Document J3k3KrXyM6B4zqbV55xde19m6
Inspection Report
Mechanical Integrity Test
Osage DNR / Environmental Protection Agency
1201 Elm Street, Suite 500
Dallas TX 75270
Inspector Matthew Allen
MIT Date 02/17/2026
Operator Representative McCann Resources, Inc
Report Sent Operator
Time 16:00
Inject Interval 787-797
USDW 87
Well Type Enhanced Recovery
Annulus Fluid Type Casing 4.5
Concentric Pkr Tubing
Packer Depth
Operator Info
McCann Resources, Inc 1613 West 6th Street Bartlesville, OK 740033404 Phone: 918-337-4747
Inventory ID API Well No Lease Name
Well ID
OS2221000
Parker W-88
Location SE 16 27N 12E
Type of MIT Ada Pressure Test
Test Reason Compliance Request
Injecting N
Injection Rate (bpd)
Tubular Lining
Ann Filled (hrs)
MIT Due
MIT Freq EVERY FIVE YEARS
Ann Press Mont
Time Pre-Test
Tubing Pressure 0
Annulus Pressure
Flowback Pressure High
Volume
Initial 16:00
340
Mid
Mid 16:15
340
Low
Final 16:30
340
End Total Volume
ADA Pressure Test - Required Test Pressure
(Fluid Column Ht * Specific Gravity * .433 / N2 Wt Fac =
Required Test Pressure)
Tubing
Annulus
Depth to Top Perf/Open Hole 787 Depth to Fluid Level 0
Fluid Column Level 787
Specific Gravity of Fluid 1.06
Nitrogen Weight Factor 1.0276
Required Pressure Test 351.500
Remedial Action Type
Fluid Migration Test Type
Inspection Comments
Inspector Signature
Remedial Action Type Well, OS2221000 achieved a test pressure of 340psi and maintained that pressure for the required 30minute observance period. The well was disconnected and not injecting. The well consisted of casing reduced to a 2" ball valve, there was no tubing or packer installed in the well. The well previously failed MIT and the operator discovered a casing leak approximately 4 feet below the surface. The casing leak was repaired.
MATTHEW ALLEN Date: 2026.03.02 11:43:26 -06'00' Digitally signed by MATTHEW ALLEN
Supervisor Signature JEANNE ECKHART Date: 2026.03.03 05:57:45 -06'00' Digitally signed by JEANNE ECKHART