Document J3N2BX2QbkZgq2O6G7ejVjVXK

ASBESTOS - EVALUATION AND SURVEY Date /tl 2-T i9~?S Project_ -1 "y??0s v7&/C- Department /i/<& 7 7/-4///Z Bldg. VfC'ttJ3 Loca t i on No. $.U). C J/eRequested by .___Reason__ /*5S, General Conditions: J~ Ce// _ ** " -/is//*/* C................ _______________________ - Sampling Method and Equipment ?rc. -jl ? x </-/?/*- Sample Number / Sampling Time -Min. Flow Rate 79 JU/* CONCENTRATION Fibers/ml>5 p /.9? Sampled by 2iS, A'/S Special Conditions /97 ___________________ r. Calculation: (Avg, Fiber Count - Avg. Blank Count) Total Filter Area Concentration, fibers per (Counting Area) (Vot. Air-Liters) (1000) milliliters >5jj Remarks: Sketch - See reverse side. Reference Nofcft Analyzed by Date/f/ u /t?r UCC 024259 AOBTVSTCm COUNT RECORD SHEET . r.a^icili=^ /________ L5PERATIOIM T/?. -ytto*//*/----------------------------------------- FLOW ^ HMITIALO . TliV.E ^ VOLUWIE /77 / .-- .. --. ._ F.AREA 4XA-. PLK.CNT.AV. 0_________ AMVV*i COUNTi _lS COWrjEWi TnR*AMTiwlOmW* ii ! COMMENTS U<&J0* (w... ^ Ce //TT/y /3/S? 77 / rj-- ....... .........pi -------- . 7 7___ !1 r a 0 <5 'pi // 1 i / <? o, <? 73. ;/ 5- ! _ZJ__ 0i ../-i. <?J /. o &\ 0 0 /1 a 0 i. o '\ p 0 d o 2> ............. .1i A1* 0O < t /i / l\./} 0 / i / ~a________i 'id' __g?i # . Q . 05 f t /1 ; " '#) 0M 0\ o 7? L_^ (3i <? <? 1 O! ...o j /0o.... ~~0071\ . ~1 9 ........ J tfj <? <5> 0 i O 0 i l 2 ! / / ! / Q ... .s ...g` <gi <? / 9 ________I `o 0 0 Lo 0 / / <5> 0 o o f / <? f <? SO- 1 _/2!_Ol 7 0 0 /. / ? i - ^-- i V- 1. 1 1 ` i s I--------41--------;------S5~JNr- i ' * L_-- " 1t f Ss.::."-TOTALS 0- 2-f / X5 UCC 024260 INDUSTRIAL HYGIENE SAMPLING Date Jp-- /S' ~ pS________ CONTAMINANT s ftC^f ) Location - Bldg. Collected By /Room M IDENTIFICATION #/ ZfAT' */. ( - " rr,S) /")_______________ ,_____ ZS~ . f Z*"/Z/s'*/4 ) f ) ____M3 ZjT~ z*?/*/* //" c /zy+s } / /i/^c saris') ZJT yt-7 X A- f ZZ/pA/fsZ ) > Sampling Equipment Used *Z** / ^y9 S"?s.s/'s TM -^T^r V '-/P Operation being monitored Z ^ UCC 024261 %/*/? 77/ - Ce/S /0 0 j^/T/^?*S& /7 S*7f?s<*z *3T -- siT r/^ys&s* y<yfj*t/ # / \S0 jfj/ A/A*/s/rey' Ss/jr*/ # 77T, f*70 */ / jl/ 2-/S' /^e 2o jj's?S <? -yu e *Z L -^/ ~U>jl',/e /?** ^4*csm/*f *K;^5 T <y 7^// /V J TS S'/??*s s*ff &^ /lysv* */, <2- /s' --y>7 *s*S <7^ ^ /^sZ s^~?f/rjt '7</^Ve At s\*S &t?tf- &'//* 7s *y / ^ j sis #/,*S / 7^ //V7i <s> / 2V/ >v y Y^ ^ c/ J/ZsSs/ -- J^s9y/ -- y& - /y^/gTi2/- ~ sriwe<i VZ C " UCC 024262 jtf/Sf ?? / -Ce// /00 s- /r-'> 3 fc /^Co >r Acei /X / '^2, /, /=: oC<? --_ a? U~- { A__J) y /^Ocse )=: 3-15-73 jo Vts^ ft^iBSiS|(rn \ n-^ ^l&st^^7( .-fv4> (^.<c7z^ - J. o //tfc^TA/e^ - ^>-^--0? &-- /<? -- -- /s s ^ <j 'f- C <J ^s**J w * i^L />w Xe J) x ^a/c/ /^,/j-r r/o-fC. /) tf^~ - e^/ ///& -2. o-- /<?' y'/ -/ft/'J. // // // ^3 j 3 UCC 024263 7'b /s: 1.0 /'A - -1..0 it vT. ; ;> ^ VO-'. f.H O ^ / /*%. /J UCC 024264 AIR 5AMPLI NG^gjggrBT Building 'Z Z/ dJ/t/Qo Sampling Time Flow Rate, Ipm / /S . X Contorn i na n t Location and Remarks PgWM - f y rj __ ,. 2- /S " X /S''TruS*- X VX q.o4/ V/7 s*r /7|KKXa\ _ 11 ^l^njjn/ixi^vwc. < 1 C7 // YftftnXu f ----------- *?-- -------- --- '/ //?/-> ?