Document J3Dpv7aL4B9ayygOE6bk1XEdB

Boilers and Engines The Brownell Company Dayton, Ohio Sales Representatives in All Sections of the Country Steel Heating and Power Boilers, Feed Water Heaters, Tanks, Breechings, Stacks, Boiler Castings, Steel Plate Construction and Steam Engines. Since 1855, when The Brownell Co. was established, this company has been manu facturing a complete line of High Grade Boilers and other equipment. The Brownell Smokeless Firebox Boiler is designed and constructed to burn any kind of fuel economically and with out smoke. Brownell Firebox Boilers are mechanically correct and insure long life. Brownell Heating Boilers have generous and properly designed fireboxes, permitting complete combustion and high efficiency. Brownell ratings are very con servative, only the parts of boiler below the normal water level and coming in actual con tact with the hot gases being considered as effective heating surface. Brownell Boilers will carry the number of square feet of direct radiating surface or equivalent given in opposite tables if sufficient radiation is installed to heat the building to the required temperature. Brownell Firebox Heating Boilers are regularly built according to the A. S. M. E. Code for 15 lb. working pressure but will be furnished for pressures up to 100 lb. at an increased cost. Bronvnell Return Flue Portable Direct Draft Type Bulletin B-6A Brownell Brick-set Firebox Boiler Direct Draft Type Bulletin B-6 Brownell Return Flue Portable Smokeless Type Bulletin B-CA- 194 Brownell Brick-set Firebox Boiler Smokeless Type Bulletin B-6 The Brownell Company Boilers and Engines BROWNELL DIRECT DRAFT PORTABLE BOILERS Boiler No.............. ............... 407 408,409 Capacity--Steam. Sq. F t......... zwx 2900,3500 410 400C 411 4500 412 5000 413 5500 414 6000 415 7000 416 8000 417 418 419 420 i 421 1 422 423 424 9500 II00C 13000 1500017500 2ooa 25000 28000 Capacity--Water. Sq. Ft......... 410f 4800 580C 6600 7400 8300 9100 9900,11600 13200 15700 18200 21500 2480028500 32000 40000 45000 Approximate Weight................. 690C 7400 6300 9000 9800 10600 I320C 14I0C 15900 17300 20400 22000 24000 25700 280a 31000 37000 40000 Diam. of Boiler, In............ 48 48 48 54 54 54 60 60 60 60 66 66 72 72 78 78 84 84 Length Boiler Overall. Ft.. In.. 8-6 9-6 10-6 10-0 ll-C 12-0 12-6 13-6 14-0 15-6 15-J 17-8 15-10 17-4 17-10 19-10 20-0 22-0 Heating Surface. Sq. Ft........... 293 333 373 427 487 537 614 670 698 781 936 1061 1224 1356 1539 1796 2227 2478 Size of Steam. In......................... 6 6 6 6 6 6 7 7 7 7 8 8 8 8 8 8 10 10 Sire of Return. In...................... 4 4 4 4 4 4 5 5 5 5 6 6 6 6 6 6 6 6 Height of Water Line. In......... 69 69 69 76 76 .76 78 78 78 78 87 87 92 92 92 92 98 98 Height. Floor to Top of Shell. In................................................. 84 84 84 91 91 91 95 95 95 95 108 108 109 109 110 no 116 116 Space Required to Open Rear Doors. In.. ............................... 25 25 25 28 26 28 30 30 30 30 35 35 37 37 40 40 43 43 Diam. Breeching. In.................. 22 22 22 24 24 24 26 26 28 28 30 32 34 34 36 36 40 40 Diam. Stack. In........................... 20 20 20 22 22 22 24 24 26 26 28 30 32 32 34 34 38 38 Min. Height of Stack. Ft......... 50 50 55 55 55 60 60 60 65 65 65 70 70 70 80 90 90 100 Diam. Breeching, 2 Boilers. In. 30 30 30 34 34 34 38 38 40 40 44 46 50 50 62 52 56 56 Diam. Stack. 2 Boilers. In.. . 28 28 28 31 31 31 34 34 36 36 40 42 46 46 48 48 54 54 Minimum Height Stack. 2 Boilers. Ft................................. 60 60 65 65 65 70 70 70 75 75 75 80 80 80 90 100 100 (00 BROWNELL SMOKELESS PORTABLE BOILERS 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 Capacity--Steam. Sq. Ft......... |300C 35a 400C 45a 5oa 55a 60U 65a 75a 85a loax 1200014000160a 1800020000250a 30000 500C 58a 66a 74a 83a 9ia 99a 107a 124a i4oa 16500 1980023100 264a 29700i33000,400a 48000 Approximate Weight................. 