pipelines, oveihead conveyors, other parts of the structure, and other installations is dis closed m studying the models A vertical dis tance of at least 7 ft generally is specified between passageways and stairways and over head structures to provide ample clearance Overhead cranes and conveyors require at least 24 in of vertical and horizontal clear ance Trucks and other vehicles require enough room for movement without endangenng men and equipment and need space to back and turn near machines Aisles should be wide enough to permit trucks to pass without colliding For one-way traffic, aisles should be not less than 3 ft wider than the widest vehicles Aisles for two-way traffic should be not less than 3 ft wider than twice the width of the widest vehicle These minimum widths are exceeded considerably in some new build ings where, because of anticipated heavy traf fic, aisles from 12 to 20 ft wide have been specified Safe layout of aisles requires that there be no blind comers and that adequate radius be provided to allow for vehicle turns A 6-ft radius is large enough for small industrial trucks Aisles should be clearly defined with ap proved markings of either traffic paint or striping material Follow American Nabonal Standard Z53 1, Safety Color Code for Mark ing Physical Hazards See the recommenda tions on pages 385-386 Plastic buttons that are glued or fastened with metal fasteners to the floor are used by many because of their durability Parking areas for both hand and power trucks should be designated Large plants often provide garages with room for both storage and maintenance See Chapter 27, "Powered Industrial Trucks," in this Manual If building plans include ramps for use by both pedestrians and trucks, a 3-ft wide sec tion should be reserved as a walkway Sharp turns into aisles at the top and bottom of ramps are hazardous and should be avoided Provide an abrasive coating where slippery floor conditions may exist Electrical equipment Complete metal-enclosed unit substations have been developed for industrial plants and are grounded Such rooms, however, are not proof against the hazards of oil-filled trans formers This equipment may give off flam mable gases under certain conditions, which may form an explosive mixture with the at mosphere in the room Nonflammable trans formers should be installed in confined areas and near flammable materials Short circuit protective devices should be large enough to carry the load and should be rated to open without any danger from the maximum short circuit current Circuit break ers, fuses, and safety switches that fail under short circuit current may explode and cause senous damage and injuries The potential of every grounding system should be measured with a meter to de termine whether or not the system is capable of conducting the necessary amount of return When direct current voltage is supplied from batteries, isolate the battery room from the work area Battery room should be well ventilated, no smoking should be permitted. In an up-to-date industrial electrical sys tem, sections may be de-energized for main tenance and other work without shutting down the entire system In addition, all electrical installations should conform to, the NFPA Na tional Electrical Code as well as local ordi nances Also see Chapter 41, "Electrical Hazards," in this Manual Major switching apparatus should have metal enclosures connected to the grounding system, and cable circuits likewise should be enclosed in rigid conduit or interlocked armor cable Metal-enclosed plug-in bus-ways should provide an easy method of connecting and disconnecting machine tools Ungrounded portable electric tools and equipment constitute a common source of fatalities in industry The hazard can be largely eliminated if plans include a threewire system, of which one is a ground wire, and if the equipment is provided with threeconductor cables (For additional information, see Chapter 41, "Electrical Hazards.") Ventilating, heating, and air conditioning Ventilating, heating, and air conditioning are needed both for personal comfort and very often to meet process conditions Personal comfort is very important because it affects 377