/' XZ S d /o ZiXe Xc i'\. /f " 'iT jvr- '- r/^/S UCC 024265 Signed /^.jsjzjllf. // a J:$r /o Tyu^- EcH j^ S' * ; l^-1- -! p '"'-C *f f, ^r C i * w t*' U j f Aa^ Or; UCC 024266 INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER P.O- BOX B361. SOUTH CHARLESTON. WV 25303 Toirjam1L F. Terry Division yQ^j LDC""n 511 Area CoPV" C. P. Maxwell - 701/2 R. G. Rowe, M.D. - 791 C. L. Ruddle - 704 R. E. Sergent - 704 Dace April 3, 1987 EM&TSOriginating Dept - HS&EA Area Industrial Hygiene Subject Asbestos Exposure Monitoring Attached are the results of the Asbestos exposure monitoring performed on J. W. Greenlee on March 20, 1987. He was monitored while stripping approximately 10 feet of Asbestos from a line in the Building 740 basement. He also stripped Asbestos tape from miscellaneous lines in salvage piles near Buildings 771 and 773. He was equipped with an A0R57A Half-face HEPA cartridge respirator, 2 pair of coveralls with headcover, boots and gloves. Mr. Greenlee showered before going home. The exposure monitoring results indicate that the levels were well below the 0.1 fiber/cc Action Level, established by OSHA for an 8-hour workday (TWAg). The low level indicates that the established procedures are adequate and that they were followed closely. Please notify J. W. Greenlee of his exposure monitoring results as soon as possible. Please have him sign and date this report and return to M. A. Patel at Building 701-330. If we can be of further assistance, please call us on extension 4779 or 3750. APPROVED BY: Attachment VES:MAP:rab 2216P Manhar A. Patel UCC 024267 Carp. Ref. W2163 . ASBESTOS EXPOSURE MDNIT0RIM3 Date 3-20-87 Sanple T>pe/ Etrplqyee Nate Sanpling Time Personal/ 7hrs l&rrin J. W. Greenlee Air Cone Fibers/cc TWg Fibers/cc COMCKTS 0.036 0.0327 Collected while stripping 10 feet of asbestos from a line using Glove Bags. He also stripped asbestos tape from lines in salvage piles, near Buildings 771 and 773. ASBESTOS Permissible Exposure Level TWfc Action Level 0.2 Fiber/oc 0.1 Fiber/cc OSHA 2216P rab UCC 024268 INDUSTRIAL HYGIENE MONITORING FOR - TO: R. F. Painter, Trlr. 5583 ASBESTOS FILE COPY Computer Ref. W1167 04/22/81 CC: C. W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009 PERSON MONITORED R. E. E. J. Tawney, Trlr.5583 H. L. E. C. Shipley, 511-2009 J.. F Location EXPOSURE RESULTS West end - Bldg. 773 Outside at tank pad Date 04/20/81 Sample 1 2 3 Cone. fibers !> 5 <.1 gm/cm3 fibers > 5 <1 pm/cm3 Sampling Time 78 minutes 125 minutes Comments A.M. - Stripping P.M. - Stripping, bagging and cleanup 4 5 6 Time-Weighted Average Concentration (TWA) Ceiling Concentration o <.l Fiber > 5 pm/cnr3 ALLOWABLE EXPOSURE TWA 2 Fibers >5 pm/ Ceiling cm 0SHA ucc <^OsSl) other UCC Other ' COMMENTS Insulator monitored while stripping approximately 100 feet of 1-1/2" pipe of suspected asbestos containing insulation. He wore coveralls and a disposable Norton dust respirator. The insulation was properly bagged and tagged for disposal at the landfill. WORK BY APPROVED BY UCC 024269 VStJ CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS F IiLlEl CuOuPr Yv TO: H. F. Painter, Trlr. 5583 Computer Ref. W1167 04/22/81 CC: C. W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009 R. E. Peele, 701-334 E. J. Tawney, Trlr. 558: H. L. Robinson, 701-401 E. C. Shipley, 511-2009 PERSON MONITORED ______________D. C. Shamblin Location West end - Bldg. 773 Date Outside at tank pad EXPOSURE RESULTS 04/20/81 Sample 1 2 3 4 5 6 Cone. fibers > 3 . 