Document GmX3v9kmjYe3Eb24ExJmnLmgY
ArASTlr 1
PLAINTIFF'S EXHIBIT ASI-2
I
AMERICAN STANDARD
7^-
Ratings & Data of
Discontinued KEWANEE
Boilers
Volume 1
PRICE - $10.00
FORM 3149
"h *
< V' <
3 \\ 4A
v>4
TV
s
.0
3
.
x
lx 'V
v>
Vr-
\
4 V-
<T %
fm4X' 'M
\
5T,
M
tV V'k
V
V\
1
X
v
v.
X
* ft.
'V -L
vV<>J
J2^
Jl
$
n
rj
"\
*4}
A &A s>
i"
X/
p A, J'
P
\
Ov
"V
Hu
o
V Xv
AV
V.
1 : % \ *v vj
X
v: >
$\
X
j'o x A
. Vi
**v>
V
^X
X\ V
Xn -.
- Js5>
55
>
V
yv
X
o
ii i
X
A s X A
XX ai
Xs.
i
A A
r V
tK
, v>. n 'v 4; * < ; i
^ - s'
^*i
* t"
"W> "*
JAur-y *>. fits
A
--\ 0 \. -<.esU--c;\<,4 580 ^X
/
% Xy V
5C 0^
1* r . _
AV^. <y i)
vVFFOREWORD
f
/ rr r'
t This bookjet'consolidates reproductions of catalog pages on the jdldyKEWANEE BOILERS which are obsolete.
To simplify this data, only a single, page of any listed unit is included. Some will show hand fired coal ratings, some will have oil capacities. By the use of the factors which we list below, the rating for any fuel can be calculated.
REPLACEMENT SIZING
This catalog data is being sent to you to assist you in sizing replacement boilers. Selection of a boiler on the basis of the size of the existing equipment does not re lieve you of the responsibility for determining the total load to be carried by the new unit(s). Due regard must
3e given to the condition of the system and to all addi-
This listing has been compiled lo enable you to size 'tional loads added since the original installation, includ
boiler replacements. Since many1 existing installations, while originally sized for hand fired operation will now j be automatically fired, jwe recommend your calculatin; <|T1 (istedjunitston the old SBI basis as follows:
ing, but not necessarily limited to, service hot water, additional heating equipment, pipe loss, start up allow ances, etc.
(1) For hand fired coal note below.
Heating surface x(14 p^'SBI GROSS output
iFnosrqouial-rGe afese-tS(tEoDkeRr)'\v
Heating surface x 17 -- 'SBI IGROSS (output
square feet (EDR).
-----
v SIZING WITHOUT NUMBER PLATES
On many old installations identifying number plates will be missing. Some were attached to the base ashpit doors and in the process of conversion to automatic firing, the identification is lost.
Ratings so calculated are comparable in-theinwsage to
'"`'current SBI GROSS outputs.
*y'
Several reliable alternatives axe available.
Note: This does not apply to our Scotch Marine Boilers other than the original Scottie Junior riveted, HM-6 through HM-30. No other Scotch Marine Boilers have been offered by us for coal fired operation. FIRING
All of our recent catalogs'have /listed firing rates at
/150% or 141.5% of^SBI nating. On the case of such a catalog listing, the|firmg rates may be safely followed.
(1) Look for the boiler stamping as shown Appendix, Page V. This includes the boiler number and the safety valve capacity. The latter is an excellent basis for selecting a replacement size, in the same fuel
(2) Identify boiler type; up draft, downdraft, firebox, compact, Scotch Marine, horizontal return tubular, etc.
-^It is not advisable toycalculate the firing rates on our ,y (3) Check the number, diameter and length of boiler
K older boilers in the 4earie manner. Those boilers that. ^ ' y tubes, direct and return, and compare with current
q have been installed for some time, the ratings for which y-', v Bulletin 100--3-100H and/or listings of obsolete
' have been calculated as above, should have their firing' ?
J rates selected on
-frf.capacity.^Furthermore, the
units on Appendix pages I, II, III, IV.
] overall efficiency of automatic gas or oil fired boilers .4 should be assumed to be 75% (stoker fired units as '*' 65%). On this basis, the firing rate would be determined
(4) Compare size as determined #3, with dimensions of shells listed in this booklet, including the very
as follows:
\ t i^
cP
V $*
Square feet EDR (SBI) x 240 Fuel value in BTU x .75(Notea.
BTU efficiency)
--
Firing
Rate\v
iV7
important inside firebox dimensions. Only when all three, tube, outside and inside firebox dimen sions coincide, can you be sure of exact boiler number.
BTU content of fuels is listed below: Coal-Stoker Fired - 12.000 BTU/LB.
(5) Be sure the unit in question was made in Kewanee, Illinois. Some years ago, Fitzgibbons Boiler Com
11.000 BTU/LB.
pany sold a unit under the name of Kewanee
10.000 BTU/LB.
which was not ours.
Gas Oil - Light #2
Heavy #5 & #6
1,000 BTU/FT.3 140.000 BTU/GAL. 150.000 BTU/GAL.
In general, our units have four or three digit numbers. In the case of four digits, the first two identify the model eg M 8080 is a Scotch Marine boiler, 8000 series.
Note a. 65% efficiency stoker fired
The three digit numbers use the first number to identify the model eg #419 is a 400 series updraft with 4" tubes.
Rating
EXAMPLE
#419 - Heating surface 1168 FT2
iX
^1168 x 17= 19,856 FT2/EDR (SBIX'O'-^V/.$*
Y r .> Firing Rate
In both cases the last two numbers identify the size or capacity within a given model number.
A word about conversion of downdraft bituminous (smokeless) boilers. These units had a tubular water grate between the upper and lower firebox areas. The surface of these tubes is included in the cataloged heating surface When converted to gas, oil or stoker, this
S' 19,856 FT2 x 240 BTU _ 4,765,440 BTU S- \ 150,000 BTU/GAL x .75 112,500 BTU = 42.4 Gal.'
water grate need not be removed if the installer properly
sets the burner equipment so that fire will not impinge on the water grate.
INDEX
Boiler Number
Page
Brickset 0-20..........................................................................................................................................
\
Firebox 0K-20K.....................................................................................................................................
%
Brickset 104-120.....................................................................................................................................
'
Firebox 104K-120K.............................................................................................................................
4
Firebox Downdraft 307-324..................................................................................................................
5
Firebox Downdraft 376-390..................................................................................................................
6
Firebox Updraft 407--424 .....................................................................................................................
7
Firebox Updraft 480--490 .....................................................................................................................
8
Firebox Updraft 524-544 .....................................................................................................................
9
Firebox Updraft 576-590 ..................................................................................................................... 10
Firebox Updraft 832-843 ....................................................................................................................
11
Firebox Downdraft 932-943.................................................................................................................. 12
5000 Series Updraft 5133 -- 5145 Weld and Rivet...............................................................................
13
5000 Series Updraft 5076 - 5090..........................................................................................................
I4
6000 Series Downdraft 6126-6144 Weld and Rivet............................................................................. 15
6000 Series Downdraft 6077-6090 ........................................................................................................ 16
G Series Smokeless G-18-G-60............................................................................................................. 17
GD Series Smokeless GD--40-GD-400 .................................................................................................. 18
P Series Firebox P-18 - P-60...............................................................................................................
19
4000 Series 4073-4223 .......................................................................................................................... 20
Horizontal Return Tubular 150# Half or Full Front 80-200 .....................................
21
Horizontal Return Tubular 125# Half or Full Front 80-200 ............................................................. 22
Hi-Test HT-50 - HT-150...................
23
Scottie Jr. Riveted HM-6 - HM-30..................................................................................................... 24
HM Series Welded Scotch Marine HM-52 - HM-304 ..................................................................... 25-26
M 8000 Series Scotch Marine M-8173 - M-8190............................................................................. 27
Kewanee Residence Type R 740-748 .................................................................................................. 28
Kewanee Square R 83 Series 83-R1 83-R9.......................................................................................
29
Type C Electric Weld Boiler 749-770 ...............................................................................................
30
Type C Electric Weld Boiler 2773-2790 ............................................................................................. 31
Type C Hi Firebox Welded Boiler 7-L-73 - 7-L-90........................................................................ 32
Type C 7L Series 7-L-178 - 7-L-193............................................................................................... 33
APPENDIX
Tubes:* Size Length and Number, and Stamping
I Brickset, Type K, 300-400-500-800-900 Series
II 5000, 6000, G, Round R, Square R, 749-up Type C
----
III K, P, G, Scottie Jr. - 8000-300-400-500 Series Simplified Practice
1
IV Round R, Square R, 83 R, Type C, 5000, 6000 Series Simplified Practice r"
V Boiler Stamping
_)
* For current series use Bulletin 100-3-100H, P&D Book.
Or ^oflp/jce 4-tJ P /Z.A T*
^
Co:-sot/0*T,"j - (3.6. I-) sretc. Vo,Urn
itjtv --
firfeeic.J.
f \
Kewanee Boiler Brick-set for Heating
^J
t ^
^ Y Y
The Kewanee Up-Draft Boiler will burn any kind of fuel; hard, soft or lignite coal; coke, gas or oil. It will secure the maximum efficiency for an up-draft boiler; but when soft coal is used, we recommend our smokeless type of boiler, which is designed especially for burning soft coal smokelessly.
includes the fire-b. . the boiler which is surrounded by water, the tubes, and the outside surface of the cylinder or shell below the water line. Kewanee boilers are practically all heating surface.
The ratings shown below are based Qn # standard for steam of two pounds pressure at the
The heating surface of a Kewanee boiler is boiler, and for water on a mean temperature of
that portion of the boiler containing water, with 180 degrees Fahrenheit as the water leaves the
which the fire and gases cp/r>e in contact. This boiler.
* -*
'-.A5
* c-t,
\V W
0 V
r 'c ^ V
*,
Specifications
\
C \'
\
'a
CnN
*
\ ?
A
b
?
\* V
<c \
0 ?0
v\ Number of Boiler......................... \ 0 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 20
Ciptdty,Stcui...^Ar.iq.(t 4 700 900 1050 1200 1400 WOO 2000 2600 3000 3500 4000 4500 5500 6500 7500 8700 10000 11000 12000 14000
Capably, Water...
ft. 1150 1500 WOO 2000 2300 2800 3300 4300 5000 5800 6600 7400 9100 10700 12400 14400 16500 18200 19800 23100
Diameter Boiler............................in. 24 30 30 30 36 36 36 42 42 48 48 48 54 54 60 60 66 66 72 72~ Length Boiler overall...........ftlnu 6-10 6-5 7-6 8-6 7-6 9-0 10-6 10-0 11-6 10-6 12-0 13-6 13-11 16-5 15-6 18-0 16-0 IB-0 16-0 18-0
Approximate Weight, Pound*----Width of Fire-bo*........................in-
Length of Fire-box..................... in. Height of Fire-bo*...................... in.
1900
19 26 30
2400
24 26 33
2700
24 32 35
2900
24 38 35
3300
30 32 38
3700
30 38 38
4200 5400
30 36 44 44 38 41
6000
36 50 41
6700
42 44 44
7300 6000 10600 11900 14400 16000 17800 19100 21700 23500
42 42 48 48 53 53 59 59 65 65*" 50 56 56 62 62 68 62 68 68 74 44 44 49 49 54 54 59 59 64 64
He*ting Surface..................... q.'ft. $0 113 131 147 180 21$ JMJ 305 350 368 420 472 560 673 743 873 954 1080 1167 137?'
Area of Crate......................... ay ft ^3.5 4.4 5.4 6.4 6.8 8 0 ~9.3 It.t 12.6 12.9 14.7 16.5 18.8 20.8 22.9 25.1 25.5 28.0 30.8 33.5
Diameter of Breeching...............in. 10 Diameter of Stack....................... in. 10
12 12
14 12
16 14
16 14
16 16
18 16
20 18
22 20
22 20
24
n
24 22
28 26
28 26
32 30
32 30
32 32 30 30
36 34
36TM" 34
Minimum Height of Stack........ft. 35 40 40 40 40 40 45 45 45 45 50 50 50 50 55 55 60 60 60 60
Diam. of Breechinc. 2 Boiler*.jn. 16 to 20 22 22 24 24 28 32 32 32 34 36 36 40 40 40 42 44 46
Diam. of Stack, 2 Boiler* ... Jn. 16 Min. Hgt. of Stack. 2 Boiler* .. ft 40
18 45
(8 45
20 45
20 45
22 45
22 45
26 50
28 50
28 50
30 50
32 50
34
55
34 60
36 60
36 70
36 70
38 70
40 70
42 70
Sue of Steam Opening............... in. 3
Sac of Return.............................. in. ' 2
445
w 2K 3
5 3
6
6 3
6 4
6 4
6 4
6
4
8 5
8 5
6
5
8 5
8
5
8
6
8 6
8 6
8
6
She of Safety Valve................... in.
IK IK IK IK IK 2 2 2 2 2K 2K 2K 3 3 3H 3K 3K 4 4
Height of Water Line............... in. 47 52 52 52 55 55 55 58K 58K 61 61 61 66 66 75 75 80 60 85K 85K Height from Floor to Top of
Brick Work..............................in. 64 70 70 70 77 77 77 83 63 90 90 90 96 96 108 108 114 114 120 120
yx
* 4 < -J. '
7 ft / .
;
/
Kewanee Up-Draft Boilers
Portable Type K and Brick-Set
Number of Boiler. Type K.................. OK IK 2K 3K 4K_ 5K 6K 8K 9K I0K 1 IK I2K 13K 14K I5K 16K I7K I8K 19K 20K
'1''
Sq. Ft. 5(0 690 940 1240 2)380 i 1630 2410 3340 3850 4(70 4730 5290 6260 7520 8440 9910 1(070 12540 (3890 (5610 .Sq. Ft. 820 1100 1500 I960 210 2930 3660 5340 6160 6670 7570 6460310020 12030 13500 15860 17710 20060 22220 25300 Approximate Weight............... Pound* 2600 2900 3200 3500 3900 4400 4900 6300 6900 7600 8300 9000 11100 12400 15000 16600 17900 19200 21900 23700
l <) V^0
Capacity Steam. . .fcP.lK . .Sq. Ft. Cu. Ft.
Approximate Weight........... Pound*
1040 10.3 2300
1410 14.8
2650
/ .__ s
1580 1770 .2360 18.6 22.4 23.6 2900 '3130 3550
2790 28.4 3950
3230 33 1
4400
4100
43.6 5650
4680 49.8 6180
5060 51.2 6900
5740 58.9 7500
6420 66.6 8100
7600 9130 10250 12040 13450 15230 16860 19190 85.4 95.1 115.6 127.6 140.6 155.5 186.1 203.4
9900 11100 13500 15000 16250 17400 20000 21500
Sq.Ft. 61
83 93 104 139 164 190 241 275 296 338 378 447 537 603 708 791 896 992 1129<
Length of Boiler Overall.. . . Ft. In. 7-9 7-10 8-10 *-10 8-10 10-4 11-10 11-4 12-10 11-10 13-4 14-10 15-4 17-10 17-0 19-6 17-6 19-6 17-6 19-6
Minimum Height of Stack. . . . . Feet 35 35 35 35 35 35 40 40 40 40 45 45 45 45 50 50 55 55 55 55
Minimum Height of Stack.
j
Two Boilers.............................. ...Feet 40 40 40 40 40 40 40 45 45 45 45 45 50 55 55 65 65 65 65 65
Height from Moor to l op of Boiler............................................
51 59 59 59 . 65 65 65 71 71 77 77 77 63 63 93 93 99 99 105 105
Type K and Brick-aet
1
Area of Crate............................... Sq. Ft. 3.5 4.4 5.4 6.4 6.6 8.0 9.3 11.1 12.6 12.9 14.7 16.5 18.6 20.8 22.9 25.1 25.5 28.0 30.6 33.5
Height of Fire-box.....................
19 24 24 24 30 30 30 36 36 42 42 42 48 48 53 53 59 59 65 65 26 26 32 38 32 38 44 44 50 44 50 56 56. 62 62 68 62 68 68 74 30 35 35 35 38 38 38 41 41 44 44 44 49 49 54 54 59 59 64 64
24 30 30 30 36 36 36 42 42 48 48 48 54 54 60 60 66 66 72 72
Diameter of Breeching...........
10 12 14 . 16 16 18 18 20 22 22 24 24 28 28 32 32 32 32 36 36
Diameter of Stack.....................
10 12 1? 14 14 16 16 18 20 20 22 22 26 26 30 30 30 30 34 34
L>iam. of Breeching. Two boiler*. 1 n. 16 18 20 22 22 24 24 28 32 32 32 34 36 36 40 40 40 42 44 46
Diam. of Stack, Two Boiler* .Inches 16 18 18 20 20 22 22 26 28 28 30 32 34 34 36 36 36 38 40 42
Sixe of Steam Opening............ Size of Return.............................. Size of Safety Valve...............
3 445 5 6 666 6 6666 8 88888 2 2'/! 2'/i 3 3 3 3 4 4 4 4 5 5 5 5 5 6 6 6 6 1 1% IV. iv. i'/i Vi 2 2 2 2 2 Vi 2l/l 2 Vi 3 3 3'/j 3Vj 3 Vi 4 4
Height of Water-line...............
Sq. Ft. ' Approximate Weight............. Pounds
45 52 52 52 55 55 55 58H 58H 61
6
1 ~T~ 5
,4
5
6
8 4 16
sin 690 940 1740 /V380 Wjo 2410 3340 4170 4300 1900 2400 2700 2900 ^300 3700 4200 5400 6000 6700
61 61 66 66 75 75 80 80 85 M 85 M ii 12 i3 U li u 17 l& 19 20
5130 6070 7440 8770 10310 12080 12420 14670 16340 18610 7300 8000 10600 11900 14400 16000 17800 19100 21700 23500
Capacity. Steam. Oil. Ga* or Stoker.......................................... Sq.Ft.
\'v . 4*umace Volume. Oil. Oat or f.ir Stoker.......................................... .Cu. Ft. ' Approximate Weight. Oil. Ga* or
Stoker......................................... Pound*
1440 10.3 1800
1920 14.6 2200
2230 18.6 2400
2500 3060 22.4 23.6 2500 2900
3650 4250 28.4 33.1 3300 3700
5180 5950 43.6 49.6 4800 5300
6250 51.2 6000
7140 58.9 6500
8020 9520 11440 12630 14840 16210 18260 19840 26600 66.6 85.4 95.1 115.8 127.6 140.8 155.5 186.1 203.4 7100 9400 10600 12900 14400 16200 17300 19600 21300
Heating Surface.......................... .Sq.Ft, 84 M3 131 147 160 215 250 305 350 368 420 472 560 673 Minimum Height of Stack . . . Feet 35 40 40 40 40 40 45 45 45 45 50 50 50 50 Min. Hgt. of Stack. 1 boiler*.. . Keet 40 45 45 45 45 45 45 50 50 50 50 50 55 60 Height from Moor to i op of
Brick Work............................ .Inches 64 70 70 70 77 77 77 83 63 90 90 90 96 96
(feated Capacity for Water Boiler, 60% Greater than Ste>fn? MeMurtmenti Table* on neit page*
743 55 60
108
873 55 70
108
954 60 70
114
1080 1167 1329 60 60 60 70 70 70
114 120 120
Tk< Plumbing and Healing Catalog
2
> -k, r
i. fev/ ^
n^Jr
/.gx/S\>
rio Sr;/U
1.0 5 Ten A/ e'A.
/.ox ZV
2. ^ -q f ro/
//.
Kewanee Smokeless Boilers
The Kewanee Up-Draft Boiler will burn any kind of fuel: hard, efficiency for an up-draft boiler. When soft coal is to be used
soft or lignite coal; coke, gas or oil. It will secure the maximum smokelessly, we recommend our down-draft type of boiler, which is
designed especially for burning
Kewanee Smokeless Boiler with Stack Connection at Front
soft coal smokelessly.
K----------------
P Man Mote SuPPb\l
5^-Safety Vt1y
The heating surface of a Ke wanee boiler is that portion of the boiler containing water, with
which the fire and gases come in
contact. This includes the fire
box of the boiler which is sur
rounded by water, the tubes, and
the outside surface of the cylin
der or shell below the water line.
Kewanee boilers are practically
all heating surface.
"The ratings published in this
catalog are in conformity with
-at the Steel Heating Boiler Insti
tute's Code for Rating Low Pres
sure Heating Boilers." Fifteen
frost Elevation and Section Ash Ttl 14 (Through Brickwork at PP
longitudinal Section
pounds steam pressure is regular. Higher pressures are special.
Foundation p(an < XX
Number of Boiler..................................
