Document Gz1mpxXp2aJBM42aZwO8Eov4n

FILE NAME: Electrical Insulation (ELEC) DATE: 1999 DOC#: ELEC009 DOCUMENT DESCRIPTION: Article from Scientific Journal MICROSCOPE Vol 47:3 159-161(1999) Microscopical Studies of Asbestos Fiber Release During Cutting and Stripping of Wire Cables JAMES R. MILLETTE, MVA, Inc. * MICHAEL D. MOUNT, Cape Environmental Management, Inc. ** KEYWORDS Asbestos, Wire cable, Polarized light microscopy, Phase contrast microscopy, Transmission electron microscopy. ABSTRACT Microscopical tests including polarized light microscopy (PLM), phase contrast microscopy (PCM), and transmission electron microscopy (TEM) were used in the testing for possible fiber release during cutting and stripping of wire cables that contain asbestos insulation. The testing was done in con trolled plastic enclosures large enough for a worker to cut and strip wire cables as had been done for making electrical connections. The concentrations of airborne fibers greater than 5 urn in length were not signifi cantly different from the detection limits during cut ting and stripping of the four wire cables containing asbestos that were tested. The concentrations of asbestos fibers of all sizes in the air (TEM concentra tions) were not increased over detection limits. INTRODUCTION Wire cables used to carry electrical power have been known to contain asbestos fibers in their insulating covers. The cutting and stripping of wire cables may release asbestos dust. This study was designed to determine under controlled conditions, the levels of asbestos, if any, which might be released into the air when four different types of asbestos-containing wire cables were cut and stripped. MICROSCOPICAL METHODS Polarized light microscopy techniques for the analysis of bulk samples were used to determine whether the wire cable samples contained asbestos fibers in their insulation (1). Air samples are analyzed for asbestos using both light and electron microscope techniques. The stan dard procedure for the analysis of air samples for asbestos in an occupational environment is the National Institute of Occupational Safety and Health (NIOSH) Method 7400 (2). This procedure uses PCM to count fibers greater than 5 [xmin length and greater than a 3 to 1 aspect ratio. The method counts all fibers seen at 400X magnification without distinguishing asbestos fibers from other fibers. It only counts fibers greater than approximately 0.25 [xm in diameter, the optical resolution limit of the PCM. A draft version of International Standards Organ ization (ISO) Standard Method for the analysis of directly prepared air filters for asbestos by transmis sion electron microscope was used to provide infor mation about the asbestos structures in the air sam ples (3). This method eventually became the standard method for ambient air by TEM: ISO 10312. Asbestos structures containing asbestos fibers greater than 0.5 [xmin length were counted using this technique. STUDY SITE The study was conducted in a warehouse in Norcross, Georgia. The study team conducted the wire cable cutting and stripping tests after an asbestos abate ment contractor had prepared a containment area with four chambers. The containment barriers in each area consisted of two layers of 6-mil polyethylene plastic sheets on the floor, walls and ceiling of each chamber. The total containment area was approxi mately 150 square feet with an 8-foot ceiling height and 4 individual chambers each 4 feet by 8 feet (32 square feet). All personnel inside the containment area were protected by air purifying respirators and complete head and body coverings. The decontami nation system consisted of a changing room outside the testing area, a shower room and a clean suitup room. The decontamination system was used each time a person exited the study area. *5500 Oakbrook Parkway, #200, Norcross, GA 30093 ** 2302 Parklake Dr., Suite 200, Atlanta, GA 30345 159 EQUIPMENT Asbestos analysis was done by PLM utilizing an Olympus BH-2 polarized light microscope having a magnification range from 40X to 1000X. The air sam ples were analyzed by PCM with a Nikon Alphaphot2 light microscope and