1 um/cm^ fibers > 5 . 2 fim/cm3 Sampling Time 85 minutes 123 minutes Comments A.M. - Stripping P.M. - Stripping, bagging and cleanup Time-Weighted Average Concentration (TWA) .1 Fiber > 5 pm/cm3 Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 Fibers > 5 pm/ (OSHA) Ceiling cm3 OSHA UCC UCC Other Other COMMENTS Insulator monitored while stripping approximately 100 feet of 1-1/2" pipe of suspected asbestos containing insulation. He wore coveralls and a disposable Norton dust respirator. The insulation was properly bagged and tagged for disposal at the landfill. WORK BY APPROVED BY X UCC 024270 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS FjjLE COPY | TO: W. T. Shelton, 704 Computer Ref. 1033 CC: G. F. Hurley H. L. Robinson PERSON MONITORED Location EXPOSURE RESULTS J. W. Greenlee Bldg. 773 - First floorDate ________4/1/80 along north wall near operating area. Sample 1 2 3 4 5 6 Cone. 0.4 0.2 Sampling Time 85 min. 115 " Comments At-M. P.M. - Stripping & bagging tion -" " Time-Weighted Average Concentration (TWA) Ceiling Concentration 0.1 fibers > 5 gm/cin^ ALLOWABLE EXPOSURE TWA 2 fibers > 5 pm/cm3(0SHA^ Ceiling ________________________ OSHA UCC UCC Other Other COMMENTS Approximately 48 feet of 3-inch condensate line was stripped of suspected asbestos containing insulation. The insulation was kept wet during the stripping. The insulator wore coveralls and a dis posable 3M dust respirator. Stripped asbestos was placed in plastic bags for disposal. UCC 024271 AUDIT REPORT NO. PILE NO. 7 ATTENTION This document has been identified as one which may relate to the manufacture, use, sale or health effects of asbestos or asbestos-containing products in connection with Union Carbide's defense of asbestos litigation. The document may be reproduced as needed, but should not be destroyed. If it is judged to be of no further value to this file, the document should be sent to the Danbury office, attention of S. D. Conner. The File No. and Audit Report No. must accompany the document Likewise, if the address of the document is changed, S. D. Conner should be notified. The File No. and Audit Report No. must be included in the correspondence. UCC 024272 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: W. T. Shelton, 704 Computer Ref. 1033 CC: g. F. Hurley H. L. Robinson PERSON MONITORED Location EXPOSURE RESULTS ______________R. E. Raines Bldg. 773 - Along north Date wall near operating area. 4/1/80 Sample 1 2 3 4 5 6 Cone. 0.2 fibers 0.1 fibers Sampling Time 86 min. 110 min. Comments A. 1ft'- - Stripping & bagging P.M. - " " Time-Weighted Average Concentration (TWA) Ceiling Concentration 0.1 fibers > 5 pm/cm3 ALLOWABLE EXPOSURE TWA 2 fibers > 5 pm/cm3 (qshJ) Ceiling _ OSHA UCC UCC Other Other COMMENTS Stripped 48 feet of 3-inch condensate line of suspected asbestos containing insulation which was well wetted. Mr. Raines wore a 3M disposable dust repirator during the stripping and bagging. The stripped insulation was placed in plastic bags for disposal. UCC 024273 INTERNAL CORRESPONDENCE __ FllE COPY 1 4EMICALS AND PLASTICS (Name) ;atior*i py Mr. W. T. Shelton Building 704 Shop Mr. G. F. Hurley Mr. G. C. Merz Mr. M. E. Perry Mr. H. L. Robinson P O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 D*te November 5, 1979 