To: See Distribution
From:
H. W. Braun
Date:
July, 5, 1988
Subject: Corporate Technical Council Meeting
MEMO
As a result of our Corporate Technical Council Meeting, I am taking the liberty to present an area of interest to us to the attendees I believe may have comparable interest. I've attached some of the results of our investigation, and if you have any information which might help us in our material application search, I would like to receive it.
It was, for me, a worthwhile experience, and getting to know people in our other Divisions is very helpful.
jUsi-ll Henry /. Braun Condtyiser Engineering Manager
HWB/ms
Attachment: Non Asbestos Gasket Material
Distribution:
E. A. Bulanowski R S A.P.D. S Turbine Div.
L. Fisher
- Deltex
A. Gillette
- Enterprise
H. Branch
- Gems
J. Croto
- Boston Gear
J. Brennan
- IMO Pump
C. Mathews
- Enterprise
C. Cannon
- Wiggins
TX0357
IMO DeU'l Condenser Division From i-trert Floifiitf. .NJ "Sols o09-)y9-Jl'U0
NON ASBESTOS GASKET USE
Information exchange desired. Condenser Division, in accordance with invoked Military Specification and prior general practice, had used compressed asbestos sheet gaskets generally 1/32", 1/16" or 1/8" thick.
Although asbestos gasket material completely contains the asbestos fibers, the increasing awareness of customers and the general population of a possible health hazard led us to eliminate the use of. asbestos gasket material on commercial applications. On these applications we generated the attached Engineering Memo #55.
We have also generated a number of requests to the Navy requesting them to generate an alternate material specification to the HH-P-46E Specification which was invoked in our product specifications.
We have been made aware that the Navy has issued Mil-6-24696, and several suppliers are attempting to have products qualified. Our correspondence with them is attached for your reference.
ICondenser Engineering Manager
HWB/ms
TX0358
ENGINEERING MEMO E-55 October 1, 1985
GASKET MATERIALS AND DRAWINGS
Compressed asbestos gasket material is difficult to obtain commercially (and is becoming more so) since just about all sources (at lest in the U.S.A.jhave curtailed or discontinued its manufacture. Several excellent substitutes for the sheet asbestos gasket material have been developed and are available commercially. Some of the acceptable substitutes meeting ASTM F-1C4 are:
1. Garlock - Blue-Gard 2. Anchor Packing - Style 443A 3. Richard Klinger Inc. - Klingersil C-4400
These materials are rated for 750 degrees F and pressures to 1450 psi. They are to be used for all applications falling within this operating range for which asbestos fiber sheet has been previously used; principally for the tube sheet-shell gasket. They are, effective immediately, our standard gasket material for this service.
Customer's specifications requiring asbestos gaskets are to be questioned (by project engineer), making specific efforts to substitute these materials (where possible).
Orawings for gaskets made in "more than one piece" are to show location and type of splices; they (the gasket drawings) will contain cutting sketches showing the "nesting" of the various gasket pieces on the sheet gasket material. The available sizes of gasket material Is to be determined at the time the gasket drawings are prepared; the sizes and quantities needed for the job are to be order via bill of material (as opposed to use of stocked material as is the present practice).
P'oject Engineers are responsible for the implementation of these instructions.
TX0359
Engineering Supervisor
MJl:bf
c.c.:
Drafting Department Engineering Department
J. E. Bricker R. G. Silver
Blue-Gaud
COMPRESSED NON-ASBESTOS GASKETS FROM GARLOCK.
GARLOCK developed BLUE-GARD gaskets to seal as effectively as asbestos in most applications.
ASTM TEST METHOD
F 37
F 36 F 36 F 146
-
PHYSICAL PROPERTY
Scalability Maximum Milliliter. Hour Leakage
Recovery Minimum Percent
Compressibility Percent Range
Oil Resistance after S Hour Immersions ASTM *3 Oil @ -300*F Thickness Increase Range Maximum Tensile Loss
ASTM Fuel B @ -70-S5*F Thickness Increase Range Maximum Weight Increase
Flexibility Bend ISO* around rod with diameter 12x thicker than sheet
TYPICAL DATA
.6 40 7-17
0-13% otA
0-15% 20"i
No cracking
Density Grams. Cm1 (Pounds/Ft.`1
1.60 (1001
OTHER DATA _____________
High Temperature Limit -171'C l*T00*F) ** Maximum Prtaaure < P S.1.1 x Temperature t*F) 700.000" Fluid Resistance From pH of I through It
** This is a general guide and should not bo the sole means of selecting or rejecting this material.
* BLUE-GARD gaskets are avaiiablt in thicknesses of 1/32" thru 1/8".
