Document J3N2BX2QbkZgq2O6G7ejVjVXK
ASBESTOS - EVALUATION AND SURVEY
Date /tl 2-T i9~?S Project_ -1
"y??0s v7&/C-
Department
/i/<& 7 7/-4///Z Bldg.
VfC'ttJ3 Loca t i on
No.
$.U). C J/eRequested by
.___Reason__ /*5S,
General Conditions: J~ Ce//
_
**
" -/is//*/*
C................
_______________________ -
Sampling Method and Equipment
?rc. -jl ? x </-/?/*-
Sample Number
/
Sampling Time -Min.
Flow Rate
79
JU/*
CONCENTRATION Fibers/ml>5 p
/.9?
Sampled by
2iS, A'/S
Special Conditions
/97
___________________
r.
Calculation: (Avg, Fiber Count - Avg. Blank Count) Total Filter Area Concentration, fibers per
(Counting Area) (Vot. Air-Liters) (1000)
milliliters >5jj
Remarks: Sketch - See reverse side. Reference Nofcft Analyzed by
Date/f/ u /t?r
UCC 024259
AOBTVSTCm COUNT RECORD SHEET
.
r.a^icili=^
/________ L5PERATIOIM T/?. -ytto*//*/-----------------------------------------
FLOW ^ HMITIALO .
TliV.E ^ VOLUWIE /77 / .--
.. --. ._ F.AREA 4XA-. PLK.CNT.AV.
0_________
AMVV*i COUNTi _lS
COWrjEWi TnR*AMTiwlOmW* ii !
COMMENTS U<&J0*
(w...
^
Ce //TT/y /3/S? 77 /
rj--
.......
.........pi
--------
.
7 7___ !1 r a
0 <5 'pi
//
1 i
/ <?
o, <?
73. ;/
5- !
_ZJ__ 0i
../-i. <?J /.
o &\ 0 0 /1 a 0 i. o '\ p
0 d o
2>
............. .1i
A1*
0O <
t /i /
l\./} 0 / i / ~a________i
'id'
__g?i # . Q .
05 f
t /1
; " '#)
0M
0\ o
7? L_^ (3i <?
<? 1
O! ...o j
/0o.... ~~0071\ .
~1
9
........ J
tfj <? <5> 0 i O 0
i
l 2 ! / / ! / Q
... .s
...g` <gi <? /
9 ________I
`o 0
0 Lo 0
/ / <5> 0 o o
f
/ <? f <? SO- 1 _/2!_Ol 7 0 0
/. /
? i -
^--
i V-
1.
1 1 `
i
s
I--------41--------;------S5~JNr-
i '
*
L_-- "
1t
f
Ss.::."-TOTALS
0- 2-f
/ X5
UCC 024260
INDUSTRIAL HYGIENE SAMPLING
Date Jp-- /S' ~ pS________
CONTAMINANT
s ftC^f )
Location - Bldg. Collected By
/Room M
IDENTIFICATION #/
ZfAT' */.
( - " rr,S) /")_______________ ,_____
ZS~ . f Z*"/Z/s'*/4 ) f
)
____M3
ZjT~ z*?/*/* //" c /zy+s } / /i/^c saris')
ZJT yt-7 X A-
f ZZ/pA/fsZ )
>
Sampling Equipment Used
*Z** / ^y9 S"?s.s/'s TM -^T^r V '-/P
Operation being monitored Z
^
UCC 024261
%/*/?
77/ - Ce/S /0 0
j^/T/^?*S& /7
S*7f?s<*z *3T --
siT r/^ys&s*
y<yfj*t/ # /
\S0 jfj/ A/A*/s/rey'
Ss/jr*/ # 77T, f*70 */ / jl/
2-/S'
/^e 2o jj's?S
<? -yu e *Z L
-^/
~U>jl',/e /?** ^4*csm/*f *K;^5
T <y 7^// /V J TS S'/??*s s*ff
&^
/lysv* */,
<2- /s' --y>7 *s*S <7^ ^
/^sZ s^~?f/rjt '7</^Ve
At s\*S &t?tf-
&'//* 7s *y / ^ j sis #/,*S /
7^ //V7i <s> / 2V/ >v
y Y^ ^ c/ J/ZsSs/ -- J^s9y/ -- y&
- /y^/gTi2/- ~
sriwe<i
VZ C "
UCC 024262
jtf/Sf
?? / -Ce// /00
s- /r-'> 3
fc
/^Co >r Acei
/X / '^2, /, /=:
oC<? --_
a? U~-
{ A__J)
y
/^Ocse )=:
3-15-73
jo Vts^ ft^iBSiS|(rn \ n-^
^l&st^^7(
.-fv4> (^.<c7z^ - J. o
//tfc^TA/e^ - ^>-^--0? &-- /<? -- -- /s s ^
<j 'f- C <J ^s**J w * i^L />w Xe J)
x
^a/c/ /^,/j-r r/o-fC.
