MINUTES
of the
-TECHNICAL. 8t RESEARCH COMMITTEE MEETING
NATIONAL. INSULATION MANUFACTURERS ASSOCIATION
New York, N. Y.
January 30, 1964
Rock 8c Slag Section
Glass Section
The meeting was called to order by V/. Gubar with the following in attend ance from the Glass and Rock &c Slag Sections,
ffm, Anderson K. M. Ritchie C. E, Ernst F. E. Losse W. T. Irwin T. S, Clousing H, M. Grant W. Gubar Russel Austin
Owens-Corning Fiberglas Corp, Baldwin-Ehret-Hill, Inc, The Johns-Manville Sales Corp. The Eagle-Picher Company Pittsburgh Plate Glass Co, M. H, Detrick Company v Gustin-Bacon Mfg. Company Gustin-Bacon Mfg. Company Gustin-Bacon Mfg. Company
The topics for discussion were taken up in accordance with J. M. Barnhart's letter of December 19, 1963,
PROPOSED FEDERAL SPECIFICATION FOR MINERAL FIBER (FOR. ELEVATED TEMPERATURES) INTERIM. SPECIFICATION HH-I-00558
(1) Owens Corning requested a change in the Form B type IV use temper ature from 400 to 250 F. It was their contention that the OC Aerocor type blanket is not recommended for use at temperatures up to 400F. It was suggested by Jack Barnhart that two types of resilient blankets be incorporated in the specification; one for 250 F and the other for
400 F.
(2) The following changes were recommended in Table I page 2.
(a) e and f classes should be under CVH (b) g class should be under CVIH (c) Add h and j classes for pipe sizes 3" and above
under Type V IIL
(3) Under specification on page 3 add ASTM C-177 and C-335.
2
(4) Change the certification on page 2 by deleting the phrase "to have successfully completed tests" to read, "The thermal insulation offered under this specification when required shall be certified by the manufacturer for----------- . "
(5) Since the requirements and procedures for test were not congruent it was decided to have Jack Barnhart rewrite the requirements as in the original specification. This shall be scaled down to conform to the standard 8 x 10-1/2 specifica tion sheet.
PROPOSED FEDERAL SPECIFICATION FOR MINERAL FIBER (LOW TEMPERATURE) INTERIM SPECIFICATION HH-I-00559
This specification was not reviewed. Jack Barnhart is to rewrite this specification in the same format as HH-I-00558.
PROPOSED FEDERAL. SPECIFICATION - INSULATION, FEET, THERMAE AND ACOUSTICAL, MINERAL, FIBER (DUCT LINING MATERIALS)
The NIMA draft of this specification was sent to Mr. R, E, Lyons, General
Service Administration, December 13, 1963. No comments were received
from Mr. Lyons,
\
ELIMINATION OF FIBER DIAMETER REQUIREMENTS FROM GOVERNMENT SPECIFICATIONS
(1) It was decided by this group that the federal specification should have the fiber diameter deleted from the specifications.
(2) In the MILITARY specifications, the fiber diameter serves a useful purpose in characterizing the type of product and its properties other than thermal conductivity,
CONDENSATION THICKNESSES
This subject was discussed at some length and no agreement could be reached for a standard condition. A standard condition would serve one purpose and that is the reporting of company data. Engineers would still have to calculate wall thicknesses to their respective conditions,
TECHNICAL PRACTICABILITY OP ELIMINATION OF 1/2 PCF OR 3/4 PCF BLANKET PRODUCT AND 1/2" AND/OR 3/4" THICKNESS PIPE INSULATION
(1) The elimination of the 1/2" or 3/4" pipe insulation thicknesses could not be resolved. The 1/2" wall thickness is used exclusively at room temp to 250 F. The 3/4" is used on chilled water lines (50F),
3
(2) The design conditions of 90DB and 80 V/B v/hich the majority of the manufacturers use set the wall thickness at 3/4". the committee stated if a particular ambient condition is chosen to give a 1" minimum thickness, an outside source must be consider ed for justification of this design condition.
FACINGS
W. Gubar presented his data to the committee. Jack Barnhart is to circulate this information for comment,
R-FACTORS
This subject was discussed briefly. Since this subject is to be on the March 1, 1964 agenda, no decision was reached.
Respectfully submitted
W. GUBAR