by TEM with an analytical Phillips 400 electron microscope (AEM) equipped with an EDS X-ray analysis system. MATERIALS Four (4) different wire cables of 1.125 or 1.25 inch diameter were tested. Each cable contained a ribbon inside the outer covering which identified the manu facturer. Based on PLM, all cables contained chrysotile asbestos inside the outer cover. Descriptive information for the product materials follows: Experiment #1. Sample MDGA-19(14) was a 1.25 inch diameter cable with 20 copper wires, woven steel sheath with a rubber-like black insulating coating. The interior ribbon read: "General Cable Corporation, Bayonne, NJ, 1967 MIL-C-915A". Experiment #2. Sample THFA-30 was a 1.125 inch diameter cable with 3 copper wires with a woven metal sheath on black rubber-like coating. The interi or ribbon read: "Md'd. by Phelps Dodge Copper Products Corp. - Habirshaw Cable & Wire Division, Yonkers, NY 1944 Navy". Experiment #3. Sample MHFF-37 was a 1.25 inch diameter cable with 8 copper wires (color coded) in a black rubber-like coating. The interior ribbon read: "U.S. Steel Corp. Worchester, Mass. 1957 to U.S. Navy Specs MIL-C-915A". Experiment #4. Sample MHFF-30 was a 1.125 inch diameter cable with over 20 color-coded copper wires. The interior ribbon read: " General Cable Corporation Eltkton, MD 1968 MIL-C-915-A". PARTICLE RELEASE TESTING In the controlled containment areas, background area air samples were collected before any work was performed on the wire cables. The rooms were aggressively swept with a broom during the collec tion of the background samples. Area air samples and personal monitoring samples were collected while the material was cut (in a dry condition) with a hack saw and the wires stripped of insulation. For each of the cables, a piece of wire cable was cut and the individ ual wires stripped as would be done for making an electrical connection. The cutting and stripping was done after discussions with an electrician who had worked in shipyards for many years installing this type of material. Air samples using mixed cellulose ester filters were collected during the cutting and stripping. Each activity tested lasted about 30 minutes. Separate air samples were also collected during a dry broom sweeping period which lasted approximately 5 min utes. The person cutting and stripping the cables was fitted with two personal air sampling devices. Two area air samples were also collected. The personal air samples were collected at rates of 0.8 and 1.9 liters per minute. One area air sample was collected with a per sonal air pump at a rate of 2.5 liters per minute. The other was collected at a rate of approximately 5.1 liters per minute. RESULTS The results of air monitoring are summarized in Tables 1 - 4 . The asbestos concentration values of the area samples were always less than those of the per sonal samples. The limits of detection varied with the volume of air collected. The PCM concentrations of airborne fibers greater than 5 pm in length were either at or below the detection limits of the method during cutting and stripping of the wire cables tested. The concentrations of asbestos fibers of all sizes in the air (TEM concentrations) were not increased significantly over detection limit values during the cutting and stripping of the wire cables containing asbestos. REFERENCES 1. McCrone, W.C.; "Routine Detection and Identifica tion of Asbestos"; Microscope 1985, 33, 273-284. 2. Carter, J.W., Taylor, D.G., Baron, P.A; NIOSH Method 7400, NIOSH Manual of Analytical Methods, 4th Ed., U.S. Department of HHS, 7400-1 - 7400-8, 1984 3. "Ambient Air-Determination of Asbestos Fibres Direct-transfer Transmission Electron Microscopy Procedure"; International Standards Organization, 1995. ISO 10312. Available from the American National Standards Institute, 11 W. 42nd St., 13th Floor, New York, NY 10036 (212-642-4900) 160 MICROSCOPE(1999)47 Sample Description Background Background Personal During Stripping Personal During Stripping Personal During Sweeping Personal During Sweeping Sample Description Background Background Personal During Stripping Personal During Stripping