Document GzogpnN4e7yar5JbbB4gwVb2V

I mo Dla\ Detail Front Stri Florence. 609-499' To: See Distribution From: H. W. Braun Date: July, 5, 1988 Subject: Corporate Technical Council Meeting MEMO As a result of our Corporate Technical Council Meeting, I am taking the liberty to present an area of interest to us to the attendees I believe may have comparable interest. I've attached some of the results of our investigation, and if you have any information which might help us in our material application search, I would like to receive it. It was, for me, a worthwhile experience, and getting to know people in our other Divisions is very helpful. jUsi-ll Henry /. Braun Condtyiser Engineering Manager HWB/ms Attachment: Non Asbestos Gasket Material Distribution: E. A. Bulanowski R S A.P.D. S Turbine Div. L. Fisher - Deltex A. Gillette - Enterprise H. Branch - Gems J. Croto - Boston Gear J. Brennan - IMO Pump C. Mathews - Enterprise C. Cannon - Wiggins TX0357 IMO DeU'l Condenser Division From i-trert Floifiitf. .NJ "Sols o09-)y9-Jl'U0 NON ASBESTOS GASKET USE Information exchange desired. Condenser Division, in accordance with invoked Military Specification and prior general practice, had used compressed asbestos sheet gaskets generally 1/32", 1/16" or 1/8" thick. Although asbestos gasket material completely contains the asbestos fibers, the increasing awareness of customers and the general population of a possible health hazard led us to eliminate the use of. asbestos gasket material on commercial applications. On these applications we generated the attached Engineering Memo #55. We have also generated a number of requests to the Navy requesting them to generate an alternate material specification to the HH-P-46E Specification which was invoked in our product specifications. We have been made aware that the Navy has issued Mil-6-24696, and several suppliers are attempting to have products qualified. Our correspondence with them is attached for your reference. ICondenser Engineering Manager HWB/ms TX0358 ENGINEERING MEMO E-55 October 1, 1985 GASKET MATERIALS AND DRAWINGS Compressed asbestos gasket material is difficult to obtain commercially (and is becoming more so) since just about all sources (at lest in the U.S.A.jhave curtailed or discontinued its manufacture. Several excellent substitutes for the sheet asbestos gasket material have been developed and are available commercially. Some of the acceptable substitutes meeting ASTM F-1C4 are: 1. Garlock - Blue-Gard 2. Anchor Packing - Style 443A 3. Richard Klinger Inc. - Klingersil C-4400 These materials are rated for 750 degrees F and pressures to 1450 psi. They are to be used for all applications falling within this operating range for which asbestos fiber sheet has been previously used; principally for the tube sheet-shell gasket. They are, effective immediately, our standard gasket material for this service. Customer's specifications requiring asbestos gaskets are to be questioned (by project engineer), making specific efforts to substitute these materials (where possible). Orawings for gaskets made in "more than one piece" are to show location and type of splices; they (the gasket drawings) will contain cutting sketches showing the "nesting" of the various gasket pieces on the sheet gasket material. The available sizes of gasket material Is to be determined at the time the gasket drawings are prepared; the sizes and quantities needed for the job are to be order via bill of material (as opposed to use of stocked material as is the present practice). P'oject Engineers are responsible for the implementation of these instructions. TX0359 Engineering Supervisor MJl:bf c.c.: Drafting Department Engineering Department J. E. Bricker R. G. Silver Blue-Gaud COMPRESSED NON-ASBESTOS GASKETS FROM GARLOCK. GARLOCK developed BLUE-GARD gaskets to seal as effectively as asbestos in most applications. ASTM TEST METHOD F 37 F 36 F 36 F 146 - PHYSICAL PROPERTY Scalability Maximum Milliliter. Hour Leakage Recovery Minimum Percent Compressibility Percent Range Oil Resistance after S Hour Immersions ASTM *3 Oil @ -300*F Thickness Increase Range Maximum Tensile Loss ASTM Fuel B @ -70-S5*F Thickness Increase Range Maximum Weight Increase Flexibility Bend ISO* around rod with diameter 12x thicker than sheet TYPICAL DATA .6 40 7-17 0-13% otA 0-15% 20"i No cracking Density Grams. Cm1 (Pounds/Ft.