standard locations 1, 2, 3, 4, 7 or 8 as shown in current literature.
-- Hinged type with Slotted Head operator .............................................. each Hinged type with Allen Head operator .................................................. each Note- Access doors in other than standard locations
6.55 7.80
Price on application
Phillips or Allen Head screws (other than standard Slotted Head) per cabinet
1.05
Allen Head Cam Locks (Allen Keys Not Furnished)-
Types F, FG. FS and FSG........................................................ per cabinet
Types S and W (Multifin Only) ..................................
.. per cabinet
TyT FRJ,,RG'
PR' PRG' PR,GB10ver4488' . ` `' per cablnel
Note: Additional charge per order $5.20
5.40 5.40 23.80 29.80
Vz " Celotex or Fibreglas on outside of cabinet Back only...................................................................................... per cabinet Back, ends and top......................................................................................... percabinet
Vz" Millboard on outside of cabinet Back only........................................................................................ per cabinet
Back, ends and top........................................................................................ percabinet
11.10 13.70
26.00 36.95
SOUND DEADENING MATERIAL
Approx. Vfe" thick--inside front panel only................................ per cabinet
11.00
SEALING STRIP
For standard length FR, FRG and FRGB cabinets only (V4" x Polyurethane) ........................................................ per cabinet
-4.60
STIFFENER
All fronts 48" and longer, or 32" and higher have stiffening channel spotwelded to inside front in horizontal position at no additional charge. Stiffening channel on fronts other than standard ............................................................................................. per cabinet
1.55
METAL TRIM STRIPS
For recessing Types F and FG Multifin convectors only
Cataloged heights and lengths up to 36"............................................ each Cataloged heights and lengths 40" to 64".......................................... each
10.60 13.05
END POCKETS
Specify right or left hand side
4" end pocket with No. 18 gauge vertical baffle............ per end pocket 8" end pocket with No. 18 gauge vertical baffle............ per end pocket
5.90 9.45
KNOCKOUTS
Are optional-Furnished only on request
Price on application
HEAVIER GAUGE CABINETS
HH-11 See page 56
Trade Price per square foot of cabinet output Front Only
No. 18 gauge........................,...............
No. 16 gauge........................................ No. 14 gauge.........................................
$--
.07 .14
Page 50
Liners Only
$.07 .09
not available
02452
^AMERICAN csJSTANDARD
HYDRONIC HEATING
general
INFORMATION
BOILER RATINGS
The pc: 1 -- B -- K boiler ratings represent the maximum net loads that may be connected to the boilers. The net I -- B = R steam ratings are based on a piping and pickup allowance of 1 333 except where an appropriate piping and pickup column shown. Steam sq. ft. ratings are based on 240 Btuh per sq ft. The net I --B=:R water ratings in Mbh are based on a piping and pickup factor of 1.15. Water sq. ft. rating' are based on 150 Btuh (17CF water) per sq. ft. For installations having unusual piping and pickup requirements, AmericanStandard should be consulted before selecting a boiler.
For forced hot water heating systems where the boiler and
piping are within the area to be heated, the boiler may be selected on the basis of its gross output
Sufficient radiation must be installed for the requirement' of the building to be served.
In order to select the proper size bode:, calculate the heat loss of the building, then divide thm figure by 1.000 to get the heat loss expressed in Mbh .Select a 'team or water boiler which has a net I = B=;R Mbh rating equal to or greater than this figure using the appropriate steam or water column.
See current literature for determining the size of radiatorand convectors for hot water system'.
GAS FIRED BOILERS
American-Standard Gas boilers are design certified by the American Gas Association.
Ratings shown are for installation at sea level and at elevations up to 2,000 feet. For altitudes above 2.000 feel, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
OIL FIRED BOILERS
The firing rates or 1 = B = R burner capacities -- gallons per hour--are based on the use of oil having 140,000 Btu per gallon heat value.
STOKER FIRED BOILERS
The firing rates or I = B=rR burner capacities--pounds pei hour--are based on the use of coal having 13,000 Btu per pound heat value.
HAND FIRED BOILERS
The ratings are based on the use of stove or nut size bitumi nous coal, anthracite coal or coke with 13,000 Btu per pound heat value. See table below for selecting proper size boiler when using coal with less than 13.000 Btu per pound.
BUILT-IN TANKLESS WATER HEATERS for G-2 Water, G-40, G-10, A-3, FR-A-5, and A-5
All tankless type built-in water heaters are rated m gallons per minute on the basis of a minimum boiler water temper ature of 200 F. The maintaining of 200 F boiler water temperature with rated flow through a tankless type builtin water heater is dependent on the output of the boiler.