BLUE-GARD non-asbestos material is made by the traditional sheeter method that has proven itself since 1S96.
BLUE-GARD gaskets meet most of the properties of A STM F 104 for compressed asbestos material.
BLUE-GARD gaskets eliminate the problem of meeting OSHA and EPA asbestos standards.
BLUE-GARD gaskets are comparably priced with asbestos when you figure in the costs of compliance with current regulations.
With testsindicatingGARLOCK BLUE-GARD gaskets serve reliably in most applications, you can expect the exceptional level of performance for w hich the G ARLOC K name has always been known.
MATERIAL
RATING
ACIDS Weak Strong
S ___ NR
ALKALIES Weak Strong
S ___ NR______
GASES
Air. Nitrogen. Carbon
Dioxide and other inert gases .
S
Chlorine. Bromine
'S
Oxygen. Fluorine
;__ ___ NR______
PETROLEUM OILS'"
Paraffinic Aromatic
"
S ___ ______
PHOSPHATE ESTER FLUIDS
NR
REFRIGERANTS (Freon, etc.)
?
SOLVENTS
Alcohols Aliphatic Hydrocarbons
(Heptane. Gasoline) Aromatic Hydrocarbons
1 Benzene. Toluene, etc.) Chlorinated Esters Ketones
iS S
F J
F
NR _ _NR_____
STEAM _____________ ___________
S
WATER St SALT SOLUTIONS RATINGS* '
___ S___
S Satisfactory F Fair NR Not Recommended
mttmm
ma n
far
r--*/****
'*#*
.u.'^'ipeftAw far * ktrk
<e*W
'*+*1 Prep#**eeAef/f* X*
pen, f.rr
0 if^ef i Ihvsv.
TX036O
<;a*UCK * trtiHtPH
pAeb>*n.
i. fkUU utlwr DfMticU *( ' sKLlH- fc
0*>rwlH IMI.UAKLW.'K Inc. All K'l ***"'!
Colt Industries
Mechanical Packing Olvleion Industrial Gasket
i6660feonSl'Mt. Plimyft NwVor '*522 JiS/SSt-AJi t CsnocaoiCsnsosua..Toroio.0"t*/`OM8Z2HS * i S. 25J-91' *
..Xl/JLlOCIv L>1.L> i " v-;'!'vi: o-Oi r i !
^ - ,'/l i i>
blue-gaRD Gasku Hotneot***
) ' ` .. ; -. \ c\:\l : . ' t . j-.-.i \ ' 1
New BLUE-GaRD asbestos-free formula* obsoletes standard compressed gaskets!
rxo36i
GARLOCK BLUE-GARD gaskets ire cut from tough gasketing material manufactured and formulated without asbestos. They're easier to handle on the production line, add a new element of * product reliability, and provide designers and equipment manufacturers additional sales potential. Their fiber content is acrylic, bound by nitrile. More than two years in development BLUE-GARD material now stands alone as a proven replacement for standard compressed sheet gaskets.
BLUE-GARD gaskets can be safely installed in most static sealing applications. They have wide areas of use in manufacturing and processing, off-highway transportation, compressors, small engine applications, and many other products.
BLUE-GARD gaskets are excellent for severe service involving higher pressures and temperatures.
They are especially useful where heavy flanges and high bolt loads are commonly found, such as in
steam lines, engine cylinder heads, compressors, and refrigeration equipment BLUE-GARD
gasket characteristics have been successfully tested to fluid resistance in pH range 1-11. and
temperature resistance to *.'tTI*C
See reverse side for specifications.
O
Compressed Non-Asbestos Gasket Sheet
KLINGERSIL C-4400
High quality NON-ASBESTOS material composed ol fibres with highest chemical stabili ty and heat resistance. Nitrile rubber bonded. Outstanding creep resistance at high temperatures and high loads provides maximum safety, high torque retention and excelent sealing characteristics.
Technical Data
Ail data are typical values and refer to a sheet thickness of 1.6 mm (1 /16 ). UNLESS OTHERWISE NOTED.
