Document J3D1j9mRk7QambDbng4nY4rKX

43--Fire Protection tinguishers is divided into (a) water solution extinguishers, (b) drv-chemical, caibon di oxide, and liquefied-gas extinguishers, and (c) dry-powder extinguishers Some vaporizing liquid extinguishers, such as those containing carbon tetiachlonde 01 chloiobromo-methane, are excluded as they are not lecommended because of their toxic pioperties The proper method of opeiation and maintamance of these extinguishes are described m Figs 43-14 through 43-24, and then chaiactenstics are summarized m Fig 43-13 Water solution extinguishers Fire extinguishers that use watei m watei solutions include pump tank, cartridge actu ated,0 soda-acid, stoied pressure, loaded stieam (often including a wetting agent), and foam* (see Figs 43-14 through 43-18) These extinguishers are effective against Class A flies liecause of the quenching and cooling effect of watei The cooling effect of all but the foam extinguisher can be mci eased if the operator extends his forefingei ovei the edge of the nozzle to cieate a sprav Foam pri marily extinguishes Class B fires bv smother ing The loaded stieam extinguisher can also be used against Class B fires because of the chemical action of the alkah-metal-salt, how ever, it has limited effectiveness These units cannot be used on flies in oi neai electrical equipment since thev can pioduce a shock hazard to the opeiator One important maintenance item on all wa ter extinguishers is to inspect the nozzle fre quently foi foieign particles that may pi event discharge, such as dirt, match sticks, and paper The piessuie relief hole in the cap of soda acid, gas cartndge, and foam units must also be fiee from obstiuction as it is designed to release anv lesidual pressuie that may in jure a workei when he is lemoving the cap before rechaigmg In locations exposed to fieezmg temperatuies, extinguishers must lie installed in heated cabinets (Fig 43-19). oi chaiged with a nonfreezing solution Howevei, antifieeze oi salt solutions should not lie used unless the equipment has been designed foi such use For example, some chemicals cause lapid corlosion when used in stainless steel units Water-base extinguishing equipment that cannot be protected from freezing tempera 1350 tures can sometimes be kept usable by the addition of calcium chloride or patented chemicals Except for loaded stream ex tinguishers, which use a special alkali-metalsalt solution, the pump tank, cartndge op erated, and stored-piessuie water extinguishes can be protected against freezing by calcium chloude or by special antifreeze charges rec ommended bv the manufacturer Calcium chloride solutions are good con ductors of electncity and therefore especially dangerous if applied to live electrical ap paratus Solutions have high corrosivitv and should include a corrosion mhibitoi When charging any extinguisher with an antifreeze solution, the chemical should be thoroughly dissolved m warm watei in a sepa rate container and then poured into the extinguishei through a fine stiamer to remove any foreign pai tides that may clog the unit Gieater care must be given m maintaining extinguishes containing antifreeze solutions, because they mav corrode moie easilv than with plain water In recharging, all parts In cluding the hose and nozzle should be thor oughly flushed with plain watei Be sure that all the plain water is diained off to pi event freezing and clogging Table 43-D shows the appioximate tempeutuies above which varying stiengths of 211-gal calcium chloride solution will give piotection against fieezing At legulai intei vals, solu tions should be tested with a hvdiometei for contoimitv to the figuies Dry-chemical, carbon dioxide, and liquehed-gas extinguishers Dry-chemical extinguishers The di v-chemlcal extmguishei is one of the most veisatile units available It extinguishes bv mteiiupting the chemical flame chain leaction (see ex planation earliei m this chaptei) It is not to lie confused with diy powdei extmguisheis discussed m the next section Foul tspes of base agents aie used sodium bicai bonate, potassium bicatbonate, potas sium chloude and ammonium phosphate (multipurpose) When rechaigmg, it is lmpoitant to use onlv the di\' chemical agent and " No longer maiiufactuied 0 Only available as I8-oz disposable unit