`1 1.60 (1001 OTHER DATA _____________ High Temperature Limit -171'C l*T00*F) ** Maximum Prtaaure < P S.1.1 x Temperature t*F) 700.000" Fluid Resistance From pH of I through It ** This is a general guide and should not bo the sole means of selecting or rejecting this material. * BLUE-GARD gaskets are avaiiablt in thicknesses of 1/32" thru 1/8". BLUE-GARD non-asbestos material is made by the traditional sheeter method that has proven itself since 1S96. BLUE-GARD gaskets meet most of the properties of A STM F 104 for compressed asbestos material. BLUE-GARD gaskets eliminate the problem of meeting OSHA and EPA asbestos standards. BLUE-GARD gaskets are comparably priced with asbestos when you figure in the costs of compliance with current regulations. With testsindicatingGARLOCK BLUE-GARD gaskets serve reliably in most applications, you can expect the exceptional level of performance for w hich the G ARLOC K name has always been known. MATERIAL RATING ACIDS Weak Strong S ___ NR ALKALIES Weak Strong S ___ NR______ GASES Air. Nitrogen. Carbon Dioxide and other inert gases . S Chlorine. Bromine 'S Oxygen. Fluorine ;__ ___ NR______ PETROLEUM OILS'" Paraffinic Aromatic " S ___ ______ PHOSPHATE ESTER FLUIDS NR REFRIGERANTS (Freon, etc.) ? SOLVENTS Alcohols Aliphatic Hydrocarbons (Heptane. Gasoline) Aromatic Hydrocarbons 1 Benzene. Toluene, etc.) Chlorinated Esters Ketones iS S F J F NR _ _NR_____ STEAM _____________ ___________ S WATER St SALT SOLUTIONS RATINGS* ' ___ S___ S Satisfactory F Fair NR Not Recommended mttmm ma n far r--*/**** '*#* .u.'^'ipeftAw far * ktrk <e*W '*+*1 Prep#**eeAef/f* X* pen, f.rr 0 if^ef i Ihvsv. TX036O <;a*UCK * trtiHtPH pAeb>*n. i. fkUU utlwr DfMticU *( ' sKLlH- fc 0*>rwlH IMI.UAKLW.'K Inc. All K'l ***"'! Colt Industries Mechanical Packing Olvleion Industrial Gasket i6660feonSl'Mt. Plimyft NwVor '*522 JiS/SSt-AJi t CsnocaoiCsnsosua..Toroio.0"t*/`OM8Z2HS * i S. 25J-91' * ..Xl/JLlOCIv L>1.L> i " v-;'!'vi: o-Oi r i ! ^ - ,'/l i i> blue-gaRD Gasku Hotneot*** ) ' ` .. ; -. \ c\:\l : . ' t . j-.-.i \ ' 1 New BLUE-GaRD asbestos-free formula* obsoletes standard compressed gaskets! rxo36i GARLOCK BLUE-GARD gaskets ire cut from tough gasketing material manufactured and formulated without asbestos. They're easier to handle on the production line, add a new element of * product reliability, and provide designers and equipment manufacturers additional sales potential. Their fiber content is acrylic, bound by nitrile. More than two years in development BLUE-GARD material now stands alone as a proven replacement for standard compressed sheet gaskets. BLUE-GARD gaskets can be safely installed in most static sealing applications. They have wide areas of use in manufacturing and processing, off-highway transportation, compressors, small engine applications, and many other products. BLUE-GARD gaskets are excellent for severe service involving higher pressures and temperatures. They are especially useful where heavy flanges and high bolt loads are commonly found, such as in steam lines, engine cylinder heads, compressors, and refrigeration equipment BLUE-GARD gasket characteristics have been successfully tested to fluid resistance in pH range 1-11. and temperature resistance to *.'tTI*C See reverse side for specifications. O Compressed Non-Asbestos Gasket Sheet KLINGERSIL C-4400 High quality NON-ASBESTOS material composed ol fibres with highest chemical stabili ty and heat resistance. Nitrile rubber bonded. Outstanding creep resistance at high temperatures and high loads provides maximum safety, high torque retention and excelent sealing characteristics. Technical Data Ail data are typical values and refer to a sheet thickness of 1.6 mm (1 /16 ). UNLESS OTHERWISE NOTED. MAX. OPERATING Temperature CONDITIONS1" Pressure COMPRESSIBILITY ASTM F36A RECOVERY ASTM F36A HOT COMPRESSION TEST KLINGER Thickness decrease 23*C(73*F) . Thickness decrease 300 *C (572*F) TENSILE STRENGTH ASTM Pi 52 across gram CHANGE IN TENSILE STRENGTH ASTM Fi 52 after immersion m ASTM-Oil 3. 