494 CHAPTER 19 1958 Guide Table 5. Heating Capacities and Cfm of Branch Ducts in Extended Plenum Perimeter Systems :{-SECTION A. SIDE TAKEOFF TO 5-INCH ROUND PIPE FOR SIDEWALL, FLOOR AND BASEBOARD DIFFUSERS Extended Plenum Pressure 0.18 in. Static at 160 F Furnace Plenum Pressure 0.15 in. Static at 170 F No. of Elbows Actual Length from Extended Plenum to Diffuser--Feet 5 10 15 20 25 30 35 40 45 50 55 60 <f i 2V 3 .4 5 6 Btuh Cfm Btuh Cfm Btuh Cfm Btuh Cfm Btuh Cfm Btuh Cfm Btuh Cfm 8960 8100 7310 6550 5900 5310 4800 4330 3900 3510 3170 2850 97.2 93.1 89.4 88.0 83.0 81.2 77.7 75.5 73.1 71.1 69.3 67.8 8070 7290 6580 5950 5400 4880 4400 3980 3550 3200 2900 2620 88.4 85.2 82.2 79.3 76.9 74.6 72.5 70.7 68.9 67.1 65.7 64.2 7340 6650 6020 5460 4950 4500 4070 3680 3300 2980 2680 2410 81.1 78.6 76.0 73.9 71.9 70.0 68.2 66.6 64.1 63.7 62.3 61.0 6810 6180 5600 5070 4610 4200 3800 3420 3080 2770 2480 2230 75.0 73.0 71.0 69.2 67.3 65.8 64.4 63.1 61.7 60.2 59.0 58.2 6350 5750 5210 4740 4300 3900 3530 3180 2870- -2570 2300 2070 70.4 68.8 67.0 65.4 64.0 62.5 61.1 60.0 -58.8 57.7 56.7 55.9 5970 5400 4900 4440 4040 3670 3330 2990 2770 2410 2160 1930 65.2 64.8 63.2 -62.0 60.7 59.4 58.3 57.4 56.2 55.3 54.4 53.7 5660 5120 4630 4190 3800 3430 3100 2800 2520 2270 2040 1800 63.0 61.5 60.2 59.1 58.0 56.9 65.9 55.1 54.0 53.0 52.2 51.8 Note: Where any of the first three runs from the extended plenum exceed'20 ft and 3 elbowB count 3 extra elbows for that run. The Equivalent Length Values used and included in calculating this table are: Diffuser and Boot = 35 ft; Each Elbow = 12 ft; Side Takeoff = 20 ft. Tapered Extended Plenum Starting Collar. SECTION B. TOP TAKEOFF TO 5-INCH ROUND PIPE FOR SIDEWALL, FLOOR AND BASEBOARD DIFFUSERS Extended Plenum Pressure 0.15 in. Static at 160 F Furnace Plenum Pressure 0.16 in. Static at 170 F No. OF Elbows Actual Length from Extended Plenum to Diffuseb--Feet 5 10 15 20 .25 30 35 40 45 50 55 60 0 1 2 3 ;4 5 6 Btuh Cfm Btuh Cfm Btuh Cfm Btuh Cfm Btuh Cfm Btuh Cfm Btuh Cfm 7070 6400 5800 5260 4800 4350 3940 3550 3190 2870 2580 2310 77.8 75.6 73.4 71.4 69.5 68.0 66.4 .64.8 63.4 62.0 60.6 59.5 6570 5970 5400 4890 4430 4010 3640 3290 2950 2650 2380 2140 72.6 70.8 68.9 67.2 65.6 64.2 62.8 61.5 60.3 59.0 58.0 57.0 6180 5610 5080 4590 4160 3770 3410 3080 2770 2480 2210 2000 68.4 66.8 65.2 63.7 62.3 61.1 60.0 58.7 57.6 56.4 55.3 54.4 5800 5250 4750 4310 3900 3540 3200 2890 2600 2340 2100 1870 64.4 63.1 61.8 60.5 59.3 58.3 57.1 56.3 55.5 54.7 53.9 53.2 5490 4960 4500 4080 3700 3340 3020 2720 2440 2200 1970 1750 61.2 60.0 58.8 57.8 56.7 55.8 54.9 54.1 53.3 52.6 51.9 51.1 5200 4710 4280 3870 3510 3180 2880 2580 2310 2060 1830 1640 58.5 57.5 56.5 55.5 54.5 53.7 52.9 52.1 51.4 50.7 50.0 49.5 5000 4520 5100 3700 3350 3010 2700 2440 2160 1910 1700 1551 56.0 55.0 54.0 53.4 52.4 51.7 51.0 50.5 59.7 49.1 48.6 48.1 Note: Where any of the first three runs from the extended plenum exceeds 20 ft and 3 elbows, count 3 extra elbows for that run. The Equivalent Length Values used and included in calculating this table are: Diffuser and Boot = 35 ft; Each Elbow = 12 ft; Top Takeoff -- 50 ft. Tapered Extended Plenum Starting Collar. Warm Air Heating Systems 495 Table 5. Heating Capacities and Cfm of Branch Ducts in Extended Plenum Perimeter Systems (Continued)- SECTION-C. SIDE-TAKEOFF TO 5-INCH ROUND PIPE FOR BASEBOARD DIFFUSERS ONLY, Extended Plenum Pressure 0.18 in.JStatic of 160 F Furnace Plenum Pressure 0.15 in.. Static at llO.P No. of Elbows . Actual Length from Extended Plenum to Dxffuseb-^Fbet . 