Document J3mYELdqaa57b7EZLwey5OLXv

O AMERICAN STANDARD trade price book for AMERICAN-STANDARD Hydronic Heating Equipment* Hvdromcs the science of heating and cooTing with water ` _________________ PRODUCTS________________ Boilers -- Cast Iron Electric Packaged Boilers Gas Packaged Units Boilers Electronic Control Systems Oil Packaged Units Boiler-Burner Units Flame Retention Boiler- Burner Units Boilers Oil Pressure Fired Gas Boiler-Burner Units Gas-Oil____________________________________ Coat Stoker Fired Hand Fired Oil Burners and Controls Comfort Computer -- Zone ViWe Packages Hydronic Assembling Tools Radiation: Baseboard Panels Heatnm Baseboard Panels. Radiantrim Radiators Arco, Sunrad Convectors Muttifin Arco Cabinet Extras Terms General Information Repair Parts Discounts Memorandum PAGE 39-40 2-6, 9 7, 8, 10-16 17 18-19 20, 22-30, 33 29, 30 21.22, 28, 31 -33. 36,37 23-28 36 37____ 33, 35 34 38 41-44 45 45 46-48 49 50___ 56 51 51____ 52-55 02401 PACKAGED boilers GAS FIRED WATER fS\ AMERICAN kS STANDARD HYDRONIC HEATING GPMX PACKAGED GAS BOILERS Completely factory assembled and pre-wired. Two-toned brown and beige jacket encloses all controls. Regularly supplied for 115 volt 60 cycle power supply with 24 volt system; self ener gizing controls when specified at no extra charge. Built-in purge valve--Patent applied for. Built-in air separator, in left-hand end section. Intermittent circulator operation. Design certified by A. G. A. for combustible floor and closet installations. Cast iron drilled port burners are standard equipment for natural gas. Ribbon burners are standard for propane gas -- optional for natural gas at 10% reduc tion of rating as indicated by model number suffix R. Tested and equipped for 30 lbs. water working pressure. Ratings shown are for installation at sea level and up to 2,000 feet. WATER -- for natural gas -- 100% shut-off pockoged boiler number GPMX-3 GPMX-4 GPMX-5 GPMX-6 GPMX-7 GPMX-8 A G.A input Mbh 66 99 132 165 198 231 A.G.A. output Mbh 52.8 79.2 105.6 132.0 158 4 184.8 nel l = ft rating Mbh 46.1 68.7 92.2 114.8 137.4 160.9 net rating tq ft water Trade Price with standard equipment 307 458 615 765 916 ____10_7_3 ___ $310.00 339.00 387.00 442.00 496.00 550.00 approx chipping weight 197 240 284 335 381 428 | chimney me mtide i diam. m ;4 ;5 5 6 7 7 heighr feel 10 10 10 10 10 10 WATER -- for propane gas-- 100% shut-off GPMX-3R GPMX-4R GPMX-5R GPMX-6R GPMX-7R GPMX-8R 60 90 120 150 180 210 48 72 96 120 144 168 41.7 62.6 83.5 104.3 125.2 146.1 278 $310.00 417 339.00 557 387.00 695 442.00 835 496.00 974 550.00 197 240 284 335 381 428 4 5 5 6 7 7 10 10 10 10 10 10 Ordering Examples: 1. Pockoged boiler with ttandord equipment: 1 GPMX-6 boiler with 24 volt control) Not. gat, 1000 Btu, .6 tg. 2. Pockaged boiler with optional equipment: 1 GPMX-7R boiler with 24 volt controlt for constant circulator operation. Nat. gas, 1000 Btu, .6 ig. 1 conversion kit from natural to propane gas Standard Equipment V81 series manifold gas valve includes main operator, manual shut-off, pilot filter, pressure regulator (except for propane gas) and Pilotstat. 1XA" Circulator with Piping Drain valve ASME relief valve, 30 lb. Draft Hood Wiring Harness Purge Valve Expansion Tank Auto Air Vent Automatic Fill Valve Specify 24 Volt . . . or . . . Specify Self Energizing T822D thermostat T822D thermostat L4080D limit control L8148G limit and circulator relay (40VA) R8226B transformer (40VA) and circulator relay Note: Boiler is shiDDed with jacket, all controls, circulator, main burners and manifold controls and piping factory installed and wired. Purge valve, air vent and expansion tank installed. Relief valve and thermostat fastened inside boiler crate. Draft hood shipped separately. Optional Equipment Optional constant circulation (24 V) L4081B limit and reverse acting circulator controls with AT20Dtransformer instead of L4080 and R8226B. Furnished at no additional charge. Optional constant circulation (S.E.) L4081B limit and reverse acting circulator control and TS822A thermostat instead of L8148G and T822D thermostat. Furnished at no additional charge. Conversion Kits: Boilers must be specified with suffix letter R. Reduced propane ratings apply. Natural to Propane gas Propane to Natural gas Trade Price $6.50 Trade Price $6.50 Zone valve packages are available for water boilers. For details and prices, see page 34. HH-11 See page 56 Page 2 02402 rsiAMERICAN LSJSTANDARD HYDRONIC HEATING PACKAGED BOILERS gas fired WATER GPM PACKAGED GAS BOILERS Completely factory assembled and pre-wired. Two-toned brown and beige jacket encloses all controls. Regularly supplied for 115 volt 60 cycle power supply with 24 volt system; self ener gizing controls when specified at no extra charge. Built-in purge valve--Patent applied for. Built-in air separator, in left-hand end section. Intermittent circulator operation. Design certified by A. G. A. for combustible floor and closet installations. Cast iron drilled port burners are standard equipment for natural gas. Ribbon burners are standard for Propane gas -- optional for natural pas :ti IO'/t reduction of rating as indicated by model number suffix R. Tested and equipped for 30 lbs. water working pressure. Ratings shown are for installation at sea level and up to 2,000 feet. WATER--for natural gas--100% shut-off pockoged boiler nvmber GPM-3 GPM-4 GPM-5 GPM-6 GPM-7 GPM-8 1 AGA 1 mpwi | Mbh | 66 ! 99 ! 132 165 1 198 231 AC.A Mbh 52.8 79.2 105.6 132.0 158.4 184.8 net rolmg Mbh 46.1 68.7 92.2 114.8 137.4 160.9 ------------- ! net roting tq fl wettr ^^Trode Price with ilandard equipment 307 458 615 765 916 1073 $287.00 317.00 366.00 421.00 475.00 529.00 approx ihipping weight 200 240 285 335 385 430 chimney me inudc height foot '5 i5 6 7 7 10 10 10 10 10 10 WATER--for propane gas--100% shut-off ' GPM-3R GPM-4R GPM-5R GPM-6R GPM-7R GPM-8R 60 90 120 150 180 210 48 72 96 120 144 168 41.7 62.6 83.5 104.3 125.2 146 1 278 417 557 695 835 974 $297.00 317.00 366.00 421.00 475.00 529.00 200 240 285 335 385 430 4 5 5 6 7 7 10 10 10 10 10 10 Ordering Examples: 1 Packaged boiler with ilandard equipment' I GPM-5 boiler with 24 volt controls Nat. gas, 1000 Btu, .6 sg 2 Packaged boiler with optional equipment. 1 GPM-3R boiler with self-energizing con trols for constant circulator operation. Propane gas See page 56 Standard Equipment V81 series manifold gas valve includes main operator, manual shut-ofF. pilot filter, pressure regulator (except for Propane gas) and Pilotstat. 1%" Circulator with Piping Draft Hood Drain valve Wiring Harness ASME relief valve, 30 lb. Purge Valve Specify 24 Volt . . . or . . . Specify Self Energizing T822D thermostat T822D thermostat L4080D limit control. L8148G limit and circulator relay (40VA) R8226B transformer (40VA) and circulator relay Note: Boiler is shipped with jacket, all controls, circulator, main burners and manifold controls and piping factory installed and wired. Relief valve and Thermostat fastened inside boiler crate. Draft hood shipped separately. Optional Equipment Optional constant circulation (24 V) L4081B limit and reverse acting circulator controls with AT20D transformer instead of L4080 and R8226B. Furnished at no additional charge. Optional constant circulation (S.E.) L4081B limit and reverse acting circulator control and TS822A thermostat instead of L8148G and T822D thermostat. Furnished at no additional charge. Conversion Kits: Boilers must be specified with suffix letter R. Reduced Propane ratings apply. Natural to Propane gas Propane to Natural gas $6.50 $6.50 Zone valve packages are available for water boilers. For details and prices, see page 34. Page 3 HH-11 02403 PACKAGED BOILERS GAS FIRED WATER rS! AMERICAN LSJstandard HYDRONIC HEATING G-2 PACKAGED GAS BOILERS Fully packed, pre-wired, and equipped with controls for forced circulation, the G-2 is a quality, time-proven cast iron gas fired boiler available with and without tankless heater for domestic water requirements. This modern deluxe jacketed boiler features the patented "Eliminaire" (cast-in air sep arator in the left end section) and the distinctive American-Standard brown and beige jacket color combination to dress up any basement or utility room. The boiler is tested and equipped for 30 lbs. water working pressure and i= regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system Self-eneigizing controls are avalable without extra cost. Ratings shown are for installation at sea level and up to 2,000 feet. WATER--for natural and propone gases--100% shut-off packaged number A.G.A. Input Mbh A.G.A. output Mbh tankless heater number t=:W=H rating net l=B=R rating Mbh net rating sq ft water Trade Price with standard equipment epprox. shipping weight chimney size inside height diam. in. feet Packaged boilers with factory installed tankless heater G-24-DPT G-25-DPT G-26-DPT G-27-DPT 90 120 150 180 72 96 120 144 Packaged boilers less heater 218 222 222 222 2 Vi 62.6 3 83.5 3 Vi 104.3 3 Vi 125.2 417 556 695 834 $466.00 521.00 573.00 620.00 416 481 551 620 5 10 5 10 6 10 6 10 G 23-DP G-24-DP G-25-DP G-26-DP G-27-DP 60 48 90 72 120 96 150 120 180 144 41.7 62.6 83.5 104.3 125.2 278 417 556 695 834 $367.00 431.00 482.00 534.00 581.00 333 403 472 542 603 4 10 5 10 5 10 6 10 6 10 AGailono of waier per minute heated Iron 40F to 140F with 2QQF boiler water temperature. Standard equipment V-81 Series manifold gas valve including mam operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat. 1 % " Circulator with piping ASME relief valve Draft hood (for G-23 only, shipped m separate carton) Pressure and temperature gauge Wi rine harness AT20D transformer (24V. less heater boilers only) Additional standard equipment for boilers with heater Tankless heater as listed above T822D (24V.) thermostat L8124E (24V.) or L8124B (S.E.) triple Aquastat relay Ordering Examples: 1. Packaged boiler less heater with standard equipment 1 C-24-0P boiler Nat. gas, 1000 8tu, .6 sg. 2. Packaged boiler with factory installed heater with optional equipment: 1 G-26-DPT boiler with ribbon burners and Nat to Propane conversion kit. Nat. gas, 1000 Btu, .6 $g. Additional standard equipment for boilers less heater T822D (24V.) or TS822A (S.E.) thermostat L4081B (24V. and S.E.) combination high limit and circulator control Note: Left hand end section less tankless heater opening Note: Shipped with jacket, all controls (except thermostat), circulator and piping, main burners and manifold controls and piping factory installed and wired. Thermostat, manual main gas and pilot gas shut-off valves and relief valve shipped in accessory box fastened inside boiler crate. Optional equipment Self-energizing controls (consist of VS81 Series gas valve, TS822A ther mostat, Q313 Thermopile Generator and limit or combination control as noted above), available when specified on order no charge L8148E (24V.) or L8148G (S.E.) combination limit/relay in lieu of L4081B furnished on G-2 DP boilers no charge Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit": order ................................................ G-23 thru G-27 ''Trade Price $5.70 Floor shield for combustible flooring. Add suffix letter "C" to boiler number add $3.30 Note: in areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above. Zone valve packages are available for water boilers. For details and prices, see page<34. HH-i i "W See page 56 Page 4 02404 PEI AMERICAN Si STANDARD HYDRONIC HEATING PACKAGED BOILERS GAS FIRED STEAM G-2 PACKAGED GAS BOILERS For steam installation on new work or modernization, the G-2 Pack aged Steam boiler is available with either Flush or Deluxe jacket in the smart and attractive brown and beige combination that labels it an American-Standard top performing cast iron boiler. This model is factory assembled and pre-wired for 115 volt, 60 cycle power supply with 24 volt control system. Where required, self-energizing controls are furnished without extra charge. Ratings shown are for installations at sea level and up to 2,000 feet. STEAM--for natural and propane gases--100% shut-off packaged boiler number A.G.A. Input Mbh A.G.A. output Mbh net l=B=R rating Mbh sq ft Trade Price with standard equipment flush Jacket deluxe Jacket approx. shipping weight chimney size inside diem. In. height feet G-23-SP* G-24-SP* G-25-SP* G-26-SP* G-27-SP* 60 48 90 72 120 96 150 120 180 _ 144 36 150 $308.00 $324.00 310 54 225 373.00 389.00 376 72 300 428.00 444.00 443 90 375 481.00 497.00 518 108 450 527.00 543.00 581 4 10 5 10 5 10 6 10 6 10 Add suffix letter "F" for flush or D" for deluxe jacket Ordering Examples: 1. Packaged boiler with standard equipment: l G-26-SP0 boiler Nat. gas, 1000 8tu, .6 sg. 2. Packaged boiler with optional equipment: 1 G-24-SPD boiler with self-energizing con trols Nat. gas, 1000 Btu, .6 sg. Standard equipment V81 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat. No. 67-GAR (24V. and S.E.) low water cut-off Gauge glass with trimmings Draft hood (for G-23-D and G-23-F thru G-27-F, shipped in separate carton) T822D (24V.) or TS822A (S.E.) thermostat PA404A (24V. and S.E.) pressure limit control AT20D transformer (except S.E.) ASME safety valve Steam gauge Floor pan and radiation shield Note: Shipped with jacket, all controls (except those noted below), main burners and manifold controls factory installed and wired. Thermostat, low water cut-off, manual main and pilot gas shut-off valves (when required), safety valve and steam limit control shipped in accessory box fastened inside boiler crate. Optional equipment Self-energizing controls (consist of VS81 Series gas valve; Q313 Thermo pile Generator; thermostat and limit control as noted above) available when specified on order no charge No. 101-24V. electric water feeder is available for addition to the No. 67-GAR to provide a low water cut-off and feeder combination control add $55.80 Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit": G-23 thru G-27 Trade Price $5.70 Note: ln areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above. For Additional Optional Equipment, See page 15. ' See page 56 Page 5 HH-11 02405 PACKAGED BOILERS GAS FIRED WATER d AMERICAN STANDARD HYDRONIC HEATING G-2 PACKAGED ALL-PURPOSE GAS BOILERS Versatile and packed with pluses. Can be used for forced circulation or gravity installations. Completely factory assembled, pre-wired and crated with Deluxe brown and beige style leading jacket. Patented "Eliminaire" ends air problems. Tested and equipped for 30 lbs. water working pressure and regularly fur nished for 115 volt, 60 cycle power supply with 24 volt control system. Self energizing controls available at no added charge. Ratings shown are for installation at sea level and up to 2,000 feet. WATER--for natural and propane gases--100% shut-off packaged boJIer number A.OA. Input Mbh A.G.A. output Mbh nt IsBsR rating Mbh net rating sq ft water Trade Price with standard equipment less thermostat G-23-DPG 60 48 41.7 278 $269.00 G-24-DPG 90 72 62.6 417 335.00 G-25-DPG 120 96 83.5 556 393.00 G-26-DPG 150 120 104.3 695 447.00 G-27-DPG 180 144 125.2 834 494.00 approx. shipping weight chimney size Inside diam. in. height feet 307 373 438 511 574 4 10 5 10 5 10 6 10 6 10 Ordering Eximples: 1. Packaged all-purpose boiler with standard equip ment: 1 G-25-OPG boiler Nat. gas, 1000 Btu, .6 $g. 2. Packaged all-purpose boiler with optional equip ment: 1 G-26-DPG boiler with self-energizing controls Nat. gas, 1040 Btu, .65 sg. HH-11 See page 56 Standard equipment V81 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat. L4080B (24V. and S.E.) immersion limit control ASME relief valve Pressure and temperature gauge AT20D transformer (except S.E.) Draft hood (for G-23-DPG only shipped in separate carton) Note: Shipped with all controls, main burners and manifold controls factory installed and wired. Manual main gas and pilot gas shut-off valves (when required) and relief valve shipped in accessory box fastened inside boiler crate. Optional equipment Self-energizing controls (consist of VS81 Series gas valve; Q313 Thermo pile Generator and limit control as noted above) available when specified on order......................................................................................................no charge Natural to Propane gas conversion kits. Order boiler with "ribbon burners" and "Natural to Propane conversion kit": Trade Price $5.70 Note: in areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above. Thermostats for 24V. and S.E. control systems are available. For prices see page 35. Zone valve packages are available for water boilers. For details and prices, see page 34. Page 6 02406 ^AMERICAN olSTANDARD HYDRONIC HEATING boilers-gas fired WATER AND STEAM G-2 NON-PACKAGED ALL-PURPOSE GAS BOILERS As a water boiler, this model is available with or without tankless coil for domestic water needs. With steam trim it is a top notch modernization item. Two jacket stylesFlush or Deluxe-this line is available in nine (9) sizes with factory assembled sections Featuring the patented "Eliminaire" cast-in air separator in left end section, the boiler is tested and equipped for 30 lbs. water working pressure, 15 lbs. steam and is regularly furnished for 115 volt, 60 cycle power supply with 24 volt control sys tem. Self-energizing controls are available without extra charge. Ratings shown are for installation at sea level and up to 2,000 feet. WATER--Natural and Propane Gases--(Available with factory installed Tankless heater, see options, pages 15 & 16) --100% shut-off. boiler number A.G-A. Input Mbh A.GA. output Mbh net l=B = R rating Mbh net rating sq ft water Trade Price with standard equipment less thermostat flush jacket deluxe jacket approx. shipping walght chimney size inside diam. in. height feet G-23--W G-24-*W(T) G-25-*W(T) G-26-*W(T) G-27-*W(T) G-28-*W(T) G-29-*W(T) G-210-WCO G-211-*W(T) 60 90 120 150 180 210 240 270 300 48 41.7 278 $242.00 $258.00 72 62.6 417 307.00 323.00 96 83.5 556 366.00 382.00 120 104.3 695 420.00 436.00 144 125.2 834 466.00 482.00 168 146.1 974 520.00 536.00 192 167.0 1113 216 187.8 1252 240 208.7 1391 573.00 620.00 673.00 589.00 636.00 689.00 295 353 426 500 566 630 699 790 863 4 5 5 6 6 7 7 7 7 10 10 10 10 10 10 10 10 10 Substitute letter`T*'for flush or "D" for deluxe jacket. Suffix "T" denotes forced circulation boiler equipped with factory Installed tankless heater (see page 16 for added charge). STEAM--Natural and Propane Gases--100% shut-off. boiler number A.G.A. input Mbh A.G.A. output Mbh net l=B=R rating Mbh sq ft W' Trade Price with standard equipment lest thermostat flush jacket deluxe jacket approx. shipping weight chimney size Inside diam. in. height feet G-23--S G-24--S G-25--S 60 48 36 90 72 54 120 96 72 G-26--S G-27--S G-28--S 150 120 90 180 144 108 210 168 126 G-29--S 240 192 144 G-210--S 270 216 162 G-211--S 300 240 180 Substitute letter "F" for flush or "D" for deluxe jacket. 