5h 150*C (300*F) WEIGHT INCREASE ASTM Ft 46 after immersion in Fuel B 5h 23 *C (73* F) THICKNESS INCREASE ASTM Ft 46 after immersion m ASTM Oil 1 5h 150*C (300"F) ASTM Oil 3 5h 150*C (300'F) ASTM Fuel A 5h 23*C (73*F) ASTM Fuel 8 5h 23*C(73'F) SEALABILITY ASTM F37 (0. 8mm material) (1 /32) SPECIFIC GRAVITY STANDARD SHEET THICKNESS SHEET SIZES 400* C <7S0*F) 100 bar (1450 osi) 7VI7S min. 50t lOS'3' 8s01 KLINGER The world leader m "compressed'' type gasket material introduces: tri The first of a family of asbestos free compressed sheets. 1 SN/mmr(2200 0t>) ASTM F104 Standard Classification/ 1 Non Metallic Gasket Materials ASTM Ft 04-Class P-1141-A refers spe- cifically to compressed asbestos materi al. KLINGERSIL C-4400 fully means the -25^ physical properties of P-i 141 -A. max. 15b 0-5"b 0-5b 0-5b 0-5t> .6 ML/hour t .5 1/64-1/32-1/16 3/32-1/8 60x45-60x60-60x90 60x120-60x180 CHLORIOE CONTENTKUNGERSIL C-4400 has a very low chloride content (below 100 ppm) and has good anti-stick properties. This pre vents flange corrosion and considerably reduces maintenance time. HOT COMPRESSION TEST The quality of a compressed gasket ma terial becomes critical when it has to withstand high pressures at elevated ternperature. Below are pictures of Klingersil C-4400 and a competitive non abestos sheet after testing under a load of 3550 psi and 572*F and also at 750*F. The C4400 has been altered only slightly, while the competitive material is crushed at 572*F and destroyed at 750*F. Suitable For Use With. Gases Water Steam Inorganic salt solutions Organic Acids Alkalis Aliphatic and Aromatic hydro carbons ' Aliphatic alcohols. esters and ketones Oils and greases Heat trans fer Oils Refngerants (t) (2) See roles on bacH-page (3) At 25 N/mm 300` C i \, STANDARDIZATION DOCUMENT IMrKUvcmtro mury*al |__________ No. 22.R2ss INSTRUCTIONS: The purpose of this form l to solicit beneficial comments which will help schleve procure- ' oient of suitable products st reasonable cost and minimum delay, or will otherwise enhance use of the document DoO contractors, (ovemment activities, or manufacturers/ vendors who arc prospective suppliers of the product re invited to submit comments to the (ovemment. Fold on lines on reverse side, staple fn comer, and send to preparinc activity. Comments submitted on this form do not constitute or imply authorisation to waive any portion of the referenced document(s) or to amend contractual requirements. Attach any pertinent data which may be rf use in improvinc this document. If there are additional papers, attach to form and place both in an envelope addressed to preparinc activity. DOCUMENT lOENTIflER ANO TITLE MIL-C-15430J and MII-E-15465G NAME Of ORGANIZATION ANO address Transamerica Oelaval Inc. Condenser Division Front Street Florence, NJ 08518 CONTRACT NUMBER material procureo unoer a 1 1 OIRECT GOVERNMENT CONTRACT ` SUiCONTRAC' t. HAS ANY PART OP THE OOCUMENT CHEATED PROBLEMS OR REQUIRED INTERPRETATION IN PROCUREMENT USET A. CIVC paragraph numgcr ano wording. MIL-C-15430J Para 2.1. Tables I & II. Para 3.2.16.3 and MIL-E-15465G Para 2.1, Tables IV, V & VI, Para 3.5.2.S.1.1.1. O. RECOMMENDATIONS PON CORRECTING ThC DEFICIENCIES See Attached Sheet 2 Z. COMMENTS ON ANY OOCUMENT REOUIREMSMT CONSIDERED TOO RlGIO 3. IS THE OOCUMENT RESTRICTIVE? 