Increase the boiler size 12 Mbh for each
m exce?.-
of two.
In those areas where excessive lime exi?'> m the watei
use of built-in tankless type water heatei i? not recom
mended except when provision is made foi legulaih clean
ing the heater.
EXTERNAL WATER HEATERS FOR AMERICAN-STANDARD STEAM BOILERS
External tank or tankless type heaters can be connected to all American-Standard Steam boilers when provision is made in the supply and return piping of the heating system.
When an external tank type heater is used and the domestic demand exceeds 75 gallons in a 24 hour period, increase the boiler size 120 Btuh for each gallon of storage tank capacity.
When an external tankless type heater i- used, increase the boilei size 12 Mbh for each bathroom m exces" of two.
(Note: G-10 Steam boilers can be provided with external water heater tappings for water to water heal exchangers. See G-10 optional equipment page^- foi price and availabil ity. A-7 boilers are regularly provided with tappings for external water to water heat exchange)' i
WHERE COAL HAS LESS THAN 13,000 BTU CONTENT
When selecting hand fired boilers for burning coal of lower heating value than 13,000 Btu per pound the following cor rection factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq. ft.).
heating value of coal
13,000 12,500 12.000 11,500 11,000
correction factor
1.00 . 1.04
1.08 1.13 1.18
heating value of coal
10,500 10,000
9.500 9,000
correction factor
1.24 1.30 1.37 1.44
INSTRUCTIONS FOR ORDERING GAS BOILERS:
Specify complete boiler number
Specify type of gas (whether natural or propane). Btu (heat value of gas), specific gravity
Specify elevation at point of installation if m excess of 2,000 feet and indicate barometric pressure
In addition, for Pressure Fired PfA-5 gas fired ond gos-oil fired units, specify gas pressure at gas train inlet
Specify optional equipment in detoil
REPAIR PARTS --TRADE PRICES BOILERS
Prices listed in Boiler Repair Parts Catalog Form 9100-2 Dated 3/1/71
Less 25%
Oil Burners
List Price Plus 21%, Less 25%
For List Prices see "American Standard Arcoflame Oil Burner Repair Parts Catalog" 1966 Edition,
HH-1 1
Page 51
02453
MEMO
02454
MEMO
02455
MEMO
02456
MEMO
02457
GENERAL TERMS
^AMERICAN LSstandard
HYDRONIC HEATING
TRADE PRICE BOOK
illustrations and descriptions ol ordering Numbers listed in this price book will be found in the current American-Standard Hvdromc Products Catalog and literature. Items illustrated in product literature and not included m this price book are discontinued The illustrations in this price book although actual representations of certain products in the line, do not necessarily show sizes ano details of all products m the line
^Tnis price list has been prepared for the convenience of American-Standard distributors and their trade customers only. The trade prices shown are guides only and do not purport to represent actual prices prevailing in any particu'ar market and are net intended to interfere with our distributors' right and responsibility lo establish their own resale prices
All prices herein set forth supersede alt prior price lists and are subject to change without notice Tne Seller may aisc. from time to time, discontinue without notice the sale of any of the products listed herein
INVOICE MINIMUM All distributors' orders, including repairs, which aggregate less than $15.00 net will be billed at $15.00
TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH U.S. PLUMBING/HEATING TO ITS DISTRIBUTORS
All sales of goods by American-Standard through U.S. Plumbing/Heating to its distributors are maoe subject to terms and conditions printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms These terms and conditions, are as follows
PRICE
Goods sold by the Seller will be billed to the Buyer according to the pnees and terms contained in its current bulletins and price books In the case of orders tor goods for which no price is currently in effect the price will be determined by the Seller and set forth m the invoice issued after shipment of the goods
Taxes. Any tax or other Government charge now or hereafter levied upon me orodveuen sale use or shipment of goods ordered or sold, will be charged to and paid lor by the Buyer
DELIVERY
Transportation Risks. Delivery-to the initial earner shall constitute delivery to the Buyer The Setter's responsibility ceases upon delivery in good order to suen earner and all goods are shipped at the Buyer's risk
The Buyer >s urged to examine all deliveries carefully before signing transportation receipts U goods are visibly damaged, the Buyer should insist that writien confirmation of the damage be noted on the freight bill or aray ticket by the agent of the earner If damage is discovered afier unpacking the carrier should be notified at once, so that inspection can be mace ano the claimed damage substantiated by the earner