150 225 300 375 450 525 600 675 750 $285.00 351.00 409.00 463.00 509.00 564.00 616.00 663.00 716.00 $301.00 367.00 425.00 479.00 525.00 580.00 632.00 679.00 732.00 310 368 442 517 583 648 718 809 883 4 5 5 6 6 7 7 7 7 10 10 10 10 10 10 10 10 10 Standard Equipment V81 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat. Ordering examples: 1. Non-packaged all-purpose water boiler with standard equipment and flush jacket; 1 G-27-FW boiler Nat. gas, 1000 Btu, .6 sg. 2. Non-packaged all-purpose water boiler with optional equipment and deluxe jacket: 1 G-210-DWT boiler with (1) No. 232 tankless heater installed Nat. gas, 1000 Btu, .6 sg For Other Optional Equipment, See page 15. AT20D Transformer (except S.E.) Drain valve Draft hood (for G-23-D and all flush jack eted boilers shipped in separate carton) Additional standard equipment Water boilers ASME relief valve Pressure and temperature gauge L4080 (24V. and S.E.) Aquastat limit control Note: Zone valve packages are available for water boilers. For details and prices, see page 34. Steam boilers ASME safety valve Steam gauge PA404A (24V. and S.E.) pressure limit control No. 67-GAR (24V. and S.E.) low water cut-off Gauge glass with trimmings Floor pan and radiation shield Optional Equipment Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit": G-23 thru G-27 G-28 thru G-211 ^ Trade Price $5.70 'wr Trade Price $7.70 yf See page 56 Page 7 HH-ll BOILERS--GAS FIRED WATER AND STEAM rSl AMERICAN ca STANDARD HYDRONIC HEATING G-40 GAS BOILERS This fine boiler is ideal for installation in larger residences, small apartments, and commercial buildings. Has deluxe jacket with built-in draft hood. Note that tankless heaters are available for both steam and water. Features "Ehmi naire" cast in the left end section. Regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system. Self-energizing controls optional. Tested and equipped for 50 lbs. water working pressure with 80 lbs. water pressure optional at extra cost. Tested ratings shown are for installation at sea level and up to 2,000 ft. WATER -- For Natural and Propane Oases -- 100% Shut-Off. For Built-In Water Heaters, see page 16. boiler number G-403-W G-404-W G-405-W G-4Q6-W G-407-W G-40B-W G-409-W G-4010-W G-4011-W G-4012-W G-4013-W G-4014-W AGA input Mbh 150 2 25 300 375 450 525 800 675 750 825 900 975 A.G.A output Mbh 120 180 240 300 360 420 480 540 600 660 720 780 net 1 =B=R rating Mbh 104 3 156 5 208 7 260 9 313 0 365 8 417 4 469.6 521 8 574 0 626 2 678.4 net rating *q. ft water 695 1043 1391 1739 2006 2434 2782 3130 3479 3827 4175 4523 Trade Price with standard equipment less thermostat $ 404.00 513.00 622.00 737.00 652.00 939.00 1048.00 1158.00 1268.00 1380.00 1490.00 1598.00 approx. shipping weight 827 998 1162 1349 1517 1686 1856 2026 2195 2364 2533 2702 chimney size inside diam. in 8 B 8 10 10 10 10 12 12 12 12 15 height feet 15 15 15 15 15 15 15 15 15 15 15 15 STEAM -- For Natural and Propane Gases -- 100% Shut-Off. For Built-In Water Heaters, see page 16. boiler number G-4Q3-S G-404-S G-40S-S G-406-S G-407-S G-4Q8-S G-409-S G-401Q-S G-4011-S G-4012-S G-4013-S G-4014-S A.G.A. input Mbh 150 225 300 375 450 525 600 675 750625 900 975 A.G.A output Mbh 120 180 240 300 360 420 480 540 600 660 720 780 net 1 = B = R rating Mbh 90 0 135 0 180.0 225 1 270.1 315.1 360.1 405.1 450.0 495.2 540.0 585.1 sq. ft. 375 563 750 936 1125 1313 1500 1688 1875 2063 2250 2438 Trade Price with standard equipment less thermostat $ 447.00 556.00 665.00 760.00 895.00 962.00 109100 1201.00 1311.00 1423.00 1533.00 1641.00 approx. shipping weight 858 1027 1195 1370 1544 1713 1880 2050 2219 2388 2557 2726 chimney site inside diam. in. 8 8 8 10 10 10 10 12 12 12 12 IS height feet 15 15 15 15 15 15 15 15 15 15 15 15 Ordering Examples: 1. Water boiler with standard equipment: 1 G-406-W boiler Nat. gas, 1000 Btu, .6 sg. 2. Steam boiler with optional equipment: 1 G-409-ST 1 No. 226 tankless heater with controls Nat. gas, 1000 Btu, .6 sg. Standard equipment V-8139A Combination Gas Valve: G-403 and G-404 for Natural Gas V-8139B Combination Gas Valve: G-403 thru G-407 for Propane Gas G-50AAG Combination Gas Valve: G405 and G-406 for Natural Gas V-88A Diaphragm Gas Valve: G-407 thru G-4014 for Natural Gas G-408 thru G-4014 for Propane Gas Gas pressure regulator (except propane gas) Manual main gas shut-off valve Manual pilot gas shut-off valve where diaphragm gas valve is standard. AT30 Transformer (except S.E.) L62GB (24V.) or CS591A (S.E.) combination pilot switch and valve with auxiliary pilot valves (100% shut-off) Drain valve Water heater opening cover plates Additional standard equipment Water ASME relief valve Pressure and temperature gauge L4006A (24V. and S.E.) immersion limit control Zone valve packages are available for water boilers. For details and prices, see page 34. Steam ASME safety valve Steam gauge PA404A (24V. and S.E.) pressure limit control Gauge glass with trimmings No. 67-GAR (24V. and S.E.) low water cut-off Optional equipment (See pages 15, 16 and 17) HH-11 See page 56 Page 8 02408 _ AMERICAN S STANDARD HYDRONIC HEATING PACKAGED BOILER GAS FIRED WATER GWP PACKAGED GAS BOILER (Single Boiler Installation) The GWP boiler package offers a ready-to-install heating plant for large residences, small apartment and commercial buildings. Designed for forced circulation only, the GWP includes factory mounted and wired controls. Burners are installed and deluxe jacket is factory mounted. Relief valve, temperature-pressure gauge and draft hood are shipped separately. The patented "Eliminaire" is also included. Boiler is tested and equipped for 50 lbs. working pressure and regularly furnished foi 115 volt, 60 cycle power supply with 24 volt control system. Self-energizing controls arc available at no additional cost. Ratings shown are for installations at sea level and up to 2000 ft. WATER--100% shut-off--Natural and Propane Gas packaged boiler number* GWP-5 GWP-6 GWP-7 A.C.A. input Mbh 264 330 396 _ A.G.A. output Mbh 211.2 264,0 316.8 not 1 = 8=8 Mbh 183.5 229.6 275.7 chimney tut Intide die. >n. 7 height feet 15 8 15 8 15 appro* ihippmg weight 613 716 823 Trod* frtcc with standard equipment lets Ihermettat $ 430.00 520.00 620.00 Standard equipment Combination automatic gas valve Gas pressure regulator (except propane) Manual main gas shut-off valve Manual pilot gas shut-off valve AT-20D transformer (except S.E.) Pilot Valve & Switch Drain Valve ASME Relief Valve Pressure-Temperature Gauge Deluxe Jacket L4080D Immersion Limit Control Draft Hood Drilled Port Burners are standard for natural gas. Ribbon Burners are standard for propane gas and optional for nat ural gas. Optional equipment Self Energizing controls No Price Add Zone Valve Packages are available (for details and prices see page 34) Add suffix "R" to model number if ribbon burners are desired. Example: GWP-5R Optional constant circulation (24 volt) L4081B limit and reverse acting circulator controls instead of L4080 limit control. Added Trade Price $10.30 See page 56 Page 9 HH-11 MODULAR GAS FIRED WATER BOILER ^AMERICAN Si STANDARD HYDRONIC HEATING GWM GAS MODULAR BOILER HOOK-UP (Modular Boiler Installations) The GWM Modular Boiler Hook-up is a combination or multiple of five, six or seven section GWM boiler modules. Each module has factory assembled sections with burners, gas manifold, and automatic gas valve mounted. Deluxe jacket, controls and draft hood are shipped separately. The patented "Eliminaire" is a standard feature. Factory fabricated water manifolds are available as listed under optional equipment. GWM Modular Boilers are furnished for 115 volt, 60 cycle power supply with 24 volt control system. (Self-energizing controls are not available). Boilers are tested and equipped for 50 PSIG working pressure. Indicated ratings are for installation at sea level and up to 2000 ft. elevation. GWM BOILER MODULES -- Natural and Propane Gas: 100% Shut-Off. module boiler number* GWM-5 GWM-6 GWM-7 AG.A input Mbh 264 330 396 A.G.A output Mbh 211.2 264.0 316.8 net l=ft = R rating Mbh 183.5 229.6 275.7 opprox. shipping woightt lbs. 629 735 846 Trod* Price with standard equipment less thermostat $418.00 508.00 608.00 Standard equipment Combination automatic Gas Valve Gas pressure regulator (except propane) Manual Main Gas shut-off valve Manual pilot gas shut-off valve Transformer Belay Pilot valve and switch Drain Valve ASME Relief Valve(s) as required Pressure-Temperature Gauge as required Deluxe Jacket L4080D Immersion Limit Control Draft Hood Drilled Port Burners are standard for natural gas. Ribbon burners are standard for propane gas and optional for nat ural gas. Optional equipment 1. Factory fabricated Water Manifold for Primary/Secondary circulation. Includes interconnecting supply piping (Boiler to manifold). Inter connecting return piping and circulator not included. Trade Price add per module $41.00 2. Factory fabricated Water Manifold for Parallel Boiler Hook-up. In cludes interconnecting supply and return piping (boiler to manifold). ................................................................Trade Price add per module $82.00 3. Electronic Control Panel Systems-- For application and details, contact American-Standard. Add suffix "R" to model number if ribbon burners are desired. HH-11 See page 56 Page 10 a 02410 (AMERICAN ei STANDARD HYDRONIC HEATING MODULAR GAS FIRED WATER BOILER GWM GAS MODULAR BOILER HOOK-UP (Modular Boiler Installations) The following boiler units in 66,000 BTU input increments are achieved with module boiler combinations: MODULAR BOILER HOOK-UPS -- Natural and Propane Gas - 100% Shut-Off. unit number GWM-528 GWM-594 GWM-660 GWM-726 GWM-792 GWM-858 GWM-924 GWM-990 GWM-1056 GWM-1122 GWM-1188 GWM-1254 GWM-1320 GWM-1386 GWM-1452 GWM-1518 GWM-1584 GWM-1650 GWM-1716 GWM-1782 GWM-1848 GWM-1914 GWM-1980 GWM-2046 GWM-2112 GWM-2178 GWM-2244 GWM-2310 GWM-2376 GWM-2442 GWM-2508 GWM-2574 GWM-2640 GWM-2706 GWM-2772 GWM-2838 GWM-2904 GWM-2970 GWM-3036 GWM-3102 GWM-3168 and upward modular competition 5 ictl. 4 ioct. 7 tact. 2 1 1_ 2- __ 1 __ 1 2 2 1- 2 __ 3_ -2 12 __ 3 3- 4 __ _3 -22 _i3 __ __ 4 - 5- 4 __ 3 -2 _ __ -5 2 3 4 5 1 _ 4 3 2 3 -24 5 __ 6 52 _ 4 3 -2 _ __ _ -5 3 4 s 6 7 3 _4 _3 -2 __ ~" 4 5 6 7 8 grot* input Mbh 528 594 660 726 792 858 924 990 1056 1122 1188 1254 1320 1386 1452 1518 1584 1650 1716 1782 1848 1914 1980 2046 2112 2178 2244 2310 2376 2442 2508 2574 2640 2706 2772 2838 2904 2970 3036 3102 3168 grots output Mbh 422.4 475.2 526.0 580.8 633 6 686.4 739.2 792.0 844.8 897.6 950.4 1003.2 1056.0 1108.8 1161.6 1214.4 1267.2 1320.0 1372.B 1425.6 1478.4 1531.2 1584.0 1636.0 1689.6 1742.4 1795.2 1848.0 1900.8 1953.6 2006.4 2059.2 2112.0 2164.8 2217.6 2270.4 2323.2 2376.0 2428.8 2481.6 2534.4 not output Mbh 367.0 413.9 459.1 504.3 551.3 596.5 643.5 688.7 733.9 780.9 826.1 873.0 918.3 963.5 1010.4 1055.7 1102.6 1147.8 1193.0 1240.0 1285.2 1332.2 1376.4 1422.6 1467.8 1516.5 1561.7 1607.0 1652.2 1697.4 1746.1 1791.3 1836.5 1881.7 1927.0 1975.7 2020.9 2066.1 2111.3 2156.5 2205.2 approx shipping weight 1258 1364 1470 1581 1692 1993 2099 2205 2316 2427 2538 2834 2940 3051 3162 3273 3384 3675 3786 3897 4008 4119 4230 4521 4632 4743 4854 4965 5076 5367 5478 5589 5700 5811 5922 6213 6324 6435 6546 6657 6768 Modular Operating Control Package Options 1. Four stage immersion type operating control, (one required for up to 4 modules) ...................................... Trade price add per control $70.00 2. Immersion type operating controls with individual outdoor resets. Trade price add per module $47.00 3. Eight stage boiler sequencing control package with outdoor reset, (one required for up to 8 modules) Trade price add per control $270.00 Trade Price with standard equipment S 820.00 910.00 1000.00 1100.00 1200.00 1312.00 1402.00 1492.00 1592.00 1692.00 1792.00 1894.00 1984.00 2084.00 2184.00 2284.00 2384.00 2492.00 2592.00 2692.00 2792.00 2892.00 2992.00 3084.00 3184.00 3284.00 3384.00 3484.00 3584.00 3676.00 3776.00 3876.00 3976.00 4076.00 4176.00 4266.00 4368.00 4468.00 4568.00 4668.00 4768.00 'W See page 56 Page 11 HH-11 02411 non-packaged gas fired WATER AMERICAN baSTANDARD HYDRONIC HEATING GW NON-PACKAGED GAS WATER (Single or Modular Boiler Installations) The GW Boiler is a non-packaged boiler available in three sizes designed for forced circulation only. Factory assembled sections are standard with jackets, burners and manifolds shipped separately. Included for field installation are a relief valve, tempera ture-pressure gauge, and draft hood. The patented "Eliminaire" is also included. Installed individually or in modular groups, the GW boiler is ideal for renovation work as well as new construction. Each boiler is tested and equipped for 50 PSIG working pressure and regularly fur nished for 115 volt, 60 cycle power supply with 24 volt controls. Self-energizing controls are available at no additional cost. Ratings shown are for installations at sea level and up to 2000 ft. elevation. INDIVIDUAL BOILERS -- WATER -- 100% shut-off -- Natural and Propane Gas chimney tile boilei niwnber* A G A. input Mbh A.G.A. output Mbh not l =6 = R Mbh Inside dio in. height 4eet GW-8 GW-9 GW-10 462 528 594 369.4 422.4 475.2 321.7 367.0 413.9 9 10 10 15 15 15 approx shipping weight 938 1052 1177 Trade Price with standard equipment lest thermestot $ 670.00 725.00 780.00 MODULAR BOILERS -- WATER - 100% shut-off -- Natural and Propane Gas unit numbe* GW-924 GW-990 GW-10S6 GW-1122 GW-1188 GW-1386 GW-14S2 GW-1518 GW-1584 GW-1650 GW-1716 GW-1782 GW-1848 GW-1914 GW-1980 GW-2046 modular composition ted 9 ted 10 sect. 200 1 10 --0 2 0 01 1 00 2 300 210 1 20 030 02 1 01 2 003 400 310 220 1 30 III 924 990 1056 1122 1188 1386 1452 1518 1584 1650 1716 1782 1848 1914 1980 2046 gross output Mbh 739 792 845 879 950 1108 1162 1214 1267 1320 1373 1426 1478 1531 1584 1637 net output Mbh 644 689 734 781 826 964 1010 1056 1103 1148 1193 1240 1285 1332 1376 1423 approx thrppmg weights 1876 1990 2104 2229 2354 2814 2928 3042 3156 3281 3406 3531 3752 3866 3980 4094 Trade Price with standard equipment less thermoitot $ 1340.00 1395.00 1450.00 1505.00 1560.00 2010.00 2065.00 2120.00 2175.00 2230.00 2285.00 2340.00 2680.00 2735.00 2790.00 2845.00 Standard equipment Combination automatic gas valve Gas pressure regulator (except propane) Manual gas shut-off valve Manual pilot gas shut-off valve AT-20D Transformer (except SE) Pilot Valve and Switch Drain Valve ASME Relief Valve Pressure-Temperature Gauge L-4080D Immersion Limit Control Deluxe Jacket Draft Hood Drilled Port Burners are standard for natural gas. Ribbon Burners are standard for propane gas and optional at no price add for natural gas. Optional equipment Self-energizing controls ................................. .......... no price add Electronic Control Panel System -- For application and details, contact American-Standard. Modular Operating Control Package Options 1. Four stage immersion type operating control (one required for up to 4 modules) ..................................... Trade Price add per control $70.00 2. Immersion type operating controls with individual outdoor resets (one required for each module)..............Trade Price add per module $47.00 3. Eight stage boiler sequencing control package with outdoor reset (one required for up to 8 modules) . Trade Price add per control $270.00 Add suffix "R" to model number if ribbon burners are desired. HH-11 See page 56 Page 12 02412 AMERICAN cd STANDARD HYDRONIC HEATING BOILERS-GAS FIRED WATER G-10 GAS BOILERS A compact, high capacity boiler for commercial and industrial application. Features single com bustion chamber to simplify wiring and controls. Built-in heaters available for storage tank or tankless application. Tested and equipped for 60 lbs. water working pressure with 80 lbs. water working pressure optional at extra cost. Integral draft hood located at rear of boiler with optional top outlet (except G-1010) available at no extra charge. WATER -- Natural Gas -- 100% Shut-Off. For Built-In Water Heaters, see page 16. boiler number A.G.A. input Mbh A.G.A. output Mbh * net l = B = R rating Mbh 1=B=R piping and pick-up factor a rTrade Price net rating sq. ft. water with standard equipment less thermostat approx shipping weight chimney size inside diam. in. ht. ft G-105-W G-106-W G-107-W G-10B-W G-109-W G-1010-W G-1011-W G-1012-W G-1013-W G-1014-W G-1015-W G-1016-W G-1017-W G-1018-W G-1019-W G-1020-W G-1021-W G-1022-W G-1023-W G-1024-W G-1025-W G-1026-W G-1027-W G-1028-W G-1029-W G-1030-W G-1031-W G-1032-W G-1033-W 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 640 800 960 1120 1280 1440 1600 1760 1920 2080 2240 2400 2560 2720 2880 3040 3200 3360 3520 3680 3840 4000 4160 4320 4480 4640 4800 4960 5120 556 5 695.7 834.8 973.9 1113.0 1252.2 1391.3 1530.4 1669.6 1808.7 1947.8 2087.0 2226.1 2365.2 2504.3 2643.5 2782.6 2921.7 3060.9 3200.0 3339.1 3478.3 3617.4 3756.5 3895.7 4034.8 4173.9 4313.0 4452.2 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 3710 4638 5565 6493 7420 8348 9275 10203 11131 12058 12985 13913 14841 15768 16695 17623 18551 19478 20406 21333 22261 23189 24116 25043 25971 26899 27826 28753 29080 $1260.00 1535.00 1807.00 2097.00 2343.00 2593.00 2856.00 3188.00 3561.00 3870.00 4112.00 4366.00 4632.00 4909.00 5198.00 5441.00 5729.00 5983.00 6272.00 6537.00 6780.00 7069.00 7346.00 7543.00 7739.00 8039.00 8282.00 8524.00 8776.00 2905 3443 3990 4536 5093 5657 6231 6646 7159 7679 8252 8746 9244 9753 10265 10801 11278 11841 12351 12860 13391 13864 14376 14674 15378 15868 16391 16896 17405 14 14 14 16 16 18 18 20 20 22 22 22 22 24 24 24 26 26 26 26 28 28 28 28 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 * The net l = B = R ratings shown are based on the factors shown in the piping and pickup column American Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements. Standard equipment V88A gas valve(s) Drain valve Gas pressure regulator (except Draft hood Propane gas) L62GB combination pilot switch and Manual main gas shut-off valve valve 817F-11 pilot valves Manual pilot gas shut-off valve Pressure and temperature gauge AT20D Transformer L4006A immersion limit control Ribbon type main burners Optional equipment: See pages 15,16 and 17 ASME relief valve Ordering Examples: 1. Water boiiar. 1 G1013-W boiler Nat gas, 1000 Btu. 6 sg "W See page 56 G-10 GAS BOILERS -- WATER for Propane Gas Propane Gas Ratings are determined by reducing the Natural ratings above by 10%. Example: G-105-W A.G.A. input 800 less 10%=720 Mbh Input for Propane Gas. Detailed Propane Gas ratings are shown in current Technical Literature Trade Prices. Chimney Sizes and shipping weights remain the same as shown above Page 13 HH-11 02413 BOILERS-GAS FIRED STEAM ^AMERICAN ksiSTANDARD HTDRONIC HEATING G 10 GAS BOILERS -- This steam boiler is ideal for new work or modernization. Features a deluxe jacket which may be assembled to the boiler after piping has been installed. Integral draft hood locat ed at rear of boiler with optional top outlet (except G1010) available at no extra charge. This boiler is regularly furnished for 116 volt, 60 cycle power supply with 24 volt con trol system. Ratings shown are for installation at sea level and uo to 2.000 ft. STEAM -- For Natural Gas -- 100% Shut-Off. For Built-In Water Heaters (G-105S thru G 1014S only) See page 16. number A.G.A. input Mbh A.G.A. output Mbh a net J=B - R rating Mbh sq. ft. |r=0 = R piping and pick-up factor a ''Trade Price with standard equipment less thermostat approi shipping weight chimney size inside dtam. in. ht. ft. G-105-S G-106-S G-107-S G-108-S G-109-S G-IOtO-S G-1011-S G-1012-S G-1013-S G-1014-S G-1015-S G-1016-S G-1C17-S G-1018-S G-1019-S G-1020-S G-1021-S G-1022-S G-1023-S G-1024-S G-1025-S G-1026-S G-1027-S G-102S-S G-1029-S G-1030-S G-1031-S G-1032-S G-1033-S 800 1000 1200 640 800 960 1400 1600 1800 1120 1280 1440 2000 2200 2400 1600 1760 1920 2600 2800 3000 2080 2240 2400 3200 3400 3600 2560 2720 2880 3800 4000 4200 - 3040 3200 3360 4400 4600 4800 3520 3680 3840 5000 5200 5400 4000 4160 4320 5600 5800 6000 4480 4640 4800 6200 6400 4960 5120 480.1 600.1 720.2 840.2 962.4 1095.1 1227.9 1361.2 1489.5 1614.9 1739.1 1863.4 1987.6 2111.8 2236.0 2360.2 2484.5 2608.7 2732.9 2857.1 2981.4 3105.6 3229.8 3354.0 3478.3 3602.5 3726.7 3850.9 3975.2 2000 2501 3001 3501 4010 4563 5116 5672 6206 6729 7246 7764 8282 8799 9317 9834 10352 10870 11387 11905 12422 12940 13458 13975 14493 15010 15528 16046 16563 1.333 1.333 1.333 1.333 1.330 1.315 1.303 1.293 1.289 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 $1304.00 1579.00 1851.00 2141.00 2387.00 2637.00 2900.00 3232.00 3625.00 3914.00 4156.00 4410.00 4676.00 4953.00 5242.00 5485.00 5773.00 6027.00 6316.00 6581.00 6824.00 7113.00 7390.00 7587.00 7783.00 8083.00 8326.00 8568.00 6822.00 2910 3453 4000 4548 5103 5667 6241 6646 7159 7679 8252 8748 9244 9753 10265 10801 11278 11841 12351 12860 13391 13884 14376 14874 15378 15868 16391 16898 17405 14 14 14 16 16 18 18 20 20 22 22 22 22 24 24 24 26 26 26 26 28 28 28 28 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 a The net l=B=R rating* shown are based on the factors shown in the piping and pickup column American Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements. Standard equipment Ij '[ !l HH-11 See page 56 V88A gas valve(s) Gas pressure regulator (except propane gas) Manual main gas shut-off valve Manual pilot gas shut-off valve AT30 Transformer ASME safety valve Steam gauge Ribbon type main burners Ordering Examples: Steam boiler with standard equipment 1 G1015-S boiler Nat (as, 1000 8tu, .65 sg Drain valve Draft hood 853-1 combination pilot switch and valve 817F-11 pilot valves PA404A pressure limit control Gauge glass with trimmings No 67AR Low Water cut-off Optional equipment (See pages 15,16 and 17) G-10 GAS BOILERS -- STEAM for Propane Gas Propane Gas Ratings are determined by reducing the Natural Gas ratings above by 10%. Example G-105-S A.G.A. Input 800 less 10%=720 Mbh Input for Propane Gas. Detailed Propane Gas ratings are shown in current G-10 Technical Literature. Trade'Prices. Chimney Sizes and shipping weights remain the same as shown above. Page 14 < < 02414 ^AMERICAN izi STANDARD HYDRONIC HEATING MISCELLANEOUS OPTIONS GAS BOILERS MISCELLANEOUS OPTIONS - NON-PACKAGED GAS BOILERS G-2, G-40 AND G-10 BOILERS: Thermostats are available at Trade Prices shown on page 35. Side Outlet ASME Steam Safety Valve may be substituted at no additional charge if specified on order to meet local code requirements. "IS" Equipment: boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. L4006A immer sion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on page 35. This control operates gas valves on boiler electrically as required. Shipping weights of gas boilers for hot water supply are same as shown for regular gas boilers. Low water cut-offs for water boilers: No. 63 cut-off for water working pressures of 50 lbs., or less, available when speci fied at additional Trade Price of (42.75 No. 150 cut-off for water working pressures in excess of 50 lbs. available when specified at additional Trade Price of $64.25 G-2 BOILERS: "DW" (Direct Water) equipment: In addition to water boiler standard equipment, page 7, includes pressure gauge, 80 lb. ASME relief valve, L4006A Aquastat for storage tank, tank thermometer, name and rating plate for 80 lbs. water work ing pressure. Specify boiler with "DW" equipment and add $16.50to Trade Price of All-Purpose Water Boiler, page 7. Floor shield for combustible flooring. Add suffix letter "CM to boiler number and add to Trade Price of boiler $3.28 G-2 ANO G-40 80ILERS: Self-energizing control: All size G-2 and G-40 for propane gas. All G-2 and G-40 thru G-4010 for natural gas. Equip ment includes: S.E. gas valve as required, Q313A Thermo pile Generator and a L4006 S.E. limit control (water boilers less heater) or an L8124B Triple Aquastat Relay (water boilers with heater) or a PA404A Pressuretrol (steam boilers less heater). For steam boilers with heater L4006A S.E. immersion operating control will be furnished in addi tion to the Pressuretrol. Furnished at no additional charge when specified on order. Special thermostat required, for Trade Price, see page 35. No. 101-24V electric water feeder can be added to the No. 67-GAR low water cut-off regularly furnished with steam boilers to provide low water cut-off and feeder combi nation at additional Trade Price of $55.81 Zone circulator control for water boiler with tankless heater and combination immersion control-relay: use one T822D thermostat and one R845A relay for second and/or third zone. For Trade Prices, see page 35. Water flow regulators sized for tankless heater involved will be furnished with heater when specified on order to meet local Utility requirement at Trade Price additional charge per heater of $3.25 G-40 AND G-10 BOILERS: No. 47-2 boiler water feeder and cut-off combination is avail able instead of the 67-AR regularly furnished with G-403 through G-108 steam boilers at additional Trade Price of ....................................................................................... $41.60 No. 51-2 boiler water feeder and cut-off available instead of No. 67-AR regularly furnished with G-109 thru G-1031 steam boilers at additional Trade Price of $62.70 Try-cocks and tappings: if desired for steam boiler to meet local code specify on order and add to Trade Price of steam boiler . $4.25 Boilers tested for 80 lbs. water working pressure: available when specified on order. Add per section to Trade Price of water boiler $8.00 per section G-40 BOILERS: Boilers with Tankless Heaters: water (for forced circulation) and steam boilers can be furnished with tankless heaters. Heaters are limited to boiler sizes as shown in ratings table on next page. Specify heater and add suffix "T" to boiler number. Factory assembled sections: G-403 through G-4014 can be shipped with sections factory assembled when specified on order. Add $11.00 per section to Trade Price of boiler. G-10 BOILERS: Pilot filters for G-10 for natural and mixed gases available at no additional charge when specified on order to meet local utility codes. G-10 Steam Boiler external water heater tappings in cover plates: maximum size Specify number of cover plates with tapping. Added Trade Price per tapping $4.25 G-10 Right End Section Steam Trim Tappings for pressure gauge and water column fittings or for auxiliary controls furnished as standard equipment at no additional charge. Modulating gas valve: the G-10 boiler can be specified with the V6034A/V5034A gas valve for Hi-Lo-off operation. This valve permits adjustment of the Lo-fire operation down to a minimum of 20% of the boiler input. Operation of the valve should be controlled by a SPDT operating control. If desired, specify on order and add to the Trade Price of the boiler with regular equipment the following Trade Prices. G-105 thru 1018................................................................