DRAFT COMMENTS ON VINYL CHLORIDE NESHAPS PROPOSAL
Enclosed is a sscond draft of Vista's comments on the proposed vinyl chloride NESHAPS. Comments are due to EPA by 3/25 I'd like your comments no later than 3/21 so we have time to discuss and make
modifications.
J. C. Ledvlna
ajq/003
Enclosure
DISTRIBUTION:
Veldon Messick Mike Hayes Eon Bryan Paul Warner John KcCullay Bill McClain
VAB.0001178359
*
February 26, 1985 Central Docket Section (A-130) U. S. Environmental Protection Agency
401 M Street S, W. Washington, DC 20460 Attention Docket Number A-81-21
HA FT
4*
Vista Chemical Company ts taking this opportunity to comment on the 1/9/85 proposed Vinyl Chloride NESHAP's. Vista Chemical owns and operates a vinyl chloride monomer plant and, through its subsidiary Vista Polymers, Inc., two polyvinyl chloride plants. On July 20, 1984 these plants were purchased from Conoco, Inc. which had operated the plants since the Vinyl Chloride NESHAP's was promulgated. Most of the plants1 staffs are former Conoco employees. These comments are thus based on eight years experience under the Vinyl Chloride NESHAP's.
Vista has worked through the Vinyl Institute to assist EPA in this rulemaking. Representatives of Vista have met with EPA over the past two years providing technical assistance and Vista provided comments on the standard at the August 1984 NAPCTAC hearing. In previous meetings and at NAPCTAC we expressed an opinion that the Leak Detection and Elimination (LD&E) provisions of the current NESHAP's is adequate to protect human health and Che environment. Obviously, by the 1/9/85 proposal, EPA Intends to push Subpart V in addition to the existing LD&E program. We believe EPA is overstepping Its authority under the Clean Air Act by requiring compliance with Subpart V. We believe Subpart V is balng arbitrarily imposed on an Industry without any justification. A daaire by the Agency for consistency is not justification for the additional cost and administrative burden of Subpart V.
The standard writers argue thet proving existing LD&E programs equivalent to Subpart V requires little effort. Our experience has been that Regions make very strict comparisons when evaluating equivalencies and that an inordinate number of man-hours Is required to prepare an equivalency request. Vista is skeptical that the Regions will approve effective programs chat are not as administratively tedious as Subpart
V. The only justification for imposing the additional financial and
admlnlstratlva burden of Subpart V Is for a demonstrated health effect. On page 1183 of the preamble, EPA states that the Carcinogen Assessment Group (CAG) did not propose a change In the vinyl chloride unit risk number after reviewing new health studies. The preamble goes on to say that none of these new studies had sufficient exposure information to warrant a refinament in the unit risk factor. It is obvious from the preamble language thet the basic information needed to justify a more burdensome fugitive emission control program is not available. No
health justification exists.
EPA Implies that Subpart V will not have a substantial effect on the VC and PVC plants. They state that this rulemaking is an administrative change leaving che impression that no justification is necessary. This reasoning is seriously flawed. Subpart V is more than an administrative change.
VAB.0001178360
*
One of Vista's PVC plants estimates that it will need to spend $600,000 to comply with the "open-ended valve" provisions of Subpart V, In addition, expenditures will be necessary to comply with the sensor requirements for pumps and compressors. These expenditures will not substantially reduce fugitive emissions since fugitive emissions from pumps, compressors, and open~ended valves are controlled by the existing Leak Detection and Elimination program. Expenditures of thla nature must be justified, EPA has not provided that justification, Vista takaa excaption to the statement on page 1193 of the preamble where EPA states:
"... the proposed administrative revisions do not Increase the coat of compliance with the standard,.
In the same section under Regulatory Flexibility Analysis, EPA states that no small business Is affected by this proposal. A small business is one that has 500 employees or lass. Vista Polymers, Inc. has 300 employees and qualifies as a small business under EPA's definition.