/) tf^~ - e^/ ///& -2.
o-- /<?'
y'/
-/ft/'J.
// // // ^3
j
3
UCC 024263
7'b
/s:
1.0
/'A - -1..0 it vT. ; ;> ^ VO-'.
f.H O ^
/
/*%.
/J
UCC 024264
AIR 5AMPLI NG^gjggrBT
Building 'Z Z/ dJ/t/Qo
Sampling Time
Flow Rate, Ipm
/ /S . X
Contorn i na n t
Location and Remarks
PgWM -
f y rj __ ,.
2- /S " X
/S''TruS*-
X
VX
q.o4/
V/7
s*r
/7|KKXa\ _
11
^l^njjn/ixi^vwc.
< 1 C7
//
YftftnXu f
-----------
*?-- -------- ---
'/ //?/-> ?/' XZ S
d /o ZiXe Xc i'\.
/f " 'iT jvr- '- r/^/S
UCC 024265
Signed /^.jsjzjllf. //
a
J:$r
/o Tyu^-
EcH j^
S' * ; l^-1- -!
p
'"'-C *f f,
^r C i * w
t*' U
j f Aa^ Or;
UCC 024266
INTERNAL CORRESPONDENCE
UNION CARBIDE CORPORATION TECHNICAL CENTER
P.O- BOX B361. SOUTH CHARLESTON. WV 25303
Toirjam1L F. Terry
Division yQ^j
LDC""n 511
Area
CoPV" C. P. Maxwell - 701/2 R. G. Rowe, M.D. - 791 C. L. Ruddle - 704 R. E. Sergent - 704
Dace
April 3, 1987
EM&TSOriginating Dept - HS&EA
Area Industrial Hygiene
Subject
Asbestos Exposure Monitoring
Attached are the results of the Asbestos exposure monitoring performed on J. W. Greenlee on March 20, 1987. He was monitored while stripping approximately 10 feet of Asbestos from a line in the Building 740 basement. He also stripped Asbestos tape from miscellaneous lines in salvage piles near Buildings 771 and 773.
He was equipped with an A0R57A Half-face HEPA cartridge respirator, 2 pair of coveralls with headcover, boots and gloves. Mr. Greenlee showered before going home.
The exposure monitoring results indicate that the levels were well below the 0.1 fiber/cc Action Level, established by OSHA for an 8-hour workday (TWAg). The low level indicates that the established procedures are adequate and that they were followed closely.
Please notify J. W. Greenlee of his exposure monitoring results as soon as possible. Please have him sign and date this report and return to M. A. Patel at Building 701-330.
If we can be of further assistance, please call us on extension 4779 or 3750.
APPROVED BY:
Attachment
VES:MAP:rab 2216P
Manhar A. Patel
UCC 024267
Carp. Ref. W2163 .
ASBESTOS EXPOSURE MDNIT0RIM3
Date 3-20-87
Sanple T>pe/ Etrplqyee Nate
Sanpling Time
Personal/
7hrs l&rrin
J. W. Greenlee
Air Cone Fibers/cc
TWg Fibers/cc
COMCKTS
0.036
0.0327
Collected while stripping 10 feet of asbestos from a line using Glove Bags. He also stripped asbestos tape from lines in salvage piles, near Buildings 771 and 773.