$161.50 G-1019 thru 1033 . $205.00 Top outlet drafthood (natural gas only); available (ex cept G1010) at no extra charge when specified on order. See current literature for chimney recommendations. Factory assembled sections: Available thru G-1011. Specify on order. Allow 3 week lead time. Added Trade Price per section $21.00 'W See page 56 Page 15 HH-11 02415 AMERICAN calSTANDARD HYDRONIC HEATING tankless heaters-gas fired WATER AND STEAM G-2 TANKLESS HEATERS G 2 NONPACKAGED ALL-PURPOSE BOILER: Factory installed tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation. See table below for I=W = H ratings and applicable boiler size. Specify heater, add suffix "T" to boiler number and "factory installed." Add Trade Price shown. Ratings boiler number A.G.A. Input Btu/hr. heater 218 | = W=sH Rating heater 222 heater 226 G-24 90.000 2`/z -- -- G-25 120.000 --3 -- G-26 150,000 -- 3 Vi -- G-27 180,000 -- 3>/2 4 G-28 210,000 -- 3% 4'/i G-29 240,000 -- 3V2 4 Vi G-210 270.000 -- 3V2 4 Vi G-211 300,000 -- 3>/2 4 y2 G-2 PACKAGED AND NON-PACKAGEDALL-PURPOSE BOILERS: Tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation I = W = H tankless heaters can be installed in opening used for gravity tapping flange cover. See table for I=W = H ratings and applicable boiler size Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below. Trade Prices heater 232 -- ---- heater number 218 222 226 232 factory Installed $45.00 49.00 61.00 69.00 sold separate $24.00 28.00 40.00 48.00 -- -- * L8124E for 24 Volt or L8124B for SE. Triple Aquastat Relay furnished with 4`/2 heater (packed in trim box). 4 V* Water flow regulator. Specify on order. Added 5 Trade Price $3.25 G-40 TANKLESS HEATERS -- STEAM OR FORCED WATER BOILERS Ratings (Gallons per minute*) Trade Prices Boiler HEATER 218 HEATER 222 HEATER 226 HEATER 232 HEATER 445 HEATER 460 Steam Water Steam Water Steam Water Steam Water Steam Water Steam Water G-403 3 G-404 3 V; 4 4 V; G-405 3 Vi 4 4 V; 5'/j 6 ---- --- -- G-40* G-407 3 Vi .,3% 4 4 V? 5 Vi 6 ---- ---- 4 i'A 6 evi 7 7 V; -- -- -- -- G-408 G-409 3% 3% 4 4 4 Vi 6 6>/i 7Vi 8 BVi 4 4 '/i 6 6 Vi m 8 ZVi 9 -- -- G-4010 G4011 G-4012 3W 3% m 4 4 4 4 4'/} 4 4'/* 4 4'/, 6 6Vr 7 % 8 m 6 6 V; 8 6 6 Vi 7Vi 8 8% -- 11 12 G 4013 3Vi 4 4 4 V; 6 6 Vi 7Vi B 8 Vi 13 G-4014 3 Vi 4 4 4 Vi 6 6 Vi 7% 8 8'A 13 Gallons of water per minute aised from 40*F lo 140*F with 200'F boiler water temperature. -- -- -- -- -- 12 13 14 Vj 15'A G-10 BOILERS --TANKLESS OR TANK TYPE HEATER No. 1023 heater is available in any quantity. Specify number required. Trade Price each $33.50 HEATER NO. HEATER WITH CONTROLS Water Steam(') HEATER ONLY Water or Steam 218 344.00 338.00 324.00 222 46.00 42.00 28.00 226 58.00 54.00 40.00 232 66.00 62.00 48.00 445 79.00 75.00 61.00 460 85.00 81.00 67.00 Tankless heaters with controls for water boilers: L8124E combination immersion control-relay packed in trim box in place of standard limit control. Tankless heaters with controls for steam boilers: L4006A immersion operating control packed in trim box in addition to PA404A pressure limit control. Water flow regulator. Specify on order. Added Trade Price $3.25 (') Additional L4006A operating control re quired for steam boiler-heater combina tions shown shaded. Add to above heater w/control Trade Price $14.05 The ratings table on this page shows the ratings attained if more than one heater is connected in parallel. Copper pipe manifolds, factory assembled for multiple heater parallel hookup, shipped in boxes of 2 manifold assemblies per box, when specified with heaters, are avail able at the following charges: Manifold Assembly Two Heater i Three Heater Four Heater Trade Price S 7.25 11.00 14.00 All G-10 water boilers and sizes G-106S thru G-1014S steam boilers can be provided with sections for insertion of heaters at no extra charge. When desired add suffix letter T to boiler number and specify the number of sections with heater openings. Cover plates to close unused water heater openings will be furnished only if specified on order at Trade Price each $4.50 When specified, the G-10 water boiler with heater can be provided with the combination L8124E in place of the L4006A limit control at the added Trade Price of $18.50 When No. 1023 heaters are used in steam boilers, the L4006A operating control will be required for installation in a heater tapping. See page 35 for Trade Price. When the No. 1023 heaters are used in a storage type domestic hot water system, the L4006A operating control will be required for insertion in a storage tank, see page 35" for the Trade Price. NO. 1023 HEATER RATINGS TANKLESS APPLICATION boiler number no. of tankless beaters Intermittent draw heater rating gpm @ 100 rrse pressure drop (with manifolds) PSI G-105 - G-1033 G-105 - G-1033 G-106 G-1033 G-108 G-1033 2 3 4 4 3/a 7 Vi 10 1 2 3/a NOTE: Heaters for Stasm Boilers available 5 thru 14 sections only 19 STORAGE TANK APPLICATION boiler number number of haaters continuous draw 100 rise (pm recovery capacity 100 rise fph boiler output required mbh G-105 - G-1033 G-105 - G-1033 G-106 - G-1033 G-108 - G-1033 G-1011 -G-1033 G-1023 - G-1033 G-1014 -G-1033 G-1016 G-1033 G-1018 - G-1033 G-1020 - G-1033 G-1022 - G-1033 G-1024 G-1033 1 2 3 4 5 6 7 8 9 10 11 12 4 240 200 7 420 350 10 600 500 13 780 650 16 960 800 19 1.140 950 22 1.320 1,100 25 1.500 1.250 28 1.680 1.400 31 1.860 1,550 34 2.060 1.700 37 2.220 1,850 NOTE: Heaters for Steam Boilers available 5 thru 14 sections only storage tank size (als. 500 500 500 1.000 1,000 1.000 1.500 1.500 1.500 2.000 2.000 2.000 HH-11 'W See page 56 Page 16 02416 AMERICAN iZiSTANDARD HYDRONIC HEATING f.m./f.i.a. special gas controls ELECTRONIC CONTROLS G-40 AND G-10 CONTROL OPTIONS G-40 AND G-10 BOILERS: F M or F.I.A equipment f I A requires special gas train PLUS F.I.A. electronic panel Special gas manifold control equipment that meets F.M. or F.I.A iniumiiLJN requirements are available at the Trade Price listed For actual F.I A. installations and before boiler installation, signed approval by F.I.A. inspector of both electronic control? and gas manifold control equipment being used should be obtained. Submittal data for F.M. or F.I.A. equipment is available from American-Standard. Electronic control systems are available as described and at the Trade Prices listed below Note: A low water cut-off for water boilers (50 lb. or 80 lb water working pressure) will be furnished as required and charged for at the prices shown for .No. G3 or No. 150 on page 15 F.M. & F.I.A. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY) ADD TO BOILER TRADE PRICE "W BOILER NUMBER F M () F 1 A.(:) G-403 thru G-4014 G-105 thru G-106 G-107 G-108 thru G-1011 G-1012 thru G-1017 G-1018 G-1019 thru G-1030 G-1031 thru G-1033 $ 84.00 73.00 85.00 75.00 122.00 164.00 170.00 218.00 $437.00 439.00 473.00 572.00 651.00 710.00 757.00 879.00 Ul F M gas control equipment includes two manual shut-oH valves, a test vent valve and one HO valve l;) F i a gas control equipment includes two manual snut-oft valves, Hi and LO pressure switches, two HO waives and a vent valve. G-40 AND G-10 ELECTRONIC CONTROL PANEL SYSTEMS (FOR 115 VOLT, 60 CYCLE 1 PHASE POWER ONLY) Panel System EPG-M: Provides manual ignition. 100r; safety shut-off with electronic^ supervision of pilots 1 to 3. Main burners and pilots are turned off on pilot failure. Continuous flame pilot operation. Equipment includes: one panel for each electronic pilot (Mam panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Baso valves and thermocouples and Q-179B electronic flame rod and pilot; RA890F protectorelay installed on panel; 3 ft. flame rod wire per pilot. Panel System EPG-ES: Provides electronic supervision of each pilot (1 to 3} and interrupted continuous burning pilot electronically turned off and electrically relighted on every cycle to achieve positive component check of relays and pilot system. Complete automatic operation of boiler. 100rr safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panels with 2-4 seconds response timing and alarm con tacts; minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot. Panel System EPG-E: Provides electronic supervision of each pilot (1 to 3) and intermittent electric ignition of all pilots. Complete automatic operation of boiler. lOO'T safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; Y-1040C pilot solenoid valves; RA890F protectorelay installed in panel with 2-4 seconds response timing and alarm contacts: minimum of 3 ft. of fiame rod wire and 3 ft. of ignition cable per pilot. Panel System EPG-M(FIA): Specifically designed to meet FI A requirements. Provides constant burning manually lighted electronically supervised pilots (1 to 3i. 100rr safety shut-off. Equipment includes: one pane) for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled: alarm bell, alarm silencing switch; purge timer, all factory assembled in master panel; RA 890F protectorelay installed in panel: Baso valves and thermocouples and Q-179B electronic flame rod pilot; 3 ft. flame rod wire per pilot. ADDITIONAL CHARGES-^Trade Price Specify on order type of system desired, as described above, and add charge for boiler size involved to Trade Price of boiler with regular equipment. PANEL SYSTEMS EPG-M boiler no. system no. G-403 thru G-4014 EPG-M1 G-105 thru G-1012 EPG-M1 G-1013 thru G-1023 EPG-M2 G-1024 thru G-1033 EPG-M3 added chare* (1) $206.00 206.00 396.00 594.00 PANEL SYSTEMS EPG-E boiler no. system no G-403 thru G-1014 EPG-E1 G-105 thru G-1012 EPG-E1 G-1013 thru G-1023 EPG-E2 G-1024 thru G-1033 EPG-E3 added charge (1) $228.00 228.00 420.00 630.00 PANEL SYSTEMS EPG-ES boiler no system no added charge (1} G-403 thru G-4014 EPG-ES1 $272.00 G-105 thru G-1012 EPG-ES1 272.00 G-1013 thru G-1023 EPG-ES2 464.00 G-1024 thru G-1033 EPG-ES3 675.00 PANEL SYSTEMS EPG-M(FIA) boiler no system no. added charge G-403 thru G-4014 EPG-MI(FIA) $376.00 G-105 thru G-1012 EPG-MI(FIA) 376.00 G-1013 thru G-1023 EPG-M2(FIA) 575.00 G-1024 thru G-1033 EPG-M3(FIA) 782.00 Flame Rod Wire: Trade Price per foot Ignition Cable: Trade Price per foot $0.40 0.85 `Trace once* apply to equipment when shipped v. ith hotler For field convers ons, price on application Note if purge timer is desired specify on orae' and add $62.0QTrade Price See page 56 Page 17 HH-ii 02417 packaged BOILER-BURNER UNITS WATER AMERICAN kS STANDARD HYDRONIC HEATING AP(T) PACKAGED BOILER-BURNER UNITS Designed and equipped with controls for forced circulation. Here's a competitively priced oil-fired cast iron boiler-burner unit just loaded with features that sell. Available with or without I-W-H rated tankless heater, this pack aged winner features the incomparable DH Burner and has the patented "Eliminaire" (cast-in air separator) that is exclusive with American-Standard Factory assembled, pre-wired and crated, this quality cast iron boiler at a budget price, is tested and equipped for 30 lbs. water working pressure. Motor and controls are regularly furnished for 115 volt, 60 cycle power supply. WATER packaged unit number cross l=B=R output Mbh l=B=R burner capacity gph tankless heater number l=W=H rating net I=B=R rating Mbh net rating sq ft water ''Trade Price with standard equipment approx. shipping weight chimney size Packaged units with factory installed tankless heater: With R8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control. APT-95 APT-130 APT-165 95 .95 218 2% 82.6 550 $491.00 496 8x8x15 130 1.25 222 3 V, 113.0 753 550.00 580 8x8x 15 165 1.60 230 3% 143.5 956 629.00 647 8x8x15 Packaged units less heater With L4080B Aquastat limit control, and separate R8184G light sensing primary control. AP-95 AP-130 AP-165 95 .95 130 1.25 165 1.60 82.6 113.0 143.5 550 $458.00 753 513.00 956 590.00 Nozzle sizes, gph. 60* solid, furnished with the above units: AP(T)-95. 0.90; AP(7)-130. 1.25; AP(T>-165. 1.50. Gallons of water per minute from 40F to I40*F with 200'F boiler water temperature 481 565 632 8x8x 15 8x8x15 8 x 8x 15 HH-ll See page 56 Standard equipment: Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. T822D thermostat. Light weight insulating fire brick combustion chamber. Nozzle. Draft regulator. ASME relief valve. Pressure and temperature gauge. 1%" circulator with piping. Wiring harness. Drain valve. Note: Units are shipped with flush jacket and with all electrical controls (except thermo stat), circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately. Draft regulator, relief valve and thermostat shipped inside boiler crate. Two-stage fuel unit is available for DH-5 oil burner. Specify on Order. Added Trade Price $6.15 Ordering Examples: 1. Packaged unit with heater 1 APT-130 2. Packaged unit less heater 1 AP-95 I Page 18 02418 ryi AMERICAN IS STANDARD HYDRONIC HEATING PACKAGED BOILER-BURNER UNITS WATER A-3 PACKAGED BOILER-BURNER UNITS Where quality, performance and packaged convenience are required, it's the A-3 all the way. Completely packaged and pre-wired, and crated to handle easily on that next job. Available with or without top performing tankless heater, the A-3 features the American-Standard built and backed DH Arcoflame oil burner for years of troublefree service. Wet base construction assures top perform ance; quality controls and accessories sell themselves. New improved ratings are achieved with present DH-5 oil burner having 1,725 rpm motor. Furnished with controls for forced circulation, the A-3 is tested and eouipped for 30 lbs. water working pressure. Unit is arranged to operate on 115 volt, 60 cycle power supply. WATER packaged unit number gross l=B=R output Mbh l=B=R burner capacity gph tankless heater number l=W=H rating net l=B=R rating Mbh net rating sq ft water "Trade Price with standard equipment approx. shipping weight chimney size Packaged units with factory installed tankless heater. With R8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control. A-33M-PT 108 1.00 222 4 93.9 626 $591.00 735 8 x8x 15 A-34M-PT 148 1.35 230 4 128.7 858 684.00 818 8x8* 15 A-35M-PT 188 1.70 328 4 V, 163.5 1090 785.00 956 8x8x 15 Packaged units less heater: With R8182F Aquastat combination, limit and circulator control, light sensing primary"control, one heater opening cover plate. A-33M-P 108 1.00 93.9 626 $558.00 720 8x8x 15 A-34M-P 148 1.35 128.7 858 649.00 801 8 x 8 x 15 A-35M-P 188 1.70 163.5 1090 739.00 944 8x8x 15 Nozzle sires, 9Ph, 70 solid, furnished with the above units: A-33, 1.00; A-34, 1.35; A-35, 1.75. A Gallons of water per minute heated from 4CTF to 140*F with 200*F bo.ler water temperature Standard equipment: Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. T822D thermostat. Scientifically designed pre-cast refractory combustion chamber. Nozzle Draft regulator. ASME relief valve. Pressure and temperature gauge. IV4" circulator with piping. Wiring harness. Drain valve. Optional equipment: See page 22. Note: Units are shipped with flush jacket and with all electrical controls (except thermo stat), circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately. Draft regulator, relief valve and thermostat shipped inside boiler crate. Zone valve packages are available for water boilers. For details and prices, see page 34. Ordering Examples: 1. Packaged unit with heater with optional equipment: 1 A-33 M-PT boiler-burner unit with jacket extension 2. Packaged unit less heater with standard equipment: 1 A-34 M-P boiler-burner unit 'W See page 56 Page 19 HH-11 02419 BOILER-BURNER UNITS WMEt AND STEAM rSl AMr''ICAN kSJSTA OARD HYDRONIC HEATING A-3 NON-PACKAGED ALL-PURPOSE BOILER-BURNER UNITS If you prefer your oil-fired boilers unpackaged for convenience and flexibility, choosr the A-3 Non-Packaged Boiler-Burner unit in one of five sizes for water or steam, with or without tankless heater. This boiler offers you A-3 versatility. It can be used on forced circulation or gravity systems or steam. New improved ratings are achieved with present DH-5 oil burner having 1,725 rpm motor. The flush jacket installs easily and provides free access to all controls and burner for quick adjustment and servicing. The factory assembled sections are tested and equipped for 30 lbs. water working pres sure. Motor and controls are regularly furnished for 115 volt, 60 cycle power supply WATER boilerburner unit number gross l=B = R output Mbh l=B = R burner capacity ) gph tankless | heater 1 number l=W==H rating net rating Mbh' net rating sq ft water Trade Price with standard equipment approx. shipping weight J_____________ chimney size Forced circulation units with factory installed tankless heater: With R8182D Aquastat relay combination, high limit, low limit and circulator control, light sensing primary control. A-33M-WBT 108 k. A34M-WBT 148 1.00 1.35 222 4 230 4 93.9 128.7 626 858 1 A-35M-WBT 188 1.70 328 4v, V A-36M-WBT 228 2.20 335 5>/2 163.5 198.3 1090 1322 A-37M-WBT 268 2.50 335 5Vz___ 233.0 1553 $480.00 573.00 674.00 770.00 860.00 666 756 878 1016 1148 8x8x15 8x8x 15 8x8x15 8x8x15 8 x 12 x 15 Forced circulation units less heater: With R8182F Aquastat combination, limit and circulator control, light sensing primary control. A-33M-WB A-34M-WB A-3SM-WB A-36M-WB A-37M-WB 108 148 188 228 268 1.00 1.35 1.70 2.20 2.50 93.9 128.7 163.5 198.3 233.0 626 658 1090 1322 1553 $447.00 536.00 626.00 719.00 809.00 658 740 875 1005 1138 8x8x 15 8 x 8 x 15 8x8x15 8x8x15 8 x 12 x 15 Gravity units less heater: With L4080A Aquastat limit control, and separate R8184G light sensing primary control. A-33M-WBG A-34M-WBG A-35M-WBG A-36M-WBG A-37M-WBG 108 148 188 228 268 1.00 1.35 1.70 2.20 2.50 93.9 128.7 163.5 198,3 233.0 626 858 1090 1322 1553 $443.00 534.00 624.00 715.00 805.00 657 739 874 1004 1137 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x 12 x 15 STEAM boiler- burner unit number gross l=B=R output Mbh l=B=R burner capacity gph tankless heater number l=WsH rating net l=B=R rating Mbh net |=B=:R sq ft steam Trade Price with standard equipment approx. shipping weight chimney size Steam units with factory installed tankless heater: With PA404A Pressuretrol, L4006A Aquastat operating control, and separate R8184G light sensing primary control. A-33M-SBT 108 1.00 222 3`A 81.0 338 $480.00 A-34M-SBT 148 1.35 230 3>/z 111.0 463 573.00 A-3SM-SBT 168 1.70 328 41/4 141.0 588 674.00 A-36M-SBT 228 2.20 335 4V4 171.0 713 770.00 A-37M-SBT 268 2.50 335 5>/4 201.0 838 860.00 667 752 879 1017 1149 8x8x 15 8x8x 15 8x8x15 8x8x 15 8x 12 x 15 Steam units less heater: With PA404A Pressuretrol, and separate R8184G light sensing primary control. A-33M-SB A-34M-SB A-35M-SB A-36M-SB A-37M-SB 108 148 188 228 268 1.00 1.35 1.70 2.20 2.50 81.0 338 $443.00 111.0 463 534.00 141.0 588 624.00 171.0 713 715.00 201.0 838 805.00 658 740 875 1005 1138 8x8x 15 8x 8x 15 8x 8x 15 8x8x 15 8x 12 x 15 -Nozzle sizes, gpn, 70 solid, furnished with the above units: A-33, 1.00: A-34, 1.35; A-35, 1.75; A-36, 2,25; A-37, 2.50. AGalions of water per minute heated from 40F to 140-F with 200"F bo ler water temperature Standard equipment: Zone valve packages are available for water boilers. For details and prices, see page 34. Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads T822D thermostat. Scientifically designed pre-cast refrac tory combustion chamber. Nozzle. Draft regulator. Drain valve. Units WITH water heater 1 cover plate with V4" control tapping Units LESS heater: 2 cover plates for heat er openings. Ordering Examples: 1 All-Purpose boiler-burner unit with slandord equipment for forced circulation, with heater 1 A-37M-W&T boiler-burner unit For gravity circulation 1 A-33M-WBG boiler-burner unit 2 All-Purpose boiler bu rner unit with optional equipment For forced circulation, less heoter 1 A-35M-WB boiler-bur net unit with two stoge fuel unit Water: ASME relief valve. Pressure and temperature gauge. Steam: ASME safety valve. Steam gauge Gauge glass with trimmings. Optional equipment: See page 22 HH-11 Page 20 See page 56 ^AMERICAN bd STANDARD HYDRONIC HEATING OIL FIRED BOILERS WATER AND STEAM A-3 ALL-PURPOSE OIL FIRED BOILERS For the boiler that spells quality and dependability, look no further than the A-3 with factory-assembled cast iron sec tion assembly that is tested and equipped for 30 lbs. water working pressure. The flush jacket slips on easily. This boiler provides outstanding performance. WATER boiler number gross l = B=R output Mbh l=B=R burner capacity *ph tankless heater number A rating net l=B=R rating Mbh Boiler with factory installed tankless heater--forced circulation net rating sq ft water Trade Price approx shipping weight chimney size A-33M-WT 108 1 00 222 4 93 9 626 A-34M-WT 148 1 35 230 4 128 7 858 A-35M-WT 188 1 70 328 4V. 163 5 1090 A-36M-WT 228 2 20 338 , 198.3 1322 A-37M-WT 268 2 50 335 5 V. j 233.0 1553 $315.00 408.00 509.00 605.00 695.00 613 698 825 962 1093 8x8x 15 8x8x15 8x8x15 8x8x15 8 x12 x15 Boiler less heater--gravity or forced circulation A-33M-W A-34M-W A-35M-W A-36M-W A-37M-W 108 148 188 228 ___2_6_8_ _ STEAM 1.00 1.35 1.70 2.20 2 50 boiler number-- gross l=B=R output Mbh l=B=R burner capacity fph tankless heater number A. I=W=H rating Boiler with factory installed tankless heater 93.9 128 7 163.5 198.3 233.0 net !