Additionally, on page 1193, EPA states that these revisions will reduce paperwork by 2.8 person-years, We have no accurate data to refute this, but wa are skeptical chat EPA has dona a comprehensive analysis of the effect of Subpart V on paperwork, Not considered is the paperwork Increase imposed on Industry. The VC NESHAP's is already heavily weighted with paperwork. Inclusion of Subpart V will add to that burden.
EPA has taken a reasoned approach to risk assessment In its decision to not regulate processors, landfills, and othar users of vinyl chloride. Although no specifics are presented, this decision had to be based on a judgement that these sources present no significant risk. If EPA bed quantitative data on VC fugitive emissions comparing existing LD&E programs with emission after implementing Subpart V, it would likely show emission changes to be less than could be realized by regulating the above sources. Surely, EPA is not targeting a significant source of vinyl chloride when it goes after fugitives.
The data base for Subpart V has little to do with fugitive emission levels in PVC end VCM plants. The vinyl chloride industry is a low leak Industry. Subpart V and its predecessor, the SOCMX Fugitive NSPS, are based on refinery fugitive data. That data was gatharad after the VC industry had already Implemented Its Leak Detection and Elimination programs. The emission reductions projected for Subpart V are not accurate for the VC Industry.
Use of Subpart V could result in an increase in fugitive emissions from VCM and PVC plants. Under Subpart V, a leak is defined as an instrument reading of 10,000 ppm. This is much higher than Vista's plants use as a definition of a leak. It can be argued that adoption of the Subpart V definition will result in fewer leaks being repaired than under the existing programs.
The VCM/PVC business is not a lucrative one. The VC NESHAP's does its share to erode the industry profitability. Within the domes178361
market this probably can be compensated for. However, the industry Is under pressure from foreign producers. These producers are not subject to NESHAP's.
Vista urges EPA to drop its efforts to incorporate Subpart V into the VC standard. The NESHAP's program is extremely tedious and resource intensive. We know of no other regulatory program that Is as pervasive as the VC NESHAP's. The benefit of such stringent regulation has to be questioned. To add Subpart V absent justification perplexes some of us and Infuriates others.
Although there Is no justification for inclusion of Subpart V in the VC NESHAP's, Vista has reviewed the proposal and has the following specific comments;
Definition of a Leak - Section 61.61(w) Item 2 within the definition "..,(2) indications of liquid
dripping..." should be expanded to read "...(2) Indications of liquid dripping followed by an instrument reading of 10,000 ppm. In pumps and compressors where the seal liquid la at a higher pressure than the process fluid, failure of the inner seal would result in seal fluid entering the process. Drips from the outer seal would not contain VC normally. Checking the drip with an Instrument and repairing If the instrument reads over 10,000 ppm is reasonable.
Item (A) needs to be clarified so there is no misunderstanding that this applies to aealless valves, pumps, and relief valves. We are concerned that an enforcement person in the Region or State would use 500 ppm as the definition of a leak for all equipment.
2. Rupture Disks Under Relief Valves The current NESHAP's requires rupture disks under relief
valves. The proposal should be modified to recognize this as leakless technology. No monitoring of relief valves protected by rupture disks should be required. Subpart V states that RV'a must have a no detectable level. We believe a rupture disk meets this requirement and the regulation should say so.
Leak Detection and Elimination Program 4U We believe these existing programs to be effective, EPA Is
apparently less confident. To reassure the EPA, we suggest that plants be allowed to keep their approved customized programs to control fugitives and not do Subpart V valve monitoring. We propose an annual spot check be performed as written In 61.65(b)(8)(11)(B) This would provide EPA with an indication of an effective program. This concept is suggested in the preamble on page 1191 under the "Leak Detection and Repair Requirements" section.