104 105 106 10/ i U6
Capacity, Steam....................... Sq. Ft I6S0 2320 3120 3250 4260
Capacity. Water....................... Sq. Ft. 2640 3710 4990 5200 '6820
) Approximate Weight............. Pounds 4600 Diameter of Boiler.................... .Inches 36 Length of Boiler Over-all. . . . Ft. In. 8-7
5100
36 10-1
5600
36 11-7
6200
42 9-10
6800
42 11-4
Width of Fire-box..................... .Inches 30 30 30 36 36
* Length of hire-box................. .Inches 45 51 57 54 60 - t -Heating Surface...................... So. Ft. J206 243 288 297 345
""Area of Upper Crate.............. Sq. h t. 5.9
7.2 6.4
8.6 10.1
^Diameter cf Breeching........... .Inches 20 20 22 22 22
Diameter of Stack.................... .Inches 18
18 20 20 20
Minimum Height ot Stack . . . . Feet 45 45 45 50 50
Diam. of Breeching, Two Boilers In. 26 26 28 28 30 Diam. of Stick, I wo Boilers . . Inches 24 24 26 26 28 Minimum Height of Stack, Two
Boilers........................................ ... Ft 55 55 55 60 60
Size of Steam Opening............ . Inches 5 6 6 6 6 Size of Return ........................... inches 3 3 3 4 4
Size of Safety Valve................. . Inches l M IM 2 2 2
Height of Water-line............... . Inches 55 55 55 58 M 58H Height Irom Moor to lop ot
Brickwork................................. . 1 nches 77 77 77 83 S3
Capacity for Oil, Cas or Stoker --Steam, J6U0 to 24,750 sq. rt. --Water 60% Greater than Steam
10*
5020 8030
7300
42 12-10
36 66
393 1 1.4
24 22 50
32 30
Specifications
1 10 1 i 1
112 "T7T-
5250 6270 749C 879C 8400 10030 11980 14060
8500 9;oo 9800 12500
48 48 48 54 12-4 13-10 15--4 15-9
42 42 42 48 66 72 78 78
425 480 535 628 i 1.8 13.2 15.0 17.1
24 27 27 30 22 24 24 28 50 55 55 60
32 34 34 36 30 32 32 34
114
10370 16590
13900
54 18-3
48 84
741 19.1
30 28 60
38 36
11$
11750 18800
16400
60 17-10
53 90
839 21.1
34 32 60
42 38
116 -nr- 118
1362C 14900 I672C 21790 23840 26750
18000 20400 22100
60 66
66
20-4 18-4 20-4
53 59 59 % 90 96
973 1064 1194 23.3 23.5 25.9
34 36 36 32 34 34 60 70 70
42 44 45 38 40 42
i 1$
1807C 28910
23*00
72 18-4
65 96
1291 28.5
38 36 70
48 44
120 20360 32610 25600
72 20-4
65 102
31 .'3
38 36 70 50 46
60 60 60 60 70 70 70 75 75 80 60 80
6668 88 8 88 6 86 4445 55 5 56 666
2 2 2M 2M 3 3 3 3M 3H 4 4 2-2M
58 M 61
61
61
66 66
75
75 80
80 85H 85 t
83 90 90 90 96 % 108 108 114 114 120 120
Setting Measurements
Number of Boiler..................................... 104 105 106 107 108 109 1 10 111 li2 I 1 > 1 14 IT5 116 117 i 14 119 ~rar
A--Diameter of Boiler........... Inches 36 B---Length Boiler..................... Ft. In. 8-7
36 10-1
36 42 42 42 48 ! 1-7 9-10 1 1-4 12-10 12-4
48 48 54 54 13-10 15-4 15-9 18-3
60 60 66 66 72 72 17-10 20-4 18-4 20-4 18-4 20-4
C--Rear Space ......................... .Inches 17 17 17 22 22 22 22 22 22 24 24 24 24 24 24 28 28
D--Thickness Wall.................. .Inches 9 9 9 9 9 9 9 9 9 13 13 13 13 13 13 13 13
--Length Crate....................... .Inches 31 37 43 37 43 49 43 49 55 55 61 61 67 61 67 67 73
J--Width Ash-pit.................... .Inches 31 31 31 37 37 37 43 43 43 49 49 54 54 60 60 66 66
r -- 1 hickness bridge Wall. . .Inches 9 9 9 9 9 9 13 13 13 18 18 18 18 16 18 18 18
C--Crate to Tube Sheet. . . . .Inches 14 14 14 17 17 17 23 23 23 23 23 29 29 29 29 29 29
U--Header to Bridge Walt, . .Inches 7
8
9
9 10 12 10 1 1
1214 13
14
14 I5H 14
I5M 16
17
H--Height Brickwork............. Inches K--Location Steam Supply Ft. In. L--Length Over-all ............... Ft. In M---Height Water-line . . . .1nches
77 6-0 10-9 55
77 7-0 12-3 55
77 8-0 13-9 55
83 7-6 12-5 58!4
83 8-0 13-11
58!$
83 8-9 15-5 58M
90 8-10 14-11
61
90 9-8 16-5 61
90 10-4 17-11 61
96 1 1-0 18-10 66
% 11-6 21-4 66
108 ! 1-10 20-11
75
108 13-0 23-5
75
114 12-0 21-5 80
114 13-0 23-5 80
120 12-1 21-9
85 H
120 13-1 23-9 85 4
N--Height Side Flue . . . . .1nches
O--Diam. Breeching Conn . .Inches
P---Anchor Bolt Ctr Ash-pit 1nches
0--Anchor Bolt Ctr. Ash-pit inches
-Height Brick Shelf . . . .Inches
S-- J op h iue Space.................... .Inches
*T--Length Brick Shelf... .1nches
V---Length of Arch. . .
ht In.
J6 20
8 36 47
7
36 5-3
36 36 20 22
88 36 36 47 47
77 42 54 6-3 7-3
39 39 39 42 42 22 22 24 24 27
68868 42 42 42 48 48 50 50 50 53 53
7 7 768 36 48 60 54 66 7-0 7-6 8-0 6-1 8-11
42 27
8 48 53
8 80 9-9
48 30
8 54 56
8 84 10-0
48 30
8 54
56 8
102 10-6
51 34 11 60 63 10 90 10-10
51 34 11 60 63
10 ioa 12-0
58 36 11
66
66 10 90 11-0
58 36 11
66
66 10 108 12-0
63 38 11
72 69
10 64 1 l-l
63 36 11
72 69
10 102 12-1
W--Width Over-all............... Ft. In. 5-6 *Z--Width Double Setting Ft. In. 10-3
5-6 5-6 10-3 10-3
6-0 6-0 6-0 11-3 11-3 1 1-3
6-6 12-3
6-6 12-3
6-6 12-3
7-8 14-3
7-8 14-3
8-2 15-3
8-2 15-3
8-8 16-3
8-8 16-3
9-2 17-3
9-2 17-3
Number Common Brick.. Number hire brick ....
'Common Brick lor iwo Boilers,
2200 85
3900
2350 85
4100
2450 85
4300
2600 100
4500
2850
too
4950
3100 100
5350
3700 130
6500
4000
130 7000
4300 130
7550
6000 155
10500
6600 155
11500
7350 215
12750
7900 7800 215 250
13700 13200
6300 250
14200
8700 310
15000
9300 310
16000
Foundation not included Key letters N and V apply c nly to boiler settings nth breeching connection at front at shown above. Key letters R and T apply only to boiler settings with breeching connection at rear; and letter Z applies only to Double settings both, as orf Brickset Up* Draft Boiler diagram on preceding page.
Tf* Plumbing and Htaiing Catalog
3
Kewanee Smokeless Portable Type K Boilers
Ktwiite* Smoktleii Portable Typo K Boiler. I04K-112K Have C. X. Baeo.
There is a Kewanee Boiler the right size for every building from the 2-apartment building to the largest hotel, factory, or business block. Portable Type K Boiler for smaller buildings is constructed along the same lines that the larger Kewanee Boilers are built. It is made in both the smokeless and up-draft types. The Smokeless boiler in this type K has a rated ca pacity of from 1500 to 15200 square feet in steam, and from 2450 to 25000 square feet in water.
Specifications
Number of Boiler................................................
104 K 105 K 106 K 107 S 108 X 109 K noK 111 K 112K USX 114K nsx I16K 117s'll6K 11Sk||30K
Capacity. Btcam................................................. ... .eq. ft. Capacity. Water.................................................
2450
3100
2200 2500 3600 4100
2900 4800
3400 5000
3800 6300
4400 7400
5200 6200 7100 8100 9500 1090012300 1330015200 8600 10100 11800 13300 15700 1800020400 2190025000
Approximate Weight, Pound*........................
6000 5600 6100 6900 7500 8100 9200 9900 10600 13600 14000 16500 18100 2050022200 24000[36000
Length Boiler Oversell......................................
so 86 0-11 11-5
66 42 12-11 11-2
42 12-8
42 14-2
48 13-8
48 15-2
48 16-8
54 17-1
54 19-7
60 19-4
60 ss I OS 72 72 21-10 19-1021-10 19-1021-10
Length of Fire boa............................................
.. so 30 30 36 36 36 42 42 42 48 48 53 S3 59 59 65 65
45 61 67 54 60 66 66 72 78 78 84 90
90 96 96 102
157 165 220 234 271 308 338 381 425 500 590 677 787 879 967 1090 1230 Area of Upper Crate......................................... . . -eQ. ft. 5.9 7.2 8.4 8.6 10.1 11.4 11.8 13.2 15.0 17.1 19.1 21.1 23.3 23.S 26.9 28.5 31.3
Minimum Height of Stack..............................
20 20 22 22 22 24 24 27 27 30 30 34 34 36' 1 36 38 38
18 40
16 40
20 40
20 45
20 46
22 46
22 45
60
50
28 65
55
65
65
36 65 | 65 65 65
20 24
26 24
28 28 26 26
30 28
32 32 34 30
34 36 38 34 3o
42
42
44 | 43 48 50 46
Minimum Height of Stack. Two Boilen... ............. ft. 50 50 60 55 56 55 53 56
63 65
flise of Retura..................................................... Biee of Safety Valve..........................................
66 S- 3
6 3
6 4
6 4
6
6
6
8 5
8 5
8 6
8 6
8 6
8I8 8 8 6j6 6 6
Two-
1H 1M 2 2 2 2 2
2H 8
8
3
3M 3H; 4
4
2H
Height from Floor to Top of Boiler. ......
55 56 65 58H &8H 53H 61 61 61 66 66 75 75 so | so 65K 85 H 65 65 65 71 71 71 77 77 77 83 83 93 93 99 99 105 105
I
<
Section Kewanee Smokeless Boiler showing Portable Type K Setting Plan and Founda tion.
Boilers No. 104K-112K.
i
4
Section Kewanee Smokeless Portable Boiler
Nos. 307-309 have bell top and cast iron base as shown above.
Nos. 310-314 have bell top and brick base.
Nos. 315-324 with brick base as shown on opposite pafe.
Kewanee Smokeless Portable Boiler
The Kewanee Smokeless Portable firebox heating boiler elimi nates brick setting. Built of riveted steel, it goes into the building in one piece. Any kind of coal is burnt smokelessly and the ex treme heat of burning oil is developed and absorbed with high efficiency by the large water content kept in rapid circulation by the water grate.
Boiler No. 314 (and smaller) constructed with enlarged cylinder. Iron ash pit furnished with Boiler No. 309 (and smaller). Boiler No. 310 (and larger) set on brick foundation. Manholes are pro vided on 54-inch boilers and larger.
Section Kewanee Smokeless Boiler
/
Showing Portable Type Setting Plan
Boilers Nos. 307-314
Note--Boilers Nos. 310, 311, 312, 313 and 314 are con structed with bell top as shown above, but are set on brick foundation instead of cast iron base as shown. Manhole is located in rear head.
Specification*
Number of Boiler. . .
307
Capacity, Steam.. .. Sq. Ft. 3390 Capacity, Water. . .. Sq. Ft. 5420
Oil. Gas or Stoker: Capacity. Steam.. Sq. Ft. Furnace Volume. . Cu. Ft. Approx. Weight.. . Found*
5050 51 .a 7300
Approximate Weight. Pounds 7500 Diameter of Boiler... .Inches 45 Lgth. Boiler Overall. Ft. In. 9-1
Width of Fire-box , .. . Inches 36 Length of hire-box.. . .Inches 54
Heating Surface......... Sq. Ft. Area of Upper Grate. Sq. Ft. Diam. of Breeching. , . [nches Diameter of Stack. . . . Inches Min. Height of Stack . . . Feet
297 5.8 22 20 50
Diameter of Breeching. Two Boilers................I nches
Dismcter of Stsck, Two Boilers............. .Inches
Minimum Height of Stsck.Two Boilers . . . Feet
30 28 60
Sixe of Stesm Opening, inches Size of Keturn............. Size of Safety Valve. . Inches
6 4
2
Height of Water-line . Inches Height Moor to [op
of Shell...................... Distance Required to
Open Rear Flue Doors. In.
71 84 26
308
4260 6820
5990 58.1 8000
8600 48 10-5
36 60
352 10. 1 22 20
55
30
28
65
6 4 2
71
84
26
309
5020 8030
6650 64.3 8600
9300 48 11-5
36 66
391 11.4 22 20 55
30
28
65
6 4 2
71
84
26
310
6100 9760
311 312 313 314 315 316 317 318 319 320 321 322 323 324 6950 7650 8290 9000 J0I00 10820 12770 M740 16860 18420 20410 21690 29040 36810 11120 12240 13260 14400 16160 17310 20430 23580 26980 29470 32660 34700 46460 56900
7580 82.1 9600
8430 69.4
10200
9290
96.9 I09OC
10070 114.9 13300
10920 124.4 14000
12260 152. 1
15500
13130 164.0 (6200
15500 17900 20460 22360 24800 26350 3S300 44700 181.0 193.9 220.5 231.2 256.0 272.5 367.6 388.9 19300 2(100 23100 24400 26600 27800 34300 40000
10400 54 10-11
moo 54
1 l-l 1
11900 54
12-11
14500 60 12-11
15300 60 13-11
16900 60
15-3
17600 60 16-3
20900 22900 66 66 15-9 17-9
25000 26500 28800 30000 37000 72 72 7tt 78 64
16-7 17-11 17-10 18-10 20-1
43000 64
24-1
42 42 42 48 48 53 53 59 59 65 65 71 71 77 77 72 78 84 78 64 90 96 90 96 96 102 102 108 114 120
446 12.9 24 22
55
496 14.7 24 22 55
546 16.5 24 22 60
592 17. 1 26 24 60
643 18.5 26 24 60
721 20.0
28 26 65
773 21.4
28 26 65
912 23.5
30 28 65
1053 25.9
32 30 70
1204 28.5
34 32 70
1316 29.9
34 32 70
1458
32.6 36 34 80
1549 34.6
36 34 90
2074 41.7
40 38 90
2629
44.6 42 40
100
34
31
65
6 4 2M 76 89
28
34
31
65
6 4 2M 76 89
28
34
31
70
6 4 2H
76 89
28
38
34
70 8 5 3
83
98
32
38 40 40 44 46 50 50 52 52 56 56
34 36 36 40 42 46 46 48 48 54 54
70 75 75 75 60 80 80 90 100 100 110 8 8 a 8 6 8 8 6 6 10 10 5 5 5 66666 666 3 3 3M 3M 4 4 4 2-2 H 2-3 2-3 2-3H
83 87 87 90 90 96 % 97 97 105 105
98 101 101 107 107 113 113 115 115 121 121
32 32 32 35 35 37 37 40 40 43 43
Rated Capacity for Water Boiler, 60% Greater than Steam.
Tkt Plumkint srtJ Htatinj Catalog
5
KE.WANEE. Down-Draft Firebox Boiler "300" Series For Oil, Gas or Stoker
All the extreme heat of burning oil is developed and absorbed in *'300" Series. Even heaviest load ings are carried with a steady water line.
KK --r
,y. ............
Footings may be required under base corner posts de pending on soil conditions.
Steam Supply and Safety JJ Valve located nearer front on
376-7-8-9 and 360.
Equipment: Steel base assembled with four cost iron copper posts, front end rear panels have 85* x 115** opening and cover plate: hackstand except 3/6-379; fire, grate and flue doors.
Also flue and tube cleaners with handles, socket wrench.
Manhole furnished on boiler numbers 380 and larger.
Trimmings for Steam only: Safety valve, steam gauge with syphon and cock, water column with water gauge, glass and cocks.
For Cuf-aioay Vieut "300" Series OH or
Gas, see page 24.
Note I. For one burner only, locate on center line of boiler and use single hearth plan instead of double.
Note 2. Steel plate with dampers, or for special burner mountings, also fire brick lining and hearth angles, not furnished by Kewanee Boiler Corporation.
Note 3. This dimension 1 on boiler numbers 376-381 inclusive.
Note 4. Average Firebox Height is computed by dividing the firebox volume by the plan area. On stoker fired boilers 365 to 390 additional furnace height and volume for S.H.B.I. standard may be provided in base. Or extended water leg may be ordered, and two firedoors.
Boiler Number.....................................................
Rating--Steam Radiation............. Sq. Ft. Water Radiation............. Sq. Ft. Btu. per Hour.................... 1000s
Heating Surface (SHBI min.).. . -Sq. Ft. Furnace Volume (SHBI min.).. .Cu. Ft.
Net Furnace Volume. Oil-Gas.. . Cu.Ft. Firebox Vol. Above Mud Ring..Cu. Ft. Average Firebox Height (See Note 4) In.
Specifications and Setting Measurements
3* Tubes
376
4230 6600 1020
250 30.4
56.3 49.1 37.6
377
4860 7770 1166
286 34.8
56.3 50.7 37.6
378
5470 8750 1313
322 39.1
69.6 60.1 39.3
3)9
6080 9720 1459
358 43.5
72.2 62. 1 39.3
380
7290 11660
1750
429 52.1
92. 1 79.5 44.4
361
8500 13600 2040
500 60.6
104.5 89.4 44.4
382
10330 16520
2479
608 73.8
119 6 97.0 43.8
m
12150 19440 2916
715 86.8
137.5 110.4 43.8
384
15160 24280
3643
893 108.5
162.2 130.9
46.6
Plan Area................................................. Sq. Ft.
Breeching Diameter..................................... In. Stack Diameter...............................................In. Stack Height..................................................Ft.
Breeching Diameter. Two Boilers ... InStack Diameter. Two Boilers............... InStack Height. Two Boilers.....................Ft.
Steam Supply Size........................................In. Return Sixe.......................................................jn. Safety Valve Size.......................................... in.
Shipping Weight......................................... Lb.
B--Boiler Length.................................Ft. In. C--Boiler Height Overall....................... In. U--Water Line..............................................In.
E--Water Column Height...................... In. F--Steam Supply Height. . .._............. In. G-- Breeching Connection Height. . .In. H---Rear Stand Height..............................In. J--Steam Supply Location............Ft. In.
K--Safety Valve Location.....................In.
15.7
19 17 45
25 23 55
6 3 2
6200
4i 8-3
80 70
68 62 70 38 1-10
16
N--Return Height...................................... In.
O--Firebox Width........................................In. P--Firebox Length.......................................In. R--Firebox Height.......................................In.
T Baae Width...............................................In. U---Base Length.............................................In. V--Base Height.............................................In.
W--Breeching Connection Length... In. X-- Breeching Connection Width... . In. Y--Breeching Connection Location.. In. Z--Rear Door Clearance.........................In.
AA--Furnace Length................................In. BB--Furnace Width................................. In.
19
36 62 4IH
7H 7IH
14
32 9
M
53 24
DD--Bolt Centers in Plate................... In. 37H EE--Bolt Centers in Plate........ In.
FF--Pit Depth............... ..........................In.
HH--Total Area Ports or Openings
II---Foundation Width............................ In. rCK--Foundation Length....................... In. Size o! Dampered Openings..................In.
'Outside Surface to Cover............. Sq. Ft.
64 54 725*
6x11 375 110
16.2 20 16 50 26 24 60 6 3 2
6900 42
9-3 60 70 68 82 70 38
2-0 16
19 36 64 413*
47M 73M
14 32
9 M
55 24
37H
73 54 74 H 6x12 390 120
18.4 18.9 21 .5
21 22 23 19 20 21
45 50 45
27 26 30 25 26 28 55 60 55
666 334 2 25* 25*
7400 ' 8000 | 9100
48
6-75* 66 73
48 54
9-5 H-2M 86 94 73 78
71 68
745* 38
1-10
71 88 745* 36 2-0
76 96 81 40 2-0
16 16 16
i9
42 62 44
5M
14 34 !1 75* 48 53 30
43H
\9
42 64 44
535* 74 14
34 11 75* 48
55 30
43 M 4a 9
1955 48 64 49
5,n
14
40 12 8 30
55 36 85* 495* 4% 10 44
63 60 73
6x14 410 130
92 60 75
6x16 425 140
110
7x16 450 165
24.2
24 22 55
31 29 65
8 4 25* 10100
54 12-11
94 78
76 96 81 40 9-8
15
I9J-S 48 72 49
"8
14
40 12 8 30
63 36 8M 495* 4k 10 57
127 651
7x18 460 210
26.6
26 24 50
34 32 60
8 4 3
12500
60 12-85*
101 65
63 103 86
41 9-8
14
30.3
28 26 60
36 34 70
8 4 3
14100
60 14-9
101 65
63 103
86 41 10-6
15
22H
53 72 49
66 83 17
44 14
9 33
63 42 95* 555* *s
53 82 49
66 93 17
44 14 9 33
73 42 9 5* 555* Yj
33.7
30 28 60
40 37 70
8 4 2-2
16500
66 14-11
107 885*
865* 109 89 41
10-8
15 12 22H
59 82 52
72 93 17
51 15 95* 36
73 48 11 615*
54 66 69
155 705*
64
7x22 575 220
182 705*
94
7x26 625 255
230 765*
94
2-7xi6 660 280
'Front smokebox and front head below smokebox NOT included.
xs
385 366
18220 29150
4373
21250 34000
5100
1072 130.2
1250 151.8
170.7 137.2 46.6
5 151 .9
35.3
198.2 160.2
49.4
5 176.4
38.9
31 33 29 31 70 70
41 44 38 4! 80 60
8 4 2-25*
16900
6 4 2-25*
21200
66 17-4
107
885*
72 16-5
113
945*
865* 109 89 41
11-6
21 12 225*
59 86 52
9i>n
96 41 11-6
18 12 225*
65 86 545*
72 76 97 97 17 17
51 54 15 19
95* "8 36
77 77
48 54
11
M615*
J*IBff
94 82
M273
2-8x17
680 320
320 82 98
2-8x20 715 330
387
24290 38860 . 5830
1429 173.5
228.3 163.2 49.5
7 209.2
44.5
35 33 70
47 44 60
8 4 2-25*
23200
78 17-05*
115 95
93 117 97 37 11-8
21 12 225*
71 90 55
64 ,0I8
60 18 11 42
61 60 14
*8735* 62
388
30360 48570
7286
1786 216.9
760.8 207.8
49.5 12
258.2 50.4
39 36 85
50 47 95
10 6 2-25*
27500
78 20-75*
115 95
93 117 97 37 13-4
28 12 2355
71 102 55
84
60 16 II 42
93 60 14
58735* 96
389
36430 58280
8743
2143 260.3
304.4 231.9
51.0 15
300.2 54.6
41 38 85
54 50 95
10 6 2-3
31500
64 19-II
125 I07>*
10554 1275*
109 41
13-2
26 12 275*
77 102
57
90M II3M
21
64 22 13 45
93 66 15 795* 7;i
96
390
42500 66000 10200
2500 303.6
323.3 245.5
51.0 20
341.9 57.8
43 40 100
56 52 110
10 6
2-3
35200
84 22-8
125 1075*
1055* 1275*
109 41 14-0
36 12 275*
77 106 57
90M ,,98
64 22 13 45
99 66 15
7 8795* 114
365 66
1025*
2-9x20 780 360
455 86
1145*
2-9x25 635 435
545 94
1145*
640 94
1205*
2-10x27 2-10x32
990
1020
450
510
Kswerttt Csfsls| Ns. 90 k.
6
r
Section Kewanee Up-Draft Portable Boiler
Noa. 407-409 have bell top and cast iron base as shown above.
Nos. 410-414 have bell top with brick base.
Nos. 41S-424 have brick base, as shown on opposite pa^e.
Kewanee Up-Draft Portable Boiler
Kewanee Up-Draft Portable firebox heating boilers need no brick setting and go into the building in one piece. They burn any kind of fuel. Every joint and seam is firmly riveted at the factory. Sufficient handholes are provided for cleaning purposes, and in portable boilefs 54 inches and larger, manholes are included.
Boiler No. 414 (and smaller) is made with enlarged cylinder as shown. Iron ash pits, as illustrated furnished with No. 409 and smaller. No. 410 (and larger) set on brick foundation. No. 415 and larger made with firebox same width as cylinder.
