(540) Electric Furnaces and Ovens
Part VI, 1930-31 Mechanical Catalog
GENERAL ELECTRIC COMPANY
General Office: SCHENECTADY, N. Y,
Manufacturer of Complete Electrical Power Equipment and Supplies
BRANCH OFFICES: See page 13
G-E DIRECT HEAT ELECTRIC FURNAC_
A complete line of furnaces for steel harden ing, drawing, annealing and carburizing; a new continuous AIR-SEALED vitreous enameling furnace; furnaces for tinning and galvanizing; brass and copper annealing, white-metal melting; and completely erected furnaces for all kinds of heat treating and processing are now available.
Many of these designs are the result of years of experience with electric furnaces in G-E factories.
means, and it permits complicated structures to be made from simple parts at a considerable saving in cost.
STANDARD FURNACES:
For general heat-treating, tool room installations, small shops, etc., a line of standard furnaces has been developed, hundreds of which are in daily use. They include box type, with hearth widths from 12 inches to 36 inches, vertical, cylindrical, pot type
Standard G-E Direct Heat Electric Furnaces
Electric Resistance Furnaces for Heat Treating
Temperatures up to 1850 F. can be maintained con
tinuously without deterioration of the non-oxidizing
nickel-chromium alloy ribbon resistor. Automatic
temperature control insures accurate, uniform tem
peratures without over-heating and with minimum
power consumption.
for lead and cyanide hardening, and melting pots for lead, tin, solder and babbitt, which use the direct heat principle of immersing a helicoil sheath wire cast-in unit directly in the metal to be melted.
Stocks of these furnaces are always maintained. These furnaces are arranged for either alternating or direct current and operate on standard circuit voltages.
COPPER BRAZING IN ELECTRIC FURNACES:
Copper brazing in an atmosphere of protective gas is a process developed in the G-E Research Laboratory
The design of heating units provides an even dis tribution of heat throughout the furnace chamber without hot or cold spots.
for use on G-E products. Turbine parts, molds, dies, refrigerator units and many other parts are being successfully joined. This process is a convenient method of uniting parts by a strong alloy weld, which would be exceedingly difficult to accomplish by other
G-E AIR DRAWING OVEN:
The proper drawing of tools, dies, and other steel parts after hardening is an important step in their production. Perfect uniformity in heating, with close control of temperature is essential to secure high qual
ity. The electrically heated,
automatically controlled oven
is ideal for this work because
it fulfills the requirements to a
degree impossible of attainment
with a fuel heated oven, and
insures exact duplication of re
sults as often as may be de
sired. The steel comes out clean,
the temper is uniform through
out, and where surface color is
desired, the right shade is as
sured. These are the results of
uniform heating in a clean at
mosphere at temperatures main
tained automatically within plus
Continuous Electric Furnace for Copper Brazing Evaporator Parts
Or minus 5 degrees.
(See pages 13, 480, 597 608, 796 and 797 for additional products ofthis Company)
Type AD Air Drawing Oven
(608) Air and Gas Compressors
Part VIII. 1930-31 Mechanical Catalog
GENERAL ELECTRIC COMPANY
General Office: SCHENECTADY, N. Y.
Manufacturer of Complete Electrical Power Equipment and Supplies
BRANCH OFFICES: See page 13
G-E AIR COMPRESSORS:
energy imparted to the air by the high peripheral
The G-E center gear type motor driven air compressors were made for supplying com pressed air for operation of brakes, whistles, and other pneumatic devices.
Type CP compressors are for use on direct-cur
speed of the impeller instead of dissipating such energy in heat. Owing to the absence of valves and rubbing surfaces there is no possibility of leak age with the subsequent decrease of efficiency that characterizes all forms of positive pressure blowers.
rent circuits. Type CPT compressors are for use on
three-phase alternating-current circuits. Type CPQ
are for use on two-phase circuits.
1TM Type CP .and CPT-27 and 28 direct-
current and alternating-current sets, respec
tively, are furnished with three-wheel trucks, 6 ft. 9 in. long, 2 ft. S
in. wide and 3 ft. 9 in.
high, complete with con
trol, reservoir (18 x 60 in.), 25-ft. rubber hose . with nozzle, safety valve, stop-cock, coupler socket
mounted on truck and coupler plug, all piped and wired ready for operation.
Types CP and CPT-
Portable Air Compressor Outfit
26, 100 to 110 cu. ft., direct-current and alter
nating-current sets, can also be furnished mounted on
mine type car complete with control and all accessories.
Turbine Driven Centrifugal Gas Ex hauster for 10,000 Cu. Ft. of Gas per
Min. against 354-Lb. Pressure
Centrifugal Compressors are usually driven by steam turbines which are now available as high efficiency, high speed units or electric motors of the variable and con stant speed type. Where higher speeds than are available from direct-connected drivers are necessary, speed-increasing gears are interposed between them and the compressors, thus permitting of greatly ex tended capacity. The use of high' speed drivers with either direct-connected or with speed-increasing gears results in high over-all efficiencies, low up-keep cost, small space occupied, ab
sence of noise and vibration. These
CENTRIFUGAL COMPRESSORS:
features, together with the greater dura bility, low maintenance and extreme
Centrifugal Compressors are built in single and multi simplicity, are
stage types.
' worthy of the
The single stage compressor consists of a rotating consideration of impeller mounted on the shaft of the driver and sur the engineer. rounded at its periphery by diffuser rings. These are General Elec
enclosed in a circular casing somewhat similar to that tric centrifugal air
of a centrifugal pump. The intake is located at the compressors are
end center while the discharge may be located in any one of eight positions about the circumference of the circular casing.
The multi-stage centrifugal compressor consists
operated success fully in the follow ing applications.
Oil-fired fur
Motor Driven Single Stage Compressor for 3000 Cubic Feet of Air at 9-lb. Pressure with Speed-Increasing Driven by 170 HP Induction Motor
Gear
simply of two or more impellers and diffusers in series. naces, gas-fired furnaces, pulverized coal-fired furnaces,
Each stage is separated by a suitable diaphragm which agitation of liquids, cupola blast, pneumatic conveying,
efficiently directs the air or gas from one stage to the water gas generators, blast furnaces, Bessemer con
next. Diaphragms are provided with suitable inter verters, copper blast furnaces, copper converters, gas
stage packings and where these machines
exhausting, and gas boosting.
are used to handle gas suitable packing
These units are manufactured in capacities up to
is provided on each end where the shaft
85,000 cu. ft. of free air per minute against 35 lbs. pres
enters the casing. Tar drains are also
sure, and may be driven by either motors or turbines.
provided on these units for gas service.
For complete information on these outfits refer to
One of the striking features of cen
our nearest Sales Office.
trifugal compressors is the high efficiency which they
are capable of maintaining
for years without renewals
or appreciable expense for
maintenance. This high
efficiency is due to the fact
that unlike the ordinary fan or blower
they are capable of recovering in the
form of pressure nearly all the velocity
Turbine Driven 50,000 Cu. Ft. Blast Furnace Blowers
(See pages 13. 480, 540, 507, 796 and 797 for additional products of this Company)
Mechanical Catalog
Consisting of uniformly presented and illustrated catalog information, conveniently classified, describing the products of manufacturers of mechanical equipment 'With DIRECTORY OF MANUFACTURERS OF INDUSTRIAL EQUIPMENT, MATERIALS AND SUPPLIES
A specialized, .classified and cross-indexed list. with names and addresses inserted free of charge
1930-31
TWENTIETH ANNUAL VOLUME
ISSUED OCTOBER 1930
.Published By
THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS
29 WEST 39th STREET, NEW YORK, N. Y.