Document Gmpyg9GLLnRdEZk8LdGY2dVxv

OJU - CU 7 (/ r - UNION CARBIDE CORPORATION ENGINEERING AND HYDROCARBONS DIVISION CENTRAL ENGINEERING SOOTH CHARLESTON, WEST YfRCiNIA MEMORANDUM June 26, 1981 TO: Mr. I. P. Blackwood Mr. V. H. Johnkoski Mr. J. A. Leonard Mr. J. B. Leverton Mr. K. G. Morlock Mr. T. P. R&by Mr. -R. A. Ream Mr. A. M. Robertson Mr. R. J. TayloT Mr. J. L. Wyatt SHARE MGRS. Mr. T. L. Collins Dr. R. E. Plevan Mr. R. C. Wise COPY TO: Mr. W. J. Hansen Mr. E. C. Powell, Jr. Mr. H. W. Wegert FROM: Mr. D. T. Watters SUBJECT: Potential Health Risks Insulation Materials A March 17, 1981, E. C. Pbwell, Jr. memorandum to E. L. Adkins of Institute and a June 3, 1981, R. W. Cope letter to Component Health Managers and HS S EA Industrial Hygienists have described an insulation potential health risk. In response to these communications several of you have asked. Are substitute Materials (not asbestos) available where appropriate? Some background, our answer to the question, and proposed action is as fol1ows. 1. The involved insulation. Insulation Specification 4 (copy attached), manu factured by Goodtemp Corporation and Celotex Corporation, is selected for ethylene oxide service because it gives a combination of the safest (i.e. highest) autoignition temperature to a laboratory simulated piping leak of ethylene oxide and excellent fire resistivity. The specification notes inhalation of perlite dust may cause irritations. 2. The complaints at Institute are the first to reach our attention during the past 3-4 years. The insulation vendors state no prior reports of health concerns. No other Locations have indicated excessive irritations. 3. Depending on ambient conditions, handling, and the amount of fitting required for the job, any insulation has the potential to create nuisance dust and irritations in-some people. Respiratory protection in addition to good r industrial hygiene practices can best be used where irritations seem to be isolated instances. UCC 011906 Mr. I. P. Blackwood, et. al. je june 26, 1981 4. Some Locations are probably using the specifications beyond the specific need in ethylene oxide service. If this is the case, an alternate specification might be used on other than ethylene oxide fluids. 5. Based on the desired safety performance of Insulation Specification 4 in ethylene oxide fluid service, and the apparent infrequent complaints noted in the communications, we recommend continued use of Specification 4 with respiratory protection used as needed by individuals. Numerous autoignition tests have been run in the Safety Research Laboratory and it is clearly demonstrated that a substitute insulation is not readily available. 6. If your Location receives complaints similar to those described in the March 17 and June 3 communications, please pass them to the Central Engineering Department Insulation Technologist, Ernie Powell, Ext.. 4419, plus other interested Division Safety/Health Managers. There is concern for the health of our employees and if additional complaints axe received, it may be desirable to trade an increment of safety on the autoignition data, for improved insulation health characteristics. However, any insulation will give some degree of dusting. If you have comment relative to the above six items, please let us know. We will request the subject be an agenda item at the next S/H Managers meeting. DTW:abg ----------------------------------------------------------------------------- D. T. Watters UCC 011907