original-,ng DePiTechnica 1 Center IH/EP Subiect Asbestos - Stripping Old Insulation PROJECT Survey for asbestos exposure of insulators stripping insulation from a 12-inch by 10-foot reactor column located on the north-west side of Building 773. DATE OF SURVEY November 2, 1979 SUMMARY AND CONCLUSIONS Good judgement and proper housekeeping techniques by insulators kept the exposure to asbestos fibers at a minimum. The reactor insu lation was wet down with a water spray can and dismantled with a mini mum amount of handling. Coatings mechanics, Mr. Monin and Mr. Greenlee, wore 3M disposable dust masks, gloves, and coveralls. The stripped material was bagged and labeled for landfill. The exposures were below the TWA of 2 fibers/cc and a ceiling value of 10 fibers/cc. RESULTS Location Building 773 Building 773 Personnel J.R. Monin J.W. Greenlee Sampling Time-Min. 46 . 43 Exposure Fibers/cc >5 pm . 0.4 0.1 UCC 024274 Mr. W. T.. Shelton 2 11/5/79 REFERENCES Volume 38C-29X4-Rla Asbestos, Dust Determination By Membrane Filter Techniques Using Phase Contrast Microscopy REPORT PREPARED BY G. W. Bott Technical Center Industrial Hygiene Group APPROVED BY GWB/sc UCC 024275 ' t'fl i:) .'S . ijUMHl ijz imtcdkjai . rnorPCDnKinPMrc _____ `' r _____ HI F CHEMICALS AND PLASTICS * P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 l i\ ivtn C C 11 r. n 'cpy tc Mr. Mr. Mr. Mr. D. H. R. F. H. L. T. W. Cook Painter Robinson Souder Dale Oricjinarmg Subject January 9, 1979 Technical Center IH/EP Monitoring Insulators PROJECT Monitoring insulators for asbestos exposure. DATE OF SURVEY December 12 and 13, 1978 DISCUSSION Messrs. Brad Nester and Charlie Miller, Construction . insulators, were monitored for asbestos exposure on December 12 and 13, while removing insulation from piping on the third level of Building 773, Both men wore respirators during the operations. On the first day only a small amount of water was applied to the insulation before removal to minimize the emission of airborne asbestos fibers. Personnel exposures were 2.8 and 1.3 fibers per cubic centimeters of air (f/cc) respectively. On the second day of monitoring, December 13, the insulation was thoroughly wetted with water before, during, and after removal. As a result, the air concentrations in the breathing zones of the insulators were reduced to 0.3 and 0.4 f/cc. The OSHA standard for an eight- hour exposure is 2.0 f/cc. RECOMMENDATIONS As evidenced by this monitoring, it is essential that extra time be taken to thoroughly wet asbestos- containing insulation before, during, and after removal. For small stripping operations a portable garden water sprayer can be used. REFERENCES UCC C/P Industrial Hygiene Method 38C-29X4-Rla 29CFR 1910.1001 UCC 024276 DATA Location: Building 773, third level Date 12/12/78 12/12/78 12/13/78 12/13/78 Employee Brad Nester Charlie Miller Brad Nester Charlie Miller Sampling Time 0950-1038 0950-1038 1335-1350 1335-1350 Air Cone. Fibers/cc 2.8 1.3 0.4 0.3 REPORT PREPARED BY W. F. Blythe, Jr. Technical Center Industrial Hygiene Group WFBJr/sc W. F."Blythe, Jr. '' UCC 024277 INTERINJAL CORRESPONDENCE 5H FILE UNION CARBIDE CORPORATION TECHNICAL CENTER P.C. BOX 8361, SOUTH CHARLESTON, WV S53Q3 ToiN0mEC. W. Wible ' 770/162 Loc.otiOr"' 511 Area P.Copy CO D. Gossage - 701/4 C. P. Maxwell - 701/2 R. G. Rowe, M.D. - 791 -- R. E. Sergent - 704 July 15, 1987 "g EM&TS - HS&EA Area Industrial Hygiene Asbestos Exposure Monitoring Attached are the results of the non-abatement asbestos exposure monitoring performed on J. A. Ingram and W. S. Ball ingall while pulling computer cable above ceiling tile and through service shafts in Building 770. They were equipped with Half-face Willson R-12 HEPA filtered respirators. The exposure monitoring indicates that the levels were well below the 0.1 fiber/cc Action Level, established by OSHA for an 8-hour workday (TWAg). However, anyone working above or removing ceiling tile must continue to wear the protective equipment, mentioned above, until enough data is gathered to indicate a problem does not exist, whenever doing this type of work. Please notify J. A. Ingram and W. S. Ball ingall of their exposure monitoring results as soon as possible. Please have them sign and date this report and return to M. A. Patel at Building 701-330. If we can be of further assistance, please feel free to call us on extension 4779 or 3750. WORK BY: APPROVED BY: Attachment VES:MAP:rab 2488P Manhar A. Patel UCC 024278 ASBESTOS EXPOSURE MONITORING Carp. Ref. W2236 Sanple Type/ Date Enployee Name 7-2-87 Personal/ J. A. Ingram Sarrpling Tire Air Cone. Fibers/cc TOAg Fibers/cc COWENTS 7hrs 3 min 0.0375 0.033 Collected while pulling carputer cable above ceiling tile and inside of service shafts in Building 770. Job took approx. 4 hours to carpi ete. 7-2-87 Personal/ W. S. Ball ingall 6hr$ 56min 0.0148 0.0128 Collected while pulling carputer cable above ceiling tile and inside of service shafts in Building 770. Job took approx. 4 hours to carpi ete. ASBESTOS Permissible Exposure Level TWg 0.2 fibers/cc OSHA Action Level 0.1 fibers/cc 2488P UCC 024279 UNION CARBIDE CORPORATION TECHNICAL CENTER P.O BOX 83B1, SOUTH CHARLESTON, WV 25303 To INenne) Division Location Area L. A. Kapicak 770-240 511 C. P. Maxwell - 701/256 R. E. Sergent- 704/2 P. D. Sherman - 701/254 P. H. Wadi a -770/304 ate October 29, 1986 Originating Dept EM&TS - HS&EA Area Industrial Hygiene sublet Asbestos Area Monitoring Attached are the monitoring results of the Asbestos Area samples collected in 770-137 on October 23, 1986. The samples were collected to determine the level of airborne fibers present in this lab. Insulators had cleaned, from the floor area. Asbestos containing materials the evening of October 22, 1986. The samples when counted did not show fiber count any greater then the blank samples and therefore, the results are well below the 0.1 fiber/cc action level, established by 0SHA for an 8-hour workday. If we can be of further assistance, please call us on extension 4779 or 3750. WORK BY: APPROVED BY: Vance E. Stover Attachment VES:MAP:rab 1837P X. (Ui Manhar A. Patel UCC 024280 ASBESTOS AREA MONITORING \ Comp. Ref. W2069 Date Sampling Time Air Cone, fibers/cc COMMENTS.......................... 10-23-86 7 hrs 28 min. < 0.003 Collected at the face of the hood behind J. Winkler's desk and very near the point where the Asbestos was lying on the floor. 