1 1 YES 1 1 NO (it In Mill TX0363 . REMARKS We would be pleased to work with you in developing a way to handle and minimize cost to Navy and ourselves. SUBMITTED BY fPrlni*4 at fyped name and AMrita - Optional) Henry W. Braun, Engineering Manager Transamerica Delaval Inc. Condenser Division Florence, NJ 08518 DD,'"",1426 REPLACES COITION OR I JAN TELEPHONE NO. (609) 499-3000 Ext. 234 OATE V April 17. 1985 WHICH mat SC UfCD t/H 01Ot'OIA1102 Transamerica Delaval Condenser Division Front Street Florence, NJ 08518 Inc. April 17, 1985 00 Form 1426 MIL-C-15430J & MIL-E-15465G Sheet 2 l.B. RECOMMENDATIONS FOR CORRECTING THE DEFICIENCIES Above paragraphs of subject specifications contain asbestos material. 8ecause of the defined health hazards associated with asbestos we are receiving letters from manufacturers of the sheet gasket and spiral wound gasket stating that shortly they will be discontinuing the use of asbestos as a gasket material. If the Navy has adopted any alternate non asbestos gasket material and has generated the associated specifications we would like to have them identified. We also believe, an amendment or revised specification should be issued to provide authority to use an alternate material for application in the identified paragraphs; i.e.: (1) MIL-A-17472 - Replaced byMV-P.46 for sheet compressed asbestos gaskets (2) MIL-G-21032E. Spiral Wound Metallic Asbestos (not listed in specification but used for steam piping joints) (3) MIL-P-2863, Packing, Condenser (4) MIL-P-17303C, Asbestos Jacketed Packing Specifications should be changed to reflect new non asbestos gasket specifications. There are currently non asbestos substitutes; however, in lieu of requests for acceptance on each contract we are involved in, we would like specification alternatives that would permit substitution without extensive administrative effort. We believe there must be comparable requests for many other types of equipment and piping applications used for Navy and 000 contracts. For your reference we have attached letters we have received. We are asking our vendors to supply alternates but we would like to use the specification that the Navy has selected. Enclosure: A. Gallagher Fluid Seals letter dtd April 11, 1985 B. John Crane International Sealing Systems letter dtd March 6, 1985 BCC: H. W. Braun J. Gansky r. J. Hamm F. J. Smollon, Landover Office File MIL-C-15430J File MIL-E-154656 File MIL-A-17472 File MIL-G-21032E File MIL-P-2863 File MIL-P-17303 TX0364 J ;<Hm-STD-481A ' * 18 October 1972 icquist roa ocviatiw/mivj* isit iL'STo-*t m tii ro* itsrncvoHS) 9ATC M(#tl(0 June 28. 1985 ><OCU*IM tCIIVITY MO. i. oisiio nmk imp tpeacii CiraonndseanmseerricDaivOiseiolanval Inc. Fron^Streei^^J^rencg^NJOgJlS IQ MVAt ION i v(i * mimo "Ajoa CaiTic 4. QCSICNATiQn fQB QgviAT IOM/VAIv* . MOOtL/tC 8. N#A. COOC r. v. OCStG. 4. D SA619 511875-001 i. S^ccinctTioss *frccTto-TCST oln 5. MU U*C AffCCTtd fUNC. tionh lAALO. LJcatcd i . 0t*ca STSTCNS/CONfiGUa ation itoiS ArrccTco I--I 00. LJuct Quj Qno oaaiNCs arrccTcg COGt *ce./ooe. mo. SC* -FA. COOC "UMca 1 Cv. >*Oa. no. e. SYSTtM 1 4. : to* ___ 5A619 MIL-E-15465G______ . Tt$T H*N 1 1 ] 9. TI7LC Of 3CVlAriC*>/A>v( 1 1 pO. COM!CT MO. a LIM( I T GASKET MATERIAL SUBSTITUTION FOR ASBESTOS C8-03236-011-00100 n. coMnouitT-ON i;t Micsci.:ut AIR EJECTOR ASSEMBLIES 3' KMCT & 00?d! I. co mo. (I. OC'CCt N la. ocrccT classification ^ jT^MIMOl ^^M.JOI 1 (cilTICM. it. ftjc # mit oa GASKETS iiueKf imcTu . #*t me. *a net acti*. 1. LOT NO. IB. QTV if. accuaaiMC oivi ation/sai *ca O'** - NONE 21. ixeer OM iMTijxrto LiO.it.c suaaoat. ,MTirct. nc. NONE NONE it. ocscaiaTiON at otpnoM.ivca Suppliers of asbestos gasketing (because of health hazard) we find are dropping the manufacture of material and our sources are being reduced to point where we will be unable to obtain it. Air ejector specification MIL-E-15465G defines MIL-A-17472 which has been superseded by HH-P-46. Subtantiating severity of problem we attach vendor correspondence we have received. Reference Walter B. Gallaher Company letter dated April 11, 1985 and J. Crane's letters dated March 6, 1985 and May 23, 1985. We have tried