MAX. OPERATING Temperature CONDITIONS1" Pressure
COMPRESSIBILITY ASTM F36A
RECOVERY
ASTM F36A
HOT COMPRESSION TEST KLINGER Thickness decrease 23*C(73*F) . Thickness decrease 300 *C (572*F)
TENSILE STRENGTH ASTM Pi 52 across gram
CHANGE IN TENSILE STRENGTH ASTM Fi 52 after immersion m ASTM-Oil 3. 5h 150*C (300*F)
WEIGHT INCREASE ASTM Ft 46 after immersion in Fuel B 5h 23 *C (73* F)
THICKNESS INCREASE ASTM Ft 46 after immersion m ASTM Oil 1 5h 150*C (300"F) ASTM Oil 3 5h 150*C (300'F) ASTM Fuel A 5h 23*C (73*F) ASTM Fuel 8 5h 23*C(73'F)
SEALABILITY ASTM F37 (0. 8mm material) (1 /32)
SPECIFIC GRAVITY
STANDARD SHEET THICKNESS
SHEET SIZES
400* C <7S0*F) 100 bar (1450 osi)
7VI7S min. 50t
lOS'3' 8s01
KLINGER The world leader m "compressed'' type gasket material introduces:
tri The first of a family of asbestos free compressed sheets.
1 SN/mmr(2200 0t>)
ASTM F104 Standard Classification/
1 Non Metallic Gasket Materials
ASTM Ft 04-Class P-1141-A refers spe-
cifically to compressed asbestos materi
al. KLINGERSIL C-4400 fully means the
-25^
physical properties of P-i 141 -A.
max. 15b
0-5"b 0-5b 0-5b 0-5t>
.6 ML/hour
t .5
1/64-1/32-1/16 3/32-1/8
60x45-60x60-60x90 60x120-60x180
CHLORIOE CONTENTKUNGERSIL C-4400 has a very low chloride content (below 100 ppm) and has good anti-stick properties. This pre vents flange corrosion and considerably reduces maintenance time.
HOT COMPRESSION TEST The quality of a compressed gasket ma terial becomes critical when it has to withstand high pressures at elevated ternperature. Below are pictures of Klingersil C-4400 and a competitive non abestos sheet after testing under a load of 3550 psi and 572*F and also at 750*F. The C4400 has been altered only slightly, while the competitive material is crushed at 572*F and destroyed at 750*F.
Suitable For Use With.
Gases
Water
Steam
Inorganic salt solutions
Organic Acids
Alkalis
Aliphatic and Aromatic hydro carbons
' Aliphatic alcohols. esters and ketones
Oils and greases
Heat trans fer Oils
Refngerants
(t) (2) See roles on bacH-page (3) At 25 N/mm 300` C
i
\, STANDARDIZATION DOCUMENT IMrKUvcmtro mury*al |__________ No. 22.R2ss
INSTRUCTIONS: The purpose of this form l to solicit beneficial comments which will help schleve procure- ' oient of suitable products st reasonable cost and minimum delay, or will otherwise enhance use of the document DoO contractors, (ovemment activities, or manufacturers/ vendors who arc prospective suppliers of the product re invited to submit comments to the (ovemment. Fold on lines on reverse side, staple fn comer, and send to preparinc activity. Comments submitted on this form do not constitute or imply authorisation to waive any portion of the referenced document(s) or to amend contractual requirements. Attach any pertinent data which may be rf use in improvinc this document. If there are additional papers, attach to form and place both in an
envelope addressed to preparinc activity.
DOCUMENT lOENTIflER ANO TITLE
MIL-C-15430J and MII-E-15465G
NAME Of ORGANIZATION ANO address
Transamerica Oelaval Inc. Condenser Division Front Street Florence, NJ 08518
CONTRACT NUMBER
material procureo unoer a 1 1 OIRECT GOVERNMENT CONTRACT ` SUiCONTRAC'
t. HAS ANY PART OP THE OOCUMENT CHEATED PROBLEMS OR REQUIRED INTERPRETATION IN PROCUREMENT USET A. CIVC paragraph numgcr ano wording.
MIL-C-15430J Para 2.1. Tables I & II. Para 3.2.16.3 and MIL-E-15465G Para 2.1, Tables IV, V & VI, Para 3.5.2.S.1.1.1.
O. RECOMMENDATIONS PON CORRECTING ThC DEFICIENCIES
See Attached Sheet 2
Z. COMMENTS ON ANY OOCUMENT REOUIREMSMT CONSIDERED TOO RlGIO
3. IS THE OOCUMENT RESTRICTIVE?
1 1 YES
1 1 NO (it
In Mill
TX0363
. REMARKS
We would be pleased to work with you in developing a way to handle and minimize cost to Navy and ourselves.
SUBMITTED BY fPrlni*4 at fyped name and AMrita - Optional)
Henry W. Braun, Engineering Manager
Transamerica Delaval Inc. Condenser Division Florence, NJ 08518
DD,'"",1426
REPLACES COITION OR I JAN
TELEPHONE NO.