SupporUSf Strip
Section Kewanee Boiler--Showing Portable Type Setting Plan Boilers No. 407-414
Note--Boilers Nos. 410, 411, 412, 413 and 414 are constructed with bell top as illustrated above but are set on brick base instead of cast iron ash-pit. In Nos. 410 and 411 the manhole is located in rear head; in 412 and larger it is in cylinder.
Specifications
fnnJllwn l*taa *l-\\
Number of Boiler................................... 407 406 409 410 411
413 414 415 416 417 418
Capacity. Steam .^V. 4 rVC"t -'Sq. Ft. 2550 3340 4170 4300 5130 Q>qiq) 7440 6760 6700 10310 12420 14560 Capacity. Water.................... .Sq. Ft. 4060 5340 6670 6660 8210 Vto 11900 14020 13920 16500 19870 23300
<20
421
422 423
424
16240 21200 23950 30930 33980 29*80 33920 38320 49490 54370
Oil. Gas or Stoker: Capacity Steam............... Sq. Ft. Furnace Volume............. Cu. Ft. Approximate Weight. . . Rounds
4730 5270 6340 7040 7900 35.V 42.3 46.6 50.3 57.9 6400 6600 7600 6300 9000
8760 65.3 9700
9600 84.2 12000
10640 93.9
12800
11480 96.1
14600
13220 107.1
15900
15780 127.4 18600
4^856 17660
140.5 T59.8 20200 22000
22150 174.6 23600
25730 193.3 25800
29080 209.9 28600
37500 267.9 34300
40460 269. 1
37100
Approximate Weight.......... Pounds 6900 7400 8300 9000 9800 10600 13200 14100 15900 17300 20400 22000 24000 25700 26000 31000 37000 40000 Diameter of Boiler.............. . Inches 46 46 48 54 54 54 60 60 60 60 66 66 72 72 78 78 64 64 Length ot Boiler.................... Ft. In. 8-7 9-6 11-1 10-0 11-1 12-1 12-5 13-7 14-4 16-2 15-9 17-4 15-11 17-6 17-11 19-11 20-1 22-1
Width of Fire-box............... . Inches 36 36 36 42 42 42 48 48 53 53 59 59 65 65 71 71 77 77
Length ol hire-box..............
36 44 50 44 50 56 56 62 56 62 62 68 68 74 74 80 80 86
Height of hire-box..............
4IM 4IH 4IH 44 44 44 49 49 49 49 52 52 54M 54M 55 55 58 58
Heating Surface..................... .Sq. Ft. 278 310 373 416 465 515 565 626 676 778 929 1040
1303 1514 1711 2209 2427
Area of Crate.......................... .Sq. Ft. 9.6 II.1 12.6 12.9 14.7 16.5 18.6 20.6 20.7 22.9 25.5 28.0
33.5 36.6 39.6 42.9 46. 1
Diameter of Breeching. . .
22 22 22 24 24 24 26 26 28 28 30 32 34 34 36 36 40 42
Diameter ol Mack...............
20 20 20 22 22 22 24 24 26 26 28 30 32 32 34 34 38 40
Minimum Height of Stack ... Feet 50 50 55 55 55 60 60 60 65 65 65 70 70 70 80 90 90 100
Diameter of Breeching. Two
Boilers...................................
30 30 30 34 34 34 38 38 40 40 44 46 50 50 52 52 56 56
Diam. ol Mack. 1 wo Boilers. Inches 26 26 26 31 31 31 34 34 36 36 40 42 46 46 48 48 54 5< Minimum Height ol Mack
1 wo Boilers......................... . . . Feet 60 60 65 65 65 70 70 70 75 75 75 60 80 80 90 100 100 M0
Size of Steam Opening. . .
6 6 6 6 6 6 6 8 6 6 6 8 6 6 8 6 10 10
Size of Return.......................
4 4 444 4 5 5 5 5 6 6 6 6 6 6 6 6
r Size ol Safety Valve...........
2 2 2 2 2H 2M 2M 3 3 3 3 H 3J6 4 4 2-2M 2-3 2-3 2-3
Height of Water Line. . . .
71 71 71 76 76 76 83 63 87 87 90 90 96 96 97 97 105 105
Height hloor to i op of Shell. inches 84 84 64 89 8V 89 98 98 101 101 107 107 113 113 115 115 121 121
Distance Required to Open
Rear hlue Doors.............
26 26 26 28 28 28 32 32 32 32 35 35 37 37 40 40 43 43
Rated Capacity for Water Boiler, 60% Creater than Steam.
Th< Plumbing Hitting Cclolcg
4 ,^ 1
7
Kewanee. Up-draft Firebox Boiler "400" Series For Oil, Gas or Stoker
The use of Kewanee Boilers for burning oil has been increasing for years. Particularly in localities oil comes from. And wherever there is most experience with oil fuel, the good Kewanee steaming qualities are appreciated.
Equipment--Steel btM assembled with
four cast iron corner posts, front and rear
FOUNDATION AND HEARTH PLAN
panels have
opening and covet
plate; hackstand; fire and flue doors; flue cleaner and handle. Manhole furnished on all sizes.
For Cut-away View "400" Series Oil-Cae, tea page 24. And for Stoker, Similar to page 2.
Trimmings for Steam Only--Safety valve,
steam gauge with syphon and cock, water column with water gauge, glass and cocks.
Note I. For one burner only, locate on center line of boiler and use single hearth plan instead of double.
Note 2. Steel plate with dampers, or for special burner mountings, also fire brick lining and hearts angles, not furnished by Kewanee Boiler Corporation.
Note 3. This dimension 1 %/i9 on No. 460 and 461.
Note 4. Average Firebox Height is computed by dividing the firebox volume by the plan area. On stoker fired boilers 46$ to 490 additional furnace height and volume for S.H.B.I. standard may be provided in base. Or extended water leg may be ordered, and two firedoors.
Specifications and Setting Measurements
Boiler Number.........................................................................................
...Sq. Ft. .. .Sq. Ft. Btu. per Hour.............................................. ... 1000 s
...Sq. Ft. Furnace Volume (SHBI min.)............................... . .Cu. Ft.
Average Firebox Height (See Note 4)..............
. Cu. Ft. . .Cu. Ft.
460
7290 11660
1750
429 52.1
70.0 62.1 44.4
Plan Area............................................................................. . ..Sq. Ft.
Stack Height................................................................... ............ Ft. Breeching Diameter, Two Boilers.......................
Stack Height. Two Boilers. .................................... ............ Ft. Steam Supply Size........................................................
Safety Valve Size........................................................... Shipping Weight............................................................... ............ Lb.
...Ft. In.
D--Water Line..................................................................
G--Breeching Connection Height.........................
3 --Steam Supply Location...................................... ...Ft. In.
K--Safety Valve Location.......................................
N--Return Height........................................................
R--Firebox Height.......................................................
T--Base Width............................................................... V--Base Height............................................................. W--Breeching Connection Length........................ X--breeching Connection Width............................. Y--Breeching Connection Location .................. 2.--Rear Door Clearance........................................... AA---Furnace Length.................................................. BB--Furnace Width................................................... CC--Burners Location.............................................. DD--Bolt Centers in Plate..................................... EE--Bolt Centers in Plate..................................... FF-- Pit Depth................................................................ CC--Hear Dtand Location...................................... HH--Total Area Ports or Openings.................... JJ--Foundation Width..............................................
KK--Foundation Length.........................................
Size of Dampered Opening......................................... Number of Fire Brick.................................................. "Outside Surface to Cover.........................................
16. S
23 21 4$
30 26 55
6 4 255
9300
54 11-5
94 76
76 96 61 40 6-0
15
i9 li
46 50 49
60 5955
14
40 12 6 30
41 36 8 55 4955 *yiS.
64 HO 6555 61
7zl6 395 165
461
6500 13600 2040
500 -60.6
79 4 69.6 44.4
18.6
24 22 55
31 29 65
6 4 2M 10400
54 13-155
94 76
76 96 61 40 9-0
15
I9H 46 56 49
66 5955
14
40 12
6 30
47 36 855 4955
10 76 127 65 55 6/
7x16 420 210
462
10330 16520
2479
606 73.8
119.6 97.0 43.8
26.6
26 24 50
34 32 60
8 4 3
12200
60 13-455
101 85
83 103 86
41
to-o
15
22 55
53 72 49
83 66 17
44 14
9 33
63 42 9 55 5555 5H 10 63 155 7055 84
7,22 575 235
483
12150 19440 2916
715 86.8
137.5 110.4 43.8
30.3
28 26 60
36 34 70
8 4 3
13600
60 15-555
101 85
63 103 86 41 10-9
16
2255
53 82 49
93 66 17
44 14 9 33
73 42 955 5555 55<
to
76 182 7055 94
7,26 625 275
484
15180 24280
3643
893 106.5
162.2 130.9 46.6
33.7
30 26 60
40 37 70
6 4 2-2
15800
66 15-655
107 8855
8655 109 89 41
U-0
18 12 2255
59 62 52
93 72 17
51 15 955 36
73 46 n 6155 iH 10 78 230 7655 94
2-7.16 660 290
485
18220 29150
4373
1072 130.2
170.7 137.2
46.6 5
151.9 35.3
31 29 70
41 38 80
6 4 2-255
18100
66 18-055
107 8855
8655 109 89 41
11-6
21 12 2255
59 86 52
97 72 17
51 15 955 36
77 46 tl 6155 5 55 II 86 273 7655 98
2-8x17 680 335
486
21250 34000
5100
1250 151.8
198.2 160.2 49.4
5 176.4
38.9
33 31 70
44 41 80
8 4 2-255
20300
72 17-0
113 9455
9255 115 96 41
U-0
16 12 22 55
65 86 5455
97 76 17
54 19 M55 39
77 54 1255 6755 i'4 1?
92 320
82 96
2-8,20 715 345
Front smokebox and front head below srookebox NOT included.
487
24290 38860
5830
1429 173.5
228.3 163.2 49.5
7 209.2
44.5
35 33 70
47 44 80
6 4 2-255
22300
78 17-755
115 95
93 117 97
37 12-0
21 12 2255
71 90 55
10155 84 17
60 18 M 42
81 60 14 7355 5!'4 12 92 365 88 10255
2-9x20 780 375
HI o*
488
30360 46570
7286
1786
260.6 207.8
49.5 12
256.2 50.4
39 36 85
50 47 95
10 6 2-255
26400
78 21-355
115 95
93 117 97 37 13-9
26 12 2355
71 102
55
11355 64 17
60 18 11 42
93 60 14 7355 555 12 106 455 88 11455
2-9x25 635 450
489
36430 38280
6743
2143 260.3
304.4 231.9
51.0
300.2 54.6
41 36 65
54 50 95
10 6 2-3
30200
64 20-7
I2S 10755
10555 12755
109 41 13-4
26 12 2755
77 102
57
11355 9055
21
64 22 13 45
93 66 15 7955 IX(i
96 54$
94 11455
2-10,27 990 465
490
42500 66000 10200
2500 303.6
323.3 245.5
51.0 20
341.9 57.6
43 40 100
56 52 110
10 6 2-3
33800
84 23-4
125 10755
10555 12755
109 41 14-0
42 12 2755
77 108
57
11955 9055
21
64 22 13 45
99 66 15 7955 7X 13 120 640 94 12055
2-10,32 1020 520
Ketaene* Ceielog Ne. tO A.
8
Kewanee Up-Draft
Portable Boiler
The high-class workman ship on Kewanee Boilers is proverbial in the Trade and in the Architectural profes sion This "500" series reflects the best Kewanee practice based on generations of continuous experience.
*500" Sri(i Boiler with Typical Stoker Attachment
y
-/ /2C;
Setting Plan and Foundation
In the "500" series Kewanee Steel-Riveted Boilers the grate area and firebox are enlarged somewhat and a greater number of return tubes is provided.
There is a corresponding increase in heating surface, steam space, disengaging area, furnace volume and water content, all in the correct ratio and proportionate to the requirements for definite service condition.
Specifications and Setting Measurements
524 526 528 530 532
Capacity, Steam. .^.T. Capacity, Water.................................
Sq. Ft. Sq. Ft.
7060 11300
8770 | 10160 14030 | 16260
10310 16500
13720 21950
Capacity. Steam,Oil. Caa or Stoker. .Sq. Ft. FurnaceVolume.Oil, Caa or Stoker . . Cu. Ft. Approx.Weight, Oil. Caa or Stoker ,. Pound*
10110 72.2
10150
11390 93. 1 11250
12920 102.9 12100
14650 106.4 13500
16660 128.5 14900
Heating Surface........................................... Sq. Ft.
Area of Grate................................................ Sq. Ft.
Height of Firebox.........................................Inches
(diameter of Breeching....................
Inchea
Diameter of Stack.......................................... jnchea
Minimum Heiarht of Stack
Diameter of Breeching, Two Boilera. . Inchea
Diameter of Stack, Two Boilera
Inches
Min. Height of Stack, Two Boilera. . . . Feet
Size of Steam Opening................................Inchea Size of Return ........................................... Inchea
Size of Safety Valve................................. Inchea Diara. and Length Direct Tubea .... Inchea
Diam. and Length Return Tubea. . . . Inchea Dia. Required to Open Flue Doora. . . Inchea Approximate Weight.................................. Pound*
A--Diameter of Boiler............................... Inchea B--Length of Boiler.....................................Ft. In. C--Length of Crate.....................................Inchea D--Length of Aah-pit............................. Inchea E--Width of Aah-pit............................ inches
F--Ash-pit Wall to Pier .......................Ft. In. G---Height of Breeching Connection.. Inches H--Height of Boiler.................................. Inches
J--Location of Steam Supply............... Ft. In. K--Location of Safety Valve................. Inches L--Height of Water-line............................inches O---Height of Water Column...................inches
P--Height of Steam Supply.....................Inches Q-1 Height of Return...................................Inches K--Width of Breeching Connection.. Inches S-- Length of Breeching Connection. Inches T--Ctr. to Ctr. Bolts in Aah-pit Front In.
W--Boiler to Center of Breeching . . . Inches Number of Common Brick......................... Outaide Surface to Cover....................Sq. Ft.
600 18.2 44
24 22 60 34 30 70
6 4
2H 3x78 3x143
28 11160
54 13-5
62 66 42 6-0 60 89
8-6 16 76 73M 90 19 10 42 48 8
540 185
67020.8
49
26 24 65 38 34 73
8 5 3 4x65 3x130 32 12560
60 12-5
62 66 48 4--8 88 98
8-8 16 83 81 99 20
12M 46 54
Wa
560 190
760 22.7
49
26 24 70 38 34 60
6 5 3 4x73 3x144 32 13550
6013-7-
68 72 485-4 88 98
9-2 18 63 61 99 20
12M 46 54
<*Va
590 220
862 22.9
49
28 26 60 40 36 90
8 6 3 4x87 3x153 32 15000
60 14-4 62 66
53 6-6
90 101
8-11 21 87 84
103 23 12H 46 60
710 250
980 27.2
49
26 26 80 40 36 90
6 6
3M 4x97 3x175
32 16640
60 16-2
74 78 53 7-0 90 101
10-5 23 67 84 103 23 I2M 46 60
770 280
*Found,tion, not included. Rated Capacity for Water Boiler, 60% Creater than Steam.
Tkt Plumbing *nd Htatlng C*tleg Copyright June. 1935. Printed in U. S A.
I 1935
534
16380 26210
19890 152.9 18100
1170 30.5
52
30 28 80 44 40 90
8 6 4 4x90 3x168 35 20040
66 15-9
74 78 59 6-6 93 107
10-4 26 90 87M 109 23 15 50 66 I0H 790 290
536
18340 29340
22270 165.7 19300
1310 32.6
52
32 30 90 46 42 too
8 6 4 4x103 3x167 35 21500
66 17-4
60 64 59 7-6 93 107
11-2 34 90 87H 109 23 15 50 66 iom 820 310
538
19460 31140
23630 188.4 20800
1390 36.1
54M
34 32 60 50 46 90
6 6 2-2 M 4x64 3x168 37 23250
72 15-11
80 64 65 6-0 100 113
10-7 16 96 93 X
115 23 17 54 72 MM
850 315
540
21840 34940
26520 203.0 22300
1560 36.6
54M
34 32 95 50 46 105
10 6 2-3 4x97 3x187 37 24870
72 *7-6 86 90 65 7-0 100 113
11-9 16 96 93H
115 23 17 54 72 MM
880 345
542
25540 40860
31010 239.9 24200
1624 39.5
55
36 34 85 52 48 95
10 6 2-3 4x102 3x186 40 26640
78 17-5
80 64 71 7-10 101 115
11-3 31 97 94 117 23 17 60 76 HH 865 365
544
28880 46210
35070 259.0 26300
2063 42.5 55
36 34 95 52 48 105
10 6 2-3 4x119 3x209 40 28870
78 19-4
86 90 71 9-0 101 115
10-11 46 97 94 117 23 17 60 78 1IH
930 425
9
KE.WANEE. Up-Draft Firebox Boiler
"500" Series For Coal
The high-class workman ship on Kewanee Boilers is proverbial in the Trade and in the Architectural profes sion. This "500" series re flects the best Kewanee prac tice based on generations of continuous experience.
*'500`* Series Riveted Up-Dreft Firebox Boiler With Two-Pess Three Inch Tubes
_______W---------
<
II \
V
10
"500" series conforms to the A.S.M.E. boiler code for con struction 15 lbs., and for rating with the S.H.B.l. simplified practice recommendation. Also built for 100-150 lb. pressures.
Equipment--Steel base assembled with cast iron ash pit front and four cast iron comer posts: heavy rocking or dumping grates: hackstand, fire and flue doors. Manhole furnished on No. 580 and larger. No fire brick furnished. Bridgewall omitted 576-581.
Firing Tools--Hoe, poker, slice bar, flue cleaner and handle.
Trimmings for Steam Only--Safety valve, steam gauge with syphon and cock, water column with water gauge, glass and cocks, damper regulator.
For Cut-atomy View 44S00** 5cric Hand-Fired Coal, ^ec page 24,
Specifications end Settlnf Measurements
Boiler Number............................................
. .Sq. Ft. . Sq. Ft. - ^ Btu. per Hour........... .. 1000s
.. Sq. Ft. Crete Are* (SHBI min.)........
Steck Height.....................
........ Ft.
Steck Height. Two Boilers. . . ........ Ft.
Seiety Valve Size..................... Shipping Weight..................... ........ Lb.
. .Ft. In.
D--Water Line.........................
J --Steam Supply Location. . . Ft. In. K--Safety Valve Location. . .
576
3500 5600
640
250 11.4
19 17 55
25 23 65
6 3 2
6100
42 6-7
60 70
68 62 70 38 6-0
14
577
4000 6400
960
266 12.2
20 18 60
26 24 70
6 3 2
6700
42 9-6H
60 70
68 62 70 36 6-6
15
578
4500 7200 1060
322 13.4
21 19 55
27 .25 65
6 3 2
7300
48 8-10
66 73
71 66
74H 36
6-0
14
N--Return Height........... . . .
R--Firebox Height.................. T--Baee Widtk......................... U--Baee Length....................... V--Baee Height....................... W--Breeching Connection Leri tth. .In. X--Breeching Connection Width... .In. Y--Breeching Connection Location. . In. Z.--Rear Door Clearance .... .......... In.
EE--Foundation Length........
Outside Surface to Cover. . . . Sq. Ft.
19 36 50 4135 50 4735 5935 14 32
9 64H2
36 4235
33 54 60M
i i5
19
36 50 4135
50 4735 5955
14
32 9 6 35 42
36 4235
44 54 60 H
No E No B
125
19
42 50 44
50 53 H
60 14 34 11 735 46 42 43 36 60 61
130
579
5000 6000 1200
356 14.5
22 20 60
26 26 70
6 3 235 7900
48 9-635
66 73
71 66 7435 38 6-6
15
560
6000 9600 1440
429 16.4
23 21 60
30 26 70
8 4 235 9000
54 9-235
94
7935
7735 96 81 40
2-6
60
561
7000 11200
1660
500 16.1
24 22 65
31 29 75
6 4 235 10000
54 10-6
94
7935
7735 96 81 40
2-6
16
i9
42 50 44
50 53 H
60 14
34 11
735 46
42 43 44 60 61
1935 48 50 49
50 5935,
60 14
40 12 6 30
4735 <3 39
6535 61
1935
46 56 49
56 5935
66 14
40 12 8 30
4735 49 46
6535 67
140 155
i?o
582
6500 13600 2040
606 20.5
26 24 60
34 32 70
6 4 3
11500
60 11-1
101 6435
8235 103 66 41 3-0
16
'2235
53 72 49
61 66 63 17
44 14 9 33
5235 56 36
7035 64
165 46 195
583
10000 16000 2400
715 22.5
26 26 70
-36 34 60
6 4 3
13000
60 12-9
101 6435
6235 103 66 41 3-0
16
2235 53 82 49
61 66 93 17
44 14 9 33
5235 56 46
70.35 94
I8S 95 225
564 565 566
12500 15000 17500 20000 24000 28000
3000 3600 4200
693 1072 1250 25.6 28.4 30.9
30 31
33
28 29 31
70 80 60
40 41
44
37 36 41
80 90 90
6 4 2-2
15200
6 4 2-235 17300
0 4 2-235
19300
66 12-10
107
8935
66 14-9
107
8935
72 14-9
113 94
8735 109 89 41 3-0
#7K 109
69 41 11-0
92
115 96 41 11-0
16 16 15 12
7-0 7-6
2235 2235 2235
59 59 65 62 66 66 52 52 5435
67 >3 73
72 72 78 93 97 97 17 17 17
5Jj 15
935 36
5jj 15
935 36
54 19
1135 39
58* 62 46
7635 94
5835 66 66
7635 96
64 68
66
82 98
200 200 220 60 60 66 245 260 295
* Front smoWebox end I ront hesd below amokebox NOT included.
587
20000 32000
4600
1429 33.2
35 33 85
47 44 95
6 4 2-235
21200
78 14-9
115 9635
9435 117 97 37 3-0
16 12
2235 71 90 55
67 84 10135 17
60 16 11 42
70 62 62 66 10235
240 150 310
566
25000 40000 6000
1766 37.4
39 36 95
50 47 105
10 6 2-235 25000
78 17-735
115 9635
9435 117 97 37
12-4
16 12
589
30000 48000
7200
2143 41.2
41 36 100
54 50 110
10 6 2-3
26400
64
'7;?35 125 105
103
'27,h 109 41
12-4
16 12
590
35000 4 56000
6400 .
2500 44.7
43' 40 110
56 52 120
10 6 2-3
31700
64 23H3V,
12$ >05
103 >2734
109 41 13-0
16 12
2335
71 102 55
79 64 11335 17
60 18 11 42
70 74 82 88 11435
240 150 365
2735
77 102 57
79
9035 U335
21
64 22 13 45
76 74 80 94 11435
315 160 400
2735
77 108 57
85
,9034 11935
21
64 22 13 45
76 60 84 94 12035
315 160 450
Copyright Oct. 1919. Printed in U. S. A.