further to locate alternate sources but have not been successful. Specification changes have also been requested of NAVSEA via Standardization Document Improvement Proposal Form DD 1426 dtd April 17, 1985. X. Mtto ro OlvltTiOM/mvCI We would .like your approval to ase either the J. Crane Style 2160 material defined in their May 23, 1985 letter or Blue-Gard (data bulletin attached) as an alternate for the compressed asbestos/military specification we currently are using. Should shipyard have a defined alternate they preferably would like to use, we would like the product details and specifications so we could procure and use as an alternate. ENCLOSURES: 1. BLUE-GARO - Colt Industries Bulletin GSK 320 2. Standardization Document Improvement Proposal to NAVSEA dtd 4/17/85 with attached vendor letters 3. John Crane letter dated May 23, 1985 TX0365 21. 'OOUCTIO. ("CCIVlTT IT u*l*h NhMMI 511875 thru 511881 nn itr.iAQi Figure - 2 Page 8 @Colt Industries June 15, 1988 / Oarlock Inc Mechanical Packing oivlaion 1666 Oivision Street Palmyra, New York U522-83S5 315/597-4611 Tele* No.: 249564 Panel** No.: 315/597-5556 or 315/597-3216 Mr. T. P. Dooley, Imo Delaval Inc. Delaval Condenser Division Front Street Florence, NJ 08518 JUN20ige$ Dear Mr. Dooley: Thank you for your letter of 6-10-88 concerning gasketing recommendations for MIL-G-24696. We believe that Garlock Styles 3200/3400 and 3000 will meet all of the requirements of the proposed specification and as soon'as we have completed our testing, we shall advise you of our findings. If you should have any further questions, please contact me. Very truly yours, GARLOCK INC Agnes Potepajf Manager, Sheet & Gasket Engineering ..................... A?:jmh cc: RL Whittaker TX0366 ATTN: T. P._ Dooley - Senior 3-^er err - 5.U3J2CT: Son-Asbestos Gasketing Material ^ . :* ' >". Mr..RSOoley r I have as yet not seen any information fron NAVSZA as to specific___ ' approval of our or any other non-asbestos gasketing material. ^ While ve have been vorking vith Mil specs MH-C-XX1T7 and MIL-G-XX272, and have submitted samples and apparently passed all of the prelim inary tests, as far as I can presently determine, the tests have been stopped or are in limbo, but I'm not quite sure. _. I've asked our nan on the East coast vho is in touch'vith 3AVSE3C disc *and others-involved"in"tHfS"'ls' to the-Present statTu,' as "Trve gat a large file on these particular items, but no ansvers - Last veek though, I vas in touch vith 3SV Laboratories vhcTare 'doing --yavy-testingyand-pgTBapy-pTggrg'ST~ vtjjL jjaofl beside/ If I find out** anything further, from our'East coastTcdhtacty l vill get hack to yott.-r --..................- -................... -- rrr ------- -.i-Atwr/i - -- -t.~ -- -5 **t- - -- T.--Str.- -- Sincerely,J0H3 CRAJTE ISC jeorge HnecXillop Product Manager Packing Divisica GS-K7l=pT' cc: - Frank Crosetti - Fairfield Dick Boardman - Washington, DC TX0367 i @Colt Industries April 25, 1988 Garlock Inc Mechanical Packing Division 1648 Division Straot Pslmyra. Naw Vorli 1SS22-63SS 315/597-4811 Talas No.: 249584 Panalas No.: 315/597-5554 or 315/597-3218 IMO Delaval Inc. Delaval Condenser Div. Front St. Florence, NJ 08518 Attn: Mr. T. P. Dooley Senior Buyer Dear Mr. Dooley: Received f p12 7 iS88 CONDENSES ENG'G. This letter refers to your letter of 4-5-88 and our telephone conversation of 4-13-88 concerning a non-asbestos gasketing specification for HH-P-46E. We have been advised that the new specification is in the process of being printed and the number assigned is MIL G-24696 (formerly MIL-G-XX177(SH). We have already submitted a number of our products for inclusion in the QPL listing. Hopefully, this information will be available in several months time and we shall keep you posted on developments. Should you require any additional information, please contact me. Very truly yours, A/ Potepan Manager, Sheet & Gasket Engineering AP:jmh TX0368 RECEIVED APR 2 ' iSBb Miif-WM SiPARIVOI