=B=R rating Mbh 626 858 1090 1322 1553 $290.00 381.00 471.00 562.00 652.00 605 687 822 951 1083 net l=B=R sq ft steam yr Trade Price approx. 1 shipping j weight 8 x 8 x 15 8x8x 15 8 x 8 x 15 8 x 8 x 15 8 x12 x 15 chimney size A-33M-ST 108 1 00 222 3`A A-34M-ST 148 1.35 230 3*/2 A-35M-ST 188 1 70 328 4'/. A-36M-ST 228 2.20 335 4Vx A-37M-ST 268 2.50 335 5% 81.0 111.0 141.0 171.0 201.0 338 463 588 713 838 $315.00 408.00 509.00 605.00 695.00 614 699 826 963 1094 1 j 8x8x 15 8x8x 15 8 x 8 x 15 8 x 8 x 15 8 x 12 x 15 8oiler less heater A-33M-S A-34M-S A-35M-S A-36M-S A-37M-S 108 1 00 148 1 35 188 1.70 228 2.20 268 2 50 81.0 338 $290.00 606 8x8x15 111.0 463 381.00 688 8x8x15 141.0 588 471.00 823 8x 8x 15 171.0 713 562.00 952 8x 8x 15 201.0 838 652.00 1084 8 x12 x15 A Gallons of water per minute heated from 4CTF lo 140F with 200'F boiler water temperature Only l = B=R approved oil burners, such as the DH-5 burner, may be used wftn A-3 oil fired boilers. Other l = B = R approved burners are available. Consult your American Standard District Office for details Standard equipment; Scientifically designed pre-cast refrac tory combustion chamber. Drain valve Water: ASME relief valve Pressure and temperature gauge Steam: ASME safety valve Steam gauge Gauge glass with trimmings Optional Equipment, See page 22 A 3j A 37 Sdiu Assernui'es J*aiiooie ,it aoaeo i r aoe once c nar qe ot $16.00 Note: Boilers with factory installed tankless heater aie shipped with one water heater opening cover plate with 3/4" control tap ping Boilers less factory installed heater are shipped with an additional water heater opening cover plate (blank). Zone valve packages are available for water boilers. For details and prices, see page 34 Ordering txample$ 1. Woter boiler leis heoter with jtandord equip ment ) A-34M-W bdier 2 Steam boiler with heoter with stondard equip ment 1 A-36M-ST boiler 3 Water boiler with heoter with optional equip ment 1 A 35M WT boiler with jacket extension Page 21 HH-11 02421 BOILER-BURNER UNITS OIL FIRED BOILERS WATER AND STEAM rSl AMERICAN ISJSTANDARD HYDRONIC HEATING A-3 OPTIONAL EQUIPMENT FOR A-3 BOILER-BURNER UNITS AND OIL FIRED BOILERS Jacket extension: Jacket extension provides 16%" enclosure in front for concealment of oil burner and controls. Approx imate shipping weight 35 lbs. Specify on order. Added Trade Price $32.33 McDonnell & Miller No. 67AR low water fuel cut-off for quick hook up installationis available for A-3 steam boilers at added TradePrice of.......................................$31.15 Controls and control sets are shown on page 35. The No. 5Z Control Set can be used for circulator zoning with A-3 boiler-burner units with tankless heater. X No. 5Z set is required for each zone in addition to the first zone which is controlled by the No. 5 Control Set or equivalent. Added Trade Price $27.60 FOR A-3 PACKAGED AND ALL-PURPOSE BOILER-BURNER UNITS Two-stage fuel unit is available for DH-5 oil burner at added Trade Price charge of...........................................................$6.15 For substitution of No. 4 control set consisting of T822D thermostat, L4081B Aquastat limit and circulator control, plus R8184G light sensing primary control, instead of R8182F combination control, for non-packaged A-3 boiler- burner units for forced circulation LESS heater. Added Trade Price ........................ $12.45 For substitution of No. 5 control set consisting of T822D thermostat, L8124C Aquastat, limit, reverse and operating control, circulator relay, plus R8184E light sensing primary control, instead of R8182D combination control, for non- packaged A-3 boiler-burner units for forced circulation WITH tankless heater. Added Trade Price $4.90 Order R8182D Aquastat-relay combination instead of R8182F control to permit use of tankless heater with A-3 non-packaged boiler-burner units furnished less water heater. Added Trade Price $9.90 Order R8182E Aquastat-relay combination instead of R8182F control to provide room thermostat control of circulator. Added Trade Price $5.40 l=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR A-3 Heaters tested with boilers. Built-in tankless heaters can be ordered for separate shipment with units or boilers specified less heater as follows: unit no. 1=B=R burner capacity CPh heater no. l=W=H rating water steam ''Trade Price A-33 A-34 A-35 A-36 A-37 1.00 1.35 1.70 2.20 2.50 222 230 328 335 335 4 4 4% 5% 5% 3Vz 3*/2 4 Vi 4% 5>/4 $28.00 30.00 41.00 46.00 46.00 Gallons of water per minute heated from 40aF to 140*F with 200*F boiler water temperature. HH-11 See page 56 Page 22 AMERICAN kSiSTANDARD HYDRONIC HEATING pressure fired boiler-burner units WATER AND STEAM PFA-3 PRESSURE FIRED BOILER-BURNER UNITS The PFA-3 Pressure Fired Boiler is forced-draft with flame retention burner using No. 2 oil for over 80% efficiency. Attractive two-toned brown and beige jacket with optional matching acoustically treated jacket extension. Wet base construction eliminates need for separate base. Perfect seal between boiler sections is achieved with durable sealant. Factory assembled sections are tested and equipped for 50 lbs. water working pressure Motors and controls regularly furnished for 116 volt, 60 cycle power supply. WATER belter- buurnniet r number gran Islsl output Mbh . * l = B=* burner copoclty gph ttmkleii heater number + l = W=H rating l =nBe=t * rating Mbh net rating eq. ft. water Trade Price with itondard equipment approx. shipping weight e rent sire dlam. In. Forced circulation units with factory Installed tankless heater: No. 5 control set -- T822D thermostat, L8124C Aquastat. reverse and operating control, circulator relay, R8184G light sensing primary control. PFA-34-WT 300 2.65 226 6.0 260.9 1739 3 907.00 905 8 PFA-35-WT 375 3.30 232 7.5 326.1 2174 1026.00 1096 8 PFA-36-WT 450 3.95 445 9.0 391.3 2609 1150.00 - 1287 8 PFA-37-WT 526 4.60 445 9.0 457.4 3049 1262.00 1481 8 Forced circulation units less heater: No. 4 control set --T822D thermostat, L4081B Aquastat limit and circulator control R8184G light sensing primary control. PFA-34-W PFA-35-W PFA-36-W PFA-37-W 300 2.65 375 3.30 450 3.95 526 4.60 260.9 326.1 391.3 457.4 1739 2174 2609 3049 $ 859.00 970.00 1081.00 1193.00 894 1085 1276 1470 8 8 8 8 STEAM 1*1 beilerburner unit number grail l = B= output Mbh * Istst burner capacity Bph lankiest heater number t 1 = W=H rating net 1 = 8=1 rating Mbh net l=B = R *q. ft. steam 'W' Trode Price with standard equipment approx. shipping weight vent sice dfam. in. Steam units with factory Installed tankless heater: No. 2 control set -- T822D thermostat. PA404A Pressuretrol, L4006A Aquastat operating control, R8184G light sensing primary control. PFA-34-ST 300 2.65 226 6.0 225.1 938 $ 899.00 905 8 PFA-35-ST 375 3,30 232 7.5 281.3 1172 1018.00 1096 8 PFA-36-ST 450 3.95 445 9.0 337.6 1407 1143.00 1287 8 PFA-37-ST 526 4.60 445 9.0 394.6 1644 1254.00 1481 8 Steam units less heater: No. 1 control set--T822D thermostat, PA404A Pressuretrol, R8184G light se nslng prlma ry control. PFA-34-S PFA-35-S PFA-36-S PFA-37-S 300 2.65 375 3.30 450 3.95 526 4.60 225.1 281.3 337.6 394.6 938 1172 1407 1644 $ 848.00 959.00 1071.00 1182.00 900 1091 1282 1476 8 8 8 8 Nozzle sizes furnished with the above units: (S -- solid: H -- hollow) PFA-34, 2.50 gph 45 H; PFA-35, 3.25 gph 45 S; PFA-36, 4.00 gph 45 S; PFA-37, 4.50 gph 30 S. tGallons of water per minute heated from 40F to 140F with 200F boiler water temperature. Vent needs to extend only 3 feet above highest part of roof. Standard Equipment Water: ASME relief valve Pressure and temperature gauge Flange mounted oil burner with 2-stage fuel unit; factory installed light sensing cad cell with bracket and leads; V4046B instantaneous oil valve; Syracuse elec tronic time delay; drain valve. boiler-burner unit PFA-34 PFA-35 oil burner LC-334-A3 LC-334-A boilarbvrMr Ultlf PFA-36) PFA-37 f oil burner LC-534-A Steam: ASME safety valve Steam gauge Gauge glass with trimmings Optional Equipment Available in split assemblies. Specify on order. Added Trade Price . . $16.00 For other optional equipment see page 24. Units WITH water heater: 1 cover plate with control tapping. Units LESS water heater: 2 cover plates for heater openings. Ordering Examples: 1. Pressure fired boiler-burner unit with standard equipment with heater for water: 1 PfA-34-WT boiler-burner unit 2. Pressure fired boiler-burner unit with op tional equipment less heater for steam: 1 PFA-37-S boiler-burner unit with jacket extension HH-11 W See page 56 Page 23 Zone valve packages are available for water boilers. For details and prices, see page 34. 02423 PRESSURE FIRED BOILER-BURNER UNITS WATER AND STEAM S_i AMERICAN STANDARD HYDRONIC HEATING PFA-3 OPTIONAL EQUIPMENT Acoustically treated brown and beige jacket extension: Jacket extension provides 17};" enclosure in front for con cealment of oil burner and controls. Approximate shipping weight 42 lbs. Specify on order. Added Trade Price $38.00 No. 5-Z control set for circulator zoning with PFA-3 boiler- burner units equipped for tankless heater. 1 No. 5-Z set is required for each zone in addition to the first zone which is controlled by the No. 6 control set or equivalent. Trade Price of $27.60 McDonnell & Miller No. 67AR low water fuel cut-off for quick hook-up installation is available for PFA-3 steam units at added Trade Price of........................................ $31.15 McDonnell & Miller No. 63 low water cut-off is available for PFA-3 water units at added Trade Price of ...... $42.75 Controls and control sets are shown on page 35. I=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR PFA-3 Heaters tested with boilers. Built-in tankless heaters can be ordered for separate shipment with units or boilers specified less heater as follows: unit no. PFA-34 PFA-35 P FA-36 PFA-37 l=B=R burner capacity Bph 2.65 3.30 3.95 4.60 heater no. 226 232 445 445 | = W =H rating water team 6.0 6.0 7.5 7.5 90 9.0 9.0 9.0 pressure drop thru heater at rated flew 23 psi 36 psi 37 psi 37 psi Trade Price $40.00 48.00 61.00 61.00 Goffoni of wafer per minute from dOrF lo 14C*F with 200*F boiler woler iempra>u'e HH-11 See page 56 Page 24 * 02424 PFA-5 PRESSURE FIRED BOILER-BURNER UNITS PFA-5 Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 809c- efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 60 lbs. water working pressure; 80 lbs. water working pressure is optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good steam quality. Vent needs to extend only 3 feet above highest part of roof. OIL BOILER-BURNER UNITS STEAM ANO WATER pressure fired boiler-burner unit number oil 1 --B=R grot* burner 1 = B = * copodty Mbh oil SPh PFA-504-* O(T) PFA-505-* O(T) PFA-506-* O(T) 620 786 950 5.45 6.90 8.35 PFA-507-* 0(T) PFA-50B-* 0(T) PFA-S09-* O(T) PFA-510-* O(T) PFA-511-* O(T) PFA-512-* O(T) 1116 1282 1446 1612 1776 1944 9.80 11.20 12.65 14.10 15.55 16.95 PFA-513-* 0(T) PFA-514-* O(T) PFA-515-* O(T) 2108 2272 2440 18.40 19.85 21.25 PFA-516-* O(T) PFA-517-* O(T) PFA-51B-* O(T) 2604 2768 2936 22.70 24.15 25 60 PFA-519-* O(T) PFA-520-* O(T) PFA-521-* O(T) 3100 3260 3430 22,00 28.45 29.90 piping nd pickup fc steam water nei t = 0 -- R rating Mbh steam water sq. ft. steam 1 333 1.333 1.333 1.333 1.330 1.315 1.15 1.15 1.15 465 1 589.6 712.7 539.1 683.5 826.1 1.15 837.2 970 4 1.15 963.9 1114.8 1.15 1099.6 1257.4 1938 2457 2969 3488 4016 4582 1.302 1.292 1.2B8 1 15 1238.1 1401.7 1.15 1374.6 1544.3 1.15 1509.3 1690.4 5159 5728 6289 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7 1.15 2021.7 2264.3 1.15 2149.1 2407 0 1.15 2279.5 2553.0 1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982.6 6819 7350 7893 8424 8954 9498 10028 10546 11096 net rating sq. ft. water Trade Price with standard equipment ell vent size diom. in. opprov- Imote shipping weight burner model supplied with standard equipment ell 3594 4557 5507 *1406.00 10 1683.00 10 1853.00 10 1840 2210 2520 95A-1-8702-JA-T 96A-M-6131-J-T 96A-M-6131-J-T 6469 7432 8383 2151.00 10 23B6.00 10 2556.00 14 2880 3190 3550 96A-B-8316-JC-T 96A-B-8317-JC T 96A-B-8318-JC-T 9345 10295 11269 2993.00 14 3461.00 14 3738.00 14 3935 4285 4645 96A-T-A-8419-J-T 97A-T-A-8613-J-T 97A-T-A-8614-J-T 12220 13171 14145 3909.00 14 4111.00 14 4398.00 14 4955 5317 5675 97 A-T -A-8614-J-T 97A-T-A-8615-J-T 97A-T-2-7635-E-1 15095 16047 17020 4729.00 18 4931.00 18 5197.00 18 5985 6345 6750 97A Hi-Lo-2-7685-E-1 97A Hi-Lo-2-7685-E-1 98A H.-LO-2-7771-E-1 17971 18899 19884 5442.00 18 5623.00 18 5836.00 18 7060 7420 7780 98A-H(-Lo-2-7771-E-1 98A H.-Lo-2 7771-E-l 98A Hi-Lo-2-7771-E-1 The net tr=B=R ratings shown are based on piping and pick-up allowances listed above. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements. `Substitute letter "S" for steam; "W" for water. Start Up and One Year's Service . . . Price on Application Suffix (T) denotes boiler with openings in center section for tankless heaters when specified. For Built-in Water Heaters, see page 28. # Nozzle sizes, gph, furnished with the above oil burners are as follows: unit na. gph. type unit no. gph. type unit no. gph. type unit no. gph. typ* unit no. gph. type unit no. gph. type PFA-504 2 2.75 90H PFA-505 2 3.50 90* H PFA-506 2 4.00 80 *H PFA-507 1 4.50 70H 1 5.00 70"H PFA-508 2 5.50 80*H PFA-509 1 6.00 80`H PFA-512 2 7.00 70H PFA-514 1 3.50 60 H PFA-517 1 10.00 90S PFA-520 1 8.00 80$ 1 6.50 80H 1 2.50 70 H PFA-515 2 8.00 70H PFA-51B 1 7.50 90S 1 8.50 80S PFA-510 2 5.50 90*H PFA-513 2 7.00 70H 1 5.00 70H 1 8.00 90S 1 12.00 80S 1 2.75 90H 1 4.00 70 H PFA-516 2 7.00 90S 1 10.00 90S PFA-521 2 8.00 80S PFA-511 2 6.50 80H 1 8.50 90S PFA-519 2 7.50 80S 1 14.00 80S 1 2.00 80H PFA-514 2 8.00 60H PFA-517 2 7.00 90S 1 12.00 80S Standard Equipment--All Boilers Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve. Standard Equipment--Oil Fired Flange mounted oil burner--97A-T-A, 97A-T-2, 97A Hi-Lo and 98A Hi-Lo burners furnished with flange and pedestal; 2-stage fuel unit. One 95A-1, 96A-M, 96A-B, 96A-T-A and 97A-T-A burners, factory installed cad cell, bracket and leads, R8185E light sensing primary control; V4046B in stantaneous oil valve, ST70A1002 electronic time delay. On 97A-T-2, 97A Hi-Lo-2 and 98A Hi-Lo-2 burners, R4150A control--provides pre-purge and post-purge, Q520A base, factory installed C7013A photo cell; delayed and instantan eous oil valves, nozzles. Standard Motor Voltages PFA-504 thru PFA-610 116/60/1 PFA-511 thru PFA-521 230/60/1 Ordering Examples: PFA-5 boiler-burner unit for steam with standard equipment. 1--PFA-514-SO boiler-burner unit PFA-5 boiler-burner unit for wafer with optional equipment 1 -- PFA-511 -WO(T) with jacket extension; 4 No. 548 tankless heoters; with L6006A control Optional Equipment--Oil Fired Oil Burners equipped to meet F.M. and Massachusetts Code requirements for PFA-504 through PFA-514 Units are available when specified on order. Added Trade Price $159,00 Burners for PFA-515 through PFA-521 already equipped to meet F.M. requirements. Equipment includes: R4150A pro vides pre- and post-purge, C7013A Photo Cell and Q520A Base. Oil Burners to meet F.I.A. requirements--Price on applica tion. Oil burners for PFA-515 thru PFA-521 to meet Massa chusetts Code requirements -- Price on application. Optional burners available forPFA-504 thru PFA-510. see page 28. See page 56 Page 25 HH-11 02425 GAS BOILER-BURNER UNITS STEAM AND WATER PFA-5 PRESSURE FIRED BOILER-BURNER UNITS PFA-5 Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 80% efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure is optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good steam quality. preiture fired boiler-bumer unit number groii I =B =* output Mbh PFA-504-* G(T) PFA-505-* G(T) PFA-506-' G(T) PFA-507-' G(T) PFA-S08- G(T) PFA-509- G(T) PFA-51D-' G(T) PFA-511-' G(T) PFA-512- G(T) PFA-513- G(T) PFA-514- G(T) PFA-515- G(T) PFA-516-* G(T) PFA-517-* G(T) PFA-516-* G(T) PFA-519-* G(T) PFA-520-* G(T) PFA-521-* G(T) 620 786 950 1116 1282 1446 1612 1776 1944 2108 2272 2440 2604 2768 2936 3100 3260 3430 --Il =1 =* burner piping irtd capocity pickup input Mbh steam s|=t rot Mbh iq. it. toam 763 966 1169 1372 1568 1771 1974 2177 2373 1.333 1.333 1.333 1.333 1.330 1.315 1.302 1.292 1.288 1.15 1.15 1.15 465.1 589.6 712.7 539.1 683.5 826.1 1.15 837.2 970.4 1.15 963.9 1114.8 1.15 1099.6 1257 4 1.15 1238.1 1401.7 1.15 1374.6 1544.3 1.15 1509.3 1690.4 1938 2457 2969 3488 4016 4582 5159 5728 6289 2576 2779 2975 1.288 1.288 1.288 1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7 6819 3178 3381 3584 1.288 1.288 1.288 1.15 2021.7 2264.3 1.15 2149.1 2407.0 1.15 2279.5 2553.0 3786 I 3983 I 4186 1.288 1.288 1.288 1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982.6 net rating q. ft. wetsr 3594 4557 5507 6469 7432 8383 9345 10295 11269 12220 13171 14145 15095 16047 17020 17971 18899 19884 Trade Price with itandard equipment go* approx imate lie Uhlpping burner model igpplied with standard equipment gat $2216.00 2435.00 2644.00 2960.00 3206.00 3376.00 3822.00 4353.00 4648.00 4836.00 5038.00 5230.00 5554.00 5756.00 5938.00 6312.00 6493.00 6706.00 10 10 10 10 10 14 14 14 14 14 14 14 18 18 18 18 18 18 1840 B6 2-G-03-R4795-B 12S 2210 R6.2-G-03-R4795-B.12S 2520 R6.2-G-03-R4795-B.12 2880 R8-G-05-R4795-B.12 3190 R8-G-05-R4795-B.15 3550 R8-G-05-R4795-B.15 3935 R8.1-G-05-R4795-B.20 4285 R8.2-G-05-4150A-H.20 4645 R8.3-G-10-4150A-H.20 4955 5315 5675 R10.9-G-1CM150A-H.20 R10.9-G-10-4150A-H.20 R10.9-G-10-4150A-H.20 5985 6345 6750 R10-G-15-4150A-H.25S R10-G-15-4150AH.25S R 10.1-G-15-4150A-H.25S 7060 R10.1-G-2a4150A-H.25 7420 R10.l-G-2a4150A-H.25 7780 R10.1-G-20-4150A-H.25 The net t = B=R rating! shown are based on piping onu K.---------------selecting a boiler for installations having unusual piping and pick-up requirtmen s. Sb.ti,t. I.tt.r "S" for .fm, "W" for wo,or START-UP AND ONE YEAR'S SERVICE: INCLUDED IN TRADE PRICE OF GAS UNIT ,1, Suffix (T) denote, boiler with opening, in center section for ,ankle,, heater, when ,pec,fled. For Bu,l..,n Worer Heoter,. ,e. poge 28 Standard Equipment--All Boilers Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve. Standard Equipment--Gas Fired Flange mounted gas burner. Standard burner controls meet latest UL requirements. Dual automatic gas valves for added reliability. Gas-electric ignition. Electric program ming controls and components are factory wired in a con trol cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burners equipped to operate with 1,000 Btu, 0.6 specific gravity natural gas. Ordering Examples: PFA-5 boiler-burner unit for steam with standard equipment. 1--PFA-514-SG boiler-burner unit PFA-5 boiler-burner unit for water with optional equipment. 1"PFA-511-WG(T) with jacket extension; 4 No. 548 tankless heaters. Specify gas pressure available at gas train inlet. (1) Surcharge for SlarMJp and Service west of Mississippi River. Contact American-Standard for details. Optional Equipment Factory assembled sections available. Specify on order. Added Trade Price -- Per section $21.00 PFA-5 units are available with controls to meet Factory Mutual and Factory Insurance Association requirements at the following added charges: got tired boiler six* f *M. F.I.A. PFA-504--510 PFA-511--515 PFA-516--521 $710.00 541.00 562.00 $875.00 779.00 806.00 For prices of gas burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office. Hi-Lo Fire Control ..................................... Modulating Fire Control......................... Alarm System pre-wired and mounted on control cabinet............................................ Optional Combustion Controls ............... Price on Application Controls to meet local requirements ....... For Additional Optional Equipment, See page 28 Standard Motor Voltages The complex nature of the Gas and Gas-Oil Burners make them imprac tical to stock at Bond Plant. Therefore, please allow 3 to 4 weeks lea^ time for shipment of Standard Equipped Burners after receipt of order at Hydronie Order Service Center. unit number get burner* PFA-504--511 PFA-512-521 115-60-1 230-60-3 Other optional motor voltages--Price on Application. HH-11 See page 56 Page 26 02426 PFA-5 PRESSURE FIRED BOILER-BURNER UNITS GAS--IIGHT OIL BOILER-BURNER UNITS I'K \-f> Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for o\*.-r hOf;v efficiency and outstanding performance. Combustion chamber and separate base are not. required due to wet base design. Minimum stack required making boiler ideal for replace ment Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure is optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good steam quality. Vent needs to extend only 3 feet above highest part of roof. pretture fired boiler-bumer unit number gat--light oil a ai = -- | grott =B =l burner ropority , output Mbh got input Mbh piping and actor iteom water PFA-504-- GO(T) PFA-505-* GO(T)! PFA-S06-* GO(T) 620 763 786 966 950 1169 1 333 1.333 1 333 1 15 1 15 1 15 net 1 = B = R rating hMb steam water iq. ft team _________ j 465.1 589.6 712 7 539 1 683.5 826.1 1938 2457 2969 net rating sq ft. water 3594 4557 5507 ^Irode Price with standard equipment go*--ell $2606.00 2824.00 3106.00 vent site dlam. in. 10 10 10 approx imate shipping weight burner mdel supplied with itandard equipment a. ga*--oil 1840 2210 2520 R6 2-G0 03-R4795-B 12S-FIC R6.2-GO-03-R4795-B. 12S-F 1C R6.2GO-03-R4795-8.12-FIC PFA-507-* GO(T) 1116 1372 PFA-508-* GO(T) 1282 1568 PFA-509-* GO(T) 1446 1771 1 333 1 330 1.315 1.15 837.2 970 4 1.15 963.9 1114.8 1.15 1099.6 1257.4 3488 4016 4582 6469 7432 8383 3381.00 3678.00 3849.00 10 10 14 2880 3190 3550 R8-GO-05-R4795-B.12-F3 R8-G0-05-R4795-B. 15-F3 R8-GO-05-R4795-B.15-F3 PFA-510-* GO(T) PFA-511-* GO(T) PFA-512-* GO(T) PFA-513-* GO(T) PFA-514-* GO(T) PFA-S15-* GO(T) 1612 1974 1776 2177 1944 2373 2108 2576 2272 2779 2440 2975 1.302 1.292 1 288 1.288 1.288 1.288 1.15 1238.1 1401.7 1.15 1374.6 1544.3 1.15 1509.3 1690.4 1.15 1636.6 1833 0 1.15 1764.0 1975.7 1.15 1894.4 2121.7 5159 9345 5728 10295 6289 11269 6819 12220 7350 13171 7893 14145 4332.00 4690.00 5049.00 5240.00 5442.00 5634.00 14 14 14 14 14 14 3935 4285 4645 4955 5315 5675 R8.1-GO-05-R4795-B.2O-F3 R8.2-GO-07-4150A-H.20-F4H R8 3-G0-10-4150A-H.20-F4H R t0.9-GO-10-4150A-H.2O-F4H R10.9-GO-10-4150A-H.20-F4H R10.9-GO-10-4150A-H.20-F4H PFA-516-* GO(T) PFA-517-* GO(T) PFA-51B-* GO(T) PFA-519-* GO(T) PFA-520-* GO(T) PFA-S21-* GO(T) 2604 3178 2768 3381 2936 3584 3100 3780 3260 3983 3430 4186 1.288 1.288 1 288 1.288 1.288 1 288 1.15 2021.7 2264.3 1.15 2149.1 2407.0 1.15 2279.5 2553.0 8424 8954 9498 15095 16047 17020 1.15 2406.8 2695.7 1.15 2531 1 2834.8 1.15 2663.0 2982.6 10028 10546 11096 17971 18899 19884 5955.00 5158.00 6417.00 6728.00 6995.00 7208.00 18 18 18 18 18 18 5985 6345 6750 7060 7420 7780 R10-GO-15-4150A-H.25S-F4H R10-GO-1 5-4150A-H.25S-F4H R10 1-GO-20-4150A-H.25S-F4H R10.1-GO-20-4150A-H.25-F4H R10 1 -GO-30-41 50A-H.25-F4H R10.1-GO-30-4150A-H.25-F4H The net I =: B = R rating* thownw based on piping and pick-up allowances listed above. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements. Substitute letter "S" for steam, "W" for water. START-UP AND ONE YEAR'S SERVICE: INCLUDED IN TRADE PRICE OF GAS-OIL UNIT.(l) Suffix (T) denotes boiler with openings in center section for tankless heaters when specified. For Built-in Water Heaters, see page 28 Standard Equipment--All Boilers Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve. Standard Equipment--Gas-Light Oil Fired Flange mounted combination gas-oil burner. Standard burner controls meet latest UL requirements. Manually operated fuel switch for dual fuel change-over. Dual auto matic gas valves for added reliability. Gas-electric ignition. Electric programming controls and components are factory wired in a control cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burner equipped to operate on No. 1 or No. 2 fuel oil and 1,000 Btu, 0.6 specific gravity natural gas. Standard Motor Voltages uml number gai-oil burner* PFA-504--510 115-60-1 PFA-511 PFA-512-521 230-60-1 230-60-3 Other optional motor voltages--Price on Application. (1) Surcharge for Start-Up and Service weft of Mississippi River. Contoct American-Standard far details. Ordering Examples: PFA-5 boiler-burner unit for steam with standard equipment. 1--PFA-514-SGO boiler-burner unit. PFA-5 boiler-burner unit for water with optionol equipment. I-- PFA-511-WGO(T) with jacket extension; 4 No. 548 tankless heaters. Specify gat pretture available at gat train inlet dBaNozzte sizes, gph, furnished with combination gas-light oil burners are as follows: (nozzle capacity is dependent on oil pressure.) unit no. gph. type unit no. gph. type unit no. gph. type PFA-504 1 4.00 90H PFA-505 1 5 00 90H PFA-506 1 6.50 90H PFA-507 2 4.00 90S PFA-508 2 4.00 90S PFA-509 2 5.00 90S PFA-510 2 5.00 90S PFA-511 2 5.50 90S PFA-512 2 6.00 90S PFA-513 2 7.00 60S PFA-514 2 7.00 60S PFA-515 2 7.00 60S PFA-516 2 7.00 60S PFA-51 7 2 8.00 60S PFA-518 2 8.00 60S PFA-519 2 8.00 60S PFA-520 2 8.50 60S PFA-521 2 9.00 60S Optional Equipment PFA-5 units are available with controls to meet Factory Mutual and Factory Insurance Association requirements at the following added changes: gos-oif fired boffer sfse f.M. f t.A. PFA-504--510 PFA-511 --515 PFA-S16-521 $685.00 710.00 731.00 $1018.00 928.00 928.00 Automatic Fuel Changeover Trade Priced............................................................. $183.00 For prices of gas-oil burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office. Hi-Lo Fire Control............................................ Modulating Fire Control........................... Price Alarm System pre-wired and mounted on control cabinet................................................. on Optional Combustion Controls . .................... Application Controls to meet local requirements . . . The complex nature of the Gas and Gas-Oil Burners make them imprac tical to stock at Bond Plant. Therefore, please allow 3 to 4 weeks lead time for shipment of Standard Equipped Burners after receipt of order at Hydrome Order Service Center. See page 56 Page 27 HH-11 02427 BOHER-BURNER units OIL FIRED BOILERS WATER AND STEAM rs\ AMERICAN Si STANDARD HYORONIC HEATING PFA-5 OPTIONAL EQUIPMENT Jacket extension: Jacket extension provides 34 */" enclosure ir front for concealment of burner and controls. Approxi- iv.ii'* shipping weight 90 lbs Specify on order Added Trade Price $63.00 PFA-5 boilers tested for 80 lbs. water working pressure: available when specified on order. Add to Trade Price of water boiler........................................................$8.00 per section Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows: PFA-5 .Trade Price each $3.90 Optional burners to provide low fire start (with cad cell) for PFA504 thru PFA508; Hi-Lo operation provided (with cad cell) for PFA609 and PFA610. Please allow four weeks lead time after receipt of order at the hydronic order serv ice center. unit PFA 504 PFA 505 PFA 506 PFA 507 PFA 508 PFA 509 PFA 510 burner model 96A-T-A 8406-JJ30-T 96A-T A 8407 JJ30-T 96A-T-A 8408 JJ15 T 96A-T-A 8409-JJ15-T 96A-T-A 8410-JJ15 T 96A-HI LO-A-8808-JJ15-T 96A-HI UO-A-8808 JJ15-T add le Trade Price $126.00 113.00 119.00 57.00 57.00 256.00 198.00 Factory assembled sections available. Specify on order. Added Trade Price per section $21.00 TANKLESS WATER HEATERS FOR A-5, FRA-5 AND PFA-5 Tankless water heaters are available in any quantity at the following Trade Prices: healer numb*' wind with Trode Pric loth 530 548 A-5. FR-A-5 PFA-5 $40.00 66.50 PFA-5 units with tankless water heaters require additional controls at current prices as follows: STEAM: L4006A Aquastat operating control. Trade Price $14.05 WATER: L6006A Aquastat operating and circulator control. Trade pricc $14.90 Factory assembled copper pipe manifold for parallel hook up of multiple heaters are available as follows: manifold auembly Trode Pnci lor A-5, FR-A-5 2 Heater 3 Heater 4 Heater $ 8.20 12.00 15.25 When suffix "T" is added to boiler number on order for A-5, FR-A-5 or PFA-5 boilers or units, maximum number of centei sections with water heater openings are furnished at no extra charge as follows: Except where noted by asterisk in which case max. number of openings minus one is furnished unless max. number is specified on order. A-5 and FR-A-5 belter A-5 or FR-A-504 T A-5 or FR-A-505-T thru 507-T A-5 or FR-A-508-T*thru 509-T A-5 or FR-A-510 T*thru 511-T* max. no. of opening* 2 3 4 5 PFA-5 boiler PFA-504T PFA-505-T thru 506-T PF A-507-T thru 508-T PF A-509-T thru 511-T max. no. ol openings 1 2 3 4 PFA-5 boiler PFA-512-T thru 514-T PFA-515-T thru 517-T PFA-518-T thru 519-T PF A-520-T thru 521-T The following table shows ratings attained if more than one heater is connected in parallel: lonkle** heeler no. 530 boiler number no of heelers ! *ro1ing gpm. boiler number rankle** heoler No 546 no ol heater* A-5 or FR-A-5-T all sizes A-5 or FR-A-5-T all sizes A-5 or F R-A-505-T thru 51 I T A-5 or F R-A-508-T thru 511-T A-5 or FR-A-510-T thru 51 I T 1 i ! 14 2 ;7 3 1 10 4 ! 13 5 ! 16 , PFA-5-T all sizes PF A-505-T thru 506-T PF A-507-T thru 508-T PF A-509-T thru 511 -T PFA-512-T thru 514-T PFA-515-T thru 517 T PFA-518-T thru 519-T PF A-520-T thru 521-T 1 2 3 5 6 7 8 Gollon* of wo'*' per minuie 'oued I'om 40*F lo 140F with 200F bo<ler wole' lemperaiure mox. no of | openings ;1 65 !7 i8 j *rotmg gpm !8 : is 24 i 32 1 40 i 48 i1 5664 McDonnell & miller low water cut-offs STEAM: No. 369 Low Water Cut-off for A-5, FR-A-5, PFA-5 ... -- -- No. 47-2 Feeder and Cut-off for A-5, FR-A-5, PFA-504 thruPFA-509 No. 51-2 Feeder and Cut-off for PFA-510 thru PFA-521 WATER--50 PSI: No. 63 Low Water Cut-qff for A-5, FR-A-5 andPFA-5 WATER--80 PSI: No. 150 Low Water Cut-off for PFA-5 HH-11 See page 56 Page 28 "Trade Price $25.25 73.00 94.00 42.75 64.25 a I 02428 ^AMERICAN ^STANDARD HYDRONiC HEATING boiler-burner units WATER AND STEAM FR-A-5 fLAME RETENTION BOILER-BURNER UNITS The FR-A-5 is a perfect combination of boiler and burner teamed for top performance. Develops 12V* COj. Tested and equipped for 50 lbs. water working pressure. Motors and controls regularly furnished are for 115 volt, 60 cycle power supply. WATER boiler-burner unit number gross 1 =B = R output Mbh l=B=R burner capacity gph net l=B=R rating Mbh net rating sq. ft. water Trade Price with standard equipment For Built-in Water Heaters, Steam and Water Boilers, see page 28. approx shipping weight chimney size H | 1 \ FRA-504-WB(T) FR-A-505-WB(T) FR-A-506-WB(T) FR-A-507-WB(T) FR-A-508-WB(T) FR-A-509-WB(T) FR-A-510-WB(T) FR-A-511-WB(T) 384 472 560 648 736 824 912 1000 3.55 4 30 5 10 5.90 6.70 7.45 8.25 9 05 333.9 410 4 487.0 563.5 640.0 716.5 793 0 869.6 2226 2736 3246 3756 4266 4776 5286 5797 $1025.00 1136.00 1325.00 1448.00 1602.00 1719.00 1843.00 1967.00 1576 1827 2110 2367 2626 2890 3144 3392 12 x 12 x 15 12 x 12 x 20 12 x 12 x 20 12 x 16 x 20 12 x 16 x 20 12 x 16 x 20 16 x 16 x 20 1 6 x 16x20 - = = | STEAM boiler-burner unit number gross l=B R output Mbh 1 =6 = R burner capacity gph net l = B = R rating Mbh sq. ft. steam Trade Price with standard equipment approx shipping weight chimney size yHUI Hf GREW w FR-A-504-SB(T) FR*A-505-SB(T) FR-A-506-SB(T) FR-A-507-SB(T) FR-A-508-SB(T) FR-A-509-SB(Tj FR-A-510-SB(T) FR-A-511-SB(T) 384 472 560 648 736 824 912 1000 3.55 4.30 5.10 5.90 6.70 7.45 8.25 9.05 288.1 354.1 420.1 486.1 552.1 618.2 684.2 750.2 1200 1475 1750 2025 2301 2576 2851 3126 $1025.00 1136.00 1325.00 1448.00 1602.00 1719.00 1843.00 1967.00 1577 1828 2112 2369 2628 2892 3147 3395 12 x 12 x 15 12 x 12 x 20 12 x 12 x 20 12 x 16 x 20 12 x 16 x 20 12 x 16 x 20 16 x 16 x 20 16 x 16 x 20 'Noz2ie sizes gph, furnished with the above units FR-A 504, 2 1 75 80 H; FR-A 505, 1 2 00 & 1 2.25 80 H, FR A 506, 1 4 00 70 S (200 Psig.) FR A 507, 1 4 50 70 S (200 Psig). FR A 508, 1 3 25 & 1 3 50 70 S; FR A 509, 1 3 50 & 1 4 00 70 S, FRA-510. 2 4 00 70 S, FR A 511. 2 4 50 70 S Suffm "T" denotes unit with openings m center sections for tankless heaters Start-up and one year service available Price on application. Standard equipment Flange mounted oil burner with 2-stage fuel unit; factory installed light sensing cad cell, bracket and leads; R8184G light sensing primary control. Delayed oil valve except on model 92A-7240-D and 92A-7242-D oil burners. boiler-burner unit number FR-A-504 FR-A-505 FR-A-506, FR-A-507 FR-A-508 oil burner 92A-7240-D 92A-7242-D 95A-300-7468-D (200 Psig fuel unit) 96A-M-7498-D boiler-burner unit number FR-A-509 FR A-510, FR-A-511 Draft regulator Drain valve oil burner 96A-M-7546-B 96A-M-7548-B Water: No. 3 control set: T822D thermostat L4080B Aquastat limit control Nozzle(s) ASME relief valve Pressure and temperature gauge Steam: No. 1 control set: T822D thermostat PA404A Pressuretrol Nozzle (s) ASME safety valve Steam gauge Gauge glass with trimmings Optional Equipment Jacket extension: Jacket extension provides 25" enclosure in front for concealment of oil burner and controls. Approxi mate shipping weight 57 lbs. Specify on order. Added Trade Price $41.00 Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows: Trade Price each $4.00 For Factory Mutual Approval and Massachusetts code requirements, special electronic flame safeguard controls are available, with RA890 Protectorelay, W415A control panel (includes Q270A base and R488F switching relay), C7013A photocell Delayed oil valve. Control sets other than those included in Trade Price of FR-A-5 boiler-burner units will be furnished on order at the following added charges: Control Set added charge Steam control set No. 2 $15-00 oil heating unit FR-A-504 FR A 505 FR-A-506, FR-A-507 FR A-508 FR-A-509 FR-A 510, FR-A 511 burner model 92A-7240-L 92A 7242 L 95A-300 7468-L 96A-M-7498 L 96A M-7546 L 96A-M-7548 L added Trade Price charge Water control set No. 5 Water control set No 5-Z 22.00 27.75 $153.00 153.00 134.00 153.00 146.00 146.00 (Add-on zone Use only with No 5 Control Set The No 5 Z control set for circular zoning on units with tankless heaters ) Ordering Examples: 1 Boiler-burner unit with standard equipment 1 FR-A 506 SB oil heating unit 2 Boiler burner unit lor steam with optional equipment 1 FR A 509 SB T with No control set. 3 No. 530 tankless heaters, 1 3 heater manifold 2 See page 56 Page 29 HH-11 02429 FLAME RETENTION BOILER-BURNER UNITS WATER AND STEAM ^AMERICAN LSiSTANDARD HYDRON1C HEATING FR-A-7 FLAME RETENTION BOILER-BURNER UNITS The perfect combination of boiler and burner teamed for top performance develop? l2K<fc C02. Available with or less jacket. Tested and equipped for 50 lbs. water working pressure. Operating controls furnished for 115 volt, 60 cycle pow'er supply. WATER boiler-burner unit number FR-A-706-WO-B FR-A-707-WO-B FR A-708-WO-B FR-A-709-WO-B FR-A-710-WO-B FR-A-711-WO-B FR-A-712-WO-B FR-A-713-WO-B FR-A-714-WO-B gross l = B= R output Mbh 1160 1376 1580 1812 2020 2228 2440 2720 3000 l=B=R burner capacity SPh net l=B=R rating Mbh A piping 4 pick-up factor 10.55 12.30 14.15 16.35 18.15 20.20 21.95 24.10 26.30 1008.7 1196.5 1373.9 1575.7 1756.5 1937.4 2121.7 2365.2 2608.7 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 net rating tq. ft. water unjacketed Jacketed Trade Price with standard equipment approx. Trade Price shipping with standard weight equipment approx. shipping weight chimney size 6724 7976 9159 10504 11710 12916 14144 15768 17391 $2242.00 2473.00 2938.00 3143.00 3467.00 3690.00 4248.00 4458.00 4768.00 4968 5626 6439 7223 7910 8558 9264 9950 10678 $2363.00 2611.00 3093.00 3410.00 3655.00 3894.00 4470.00 4697.00 5023.00 5144 5814 6750 7445 8149 8814 9534 10240 10988 16 x 16 X 30 16 x 20 x 35 16 x 20 x 35 20 x 20 x 40 20 x 20 x 45 20 x 20 x 55 20 x 24 x 60 20 x 24 x 70 24 x 24 x 80 STEAM boiier-bumer unit number FR-A-706-SO-B FR-A-707-SO-B FR-A-708SO-B FR-A-709SO-B FR-A-710-SO-B FR-A-711-SO-B FR-A-712-SO-B FR-A-713-SO-B FR-A-714-SO-B gross l-B-R output Mbh |=B=R burner capacity gph 1160 1376 1580 1812 2020 2228 2440 , 2720 3000 10.55 12.30 14.15 16.35 18.15 20.20 21.95 24.10 26.30 net l=B== R rating Mbh sq. ft. steam 870.2 1041.6 1211.7 1403.6 1568.3 1729.8 1894.4 2111.8 2329.2 3626 4340 5049 5848 6535 7208 7893 8799 9705 piping & pick-up factor unjacketed Trade Price with standard equipment approx. shipping weight jacketed Trede Price with standard equipment approx. shipping weight chimney size 1.333 1.321 1.304 1.291 1.288 1.288 1.288 1.288 1.288 $2242.00 2473.00 2938.00 3143.00 3467.00 3690.00 4248.00 4458.00 4768.00 4970 5629 6441 7228 7915 8560 9266 9952 10680 $2363.00 2611.00 3093.00 3410.00 3655.00 3894.00 4470.00 4697.00 5023.00 5146 5817 6752 7450 8154 8816 9536 10242 10990 16x 16x 30 16 x 20 x 35 16 x 20 x 35 20 x 20 x 40 20 x 20 x 45 20 x 20 x 55 20 x 24 x 60 20 x 24 x 70 24 x 24 x 80 *American-Standard should be consulted before selecting an FR boiler-burner unit for installations having unusual piping and pick up requirements 'Nozzle sizes, gph, furnished with the above units: FR-A-706. I 5 00 4 1 5.50 80* S: FR-A-707, 2 6 00 80s S. FR A 708, 1 2 00 4 2 6 00 90 S: FR A 709. 1 3.00 4 2 6.50 90* S; FR-A-710, 2 9.00 70* $; FR-A-711. 2 10.00 70* S; FRA 712. 2 6 00 4 1 10.00 80fr S. FR A 713. 2 6 00 4 1 12 00 80: S, FR-A-714 1 8 00 4 2 9 00 80* S Start-up and one year service available. Price on application Standard equipment: Pedestal mounted oil burner with 2-stage fuel unit; on 96A-M-7543-B and 9708111-B burners, factory installed cad cell, bracket and leads: R8184B light sensing primary control. On 96A-T burners, RA890 Protectorelay and Q270A base, C7013A photocell; on 97A Hi-Lo and 98A Hi-Lo burners, R4150A Flame Safe guard control -- provides prepurge and postpurge, Q520A base, C7013A photocell. Delayed oil valve (2 with 96-A-T). Delayed and instantaneous valves with 97A Hi-Lo and 98A Hi-Lo. boiier-bumer unit number oil burner standard motor voltage FR-A-706, FR-A-707 FR-A-708 FR-A-709 FR-A-710, FR-A-711 FR-A-712, FR-A-713 FR-A-714 96A-M-7543 B 96A-T-7935-K 96A-T-7937-K 970-8111-B 97A Hi-Lo-7673 E 98A Hi-Lo-7773-E 115/60/1 115/60/1 115/60/1 115/60/1 230/60/1 230/60/1 12" cast iron base on all units. In addition, 8" high steel pedestal base is furnished with 8 through 14 section units. Draft regulator. Water: L4080B Aquastat limit control Steam: PA404A Pressuretiol Nozzles ASME relief valve Pressure and temperature gauge Optional equipment: See page 33. Nozzles ASME safety valve Steam gauge Gauge glass with trimmings Combustion chamber not furnished. See lnstallation.Operetion and Maintenance Manual for combustion chambers required for FR-A-7 boiler-burner units. N*e.' For Optional Electronic Flame Safeguard Control Equipment, See Page 33. Ordering Examples: 1 Boiler-burner unit for steam jacketed with standard equipment 1 FR-A-710-SO-B boiler burner unit 2 Boiler-burner unit for water less jacket with optional equipment 1 FR;A-707-W0-B boiler burner unit with electronic flame safeguard controls to meet Factory Mutual Approval. HH-11 See page 56 Page 30 02430 ^AMERICAN C4 STANDARD HYDRONIC HEATING oil fired boilers WATER AND STEAM A-5 OIL FIRED BOILERS WATER This boiler is designed for large residences, apartment and commercial buildings. Tested and equipped for 50 lbs. water working pressure. boiler number gross l=B = R output Mbh t=B = R burner capacity iph net |s=B = R rating Mbh net rating sq ft water Trade Price approx. shipping weight For Built-in Water Heaters, Steam and Water Boilers, see page 28. A-504-WCT) A-505-W(T) A-506-W(T) A-507-W(T) A-508-WCTj A-509W(T) A-510-W(T) A-511-W(Tj 261 2.55 227.0 1513 $ 744.00 346 3.30 300.9 2006 855.00 426 4.00 370.4 2469 974.00 508 4.75 441.7 2944 588 5.55 511.3 3408 668 6.30 580.9 3872 1097.00 1215.00 1332.00 748 7.00 650.4 4336 830 7.65 721.7 4811 1455.00 1580.00 1518 1770 2025 2282 2539 2794 3050 3298 chimney size 8 x 12 x 15 8x 12 x20 12 x 12 x 20 12 x 12 x 20 12 x 16 x 25 12 x 16 x 25 12 x 16 X 25 16 x 16x30 STEAM boiler number A-504-S(T) A-505-SCO A-506-S(T) A-507-SCT) A-508-S(Tj -- A-509-S(T) A-510-SCT) A-511-S(T) gross IsBsR output Mbh 261 346 426 508 588 668 748 830 l = B=R burner capacity gph 2.55 3.30 4.00 4.75 5.55 6.30 7.00 7.65 net l = B= R rating Mbh sq ft steam 195.8 259.6 319.6 381.1 441.1 501.1 561.1 622.7 816 1082 1332 1588 1838 2088 2338 2594 Trade Price $ 744.00 855.00 974.00 1097.00 1215.00 1332.00 1455.00 1580.00 approx. shipping weight 1519 1771 2027 2284 2541 2796 3052 3300 chimney size 8 x 12 x15 8 x 12 x 20 12 x 12 X 20 12 x 12 x 20 12 x 16x25 12x16x25 12 x 16 x 25 16 x 16x30 Suffix "T" denotes boiler with openings in center sections for tankless heaters. Standard equipment: Optional equipment: Water: ASME relief valve Pressure and temperature gauge Drain valve Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows: Trade Price each $4.00 Steam: ASME safety valve Steam gauge Zone valve packages are available for water boilers. For details and prices, see page 34. Gauge glass with trimmings Drain valve Oil Burners available on special order............................................. Price on Application Ordering Examples: 1. Boiler only for steam with standard equipment: 1 A-507-S boiler. 