Interference with Delivery. The Seller has no obligation to deliver goods against any order until it has accepted the order by issuance of its acknowl edgment of order in any event, the Seller will not be liable for any delay or failure in (he delivery or shipment of goods against an accepted order or for any damages suflered by reason thereof, when such delay or failure is. directly or indirectly, due to accident (in manufacture or otherwise), fire, flood, riot, war embargo labor stoppages, inadequate transportation facili ties shortage of material or supplies, delay or default on the part of its vendors, regulation by Government authority, or any. like or dissimilar cause beyond its control
CONSUMER PROTECTION - WARRANTY
American-Standard products normally reach owners or consumer-users through an industry channel of distributors Bnd plumbing and heating con tractors. Experience has shown that claims of defects m our products gen erally reiaie to abuse or to other damage which occur after our sale and are no! our responsibility Since determining proper responsibility requires local inspection, our warranty (set forth below) extends only lo our direct buyers, distributors are best equipped to obtain the facts underlying claims, to place responsibility wnere it belongs and to recommend,'handle repair or re placement
American-Standard warrants only to its distributors and other direct Buyers mai it will lurnish by freight a replacement for. or at its opiion repair any producl of its manulacture or part or portion thereof proved to its satisfac tion to be defective m material or workmanship under normal use ano service within one year after installation
There is no other warranty, express or implied, including no implied war ranty of merchantability or implied warranty for fitness for a particular purpose and American-Standard wilt not be responsible lor any damages whatsoever, nor for labor or transportation expenses relating to such re placement or such repair
Goods of other manufacturers sold by American-Standard are not warranted unless accompanied by an express written warranty, but the Seiler will endeavor to secure for its direct Buyers the benefits of warranties extended by such other manufacturers for such goods
American-Standard is proud of ifs recorc 'o< product quality and for fair ness m handling warranty matters anc d an ultimate user of our products should feel our warranty system desenoed above does not work fairly in his case ne should write Ihe Office of me Pres'deni Director of ConsumeAflairs U S Plumbing/Healing Amencan-Stanaard 40 West 40lh Street New York, N Y 10018
CONTRACT WITH BUYEn
Acceptance of Orders. Orders will be accepted omy ov me Seller s usua' acknowledgment of orcer containing termt arm cono'tions applicable thereto No terms and conditions appearing m a Buyer s orcer mar are a: variance with the Sellers terms anc conditions shall be pindina upon me Seller unless specifically agreed to by a m writing Unless the Seller spe cifically so agrees <n writing m acknowledging anv order any terms and conditions appearing in a Buyer s order contrary to those statec herein anc in such acknowledgment of order are to be deemed waived by the Buver Receipt by fhe Buyer of me acknowledgment of order without prompt ob.ee tion to the terms and conditions therein and herem set forth consMut? acceptance by the Buyer ol such terms and conditions
Cancellation of Orders. After the Seller s acknowledgment of order has been issued, an order may be modihec o- cancelled only upon written agreement By the Seller Orders for gooes omer man ihose of sianoarc manufacture will not be cancelled alter a commitment has been made cproduction scheduled
Credit for Returned Goods Merchandise nj, not be returned for credit unless the Seller has agreed to accept it Where returns are accepted a deduction of 10% or $10, whichever is greater will be made lor rehandling All transportation costs for returned goods must be paid by the Buyer In any evenl only saleable merchandise c( siandarc manulacture may be returned tor credit
Credit Approval. Buyers' orders are accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stopped m transit on accepted orders without any liability on the Sellers pan if. m its opinion, the Buyer s ability to pay for me merchandise on these terms and conditions is m doubt
SHORTAGES OR VARIANCES
No claims for variances from or shortages m orders will be considered unless presented within 60 days after receipt of goods
PRODUCT AND PACKAGING CHANGES
Factors beyond the control of me Seller anc me need for continuing im provement of product reautre the maxing of changes from lime (o time in producls and their packaging The right is reserved to make reasonable changes of any kind without noiice anc io deliver revised designs or models ol goods against any order unless or. the face of the acknowfedgment ol order this right is specifically waived
The Seller shall have no responsibility whatever with respecl to changes made by the manufacturer in products or meir packaging sold but not manufactured by the Seller
SHIPPING WEIGHTS
Tne shipping weights given nerem are approximate lor Buyers ccr vemence only, and are not guaranteed
AMERICAN STANDARD Inc
US PLUMBING'HE4 T tNG
HH-1 1
Page 56
02458