Kewanee Up-Draft Portable Boiler "800" Series
Specifications and Setting: Measurements
Number of Boiler....................................
832 833 834 835 636 837 838 839 640 841
.Sq. Ft. 7920
Capacity, Water ...................................
12670
8750 14000
8?70 44030
10310 16500
12170 19470
14210 22740
16000 25600
17930 28690
20710 33140
24230 38770
Width of Boiler...................................... .Inches 48 48 54 54 60 60 66 66 72 72
.Sq. Ft. 19.9 Heating Surface....................................... .Sq. Ft. 566
21.7 625
20.8 666
22.9 763
25.2
25.2
30.5
32.9
36.3
38.9
910 1018 1143 1281 1479 1731
42 42 48 48 53 53 59 59 65 65
Height of Firebo*............................ .Inches 44
44
49
49
49
49
52
52
5454
54%
Size of Steam Opening..........................
888888 68 6 8
Sice of Return Opening........................
5 5 5 566 666 6
Inches
3
3
3
3
33i 355 4
4 2-2% 2-3
Outside Surface to Cover......................
175 190 195 210 235 255 260 285 300 335
Diameter of Breeching. One Boiler . Inches 26 26 28 28 30 32 34 34 36 36
.Inches 24 24 26 26 28 30 32 32 34 34
Height of Stack. One Boiler................ . . .Feet 60
60
65
65
65
70
70
70
80
90
Diameter of Breeching. Two Boilers . .Inches 38 38 40 40 44 46 50 50 52 52 Diameter of Stack, Two Boilers.. . ..Inches 35 34 36 36 40 42 46 46 48 46 Height of Stack. Two Boilers........... . . . Feet 70 70 75 75 75 80 80 60 90 100
Approximate Weight............................. Pounds 11400 12200 13000 15500 16000 17000 19800 21500 23600 25700
A--Thickness of Foundation Walls ..Inches 9 B--Length of Boiler ......................... Ft. In. 11-5
9 12-5
9 10-10
9 12-1
13 12-7
13 13-10
13 13-0
13 14-3
13 13-11
13 15-8
C--Length of Firebo*........................... .Inches 68 74 62 68 68 74 74 80 60 66
71 77 65 71 72 78 78 64 84 90
. Inches 53 43 49 49 53 53 59 59 65 65
F--Ash-pit Wall to Pier .
Inches 40
45
38 46 48 60
48 57
51
66
G--Height of Breeching Connection.. Inches 82 82 91 91 94 94 99 99 104 104
H--Height of Boiler............................ 1nches 924
92% 101
101
106 106
112%
116 118
.5. I 1
"
1--Location of Steam Supply ..
1 nches
fC--Location of Safety Valve
. . Inches
L--Height of Water-line....................
M--Height of Ash-pit.......................... Inches
N--Height of Pier . . ......................... Inches
0--Height of Water Column............ . . Inches1]
P--Height of Steam Supply ............ Inches!
O--Height of Return ........................
R--Width of Breeching Connection. . ..1nches
S--Length of Breeching Connection . .Inches
T--Ctr. toCtr. Bolts in Ash-pit Front . Inches!
U--Ctr. to Ctr Bolts in Ash-pit Front Inches
W--Boiler to Center of Breeching
. Inches
33 74 78 14 104 76
95 20 15
38 48
8 10
35' i 8i yt 78 (4
105a 76 95 20 14 38 48
8
10
25
764 87 14 13!-$
85 103 20
14 42 54
8 10
33 78 87 14
1354 85 103 20 14 42 54
8 to
33%
81 Hr 91 17 12 88
108 23 15 50 60 11
1054
36 85 91 17
12
68
108 23
15 50 60 11 10%
30 88 % 17
11 54 93 115 23 17 54
66 It
11 54
32 96 96 17
Hi 93 115
23 17 54
66 II 11%
3254 89
101 17 11 98
120
23 19 54 72 II
12 54
4l'4 92 101 17 II 96 120
23 19 54 72 It 1254
Size of Steam Supply ....................
Inches I 6
6
8
8
8
8
8
8
8
8
Sice of Return ................................. ..1nches
5
5
5
5
6
6
6
6
6
6
Sice of Safety Valve
Inches! 3
3
3
3
3 54 354 4
4
2-2 54
2-3
Number of Common Brick ...
380 400 425 450 725 755 775 605 835 865
Outside Surface to Cover..............
Sq. Ft.' 175
190
195 210 235
255
260
285
300 335
'Foundation not included. Capacity for Oil, Gat or Stoker-Steam, 9620 to 42700 sq. ft.; Water, 60% Greater than Steam.
842
30700 49120
78
42.6 2193
71 55
10 6 2-3 370
40 38 90
56 54 100
29400
13 16-8
66 90 71 78 105 W 1 1954
4154 106 10254
17 I2H 9954 122 23 21 60 78 11 1354
10 6 2-3
915 370
35170 56270
78
45.5 2512
71 55
10 6 2-3 410
42 40 100
56 54 110
32000
13 18-7
92 96 71 94 105% 1193,
39' . 129 102%
17 12% 99 >, 122 23 21 60 78 11 13.%
10 6 2-3
960 410
7>t Plumltrtt snrf HtaUnf Cslsfsf
/ /'
Kewanee Smokeless Portable Boiler "900" Series
Specifications and Setting Measurements
Number of Boiler................................................... 932 933 '934 935 936 937 938 939
940 941
Capacity. Steam .................................... Sq. Ft. 7360 Capacity. Water...................................... Sq. Ft. 12100
8840 14140
10070 16110
10810 17300
12940 20700
15260 24420
17110 27380
18300 29280
20870 33390
21760 34620
Width of Boiler....................................... . Inches Area of Upper Grate.............................. Sq. Ft. Heating Surface....................................... Sq. Ft.
48 15 592
48 16.5 644
54 16. 13 719
54
19.48 772
60 21.03
924
60 23.25 1090
66 25.86 1222
66 27.09 1307
72 29.90 1491
72 31.71 1554
Approximate Weight ........................... Pounds 12100 12700 14600 15400 18000 19700 21900 22900 25800 26700
Length of Firebox.................................... Width of Firebox..................................... Height of Firebox.....................................
78 84 84 90 90 96 96 102 102 108
42 42 48 48 53 53 59 59 65 65
44
44
49 1 49
49
49
52
52
54 'A
54 H
Size of Steam Opening..........................
88 8 68 8 8686
Size of Return Opening...........................
5 5 5 56666 66
Size of Safety Valve Opening................ .Inches
2'4
3
3
3
34 3H 4
4 2-214 2-2^2
Outside Surface to Cover...................... Sq. Ft. 180 190- 205 220 240 270 280 295 305 320
Diameter of Breeching. One Boiler. . . . .Inches 26 26 28 28 30 32 34 34 36 36
Diameter of Stack. One boiler..............
24 24 26 26 28 30 32 32 34 34
Minimum Height of Stack, One Boiler . . . Feet 60
60
65
65
65
70
70
70
80
90
Diameter of Breeching. Two Boiler*.. .Inches 38 38 40 40 44 46 50 50 52 52
Diameter of Stack. 1'wo Boiler* . .
. Inches 34
34
36
36
40
42
46
46
48
48
Minimum Height of Stack. Two Boiler* . ..Feet 70 70 75 75 75 80 60 80 90 100
A---Thickness of Foundation Wails .. . Inches
9
B--Length of Boiler............................... . Ft. In. 11-8
999 12-6M 11-84 I2-5M
13 13-0
13 14-9
13 13-11
13 14-9
13 14-4
13 14-11
C --Header to Bridgewall.....................
12'A
14
14
15
15
16
16
17
17
16
D--Length of Ash-pit....................... . .
56 62 62 66 63 69 69 75 75 75
E--Length of Grate ...........................
55 61 61 67 61 67 67 73 73 73
F--Height of Ash-pit.......................... Inches 14 14 14 14 17 17 17 17 17 17
G--Bridgewall to Rear Wall................. . Inches 12 12 12 12 13 13 13 13 13 19
H--Height of Boiler..............................
92 4
92 'A tot
101
106
106
1124 1124 116
116
J--Width of Ash-pit................................ K--Rear Wall to Pier........................... L--Length of foundation....................
M--Height of Pier...................................
N--Height of Breeching Connection.. Inches O--Location of Steam Supply............
P--Location of Safety Valve ............ Q--Bolts Centers Asn-pit Front......... .1nches R---Height of Water-line......................
S--Width of Smoke Neck.................... .Inches
T--Length of Smoke Neck ................ U--Height of Steam Supply................ .Inches V---Height ot Keturn............................ W--Boiler to Center of Breeching... . Y--Height of Water Column ............
Z--Thickness of Bridgewall................ .Inches
43
32 90
105*
82
25 55 48 78 14
38 95 20 10
76 13
43 36 96
ioh
82 26 594 48 78 14
38 95 20 >0 76 13
49 28 %
I3M 91 36 50 54
87 14 42 103 20 10 85 13
49
31 102
i3i;
91
35 57 54
87 14
42 103 20
10
85 13
53 33 107 12 94
3SS 564 60 91 15 50 108 23 10 w 88 18
53 49 113 12 94
334 65 4 60 91
15 50 108 23
104 88 18
59 36 113 im 99
30 68 66 % 17 54 115 23
114 93
18
59 41 119
m 99
32 71 66 96 17 54 115 23 114 93 18
65 34 119 11
104 32 57'-; 72 101 19 54 120 23 i2.; 98
18
65 34 125 11
104 304 66 72 (Of 19 54
120 23 12*.;
96 16
Number of Common Brick................. Number of hire Brick ..........................
625 650 1050 1075 1250 1300 1325 1375 1400 1473 155 155 185 185 190 190 220 220 230 230
Foundation not included. Capacity for Oil, Cas or Stoker--Steam, 10060 to 44670 *q. ft.; Water, 60% Greater than Steam.
942
29010 46420
78 38.59 2072
30700
114 71 55
10 6 2-3 365
40 38 90
56 54 100
13 16-7
16 81 79 17 19 1194
71 46 131 124 1054 32 694 78 1024 21 60 122 23 13 4 99.; 18
1500 290
943
36790 58860
78 41.56 2628
35000
120 71 55
10 6 2-3 435
42 40 100
56 54 110
13 19-9
19 87 85 17 19 1194
71 61 137 12' i I05!S 42 66 78 102.4 21 60 122 23 134 994 16
1575 290
The Plumbing end Heating Catalog
Kewanee, weld+rtvet f irebqx Jailer -- For Oil, Gas or Stoker a
---- iP DD-9A
--^
| l-cc- -CO
Tout Are* f_ | Openinfic
r NOTE
FRONT ELEVATION
Kewanee Weld+Rivet Up-Draft Fire box Boilers in "5000" Series include 11 sizes for Oil, Gas or Stoker.
This design features increased heating surface, steam space, disengaging area,
; NOTE I--Thu Dimmi * <rrMrr than Hcht of Bat ItiBoiltriNi )lt I tnl Laid.
NOTE t:--WhM Mf One Burnet, Finer Burner un Centre In f Boiler and uer
Sn|R Hearth Plan round of Double
NOTE 1 -- Steel PWle >(h Dampen lor Mounting Bur era, nleo Fire Brick lining nod Hci'th Anglei net (iinuihtd by K B Corp.
NOTE -- Tin. D>menwon
ton Non. SI]] to SIM mcluaiva.
furnace volume and water content,
yet takes up less room. The steel base is
shipped assembled. All seams are welded solid but the
longitudinal butt-strap joint is riveted as required in some
States and Cities.
"5000" Series conforms to these Codes: A. S. M. E. for construction 15 lbs. steam; S. H. B. I. for ratings.
j'`k.T7
2X" z 2>*" x 5.S** T Irani. 1*
re NOTE I
LONGITUDINAL SECTION
Equipment:--Steel base assembled, hackstand, fire and flue doors with frames; cleanout plugs, manhole, flue cleaner. But steel plate with dampers for mounting burners, also fire-brick lining and hearth angles not furnished by K. B. Corp.
Trimmings for Steam only:--Steam
gauge, water column,
Bue Comer Pott
and safety valve.
ToUl Area of Ports in Hearth < * FF FOUNDATION AND HEARTH PLAN AT O-O
Footingsmayberequiredunder base corner posts depending on
toil conditions.
Boiler Number........................................... . sq. ft.
'--Water...................................... .sq. ft. .sq. ft.
Furnace Volume.................................... cu. ft.
B--Boiler Length.................................. ft. in.
D--Water-line........................................ Breeching Diameter..............................
Stack Height.......................................... Breeching Diameter, Two Boilers. . .
Stack Height,
Two Boilers. . .
Steam Supply Sixe................................
ft.
in. in. ft.
Safety Valve Site.................................. Shipping Weight....................................
E --Water Column Height................. F --Steam Supply Height................... G --Breeching Connection Height...
in. lbs.
in. ia. in.
ft. in.
L --Return Height..........
N--Firebox Length.............................. P --Firebox Height....................... R --Base Width.................................... S --Base Length................................... T --Base Height.................................... U --Breeching Connection Length. . V --Brcechiog Connection Width . . . W--Breeching Connection Location
Y --Foundation Length....................... Z --Foundation Width........................ AA--Furnace Length.......................... BB--Furnace Width............................
DD--Bolt Centers in Plate................ EE--Bolt Centers in Plate................ * v --Porta or Openings Total Area .
--Pit Depth.................................... i--Rear Stand Location................. _ C --Hearth to Bottom of Boiler. . . Number of Fire Brick.......................... Outside Surface to Cover....................
in. in. in. in.
in. in. in. in. in. in. in. in. in. in. in.
in. . sq. in.
.ft. in. in.
sq. ft.
5133
91 lO 1 45SO
536 78
54 9-9
92 >4 76
25 23 55
32 30 65 8 5 3 8200
76 94 77 38 1-6 18 19
48 !4 56 46 58* 66 14
40 15* 9* 30 67 65* 47 36 8W 49* 4* 136
io
3-6 14
460 157
5134
10740 17180
632 87
54 1 1 -2
92* 78
26 24 65
34 32 75 8 5 3
9100
76 94 77 38 8-0 14 19
48* 62 46
58* 72. 14
40 IS* 9M
30 73 65*
53 36 8* 49* 4* 160 IO
4-6 14
500 178
5136
12530 20050
737 96
54 12-9
92* 78
28 26 75
' 36 34 85 8 6 3*
lOOOO
76 94 77 38 9-3 14 19
48* 68 46
58* 78 14
40 15* 9* 30 79 65* 59 36 8* 49* 4* 186
IO
5-6 14
520 201
5138
15080 24 130
887 1 14
60 12-3
lOO* 86*
29 27 75
39 36 85 8 6 3*
1 1500
63* 102 83* 40 8-9 14 22 54 68 46
65 79 17
44 17 10*
33 80 70*
59 42
9* 55* 5* 230
IO
4-9 17
620 21 1
5139
17580 28130
1034 125
60 13-1 1
too*
86*
31 29 85
41 38 95 8 6 4
12600
83* 102 83* 40 10-0 14 22 54 74 46
65 85 17
44 17 10*
33 66 70*
65 42 9* 55* 5M 264 10
5-1 1 17
650 238
O
10
5140
21180 33890
1246 151
66 14-1
105 88*
32 30 80
43 40 90 8 6 2-2* 15500
85* 106 85* 38 10-0 14 22 60 74 48
71 85 17 51 18 11
36 86 76* 65 48 11 61 * 5* 317 11
17 700 258
5141
24450 39120
1438 175
66 15-10
105 88*
34 32 90
45 42 lOO 8 6 2-2*
17000
85* 106 85* 38 11-0 16 22
60 80 48
71 91 17
51 18 11
36 92 76* 71 48 11 61 * 5* 366 18
7-2 24
860 289
5142
29310 46900
1724 209
72 15-5
11 95
36 34 90
48 45 lOO
IO 6 2-3 19400
92 1 12 92* 38 10-8 16 22 66 80 51
77 91 17 54 24 14
39 92 82 71 54 12* 67* 5* 440 22
6-7 27
970 306
5143
33490 53580
1970 239
72 17-3
11 95
39 36 lOO
51 47 1 IO 16 6 2-3
21300
92 1 12 92* 38 12-0 16 22 66 86 51
77 97 17 54 24 14
39 98 82
77 54
12* 67* 5* 500 27*
8-0 32* 1 150 341
5144
39540 63260
2326 282
78 17-9
1 17 98
41 38 lOO
54 50 1 IO
IO 6 2-3
24200
95 1 18 96 38 12-0 16 22
72 86 54
83 97 17 6d> 26 15
42 98 68
77 60 14 73* 5* 590 31 * 6-4 36*
1300 376
5145
45000 72000
2647 321
78 19-8
1 17 98
43 40 1 15
56 52 125
IO 6 2-3*
26500
95 1 18 96 38 13-0 24 22
72 92 54
83 103 17
60 26 15
42 104 88 66 60 14 73* SM 670 38*
9-10 43
1550 418
!t
` [s ts
Kewanee weld+ktvet Firebx
"5000" Series Up-Draft For Coal
------------*----------------------- t. ;j ,y -N.
'-b
***. *: ' *. * ` . V
1 * *4
CC-.............-j r
Kewanee Weld + Rivet Up-Draft Firebox Boilers in "5000" Series include 15 sizes for Burning Coal.
This design features increased heating surface, steam space, disengaging area, furnace volume and water content, yet takes up less room. The steel base is shipped assembled, with grates. All seams are welded solid but the longitudinal butt-strap joint is riveted as required in some States and Cities.
*'5000" Series conforms to boiler Codes of American Society of Mechanical Engineers and Steel Heating Boiler Institute: A.S.M.E. for construction 15 lbs. steam; and for rating with the S.H.B.I. Simplified Practice Recom mendation.
ULon^itudinol Section ----------- EE-------------------
1.
AA DD I
q',
'o> ______ i__________________ foundation Plan
Equipment: Steel base assem bled, heavy rocking or dumping grates, hackstand except 5076*7; fire and flue doors with frames; cleanout plugs, and manhole on 5082 and larger.
Firing tools: Hoe, poker, slice bar, flue cleaner and handle.
Trimmings for Steam only: Steam gauge, water column, Arco regu lator all complete and safety valve.
Footing* may be required under bate cor ner post* depending on *ol condition*.
Steam. Supply and Safety Valve located nearer front on 5076-7-6-9*80-1 -2-3-4 and 6.
Specification* and Setting Measurement*
Boiler Number................................................................ . . . .Sq. Ft. . .. .Sq. Ft.
Btu. per Hour........................... .... 1000'* ....Sq. Ft.
Grate Area (SHBI min.)......................... . . . .Sq. Ft.
Stack Height. One Boiler..................... .......... Ft Breeching Diameter. Two Boiler*........
Stack Height. Two Boilers..................... ............ Ft Steam Supply Size...................................
Safety Valve Size..................................... Shipping Weight......................................... .......... Lb.
5076
3500 5600 540
250 11.4
19 17 50
25 23 60
6 3 2
5100
5077
4000 6400
960
286 12.2
20 18 55
26 24 65
6 3 2
5600
5078
4500 7200 1050
322 13.4
21 19 60
27 25 70
6 3 2
6100
5079
5000 8000 1200
358 14.5
22 20 60
28 26 70
6 3 233
6600
5080
6000 9600 1440
429 16.4
23 21 60
30 28 70
8 4 233 7500
5081
700C II20C
1680
500 16. 1
24 22 65
31 29 75
6 4 233 8400
5082
8500 13600 2040
606 20.5
26 24 65
34 32 75
8 4 3
9600
5083
10000 16000 2400
715 22.5
28 26 70
36 34 80
8 4 3
10800
5084
12500 2000C
3000
893 25.6
30 28 70
40 37 80
8 4 2-2
12600
5085 5086
15000 17500 24000 28000
3600 4200
1072 1250 28.4 30.9
3jJ 33 29 31 80 80
41 44 38 41 90 90
6 4 2-233 14400
8 4 2-2 33
16100
5087
20000 32000
4800
1429 33.2
35 33 85
47 44 95
6 4 2-233
17900
5088 5089
2500C 30000 4000C 48000
6000 7200
1786 2143 37.4 41.2
3<3 41 36 38 90 100
50, 54 47 50 100 110
10 10 66 2-233 2-3 21200 24400
5090
35000 56000 8400
2500 44.7
43 40 IIO
56 52 120
10 6 2-3
27500
.... Ft.-ln C--Boiler Height Overall....................... D--Water Line.........................................
E--Water Column Height..................... F--Steam Supply Height....................... G--Breeching Connection Height........ H--Hear Stand Height........................... J--Steam Supply Location...................... ... Ft.-ln fC--Safety Valve Location.....................
N---Return Height...................................
O--Fireboa Width................................... P--Fireboa Length................................... K---Firebox Height...................................
S---Crate Length...................................... T--Ba*e Width......................................... U--Base Length....................................... V--Baae Height........................................
W--Breeching Connection Length. . . . X-*-breechtng Connection Width......... Y--Breeching Connection Location. . . 'L--Rear Door Clearance.........................
.......... ........
In In.
DD--Foundation Width......................... EE--Foundation Length........................ FFzGG--Fire Dr. Opng. for Coal. Oil & Ga*.. . In Fire Door Style..........................................
42 7-3
61 70
65 8IU
70 36 1-4 17
18
36H 50 42
50 47M
60 14
32 9
6M 42
36 43
54 61
42 5-0
81 70
68
8IM 70 38 1-4 17
42 6-11
81 70
65
8133 70 38 1-5 18
42 9-10
81 70
68
8133 70 38 1-5 18
48 46 9-9 11-133 8633 8633 73M 73 33
7133 86 74
38 1-5
18
7133 88 74
38 1-5
18
18 18 18 18 16
36M 50 42
50 47M
60 14
3633 56 42
56 47H
66 14
3633 62 42
62 4733
72 14
4233 56 44
56 5333
66 14
42H 62 44
62 5333
72 14
32 32 32 34 34 9 9 9 II II
633 633 633 733 733 42 42 42 48 48
36 36 36 42 42 43 49 55 49 55
30 35 39 46 54 54 54 60 60 61 67 73 67 73
One 12*20
One 15*23
Single Frame 6 Door
54 11-1 92 33
78
76 94 77 35 38 2-0 18
18
48H 72 46
61 5933
82 14
40 12 6 30
4733 56 36
6533 83
54 60 12-9 13-233 92 33 I00H
76 84
60 66 66 72 78 78 15-3 I4-5M 16-033, I6-8M 17-533 '9-833 100H 105 105 112 117 117
84 86 86 9433 96 96
76 94 7733 38 2-6 16
16
82 102
8333 40
2-6 18 12 21
82 102
83 33 40
10-9 16 12 21
84 106
8533 36
2-9 18 12 21
84 106
8533 38
11-0 16 12 21
9233 113
93 39
12-0, 18 12 22
94 116 % 36
12-3 18 15 22
94 118 %
38
13-0 24
15 22
82 46
67 5933
92 14
53H 62 47
73 66 93 17
5333 86 47
79 66 97 17
5933 86
7M 79 72 97 17
5933 90
<733
65 72 10133 17
65 33 102
5033
85 78 II3M 17
7133 102
5333
65 84 11333 17
7133 108
5333
91 84 II9H 17
40 44 44 51 51 54 60 60 12 14 14 15 15 19 16 18 8 9 9 933 933 1133 11 11 30 33 33 36 36 39 42 42
4733 62 48
6533 93
5233 68 51
7033 94
One 16*30
5233 74 72
7033 98
5833 74 60
7633 98
sen 80 75
76H 10233
64 80 72
82 11433
One 16*36
70 70 80 86 78 99 88 88 11433 12033
Two 15*23
Single Frame and Double Door*
R&L Single Fr. ft Dr.
