Document GmZ1NJ3xa7n5Bj1GmwnN03mZr

Therminol Conversion... INTERIM BULLETIN SP-1TC "Nothing contained herein is to be construed as a recommendation to use any product in conflict with any patent. MONSANTO MAKES NO WARRANTIES AS TO THE FITNESS OR MERCHANTABILITY Of ANY PRODUCT REFERRED TO, no guarantee of satisfactory results from reliance upon contained information or recommendations, and disclaims all liability for any resulting loss or damage." 0585959 TOWOLDMONOQ37168 THERMINOL CONVERSION BULLETIN INTRODUCTION . ' Therminol FR fire-resistant heat transfer fluids have long provided safe, dependable, economical performance for hundreds of users in dozens of appli cations. The presence of poly-chlorinated biphenyl (PCB) in the Therminol FR formulation provided fire-resistance, giving Therminol FR an added margin of safety which was especially desirable in hazardous applications. Host recently, PCB has been identified as a potential hazard to the environ ment. Monsanto has accordingly elected to discontinue the manufacture and sale of Therminol FR fluids for heat transfer applications. This bulletin is to inform you about two alternative products sold by Monsanto which do not contain rCB, namely Therminol 55 and Therminol 66. These products offer most of the excellent heat transfer characteristics of Therminol FR fluids, and even a few additional advantages, such as a lower specific gravity for improved pumpability requiring less horsepower. We would point out that Therminol 55 and 66 are not fire-resistant to the extent the Therminol FR fluids were, and due consideration must be given this fact in con verting to these newer Therminol fluids. You may wish to consult with your insurers on any conversion from Therminol FR. .Conversion from a Therminol FR fluid to a Therminol 55 or 66 fluid will be a relatively simple, low-cost procedure in the majority of cases. Incorporation of proper fire protection equipment will be the only consideration of major consequence in most cases. But even this modification becomes academic, for 0585960 TOWOLDMONOQ37169 with the discontinuation of Therminol FR fluids, fire protection equipment becomes necessary for any and all' low pressure heat transfer media available today, since the Therminol FR fluids were unique in their fire-resistance. Should questions arise with respect to the conversion from Therminol FR fluid, Monsanto's Specialty Products Group invites you to call upon its staff or qualified systems engineers for consultation at any time. Call,,. (314) 694-2514 and ask for a Monsanto Heat Transfer Specialist. Therminol 55 and 66 and Your Heat Transfer System Table I shows the typical physical, chemical and thermal properties of Therminol FR-1, Therminol 55 and Therminol 66. As you will note, Therminol 55 and 66 are quite similar except with regard to AIT, Fire Point and density. The substantially lower density of Therminol 55 and 66 means that pumps used in a Therminol FR-1 system should be adequate for a Therminol 55 and 66 system. In most cases, pumping rates will be increased with a resultant saving in horsepower requirements. Therminol 55 and 66 have outstanding heat transfer properties, so heating and cooling performance will not be sacrificed in a change from Therminol FR-1. The specific heat and thermal conductivity of Therminol 55 and 66 are shown, along with other physical properties, in Tables 2, 3 and 4, and in Figures 1, 2 and 3. The lower pour points of Therminol 55 and 66 will provide easier cold startup of the system. Generally speaking, then, a well designed system currently operating on Therminol FR-1 can be converted to Therminol 55 and 66 with few, if any, basic -2 0535961 TOWOLDMONOQ37170 TABLE I ' TYPICAL PHYSICAL, CHEMICAL & THERMAL PROPERTIES Therminol FR 1 Therminol 66 Therminol 55 Composition Maximum Bilk Temperature Rating (F.) Recommended Use Range (F.) Pour Point (F.) Pounds/Gallon (75F.) Flash Point (F.) Fire Point (F.) AIT (F.) '' Boiling Range (F.) Molecular Weight Expansion Coefficient cc/cc/ F. Polychlorinated Biphenyl 600F 45 - 575F. 2 11.55 350 None to Boiling 1206F. 620 - 680 265 0.00031 Modified Terphenyl 650F. Alkylated Aromatic 600F. 45 - 635F. -15 8.35 355 374 - 392 705 644 - 745 240 0.00039 20 - 575; -40 7.4 355 410 670 635 - 734 340 0.00047 -3- 0585962 TOWOLDMONOQ37171 Table 2 THEBMINOL FB-1 