Personal During Sweeping Personal During Sweeping JAMES R. MILLETTE and MICHAEL D. MOUNT Table 1. Results of Experiment #1, Cable MDGA-19(14) Air Volume (L) PCM 7400 Fibers*/ 790 0.007 790 <0.003 57 <0.05 25 0.11 11 <0.2 5 <0.5 TEM Structures**/ <0.006 Not Analyzed 0.08 0.8 0.4 <0.95 Table 2. Results of Experiment #2, Cable THFA-30 Air Volume (L) PCM 7400 Fibers*/: 790 <0.003 790 0.006 57 <0.04 25 <0.1 11 <0.4 5 <0.6 TEM Structures**/ <0.006 Not Analyzed 0.2 <0.2 <0.5 <1.1 Sample Description Background Background Personal During Stripping Personal During Stripping Personal During Sweeping Personal During Sweeping Table 3. Results of Experiment #3, Cable MHFF-37 Air Volume (L) 790 790 57 25 11 5 PCM 7400 Fibers*/ <0.003 0.007 <0.04 <0.1 <0.2 <0.5 TEM Structures**/ <0.006 Not Analyzed 0.3 0.2 <0.4 <0.95 Sample Description Background Background Personal During Stripping Personal During Stripping Personal During Sweeping Personal During Sweeping Table 4 Results of Experiment #4, Cable MHFF-30 Air Volume (L) PCM 7400 Fibers*/ 790 0.015 790 0.01 57 0.06 25 <0.1 11 <0.3 5 <0.6 * Fibers > 5 (jtmin length ** Structures contain asbestos fibers > 0.5 (mi in length TEM Structures**/ 0.006 Not Analyzed <0.08 <0.2 <0.5 <0.9 161 LOMO POLAM Polarized Light Microscopes The LOMO POLAMTM family of Polarized Light microscopes, distributed in the US by LOMO America, Inc. of Prospect Heights, Illinois has an amazing number of capabilities considering its price range from $5000 to $7500. Designed by American and Russian engineers and built by LOMO PLC (St.Petersburg, Russia), one of Europeis oldest and most advanced optical manu facturers, the POLAM( series combines the highest optical quality and unsurpassed versatility with many unique features unavailable from any other microscope manufacturer in the world. POLAM( is capable of transmitted light studies in polarized light, bright field, phase-contrast, dark field, and can utilize dispersion staining technique. POSITIVE FEATURES FROM BOTH MECHANICAL AND OPTICAL STANDPOINTS INCLUDE: Stand -- Rugged and stable tripod frame provides focusing and attachment of the light source, stage, condenser, and head. Coaxial low-position coarse/fine focusing with graduated vernier scale. Illumination -- True Khler illumination with built-in field iris diaphragm, focusable collector lens system and a variable intensity 9V / 70W halogen bulb. Heads -- Your choice of binocular or trinocular heads with built-in iris diaphragm for greatly improved viewing of interference figures. The interpupillar distance is adjustable from 56mm to 75mm. Objectives -- The objectives are all stain-free Plan Achromats. They are 2.5x 0.05 N.A., lOx 0.20 N.A. (with iris diaphragm), 25x 50 N.A. phase contrast, 40x 0.65 N.A. brightfield. 6-x 0.85 N.A., and lOOx 1.25 N.A. Eyepieces -- Three lOx eyepieces are supplied: one general purpose, one with cross hairs, and another accepting a grid or a scale reticle (inluded)Analyzer: The analyzer is rotatable 180deg. with vernier reading to 0.1 deg. There is a slot in the adapter tube to accommodate compensator plates. Nosepiece -- The precision ball-bearing nosepiece accommodates five indepen dently centerable objectives. Stage -- Rotating ball-bearing stage with vernier reading to O.ldeg. The 45deg. stops may be turned on and off. Supplied with stage clips and a detachable mechani cal stage. Options -- LOMO's unique and patented monochrometer is ideal for determining reflective indexes. It consists of a disc with six interference filters, which may be set at different angles to produce light in the 400nm to 700nm region. Dimensions -- 20i x 22i x 8i; Weight: 9.5kg/211b. Unlike the competition, the Bertrand lens (focusable and centerable) is a standard feature on POLAMTM microscopes. The POLAMTM microscopes have many attractive design features, suitable for a variety of applications in analytical chemistry, forensics, environmental science, mineralogy, crystallography and many more. The features and quality of this product provid ed with LOMOis Limited Lifetime Warranty result in a microscope surpassing its peers of other world-renowned brands.