(609) 499-3000 Ext. 234
OATE
V April 17. 1985
WHICH mat SC UfCD
t/H 01Ot'OIA1102
Transamerica Delaval Condenser Division
Front Street Florence, NJ 08518
Inc.
April 17, 1985 00 Form 1426
MIL-C-15430J & MIL-E-15465G
Sheet 2
l.B. RECOMMENDATIONS FOR CORRECTING THE DEFICIENCIES
Above paragraphs of subject specifications contain asbestos material. 8ecause of the defined health hazards associated with asbestos we are receiving letters from manufacturers of the sheet gasket and spiral wound gasket stating that shortly they will be discontinuing the use of asbestos as a gasket material. If the Navy has adopted any alternate non asbestos gasket material and has generated the associated specifications we would like to have them identified. We also believe, an amendment or revised specification should be issued to provide authority to use an alternate material for application in the identified paragraphs; i.e.:
(1) MIL-A-17472 - Replaced byMV-P.46 for sheet compressed asbestos gaskets
(2) MIL-G-21032E. Spiral Wound Metallic Asbestos (not listed in specification but used for steam piping joints)
(3) MIL-P-2863, Packing, Condenser
(4) MIL-P-17303C, Asbestos Jacketed Packing
Specifications should be changed to reflect new non asbestos gasket specifications. There are currently non asbestos substitutes; however, in lieu of requests for acceptance on each contract we are involved in, we would like specification alternatives that would permit substitution without extensive administrative effort. We believe there must be comparable requests for many other types of equipment and piping applications used for Navy and 000 contracts.
For your reference we have attached letters we have received. We are asking our vendors to supply alternates but we would like to use the specification that the Navy has selected.
Enclosure: A. Gallagher Fluid Seals letter dtd April 11, 1985 B. John Crane International Sealing Systems letter dtd March 6, 1985
BCC:
H. W. Braun J. Gansky r. J. Hamm F. J. Smollon, Landover Office File MIL-C-15430J File MIL-E-154656 File MIL-A-17472 File MIL-G-21032E File MIL-P-2863 File MIL-P-17303
TX0364
J
;<Hm-STD-481A ' * 18 October 1972
icquist roa ocviatiw/mivj* isit iL'STo-*t m tii ro* itsrncvoHS)
9ATC M(#tl(0
June 28. 1985
><OCU*IM tCIIVITY MO.
i. oisiio nmk imp tpeacii
CiraonndseanmseerricDaivOiseiolanval Inc.
Fron^Streei^^J^rencg^NJOgJlS
IQ MVAt ION
i v(i
* mimo "Ajoa CaiTic
4. QCSICNATiQn fQB QgviAT IOM/VAIv*
. MOOtL/tC 8. N#A. COOC r. v. OCStG. 4.
D SA619
511875-001
i. S^ccinctTioss *frccTto-TCST oln
5. MU U*C AffCCTtd
fUNC.
tionh
lAALO.
LJcatcd i
. 0t*ca STSTCNS/CONfiGUa ation itoiS ArrccTco
I--I 00.
LJuct
Quj
Qno
oaaiNCs arrccTcg
COGt *ce./ooe. mo.
SC* -FA. COOC
"UMca
1 Cv.
>*Oa. no.
e. SYSTtM 1
4. : to*
___ 5A619 MIL-E-15465G______
. Tt$T H*N 1
1
]
9. TI7LC Of 3CVlAriC*>/A>v(
1 1
pO. COM!CT MO. a LIM( I T
GASKET MATERIAL SUBSTITUTION FOR ASBESTOS
C8-03236-011-00100
n. coMnouitT-ON i;t Micsci.:ut AIR EJECTOR ASSEMBLIES
3' KMCT
& 00?d!
I. co mo. (I. OC'CCt N la. ocrccT classification
^
jT^MIMOl ^^M.JOI 1 (cilTICM.
it. ftjc # mit oa GASKETS
iiueKf imcTu
. #*t me. *a net acti*. 1. LOT NO. IB. QTV
if. accuaaiMC oivi ation/sai *ca
O'** -
NONE 21. ixeer OM iMTijxrto LiO.it.c suaaoat. ,MTirct. nc.
NONE
NONE
it. ocscaiaTiON at otpnoM.ivca Suppliers of asbestos gasketing (because of health hazard) we find are dropping the
manufacture of material and our sources are being reduced to point where we will be unable to obtain it. Air ejector specification MIL-E-15465G defines MIL-A-17472
which has been superseded by HH-P-46. Subtantiating severity of problem we attach
vendor correspondence we have received. Reference Walter B. Gallaher Company letter dated April 11, 1985 and J. Crane's letters dated March 6, 1985 and May 23,
1985. We have tried further to locate alternate sources but have not been successful.
Specification changes have also been requested of NAVSEA via Standardization Document
Improvement Proposal Form DD 1426 dtd April 17, 1985.