ASBESTOS Permissible Exposure Level
TWfc Action Level
0.2 Fiber/oc 0.1 Fiber/cc
OSHA
2216P rab
UCC 024268
INDUSTRIAL HYGIENE MONITORING FOR -
TO: R. F. Painter, Trlr. 5583
ASBESTOS FILE COPY
Computer Ref. W1167 04/22/81
CC:
C. W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009
PERSON MONITORED
R. E.
E. J. Tawney, Trlr.5583
H. L.
E. C. Shipley, 511-2009
J.. F
Location EXPOSURE RESULTS
West end - Bldg. 773 Outside at tank pad
Date
04/20/81
Sample 1 2 3
Cone. fibers !> 5
<.1 gm/cm3
fibers > 5 <1 pm/cm3
Sampling Time
78 minutes
125 minutes
Comments A.M. - Stripping
P.M. - Stripping, bagging and cleanup
4
5
6
Time-Weighted Average Concentration (TWA) Ceiling Concentration
o <.l Fiber > 5 pm/cnr3
ALLOWABLE EXPOSURE
TWA
2 Fibers >5 pm/
Ceiling cm
0SHA
ucc
<^OsSl) other
UCC
Other
'
COMMENTS
Insulator monitored while stripping approximately 100 feet of 1-1/2" pipe of suspected asbestos containing insulation. He wore coveralls and a disposable Norton dust respirator. The insulation was properly bagged and tagged for disposal at the landfill.
WORK BY APPROVED BY
UCC 024269
VStJ CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR
ASBESTOS
F IiLlEl CuOuPr Yv
TO: H. F. Painter, Trlr. 5583
Computer Ref. W1167 04/22/81
CC: C. W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009
R. E. Peele, 701-334 E. J. Tawney, Trlr. 558: H. L. Robinson, 701-401 E. C. Shipley, 511-2009
PERSON MONITORED
______________D. C. Shamblin
Location West end - Bldg. 773 Date Outside at tank pad
EXPOSURE RESULTS
04/20/81
Sample 1 2 3 4 5 6
Cone.
fibers > 3 . 1 um/cm^
fibers > 5 . 2 fim/cm3
Sampling Time
85 minutes
123 minutes
Comments
A.M. - Stripping
P.M. - Stripping, bagging and cleanup
Time-Weighted Average Concentration (TWA) .1 Fiber > 5 pm/cm3 Ceiling Concentration
ALLOWABLE EXPOSURE
TWA
2 Fibers > 5 pm/ (OSHA) Ceiling cm3 OSHA
UCC UCC
Other Other
COMMENTS
Insulator monitored while stripping approximately 100 feet of 1-1/2" pipe of suspected asbestos containing insulation. He wore coveralls and a disposable Norton dust respirator. The insulation was properly bagged and tagged for disposal at the landfill.
WORK BY APPROVED BY
X
UCC 024270
INDUSTRIAL HYGIENE MONITORING FOR
ASBESTOS
FjjLE COPY |
TO:
W. T. Shelton, 704
Computer Ref.
1033
CC:
G. F. Hurley H. L. Robinson
PERSON MONITORED Location
EXPOSURE RESULTS
J. W. Greenlee
Bldg. 773 - First floorDate ________4/1/80 along north wall near operating area.
Sample 1 2 3 4 5 6
Cone. 0.4 0.2
Sampling Time
85 min.
115 "
Comments
At-M. P.M.
- Stripping & bagging tion
-"
"
Time-Weighted Average Concentration (TWA) Ceiling Concentration
0.1 fibers > 5 gm/cin^
ALLOWABLE EXPOSURE
TWA
2 fibers > 5 pm/cm3(0SHA^
Ceiling ________________________
OSHA
UCC UCC
Other Other
COMMENTS
Approximately 48 feet of 3-inch condensate line was stripped of suspected asbestos containing insulation. The insulation was kept wet during the stripping. The insulator wore coveralls and a dis posable 3M dust respirator. Stripped asbestos was placed in plastic bags for disposal.
UCC 024271
AUDIT REPORT NO.
PILE NO.
7
ATTENTION
This document has been identified as one which may relate to the manufacture, use, sale or health effects of asbestos or asbestos-containing products in connection with Union Carbide's defense of asbestos litigation. The document may be reproduced as needed, but should not be destroyed. If it is judged to be of no further value to this file, the document should be sent to the Danbury office, attention of S. D. Conner. The File No. and Audit Report No. must accompany the document
Likewise, if the address of the document is changed, S. D. Conner should be notified. The File No. and Audit Report No. must be included in the correspondence.