175 175 185 185 200 200 220 240 240 35 50 40 40 40 40 85 110 110
'Outside Surface to Cover....................... ....Sq. Ft. 100 i io iio 130 140 160 177 202 227 260 265 292) 330 370 416
'Front smokeboz and front head below smokeboz NOT included.
CattUf jV*. SO A. 14
IV
FRONT ELEVATION
NOT* I--Th.
<a prcatcr than Hri(M of Baa* far Boikn N*. *4J. <144
LONGITUDINAL SECTION
Kewanee Weld-)-Rivet Smokeless Fire box Boilers in "6000" Series include 14 sizes for Oil or Gas as listed.
HOTS 1;--Wfcoi um| One Burart, Ptac* Burner C*UK law W BaJn Md use
Equipment: -- Steel base assembled, hackstand; draft, fire, grate and flue doors with
This design features increased heating surface, steam space, disengaging area, furnace volume and water content,
ft, at Tn Bnck launf *d Hcartk As|ln *( linaM by K. B Carp.
HOTS 4 -- Thi* Dimension
I*** an Nas, ttM to t)M
yet takes up less room; with the addi-
0
tion of the water grate and header for
extremely efficient operation. The steel base is shipped
assembled. All seams are welded solid but the longitudinal
frames; cleanout plugs, man hole, flue and tube cleaner, socket wrench. But steel plate with dampers for mounting burners, also fire brick lining and hearth angles not furnished by K. B. Corp.
butt-strap joint is riveted as required in some States
Trimmings for Steamonly:
and Cities.
,
Total Area of Port* in Hearth = FF b.k comer Pom
--Steam gauge, water column, and safety valve
"6000" Series conforms to these Codes: A. S. M. E.
FOUNDATION AND HEARTH PLAN AT 0-0
for construction 15 lbs. steam; S. H. B. I. for ratings. Footings may be required under base corner posts depending on soil conditions
Boiler Number......................................................
1 6126| 6127 6128 6130 613216134 613616138 6139 6140 6141 6142 6143 6144
Rating--Steam................................................... ... sq. ft. 486015470 6080 7290 8500 ;10330! 121 50 1 51 SO118220 21250 2429030360 3643042500
--Water.
............................... . . sq. ft. 7770 i 8750 i 9720 1166013600165201944024280 29150 34000 38860 48570 58280 68000
Heating Surface................................................. Furnace Volume
A--Boiler Diameter....................................... B --Boiler Length .
C --Boiler Height Over-all..................... D--Water-line.......................
Breeching Diameter .......................... Stack Diameter................................................. Stack Height........................................
Breeching Diameter, Two Boilers... .
Stack Diameter,
Two Boilers .. .
Stack Height,
Two Boilers
. . .sq. ft. 286 , . . cu. ft. 57 1
in. 42 | ... ft. in. 7-10 1
... in. ai i . . in. 71
... in. 20 | ... in. 20 1
ft. 45 in. 28 ! ... in. 26 1 ft. 55 i
322 63 42 8-9
81 71
22 20 45
28 26 55
i 358 66
i 42 9-6
| 81 71
| 22 | 20 ! 50
28 ! 26 1 60
429 84
48 9-9
86* 74*
24 22 50
32 30 60
500 88
48 1 1-0
86* 74*
24 22 60
32 30 70
606 104
54 10-9
9214 78
26 24 65 34 32 75
715 1 893 1 1 3 1 142
54 ; 60 12-3 1 12-3
9214 i 100* 78 86*
28 i 30 26 : 28 75 i 75
36 , 40 34 ! 36 85 i 85
1072 151
60 14-3
ioo* 8614
32 30 85
42 38 95
1250 181
66 14-3
105 88*
32 30 80 44 40 90
1429 187
66 15-9
105 88*
34 32 90 46 42 IOO
1786 224
72 16-1
111 95
38 36 90
50 46 IOO
2143 2500
261
304
72
78
18-6 18-11
111 95
1 17 98
42 38 IOO
44 40 IOO
54 50 1 IO
56 52 1 IO
Steam Supply Size .........................................
Return Size...........................................................
Safety Valve Size..................
Shipping Weight
...........
... ...
in. 6 4
in. 2
lbs. 5100
66 4!4 2 1 2*
5600 : 6100
8 6 2*
7000
8 6 2*
7800
8 6 2*
8900
S 8 8 8 8 IO IO 1 o
6 66666 6 6
3
3
314
2-2 2-214 2-2* 2-2* 2-3
101001 1900 1 3500 1510016700 19800 22700 25300
E --Water Column Height........................ F --Steam Supply Height.......................... G --Breeching Connection Height . . . H--Rear Stand Height........................ J --Steam Supply Location...................... K--Safety Valve Location ...................... L --Return Height..................................
M--Firebox Width.......................................... N --Firebox Length ..................................... P --Firebox Height ...
... in. in in
. . in. ... ft. in ... in
in
... in in in
69 si a
70 38 1 -5 18 18
36* 58 42
69 81 14
70 38 1 -5 18 18
36* 64 42
69 | 7214 81 14 ! 88
70 ! 74
38 38
1 -5
1 -4
18 17
18 19
3614 66 42
42* 69 44
72* 88 74 38 1 -5 18 19
42* 72 44
76 94 77 38 1 -5 18 19
4814 72 46
76 94 77 38 1-5 17 19
48* 78 46
83* 102 83* 40 1 -6
18 22
54 82 46
83* 102
8314 40
10-6 16 22
54 87 46
85* 106 8514 38 10-8
12 22
60 90 48
8514 106
8514 38
11-6 14 22
60 93 48
92 1 12
92)4 38
1 1-8 16 22
66 96 51
92 1 12 9214 38 13-0
16 22
66 102 51
95 1 18 96 38 1 3-6
16 22
72 102 54
R --Base Width................................................ ... S --Base Length............................................... ... T --Base Height....................................
in 46/4 in 67 in 14
U --Breeching Connection Length.. . . V --Breeching Connection Width .... W--Breeching Connection Location
X--Rear Door Clearance ..................... Y--Foundation Length............................... Z --Foundation Width .
... ...
...
in 32 in 1 1 14 in 7k in 24 in 68 in.! 52
AA--Furnace Length.................................... BB--Furnace Width..................................... CC --Burners Location................................ DD--Bolt Centers in Plate....................... EE--Bolt Centers in Plate....................... FF --Ports or Openings Total Area... GG--Pit Depth......................................
... in. ... in. ... in. ... in ... in . ..sq.in.
in
49
24 --
3714 4*
73 io
HH--Rear Stand Location........................ . . .ft- in. 1 >6
TT --Hearth to Bottom of Boiler
in 14
Number of Fire Brick....................................
360
Outside Surface to Cover .
. . sq. ft. 1 IO
46* 73 14
32 1 1 14 7*
24 74 52 55 24 -- 37* 4* 83 IO
1-10 14
385 1 18
46* 75 14
5214 79 14
32
1 1* 7m
34 13* SK
24 27 76 80 52 60
57 60 24 ! 30 --i 7 37* 1 43*
4k i 4h 92 : iio 10 IO
2-5 14
2-3 14
400 126
445 1 44
52* 82 14
34 13* 814
27 83 60
63 30 7 4314 4k 127 IO
3-3 14
460 160
5814 82 14
40 15* 9K
30 83 65*
63 36 8* 49* ah 155 IO
3-0 14
495 173
58* 88 14
40 15* 9*
30 69 65*
69 36 8* 49* 4k 182 IO
4-0 14
525 195
65 93 17
44 17 IO*
33 94 70*
73 42 914 55* 5K 230 10
3-6 17
650 213
65 98 17
44 17 10)4
33 99 70*
78 42 914 55* SK 273 id
5-1 17
675 244
71 ioi
17
51 18 11
36 102 76*
81 48 11 61 14 5k 320 11
4-8 17
730 262
71 104
17
51 18 11
36 105 76*
84 48 11 61 * 5k 365 11
5-1 1 17
750 289
77 107
17 54 24 14
39 108 82
87 54 1214 67)4 5* 455 12
5-1 1 17
805 319
77 13
17
54 24 14
39 1 14 82
93 54 1214 6714 5k 545 17*
7-10 22*
995 365
83 1 13
17
60 26 15
42 1 14 88
93 60 14 73* 5K 640 19)4 8-3 24*
1 105 401
1
/y
J(WANEE.WLD+i^rvET S^KELESS BOILER "6000" Series Down-Draft
For Coal
Kewanee Weld + Rivet Down-Draft Smoke
LONGITUDINAL SECTION Equipment: Steel base as
less Boilers in **6000" Series include 14 sizes for Burning Coal as listed.
This design features increased heating surface, steam
-GG9'
sembled with cast iron ashpit front and four cast iron corner posts, heavy rocking grates; hackstand except 6077-80:
space, disengaging area, furnace volume and water con tent, yet takes up less room; with the addition of the downdraft water grate for extreme smokeless operation. The steel base is shipped assembled, with lower grates. All seams are welded solid but the longitudinal butt-strap joint is riveted as required in some States and Cities.
**6000" Series conforms to the A.S.M.E. Boiler Code or construction 15 lbs. and for rating with the S.H.B.I.
draft, fire grate and flue doors
DO CC` *
with frames: cleanout plugs and manhole on 6062 and
larger, special fire-brick tile,
1
< _____
A
FF
first course to fit header. Firing tools: Hoe, poker,
slice bar, flue and tube clean
9' ers with handles, socket wrench.
simplified practice recommendation.
FOUNDATION PLAN
Sum Supply and Safety Valve located rear of Manhole on 608567-6-9 and 90.
Footing* may be required under base corner post* depending on toil condition*.
Specification* and Setting Measurement*
Trimmings for Steam only: Steam gauge, water column, Arco regulator all complete, and safety valve.
Boiler Number..................................................
Rating--Steam Radiation............... Sq. Ft. Water Radiation............... Sq. Ft. Btu. per Hour................... . 1000*
Heating Surface (SHBI min.)........ Sq. Ft. Urate Area (SHB1 min.).................. Sq. Ft.
Breeching Diameter........................... Stack Diameter................................... Stack Height........................................ .... Ft.
Breeching Diameter, Two Boiler*. . Stack Diameter, Two Boiler*........... .... In. Stack Height. Two Boiler*............... .... Ft.
Steam Supply Size............................. Return Size.......................................... Safety Valve Size...............................
Shipping Weight................................. .. . Lb*.
A--Boiler Diameter........................... B---Boiler Length............................... .Ft. In. C--Boiler Height Overall................. D--Water Line...................................
E--Water Column Height............... K--Steam Supply Height................. G--Breeching Connection Height. . H--Kear Stand Height..................... J--Steam Supply Location.............. Ft. In.
K--Safety Valve Location...............
N--Return Height.............................
0--Firebox Width............................. P--Firebox Length............................. R--Firebox Height.............................
S--Crate Length................................ T--Ba*e Width................................... U--Ba*e Length................................. V--Bare Height..................................
W--Breeching Connection Length. X--Breeching Connection Width. . Y--Breeching Connection Location . ... In. Z--Rear Door Clearance..................
AA--A.h Pit Width........................... BB--A*h Pit Length......................... CC--Bridgewall to Kear Wall........ .... In.
FF--Foundation Width................... GC--Foundation Length.................
Number of Common Brick............. Number of Fire Brick....................... "Outside Surface to Cover............... Sq. Ft.
60?7
4000 640C
960
266 12.2
2C ie 55
26 24 65
6 3 2
5600
42 6-2
61 70
64 8IM
70 36 1-5
16
16
36W 62 42
37 42 V 7IM
14
32 9
bV 42
36 31 2iH 10
54 72M
135 100 no
6076
4500 720C 1060
322 13.4
21 IS 60
27 25 70
6 3 2
6300
42 6-6
81 70
66 8IM
70 36 1-5
16
16
3b V 62 42
43 47M 7IM
14
32 9
bv 42
36 37 7J4 ||
54 72M
135 too 115
6075
5000 800C 1200
356 14.5
22 2C 60
26 26 70
6 3 IV, 6600
42 9-6
61 70
66 am
70 36 1-5
16
16
36 H 66 42
43 47M 74M
14
32 9
bV 42
36 37 20V nk
54 75 H
135 100 125
6060
6000 960C 1440
429 16.4
23 21 60
30 28 70
6 4 IV 7700
46 9-7 86 M 73H
7IM 66 74 36 1-5
16
16
42H 64 44
43 53H 73H
14
34 11 7M 48
42 37 19|V|
60 74M
155 120 140
6061
700C 1I20C
1680
50C 16.1
24 22 65
31 29 75
8 4 2V 6600
48 11-0 86H 73 V
21V 66 74 36 1-5
16
16
42H 72 44
49 53H
62 14
34 11 IV 46
42 43 22 12 39 60 63
155 120 160
606)
8500 I360C 2040
606 20.5
26 24 65 34 32 75
6 4 3
9900
54 10-6H
91V 78
76 94 22V 36 2-0
18
id
48H 72 46
49 i9V
62 14
40 12 8 30
47M 43 22 12 36
biV 63
175 150 170
4683
I000C I600C 2400
715 22.5
28 26 70
36 34 60
8 4 3
11200
54 I2-4H
92V 78
76 94 22V 36 2-6
18
18
V 62 46
55 59M
92 14
40 12 8 30
47H 49 26 13 46
65 V 93
175 170 195
6064
12500 2000C
3000
693 25.6
3C 26 75
4 37 65
6 4 2-2
13100
60 I2-9H
I00M 64
82 102 83 V 40 2-6
16 12 21
53H 62 47
55 66 93 17
44 14 9 33
52H 50 26 M 46
70M 94
185 175 220
6085
15000 2400C
3600
1072 28.4
31 29 65
41 38 95
8 4
2-2M 14900
60 I4-9M
100M 84
82 102 83 V 40 10-6
16 12 21
53H 66 47
61 66 97 17
44 14 9 33
52 V 56 24 15
66 70 V
98
185 175 250
6066
17500 2600C
4200
1250 30.9
33 31 65 44 41 95
6 4 2-2 H
16600
66 I4-0M
105 66
64 106 85H 38 2-9
18 12 21
i9V 86
*2V 61 72 97 17
51 15 9M 36
58M 56 24
57
76H 98
200 190 260
608?
2000C 3200C
4600
1429 33.2
35 33 95
47 44 105
6 4 2-2V 16300
66 I5-7H
105 66 64 106 85 V 38 11-0
16 12 21
i9V 90
42V 61 72
101V11
51 15 9K 36
58M 56
28H
2bV 102V
200 200 265
6066
25000 4000C
6000
1766 37.4
3S 36 95
50 47 105
10 6 2-2H 21500
72 tb-4V
112 94V
92 V 111
93 39 11-9
18 12 22
biV 102
50K 67 76
II3M 1?
54 19 1IM 39
64 62 34V
62 114V
220 260 330
6089
30000 4600C
7200
2143 41.2
41 36 105
54 50 115
10 6 2-3
24500
78 17-1
117 96
94 116 96 36 12-3
16
22
7IU 102
53H
67 64 113 H il
60 18 11 42
>0 62 34M f}
66 II4H
240 305 360
6090
35000 56000
6400
2500 44.7
43 40 115
56 52 125
10 6 2-3
27300
76 19-4
117 96
94 118 96 38 13-0
24
22
7IV 106
33V >3 64
Il9tf ii
60 18 11 42
70 66 34H
66 120X
240 305 410
' Front amokebox and frost head below *mokebox NOT included.
fiiwnci C*fbf Nm. 90 k.
[(EWANE& "G" SERIES
1^911-ER -- For Burning Coal a ~
3*-------- b
.O
.y^TTH
P/*'.*.<>*'
v * ,V
The Kewanee "G" Series Smokeless Boiler is a single-pass portable firebox boiler with down-draft grates. All seams electrically welded. The steel base is shipped assembled, with lower grates. For heating average to medium size buildings where smoke ordinances are stringent, this "G" Series effectively fulfills welded smokeless boiler speci fications.
Kewanee "G* Series Boiler
*`G" Series conforms to boiler Codes of American Society of Mechanical Engineers and Steel Boiler Institute: A.S.M.E. for construction 15 lbs. stcain; and for rating with the S. B.I. Simplified Practice Recommendation.
Equipment:--Steel base assembled, with heavy rock ing grates, hackstand; draft, fire, grate and Hue doors with frames; handholes and cleanout plugs; special fire brick tile first course to fit header.
L.uw /
FOUNDATION FLAN
Firing tools:--Hoe, poker, slice bar; flue and tube cleaners, socket wrench.
Trimmings for Steam only:-Stcain gauge, water column, safety valve, nil complete.
Damper regulator if required.
Boiler Number................................................
SBI Rating--Steam Radiation.................. --Water Radiation..................... --Btu per Hour............................
.............sq. ft. .............1000's
SBI Net Rating--Steam...........
...
--Water................................... --Btu per Hour..................... .............1000`s
Heating Surface, SBI min.................................
Grate Area,
SBI min.................................
Safety Valve Capacity...........................Lb. steam per hour
A --Boiler Diameter............................................ B --Boiler Length..................................................
C--Boiler Head Height Over-all................ D --Water-line.........................................................
Breeching Diameter.............................................. Stack Diameter........................................................ Stack Height..............................................................
Breeching Diameter, Two Boilers...............
Stack Diameter,
Two Boilera...............
Stack Height.
Two Boilera...............
Steam Supply Size............................................ Return Size............................................
.............
ft.
Shipping Weight...................................
B --Water Column Height............................. F --Steam Supply Height, Flanged **. . G--Steam Supply Location...................... H --Safety Valve Location..................... J -- Return Height.....................................
K --Firebox Width................................ L --Firebox Length........................ M--Firebox Height..........................
N --Bate Width........................................ . P --Base Length........................ R --Header to Bridgewall............................. S --Grate Length....................................... T --Ash Pit Length...................... U --Bridgewall Thickness............................. V --Rear Double Door Clearance..............
--Space to Draw Tubes................................ W--Breeching Connection Length............. Y --Shell Extension Depth.............................
Number of Common Brick................... Number of Fire Brick.................................... "Outside Surface to Cover.............................
sq. ft.
G -1 8
1800 2880 432
1 500 2400
360
129 7.9 645
36 8-0
63 - 54
16 14 40
22 20 45
6 3
3500
52 67`A 6-0 20* 18
31 52 37
41 61
9 31 32
9 21 1 -9 24 12
85 90 86
G-22
2200 3520
528
1830 2930
439
1 58 8.9 790
36 9-0
63 54
17 15 40
23 21 45
6 3
3900
52 67 Vi 6-9 12 18
31 52 37
41 61
9 37 38
9 21 2-6 24 12
75 60 91
G -26
2600 4 160 624
2170 3470
521
1 86 9.7 930
36 10-4
63 54
18 16 45
24 22 50
6 3
4300
52 67 Vi 7-6 12 18
31 58 37
41 67 io 37 38
9 21 3-3 24 12
85 90 102
G -30
3000 4800 720
2500 4000
600
215 1 0.5 1075
36 1 1 -4
63 54
18 16 45
24 22 50
6 4
4700
52 67V4 7-1 1 16 18
31 58 37
41 67 IO 43 44
9 21 4-6 24 12
75 80 1 16
G-35
3500 5600 840
2920 4670
700
250 1 1 .4 1250
36 12-10
63 54
19 17 45
25 23 50
6 4
5100
S2 67'A 8-7 18 18
31 64 37
41 73 11 43 44
9 21 5-6 24 12
75 80 126
G-40
4000 6400 960
3330 5330
600 286 "
12.2 1430
42 1 1 -4
69 58
20 18 45
26 24 50
6 4
5600
56 73 Vi 0- 1 12 18
37 61 41
47 70
9 37 38
9 24 4-3 30 12
85 lOO 125
G-45
4500 7200 1080
3750 6000
900
322 1 3.4 1610
42 12-4
69 58
21 19 45
27 25 50
6 4
6100
56 73'A 8-8 16 18
37 64 41
47 73 IO 43 44
9 24 5-0 30 12
85 lOO 135
G -50
5000 8000 1200
4170 6670 1 OOO
358 14.5 1790
42 13-4
69 58
22 20 45
28 26 50
6 4
6600
56 73* 8-1 1 21 18
37 66 41
47 75 11 49 50
9 24 5-9 30 12
85 lOO 150
G-66
6000 9600 1440 5000"
6000 1 200
429 16.4 2145^
42
15z5 69 `
58_
23 21 50 30 28 55_
"s'
4_ 75QO~
*56
74 9.6 21
19__
37 72 41 ` 47 "
81 11 55 56
9 24 7-6 30 J 2___ " 85
lOO 171
On G-1S only Sofcty Valve Location H it 20" to left of steam supply, instead of to right at shown for at) other siiet "Threaded outlet height 3* lest.
Front head NOT included
17
18
KEWANEE "P" series plREBx5?ll-ER -- For Burning Coal
FRONT ELEVATION
Th. KmnH *P* Series Hr*box Boiler Is s single-peas portable up-draft boiler. All seaaa are welded. Steel base Is shipped assembled with grates In place.
P* Series eonfqrme to ASHE Boiler Code tor con struction IS lbs steaa, SO lbs water, and with 8 B I rating code.
BVimarr:--Steel base assembled with east Iron ash pit fsnt,and four cast Iron corner posts, and heavy rock ing or duaplng grates; beckatand; fire and flue doors w(Ap tranes; handholes and cleanout plugs.
rlRINO TOOLSHoe, poker, slice bar, flua cleaner and handle.
TOUmnoB Tor Steaa Only:--Safety valve, atsaa gauge, syphon and cock, water coluon with gauge and cocks, daoper regulator all cooplste.
Boiler Number............................................................ P-18
tfBl Ratlngr-Steara Radiation . . . . --Water Radiation . . . . . Sq Ft --Btu perlHour......................
IB00 2860
432
3I Net Rating--Steam .......................... --Water .......................... --Btu per Hour. . . .
1500 2400
360
Heating Surface, Sdl min......................
129
Spats Area,
SBI min......................