VAHIATION OP PROPERTIES WITH TEMPERATURE Tempe rature Dens Ity Specific Keat Thermal Conductivity Viscosity Vapor Pressure P C lb/ Xg/m3 BTU/lb Kcal/Kg gal F C 50 10 11.68 1399.6 0.272 0.272 100 33 11.46 1372.7- 0.282 0.282 150 66 11.22 1343.7 0.291 0.291 200 93 10.99 1316.7 0.3047 0.3047 250 121 10.76 1289.1 0.3151 0.3151 300 149 10.53 1261.3 0.3255 0.3255 350 177 10.30 1233.5 0.3359 0.3359 400 204 10.07 1205.8 0.3464 0.3464 450 232 9.83 1178.0 0.3568 ' 0.3568 5C0 260 9.60 1150.2 O.3672 0.3672 550 288 9.37 1122.5 0.3776 0.3776 600 316 650 343 9.14 8.91 1094.7 0.3880 1066.9 .0.3985 0.3880 0.3985 700 371 8.68 1039.3 0.4089 0.4089 BTU/ft Kcal/m hr P hr C 0.06098 0.0907 O.O606C 0.0902 0.0602] 0.0896 0.0597- 0.0889 0.0592't 0.0882 0.0587! 0.0874 0.0581! 0.0866 0.0576c 0.0857 0.0569] 0.0848 0.0563c 0.0838 0.0556c 0.0827 0.0548] 0.0817 0.0540: 0.0805 0.0532! 0.0793 Cp Cs mmKg | Kg/cm2 absolute 308 220 - 23.2 6.6 16.9 4.9 -_ -' - 3-4 2.6 -' - 2-3 1.8 - - 1.4 1.1 '- ' - 1.0 0.8 10 . 0.0136 0.8 0.7 27 0.0367 0.6 0.5 65 0.0834 0.5 0.4 143 0.1945 0.4 0.4 291 0.3958 0.4 0.3 550 0.7480 0.3 0.3 0.3 0.3 --- ... 18.8031a1 1.3218 * 31.9psla| 2.2429 0585963 TOWOLDMONOQ37172 Table 3. TESRMINOL 66 VARIATION OF PROPERTIES WITH TEMPERATURE 1 TempeS mature i A* c O Density Specific Keat lb/ Es/sn3 gal L_| ~s^rj 1040 1 BTU/lb CP 0.320 A.ca 1/teg C 0.320 Thermal Conductivity ETU/ft Kcal/m hr P hr C 0.0720 0.1072 50 16 8.51 1C20 . 0.350 0.350 0.0711 0.1058 ICO 38 8.34 1000 0.380 O.38O 0.0703 0.1046 150 66' 8.14 975 0.405 0.405 O.CS95 0.1034 200 93 7.91 950 0.430 0.430 0.0587 0.1022 250 12 X 7.77 930' 0.455 0.455 0.C578 0.1008 300 149 7.59 910 0.480 0.480 . 0.0670 0.0997 350 177 7-33 885 0.505 0.505 0.0662 0.0985 400 204 7.17 860 .0.530 0.530 0.0553 0.0972 450 ?32 7.04 840 0.555 0.555 O.CS45 0.0959 500 260 6.75 810 0.580 0.580 0.0537 0.0948 550 288 6.62 793 O.605 600. 316 6.42 770 0.630 550 843 js.24 750 0.655 h?i ! 6.09 _732- 0.680 0585964 0.605 0.630 0.655 O.680 . 0.0628 0.0935 0.0620 0.0923 0.0623 0.0912 0.0505 0.C900 Viscosity Cp Cs 62000 50000 255 28.0 250 28.0 9.75 4.18 10.0 4.40 2.42 2.60 1.55 1.06 1.70 1.20 0.77 O.58 0.45 0.35 0.90 0.69 0.55 0.46 0.34 0.27 0.20 0.44 O.36 0.28 Vapor Pressure r~T~ trjnHg | Kg/cm absolute 0.1 2.0 0.003 20.0 50.0 100.0 200.0 350.0 760.0 1000 0.C27 0.068 O.I36 0.272 0.476 1.034 1.350 TOWOLDMONOQ37173 Table 4 THEHMNOL 55 VARIATIONS OF PEOPEHTISS WITH TEHPEHATUBE Tempe rature Density Specific Heat #P c lb/ Kg/m3 BTU/lb ICcal/Ks gal F c 0 -18 .7.62 100 38 7.31 200 93 7.00 300 149 6.69 400 204 6.39 500 260 6.07 600 316 5.76 915 0.420 878 0.472 840 0.522 803 ' 0.572 766 7l 0--0> 691 0.620 0.670 0.718 0.420 0.472 0.522 0.572 0.620 A C~rr\ 0.718 Thermal Conductivity BTU/ftj Kca l/iD hr P | hr C 0.0813 0.1210 0.0784 0.1157 0.0753 0.1121 0.0724 0.1077 0.0692 0.1030 O.C561 0.C9S4 0.0530 0.0338 Viscosity Cp Cs 1472 1610 25.4 30.1 4.20 5.0 1.69 2.10 0.904 1.18 0.563 0.415 0.80 0.60 Vapor Pressure nanKs absolute Kg/cm 0.5 3.0 10 40 . 10O 250 '. 0.001 0.C04 0.014 0.054 0.136 0.330 Os* CD - UC> O - _i_____ ' V. TOWOLDMONOQ37174 S P E C IFIC HEA,T - B T U /L B . Figure 1 THEHMINOL FR-1 - PHYSICAL PBOPERTIES TOWOLDMONOQ37175 Figure 2 THEREINOL 66 - PHYSICAL PROPERTIES w SPECIFIC KEA.T 3TU/L3~ VISCOSITY -- C2MTI3TCK2 TOWOLDMONOQ37176 SP3CIFIC KEAT -- 3TU /L VISCOSITY -- C33TISTCX3S Figure 3 THEHMINOL 55 - PHYSICAL PROPERTIES TOWOLDMONOQ37177 changes in design -- and without sacrifice to heat transfer efficiency. With the similarity of the heat transfer properties of the three fluids thus established, let us turn to the important differences between Therminol FR-1 and Therminol 55 and 66: namely, fire resistance and oxidation-resistance. ' fFire-Resistance As stated in the Introduction to this bulletin, the Therminol FR fluids were unique in their inherent fire resistance. No other commonly used heat transfer medium could be so classified. Even so, the Therminol FR fluids could be made to bum under certain conditions, as indicated by their AIT of about 1200F. It is important to realize that Therminol 55 and 66 are less fire-resistant than Therminol FR-1, and to modify the heat transfer system accordingly, it is equally important to understand that Therminol 55 and 66 are not volatile, highly flammable fluids but rather combustible as defined by FM and NFPA (NFPA No. 321). Protecting the