UCC 024272
INDUSTRIAL HYGIENE MONITORING FOR
ASBESTOS
TO:
W. T. Shelton, 704
Computer Ref.
1033
CC:
g. F. Hurley H. L. Robinson
PERSON MONITORED Location
EXPOSURE RESULTS
______________R. E. Raines
Bldg. 773 - Along north Date wall near operating area.
4/1/80
Sample 1 2 3 4 5 6
Cone. 0.2 fibers 0.1 fibers
Sampling Time
86 min.
110 min.
Comments A. 1ft'- - Stripping & bagging
P.M. -
"
"
Time-Weighted Average Concentration (TWA) Ceiling Concentration
0.1 fibers > 5 pm/cm3
ALLOWABLE EXPOSURE
TWA
2 fibers > 5 pm/cm3 (qshJ)
Ceiling _
OSHA
UCC UCC
Other Other
COMMENTS
Stripped 48 feet of 3-inch condensate line of suspected asbestos containing insulation which was well wetted. Mr. Raines wore a 3M disposable dust repirator during the stripping and bagging. The stripped insulation was placed in plastic bags for disposal.
UCC 024273
INTERNAL CORRESPONDENCE
__ FllE COPY 1
4EMICALS AND PLASTICS
(Name) ;atior*i py
Mr. W. T. Shelton Building 704 Shop
Mr. G. F. Hurley Mr. G. C. Merz Mr. M. E. Perry Mr. H. L. Robinson
P O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303
D*te November 5, 1979
original-,ng DePiTechnica 1 Center IH/EP
Subiect
Asbestos - Stripping Old Insulation
PROJECT
Survey for asbestos exposure of insulators stripping insulation from a 12-inch by 10-foot reactor column located on the north-west side of Building 773.
DATE OF SURVEY November 2, 1979
SUMMARY AND CONCLUSIONS
Good judgement and proper housekeeping techniques by insulators kept the exposure to asbestos fibers at a minimum. The reactor insu lation was wet down with a water spray can and dismantled with a mini mum amount of handling. Coatings mechanics, Mr. Monin and Mr. Greenlee, wore 3M disposable dust masks, gloves, and coveralls. The stripped material was bagged and labeled for landfill.
The exposures were below the TWA of 2 fibers/cc and a ceiling value of 10 fibers/cc.
RESULTS
Location Building 773 Building 773
Personnel J.R. Monin J.W. Greenlee
Sampling Time-Min.
46 .
43
Exposure Fibers/cc >5 pm
. 0.4
0.1
UCC 024274
Mr. W. T.. Shelton
2
11/5/79
REFERENCES
Volume 38C-29X4-Rla
Asbestos, Dust Determination By Membrane
Filter Techniques Using Phase Contrast Microscopy
REPORT PREPARED BY
G. W. Bott Technical Center Industrial Hygiene Group
APPROVED BY
GWB/sc
UCC 024275
' t'fl i:) .'S
.
ijUMHl ijz
imtcdkjai
.
rnorPCDnKinPMrc _____
`' r
_____
HI F
CHEMICALS AND PLASTICS * P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303
l
i\ ivtn
C C 11 r. n
'cpy tc
Mr. Mr. Mr. Mr.
D. H. R. F. H. L. T. W.
Cook Painter Robinson Souder
Dale Oricjinarmg Subject
January 9, 1979 Technical Center IH/EP Monitoring Insulators
PROJECT
Monitoring insulators for asbestos exposure.
DATE OF SURVEY
December 12 and 13, 1978
DISCUSSION
Messrs. Brad Nester and Charlie Miller, Construction
. insulators, were monitored for asbestos exposure on
December 12 and 13, while removing insulation from piping on the
third level of Building 773, Both men wore respirators during the
operations. On the first day only a small amount of water was
applied to the insulation before removal to minimize the emission
of airborne asbestos fibers. Personnel exposures were 2.8 and 1.3
fibers per cubic centimeters of air (f/cc) respectively. On the
second day of monitoring, December 13, the insulation was thoroughly
wetted with water before, during, and after removal. As a result,
the air concentrations in the breathing zones of the insulators
were reduced to 0.3 and 0.4 f/cc. The OSHA standard for an eight-
hour exposure is 2.0 f/cc.