2. Boiler only for water with optional equipment: 1 A-506-W boiler with jacket extension Jacket extension: Specify on order and add $41.50 to Trade Price of boiler or unit. Jacket extension provides 25" en closure in front for concealment of oil burner and controls. Approximate shipping weight 57 lbs. A-5 OPTIONAL EQUIPMENT HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS unit number A-504 A-505 A-506 A-507, A-508 A-509, A-510, A-511 Heat Llb-O-Rator model No. included 14A 15A 15-AA 16-A 17-A maximum firing rate gallons per hour 2.55 3.30 4.00 5.55 7.65 Trade Price $38.00 $38.00 47.00 47.00 55.00 approx. shipping weight 158 163 176 180 200 See page 56 Page 31 HH-11 OIL FIRED BOILERS WATER AND STEAM AMERICAN kSJ STANDARD HYDRONIC HEATING A-7 OIL FIRED BOILERS Ideal for commercial and industrial buildings. Available with or less jacket. Tested and equipped for 60 lbs. water working pressure. WATER boiler number gross l=B=R output Mbh l =B=R burner capacity gph net l=B=R rating Mbh A piping & pick-up factor net rating sq. ft. water unjacketed w approx. Trade Price shipping weight jacketed Trade Price approx. Shipping weight chimney size A-705-WO A-706-WO A-707-WO A-708-WO A-709-WO A-710W0 A-711-WO A-712-WO A-713-WO A-714-WO 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 21.45 23.20 753.0 880.0 1040.0 1196.5 1365.2 1530.4 1700.9 1867.8 2034.8 2201.7 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 5020 5866 6933 7978 9101 10202 11339 12452 13565 14678 (1723.00 1879.00 2112.00 2334.00 2539.00 2752.00 2974.00 3155.00 3343.00 3559.00 4186 4787 5445 6029 6669 7330 7956 8616 9278 9944 (1827.00 2001.00 2249.00 2489.00 2710.00 2939.00 3179.00 3376.00 3603.00 3812.00 4358 16 x 16 x 28 4963 16 x 16 x 30 5633 16 x 20 x 36 6240 16 x 20 x 42 6891 16 x 20 x 45 7569 20 x 20 x 50 8212 20 x 20 x 55 8886 20 x 20 x 60 9568 20 x 24 x 70 10254 20 x 24 x 80 STEAM boiler number A-705-S0 A-706-SO A-707-50 A-708-SO A-709-SO A-710S0 A-711-SO A-712SO A-713SO A-714-SO gross l=B=R output Mbh l=B=R burner capacity gph 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 21.45 23.20 net 1 = B=R rati ng unjacketed Mbh sq ft steam A piping & pick-up Trade Price factor approx. shipping weight jacketed w Trade Price approx. shipping weight chimney size 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 1816.8 1965.8 2707 3163 3738 4340 5013 5672 6328 6949 7570 8191 1.333 1.333 1.333 1.321 1.305 1.293 1.288 1.288 1.288 1.288 (1723.00 1879.00 2112.00 2334.00 2539.00 2752.00 2974.00 3155.00 3343.00 3559.00 4187 4788 5447 6030 6673 7334 7957 8617 9279 9945 (1827.00 2001.00 2249.00 2489.00 2710.00 2939.00 3179.00 3376.00 3603.00 3812.00 4359 16 x 16 x 28 4964 16 x 16 x 30 5635 16x20x36 6241 16 x 20 x 42 6895 16 x 20 x 45 7573 20 x 20 x 50 8213 20 x 20 x 55 8887 20 x 20 x 60 9569 20 x 24 x 70 10255 20 x 24 x 80 * The net l = B=R ratings shown are based on piping and pick-up allowances listed in the column next to the ratings American Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements Standard equipment: Water: ASME relief valve Pressure and temperature gauge Steam: ASME safety valve Steam gauge Gauge glass with trimmings Optional Equipment: Steel pedestal bases for installation under the regularly furnished 12 inch cast iron base for greater base heights are available on order at the fol lowing added charges: lection tire bon height strode Price 5 thru 7 8 thru 14 8" 10' $59.00 96.00 If steel pedestal base is not used, consideration should be given to the use of brick or masonry base as required. For Additional Optional Equipment, See page 33. Combustion chamber not furnished. See Installation-Operation and Maintenance Manual far combustion chambers required far A-7 boilers. Ordering Examples: 1. Boiler only with jacket for steam with optional equipment 1 A 711 SO boiler jacketed with steel pedestal base 2. Boiler only unjacketed for water with standard equipment 1 A-706-WO unjacketed Note: Be sure to specify on order letter "0" after fired boiler will be supplied or "W" or coal HH-11 See page 56 Page 32 02432 AMERICAN STANDARD HYDRONIC HEATING on burners OPTIONAL EQUIPMENT A-7 AND FR-A-7 OPTIONAL EQUIPMENT ELECTRONIC FLAME SAFEGUARD CONTROL EQUIPMENT For Factory Mutual Approval requirements, special electronic flame safeguard controls are available with RA890 Protectorelay, W415A control panel (includes Q270A base and R488F switching relay),C7013A photocell. Delayed oil valve. (2 with 96A-T-7935-R and 96A-T-7937-R.) Oil burners to meet Massachusetts Code requirements -- Price on application. boiler-burner unit FR-A-706, FR-A-707 FR-A-708 FR-A-709 FR-A-710, FR-A-711 burner model 96A-M-7543-L 96A-T-7935-R 96A-T-7937-R 970-8111-R added Trade Price charge $139.00 46.00 46.00 139.00 NOTE: R4150A Flame Safeguard control on 97A Hi-Lo and 98A Hl-Lo burners used with FR-A-712, FR-A-713 and FR-A-714 units meets Factory Mutual Approval and Massachusetts code requirements. McDonnell &. Miller low water cut-off and feeder combinations or low water cut-offs are available for FR-A-7 and A-7 steam units and boilers at added Trade Prices as follows: unit or boiler no. M&M no. Added Trade Price FR-A-706. A-705 thru A-707 FR-A-707 thru FR-A-713 A-708 thru A-714 FR-A-714 A-7 and FR-A-7 47-2 51-2 51-S-2 369 $ 72.70 93.90 106.00 25.23 Provision for special equalizer tapping (1" I.P.S. maximum) for bottom connection of 51 -2 or 51-S-2 is located 12V* inches below water line on front section. Other temperature controls are shown on page 36. FR-A-7 and A-7 external water heater tappings: two 1" tappings will be furnished on center sections for water boilers only. Lower tapping 23" from bottom of section. Center to center dimension between tappings is 21W. If desired specify on order and add $11.75 per "C" section to Trade Price of boiler. DfcUOIL BURNERS The DH burner is designed and built to exacting standards for dependable and trouble free operation. The quiet motor and reliable controls are regularly furnished for 115 volt, 60 cycle power supply. model number DH-5 DH-8 DH-15 DH-23 capacity qal. per hour .55 3.00 .65 - 3.00 ,65 - 3.00 .65 - 3.00 air tube diem. length mounting Trode Price with noxzle includes factory installed cad cell with no. 1 or no. 3 central set and primary control with primary central end nozzle less cod ceil 45 sling 4 8 / pedestalT 4 15 < r > 4 23 l flange ) $155.00 155.00 157.00 159.00 $137.00 139.00 141.00 $105.00 109.00 111.00 app. ship, weight with control set 55 60 64 68 boiler-bumer unit oil burner controls AP(T) BDH-5 A-3 packaped unit DH-5 {Primary control, cad cell and ) controls, except thermostat, ) factory installed. [ Draft regulator. A-3 boiler unit DH-5 /Primary control, controls. < Cad cell factory installed. (.Draft regulator. Note: For A-3 units pressure ring is packed with DH-5 burner. DH-5 burners for AP(T) packaged units furnished with refractory turbulator and are not interchangeable with other DH-5 models. Nozzles with Strainers for OH burners used with boiler-burner units: Solid cone 60 with AP(T), solid cone 70 with A-3 pack aged or boiler-burner units. Oil burners listed in this Price Book are approved by the National Board of Fire Underwriters, comply with U. S. Government Commercial Standard CS-75, and are for use with No. 1 or No. 2 fueloil. Capacities of oil burners using No. 1 or No. 2 fueloil are for installations at sea level and at elevations up to 1,000 feet. Reduce by 4% for each additional 1,000 feet above sea level. Deduct from shipping weight of burner with control set: less control set 3 lbs. less control set and primary control 9 lbs. Disc-turbulator combina tions for DH oil burner are as follows: Selection of nozzle: firing rate no. gph firing rate gph nozzle pray R1 .55-1.10 .55 to 1.25 60* -70* hollow R2 1.00-1.85 1 .65-1.10 or solid 2 .90-1.75 above 1.25 60'-70* solid 3 1.80 2.50 4 2.35-3.00 The correct disc-turbulator combination is furnished in stalled in the DH burner for nozzle size specified on order. Two-stage fuel unit is available for DH oil burners at added Trade Price $6.15 Controls and control sets are shown on page 35. Ordering Examples: 1 Oil Burner 1 DH-5 oil burner with No. 5 control set and 2.50 gph 70 solid nozzle for A-37M-WBT boiler-burner unit. 2. Oil Burner 1 DH-23 oil burner with No. 3 control set, 1.50 gph 60 solid nozzle, with pedestal. See page 56 Page 33 HH-11 02433 ZONE VALVE PACKAGE COMfORT COMPUTER Illustrated is Comfort Computer-Zone Valve Package AMERICAN a STANDARD HYDRONIC HEATING COMFORT COMPUTER MODEL 370(R) The American Standard exclusive and unique Comfort Computer is a solid state control which modulates the boiler water temperature in proportion to the number and length of heat demands. This control and zone valve pack age is especially designed for use with American Standard Boilers. Bene fits received are: improved comfort balance in living areas; reduction of wall streaking and expansion noises; and increased operating efficiency. The Comfort Computer controls the operation of the burner to slow down the response of the boiler temperature to calls for heat by a zone thermo stat. The control optimizes boiler water temperature and will not permit introduction of excessively hot water temperature to a zone. This control permits only those boiler water temperatures actually required by the heating system, yet permits high water temperatures during cold weather or during "pick-up" periods. The Comfort Computer is designed for Gas Boilers without tankless heaters; and is available in two models, the 370 and the 370R. The model 370 is for use with installed boilers using a solenoid gas valve only; the 370R is for use with all modern gas fired hydronic heating systems. ''Trade Prices are as follows: 370 ........................ $40.00 370R........................ $51.00 COMFORT COMPUTER - ZONE VALVE PACKAGE The Comfort Computer is available combined with the zone valve package factory mounted and wired. When ordering the complete package the designation of the zone valve package is added to that of the Comfort Computer, "Trade Prices are: 370R-2Z--$132.50 370R-3Z- $159.00 370R-4Z- $199.00 HYDRONIC ZONE VALVE PACKAGES No. Z*2 Package for 2 Zones No. Z-3 Package for 3 Zones No. Z-4 Package for 4 Zones 1 T822D thermostat 2 V8043F 44" zone valves soldered to manifold Less transformer Trade Price................................$82.00 2 T822D thermostats 3 T822D thermostats 3 V8043F 44" zone valves soldered to 4 V8043F 44 " zone valves soldered to manifold manifold Less transformer With transformer Trade Price ............................... $108.00 Trade Price.................. $148.00 Each zone valve package consists of 2, 3, or 4 Honeywell 44" zone valves soldered to manifold with 1J4" NPT inlet. Each zone valve is factory wired to low voltage leads for transformer and all end (auxiliary) switches are wired in parallel with a pre-wired harness. On-the-job wiring re quires 115 volt line to transformer, low voltage connections to circulator control, and low voltage wiring to each thermostat. If Vfe" system piping is used, a % x Vfe nominal copper to copper flush bushing can be soldered to any or all of the 44 " zone valves on the manifold. Flush bushing not furnished. One less thermostat is furnished than the number of zone valves per package. An additional thermostat is required when zone valve package is used on boiler furnished less thermostat. 40 VA transformer is not required when control L8148G or R8226B with power for 3 zone valves, is supplied with boiler. If 40 VA transformer is wanted with No. Z-2 or No. Z-3 Packages, specify on order and add to the above Zone Valve Pack age prices.............................................. .................. . Trade Price each $3.10 Honeywell V8043F 4 " Zone Valve sold separately HH-11 ^ See page 56 Page 34 .... . . T Trade Price each $21.75 02434 fSl AMERICAN IS STANDARD HYDRONIC HEATING CONTROL SETS, CONTROLS CONTROL SETS FOR BOILER-BURNER UNITS Control tet no. 1 steam no. 2 steam for boiler without domestic hot water boiler with year-round domestic hot water, tankless heater no. 3 gravity water no. 4 forced water boiler without domestic hot water, immersion control boiler without domestic hot water no. 5 A-3, A-5, FR-A-5 units only with year-round forced water domestic hot water no. 5-Z forced water A-3, A-5, FR-A-5 units only. (1 no. 5-Z set is required for each zone in addition to the first zone which is controlled by the no. 5 control set or equivalent.) control number T822D PA404A T822D PA404A L4006A T822D L4080B T822D L4081B T822D L8124C T822D R845A contents of control set description Thermostat Pressuretrol Thermostat Pressuretrol Aquastat operating control Thermostat Aquastat limit control Thermostat Aquastat limit and circulator control Thermostat Aquastat limit, reverse and operating control, circulator relay Thermostat Relay add to Trade Price of oil burner with basic control set $14.05 $11.00 $22.40 $26.20 number T822D TS822A T832A description thermostat, adjustable heater 0.18 to 0.8 amp. thermostat, millivolt thermostat, low voltage, manual T852A L4006A L4006E L4081B L4080D L4080B L6O06A L8124C Aquastat operating control Aquastat operating control; locks out on high limit setting; manual reset Aquastat limit and circulator control Aquastat limit control Aquastat limit control Aquastat operating and circulator Aquastat limit, reverse and operating control, circulator relay: line voltage burner control, horizontal L8124B L8124E L404C L604A L8148E L8048G millivolt burner circuit for gas with manuai-auto switch, vertical case low voltage burner circuit for gas, vertical case. Power for 2 zone valves Aquastat-relay combination, high limit and line voltage circulator control. horizontal case: Pressuretrol w/man. reset SPDT operating controller low voltage burner control for gas. Power for 2 zone valves. millivolt burner control for gas. Power for 3 zone valves. CONTROLS Trade Price number $ 6.B5 6.85 25.30 40.10 14.05 PA404A RA89A RA832A R845A R8226B R8182D 16.15 20.90 10.60 10.60 14.90 R8182E R8182F 39 3fl 29.40 31.80 R8184G 28.20 25.40 22.35 120320 description Trade Price Pressuretrol relay, SPST relay, DPST relay, DPST Transformer and circulator relay Aquastat-relay combination, high and low limit; providing room thermostat control of circulator; light sensing primary control, less cad cell; safety switch timing 70 seconds. For use with tankless. Aquastat combination, high limit; providing room thermostat control of circulator: light sensing primary control, less cad cell; safety switch timing 70 seconds. For use less tankless. Aquastat combination, high limit; providing room thermostat control of burner and boiler water temperature control of circulator; light sensing primary control, less cad cell; safety switch timing 70 seconds. For use less tankless. light sensing primary control, less cad cell: control number safety-switch timing-seconds gph R8184G1005 60 R8184G1021 30 R8184G1013 15 cadmium sulfide cell only 3 3-7 7-20 $16.10 15.35 19.35 19.35 10.60 54.50 50.00 44.60 30.00 32.95 36.80 2.20 22.35 See page 56 Accessories and controls included In this price book are for use in coniunction with American-Standard products Page 35 HH-11 02435 STOKER FIRED BOILERS WATER ANO STEAM ^AMERICAN IS STANDARD HYDRONIC HEATING A-7 STOKER FIRED BOILERS The standard for commercial and industrial building application. Available with or less jacket. Tested and equipped for 50 lbs. water working pressure WATER bolter number A-705-WC A-706-WC A-707-WC A-708-WC A-709-WC A-710-WC A-711-WC A-712-WC A-713-WC A-714-WC gross l=B=R output Mbh 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 l=B=R burner capacity lbs./hr. 95 111 131 151 172 194 215 236 257 278 * net l = B-R rating Mbh 753.0 880.0 1040.0 1196.5 1365.2 1530.4 1700.9 1867.8 2034.8 2201.7 a piping & pick-up factor 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 net rating sq. ft. water 5020 5866 6933 7978 9101 10202 11339 12452 13565 14678 unjacketed lacketed Trade Price approx. shipping weight Trade Price approx. shipping weight $1723.00 1879.00 2112.00 2334.00 2539.00 2752.00 2974.00 3155.00 3364.00 3557.00 4120 4775 5436 6017 6693 7370 7972 8610 9323 10013 $1827.00 2001.00 2249.00 2489.00 2710.00 2939.00 3179.00 3376.00 3603.00 3812.00 4292 4950 5619 6226 6908 7589 8233 8908 9593 10283 chimney size 16 x 16 x 28 16 x 16 x 30 16x20x36 16 x 20 x 42 16 x 20 x 45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80 STEAM boiler number A-705-SC A-706-SC A-707-SC A-708-SC A-709-SC A-710-SC A-711SC A-712-SC A-713-SC A-714-SC gross |=B=R output Mbh 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 l = B=R burner capacity lbs./hr. -95 111 131 151 172 194 215 236 257 278 net l = B = R rating Mbh sq. ft. steam * piping & pick-up factor 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 1816.8 1965.8 2707 3163 3738 4340 5013 5672 6328 6949 7570 8191 1.333 1.333 1.333 1.321 1.305 1.293 1.288 1.288 1.288 1.288 unjacketed Trade Price approx. shipping weight jacketed Trade Price approx. shipping weight chimney size $1723.00 1879.00 2112.00 2334.00 2539.00 2752.00 2974.00 3155.00 3364.00 3557.00 4121 4776 5438 6018 6697 7374 7973 8611 9324 10014 $1827.00 2001.00 2249.00 2489.00 2710.00 2939.00 3179.00 3376.00 3603.00 3812.00 4293 4951 5621 6227 6912 7593 8234 8909 9594 10284 16 x 16 x 28 16 x 16x30 16 x 20 x 36 16 x 20 x 42 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80 * The net f=r8 = R ratings shown are bated on piping and pick-up allowances listed in the column next to the ratings. American-Standard should be consulted before selecting a boiler for instolfations having unusual piping and pick-up requirements. Standard equipment: Water: ASME relief valve Pressure and temperature gauge Steam: ASME safety valve Steam gauge Gauge glass with trimmings Optional equipment: Steel pedestal bases for installation under the regularly furnished 12 inch cast iron base for greater base heights are available on order at the following added charges: section size 5 thru 7 8 thru 14 base height 8" 10" Trade Price $59.00 96.00 If steel pedestal base is not used, consideration should be given to the use of brick or masonry base as required. For additional optional equipment see page 33. Ordering Example: Stoker boiler for water with jacket with optional equipment 1 A-708-WC jacketed boiler, with $teel pedestal base. HH-11 See page 56 Page 36 02436 rS1 AMERICAN ksSTANDARD HYDRONIC HEATING A-7 HAND FIRED BOILERS Jacketed and unjacketed Tested and equipped for BO lbs. water working pressure hand fired boilers WATER AND STEAM WATER boiler number A-705-W A-706-W A-707-W A-708-W A-709-W A-710-W A-711-W A-712-W gross l= B=R output Mbh 1122 1298 1510 1708 1910 2108 2288 2456 net l = B=R rating Mbh A piping & pick-up factor 1 net rating sq. ft. water 625.4 744.3 894.0 1042.1 1202.0 1363.5 1518.2 1667.3 1.794 1.744 1.689 1.639 1.589 1.546 1.507 1.473 4169 4962 5960 6947 8013 9090 10122 11115 un|acketed "W Trade Price approx. shipping weight $1897.00 2064.00 2296.00 2533.00 2709.00 2895.00 3117.00 3280.00 4546 5270 6025 6679 7508 8170 8848 9565 jacketed Trade Price approx. shipping weight $2002.00 2185.00 2434.00 2688.00 2880.00 3084.00 3322.00 3501.00 4718 5545 6208 6888 7643 8389 9109 9863 chimney size 16 x 16x40 16 x 20 x 45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 65 20 x 24 x 70 24 x 24 x 75 STEAM boiler number A-705-S A-706-S A-707-S A-708-S A-709-S A-710-S A-711-S A-712-S gross l=B=R output Mbh 1122 1298 1510 1708 1910 2108 2288 2456 net l = B=R Mbh - sq. ft. steam A piping & pick-up factor 625.4 744.3 894.0 1042.1 1202.0 1363.5 1518.2 1667.3 2606 3101 3725 4342 5008 5681 6326 6947 1.794 1.744 1.689 1.639 1.589 1.546 1.507 1.473 unjacketed Trade Price approx. shipping weight $1897.00 2064.00 2296.00 2533.00 2709.00 2895.00 3117.00 3280.00 4561 5285 6036 6692 7521 8183 8861 9582 jacketed Trade Price approx. shipping weight $2002.00 2185.00 2434.00 2688.00 2880.00 3084.00 3322.00 3501.00 4733 5460 6219 6901 7656 8402 9122 9880 chimney size 16 x 16x40 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 65 20 x 24 x 70 24 x 24 x 75 AThe net l=B=R ratings shown are based on piping and pick up allowances listed in the column next to the ratings. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick up requirements. Standard equipment: Water: ASME relief valve Pressure and temperature gauge Automatic damper regulator Firing tools Steam: ASME safety valve Steam gauge Gauge glass with trimmings Automatic damper regulator Firing tools Ordering Example: Hand fired boiler for water with jacket with standard equipment: 1 A-706-W jacketed boiler See page 56 Page 37 HH-11 02437 HYDRONIC ASSEMBLING TOOLS ^AMERICAN kS STANDARD HYDRONIC HEATING PACKAGED HYDRAULIC ASSEMBLING TOOL: All necessary parts to assemble any American-Standard sectional boiler, except long tie rods, are shipped in one packing case; the long tie rods are furnished in their own wooden box. Total weight approximately 250 lbs. W Trade Price - $400.00 RADIANTRIM ASSEMBLY CLAMP. This tool is designed to draw Radiantrim cast iron baseboard sub-assembled panels or sections together with ease as per instructions included. Order through your American-Standard distributor. Trade Price each - $10.75 HEATRIM COPPER TUBE BENDING TOOL: This tool is specifically designed to bend riser tube connections for Model R Heatrim baseboard panels. Eliminates costly copper fittings. Com plete instructions for tool use included. Trade Price each -- $14.55 HEATRIM RISER HOLE TEMPLATE: This tool accurately and quickly lo cates riser hole locations for Model R Heatrim panels. Consists of template (two pieces), 8 ft. steel tape and com plete instructions. Trade Price each -- $2.90 ALUMINUM NIPPLE SETTING-HAMMER: --consists of a 2 )b. 2V6" diameter aluminum head and a 14" long hard wood handle. The aluminum head will not damage the nipple edges and per mits the heavy blows necessary to set nipples to the recommended depth quickly. Trade Price each -- $4.75 SECTION BUMPING BLOCK: -- made of a G" x G''x 18" hardwood block with a convenient steel handle for swinging the tool. Its purpose is to bump a sec tion onto the pre-set nipples of the previous section to the recommended depth, prior to pulling the section up. with one or two blows without damage to the section. Trade Price each -- $14.00 HH-11 'W See page 56 Page 38 02438 AMERICAN bd STANDARD HYDRONIC HEATING ELECTRA II PACKAGED ElECTRO-HYDRONIC BOILERS Completely packaged with deluxe two-toned brown and beige jacket. l'ie-wired for 240 volt, three wire, 60 cycle, single phase service. Designed and equipped with controls for forced circulation.. Tested and equipped for 30 lbs. water working pressure. PACKAGED BOILERS ELECTRIC WATER '.tfLrItSTTa4 E&Dor ELECTRIC CENTRAL MCATING BOILER WITH IHTESRAL LIMIT CONTROL E38076 NO 0000000 WATER ONLY packaged unit number EP-7 EP-10 EP-14 EP-17 EP-20 output watts 2,000 3,000 4,000 5,000 ~ 6,000 output btuh 6,826 10,236 13,648 17,060 20,472 amps 240 volts 8.34 12.50 16.65 20.81 25.00 Trade Price with standard equipment $193.00 193.00 193.00 193.00 193.00 approx. shipping weight 49 49 49 49 49 Ordering Example: EP Packaged Boiler with standard equipment: 1 EP'14 boiler Standard equipment T822D thermostat Circulator with piping Drain valve ASME relief valve Pressure and temperature gauge Expansion tank (diaphragm type) L4080D immersion limit control J. W. Hobbs M4440 low pressure switch Automatic air vent Output ratings based on 240 volts. Reduce output ratings for other voltages as follows: 230 volts, 8%; 220 volts, 16%; 208 volts, 25%. All electrical controls, circulator, expansion tank, pressure and tempera ture gauge, automatic air vent, and drain valve, are factory installed and wired. Thermostat and relief valve shipped in accessory bag fastened inside boiler carton. Zone valve packages are available for water boilers. For details and Prlces. see PaSe 34 See page 56 Page 39 HH-11 02439 PACKAGED BOILERS ELECTRIC WATER ^AMERICAN La STANDARD HYDRONIC HEATING "ELECTRA" EP PACKAGED ELECTRO-HYDRONIC BOILER For the ultimate in modern electric heating, choose the "Electra.'' a completely assembled pre-wired, hydromc heating cast iron boiler Designed for ultra-safe operation and equipped with controls for forced circulation. Attractive two-toned brown and beige jacket completely conceals all components including the circulating pump and expansion tank Rugged boiler shell is tested and equipped for 30 lbs water working pressure and unit is ar ranged for 240 volt, three wire. 60 cycle, single phase service WATER packaged boiler number number of elements output watts output btuh amps <s> 240 VOltS EP-34 2 10,000 34,130 41.7 EP-51 3 15.000 51,195 62.4 EP-68 4 20,000 68,260 83.2 EP-82 5 24.000 81.912 100.0 ELECTRIC CENTRAL HEATING 600. WITH '"ECRAL limit control 118076 No <*, , 'Trade Price with standard equipment $387.00 400.00 416.00 431.00 approx. 