10-23-86 7 hrs 29 min. ^ 0.003 Collected on top of J. Winkler's desk. 10-23-86 7 hrs 24 min. <0.003 Collected near the double doors that enter the hallway. ASBESTOS Permissible Exposure Level m---------------------- ----------------: 0.2 fiber/cc Action Level 0.1 fiber/cc OSHA 1837P UCC 024281 INTERNAL CORRESPONDENCE i UNION CARBIDE CORPORATION technca. cent eh? R.O BCJX 036 1 . !iOU r'-> CHARLESTON. WV Ez'ISBC BUSINESS CONFIDENTIAL A. F. Terry 704 Shop 511 C. P. Maxwell R. G. Rowe, M.D. C. L. Ruddle R. E. Sergent July 24, 1986 HS&EA Industrial Hygiene Asbestos Exposure Monitoring Attached are the results of the Asbestos monitoring done in Building 770 on June 23, 1986. R. E. Raines and R. P. Hess were monitored while they removed approximately 15 feet of Asbestos from a steam line inside of the S-5 air handler during off-hours. They were equipped with disposable coveralls, boots, disposable dust mask, gloves and head cover. The air handler was shut down and the area was barricaded. Plastic was put on the floor, under the steam line, and excess water was used for wetting down the insulation. The Asbestos insulation, as well as the plastic was removed very diligently. The floor was flooded with water and vacuumed. The sample results show that for the very short sampling time, the potential exposure to Asbestos was low. If it was averaged over an 8-hour period, it would be well below the permissible exposure level of 2 fiber/cc of air. An 8-hour average was not established because both R. E. Raines and R. P. Hess indicated that they worked with insulation, that may have contained Asbestos, earlier in the day before this job was done. Please inform R. E. Raines and R. P. Hess of their exposure results and if we can be of further assistance, please call us on extension 4779 or 3750, WORK BY: APPROVED BY: Vance E. Stover VES/jac 1512P Manhar A. Patel UCC 024282 K * Comp Ref W/1999 Date 6-23-86 6-23-86 6-23-86 Sample Type Employee Name Personal/ R.E. Raines Personal/ R. P. Hess Area ASBESTOS EXPOSURE MONITORING Sampling Time Air Cone Fibers/cc TWAg Fibers/cc Comments 59 min 0.928 ------------ Collected while removing and bag ging 15 feet of Asbestos from 770-S-5 Air Handler 58 min 1.35 -------------- Collected while removing and bagging 15 feet of Asbestos from 770-S-5 Air Handler 1 hr 3 min 0.420 ------------- Collected inside of Air Handler about waist high setting on precipitron. Asbestos Permissible Exposure Levels* TWAg 2 fibers/cc OSHA Ceiling 10 fibers/cc * OSHA Guidelines in effect at time of monitoring. 1512P UCC 024283 INDUSTRIAL HYGIENE MONITORING FOR: ASBESTOS v. * ` 0 BUSINESS CONFIDENTIAL Computer Ref: W-1500 Bate: Nov. 18/ 1983 To: W. T. Shelton, 704 SHop c c: R. E. F'eele/ 701--334 R. G. Roue, M.D.> 791 PERSON MONITORED: J. W. Greenlee LOCATION: 770 Fan Room EXPOSURE RESULTS Sample No. Cone. Sampling Time Date: 11/8/83 Comments 1 0..2 9 fibers/cc 134 Minutes Personal sample 0. 06 fibers/cc 23 Minutes Area sample 3 0.03 fibers/cc 97 Minutes Area sample 4 0.05 fibers/cc 97 Minutes Area sample Time-Weighted Average Concentration <TWA): Ceiling Concentration: ALLOWABLE EXPOSURE TWA: .5 fibers/cc Ceiling: - _X OSHA ______OSHA ______UCC ______UCC ______Other ______Other COMMENTS Personal and area samples were collected while Mr. Greenlee stripped insulation from a steam line in Building 770 Fan Room. The line was located on S-5 precipitron. Mr. Greenlee stripped six feet of insulation from a two-inch steam line outside the precipitron and twenty feet of insulation from the line inside the precipitron. Mr. Greenlee wore a respirator/ gloves/ paper suit and hood while per forming his work and during the cleanup operation. The area was barri caded and a sign posted. Please inform IH Department of the next stripping job in this area and inform Mr. Greenlee of his exposure. Please note the change in OSHA standard from 2 fibers/cc to . 