RECOMMENDATIONS As evidenced by this monitoring, it is essential that extra time be taken to thoroughly wet asbestos-
containing insulation before, during, and after removal. For small stripping operations a portable garden water sprayer can be used.
REFERENCES
UCC C/P Industrial Hygiene Method 38C-29X4-Rla 29CFR 1910.1001
UCC 024276
DATA
Location: Building 773, third level
Date 12/12/78 12/12/78 12/13/78 12/13/78
Employee Brad Nester Charlie Miller Brad Nester Charlie Miller
Sampling Time 0950-1038 0950-1038
1335-1350 1335-1350
Air Cone. Fibers/cc
2.8
1.3
0.4
0.3
REPORT PREPARED BY
W. F. Blythe, Jr. Technical Center Industrial Hygiene Group
WFBJr/sc
W. F."Blythe, Jr.
''
UCC 024277
INTERINJAL CORRESPONDENCE
5H FILE
UNION CARBIDE CORPORATION TECHNICAL CENTER
P.C. BOX 8361, SOUTH CHARLESTON, WV S53Q3
ToiN0mEC. W. Wible ' 770/162
Loc.otiOr"' 511 Area
P.Copy CO D. Gossage - 701/4 C. P. Maxwell - 701/2 R. G. Rowe, M.D. - 791
-- R. E. Sergent - 704
July 15, 1987 "g EM&TS - HS&EA Area Industrial Hygiene
Asbestos Exposure Monitoring
Attached are the results of the non-abatement asbestos exposure monitoring performed on J. A. Ingram and W. S. Ball ingall while pulling computer cable above ceiling tile and through service shafts in Building 770. They were equipped with Half-face Willson R-12 HEPA filtered respirators.
The exposure monitoring indicates that the levels were well below the 0.1 fiber/cc Action Level, established by OSHA for an 8-hour workday (TWAg). However, anyone working above or removing ceiling tile must continue to wear the protective equipment, mentioned above, until enough data is gathered to indicate a problem does not exist, whenever doing this type of work.
Please notify J. A. Ingram and W. S. Ball ingall of their exposure monitoring results as soon as possible. Please have them sign and date this report and return to M. A. Patel at Building 701-330.
If we can be of further assistance, please feel free to call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
Attachment VES:MAP:rab 2488P
Manhar A. Patel
UCC 024278
ASBESTOS EXPOSURE MONITORING
Carp. Ref. W2236
Sanple Type/ Date Enployee Name
7-2-87
Personal/ J. A. Ingram
Sarrpling Tire
Air Cone. Fibers/cc
TOAg Fibers/cc
COWENTS
7hrs 3 min
0.0375
0.033
Collected while pulling carputer cable above ceiling tile and inside of service shafts in Building 770. Job took approx. 4 hours to carpi ete.
7-2-87
Personal/ W. S. Ball ingall
6hr$ 56min
0.0148
0.0128
Collected while pulling carputer cable above ceiling tile and inside of service shafts in Building 770. Job took approx. 4 hours to carpi ete.
ASBESTOS Permissible Exposure Level TWg 0.2 fibers/cc OSHA Action Level 0.1 fibers/cc
2488P
UCC 024279
UNION CARBIDE CORPORATION TECHNICAL CENTER
P.O BOX 83B1, SOUTH CHARLESTON, WV 25303
To INenne) Division Location
Area
L. A. Kapicak 770-240 511
C. P. Maxwell - 701/256 R. E. Sergent- 704/2 P. D. Sherman - 701/254 P. H. Wadi a -770/304
ate October 29, 1986
Originating Dept EM&TS - HS&EA
Area Industrial Hygiene
sublet
Asbestos Area Monitoring
Attached are the monitoring results of the Asbestos Area samples collected in 770-137 on October 23, 1986. The samples were collected to determine the level of airborne fibers present in this lab. Insulators had cleaned, from the floor area. Asbestos containing materials the evening of October 22, 1986.
The samples when counted did not show fiber count any greater then the blank samples and therefore, the results are well below the 0.1 fiber/cc action level, established by 0SHA for an 8-hour workday.
If we can be of further assistance, please call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
Vance E. Stover
Attachment
VES:MAP:rab 1837P
X. (Ui
Manhar A. Patel
UCC 024280
ASBESTOS AREA MONITORING
\
Comp. Ref. W2069
Date
Sampling Time
Air Cone, fibers/cc
COMMENTS..........................