1 chipping --4| weight % 98 99 100 102 Standard equipment T822D thermostat AT72D low voltage transformer R8154 sequencing control L4008J adjustable immersion type limit control Allen-Bradiey 836CP11-HKAZS High pressure switch with EP-68 and] EP-82 only J. W. Hobbs M4440 Low pressure switch iy4" circulator Expansion tank (diaphragm type) Automatic air vent ASME Relief valve Pressure and temperature gauge Drain valve Ordering Example: EP Packaged Boiler with standard equipment 1 EP-68 boiler HH-11 See page 56 Note: EP Electric Boilers are shipped with jacket and all controls (except thermostat and relief valve) factory installed and wired. Circulator and expan* ! sion tank are factory installed and enclosed in the jacket. Thermostat, relief valve and nipple, and circulator flange and gasket shipped in accessory bag ^ fastened inside boiler carton. Output ratings based on 240 voltss>,. Reduce output ratings for other voltages as follows: 230 volts, 89 ; 220 volts, 16%; 208 volts, 25%. Optional equipment Sequencer Package: Available for field installation on EP-68 and EP-82 i Boilers in addition to regularly furnished sequencing relay. Package contaM* j all necessary equipment and instructions for the installation of one or two (EP-82) 24A11-4 Sequencers) which will provide a 45 second currJr**J delay between the third and fourth elements of the EP-68 or between third, fourth and fifth elements of the EP-82 Standard R8154 relay provide*^ a 1/120th of a second (^ cycle) current delay between each element. Sequencer Package Trade Price EP-68 $11.13 EP-82 21.47 Note: Zone valve packages are available for water boilers. For details *8*^ prices, see page 34. Page 40 02440 ^AMERICAN IS STANDARD HYDRONIC HEATING HEATRIM PANELS MODEL R HEATRIM PANELS SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS (For Model R-750A and >/2" Model R-500-A Panels) For comparative and estimating purposes only. DESCRIPTION ordering number packaged per MODEL R-750-A COMPLETE ASSEMBLED R-750A2 UNITS (Single Pack) Packed in a "pull tape" box, R-750-A3 includes 1 each of front and R-750-A4 back panel, element. damper, necessary support R-750A5 brackets, slide cradles and 1 set joining pieces. Finished with R-750 A6 white prime paint. All factory R-750-A7 assembled. Box Color Coded--Red R-750-A8 Ordering Example: 1-box R-750-A4 per lineal foot 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length Trade Price approx. shipping weight $ 2.09 4.18 6.2? 8.36 10.45 12.54 14.63 16.72 5 7 9 12 13 16 18 MODEL R-500-A COMPLETE ASSEMBLED UNITS (Single Pack) Packed in a "pull tape" box, includes 1 each of front and back panel, element. damper, necessary support brackets, slide cradles and 1 set joining pieces. Finished with white prime paint. All factory assembled. Box Color Coded-Green Ordering Example: 1--box R-500-A3 R-500-A2 R-500-A3 R-500A4 R-500-A5 R-500-A6 R-500A7 R-500A8 per lineal foot 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length 1.98 3.97 5.95 7.94 9.92 11.91 13.89 15.88 5 7 9 11 14 15 18 MODEL R ENCLOSURE ONLYASSEMBLED (Single Pack) Packed in a "pull tape" box, includes 1 each of front and back panel, damper, necessary support brackets, slide cradles and 1 set joining pieces. Finished with white prime paint. All factory assembled. Box Color Coded--Black Ordering Example: 1-box R-3-A R-3-A R-4-A R-5-A R-6-A R-7-A R-8-A R-10-A R-12-A per lineal foot 3 ft. length 4 ft. length 5 ft- length 6 ft. length 7 ft. length 8 ft. length 10 ft. length 12 ft. length 1.02 3.06 4.07 5.09 6.11 7.13 8. IS 10.19 12.22 6 8 10 11 13 15 17 19 MODEL R ENCLOSURES ONLYUNASSEMBLED (Bulk Pack) Packed in a "pull tape" box, includes 3 sets of front and back panels, dampers with clips, necessary support brackets, slide cradles and 2 sets of joining pieces. Finished with white prime paint. Unassembled. Box Color Coded--Blue Ordering Example: 1-box R-5-B R-3-B R-4-B R-5-B R-6-B R-7-B R-8-B R-10-B R-12B per lineal foot three 3' lengths three 4' lengths three 5' lengths three 6' lengths three T lengths three 8' lengths three 10' lengths three 12' lengths .91 8.22 10.96 13.70 16.44 19.18 21.92 27.41 32.89 16 21 26 30 35 40 48 58 See page 56 Page 41 HH-11 02441 aa Is M 1= aS. Io> o c3 02442 1.59 1.63 rH rH rH H r1* rH .222. 02443 Net P rice HEATRIM ELEMENTS AND ACCESSORIES IAMERICAN kSiSTANDARD HYDRONIC HEATING MODEL R HEATRIM ELEMENTS AND ACCESSORIES l nriii|ininm -- DESCRIPTION E-750 (V tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths Ordering Example: 1--bundle E-750-3 ordering number E-750-3 E-750-4 E 750 5 E-750-6 E-750-7 -750-8 packaged per per lineal foot Trade Price I 1.12 approx. shipping weight six 3' lengths six 4' lengths six 5' lengths six 6' lengths six 7' lengths six 8' lengths 20.22 26.96 33.71 40.45 47.19 53.93 9 12 16 18 22 25 E-5O0 W tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths. Ordering Example: 1-bundle E-500-4 E-500-3 E-500-4 E-500-5 E-500-6 E-500-7 E-500-8 *per lineal foot $ 1.02 six 3' lengths six 4' lengths six 5' lengths six 6' lengths six T lengths six 8' lengths 18.33 24.44 30.56 36.67 42.78 4B.89 8 10 12 16 19 21 ACCESSORIES End Cap-3" wide-Right Hand End Cap-3" wide-Left Hand Valve Enclosure--I" wide--Right Hand Valve Enclosure-4" wide--Left Hand Valve EncJosure-6" wide--Right Hand Valve Enclosure--6" wide--Left Hand Inside Cornor-hinged front and top--90 Inside Corner-back piece--90 Inside Cornor-one-piece front and top-1350 /45c Inside Corner-back piece-1350/450 Outside Corner-90-' Outside Corner-I35V45 Filler piece set-7" wide Filler piece set-14" wide Wall End Pieoe-3" wide Return tubing wire bangers Connecting tubing wire hangers Joining piece set--" wide Extra support brackets with slide cradles and damper clips Tube bending tool NOTE: Finished with white prime paint. RA-ECR-03 RA-ECL-03 RA-VER-04 RA-VEL-04 RA-VER-06 RA-VEL-06 RA-ICF-90 RA-ICB-90 RA-ICF-45 RA-ICB-45 RA-OCF-90 RA-OCF-45 RA-FPS-07 RA-FPS-14 RA-WEP-03 RA-WHR-50 RA-WHS-50 RA-JPS-02 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 5 box of 10 bag of 50 bag of 50 box of 20 sets RA-SBP-20 box of 20 sets For comparative and estimating purposes NOTE: Add 25rV to pnoe when ordering in less than quantities indicated above. 8.40 8.40 11.55 11.55 17.64 17.64 10.50 3.36 10.50 3.20 12.60 14.70 8.50 6.50 4.41 2.10 2.21 5.46 7.40 14.55 4 4 9 9 10 10 3 4 2 2 5 3 9 9 4 -- -- 5 5 HH-11 See page 56 Page 42 02444 rSl AMERICAN iS STANDARD HYDRONIC HEATING HEATRIM PANELS MODEL SS HEATRIM PANELS, ELEMENTS AND ACCESSORIES Commercial baseboard panels designed for hotels, motels, apartments, hospitals, schools and churches The SS Heatrim is ideal for residential "hard to heat" areas such as bathrooms, hallways, etc SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS (For yt" Model SS75 and 1" Model SS-100 Panels) DESCRIPTION ordering number packaged per ^Trade Price approx. hipping weigh! MODEL S5-75 COMPLETE UNITS (Dual Pack) Box includes 2 each of front and back panel, % " element, damper, necessary support brackets and slide cradles and 1 joining piece set. Finished with off - white prime paint. Ordering Example: 1-box SS-75-6 SS-75-2 SS-75-3 SS-75-4 SS-75-5 SS-75-6 SS-75-7 SS-75-8 per lineal foot $ 3.20 Two 2 ft. lengths Two 3 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft lengths $12.80 19.20 25.60 32.00 38.40 44.80 51.20 14 20 26 33 39 46 52 MODEL SS-100 COMPLETE UNITS (Dual Pack) Box includes 2 each of front and back panel, 1" element, damper, necessary support brackets and -slide cradles and 1 joining piece set. Finished with off - white prime paint. Ordering Example: 1--box SS-100-5 SS-100-2 SS-100-3 SS 100-4 SS-100-5 SS-100-6 SS-100-7 SS-100-8 per lineal foot S 3.55 Two 2 ft. lengths Two 3 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths 14.20 21.30 28.40 35.50 42.60 49.70 56.80 14 20 26 33 39 46 52 MODEL SSI-75 COMPLETE UNITS (Single Pack) Box includes 1 each of front and back panel, % " element, damper, joining piece set and necessary support brackets and slide cradles. Finished with off-white prime paint. Ordering Example: 1-box SSI -75-7 SSI-75-2 SSI-75-3 SSI-75-4 SSI-75-5 SSI-75-6 SSI-75-7 SSI-75-8 per lineal foot S 3.35 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length 6.70 10.05 13.40 16.75 20.10 23.45 26.80 7 11 14 18 21 25 28 MODEL SSI-100 COMPLETE UNITS (Single Pack) Box includes 1 each of front and back panel, 1" element, damper, joining piece set and necessary support brackets and slide cradles. Finished with off-white prime paint. Ordering Example: 1-box SSI-100-6 SSI-100-2 SSI-100-3 SSI-100-4 SSI-100-5 SSI-100-6 SSI-100-7 SSI-100-8 per lineal foot S 3.70 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft length 7.40 11.10 14.80 18.50 22.20 25.90 29.60 7 11 14 18 21 25 28 For comparative ana estimating purposes only See page 56 Page 43 HH-11 02445 HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES AMERICAN Si STANDARD HYDRONIC HEATING MODEL SS HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES Commercial baseboard panels designed (or hotels, motels, apartments, hospitals, schools and duirrhc I he SS Hcairim is ideal for residential "hard to heat" areas such as bathrooms, hallwavs, etc DESCRIPTION pockogid per approx (hipping weight MODEL SS ENCLOSURES ONLY (Bulk Pack) Box includes 4 each of front and back panel, damper, necessary support brackets, connecting tube wire hangers and 3 joining piece sets. Finished with off white prime paint. Ordering Example: 1--box SS-B MODEL SSI ENCLOSURES ONLY (Single Pack) Box includes 1 each of front and back panel, damper, joining piece set, necessary support brackets and connecting tube wire hangers. Finished with off white prime paint. Ordering Example: 1-box SSI-6 ES-75-8 (% " tube) ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of %" element and necessary slide cradles. Ordering Example: 1-box ES-75-B ES-100-8(1" tube) ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of 1" element and necessary slide cradles. Ordering Example: 1-box ES-100-8 SS-3 SS-4 SS-5 SS-6 SS-7 SS-8 SSI 3 SSI-4 SSI-5 SSI-6 SSI-7 SSI-8 ES-75-8 ES-100-8 per lineal toot $1.65 Four 3 h lengths Four 4 ft lengths Four 5 ft lengths Four 6 ft, lengths Four 7 ft. lengths Four 8 ft lengths $19.80 26.40 33.00 39.60 46.20 52.80 per lineal foot $1.85 3 ft length 4 ft. length 5 ft length 6 ft. length 7 ft length 8 ft length $ 5.55 7.40 9.25 11.10 12.95 14.80 per lineal foot SI.55 Eight 8 ft. lengths $99.20 per lineal foot $1.90 E ight 8 ft. lengths $121.60 31 42 52 63 73 84 11 14 18 22 25 29 42 48 ACCESSORIES R. H. 2V6" End Covers (Short of Floor) .............................................. .. . L. H. 2VL" End Covers (Short of Floor) .................................................. . . R. H. 2%" End Covers (Extend to Floor) .............................................. ... L. H. 2hi" End Covers (Extend to Floor) ............................................... R. H. 6" End Covers (Short of Floor)....................................................... . . L. H. 6" End Covers (Short of Floor)....................................................... R. H. 6" End Covers (Extend to Floor) ................................................... L. H. 6" End Covers (Extend to Floor)................................................ Inside Corner Covers .................................................................................... . . R. H. Valve Enclosures with hinged access door................................. L. H. Valve Enclosures with hinged access door................................... R. H. Valve Enclosures with hinged access door & knockout for mainless installation......................................... ... L. H. Valve Enclosures with hinged access door & knockout for mainless installation .................................................. Wall End Pieces (Short of Floor) .. .... Wall End Pieces (Extend to Floor)..................... Outside Corner Covers.................................. 14'' Filler Pieces.................... ......... 2" Joining Piece Sets ... ............ Support Brackets, Slide Cradles, Damper Clips Return Pipe Hangers Damper Joiners Connecting Tube Hangers.................... SS-ECR-25S SS-ECL-25S SS-ECR-25F SS-ECL-25F SS-ECR-06S SS-ECL-06S SS-ECR-06F bb-tLiL-Ut)F SS-IC-90 SS-VER-06H SS-VEL-06H SS-VERK-06H SSVELK-06H SS-WEP-25S SS-WEP-25F SS-OC-90 SS-FPS-14 SSJPS-02 SS-SBP-24 SS-WHR-50 SS-DJ-50 SS-WHS-50 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 1 2 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 4 Box of 6 Box of 24 Box of 24 Box of 50 Box of 50 Box of 50 $ 11.55 11.55 14.70 14.70 15.75 15.75 17.85 17.85 7.35 31.50 31.50 32.00 32.00 4.75 5.25 12.60 12.60 5.30 10.50 5.25 3.95 6.30 8 8 9 9 7 7 7 7 5 13 13 13 13 4 4 5 14 4 10 1 1 3 for comparohvt ond ejtimotmg purpose* only * Note Add 25% to price when ordering in less than quantities indicated above HH-11 Page 44 See page 56 a 02446 ,_|AMERICAN Si STANDARD HYDRONIC HEATING RADIANTRIM BASEBOARD PANELS SEE CURRENT LITERATURE FOR APPROVED > l = B=R STEAM AND HOT WATER RATINGS BASEBOARD PANELS RADIATORS RADIATOR ACCESSORIES Steam Rating per lineal foot 3.4 sq ft per lineel foot Trade Price- $5.39 per square foot $1.58 Model 10 Radiantrim Panel lengths (2V4 ft to 30 ft) are made up from the following sections: 1 Vi ft Left hand end section 1 ft Right hand end section 2 ft Left hand end section 2 ft Right hand end section 2 ft Center section Assembly length with legs and tappings at each end: 1V4 ft Double end section 2 ft Double end section For purpose of estimating shipping weights, use 43/ pounds per sq. ft.. 16.15 pounds per Imeal foot Model 10 Accessories ^Vhc width 6 tube 4, 6 tube 4 tube height, Inches sq ft per section Trade Price per sq ft 32 3.7 25 2.0, 3.0 19 1.6 $2.40 1.88 2.00 Arco Radiators are regularly furnished with two and onehalf inch (2 Vi") legs. Available on Special Order with four and one-half inch (4H") legs, or without legs--Price on application. Arco Radiators sold only in even number of sections up to a maximum of 56 sections. For purpose of estimating shipping weights, use 4^ pounds per sq. ft. Ordering Example: 1-12 Section 25" Arco 4 Tube Vi x Vi SUNRAD RADIATORS Extension Panel with 3 Brackets Two 6 ft lengths per box............................................ $17.72 Extension Panel Retaining Bracket........................ .50 Extension Panel Cover Strip................................... .72 I Assembly Clamp........................v............................... 11.83 Important: Increase size 5% for re cessed installation--air space top and sides, V\" at back. Increase size 15% for tightly recessed installationno clearance top or sides, V\" air space at back. Short-Compression Corner Connection................ 2.86 Long-Compression Corner Connection................. 3.85 typ. sq ft per section Trade Price per sq ft Retaining Block ......................................................... Adjustable Leg ........................................................... .21 .30 M 5 x 20 2.25 $2.30 Tie Bolt ...................................................................... .11 Sunrad Radiators are regularly furnished with legs and two- These items are regularly furnished as required with Model 10 Ra diantrim Panels and Accessories. Prices are shown for repair or re placement purposes. Packed in quantity of 10 per box ^'phm (Available only in this minimum quantity) par box or 10 pipe inside connections. Available on special order with onepipe connections, outside tappings or without legs--Price on application. Sunrad Radiators sold in even number of sections from 4 to Inside Corner Cover .................................................. $17.60 Extended Inside Corner Cover................................... 31.90 30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections. Outside Corner Cover.................................................... Valve Enclosure (all R.H. or L.H.) ............................ End Box (all R H or L.H.) ........................................ 10" Plain Extension Piece......................................... Extension End Piece (all R.H. or L.H.) ...................... Ordering Example: 1--7 ft. Model 10 Radiantrim Panel. 1-Bok of Model 10 Right Hand Valve Enclosures. 23.65 24.20 13.20 15.38 9.46 Sunrad Grilles Inlet--Stamped Lattice Type per section $0.29 Special No. 16 Gauge with Locking Device ....................... Price on application For purposes o/ estimating shipping toeights, use 6 pounds per sq it Ordering Example: 1-10 Section M5 x 20 Sunrad T-4 Vi i ^ 1--Type M Sunrad Grille for above. EXTRA RADIANTRIM ACCESSORY BAGS Bag No. For Trade Price 0 Double Leg Section 2%'-6' Panel Length 2 6%'-12' Panel Length 3 12 VS'-18' Panel Length 4 18%'-24' Panel Length 5 24V4--30' Panel Length $ .95 1.19 2.54 3.78 4.97 6.39 Sufficient quantities of these bags are regularly furnished aswith Radiantrim Panels. Prices shown are for extra bags may be required. RADIATOR ACCESSORIES Trade Price each Arco Brackets for 4 and 6 tube, with Wail Plate ... $1.21 Arco Radiator Pedestals '/?' and 1" ....................................................... 59 Sunrad Brackets Nipples, Plugs, Bushings, etc. 1", 1%", IVi" Plugs, Bushings V, 1", IVi" Slip Nipples..................................................................... .32 .32 1/8" Air Vent Plugs ... Radiator Rod Nuts . ... .01 Radiator Rods per section .01 ADove items available for use only with our Radiator products. .02 'W See page 56 Page 45 HH-tl *47 .92 02447 convectors ____ _ ^AMERICAN KSiSTANDARD HYDRONIC HEATING MULTIFIN CONVECTORS TYPE K - STOCK MODEL - FREE STANDING Expanded prices For use on two-pipe steam and hot water systems only. CdblASf length in<hsi No. 4 depth (4Vi" cabinet) nil M. K ft Mlpm #PPM. chipping waifht Trod* frit* 20" cabinet height No. 6 depth (6 >4" cabinet) unit a. H 1 ufpuf pprai. shipping weight Trod* frit* No. 8 depth (8Vi" cabinet) unit it. 10 ft output pprat. shipping wsight Tradt flics No. 10 depth (10*/," cabinet) s It autpvt oppros. ihipping Trade watghf frit* 20 420-20 24 424-20 28 32 36 40 44 48 56 64 10.6 13.0 18 20 $21.85 23.20 620-20 14.9 624-20 18.4 628-20 22.0 632-20 25.5 636-20 29.0 64C-- 32.5 644-20 36.1 648-20 39.6 656-20 664-20 46.7 53.8 21 24 27 29 33 34 37 40 45 52 $24.25 26.20 28.20 30.20 832-20 32.15 836-20 34.10 840-20 36.10 38.10 848-20 42.05 856-20 46.05 864-20 31.7 36.0 40.4 49.2 58 0 66 9 33 37 39 46 51 59 $33.65 36.05 1036-20 38.50 1040-20 45.5 51.2 42 48 43.45 1048-20 48.40 1056-20 53.35 1064-20 62.3 73.4 84.5 52 5B 64 $41.40 44.55 50.80 57.00 63.20 24" cabinet height 20 420-24 24 424-24 28 428-24 32 36 40 44 48 56 64 12.1 14.9 17.8 20 22 25 $22.70 620-24 17.2 23 24.25 624-24 21.2 26 25.85 628-24 25.4 30 632-24 29.5 33 636-24 33.5 35 640-24 37.6 38 644-24 41.7 42 648-24 45.7 44 656-24 53.9 50 664-24 62.2 57 $25.55 27.75 30.10 32.45 832-24 34.65 836-24 36.95 840-24 39.25 41.50 848-24 46.10 856-24 50.75 864-24 35.6 40.5 45.5 55.4 65.2 75.3 38 40 44 50 55 63 $35.85 38.60 1036-24 41.40 1040-24 49.0 55.2 45 52 46.90 1048-24 52.40 1056-24 56.05 1064-24 67.1 79.0 92.0 62 64 71 $43.35 46.80 53.50 60.15 66.85 32" cabinet height 20 24 28 32 36 40 44 48 56 64 620-32 18.7 29 624-32 23.1 32 628-32 27.7 36 632-32 32-2 40 636-32 36.5 43 640-32 41.0 48 644-32 45.4 56 648-32 49.8 58 656-32 58.7 67 664-32 67.8 71 $26.35 28.85 31.40 33.90 832-32 40.9 36.35 836-32 465 38.85 840-32 41.30 52.2 43.80 848-32 63.6 48.75 856-32 74.9 53.85 864-32 86.5 45 48 56 65 73 76 $38.80 41.95 1036-32 45.15 1040-32 55 0 61.9 54 59 51.50 1048-32 75.3 57.85 1056-32 88.7 64.35 1064-32 102.2 69 76 84 $46.70 50.55 58.05 65.55 73.15 Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 45. Note: For stock model cabinet extras, see page BO. Ordering Example: l-K-636-32 Multifin. HH-11 See page 56 Page 46 ^AMERICAN Si STANDARD HYDRONIC HEATING CONVECTORS Type K (Stock Model) Type F (Special Service) Type S Type FS MULTIFIN CONVECTORS Combination Price: The actual output in square feet of catalog rating-Steam (215"?.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination. The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered. SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS type description 'W Trad* Price 09 r Q ft unit extra charge Stock Model K Floor Type--free standing.............................................................. $0.56 $15.90 Note: Price shoum for estimating purposes only. For expanded prices, see page 16. For cabinet extras, see page 50. Special Service F FG w FS - FSG S FR FRG FRGB PR PRG PRGB Floor Type-free standing.............................................................. Floor Type--free standing-inlet grille...................................... Wall Hung--flat top.......................................................................... Free Standing--sloping top............................................................ Free Standing-sloping top-inlet grille.................................... Wall Hung-sloping top.................................................................. Fully recessed-^," beveled edges.............................................. Fully recessed--^*" beveled edges-inlet grille...................... Fully recessed-^*" beveled edges-inlet grille with bottom overlap and liner bottom............................................ Partially recessed-1 W, 2 W', 3", 5" flanged edges .......... Partially recessed--1*", 2Vfe", 3", 5" flanged edges-inlet grille ................................................................................................ Partially recessed--1V&", 2Vfc", 3", 5" flanged edges-inlet grille--with bottom overlap and liner bottom.................... $0.67 .67 .67 .63 .63 .63 .68 .68 .68 .70 .70 .70 $19.28 22.15 19.28 20.34 23.22 18.32 20.34 23.22 25.56 23.54 26.31 33.76 TypeW (Typo FRGB shown) See page 56 Note: For cabinet extras, see page 50. For estimating purposes only, the following approximate shipping weights per sq ft may be used for Multifln convectors: Multifin stock model -- 1.13 pounds. Also see page 46. Multifin cabinets (less element) -- 1% pounds. Multifln cabinets (with element): Types F, FR, PR - 1% pounds. Types FS, W -1 % pounds. Type S -1 Vi pounds. Ordering Examples: Stock Model Multifin with an optional feature: 1 K-840-24 Multitin with Metal Trim Strips. Special Service Multifin with an optional feature: 1 PR-640-32-2Vi Flange, Multifin with Knob Damper. Pa047 HH-11 02449 CONVECTORS f51 AMERICAN IS STANDARD HYDRONIC HEATING MULTIFIN CONVECTORS - continued convector length Inches 20 24 28 32 36 40 44 48 56 64 Elements only (when sold less cabinets) -- two-pipe steam or hot water No. 4 depth No. 6 depth No. 8 depth No. 10 depth unit no. approx. shipping weight Trade Price unit no. approx. shipping weight Trade Price unit no. approx. shipping Trade weight Price unit no. approx. shipping weight Trade Price 420 8 $12.60 620 13 $15.45 820 15 $18.25 1020 21 $21.00 424 10 13.65 624 16 16.95 824 19 21.10 1024 26 24.35 428 432 436 12 14 16 14.70 628 19 15.80 632 22 17.15 636 25 18.45 828 23 19.75 832 27 21.25 836 31 22.60 24.60 26.80 1028 1032 1036 31 36 41 27.15 29.80 32.90 440 444 448 18 20 22 18.45 640 28 19.70 644 31 20.85 648 34 23.05 24.60 26.30 840 844 848 35 39 43 28.70 30.85 32.85 1040 1044 1048 46 51 56 35.50 38.00 40.40 456 464 26 30 23.20 25.65 656 664 40 46 29.30 32.65 856 864 51 59 36.70 40.65 1056 1064 66 76 45.00 50.50 Not*: Elements only are furnished less floor supports. Multifin elements for special one-pipe steam header appiicatlon-not available. Ordering Example: 1-420 Multifin Element only--no cabinet. Ratings: Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-4? and amendments and said ratings have been approved by the Convector Rating Committee. Standard Cabinets: Standard cabinets are furnished in prime painted sheet steel--reinforced. No. 18 gauge front and No. 20 gauge back, ends and top, rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors as cur rently catalogued. MINIMUM CABINET HEIGHTS WITH DAMPERS FOR MULTIFIN AND ARCO CONVECTORS Type cabinet F, FG W FS. FSG S FR.FRG.FRGB PR. PRG, PRGB Multifin 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths Arco Cast Iron 24" For all depths 24" For all depths 24" For all depths 24" For #4, #6, #8 depths-32" For it 10 depth 20" For all depths 20" For all depths Cabinet heights shown for types W and S are nominal heights, actual heights are 5" less. Cabinet heights for Arco Cast Iron convectors applicable to X-4 (underneath) connections only. hh-11 "W See page 56 Page 48 02450 AMERICAN LS STANDARD HYDRONIC HEATING CONVECTORS ARCO CONVECTORS SPECIAL SERVICE LINE when sold in combination with standard cabinets COMBINATION PRICE: The actual output in square feet of catalog rating-Steam (215F> obtained with the cabinet heights furnished deter mines the price of convectors and cabinets sold in combination The total price of each order equals the amount of catalog square feel ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS cabinet type description Trade Price per sq ft unit extra charge F Floor Type-free standing $2.17 FG Floor Type-free standinginlet grille .......................... 2.17 w Wall Hung-fiat top ... 2.17 FS Free Standing-sloping top 2.17 FSG Free Standing-sloping top- inlet grille ................ 2.17 S Wall Hung--sloping top 2.17 FR Fully recessed-%6" beveled edges .......................................... 2.17 FRG Fully recessed--beveled edges-mlet grille................ 2.17 FRGB Fullv recessed-^" beveled edges-inlet grille with bottom overlap and liner 2.17 $26.94 30.23 26.94 28.34 31.50 28.34 26.94 30.23 32.89 cabinet type description PR Partially recessed-1 Vi". 2Vs", 3". 5" flanged edges . . . . Trade Price per sq ft unit extra charge $2.25 $31.12 PRG Partially recessed-1 xk", 21,a,\ 3". 5" flanged edges-inlet grille ...................................... 2.25 34.28 PRGB Partiallv recessed-1 V2". 217". 3". 5" flanged edges-inlet grille--with bottom overlap 2.25 42.38 Standard Cabinets are furnished in: Prime painted sheet steel-reinforced, No 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors listed m cur rent literature. For illustrations of cabinets, see page 4 7 For cabinet extras, see page 50. Ordering Example: l-F-458-20 Arco Convector Unit X-4 vA y \2 For estimating shipping weights of Arco Convector Units use: IVz pounds per square foot for cabinet portion 3Vz pounds per square foot for element portion. ARCO CONVECTOR -- steam or wafer ELEMENTS ONLY (when sold less cabinets) convector length Inches 18 23 28 33 38 43 48 53 58 63 No. 4 33,4" depth unit no. approx. shipping ^Trade weight Price 418 39 $20.11 423 50 26.06 428 61 31.88 433 72 37.77 438 83 43.59 443 94 49.34 448 105 55.10 453 117 60.97 458 128 66.79 463 139 72.74 No. 6 55/8" depth unit no. approx. shipping ^Trade weight Price 618 57 $ 29.67 623 73 38.27 628 90 46.87 633 106 55.66 638 123 64.26 643 139 72.93 648 146 81.47 653 172 90.07 658 189 98.74 663 206 107.47 No. 8 7%" depth unit no. approx. shipping vTrade weight Price No. 10 9i/2" depth unit no. approx. shipping ^Trade weight Price 818 71 $ 37.39 1018 84 $ 45.03 823 92 48.39 1023 no 58.26 828 113 59.40 1028 136 71.60 833 134 70.28 1033 162 84.76 838 155 81.09 1038 188 98.11 843 176 92.09 1043 213 111.32 848 197 103.10 1048 238 124.67 853 218 114.10 1053 264 138.01 858 239 125.05 1058 289 151.24 863 260 135.99 1063 314 164.39 Ordering Example: 1--418 Arco Cast Iron Element only-No Cabinet X-4 Vi x V2 Arco Convectors in lengths and depths indicated above are Standardized Sizes when sold with or without cabinets For sizes not listed above-price on application See page 48 for minimum cabinet heights with dampers. "W See page 56 Page 49 HH-11 02451 CONVECTORS (AMERICAN STANDARD HYORONIC HEATING CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS CABINET EXTRAS-STOCK MODEL MULTIFIN ONLY ITEM DESCRIPTION DAMPER METAL TRIM STRIPS Knob Operated Damper Package.................................... ............ each For recessing stock models only 20" to 36" long................................................................ . .. each 40" to 64" long .............................................................................. .............. each GRILLE AIR VENT Snap-on Inlet Grille for Stock Models Only .................... Air chamber with extended tube, manual vent ................ Air chamber with Dole No. 20JR auto-vent...................... 'Note: Items also available for special service Multifin. 'W Trade Price $ 5.50 9.45 12.10 4.20 5.35 5.35 SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS (Prices indicated are for standard catalogued sizes only) ITEM DESCRIPTION "W Trade Price DAMPER Knob or Institutional Type .................................................................... each % 6.55 ACCESS DOOR TAMPER PROOF SCREWS CAM LOCKS INSULATION In standard locations 1, 2, 3, 4, 7 or 8 as shown in current literature. -- Hinged type with Slotted Head operator .............................................. each Hinged type with Allen Head operator .................................................. each Note- Access doors in other than standard locations 6.55 7.80 Price on application Phillips or Allen Head screws (other than standard Slotted Head) per cabinet 1.05 Allen Head Cam Locks (Allen Keys Not Furnished)- Types F, FG. FS and FSG........................................................ per cabinet Types S and W (Multifin Only) .................................. .. per cabinet TyT FRJ,,RG' PR' PRG' PR,GB10ver4488' . ` `' per cablnel Note: Additional charge per order $5.20 5.40 5.40 23.80 29.80 Vz " Celotex or Fibreglas on outside of cabinet Back only...................................................................................... per cabinet Back, ends and top......................................................................................... percabinet Vz" Millboard on outside of cabinet Back only........................................................................................ per cabinet Back, ends and top........................................................................................ percabinet 11.10 13.70 26.00 36.95 SOUND DEADENING MATERIAL Approx. Vfe" thick--inside front panel only................................ per cabinet 11.00 SEALING STRIP For standard length FR, FRG and FRGB cabinets only (V4" x Polyurethane) ........................................................ per cabinet -4.60 STIFFENER All fronts 48" and longer, or 32" and higher have stiffening channel spotwelded to inside front in horizontal position at no additional charge. Stiffening channel on fronts other than standard ............................................................................................. per cabinet 1.55 METAL TRIM STRIPS For recessing Types F and FG Multifin convectors only Cataloged heights and lengths up to 36"............................................ each Cataloged heights and lengths 40" to 64".......................................... each 10.60 13.05 END POCKETS Specify right or left hand side 4" end pocket with No. 18 gauge vertical baffle............ per end pocket 8" end pocket with No. 18 gauge vertical baffle............ per end pocket 5.90 9.45 KNOCKOUTS Are optional-Furnished only on request Price on application HEAVIER GAUGE CABINETS HH-11 See page 56 Trade Price per square foot of cabinet output Front Only No. 18 gauge........................,............... No. 16 gauge........................................ No. 14 gauge......................................... $-- .07 .14 Page 50 Liners Only $.07 .09 not available 02452 ^AMERICAN csJSTANDARD HYDRONIC HEATING general INFORMATION BOILER RATINGS The pc: 1 -- B -- K boiler ratings represent the maximum net loads that may be connected to the boilers. The net I -- B = R steam ratings are based on a piping and pickup allowance of 1 333 except where an appropriate piping and pickup column shown. Steam sq. ft. ratings are based on 240 Btuh per sq ft. The net I --B=:R water ratings in Mbh are based on a piping and pickup factor of 1.15. Water sq. ft. rating' are based on 150 Btuh (17CF water) per sq. ft. For installations having unusual piping and pickup requirements, AmericanStandard should be consulted before selecting a boiler. For forced hot water heating systems where the boiler and piping are within the area to be heated, the boiler may be selected on the basis of its gross output Sufficient radiation must be installed for the requirement' of the building to be served. In order to select the proper size bode:, calculate the heat loss of the building, then divide thm figure by 1.000 to get the heat loss expressed in Mbh .Select a 'team or water boiler which has a net I = B=;R Mbh rating equal to or greater than this figure using the appropriate steam or water column. See current literature for determining the size of radiatorand convectors for hot water system'. GAS FIRED BOILERS American-Standard Gas boilers are design certified by the American Gas Association. Ratings shown are for installation at sea level and at elevations up to 2,000 feet. For altitudes above 2.000 feel, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. OIL FIRED BOILERS The firing rates or 1 = B = R burner capacities -- gallons per hour--are based on the use of oil having 140,000 Btu per gallon heat value. STOKER FIRED BOILERS The firing rates or I = B=rR burner capacities--pounds pei hour--are based on the use of coal having 13,000 Btu per pound heat value. HAND FIRED BOILERS The ratings are based on the use of stove or nut size bitumi nous coal, anthracite coal or coke with 13,000 Btu per pound heat value. See table below for selecting proper size boiler when using coal with less than 13.000 Btu per pound. BUILT-IN TANKLESS WATER HEATERS for G-2 Water, G-40, G-10, A-3, FR-A-5, and A-5 All tankless type built-in water heaters are rated m gallons per minute on the basis of a minimum boiler water temper ature of 200 F. The maintaining of 200 F boiler water temperature with rated flow through a tankless type builtin water heater is dependent on the output of the boiler. Increase the boiler size 12 Mbh for each m exce?.- of two. In those areas where excessive lime exi?'> m the watei use of built-in tankless type water heatei i? not recom mended except when provision is made foi legulaih clean ing the heater. EXTERNAL WATER HEATERS FOR AMERICAN-STANDARD STEAM BOILERS External tank or tankless type heaters can be connected to all American-Standard Steam boilers when provision is made in the supply and return piping of the heating system. When an external tank type heater is used and the domestic demand exceeds 75 gallons in a 24 hour period, increase the boiler size 120 Btuh for each gallon of storage tank capacity. When an external tankless type heater i- used, increase the boilei size 12 Mbh for each bathroom m exces" of two. (Note: G-10 Steam boilers can be provided with external water heater tappings for water to water heal exchangers. See G-10 optional equipment page^- foi price and availabil ity. A-7 boilers are regularly provided with tappings for external water to water heat exchange)' i WHERE COAL HAS LESS THAN 13,000 BTU CONTENT When selecting hand fired boilers for burning coal of lower heating value than 13,000 Btu per pound the following cor rection factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq. ft.). heating value of coal 13,000 12,500 12.000 11,500 11,000 correction factor 1.00 . 1.04 1.08 1.13 1.18 heating value of coal 10,500 10,000 9.500 9,000 correction factor 1.24 1.30 1.37 1.44 INSTRUCTIONS FOR ORDERING GAS BOILERS: Specify complete boiler number Specify type of gas (whether natural or propane). Btu (heat value of gas), specific gravity Specify elevation at point of installation if m excess of 2,000 feet and indicate barometric pressure In addition, for Pressure Fired PfA-5 gas fired ond gos-oil fired units, specify gas pressure at gas train inlet Specify optional equipment in detoil REPAIR PARTS --TRADE PRICES BOILERS Prices listed in Boiler Repair Parts Catalog Form 9100-2 Dated 3/1/71 Less 25% Oil Burners List Price Plus 21%, Less 25% For List Prices see "American Standard Arcoflame Oil Burner Repair Parts Catalog" 1966 Edition, HH-1 1 Page 51 02453 MEMO 02454 MEMO 02455 MEMO 02456 MEMO 02457 GENERAL TERMS ^AMERICAN LSstandard HYDRONIC HEATING TRADE PRICE BOOK illustrations and descriptions ol ordering Numbers listed in this price book will be found in the current American-Standard Hvdromc Products Catalog and literature. Items illustrated in product literature and not included m this price book are discontinued The illustrations in this price book although actual representations of certain products in the line, do not necessarily show sizes ano details of all products m the line ^Tnis price list has been prepared for the convenience of American-Standard distributors and their trade customers only. The trade prices shown are guides only and do not purport to represent actual prices prevailing in any particu'ar market and are net intended to interfere with our distributors' right and responsibility lo establish their own resale prices All prices herein set forth supersede alt prior price lists and are subject to change without notice Tne Seller may aisc. from time to time, discontinue without notice the sale of any of the products listed herein INVOICE MINIMUM All distributors' orders, including repairs, which aggregate less than $15.00 net will be billed at $15.00 TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH U.S. PLUMBING/HEATING TO ITS DISTRIBUTORS All sales of goods by American-Standard through U.S. Plumbing/Heating to its distributors are maoe subject to terms and conditions printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms These terms and conditions, are as follows PRICE Goods sold by the Seller will be billed to the Buyer according to the pnees and terms contained in its current bulletins and price books In the case of orders tor goods for which no price is currently in effect the price will be determined by the Seller and set forth m the invoice issued after shipment of the goods Taxes. Any tax or other Government charge now or hereafter levied upon me orodveuen sale use or shipment of goods ordered or sold, will be charged to and paid lor by the Buyer DELIVERY Transportation Risks. Delivery-to the initial earner shall constitute delivery to the Buyer The Setter's responsibility ceases upon delivery in good order to suen earner and all goods are shipped at the Buyer's risk The Buyer >s urged to examine all deliveries carefully before signing transportation receipts U goods are visibly damaged, the Buyer should insist that writien confirmation of the damage be noted on the freight bill or aray ticket by the agent of the earner If damage is discovered afier unpacking the carrier should be notified at once, so that inspection can be mace ano the claimed damage substantiated by the earner Interference with Delivery. The Seller has no obligation to deliver goods against any order until it has accepted the order by issuance of its acknowl edgment of order in any event, the Seller will not be liable for any delay or failure in (he delivery or shipment of goods against an accepted order or for any damages suflered by reason thereof, when such delay or failure is. directly or indirectly, due to accident (in manufacture or otherwise), fire, flood, riot, war embargo labor stoppages, inadequate transportation facili ties shortage of material or supplies, delay or default on the part of its vendors, regulation by Government authority, or any. like or dissimilar cause beyond its control CONSUMER PROTECTION - WARRANTY American-Standard products normally reach owners or consumer-users through an industry channel of distributors Bnd plumbing and heating con tractors. Experience has shown that claims of defects m our products gen erally reiaie to abuse or to other damage which occur after our sale and are no! our responsibility Since determining proper responsibility requires local inspection, our warranty (set forth below) extends only lo our direct buyers, distributors are best equipped to obtain the facts underlying claims, to place responsibility wnere it belongs and to recommend,'handle repair or re placement American-Standard warrants only to its distributors and other direct Buyers mai it will lurnish by freight a replacement for. or at its opiion repair any producl of its manulacture or part or portion thereof proved to its satisfac tion to be defective m material or workmanship under normal use ano service within one year after installation There is no other warranty, express or implied, including no implied war ranty of merchantability or implied warranty for fitness for a particular purpose and American-Standard wilt not be responsible lor any damages whatsoever, nor for labor or transportation expenses relating to such re placement or such repair Goods of other manufacturers sold by American-Standard are not warranted unless accompanied by an express written warranty, but the Seiler will endeavor to secure for its direct Buyers the benefits of warranties extended by such other manufacturers for such goods American-Standard is proud of ifs recorc 'o< product quality and for fair ness m handling warranty matters anc d an ultimate user of our products should feel our warranty system desenoed above does not work fairly in his case ne should write Ihe Office of me Pres'deni Director of ConsumeAflairs U S Plumbing/Healing Amencan-Stanaard 40 West 40lh Street New York, N Y 10018 CONTRACT WITH BUYEn Acceptance of Orders. Orders will be accepted omy ov me Seller s usua' acknowledgment of orcer containing termt arm cono'tions applicable thereto No terms and conditions appearing m a Buyer s orcer mar are a: variance with the Sellers terms anc conditions shall be pindina upon me Seller unless specifically agreed to by a m writing Unless the Seller spe cifically so agrees <n writing m acknowledging anv order any terms and conditions appearing in a Buyer s order contrary to those statec herein anc in such acknowledgment of order are to be deemed waived by the Buver Receipt by fhe Buyer of me acknowledgment of order without prompt ob.ee tion to the terms and conditions therein and herem set forth consMut? acceptance by the Buyer ol such terms and conditions Cancellation of Orders. After the Seller s acknowledgment of order has been issued, an order may be modihec o- cancelled only upon written agreement By the Seller Orders for gooes omer man ihose of sianoarc manufacture will not be cancelled alter a commitment has been made cproduction scheduled Credit for Returned Goods Merchandise nj, not be returned for credit unless the Seller has agreed to accept it Where returns are accepted a deduction of 10% or $10, whichever is greater will be made lor rehandling All transportation costs for returned goods must be paid by the Buyer In any evenl only saleable merchandise c( siandarc manulacture may be returned tor credit Credit Approval. Buyers' orders are accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stopped m transit on accepted orders without any liability on the Sellers pan if. m its opinion, the Buyer s ability to pay for me merchandise on these terms and conditions is m doubt SHORTAGES OR VARIANCES No claims for variances from or shortages m orders will be considered unless presented within 60 days after receipt of goods PRODUCT AND PACKAGING CHANGES Factors beyond the control of me Seller anc me need for continuing im provement of product reautre the maxing of changes from lime (o time in producls and their packaging The right is reserved to make reasonable changes of any kind without noiice anc io deliver revised designs or models ol goods against any order unless or. the face of the acknowfedgment ol order this right is specifically waived The Seller shall have no responsibility whatever with respecl to changes made by the manufacturer in products or meir packaging sold but not manufactured by the Seller SHIPPING WEIGHTS Tne shipping weights given nerem are approximate lor Buyers ccr vemence only, and are not guaranteed AMERICAN STANDARD Inc US PLUMBING'HE4 T tNG HH-1 1 Page 56 02458