5 fihers/cc. WORK APPROVED BY: UCC 024284 X 'SIj-J Manhi.ii' A. Patel J CARHIO CONFIDENTIAL L " INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS FILE COPY TO: W. T. Shelton, 704 Shop Computer Ref. W-1207 Date July 30, 1981 cc: R. E. Peele, 701-334 H. L. Robinson, 701-401 PERSON MONITORED Location J. W. Greenlee Bldg. 770-137 Date 07/24/81 EXPOSURE RESULTS Sample No. Cone . fibers >5 pm/cm3 Sampling Time 52 Minutes 2 Comments Insulator stripping approx. 60 feet of insulation from a 1/2-inch steamline. 3 4 5 6 Time-Weighted Average Concentration (TWA) Ceiling Concentration < ,1 fibers > 5 pm/cnP ALLOWABLE EXPOSURE TWA 2 fibers > 5 pm/cm3 Ceiling __________________________ . X OSHA OSHA UCC UCC _____Other Other COMMENTS The 52 minutes sampling time represents the total job. APPROVED BY UCC 024285 Manhar A. Patel CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR TO: W, T. Shelton, 704 Shop ASBESTOS Computer R6f. W-1207 Date July 30, 1981 cc: R. E. Peele, 701-334 H. L. Robinson, 701-401 PERSON MONITORED Location Bldg. 770-137 J. R. Monin Date 07/24/81 EXPOSURE RESULTS Sample No. Cone. fibers r 1 .7 >5 pm/cm* 1 2 Sampling Time 51 Minutes Comments Insulator bagging stripped insulat ion. 3 4 5 6 Time-Weighted Average Concentration (TWA) < .1 fibers > 5 gm/cm Ceiling Concentration ALLOWABLE EXPOSURE TWA 3 2 fibers > 5 aro/cm Ceiling __________________________ X OSHA OSHA _____UCC UCC Other Other COMMENTS The 51 minutes sampling job represents the complete job. WORK BY Ruth Clise APPROVED BY UCC 024286 Manhar A. Patel INTERNAL CORRESPONDENCE 1 FILE.CDPrt HEMICALS AND PLASTICS * P. C. BOX 6361, SOUTH CHARLESTON, WEST VIRGINIA 25303 (Nam;) vision caiiori 'PY Mr. W. T. Shelton Building 704-Shop Ms. M. M. Gilbert Mr. M. E. Perry Mr. H. L. Robinson Dr. F. G. Young Dare March 26, 1980 c 3,r,nt ,g c.p, Technical Center IH/EP ; bfd Asbestos Monitoring in Building 770 PROJECT Monitor exposure of insulators to asbestos during the removal of insulation tape from tubing in Room 237 of Building 770. DATE OF SURVEY March 19, 1980 DISCUSSION Services insulators R. E. Raines and J. W. Greenlee wore per sonal samplers while removing asbestos tape from various lines in Room 237 of Building 770. An area sample was also taken on a desk in the northwest corner of the room. Due to asbestos tape's disin clination to emit airborne asbestos fibers, the tape was not wetted with water during removal. However, respirators were worn and the area was barricaded in accordance with OSHA regulations. All samples indicated concentrations of less than 0.1 fibers/cubic centimer of air (f/cc). The current OSHA standard sets a ceiling limit for a 15~minute exposure of 10 f/cc and a limit of 2 f/cc for an eight-hour timeweighted average exposure. Further monitoring of asbestos tape removal will not be required. REPORT PREPARED BY W. F. Blythe, Jr. APPROVED BY G. F. Hurley WFBJr/sc UCC 024287