5 10 ,15 20 25 30 35 40 45 50 55 `60 0 1 2. 3 ... 4 .5 6 Btuh ; , Cfm Btuh ; Cfm c Btuh Cfm Btuh Cfm Btuh Cfm Btuh. Cfm . Btuh Cfm 9800 9100 8430 7820 7230 6700 6200 5730 5320 4920 4550 4210 106.6 104.4 102.3 100.3 98.5 96.8 95.0 93.1 91.7 90.0 88.5 87.2 9230 8550 7930 7360 6800 6300 5830 5400 5000 .4620 4260 3960 100.4 98.7 97.0 95.3 93.7 92.0 90.4 88.9 87.6 86.2 84.9 83.8 8740 .8100 ,7500 .6960 6420 5960 5510 5110 4730 .4390 4050 3750 95.5 93.8 92.2 90.6 89.4 88.0 86.5 85.2 84.0. 82.8 81.6 80.6 .8300 7690 7130 6600 6110 5680 5240 4850 4500 4170 3840 3560 91.0 89.5 88.0 86.7 85.5 84.2 83.0 82.0 80.9 .79.8 78.8 77.9 7930 7350 6800 .6290 5830 5400 5000 4620 4270 3940 3630 3370 86.8 .85.5 84.2 83.3 82.0 81.0 80.0 79.1 78.0 77.0 76.1 75.3 .7600 7020 6500 6020 5580 5160 4770 4410 4080 3770 3470 3190 83.6 82.5 81.3 80.2 79.1 78.1 77.1 76.4 75.3 74.4 73.5 72.8 7300 6760 6260 5780 5350 4950 4560 4200 3900 3580 3300 3040 80.4 79.5 78.4 77.5 76.3 75.3 74.4 73.5 72.8. 72.0 71.2 70.6 Note: Where any of the first three runs from the extended plenum exceeds 20 ft and 3 elbows, count 3 extra elbows for that run. The Equivalent Length'Values used and included in calculating this table are: Diffuser and Boot =*' 100 ft; Each Elbow = 14 ft; Side Takeoff = 20 ft. "' ' Tapered Extended Plenum Starting Collar. SECTION D. TOP TAKEOFF TO 6-INCH ROUND PIPE FOR BASEBOARD DIFFUSERS ONLY Extended Plenum Pressure 0.18 in. Static at 160 F Furnace Plenum Pressure 0.15,in. Static at 170 F No. OF Elbows Actual Length from Extended Plenum to Diffuser--Feet 5 10 15 20 25 30 35 40 45 50 55 : 60 0 _ 1 . Btuh Cfm BtuhCfm 2 -- 3 --_________ _ 4 -- 5 Btuh Cfm Btuh . Cfm Btuh Cfm . Btuh Cfm 6 ---- ------------- - Btuh Cfm 8700 8050 7450 6900 6400 5910 5470 5160 4670 4300 4000 3720 95.0 93.2 91.7 90.0 88.6 87.3 86.0 84.7 83.5 82.4 81.3 80.2 8260 7640 7090 6560 6080 5630 5200 4820 4470 4140 3830 3530 90.2 88.8 87.5 86.2 85.0 83.7 82.6 81.7 80.4 79.4 78.4 77.5 7880 7290 6750 6250 5800 5380 4980 4590 4260 3940 3620 3340 86.3 85.0 84.0 82.9 81.7 80.5 79.6 78.7 77.6 76.7 75.8 74.9 7560 7000 6470 5980 5540 5130 4740 4380 4060 3730 3430 3170 83.0 82.0 81.0 79.8 79.0 78.0 76.9 76.0 75.1 74.2 73.3 72.5 7260 6700 6200 5740 5290 4900 4510 4160 3850 3560 3290 3020 80.0 79.1 78.1 77.2 76.2 75.2 74.3 73.5 72.7 71.9 71.0 70.2 7000 6470 5970 5490 5070 4700 4320 3990 3600 3400 3120 2870 77.3 76.3 75.4 74.5 73.6 72.8 71.9 71.2 70.2 69.3 68.7 68.1 6770 6230 5740 5290 4890 4500 4140 3820 3520 3240 2980 2760 74.6 73.8 73.0 72.2 71.3 70.5 69.8 69.0 68.3 67.5 66.9 66:1 tk firat three runs from.the extended plenum exceeds 20 ft. and 3 elbows count 3 ft; P.^h^ivalent.Values used and included in calculating this table are; Diffuser and Boot =' 100 wn JUbow = H ft; Top Takeoff - 50 ft. * Tapered Extended plenum Starting Collar,