4. Valve Monitoring - 61.65(b)(8)(li)(E) The preamble states in several places that it is EPA'a Intent
to require a more standardized valve monitoring program and not to change other fugitive emission controls. However, the proposed language In the standard goes beyond this, Vista believes the VAB.0001178362
*
1
intended purpose seated in the preamble is reasonable. If Subpart V is triggered, only the sections applicable to valve monitoring should be required. Implementing all of Subpart V would require capital expenditures to comply with a number of requirements. Although the LD&E portions of the VC NESHAPrs are substantially the same aa Subpart V they are not precisely the same. We believe fugitives are adequately controlled under both programs*
As proposed. Section 61.65(b)(1)(11)(E) requires monitoring in compliance with the valve monitoring of Subpart V within 90 days
upon finding greater than 2X of valvee leaking. We believe the
goal to keep leaks repaired can still be met by allowing the plant to retest its valves within 30 days; if the plant falls the retest, Subpart V valve monitoring must be adopted for one year. Allowing a quick retest would give the plant an opportunity to evaluate its shortcomings and correct them quickly whether they be actual leaks, instrument or operating problems, or other random errors. We believe most plants would quickly solve problems in order to avoid implementing Subpart V valve monitoring. Plants should also be allowed to revert back to the provisions of 61.65(b)(8)(ii)(B) after a period of time under Subpart V valve monitoring. We suggest that a year under Subpart V valve monitoring should convince most plants to keep better control of valve leaks.
Considering the above, we suggest 61.63(b)(8)(ii)(E) be revised to reads
"(E) Any process unit In which the percentage of leaking valves is found to be greater than 2.0 percent must retest in accordance with this Section within 30 days. If, after retest, the percentage of valves leaking is greater than 2.0 percent, the process unit must comply with all valve monitoring provisions of Subpart V for one year."
5. Product Accumulators - Subpart V Section 61.242-9 This section should be modified to specify that vents from
process accumulators in VHAP service must be controlled. As written, this section could be iInterpreted to mean that all fugitive sources on a product accumulator must be controlled, We don't believe this is EPA's intent.
6. Multiple Relief Valve Discharges 61.65(a)(4) Additional language should be included In 61.65(a)(4) to assure
the multiple relief valve discharges that occur because of one overpressure event be considered only one discharge. EPA states In the preamble on page 1189;
"...for determining compliance with the numerical limits, discharge frequency is to be recorded on the basis of Individual discharges except when simultaneous discharges occur from relief valves on the same piece of equipment,"
Typically PVC reactors are outfitted with several relief valvee set to relieve at Increasingly hlghsr pressures. This is considered good design practice since the amount of a release <5&B-0001178363
1
be better minimized. If necessary more than one of the relief valves could discharge, but not necessarily exactly at the same time since they could be set to relieve at different pressures* EPA. appears to recognize this possibility In the preamble quoted above* However, the requirement that discharges be simultaneous should be eliminated* Rather, multiple releaaes that occur becaui of a single over pressure event should be considered one release.
We suggest that 61.65(e)(4) be revised by adding the sentence:
"Multiple relief valve dischargee from the same veesel or equipment occurring because of a single overpressure event are considered to be one discharge,"
7. Slurry Stripping Calculation Section 61*67 We believe that the constant lT used In the equation to
calculate C in 61*67(g)(6)(111) should be 1,002 (1.002 x 10s) not 1.002* Also, in 61.67(g)(6)(il)(B), PPVA should be PPVC.
8. Fugitive emissions - Section 61.65(b)(8) There le a typographical error In 61.65(b)(8)(11)(A), The
reference should be (b) (8) (il) (B) not (b)(8)(11)(C).
9. Reporting - Section 61.70(f) Reporting of design capacity required by 61.70(f) should not be
required. This is proprietary information and should not be in the public record. Plants that strip in reactors using the test proposed In 61.67(g)(6) should not bs required to provide this information since it le not relevant for compliance determlnetion* Other plante should be allowed to provide this information In a separate confidential document.
10, Emission Standard For EDC Plants - Section 61.62 This standard is unclear as to whether tank, area vents are
Included under this definition.
We urge EPA to consider these comments and contact us if additional information or clarification is necessary. Your decision on Subpart Vl is lmportsnt to our company. We remain reedy to discuss these comments and fugitive emission controls at your convenience. Sincerely,
J. C. Ledvlna, Director Environmental Activities