7.9
Safety Valve Capacity . .Lb. Steam per Hour - 645
A-Boller Diameter ................................... p-Boller Length ....................................... O-Boller Head Height...............................
D-Water Line................................................
36 7-7
63
54
Breeching Diameter................................... Stack Diameter........................................... Stack Height. ... ...............................
16 14 35
Breeching Diameter, 2 Boilers . . .
Stack Diameter,
2 Boilers . . .
Stack Height,
2 Boilers . . .
22 20 40
Steam Supply Size ................................... Return Size ................................................
6 3
Shipping Weight .......................................
3240
P-22
2200 . 3520
528
1830 . 2930
439
156 8.9 790
36 9-0
63 54
17 15 35
23 21 40
6 3
3550
E-Vater Column Meltfit .......................... r-Steaa Supply Height, Flanged**. . 0-Steam Supply Location ...................... K-Safety Valve Location ...................... . . .In
K-Flrebox width ....................................... L-Flrebox Length....................................... H-Flreoox Height.......................................
N-Bass Width................................................ P-Base Length ........................................... T-Brsechlng Connection Length . . . V-Rear pingle Door Clearance, min . . .In W-Rear Space to Draw Tubes . . . . Outside Surface to Cover ..................
52 67j 5-2 12
31 3B 37
41 47 24 36 2-5 80
52 67* 5-10 12
31 44 37
41 63 24 36 3-4 93
Front Head NOT Included. ** Threaded outlet height 3" less.
LONGITUDINAL SECTION
SECTION X- X
P-26
2600 4160
624
2170 3470
521
166 9.7 930
36 10-4
63 54
18 16 35
24 22 40
6 3
3900
62 67* 7-0 12
31 50 37
41 59 24 36 4-2 106
P-30
3000 4600
720
2500 4000
600
215 10.5 1075
36 11-4
63 54
18 16 40
24 22 45
6 4
4160
52 67* 7-6 16
31 60 37
41 59 24 36 6-2 116
P-35
3500 5600 840
2920 4670
700
250 11.4 1250
36 12-11
63 54
19 17 40
25 23 45
6 4
4550
52 57* 6-0 18
31 56 37
41 65 24 36 6-3 132
P-40
4000 6400
960
3330 5330
800
266 12.2 1430
42 11-0
69 SS
20 16 40
26 24 4S
6 4
5020
56 73* 7-6 12
37 SO 41
47 59 30 42 4-10 130
i
j
P-45
4500 7200 1060
3750 6000
900
322 '3.4 1610
42 12-4
69 56
21 19 40
27 25 45
6 4
6500
56 a73* 6-0
16
37 56 41
47 65 30 42 5-8 144
P-50
5000 6000 1200
4170 6670 1000
356 14.6 1790
42 13-7
69 68
22 20 45
26 26 SO
6 4
5960
56 73* 9-0 21
37 62 41
47 71 30 42 6--6 156
P-60
6000 9600 1440
5000 8000 1200
429 IS.4 2145
42 15-8
69 56
23 21 45
30 28 SO
a 4
6940
66 74 10-0 16
37 66 41
47 77 30 42 8-0 162
1
i.
t0
fpl
i^
f\
20
<o rJ p* d
0 0 0 14 X*
0 0 o
M)
C0 1 r O'
O
p*
GO
r
U) UJ
o;
v d
oor r X
J X'
d x
Ul <r
pj in
cC d
Ul O
O
^0 x>
cO 10 O'
O d o J H
O d
(0
0 0 0 0 X*
0
0 0
oO
1
cO r r
d
ifl 0 N-d.
cC
<r (O
cO
r*
in m
r o X
JO X fO
d Ul XI aO
rJ in
cX> d
ll O'
O
^0
x> N
oO TT
10
d cO
O
X oO d
o d
r*
tO o r d
0 o o U) fj
0 0
J>
o r~ r
d
P oO
ut U)
<o pi
vfi (Si
Ml j
C" O' X in d
01"0
X
d 10
fj UJ XI O'
O U)
J d
U) o
o
< Ji
pi
J (O O'
0
d 0 x>
r x>
x>
xi *
d
0 0 o r>
o
o o J>
rJ r~
i
X
O' <0 o
ffl
0 cO
U)
d <0 d i d
00
X **
d t<\
r* x\
0 <fi
0 U?
j d
o <r
cO
_j
-J pj ri
J *--
rO
0
(~ tO
r X*
N
io <c
0 0 0 o cJ
O
o o
j
x
<o
oO fO rJ
(
0 cO
O' m
p< U)
o X d
l~ X <o
r> (O
o x>
o O'
J d
d
0 o
<D
sj d
O O'
r o
o
o cr
M)
O'
<5
( r 5
o o o cO
0 o <0
5
*$ 9
O' i U)
in r" o
<o
<r in
O
r* m
or X d
00
J X (O
0 x>
<0 0 d p> oo d
o d
o O'
oO
^9
s4
O O'
o
i" o
CO U) <0
in fCl
C
v O
o
( J
<
0 o o u>
o] as
CS |
p> i
O' pj Or'
<-
U)
<r d
r O' X d
V) r
y <o
aO r>
*3
oo aO d
j <o
o <r
0
r* 10 X> a0
o
o
o rJ W
r* m
o
c
IX Ifl
d
o0 o0 o U) ro
fJ
0 sP Vj
rJ oO GO p)
H J
i" m
O' d
r (0
X
d
XI in X <o
10 N
x>
oo oO d
d fO
o O'
dO
10
x>
f00
o
0
0 40
r* x>
*
c
V
O
cfi
tO d d
o0
0 U)
0 o
0
rfO
o r"
t" CJ
aO sj
dO
<r d
<a r X d
d d
X
<o
J <d
j
pj
o r
oO x>
d x>
o oO
oO
10 <0
cC oO or
0
d d
c> to
6 \ tfi x o
0 o o o
0 o U) J
o -i)
U) r!
cC
r o
fj oO o
d
in
X d
o X)
X fO
J N
pj p
U)
oO d X> X
in t"
aO
10
(O
m cC 00 0"
0 0 d
rJ
<n v o
<0 o
rf 5
o <0 C-
0 o O H
i
< pf
U) j
in
d
r-
d d
. X to
J fj y <*
-i P*
X*
od d rrt
0 X) f
J si
x^
sj O' CO
0
o rJ o
00 fj
CO x o
_G
fO d
o o o r~
0 0d
U)
v.
r-
o uO
rft d
d d
d X xl
? rO
d cJ
H pj
io
d X>
in XI sj
O
-i
^r>
d
or CO
0 o o V
oO rJ
_ta> _o
<S
CO o
d
o o <o J
0 o <3 0
d in
0 o
O' H
p1 a
CO d dd
d m X rr*
o X <o
pj
P1 pj
U) in
d cO
x
Ul v9 d
o
J r
O' aO
0 x> 00
C0 rJ
-4-
v 0 (Z
XI O' o d
0 o J 10
0 in fj cr
oO
J.
<o r(O
0 U)
*3 <o
d
d
X X*
fXO
pj pj
ow o m
o XI
C0
U) -3
vS
pj fJ
o
O'
d CO
0 J r
d
sfi
V d v/1
<0 <>
O d
c0 o in c r~ d *-
aO d
1 or
O (O
-
J md
oO <4
X
o X
fj fj
cO x
o
O in
o <0 o x> w sj
o
pj
pi
r
d GO
o 00 o
r1
o
O O
d
(0 C" o *4
o o d
0 m " j
cO <
C" oO
00 <-- ro
J O'
oO
<o
d
XV x d aO XX o frt
p> pj
0
o m
0 xl
00 rJ
o -d
o d o sJJ S X3 pi r- oO dJJ fj
- -u+. <c Xl XI
c
c -V U-
--ar. . c
J?
J)
c
c
c
c .c
c -+ . c u-
X <c
c
-Z Vi-
,c
C .s
c
c
c
<r C0
O O U4
X
C0
e >0
ft. <r
ffV
5 cG '-4O-
o e*4 z
<3
* 3 Oco o
) j2
5 4Oo c <w
V
d 0 <0
V
d
s0<4)
` 0 *+
o V J
* o
C0
0 _s: "e d
vj) <5 C
dc
o Vd <3
-4dS
o -J "X <s
_-Oc* d
o0 dV IZ
_s -.+C O' VI
*X _p
V3
VO O
_>oQ
-+o
%d d
iZ iZ O
x <*
_
t
-# CV
V. x>
I S' c iZj w
X on
0 Z>
V
5
jtj 4 n
<5
s
.uo O U) . pX o 0 J
*w
5
H
o c _c
< e*
tO tS t"
V)
V
5 X3 x> fJ
e* Jol ~i(
0
</)
-.c*
<5 ' H
^5 *3
tcf '<
tG C ,c
c z
sv
o
d 4-
o
O
0
$
S^O
0 z%
t << 4
r '5 ti s-4
'1 iV 1
o -V
-4-
Vo e
0 ?
U f j o
M-
d X0 _ 01 V aX <1
V o
o
O
V a w
q)
c
X
5
Kewanee Horizontal Tubular Boiler
** r-fr.i -'-f -- `''^V '
With Full-Front Setting--Suspended Independent of Masonry
Specifications for Kewanee Horizontal Tabular Boilers, Half or Full Front
Longitudinal Seams, all Butt Jointed, Quadruple Riveted '
/
For 150 Pounds Working Pressure
Horsepower of Boiler as Rated . . . Code........................................................... Diameter of Boiler........................... Length of Tubes..................
Number of 3K-Inch Tubes .... Number of 4-lnch Tubes . . . Heating Surface for 3V4-Inch Tubes Heating Surface for 4-Inch Tubes Heating Surface for Shell ... Thickness of Shell................................ Thickness of Heads ...
Width of Grates.................................... Length of Grates................................ Area of Grates......................................... Diameter of Stack................................ Length of Slack.................................... Gauge of Stack................................ Length of Guys.................................... Diameter of Guys................................
. . . inches . . . . feet
. square feet . square feel . square feet
. . inches . . . inches
inches . square feet . . . inches . . . . feel
. . inches
fiO Pagan
60 16
54 44
791 7 737 2 167.6
i
,
4
60
54 22 5 28 60 14 600
A
i
i ; 1
Q0 Pacod
60 18
54 44 890 6 829 4 188 5
A
60
60 25.0 28 60 14 600
a
'
;
100 PaISE
66 16
66 54 967.6 901 8 184.3
A
66 54 24 75 30 60 14 600
A
no
Palet 66 18
66 54 1088 6
1017.9 207.4
A 4 no 60 27 5 30 60
14 600
A
!
125
Palla 72
16
86 70 1260 8 1172 9
201 1
H A
72 54 270 34 60 14 600
A
150
Palsy 72 18
86 70 1418.4 1319.5 226 2
H Ar
72 60 30.0 34 60 14 600
A
185 X
Pancit
72 20
86 70 1576.0 1466.0 251.3
H A
:
72 66 33.0 34 70
14
700
A
!
180
Pancy
78 18
110
88
1814.0 1658.8
245.2
H A
7R 60 32.5 38 60
12
600
A
200
Paper
78 20
no 88
2015.9 1843.1 272.4
B A
78 66 35.75 38 70
12
700
A
tSize of Steam Opening.................................... inches
tSize of Pop Safety Valves
inches,
Size of Water Gauge Glass and Gauge Cocks inches
Size of Water Column Connections . . . inches'
Size of Blow-off.................................................. inches (
Size of Feed and Check Valves.................. inches!
Size of Steam Gauge Dial........................... inches
4 Two 2 4
H Wi 2
14 814
Trimmings
5 Two 2 4
J4 Vi 2 V-i 84
5 Two 3
A V/, 2 1 'A 84
5 Two 3
H V4 2
1.4 8 *4
6 1 Two 3
1 'i 2A ! 14 8A
6
Two 3 M
\ \% 1 2A 1 14
84
66
Two 34
U Vk 14 14 24 2A 14 2 8 A &A
6 Two 34
4 14 24 2 8.4
Bare Boiler, for Full-front Setting . . Bare Boiler, for Half-front Setting Full Front.......................................................
Half Front............................................. Grates...............................................................
Other Castings.............................................
Trimmings...................................................... Stack and Guys.............................................. Weight Complete. Full-front Setting Weight Complete. Half-front Setting
. poundsj . pounds| . pounds
. pounds'
. pounds. . pounds
13350 13830
2400 1140 1040
380
145 1600 18915 18135
, 14700
1 15180 2400 1140
; 1420
380
' 45 1600
20645 19865
Weights
16025 16615 2590
1280 1090 395 255 1750 22105 21385
17660 1R250
2510 12tt0 1490
395
255 1750 24140 23420
| 19930 20755 2970
l 1510 1145
430
275 2000 26750 26115
21900 22725
2970 1510 1560
430
275 2000 29135 28500
23970
24795 2970 1510 1890
430
300 2300
31860 31225
26810 27835
3170 1700 1705
725
310 2800 35520 35075
29370 30395
3170 1700
2065 725
310 3300 38940 38495
Extras and Changes
Four Wall Plates and Rollers
..
Four Buck Bars and Cross Rods
Two Rear Diamond Washers with Rods
Fire-door Arch Liners
pounds pounds pounds! poundsl
With 3H*ir>ch tubes safety valves are one sze larger,
500
575 1 250 | 475 !
500 575 ; 260 !
475
500 1 630 i 250 I 475 1
500 630 260 475
Soo 750 250 475
500 750
260 475
t All openings over 3 inches will be forged steel flanged nozzles.
l 500 750
I 280 ! 475
500 1 800 260 500 t
500 800
280 500
21
Ketvanee Horizontal Tubular Boiler
With Half-Front Setting--Boiler Supported on Walls
Specifications for Keivanee Horizontal Tubular Boilers, Half or Full Front
Longitudinal Seams, all Butt Jointed, Triple Riveted
.
For 125 Pounds Working Pressure
orsepower of Boiler as Rated
Diameter of Boiler................................ Length of Tubes
Number of 3^-lncli Tubes
Number of 4-Inch Tubes .
Heating Surface for 3M-lnch Tubes
Heating Surface for 4-Inch Tubes
Heating Surface for Shell
...
Thickness of Shell
..................
Thickness of Heads
Width of Grates........................... Length of Grates................................ Area of Grates....................... Diameter of Slack ........................... Length of Stack.......................................
Gauge of Stack...........................
Length of Guys .... Diameter of Guys , .
. inches feet
. square feel . square feel . square feet . . inches
inches . . inches . . inches
square feet . . inches . . feet
. . . feet inches
80
Obduce 60 16
54 44 791.7
737 2 167.6
H X
bO 54 22 5 28 60 14 600
A
90
Obese 60 18
54 44 890 6 829.4 188 5
H 4
60 60 25 0
28 60 14 600
A
| I 1 1
1
100
ObjUR 66 16
66 54 967 6 904 8 184 3
A h
66 54 24 75
30 60 14 600
A
no
Oblat 66 18
oo 54 1088 6 10179 207.4
A
*5
6b 60 27 5
30 60 14 600
A
125
Obole 72 16
86 70 1260 8 1172.9 201.1
H X/7
72 54 27 0 34 60 14 600
A
Trimmings
tSize of Steam Opening .
. . . inches
tSize of Pop Safely Valves
inches
Size of Water Gauge Glass and Gauge Cocks inches
Size of Water Column Connections . . inches
Size of Blow-off
inches
Size of Feed and Check Valves . .
. inches
Size of Steam Gauee Dial
inches
4 'Two 2
! 1 'i 2
14 84
5 Two 3
4 >4 2
14 84
5 Two 3
*< 1,4 2
14 8
5 Two 3
s
14 2 14 84
16 Two 3
4' 14 24 14 84
Weights
Bare Boiler, for Full-front Setting .
Bare Boiler, for Half-front Setting . .
Full Front.......................................................
Half Front.......................
...
Grates.
...
...
Other Castings.............................................
Trimmings
.............................................
Slack and Guys
Weight Complete. Full-front Selling . .
Wetght Complete. Half-front Selling
pounds . oounds . pounds
pounds
. (xjundb pounds
pounos
puunos pounds
oounds
12560 13040 2400
1140 1040 380 225
1600 18205 17425
1 13790 i 14270
1 2400 1140 1420
1 380
225 1600
19815 19035
i 14970 15560
1 2590
1280 1090 ! 395
225 1750 , 21020
20300
16460
17050 2590
1 1280 1190 395
225 1750 , 22910 22190
18530
19355 2970
1510 1145
430 235
2000 25310
24675
150 Obtesd
72 18
86 70 1418 4 1319 5 226 2
B 17 72 60 30 0 34 60 14 600
A
6 Two 34
* 1M 24 14 8
20380 21205
2970 1510 1560 430 260 2000 27600 26%5
165 Octet
72 20
86 70 15760 14660 251.3
B 4 72 66 33 0 34 70 14 700
A
6 Two 3 4
34 14' 24 14 812
22250 23075
2970 1510 1890
430 260 2300 30100 29465
180 Odeler
78 18
110 88 18140 1658.8 245.2
H A 78 60 32 5 38 60 12 600 H
6 Two 3 M
4 \\i 24 2 84
25480 26505
3170 1700 1705
725 335 2800 34215 33770
200 OCLER
78 20
110 88 2015.9 1843.1 272.4
H A 78 66 35 75 38 70 12 700 M
6 Two 4
H 1U 2.4 2 84
27900 28925
3170 1700 2065 725 335 3300 37495 37050
Extras and Changes
Four Wall Plaies and Rollers . Four Buck Bars and Cross Rods Two Rear Diamond Washers with Rods
re-door Arch Liners
. pounds . pounds . pounds
pounds
500 .
DO
250 i 475 `
With 3 Vi-inch lubes this boiler has two 3-inch safely valves
500 500 500 ! 500 500 500
575 | 630 i 630
750
750
750
260 250 | 260 ! 250 260 280
475 ! 475 475 475 475 475
tAll openings over 3 inches will be forged sieel flanged nozzles.
500
800 260 500
500 800
280 500
Kewanee, hi-test Series HT
Specifications--
BOILER NUMBER....................................................................
............................. HT 50 HT 60 HT 75 HT 100 HT 125 HT 150/
HORSEPOWER
STEAM RADIATION-HAND FIRED ...............
-MECHANICALLY FIREO ...................
HEATING SURFACE ............................................................
GRATE AREA OR PLAN AREA
.............................................................
FURNACE VOLUME............................................
... . SQ. FT. . . SQ. FT.
....... SQ.FT. . . SQ. FT. .......... CU. FT.
50 7000 8500 500 18.3
72
60 8400 10200 600 20.3
90
75 10500 12750
750 22.5 105
100 14000 17000
1000 27.5 140
125 17500 21250 1250
30.2 181
150 21000 25500
1500 35.7 213
<
FURNACE WIDTH.............................................................................................. .................... IN.
LENGTH......................................................
.........IN.
48 55
48 61
53 61
59 67
65 67
65 79i/2
'lb
HEIGHT ABOVE GRATES ...................
. IN.
40
46
46
50
60
60
CYLINDER DIAMETER. FRONT................................................................... REAR '............................
...IN.
42
42
42
48
54
54
. IN.
66
66
72
78
84
84
BOILER LENGTH OVERALL
...................................................................
BOILER HEIGHT. FLOOR TO TOP OF SHELL ....
WATER LINE HEIGHT .
.............................
FT. IN. IN. IN.
12-5 107 95
13-5 113 101
14-3 113 101
15-5 125 110
16-2 142 124
18-6 142 124
STEAM SUPPLY SIZE..............
.............................................
BLOW-OFF SIZE
... .............................
FEED WATER SIZE
............................................
INJECTOR SUPPLY SIZE
..
SAFETY VALVE NO. AND SIZE-125 LB. ISO LB.
...
SIZE MAY VARY WITH SET PRESSURE OF VALVE.
BREECHING DIAMETER.........................................
STACK DIAMETER ..................................................................
STACK HEIGHT-HAND FIRED.................................
.............
STACK HEIGHT--MECHANICALLY FIRED.........................
BREECHING DIAMETER. TWO BOILERS....................................
STACK DIAMETER,
TWO BOILERS ......................................
STACK HEIGHT.
TWO BOILERS. HAND FIRED
STACK HEIGHT.
TWO BOILERS. MECHANICALLY FIRED
. . IN. IN. IN
. . IN
IN. . IN.
IN. IN. FT. FT.
IN. IN. FT. FT
4 2 1`/< 1
2-214 2-2*4
24 22 55 45
31 29 65 55
4 2 1*4 1
2-2i/2 2-21/2
26 24 60 50
34 32 70 60
4 2 P/2
1*/
2-3 2-3
5 2 11/2 1'/<
2-3 2-3
29 31 27 29 65 . 70 55 60
38 41 36 38 75 80 65 70
6 2*4 1V2 1*4
2-3 2-3
33
31 75 65
44
41 85 75
6 2*4 1*4 1*4
2-3 2-3
36 34 80 70
48 45 90 80
FIREBRICK 9 IN. WALL. ABOVE BASE LINE . .
COMMON BRICK IN BASE AND PIER
2 IN. INSULATION LINING..............................................
OUTSIDE SURFACE TO COVER
..........................
NUMBER NUMBER
SQ. FT. SQ. FT.
1300 650 130
115
1450 700
155 145
1700 800
160 165
2050 1000
195 200
2450 1150 225 250
2600 1200 250 300
APPROX. SHIPPING WEIGHT
BOILER. HAND-FIRED.
125 LB. . ..
150 LB.. .
MECHANICALLY-FIRED. 125 LB...................
150 LB.
FURNACE REFRACTORY & INSULATION........................................
LB. 13660 LB. 13760
LB. 12620
LB. 12720 LB. 10150
15380
15580 14230 14430 10750
18870
19270 17580 17980 13250
22920 23420 21270 21770
16550
26720 27420 24850 25550 18700
30200 30900 28220 28920 19400
CODE WORD. STEAM BOILER-125 LB. W.P. -150 LB. W P...................................
HTETF HTETG HTETH HTETI HTEFF HTEFG HTEFH HTEFI
HTETJ HTETK HTEFJ HTEFK
i
**For Oil, Gas or Stoker, add word to code; example--ship one HTETF OIL. Series 30 Nozzles for 250 lb. cast-iron or 300 lb. steel fittings. Steam supply and blow-off sizes given are openings regularly found on boilers in stock.
EQUIPMENT -- Flue Gas Chambers -- Rear, with Lining, insulated Doors and Frame; Front, with Doors and Frame; Damper in' Outlet; Rear and Center Saddles; Steel Casing extending to top of base with front.
Coal Hand Fired--Fire and Ash Doors; Dead Plate, Stationary Grates; or Shaking, Semi or Full Dumping assemblies at extra cost.
FIRE TOOLS for Coal--Hoe, Poker, Slice Bar, Flue Cleaner with handle.
IRE TOOLS for Oil, Gas, Stoker--Flue Cleaner .rly with handle.