10-23-86 7 hrs 28 min. < 0.003
Collected at the face of the hood behind J. Winkler's desk and very near the point where the Asbestos was lying on the floor.
10-23-86 7 hrs 29 min. ^ 0.003
Collected on top of J. Winkler's desk.
10-23-86 7 hrs 24 min. <0.003
Collected near the double doors that enter the hallway.
ASBESTOS
Permissible Exposure Level
m----------------------
----------------: 0.2 fiber/cc
Action Level 0.1 fiber/cc
OSHA
1837P
UCC 024281
INTERNAL CORRESPONDENCE
i
UNION CARBIDE CORPORATION technca. cent eh?
R.O BCJX 036 1 . !iOU r'-> CHARLESTON. WV Ez'ISBC
BUSINESS CONFIDENTIAL A. F. Terry 704 Shop 511
C. P. Maxwell R. G. Rowe, M.D. C. L. Ruddle R. E. Sergent
July 24, 1986 HS&EA Industrial Hygiene Asbestos Exposure Monitoring
Attached are the results of the Asbestos monitoring done in Building 770 on June 23, 1986. R. E. Raines and R. P. Hess were monitored while they removed approximately 15 feet of Asbestos from a steam line inside of the S-5 air handler during off-hours. They were equipped with disposable coveralls, boots, disposable dust mask, gloves and head cover.
The air handler was shut down and the area was barricaded. Plastic was put on the floor, under the steam line, and excess water was used for wetting down the insulation. The Asbestos insulation, as well as the plastic was removed very diligently. The floor was flooded with water and vacuumed.
The sample results show that for the very short sampling time, the potential exposure to Asbestos was low. If it was averaged over an 8-hour period, it would be well below the permissible exposure level of 2 fiber/cc of air. An 8-hour average was not established because both R. E. Raines and R. P. Hess indicated that they worked with insulation, that may have contained Asbestos, earlier in the day before this job was done.
Please inform R. E. Raines and R. P. Hess of their exposure results and if we can be of further assistance, please call us on extension 4779 or 3750,
WORK BY:
APPROVED BY:
Vance E. Stover
VES/jac 1512P
Manhar A. Patel
UCC 024282
K
* Comp Ref W/1999
Date 6-23-86
6-23-86
6-23-86
Sample Type Employee Name Personal/ R.E. Raines
Personal/ R. P. Hess
Area
ASBESTOS EXPOSURE MONITORING
Sampling Time
Air Cone Fibers/cc
TWAg Fibers/cc Comments
59 min
0.928
------------
Collected while
removing and bag ging 15 feet of Asbestos from 770-S-5 Air Handler
58 min
1.35
--------------
Collected while removing and bagging 15 feet of Asbestos from 770-S-5 Air Handler
1 hr 3 min
0.420
-------------
Collected inside of Air Handler about waist high setting on precipitron.
Asbestos Permissible Exposure Levels* TWAg 2 fibers/cc OSHA Ceiling 10 fibers/cc
* OSHA Guidelines in effect at time of monitoring.
1512P
UCC 024283
INDUSTRIAL HYGIENE MONITORING FOR:
ASBESTOS
v. * `
0
BUSINESS CONFIDENTIAL
Computer Ref: W-1500 Bate: Nov. 18/ 1983
To:
W. T. Shelton, 704 SHop
c c: R. E. F'eele/ 701--334 R. G. Roue, M.D.> 791
PERSON MONITORED:
J. W. Greenlee
LOCATION:
770 Fan Room
EXPOSURE RESULTS
Sample No.
Cone.
Sampling Time
Date:
11/8/83
Comments
1
0..2 9 fibers/cc
134 Minutes
Personal sample
0. 06 fibers/cc
23 Minutes
Area sample
3 0.03 fibers/cc 97 Minutes
Area sample
4 0.05 fibers/cc 97 Minutes
Area sample
Time-Weighted Average Concentration <TWA): Ceiling Concentration:
ALLOWABLE EXPOSURE
TWA:
.5 fibers/cc
Ceiling:
-
_X OSHA ______OSHA
______UCC ______UCC
______Other ______Other
COMMENTS
Personal and area samples were collected while Mr. Greenlee stripped insulation from a steam line in Building 770 Fan Room. The line was located on S-5 precipitron. Mr. Greenlee stripped six feet of insulation from a two-inch steam line outside the precipitron and twenty feet of insulation from the line inside the precipitron. Mr. Greenlee wore a respirator/ gloves/ paper suit and hood while per forming his work and during the cleanup operation. The area was barri caded and a sign posted. Please inform IH Department of the next stripping job in this area and inform Mr. Greenlee of his exposure. Please note the change in OSHA standard from 2 fibers/cc to . 5 fihers/cc.