78a 86a 93a 104a ma U90C 145a 153a i69a i78a |209a 229a 25000265a 28800 300a 370a 43000 48 48 48 54 54 54 60 60 60 60 66 66 72 72 78 78 84 84 Length Boiler. Overall. Ft.. In. 8-7 MC 10-K 10-7 11-7 .12-7 12-7 13-7 15-1 16-1 15-9 17-9 16-6 17-t !7- 18-6 20-1 24-1 307 381 405 472 526 579 631 687 766 822 922 1062 1255 1370 1529 1601 2090 2655 6 6 6 6 6 6 7 . 7 7 7 8 8 8 8 8 8 10 to 4 4 4 4 . 4 4 5 5- 5 5 6 6 6 6 6 6 6 6 Height of Water Line. In......... 69 69 69 76 76 76 78 78 78 78 87 87 92 92 92 92 103 103 Height, F loor to i op of Shell. 84 84 84 92 92 92 95 95 95 95 108 108 109 109 110 110 118 118 Space Required to Open Rear 75 75 25 28 28 28 30 30 30 30 35 35 37 37 42 42 44 44 22 22 22 24 24 24 26 26 28 28 30 32 34 34 36 36 40 40 20 20 70 22 22 22 24 24 26 26 28 30 32 32 34 34 38 38 50 55 55 55 55 60 60 60 65 65 65 70 70 70 80 90 90 100 30 30 30 34 34 34 38 38 40 40 44 46 50 50 52 52 56 56 Diam. Stack. 2 Boilers. In.. . . 28 28 28 31 31 31 34 34 36 . 36 40 42 46 46 48 48 54 54 Ft......................................... 60 65 65 65 65 70 70 70 75-1 75 75 80 80 80 90 too too 110 BROWNELL DIRECT DRAFT BRICKT-SET BOILERS 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 9a 105C 120014a 170020002000260030X 350040a 45a 55a 65a 75a 8700100a t.ioa i2ua 14000 Capacity--Water. Sq. Ft.___ isa 17a 200023a 280) 33003300.430030a 580066a 74a 9ia 107a 124a 144a i65a 18200 i98a 231a ?m 300C '320036a 420048a 520 3600600 700078a 86a wa uoa 135a i48a 160a 174a 186a 204a 30 30 30 36 36 36 42 42 42 48 48 48 54 54 60 a 66 66 72 72 6-6 7-6 8-6 7-6 W) 10-6 B-6 10-0 11-6 10-6 12--C 13-6 14--C 16-6 15-6 18-0 16-0 18-0 16-0 18-0 Heating Surface. Sq. Ft...... 113 128 143 193 Z31 268 269 317 364 390 444 499 573 683 755 887 971 1097 1183 1343 3Size of Steam. In....................... 3 4 44466666 / 7 7 7 7 8 8 8 8 Size o! Return. In...................... m 2>/i 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 ,6 6 6 Water Boilers......................... 1-6 1-6 1-6 1-6 1-6 1-6 2-5 2-6 2-6 2-6 2-6 2-7 2-7 2-7 2-7 2-8 2-8 2-1C 2-10 2-10 Height of Water Line. In........ 53 53 53 59 59 59 61 61 61 65 65 65 67 67 75 75 80 a 85 85 Height Floor to lop ot Bnck Work. In.................................. 70 70 70 77 77 77 83 83 83 90 90 90 96 Diam. Breeching, In................. 12 14 16 16 18 18 20 20 22 22 24 24 28 12 12 14 14 16 16 18 18 20 20 22 22 26 40 40 40 40 40 45 45 45 45 45 50 50 50 26 28 30 30 34 36 38 24 26 28 28 30 32 34 96 108 108 114 114 120 120 28 32 32 32 32 36 36 26 30 30 30 30 34 34 50 55 55 60 60 60 a 38 40 40 40 42 44 46 34 36 36 36 38 40 42 Min. Height Stack, 2 Boilers. Ft.............................................. 50 50 50 50 50 50 55 60 60 70 70 70 70 70 BROWNELL SMOKELESS BRICK-SET BOILERS Approximate Shipping Weight......... Heating Surface. Sq. Ft.................... Size of Steam. In.................................. Size of Return. In................................. 107 26a 43a 6ta 42 9-10 309 6 4 108 109 3ia 36a 5100 59a 67a 72a 42 42 11-4 12-11 359 409 66 44 110 111 40a 47a 66a 78a 84a 9ia 48 48 12-4 13-10 448 506 66 44 112 113 114 115 116 117 118 119 120 55a 65a 75a 85a 10000 nsa 1300 1400 1600 9100 107a 124a 140a i65a 1900 2150. 2310 2640 98a 12300 i36a 1600 174a 1940 2100 2240 2430 48 54 54 60 60 66 66 72 72 15-4 15-10 18-4 17-10 20-4 18-4 20-4 18-4 20-4 563 643 756 851 987 1074 1204 1303 1468 77 77 7 8888 5 5 5 5 5 6 6 6- 6 Size Supply and Return--Water 2-6 2-6 2-6 2-6 2-7 2-7 2-7 2-7 2-8 2-8 2-10 2-10 2-10 2-10 61 61 61 65 65 65 67 6/ 75 75 80 80 86 86 Height Floor to Top of Brick Work, In........... 82 82 82 89 89 89 95 95 107 107 113 113 119 119 Space Required to Open Rear 22 22 22 25 25 25 28 28 30 30 35 35 37 37 22 22 24 24 27 27 30 30 34 34 36 36 38 38 20 20 22 22 24. 24 28 28 32 32 34 34 36 36 50 50 50 50 55 55 60 60 60 a 70 70 70 70 26 30 34 34 36 36 38 40 42 42 44 46 48 50 26 28 30 30 32 32 34 36 38 38 40 42 44 46 Min. Height Stack. 2 Boilers. F t.. . a 60 60 60 60 60 70 70 70 75 75 60 a 80 195