Draft: Prepared at the Request of Council
AR226-2623
Data and Modeling Procedures
Dispersion modeling was performed using the U.S. EPA's Screens model. This model is a screening tool which gives predictions of ambient ground level concentrations for a single stack. Due to the assumptions
made in the model, particularly those regarding meteorological conditions, these predictions will always be more conservative than predictions made by the ISC3 model.
There is one source ofAPFO emissions on the Circleville site....ctescn6e emission source. The following parameters for this source were used in the model:
Stack Height: 65 feet
Diameter: 15.5 inches Temperature: 303F Flow Rate: 1927acfm C8 Emission Rate: 130
kg/yr
The C8 emission rate is based on mass balance estimates provided by the site.
To determine the impacts of building downwash on dispersion from the stack, the Screen3 model uses only the dominant downwash structure as an input to the model. The dominant downwash structure can be found by first locating all buildings which have an area of influence encompassing the stack. The area of influence is defined by EPA as a distance of five times the lesser of the height or the maximum projected width of the building. Once all of the potential downwash structures are located, the dominant downwash structure is determined by calculating the GEP (Good Engineering Practice) stack height for each building. The building with the greatest GEP stack height is the building that should be included in the Screen3 model. The GEP stack height is calculated according to the following formula:
H=h+1.5L
where H = GEP stack height
h = building height L = lesser of the building height or maximum projected width
The following table shows the buildings that were included in the downwash analysis and their respective GEP's:
Building
Height (ft)
Length (ft)
Width (ft)
Max Projected
Width (ft)
GEP (ft)
Coating
52
92
62
111
Powerhouse
35
67
25
72
EP*
60
50
50
71
Building 3
35
150
150
212
This building has the highest GEP and was used in the model.
130
87.5 150
87.5
Modeling Results
Using the above data the Screen3 model predicted a maximum off-site ground level concentration of
1.306 i-ig/m3 at a distance of 1500 feet from the source. This concentration is based on a 1-hour averaging time. To convert a Screen3 model result to an annual average, EPA guidance directs the user to multiply the predicted Screen3 concentration by a value of 0.05. This gives an annual average concentration of 0.065 (ig/m3. A copy of the Screen3 model output is attached.
Draft: Prepared at the Request of Council
07/23/2004
*** SCREEN3 MODEL RUN *** *** VERSION DATED 96043 ***
13:25:05
CIRCLEVILLE APFO EMISSIONS ** 0
SIMPLE TERRAIN INPUTS:
SOURCE TYPE
=
EMISSION RATE (G/S)
=
STACK HEIGHT (M)
=
STK INSIDE DIAM (M)
=
STK EXIT VELOCITY (M/S)= STK GAS EXIT TEMP (K) =
AMBIENT AIR TEMP (K)
=
RECEPTOR HEIGHT (M)
=
URBAN/RURAL OPTION
=
BUILDING HEIGHT (M)
=
MIN HORIZ BLDG DIM (M) =
MAX HORIZ BLDG DIM (M) =
POINT
0.412200E-02 19.8120 0.3937 7.4706
423.7056 293.0000
0.0000
RURAL
18.2880 15.2400 15.2400
THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED. THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.
STACK EXIT VELOCITY WAS CALCULATED PROM
VOLUME FLOW RATE = 0.90944278
(M**3/S)
BUOY. FLUX =
0.876 M**4/S**3; MOM. FLUX =
1.495 M**4/S**2.
*** PULL METEOROLOGY ***
*** SCREEN AUTOMATED DISTANCES ***
*** TERRAIN HEIGHT OF
0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***
DIST
(M)
CONC
(UG/M* *3)
STAB
U10M (M/S)
USTK
(M/S)
MIX HT
(M)
PL UME HT (M)
SI'GMA
y (M)
SI'QMA Z (M)
DWASH
457. 500. 600. 700. 800. 900. 1000. 1100. 1200. 1300.
1400. 1500.
1.306 1.213 1.042 0.9144 0.8110 0.7331 0.6687 0.6146 0.5685 0.5286 0.4937 0.4629
6
1.0
1.5 10000.0 24 .01 16 .55 19 .46
SS
6
1.0
1.5 10000.0 24 .01 17 .97 19 .77
SS
6
1.0
1.5 10000.0 24 .01 21 .24 20 .48
SS
6
1.0
1.5 10000.0 24 .01 24 .46 21 .18
SS
6
1.0
1.5 10000.0 24 .01 27 .63 21 .34
SS
6
1.0
1.5 10000.0 24 .01 30 .78 21 .97
SS
6
1.0
1.5 10000.0 24 .01 33 .88 22 .55
SS
6
1.0 1.5 10000.0 24 .01 36 .96 23 .11
SS
6
1.0
1.5 10000.0 24 .01 40 .01 23 .66
SS
6
1.0
1.5 10000.0 24 .01 43 .04 24 .20
SS
6
1-0
1.5 10000.0 24 .01 46 .05 24 .73
SS
6
1.0
1.5 10000.0 24 .01 49 .03 25 .26
SS
MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 457. M:
457. 1.306
6
1.0
1.5 10000.0 24.01 16.55 19.46
SS
DWASH= DWASH=NO DWASH=HS DWASH=SS DWASH=NA
MEANS MEANS MEANS MEANS MEANS
NO CALC MADE (CONC = 0.0)
NO BUILDING DOWNWASH USED HUBER-SNYDER DOWNWASH USED
SCHULMAN-SCIRE DOWNWASH USED
DOWNWASH NOT APPLICABLE, X<3*LB
*** REGULATORY (Default) ***
PERFORMING CAVITY CALCULATIONS
WITH ORIGINAL SCREEN CAVITY MODEL
(BRODE, 1988)
Draft: Prepared at the Request of Council
*** CAVITY CALCULATION -
COMC (UG/M**3) CRIT MS @10M (M/S) = CRIT WS 8 HS (M/S) =
DILUTION WS (M/S) = CAVITY HT (M) CAVITY LENGTH (M) = ALONGWIND DIM (M) =
1 ***
9. 860 1 .00 1 .15
1 .00 28 .19 25 .71 15 .24
END OF CAVITY CALCULATIONS
*** * *: CAVITY CALCULATION -
COMC (UG/M**3)
=
CCRIT WS @10M (M/S) =
CCRIT WS @ HS (M/S) =
EDILUTION WS (M/S) =
CCAVITY HT (M)
=
CCAVITY LENGTH (M) =
aALONGWIND DIM (M) =
2 ***
9.860
1.00
1.15 1.00 28.19 25.71 15.24
*** SUMMARY OF SCREEN MODEL RESULTS ***
CALCULATION PROCEDURE
SIMPLE TERRAIN BLDG. CAVITY-1 BLDG. CAVITY-2
MAX 0 ONC
(UG/M* *3)
1.306 9.860 9.860
DIST TO
MAX (M)
457. 26. 26.
TERIIAIN HT (M)
0.
-- (DIST = CAVITY LENGTH)
(DIST = CAVITY LENGTH)
Note: The off-site concentration referenced in the report is the concentration shown for simple terrain. Although the model predicted a building cavity concentration that is higher than the predicted value for simple terrain, this concentration will occur on site and is not applicable for this analysis.