WORK
APPROVED BY:
UCC 024284
X 'SIj-J
Manhi.ii' A. Patel
J CARHIO CONFIDENTIAL L
" INDUSTRIAL HYGIENE MONITORING FOR
ASBESTOS
FILE COPY
TO: W. T. Shelton, 704 Shop
Computer Ref. W-1207
Date
July 30, 1981
cc: R. E. Peele, 701-334 H. L. Robinson, 701-401
PERSON MONITORED Location
J. W. Greenlee
Bldg. 770-137
Date
07/24/81
EXPOSURE RESULTS
Sample No.
Cone .
fibers >5 pm/cm3
Sampling Time
52 Minutes
2
Comments
Insulator stripping approx. 60 feet of insulation from a 1/2-inch steamline.
3
4
5 6
Time-Weighted Average Concentration (TWA) Ceiling Concentration
< ,1 fibers > 5 pm/cnP
ALLOWABLE EXPOSURE
TWA
2 fibers > 5 pm/cm3
Ceiling __________________________
. X OSHA
OSHA
UCC UCC
_____Other Other
COMMENTS The 52 minutes sampling time represents the total job.
APPROVED BY UCC 024285
Manhar A. Patel
CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR
TO: W, T. Shelton, 704 Shop
ASBESTOS
Computer R6f. W-1207
Date
July 30, 1981
cc:
R. E. Peele, 701-334 H. L. Robinson, 701-401
PERSON MONITORED Location
Bldg. 770-137
J. R. Monin Date
07/24/81
EXPOSURE RESULTS
Sample No.
Cone.
fibers r 1 .7 >5 pm/cm* 1
2
Sampling Time
51 Minutes
Comments
Insulator bagging stripped insulat ion.
3
4
5
6
Time-Weighted Average Concentration (TWA) < .1 fibers > 5 gm/cm Ceiling Concentration
ALLOWABLE EXPOSURE
TWA
3 2 fibers > 5 aro/cm
Ceiling __________________________
X OSHA OSHA
_____UCC UCC
Other Other
COMMENTS The 51 minutes sampling job represents the complete job.
WORK BY
Ruth Clise
APPROVED BY UCC 024286
Manhar A. Patel
INTERNAL CORRESPONDENCE
1 FILE.CDPrt
HEMICALS AND PLASTICS * P. C. BOX 6361, SOUTH CHARLESTON, WEST VIRGINIA 25303
(Nam;) vision caiiori
'PY
Mr. W. T. Shelton Building 704-Shop
Ms. M. M. Gilbert Mr. M. E. Perry Mr. H. L. Robinson Dr. F. G. Young
Dare March 26, 1980
c 3,r,nt ,g c.p, Technical Center IH/EP
; bfd
Asbestos Monitoring in Building 770
PROJECT
Monitor exposure of insulators to asbestos during the removal of insulation tape from tubing in Room 237 of Building 770.
DATE OF SURVEY March 19, 1980
DISCUSSION
Services insulators R. E. Raines and J. W. Greenlee wore per sonal samplers while removing asbestos tape from various lines in Room 237 of Building 770. An area sample was also taken on a desk in the northwest corner of the room. Due to asbestos tape's disin clination to emit airborne asbestos fibers, the tape was not wetted with water during removal. However, respirators were worn and the area was barricaded in accordance with OSHA regulations. All samples indicated concentrations of less than 0.1 fibers/cubic centimer of air (f/cc).
The current OSHA standard sets a ceiling limit for a 15~minute exposure of 10 f/cc and a limit of 2 f/cc for an eight-hour timeweighted average exposure. Further monitoring of asbestos tape removal will not be required.
REPORT PREPARED BY W. F. Blythe, Jr.
APPROVED BY G. F. Hurley
WFBJr/sc
UCC 024287