Full Metal Bases can be furnished at additional cost. Boiler may be shipped on skids; no Refractory Fire box Lining included.
TRIMMINGS for Coal, Stoker, Oil, Gas--Steam Gauge with Syphon and Cock; extra heavy cast iron Water Column with Water Gauge and Gauge Cocks, Compression Try Cocks; Safety Valves as required by A.S.M.E. Code; Blow-off Valve and Cock; Globe and Check Valve for feed pipe.
No other accessories or piping.
Special trimmings furnished at additional cost.
23
KtWANtS, Return Tube SCOTCH MARINE BOILER
SPECIFICATIONS
NEW 100 Lb. SteamA. S. M. E. CODE
NEW High Pressure Steam
Boiler N umber.
Rating. Mechanical-Fired -- Horsepower ---Thousands of Btu per Hour --Pounds of Steam per Hour
Racing. Hand-Fired -- Horsepower --Thousands of Btu per Hour
-- Pounds of Steam per Hour
Heating Surface
Grate Area Furnace Volume
sq ft. sq ft cu ft
K--Shell Diameter
L--
Length . .
H -- Furnace Diameter
J--Grate Length.
in.
i n. i n. :n
Steam Supply Size Biow-olT Size Safety Valve Sue --
Coal, han d- fi re d
Oil or Gas . . Stoker
.n :n
in
HM6 HM9 HMl 5 HM20
7 12 16 24 234 i 400 600 800 242 : 410 620 B30
G j 9-9 200 ! 331 207 342
60 ' 99 3-5 4 15-5 24-1
42 48 61 63 21 24 24 24
22 1 '/* 1 Vi
3i 1 1 Vi 1%
15 500 520
150 6
29 4
48 84 24 36
2 1 7*
1 Vi 2
1 7,
20 670 690
200 8
34-S
48 105 24 48
2 1 '/*
1 7: 2
2
HM25 H M 30
30 1020 1050
36 1200 1240
25 840 865
250 10 47-3
54 105 28 54
2 1 Vi
30 1020 1050
300 12
S3 1
54 122 28 60
3 1
2 2'5
2 '-i 2 2 1 ? ___ 2 _
Fire Door Opg. Width Height
Ash Door Opg Wdt x Hg
Ereeching Diameter Stack Diameter . .
Heicht . .
; n 15
16 16 16
10 11 11 11
i n 15x1'/. 16*6'/:16*6V:iex6V:
n 14 i n. 12 ft 30
16 17 19
14 15 17 3* 40 40
1R 18 12 12 18*7 '-x 18*7 w:
20 22 18 20 40 45
Outside Surface to Cover
sq ft. 57
Shipping Weight--On Skid s with
Regular Fixtures, less Sta ck lbs 3700
67 90 11 1 4800 6300 7000
125 145 7800 8500
Boiler Number
H MG
A -- Boiler Width Overall
.n. 47
B -- Length. Overall, hand-fired in 77 V:
BB--
--oil-gas
in. 82 V;
C--Height Overall Shell
54 V:
i D -- Water Line
in. 46V:
E -- Water Column Height. EE--Height from Bcile' CL F -- Steam Supply Location G--Safrtv Valve Location
M -- Ereeching Connection
N--
Location
O--
Height
P -- C'earance Beneath Shell 0 -- Legs Location R -- Skids Location
. i n 44 7: 1 1 74
i n 13 15
. i n 24 i n 5 7: i n 44 Vi
i n 12 : n. 38 7: i n 37 7:
Plate Th-ckness -- Shell -- Heads
-- Furnace
in. in
Re;..rn T-brs-- Number
-- Diameter -- Length
n in
St-rl Srm.Ke Stack -- Gauge No
at ex'ra cost --Diame'er i n
-- Lengt h
in
-- Weight lbs
7*
Vi
16 3 40
14 12 30 350
HM9 HM15 HM20j HM25 HM30
53 80 84 7j
62
53 53 i
101 122
105 7: 62
126 7: 62
i
59 123
127 67 7:
59 140
144 67 7:
53
51 13 74
14 15
53
51 13 74
18 15
53 1
51 13 7*
24 16 7:
j ,
57 V:
55 7: 15 18
22'A
57 V:
55 7: 15 24
16 7*
30 30 30 j 38 38 6 6 6 1 7/; 7 7: 00 50 50 ! 54 V: 54 7:
13 74 13 74 39 7: 43 42 42
13 7* 61 42
13 13 60 77 45 45
J14 >1* Vis i VS* VS*
'i* Vu
Vi 7. 7i*
''-D
28 28 28
333 42 63 84
3G 36
33 83 100
14 14 14 1 12 12
14 15 17
18 20
35 450
40 550
40 650
1
j ;
40 1000
45 1200
'UIPMENT -- A:i Bo irrs mounted or. s* ids; equipped with Handholes Ma-.h-ilf .n 5 -t' bo ier s only. Smokebox *'ith Damper. Insulated Flue Doors; Refractory .d rear Combustion Cham.ber. Rear Er.d Plate with cleanout door. 4 * Fusible Plug Socket Wrench. Flue Scraper with handle
. RIMMINCS-All St earn. Eoders Ca* t I -on Water Column w it h standard Gauge Glass Cocks Gauge Glass. Guards, three Try cocks. Steam Gauge. Syphon nd
Cock; Safety Valve,
Fr-.brrtby Ir.;e:-cr. Blow off Valve. P-pmg and F -gs fer attaching tr-mmings to boiler
No tnmmings fjrmsrcd w not water bc.lers No mechanical fir.r.g ec- ;m.rr-* mcluded and no damper i n smokebox out let
COAL Hand - Fi r cd -- C a ' t m F urn a :e 'rcr.t wt h Firedocr and L -er As*- D w R at c net Draft door Stationary Grates ar. d Support Refractory Bridgewall,
Hoe, Poker OIL or CAS Fired --Stee. F .rr.acr rrr.vtn w-.th co-.crplate and p--pr.-> STOKER F > r e d -- Fu r nare Front with doors NOT furnished by K. B. Corp.
24
6
cI N* i* ? i
l
L
25
CO
o
m
p
AI PM EH CO
B
p
CO
pm
3
CO (H O
o
CO CJ
1
Sa pa
26
//
Kewanee Residence Type R Boiler
>
Type R Steel Boiler is a later Kewanee develop
ment employing characteristically sound steel con
struction in the compacted style of heating unit.
11 is designed to serve the smaller kind of building--
such as garage, store, school, church, apart ent,
office or residence.
Every kind of solid fuel, coke, all grades or soft
or hard coals and their briquette or powdered
forms are burned with excellent success, also any
liquid fuel oils, and natural or commercial gas
can be used with high efficiency in Kewanee Type
R Boilers. Provision is made so that Kewanee Indirect Hot Water Heating Coils may be applied in any sizes.
FRONT FIRD
UAH flKID
Sections Showing Type R Oil Burning Boiler Settings--Front or Rear Fired
Data and Measurements. Nos. 740 to 748--For Bituminous Coal. 2740 to 2748--Anthracite. 1740 to 1748--Oil, Gas or Stoker
Number of Boiler........................
43740-2740
Sq. Ft. Sq. Ft. Sq. Ft. Sq. Ft.
Length of Boiler........................... Size of Keturn'lnlet added for
Water......................................... .Inches Size of Safety Valve Opening.. . .Inches Size of Steam or Water Outlet.. . Inches Size of Steam Return Inlet........
Resam Ruaam
430 690 44 3.0 31 27 H
2)4 I 3
2)4
A--Overall Height. Floor to
Top of Shell............................... B--Height of Water-line............
Chimney--Diameter............ Chimney--Height................ ... Feet Breeching Diameter............. . Inches Breeching Connection Size.
P*Q....... ............................. Inches C--Height of End breeching
Connection Center................... . Inches D--Back of Boiler to End
Breeching Connection............. E--Ht. Breeching Connection. . Inches h--Back of boiler to l op
Breeching Connection Center Inches
59)4 48 12 35 14
8)4x17
49)4
17)4 HH
M34
G--Steam or Water Outlet Center to Boiler Front..........
H--Ht. of Return Inlet Centers Inches Heater Connection Size. . . .Inches
O--Return Inlet Offset from Boiler Center............................
1--Heater Connection Center
from Back of Boiler.............. .Inches J--Heater Connection Height
from Floor.............................. .Inches
L--Length of Base.................... M--Width of Base.................... .Inches
M 15 34 2
5
6M
43 H 12 31)4 30
Outside Surface to Cover. Sq. Ft.
Approximate Weight................. Pounds
33 1700
1740
Rated Capacity. Steam........... Sq. Ft.
Cu. Ft.
Approximate Weight
Pounds
450 6.6 1540
*For Jacketed Boiler, add l J^-inch to overall height.
! 741-2741
Resay Rusty
590 940 54 3.9 31 3334
2)4 1 3 234
742-2742
Rescu Ruacu
790 1260 63 4.8 31 39)4
2)4 1)4 4 2)4
743-2743
Reset Ruset
1000 1600 73 5.6 31 45M
2)4 1X 4 2H
745-2745
Resew Rusew
1350 2160 101 6.7
31 4534
4 IM 5 3
746-2746
Resin Rusin
1600 2560 114 7.8
31 5134
4 lM 6 3
747-2747
Resoi Kutol
1780 2850 127 6.8
3! 5734
4 134 6 3
59M 48 12 35 14
8K*I7
49 >A
17)4 55)4
IIH
5934 48 12 35 14
8M*I7
49 M
1734 55)4
UK
59M 48 12 35 14
8)4x17
49 >4
1734 55 34
1134
7034 5834 16 40 18
11x22
54
20 6134
1234
7034 5834 16 40 16
11x22
54
20 6134
1234
7034 5834 16 40 18
11x22
54
20 6134
1234
11 II II
12 12 12
15 X
15)4
1534
16
16
16
2 22
222
555
66 6
6)4
43 K 12 37H 30
6M
43 H 12 43H 30
634
43 34 12 4934 30
634
5434 12 4934 34
634
5434 12 5534 34
634
5434 12 6134 34
38 1900
43 2150
48 2360
60 2800
66 3050
71 3300
1741 Rosay
620
8.8 1680
1742
840 10.9 1900
1743
1120 13.0 2060
1745
1470 16.5 2500
1746
1900 19.0 2730
1747
2160 21.6 2920
For Water, add word to code; example: Ship today one RESCU WATER complete.
7413-2748 Rest Rust I960 3140 140 9.9 31 6334
4 2 6 3
70)4 58)3 16 40 18
11x22
54
20 61)4
234
12 16 2
6
6)4
5434 12 67)4 34
77 3550 1746
2380 24.2 3120
TMt Plumimf anJ Httling Calalot 8
"83R" Series Square Boilers Oil, Gas or Stoker
Squar* Jacketed Type "R** Steel Boiler
DATA AND MEASUREMENTS.
63R1-63R4 with Tapered Sides, 03R6-S3R9 have Straight Sides
Boiler Number............................... Oil or Gas 83RI Stoker OS3RI
Rated Capacity--Steam.....................Sq. Ft. Water.................So Ft Btu. per Hour....... 1000's
901 1441 216
Heating Surface...................................Sq. Ft Net Furnace Volume.......................... Cu. Ft.
53 6.6
Width Boiler Overall.................................. In.
A--Height Boiler Overall.......................... In.
Shell Leneth Overall.............................In.
Firebox Height.............................
In
Addn'I. Furnace Height for Stoker**.In.
Firebox Width........................................ In.
Firebox Length.....................................In
*B--Water Line Height.............................. In.
32* 60 * 27*
21 4
21* 20
46
C--Smoke Outlet End. Height............... In. E--Smokehood Length......................... In. G--Steam Supply Location........................In
H--Return Height.......................................In. I--Heater Connection Location................In.
J--Heater Connection Location.............. .In. K and M--Base Height*'* x Width .... In. L--Base Length...........................................In.
*9M 16
I2H
HH 7X 3K 12.30 3134
O--Return Location................................... In. P--Breeching Connection Width.............In Q--Breeching Connection Length........... In
4--Boiler to Smoke Outlet Center......... In 5--Smoke Outlet Too. Height............. In
Regel Jacket Overall 33 Vi wide. Length In.
4
9H ii'i 5934
Steam Supply Size, or Water.....................In. Steam Return Size....................................... In. Added Return for Water............................ In. Safety Valve Size...................................... In. Heater Connection Size.............................. In. Chimney Diameter x Height.......... In. x Ft
Breeching Diameter................................... In.
4 234 234 '1
10x35 12
Outside Surface to Cover. Unjacketed.Sq.Ft
33
Shipping Weight. Jacketed ...................Lbs. 1600
83R2 083 R2
1105 1768 265
65 8.6 32* 60* 33^
2l 4 21* 26 48
4934 16
1234 1534 7 Vi 43 H 12x30 3734
4
9H 55 54 65>4
4
11x35 13 38
1600
83R3 083R3
1326 2121
318
76 10.9
3234 6054 3934
21
si
48
4934 16
1254 '5)4 7 Vi 43*4 12x30 43 54
4
9 54 55* 71*
4 234 234 '1
12x35 14 43
2000
83 R4 63R6 83R7 083R4 083 R6 083R7
1513 2420 363
2UVI
3345 502
2363 3780
567
89 13.0
123 16.5
139 19.0
32* 60* 45*
21 4
21* 38 46
,
32
21)4 45)4
24 6
25)4 38
58)4
32
71* 51*
24 6 25* 44 58*
49* 16
12* 15*
7* 43* 12x30 49*
54 18* 13*
16
7* 54* 12x34 49*
54 18)4 1354
16
7 Vi 54)4 12x34 55)4
4
9 54 55 >4
77)4
6 II 22 II 61*
6 II 22 11
61*
4 56 234 3 3 2)4 4 4
'1'1 '1
12x40 14x40 14x40 14 16 16
48 2200
60 1 66 2800 1 2900
83 R8 OS3R8
2652 4243
637
156 21.6
32 71* *7H
6
2Ts
58)4 54
18)4 1354
16 7 Vi 54)4 12x34 61 H
6 11 22 11 61*
b 3 4 2 2 15x45 17
71 3100
83 R9 OB3R9
2924 4678
702
172 24.2
32 71* 63*
24 6 25* 56 5B*
54 18* 13*
16 7* 54* 12x34 67*
6 II 22 II 61*
6 3 4 2 2 16x50 18
77 3300
For 63R1 to 4 sizes, raise Water Line to 49" for Single Coil; 30" for Double Coil or Inataotaneous Coil. For 63R6 to 9 sizes, raise Water Line to 39" for Double Coil or Instantaneous Coil.
'When higher bases are used, height of Water Line B--is increased, also dimensions A--C--H--J--K--S--.
"Additional Height bases up to 21" furnished without extra cost. For Stoker. Firedoor with air slots and baffle plate replaces Oil-Cas refractory insulated door with peephole.
Also 1742*3, and CA-2R1-2-3-4.
Kewanee 83R Series is a Jacketed
Square Type"R" Residence Boiler, of
substantial steel construction, especial
ly proportioned for Oil. Gas or Stoker,
retaining in all respects the Kewanee
standard of Quality.
83R conforms to construction Code of AS.M.E.
Has 2-pass tubes; with spinner blades for Oil-Gas; two-way draft adjuster; all steel base of new and improved design.
Covered Coil Box in front head for Kcwanec Copper Coils of any capacity for Storage Tank Hot Water or Instantaneous Flow without Tank. Incinerator grates can be installed in larger size*.
Stack Control Opening is provided in Rear Hood and in Front Smokcbox Frame. Tapped openings either side of Boiler Shell can be used for Aquastat. There are plenty washout plugs in shell, and knockout discs in Jackets opposite all Boiler openings. All Jacketed Kewanee Boilers have indestructible baked enamel steel Jacket, with insulation lining nr blanket.
Kewanee Indirect Hot Water Heating Coils Maximum Length in Each Boiler
Kewanee Hot Water Coil for Storage Tank S6-24 means Single row 6 pipes 24" long.
D0-6O means Double rows 6 pipes 60* long
Boiler ratings do not include allowances for heat*
ing domestic hot water with Indirect Coils.
All Coil capacity ratings are with Boiler Water at steaming temperature. For summer use, and intermittently fired fuels, use capacity listed with 160* Boiler ^ater.
For GRAVITY CIRCULATION with STORAGE TANK, capacity listed is the number of gallons raised 100* in 3boure. Allow * sq.ft, of steam radiation for each gallon capacity.
For INSTANTANEOUS TANKLESS PERFORMANCE, Coil for Instantaneous Flow without Tank capacity listed is the number of gallons raised 100* in 1 hour. TNf-Triple rows of pipes for 63R Boilers.
SAllow 4 sq. ft. of steam radiation for each gallon capacity. NI-QN9Quadruple rows of pipes. 83R Boilers.
except no allowance is required when water heating demand is NI-DN9 Double rows for Sq. "R" Boilers. less than 10 minutes in eny hour.
For Storage Tank Operation
For Instantaneous Flow
For Storage Tank Operation
For Instantaneous Flow
Boiler No.
742
742 742 43; 773. 745 746. 774 747. 775 748 776 to 790
Coil No.
S6-24 58-24 D6-24 D8-24
D8-30 D8-36
D6-42 D8-48 D6-54
D6-60 D6-66 D6-I20
Rated Capacity CaJs. Heated
40*-140 3 Hrs.
in Boiler Water
212" F. 180" F.
90 55 120 70 180 MO 240 145
320 190
400 240
460 290
560 335
640 385
720 430
600 1520
480 910
Boiler No.
742
Rated Capacity
Cals. Heated
Coil No.
40"-140" in 180" Boiler Water
1 Hr. 1 Min.
DNI 185 3.1
742 742 743: 773. 745 746. 774 747. 775 748. 776
DN2 DN3 DN4 DN7 DNS DN9
240 295 350 400 450 510
Larger sizes on application
4.0 4.9 5.8 6.7 7.5 0.5
Boiler No.
83RI
83R2 83R3 63R4.63R6 83R7 83R8 83R9
Coil No.
SL6-24 S L6-24 DL6-24 DLS-24
DL8-30 DL8-36 DL8-42 DUMB DL6-54 DL8-60
Rated Capacity Cals. Heated
40"-140* 3 Hrs. in Boiler Water
212* F.
90 120 160 240
180 F
55 70 no 145
320 190
400 240
460 290
560 335
640 385
720 430
Boiler No.
Rated Capacity GaJs. Heated
Coil 40*-140* in 160* No. Boiler Water
1 Hr. 1 Min.
83RI
TN-1 165 3. 1 QN-1 240 4.0
83R2
QN-2 310
5.2
83R3
QN-3 375
6.3
63R4.63R6 QN-4 445
7.4
83R7 QN-7 510 6.5
83R6 QN-6 560 9.7
83R9
QN-9 650 10.8
For larger volume, two Storage Tank Coils may be installed in some boilers.
K*n Cttihg Ns. SO k.
29
Kewanee Type C Electric-Weld Boiler
The Kewanee Type C Boiler exemplifies the latest in expert thought. 11 is built of steel plate, seven simple shapes, solidly welded into a homo geneous unit by the well proven electric metallicarc-puddling process same as has been used on welded details of Kewanee Boilers for years, and it has the Patent Corrugated Crown Sheet.
This Boiler is built to the A. S. M. E. Code for low pressure heating boilers. It is a real boiler in construction--a scientifically designed steam generator.
Type "C" Boilers may be fitted at factory with Kewanee Indirect Hot Water Heating Coils at extra cost.
i
L4 (Mid m
\!
I TVs Wall CNamtd
LONCrTVSOUL BCT10M
FOUNDATION H.AM
Specifications--No*. 749-770 for Bituminous Coal.
Nos. 2749-2770 for Anthracite Coat.
Nos. 1749-1770 for Oil, Cas or Stoker
Number of Boilers........
749 >51 2749 2750 2/ 51
Hi
2752
aHni
Ha 2754
Hi
2755
756 2756
757 2757
Jis 2758
--m 2759 2760
?6I 2761
762 hi 2762 2 763
764 765 766 "767 766 769 T7o
2764 2765 2766 2767 2768 2769 2770
Capacity. Steam .Sq.Ft. 2300 2690 3250 3630 4060 4550 5250 5950 6470 7000 8280 9610 10650 12110 14300 16360 18660 20750 22520 25530 28780 33070 Heating Surface..Sq.Ft. 164 192 232 262 290 325 375 425 462 500 591 686 775 865 1025 1170 1333 1482 1608 1824 2056 2362 Area of Grate... .Sq.Ft. 9. 1 10.3 11.0 f 1.6 12.4 13.9 15.5 18.0 19.7 21.5 22.4 24.3 24.7 26.9 27.6 30.1 32.9 35.6 36.0 38.9 42.1 45.2
Diameter of Stack.. . In. 16 20 20 20 22 22 22 24 24 26 26 26 30 30 32 32 34 34 38 38 40 40
Min. Fit. of Stack. . . Ft. 45 50 50 55 55 55 60 55 60 65 65 65 70 70 70 70 80 90 90 90 100 100
Dia. Stack. 2 Boilers.In. 26 Min. Fleight of Stack.