System There are two major fire protection considerations in changing to Therminol 55 or 66 -- system leakage and possible tube rupture (in the heater). The former is actually'part of the larger subject of good system maintenance, and should be considered regardless of the heat transfer medium employed. A tight, wellmaintained system is usually a good, safe system! Following are some suggestions to prevent leakage when you convert to Therminol 55 or 66. First, if your system has rotary mechanical seals, you should provide a spray shield and a drip pan with a drain to a collection sump. Canned and seal-less pumps offer excellent protection against leakage. TOWOLDMONOQ37178 The best way to prevent piping leakage is to weld all connections. Where you must have access, use raised-face flanges with appropriate gasketing and high-temperature bolting. Control of piping leaks is especially important, since fluid-soaked insulation poses a more serious hazard than the leaking fluid, itself. Organic compounds such as Therminol 55 and 66 exhibit a slow oxidation reaction with the air trapped inside the voids of the insulating material when system temperatures reach about 500F. Saturated insulation offers a large fuel surface in the face of poor heat dissipation conditions, and this, along with possible catalysis from the insulating material (magnesia, silicate-bonded asbestos or calcium silicate) can cause a temperature build-up in the mass. This temperature build-up can result in ignition of the fluid when the space between the piping and the saturated insulation is exposed to air (i.e., should the insulation be broken for' repair, etc.) This phenomenon is not fully understood, but appears to occur less with closed cell insulation than with the insulating materials mentioned above. Closed cell materials, then, are preferred, especially where leakage is a possibility despite all precautions. ' The principle*problem areas are near instrument connections, valve packing glands, flanges, and where cracks develop in relatively impermeable insulation cement adjacent to oil soaked insulation. To obviate this problem, eliminate any source of leakage promptly. Replace leaky gaskets, oil soaked insulation, and re-pack valve stems. Cover insulation where leaks might occur with a hydraulic setting, oil-resistant cement. In stall valves, where possible, with the stems in a horizontal position so that -5- 0585970 TOWOLDMONOQ37179 leaks will drip away from the insulation. And again, use closed cell insulating , materials on suspect piping areas. ' Tube Rupture In Fired Heaters . . Generally speaking, where fire protection is concerned, it is best to consult your insurance underwriter for guidance and councel. Likewise, you will want to discuss your fire safety equipment requirements with qualified suppliers of fire protection equipment. Selection and sizing of fire protection equipment is important to safeguard the installation. A commonly used method of preventing fire in the event of tube rupture in fired heaters is piping steam of CO2 as a snuffer into the combustion chamber of the heater. Usually a properly-sized line with a remote manual valve for activation is the preferred arrangement. This snuffer system could be automated by the use of an exhaust stack temperature switch. This switch would then energize a solenoid valve and alarm upon excessive temperature rise, automatically flood ing the chamber with a fire extinguishing agent. In practice the temperature switch is often set about 100F. over the normal ex haust temperature to prevent nuiance shutdowns. Where steam snuffer systems are used, it is a good idea to employ a steam trap to avoid slugging the com bustion chamber with water when the system activates, or is activated manually. You can obtain a basic guideline in the selection of CO2 protection equipment (again, it is best to consult your insurance underwriter) from the National Fire Protection Assn., 60 Batterymarch Street, Boston, Mass. 02110 AC 617 482-8755. NFPA Bulletin No. 12 dated 1968 should be requested. This bulletin should be helpful in determining the amount of CO2 and the concentration of CO2 f needed to extinguish a fire based on your specific application. "6` 0585971 TOWOLDMONOQ37180 CC>2 cylinders are available from Cardox Division of Chemetron, Chicago, 111. as well