X. Mtto ro OlvltTiOM/mvCI We would .like your approval to ase either the J. Crane Style 2160 material defined in their May 23, 1985 letter or Blue-Gard (data bulletin attached) as an alternate for the compressed asbestos/military specification we currently are using. Should shipyard have a defined alternate they preferably would like to use, we would like the product details and specifications so we could procure and use as an alternate.
ENCLOSURES: 1. BLUE-GARO - Colt Industries Bulletin GSK 320
2. Standardization Document Improvement Proposal to NAVSEA
dtd 4/17/85 with attached vendor letters
3. John Crane letter dated May 23, 1985
TX0365
21. 'OOUCTIO. ("CCIVlTT IT u*l*h NhMMI 511875 thru 511881
nn itr.iAQi
Figure - 2 Page 8
@Colt Industries
June 15, 1988
/ Oarlock Inc Mechanical Packing oivlaion 1666 Oivision Street Palmyra, New York U522-83S5 315/597-4611
Tele* No.: 249564
Panel** No.: 315/597-5556 or
315/597-3216
Mr. T. P. Dooley, Imo Delaval Inc. Delaval Condenser Division Front Street Florence, NJ 08518
JUN20ige$
Dear Mr. Dooley:
Thank you for your letter of 6-10-88 concerning gasketing recommendations for MIL-G-24696.
We believe that Garlock Styles 3200/3400 and 3000 will meet all of the requirements of the proposed specification and as soon'as we have completed our testing, we shall advise you of our findings.
If you should have any further questions, please contact me.
Very truly yours,
GARLOCK INC
Agnes Potepajf Manager, Sheet & Gasket Engineering
.....................
A?:jmh
cc: RL Whittaker
TX0366
ATTN: T. P._ Dooley - Senior 3-^er
err -
5.U3J2CT: Son-Asbestos Gasketing Material
^ . :* ' >". Mr..RSOoley r
I have as yet not seen any information fron NAVSZA as to specific___ ' approval of our or any other non-asbestos gasketing material. ^
While ve have been vorking vith Mil specs MH-C-XX1T7 and MIL-G-XX272, and have submitted samples and apparently passed all of the prelim inary tests, as far as I can presently determine, the tests have been stopped or are in limbo, but I'm not quite sure.
_. I've asked our nan on the East coast vho is in touch'vith 3AVSE3C disc *and others-involved"in"tHfS"'ls' to the-Present statTu,' as "Trve gat a large file on these particular items, but no ansvers -
Last veek though, I vas in touch vith 3SV Laboratories vhcTare 'doing --yavy-testingyand-pgTBapy-pTggrg'ST~ vtjjL jjaofl beside/
If I find out** anything further, from our'East coastTcdhtacty l vill get hack to yott.-r --..................- -................... -- rrr -------
-.i-Atwr/i - -- -t.~ -- -5 **t- - -- T.--Str.- --
Sincerely,J0H3 CRAJTE ISC
jeorge HnecXillop Product Manager Packing Divisica
GS-K7l=pT'
cc: - Frank Crosetti - Fairfield Dick Boardman - Washington, DC
TX0367
i
@Colt Industries
April 25, 1988
Garlock Inc
Mechanical Packing Division 1648 Division Straot
Pslmyra. Naw Vorli 1SS22-63SS 315/597-4811 Talas No.: 249584 Panalas No.: 315/597-5554 or
315/597-3218
IMO Delaval Inc. Delaval Condenser Div. Front St. Florence, NJ 08518
Attn: Mr. T. P. Dooley Senior Buyer
Dear Mr. Dooley:
Received f p12 7 iS88 CONDENSES ENG'G.
This letter refers to your letter of 4-5-88 and our telephone conversation of 4-13-88 concerning a non-asbestos gasketing specification for HH-P-46E.
We have been advised that the new specification is in the process of being printed and the number assigned is MIL G-24696 (formerly MIL-G-XX177(SH).
We have already submitted a number of our products for inclusion in the QPL listing. Hopefully, this information will be available in several months time and we shall keep you posted on developments.
Should you require any additional information, please contact me.
Very truly yours,
A/ Potepan Manager, Sheet & Gasket Engineering
AP:jmh
TX0368
RECEIVED
APR 2 ' iSBb
Miif-WM SiPARIVOI