as other suppliers. Some standard sizes are 50, 75, 100 and 150 pound cylinders. Prices usually include drawings of the units, fully charged cylinders, flexible piping connectors, spray nozzle, pressure switch, alarm and automatic control, provided C02 release signal is supplied by customer device. Piping, wiring, and installation labor to be provided by the customer. Recharging of spent cylinders is available at an additional cost from a variety of "Fire & Safety Equipment Suppliers" listed in the Yellow Pages of your phone book. Selection of all equipment and installation recommendations should be obtained from qualified suppliers; however, it is important to insure that sufficient C(>2 is available to prevent re-ignition while the heater is cooling. The HaIon Fire Suppression System is a possible alternative to a CO2 arrange ment because it can be used in closed spaces with personnel in the area. One supplier of Halon systems is the Cardox Division of Chemetron Corporation, Chicago, 111. 60611. Again, we strongly recommend that the advice of fire protection companies be solicited in either case to insure proper equipment selection and installation. If steam is to be used rather than the other alternatives suggested above, please refer to the NFPA Volume I, Section 86A (1970-1971) to obtain the volume of steam required. Oxidation-Resistance With a Therminol 55 or 66 system, some provision should be made to prevent oxidation caused by air contact at fluid temperatures exceeding 200F. This was not the case with Therminol FR fluids, but must be observed for Therminol 55 ,, 0585972 TOWOLDMONOQ37181 and Therminol 66. Oxidation can result in sludge formation, eventually leading to carbonaceous deposits on heat transfer surfaces and at mechanical seal faces. Oxidation of fluid can develop by air contact in an open, vented expansion tank. Therefore we recommend that the expansion tank be blanketed with an inert gas (such as nitrogen) as shown in Figure 4. If this is not possible, air contact can be minimized by a cold seal arrangement as shown in Figure 5, An inert gas pressure of one to two psi is adequate, as Therminol 55 and 66 do. not require pressurization to maintain liquid phase. .You can design the cold seal arrangement quite simply by piping the expansion tank vent to a second tank where the vent line projects subsurface and can be flooded with additional Therminol 55 or 66 to minimize air ingress to the ex pansion tank vapor space. In converting from Therminol FR to Therminol 55 or 66, it is important to remember that many Therminol I'R systems were designed with a hot bleed line into the expansion tank to eliminate moisture accumulation. Moisture accumula tion in the presence of hydrogen chloride gas released during the decomposition of the FR fluids could contribute to acidity problems. This is not the case with Therminol 55 or 66; therefore, this bleed line should not be used during normal operation of a Therminol 55 or 66 system. This line should be valved off during operation but it could be retained as a convenient means of venting the system during initial startup after conversion. Further protection against a hot expansion tank occurence would be the re moval of any expansion tank insulation and feeder line insulation. -8- 0585973 TOWOLDMONOQ37182 Figure 4. SUGGESTED INERT GAS ARRANGEMENT FOR EXPANSION TANK 1 0585974 TOWOLDMONOQ37183 Figure 5. SUGGESTED COLD SEAL ARRANGEMENT FOR EXPANSION TANKS TOWOLDMONOQ37184 Carbonaceous deposits can also occur at the pump seal face due to leakage at high temperatures. The use of a seal flush system or a double mechanical seal is helpful in preventing excessive seal wear. Converting to Therminol 55 and 66 With fire-protection and oxidation-resistance procedures well in mind, let us turn to the matter of preparing the Therminol FR system for Therminol 55 or 66. Accumulation of debris over the years in the system could cause serious pro blems, especially to mechanical seals, rotary joints, etc. All heat transfer systems should be cleaned from time to time as a part of normal preventive maintenance. Since a fluid change is necessary at this time, it would seem practical to use the downtime to thoroughly clean the system prior to startup on a fresh charge of fluid. We strongly advise you not to simply drain and change, but to take this opportunity to clean your system. Many potential problems will be pre vented by so doing. Another reason for cleaning your system at this time is to assure complete re moval of the Therminol FR fluid. A system cleanout is the only sure way to do so. How to go about the cleanout is a matter of choice, but here are some alternatives for your consideration: A. Fluid Flush Cleaning This method is probably the fastest and most effective where heating surfaces are not heavily fouled. It also offers the \ advantage of not having to introduce foreign chemicals into the system. -9- 0585976 TOWOLDMONOQ37185 With this method, the system is drained of Therminol FR, re-filled with Therminol 55 or 66, operated for a reason able period of time, drained once again, and finally, re charged with fresh Therminol 55 or 66. Both the drained Therminol FR and the Therminol 55 or 66 . used to flush the system may then be returned to Monsanto for disposal. B. Solvent Cleaning This method is satisfactory for cleaning a slightly soiled system, but chlorinated solvents must be avoided. Typical . solvents used are acetone, benzene, and xylol (caution should be used with low flash point solvents). Do not use trichlorobenzene or perchloroethylene. (CAUTION: ALL SOLVENTS SHOULD BE COMPLETELY REMOVED FROM THE SYSTEM PRIOR TO CHARGING WITH THERMINOL 55 OR 66). Normally this is accomoplished by drying the residual with warm air or by operating the refilled Therminol system at a temperature slightly above the boiling point of the solvent until the residual is vented from the system. Some caution should be used in drying the system to prevent flashing of the solvent with resultant discharge of Therminol from the system. Both the drained Therminol FR and the flushing solvent may then be returned to Monsanto for disposal. Fluid Disposal Monsanto offers an incineration service for the disposal of PCB heat transfer fluids and the flushing fluids mentioned above. For details of this service -10- 0585977 TOWOLDMONOQ37186 and how to return fluids to Monsanto for disposal, please write: ' v Monsanto Company P.0. Box 14617 St. Louis, Missouri 63178 - ...or call (314) 694-2314 and ask for a Monsanto Heat Transfer Specialist. Handling: General Information Heat transfer fluids are intended only for indirect heating purposes. Under no circumstances should any Therminol heat transfer fluid be allowed to come in contact with or in any way contaminate food, animal feed, food products, food packaging materials, food handling equipment, pharmaceuticals or any food-related items, Therminol ,55 and Therminol 66: Safety of Handling .. According to the definitions of the U. S, Federal Hazardous Substances Label ing Act, Therminol 55 and 66 are not toxic substances since the oral and dermal lethal doses in animals are greater than 5 grams per kilogram of body weight. Additional animal studies indicate that they do not have significant skin or eye irritation potential. It is suggested however, that good industrial practice relating to the avoidance of repeated and prolonged skin contact to any industrial chemical, heat transfer fluids, or petroleum product be followed. Therminol 55 and 66 have such low vapor pressures at ambient temperature that inhalation of vapors during transfer of fluid from shipping containers to a heat transfer system presents no hazard. Vapors emitted by either fluid at elevated temperatures may be irritating as would be the case with excessively heated petroleum oils. In heat transfer installations, the fluids are used in a closed, unpressurized system free from leaks and with the expansion tank -11- 0585978 TOWOLDMONOQ37187 vent trapped so as to condense any vapors and thus prevent their escape to the work environment. Consequently, there should be little or no opportunity for workers to experience any contact or exposure. While it is believed that Therminol 55 and 66 pose no serious problems with respect to the environment, as a concerned supplier to industry, Monsanto urges the user to maintain a tight system, to correct leakage promptly, and to exercise care in the handling and disposal of this and all other such products. A tight maintenance program not only protects the environment, but keeps employes comfortable, the working area clean, and the system running smoothly. -12- 0585979 TOWOLDMONOQ37188