26
26 26 31
31
31
34
34 36
36
40 42
42
46
46 48
48 52 54 54 54
Two Boilers.......... Ft. 55 60 60 65 65 65 70 65 70 75 75 75 80 80 80 60 90 100 100 100 no 110 Size Steam Opening, in. 6 6 6 6 6 6 6 6 8 8 8 6 6 6 8 6 8 8 8 10 10 10 Size of Ket. Opening. In. 4 4 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 Size of Safety Valve
Opening.................In. 2 2 2 2 2 2 2) 2! 3 3 3 3* 3* 3* 3! 4 4 2-2* 2-2* 2-3 2-3 2-3
A--Width of Boiler..In. 36 36 36 36 42 42 42 48 48 48 54 54 60 60 66 66 7? 72 78 78 64 64
B--Lgth. Boiler. Ft. In. 4-2 G--Overall Length of
4-8
5-6 6-4 5-10* 6-6* 7-6
7-2! 7-10 8-5
7-5* 8-7
8-0* 8-11 9-7 10-10 9-10} 10-11 10-10 12-2* 10-11 12-5
boiler.............. Ft. In. 5-10 6-4 7-4 6-0 7-10* 8-6* 9-6 9-4* 10-0 10-7 9-8* 10-10 10-4* L)--Ov all Ht. Boiler.In. 771 77! 77* 77! 83! 83! 83* 66* 86* 66* 99 99 toe*
Ffc.-----WHti.dAthsho-fpCitrBataesse.In. 14 14 14 14 14 14- 14 >4 14 14 14 14 17
11-3 11-11 108* 112
17 17
13-2 12-8* 13-9 13-8 15-0* 13-9 15-3 M2 118 118 122 122 135 135
17 17 17 17 17 21 21
and Aah-pit.......... In. 30 G--Lgth. of Grate*. In. 43 H--Height of Front
30 49
30 56
30 56
36 50
36 56
36 62
42 62
42 68
42 74
47* 47* 52* 52* 58* 58* 65 68 74 68 74 68 74 74
65 60
70 74
70 80
76 80
76 86
Smokebox............. In. 34 34 34 34 34 34 34 35 35 35 42 --Top Fr. Smoke-bos
42 48
48
48
48 51
51
52 52 61
6!
to 1 op of Boiler , .In. 10 10 10 10 13 13 13 14 14 14 16 16 16 16 18 18 17 17 19 19 21 21 J--Depth of Front
K--SmDoekpetbhooxf...R...e..a..r....In. 9 9 9 9 10 10 10 11 II 11 12 12 12 12 12 12 14 14 14 14 14 14
Smokebox..............In. II 11 II 11 14 14 14 15 15 15 15 15 16 16 16 16 20 70 20 20 20 20
L--Ht. KcarSmkbx . In. 26 26 26 26 29 29 29 31! 31! 31! 35 35 36 36 39 39 43 43 45* 45* 49* 49*
M--Dia .Smoke Outl.In. 20 22 22 22 24 24 N--Height Smoke Out-
24 26 26 26 28
26 32
32
34
34 36 36 40 40 42
42
let above Floor. . .In. 641 64! 64* 64* 69 69 69 70 70 70 81* 81* 90* 90* 93 93 96 96 99 99 110 110
O--Ht. WaterCol... In.. 651 65! 65! 65* 68 66 68 70 70 70 81 81 90 90 92 92 97* 97* 99* 99* 1 10* 110* F*--Ht. Water L-ine.. In. 69 69 69 69 72 72 n 73 73 73 85 85 94 94 95 95 101 101 103 101 114 114 Q--Ht. Steam Sup.. In. 79! 79! 79! 79! 85! 85* 85! 88* 88! 88* 101 101 no* 110* 114 114 120 120 124 124 137 137 K--Ht. of Return. ..In. 16 16 16 (6 16 18 16 19 19 19 19 19 22 22 22 22 22 22 22 22 26 26 S--Location of Steam
Supply.................. In. 10! 14 14 16 14 16 18 18 18 18 18 21 18 21
18 21 21 21 21 2! 21 24
T--1st Safety Valve . In. 8! 10 10 10 10 to
l
14
14
14
13
14
13
14
13
14
14
14 14 10 10
14 11
1| 4]
15
V--Surface Blow-off In. 12 12 12 12 12 12 12 12 12 12 18 24 24 24 24 24 24 24 24 24 24 24
W--Width of Base In 41! 41! 41! 41! 47! 47! 47* 53! 53* 53! 59* 59* 66 66 72 72 78 78 84 64 90* 90* X--Width of Found . In. 46 46 46 46 52 52 52 58 58 58 63* 83* 68* 66* 74* 74* 80 80 86 86 92 92 Y--Lgth. of Found. . In. 53* 59* 71'4 60 74! 82* 94 90 97* 104* 93* 707 100* 111 119 134 122* 135 134 150* 13S 153 Z--Lgth. of Ash-pit.-In. 37! 43! 51 51 45 51 57 57 63 69 63 69 64 70 64 70 70 76* 70 76* 76* 82} Outside Surface to
Cover.............. Sq. Ft. 62 66 60 89 93 102 115 119 126 136 145 165 172 187 210 234 231 252 265 294 294 328
Approx. Weight.Rounds 4300 4700 5200 5500 6000 6500 7100 7500 7900 8300 10600 II700 12900 14000 16300 17900 19800 21300 22600 24700 58400 31300
No. of Oil Burn Boiler.. 1749 1750 1751 1752 1753 1754 1755 1756 1757 1756 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 Capacity. Steam Sq.F t. 2790 3260 394C 4450 493C 5520 6370 7220 7850 8500 10040 11670 13180 14700 17420 19880 22650 25200 27300 31000 34900 40150 Furnace Volume.Cu. Ft. 24.0 26.6 31.1 35.7 44.C 47.6 52. 1 63.5 69 I 74.5 86 7 % C 113.1 124.8 151 1 168.6 185.9 201 0 230.6 256.0 275.7 309.6 Approx. Weight. . ..lbs. 3600 3600 4200 4600 5000 5 400 5900 6300 6700 7100 6800 9600 10600 11500 13700 I5f00 (6600 17600 19200 21100 24300 27000
Rated Capacity for Water Boiler is 60% Greater than Steam.
Manhole on No*. 759. 2759, 1759 and larger.
<
i
The Plumbing and Htaling Catalog 30
KE.WANEE. Type "C" Welded Boiler
-- For Coal
This Type "C" is a welded com
pact boiler. Its corrugated crown
sheet has much greater strength
and adds more heating surface
where most effective use may be
made of intense heat for quick
steaming.
T"CLJan OUT
Boilers 774-790 with smokeless arch
and drum are for use with high-volatile
bituminous coal; Nos. 2773-2790 without arch are direct draft for use with smokeless fuels such as low-volatile bituminous coal,
FRONT ELEVATION
'LOON LINE
coke or anthracite.
Equipment--Steel base fully assembled
Typa 4,C" Welded with heavy rocking (or dumping) grates and
Boiler with Three cast iron ash pit front, f )ur cast iron corner
Inch Tubes.
posts, heavy steel Banged panels with rear
cleanout opening except 36" boilers; refractory
bridgewall and header wall; insulated Bue
door; firedoor with liner; smokebox soot clean
out doors. Type"C" may be fitted at factory
with Kewanee indirect hot water heating coils
1 Vj EXCEPT36' eocuees
NOTE i 1 LONGITUDINAL SECTION
at extra cost. Firing Tools--Hoe, poker, slice bar and flue
cleaner and handle.
Trimmings for Steam Only--Safety valve, steam gauge with syphon and cock; draft reg ulator; water column with water gauge, glass and cocks.
FOUNDATION PLAN
Footings may be required under base corner posts depending on soil conditions.
All front smokeboxes have double doors.
Note I. Manhole furnished on boilers 782, 2782, 1782. 0782 and larger.
Note 2. Bridgewall omitted on boilers 2773; 774. 2774; 775, 2775.
Type**C'* conforms to the A.S.M.E. boiler construction code for 15 lbs., and for rating with the S.H.B.I. simplified practice recom mendation.
Specifications and Setting Measurements
Boiler Number.............. With Arch
774 775 776 777 778 779 "TSo 781
W'ithout Arch 2773 2774 2775 2776 2777 2778 2779 2780 2781
Ratine--Steam Radiation.........Sq. Ft. 2200 2600 3000 3500 4000 4500 5000 6000 7000
Water Radiation........ Sq. Ft. 3520 4160 4800 5600 6400 7200 8000 9600 11200
Btu. per Hour
1000's 528 624 720 840 960 1080 1200 1440 1680
Heating Surface (S H B 1 mm.) Sq. Ft. 158 186 215 250 266 322 358 429 500 (urate Area SHB1 min.:. . . . Sq Ft. 8.9 9 7 10.5 II.4 12 2 13 4 14.5 16.4 18.1
Breeching Diameter...........................In.
19 19 19 19 22 22 22 24 24
Stack Diameter.................................In.
15 16 16 17 18 19 20 21 22
Stack Height ...
... Ft. <45 50 50 55 55 55 60 60 65
Breeching Diameter. Two Boilers . In. 23 24 24 25 26 27 28 30 31 Stack Diameter. 1 wo Boilers .... In. 21 22 22 23 24 25 26 28 29 Stack Height. Two Boilers.......... Ft. 55 60 60 65 65 65 70 70 75
Steam Supply Size........................... In. 6 6 6 6 6 6 6 8 6
Return Size......................................... In.
333 3 33344
Water Heater Connection Size .... In. 2 2 2 .2 3 3 3 3 3
Safety Valve Size .........................In.
2 2 2 2 2 2/ 2/ 2/
3900
5000 5500 6000 6500 7500 6400
2700 Series . . . Lb. 3*00 3800 4300 4800 5300 5600 6300 7200 8100
A--Boiler Width...............................In. 36 36 "36 ^"36 42 42 ---- 42 48 48
b -- Boiler Length .....................Ft. In. 4-2 4-8 5-2j 6-0 V* 5-10} 6-6/ 7-2 7-2/ 8-5
C--Boiler Length Overall........ Ft. In. 5-10} 6-414 6-10} 7-9 7-10} 8-6/ 9-2 9-4/ 10-7
D--Boiler Height Overall.............. In. 77/ 77y> 77/ 77/ 83/ 83/ 83/ 86/ 86/
E--Water Line............
. . In. 69 69 69 69 72 72 72 73 73
782 783 784 785 786 787 788 789 790 2762 2783 2784 2785 2786 2787 2788 2789 2790
8500 10000 12500 15000 17500 20000 25000 30000 35000 13600 16000 20000 24000 26000 32000 40000 48000 56000 2040 2400 3000 3600 4200 4800 6000 7200 6400
608 715 893 1072 1250 1429 1786 2143 2500 20.5 22.5 25.6 28.4 30.9 33.2 37.4 41.2 44.7
28 28 30, 31 35 35 39 41 43 24 26 28 29 31 33 36 38 40 65 70 70 75 75 60 95 95 110
34 36 40 4| 44 47 50 54 56 32 34 37 38 4! 44 47 50 52 75 80 80 85 85 90 105 105 120
6 8 8 8 8 8 10 10 10 4 44 4 446 6 6 33333333 3 3 3 2-2 2-2/ 2-2/ 2-2/ 2-2/ 2-3 2-3
9700 i 1000 12900 14900 16600 18400 22000 25200 28400 9400 10600 12500 14400 16100 17900 21200 24400 27500
$4 54 60 66 --n Ti fS 84 64
7-8 8-11/ 9-2/ 9-11/ 9-3/ 10-6JX 11-11} 11-4/ 13-1/
9-11 ti-2^ 1 1-6/ 12-3/ 12-1/ 13-4/
14-2/ 15- Hj
99 99 108/ 112 118 116 122 135 135
85 65 94 95 101 101 103 114 114
F---Water Column Height............... In. O--Steam Supply Height................ In. H--Smoke Outlet Hgt. above Moor In. J--Steam Supply Location . . ..In.
K--Safety Valve Location ........ In.
L--Second Safety Valve Location. . In.
M--Surface Blow-Off Location ... In
N--Return Height
.In.
O--Firebox and Ash Pit Width. . . . In.
P--Firebox Length ...................... In.
K--hirebox Height........................In.
S--Crete Length.....................
In.
T--Base Width.................................. In.
0--Base L.ength................................. In.
V--Base Height
In.
W--Smuke Outlet Diameter..........In. X--1* ront Smokebox Height ... In Y--Fr. Smkbx. Top to Bcilo^Top In-
AA--Front Smokebox Depth.......... In
BB---Rear Smokebox Depth ..........In-
CC--Rear Smokebox Height ........ In
L)U--'FoundatKjn Width .............. In
fc.L---Foundation Length ............ In
H---- Length ot Ash Pit
In
*Oulside Surfsce to Cover
Sq Ft.
CC x HH -- Fire Door Opening In.
Fire Door Stvle
65 / 79/ 64/ 10/
8/
12 18
30 43'/,
26 43
41*4 52 14
19 34 10
9 1114
26 4fi 53'/, 35!/
63
65/ 79/ 64*4
14
10
65/ 79/ 64M
14
10
65/ 79/ 64/
16
10
68 85/
69 14
10
68 85/
69 16
10
68 85/
69 18
11
12 12 12 12 12 12 18 18 18 16 18 18
30 30 30 36 36 36 49 *4 55/ 66 64 72 79 Jr*
26 26 26 29 29 29 49 55 55 50 56 62
4114 4114 41*4 47 J4 47/ 47/ 58 64 74/ 72/ 80/ 88 14 14 14 14 14 14
19 19 19 22 22 22 34 34 34 34 34 34 10 10 10 13 13 13
9 9 9 10 10 10 ii'/, ii/ ii/ 14 14 14
26 26 26 29 29 29 4fi 48 48 54 54 54 59'/ 65/ 76 74 82 90 4114 47 51 45 51 57
69 76 87 94 103 M2
One 1x16
O ne 1 2x 20
Single Frame and Door
70 70 88/ 88/
70 70 IS 18 14 14
12 12 18 16
42 42 80 94/ 30 30 62 68
53/ 53/ 88/ 103
14 14
24 24 35 35 14 14
11 1 1 15 15 31/ 31/ 60 60 90 IU4/ 57 63
120 137
One 15x23
81 101
81/ 18
81 101 81/ 21
90 110/ 90/
21
92 97/ 114 120 93 96 21 21
13 14 14 14 14 12 15 12
18 24 24 24 24 18 18 21 21 21
47/ 85/
34
68
47/
101 34 74
52/ 103 36 74
58/ 112 38 74
63 104 40 74
59/ 59/ 66 72 78 94 109/ 113 122 114 14 14 17 17 17
26 28 30 31
35
42 42 48 48 51
16 16 16 18 17
12
15 35
65/ 96 63
12
15
35 65/
Ml 69
12 16 36
78/ 114/
70
12
16 39
76/ 123/
70
14
20 43 63 115/ 70
150 172 193 220 223
One 16x30
1 One 16x36
Single Frame and Double Doors
97/
120 96 21
99/ 110/ 110/ 124 137 137 99 110 110 21 21 24
14 14 14 15 10 11 11 12 24 24 24 24 21 22 26 26
65 70 76 76 119 136 128/ 149/ 40 42 42 42 60 80 80 86
78 84 90/ 90/ 129 146 139 160
17 17 21 21
35 39 41 51 52 61 17 19 21
43 61 21
14 20 43
63 130/ 763*
14
20 45/
88 147/ 76/
14
20 49/
94
140/ 76/
14
20 49/
94
161/ 82/
246 292 307 348
Two 15x23
I R&L Single Fr.flt Dr.
'Front smokebox and front head below smokebox NOT included.
SO h
KE.WANE.E. Type "C" Hi-Firebox Welded--7L70 Series ^
For Oil, Gas or Stoker
tBB- ,
-K--hM
.--MANHOLE
STCAM SURRLT SAfCTT v/nvt 1
'tSLjN, OTE 1
The Kewanee Hi-Firebox boiler is built exactly right for stokers. This 7L70 series has long water legs
SUSiBlt PLUG
II WATER LINE -------- 1----------------
- - -- iv/ surface aiow-or
--J-M---J
h soc
^'5 '
providing the necessary height in
firebox to comply with S. H.B. I.
code for stoker firing. Type "C" high operating effi
ciency insures life-long economy
with any Oil. Gas or Stoker equip
ment. 27L70 Series Hi-Firebox is built with grates for hand-fired coal.
Tn C Hl-Flr.box Boll.r with Typical Stoker Attachment.
ONE FIRE DOOR FRAME WITH
OOUBLE DOORS NOS. 7L73-7L76
FRONT ELEVATION
\ l>i' ON 7L73 to 7L83 incl.
7L70 Series conform* to A.S.M.. boiler construction code for 15 Iba.. and for rating with the Industry Standard Practice approved by the Steel Heating Boiler Institute in cooperation with U. S. Department of Commerce Recom mendation R 157.
In the Kewanee Process of Corrugating Type `'C" Crown Sheets not even the slightest reduction in metal thick ness is discernible by micrometer meas urements. *
Note I. Manhole furnished on boil ers 7L82 and larger.
WEIGHT OF aO'LCR SUPPORTED ON FOUR CORNER POSTS OP RASE
FOOTINGS MAY BE REQUIRED DE PENDING ON SOIL CONDITIONS.
IL 4-
~F
FOUNDATION PLAN I------------- 1
Equipment Steel base assembled with four cast iron corner posts, heavy steel flanged panelshave &}$ at 11front and rear opening; insulated flue door; and flue cleaner and handle. 7L70 "C" may be fitted at factory with Kewanee Hot Water Heating Coils at extra cost.
Trimmings for steam onlv: Safety valve, ateam gauge with ayphon and cock; water column
with water gauge, glasa ana cocks.
All front smokeboxes have double doors.
Note 2. Average firebox height, computed by dividing the firebox volume by the plen area, compliea with 5.H.B.I. code when stoker dead plates are located at top of mud ring.
jt.
Specifications and Setting Me
Boiler Number.
7L73 7L74 7L75 7L76 7L77 7L78 7L79 7 LAO 7L6I 7L62 7L83 7L84 7L85 7L86 7L87 7L68 7L89 7L90
Rating--Steam Radiation........ Sq. Ft. Water Radiation........ Sq. Ft.
2680 3160 3650 4250 4280 5050 5640 6800
4860 7770
5470 6080 7290 6500 8750 9720 11660 1360(1
10330 1637(1
12150
15180
I822C
21250
24290 30360 36430 42500
Btu. per Hour...............1000*# 643 758 876 1020 1166 1313 1459 1750 2040 2479 (29l 3643 4373 5100 5830 7286 6743 10200.
Heating Surface (SHBI mn.) .Sq. Ft. 156 186 215 250 286 322 358 429 500 Furnace Volume (SHBI min.)Cu.ht. 19.2 22.6 26. 1 30.4 34.8 39.1 43.5 52.1 60.8
608 73.8
715 893 1072 1250 1429 1786 2143 2500 66.8 108.5 130.2 151.8 173.5 216.9 260.3 303.6
Average Firebox Height. See Note 2.In. Firebox Vol. above Mud Ring Cu. Ft. Plan Area.................................. Sq. Ft.
Breeching Diameter............................ I Stack Diameter.................................... I Stack Height........................................ Ft.
33.9 33 0 25.5 28.3
9.1 10.3
32.3 31.1 11.5
19 16 40
31.4 36. 1 13 6
19 17 45
34.5 45.8 15.9
22 18 40
34.0 50.8 17.9
22 19 45
34.0 56.0 19.8
22 20 50
37.8 73.5 23.4
24 21 50
37.2 85.2 2/.5
24 22 60
42.7 100.5 28.2
28i 24 55
42.4 117.4 33.3
28 26 65
46.5 145.4 37.5
30 28 65
48.5 184.5 45.7
31 29 70
52.4 203.7
46.7
35 31 65
54.7 243.4
53.4
35 33 75
58.2 321.6
66.3
39 36 90
63.5 357.2
67.5
41 36 80
66.6 437.0
78.5
43 40 100
Breeching Diameter. Two Boilers. .In. Stack Diameter. Two Boilers ..... In, Stack Height. Two Boilers.............. Ft
24 25 26 27 28 30 31 22 23 24 25 26 28 29 50 55 50 55 60 60 70
34 32
65
36 34 75
40 37 75
41 38 80
44 41 75
47 50 44 47 65 100
54 56 50 52 90 110
Steam Supply Size............................... In
6 6 6 6 6 668 6
Return Size...........................................In. 3 3 3 3 3 3 3 4 4
Water Heater Connection Size........In.
2 22 2 3 333 3
Safety Valve Site.................................In IH 2 2 - 2 2 2 2M 2M 2M
8 4
3 3
8 8 8 8 8 to 10 10 4 4 4 44666 3 3 3 3 33 3 3 3 2-2 2-2 M 2-2 M 2-2 M 2-2 M 2-3 2-3
Shipping Weight.................................Lb. 3100 3500 3900 4400 4900 5400
A--Bo.l.r WkM,:............................. In. "51 --56 ~~ 36 36 "" T5 42
B--Boiler Length.........................Ft. In. 4-2 4-6 5-2 6-03* 5-101 6-6 M
C--Boiler Length Overall..........Ft. In 5-1 Of 6-4 H 6-IOf 7-9 7-IOf 8-6M
^^Boiler Height Overall.................. In 62 H 82 M 82 M 8
68M 88M
E--Water Line Height.......................In
74 74 74 74 77 77
5800 6700 4i 48
7-2 /-2M 9-2 9--4M 88M 94 M
77 61
7600
48 8-5 io-; 94 M
81
8800 10000 11800 13600 15300 17000 20100 23200 26100
54 $4 --at --s, --ft --ft
------ 5? ------ 54
7-8 8-11M 9-2M 9-1IM 9-3 M I0-6M 11-1 H 11-434 13-134
9-11 108
II-2M 108
M-6M 119M
I2-3M 123
12-IM 131
I3-4H 134
I4-9M 140
I4-2H 15?
15-11* 161
94 94 105 106 114 117 121 136 140
F--Water Column Height.................In. G--Steam Supply Height............... In. H--Smoke Outlet Hgt. above Floor. In.
t--Steam Supply Location................ In. --Safety Valve Location................ In. L--Second Safety Valve Location.. In.
M--Surface Blow-Off Location .... In. N--Retu m Height............................. In
70M 64 34 69 H I OH
834
' 12 18
70M
84 H
69 H
1140
' ' 12 18
70H 84 H 69H
14 10
12 18
70M 84 H 69M
16 i.o
12 18
73 90M
74 14 10
12 18
73 90^
74 16 10
i2 18
73 90M
74 16 II
12 18
78 96 M
78 18 14
12 IS
78 96 M
76 18 14
12 16
90 no 90M
18 13
18 18
90 110 90M 21
14
24 18
101
12IM 10IM
21 14 L2 24 21
103 MOM 113M 117M 13234 13634
125 133 136 142 159 163
104 109 112 117 132 136
21 21 21 21 21 24
14 15
14 12
14 14
14
15
24 24 24 24 24 24
21 21 21 22 26 26
^^Firebex Width...............................In. 30 30 30 30 36 P--Firebox Length..............................In. 4334 49 M 55H 66 64 R--Firebox Height..............................In 31 31 31 31 34
36 36 72 /9M 34 34
42 42 80 94 M
47 M 85 M
47M 101
52M 103
5811M1
36 38 43 43 47 49
65 104 53
65 119 56
70 76 76 136 I28M 14934 60 64 66
T--Base Width.................................... In. U--Bam Length...................................In. V--Base Height................................... In. W--Snake Outlet Diameter............. la.
X--Front Smokebox Height............. In.
4134 52 14 19
34
41 M 58
14
19 34
4IH 64 14
19 34
41 M 743*
14
19 34
47 M 72M
14 22 34
47M SOM
14
22 34
47M 88 14
22 34
53M 88M
14 24
35
53M 103 14 24 33
59M 94 14
28 42
59M I09M
14
28 42
66 113
17
30
48
72 122
17
31
48
78 114
17
35
51
76 129
17
35 51
84 90H 9034
146 139 160
17 21 21
39 41
43
52 61
61
Y--Fr. Smkbox.Top to Boiler Top. .In
10
10 10 13 13 13 14 14 16 16 16 18 17 17 19 21 21
AA-- Front Smokebox Depth.......... In BB--Rear Smokebox Depth............. In CC--Rear Smokebox Height.......... In. DD--Foundation Width....................In. EE--Foundation Length................... In. FF--Bolt Centers in Front Plate.. GG-- Bolt Centers in Front Plate.
HH--Firedoor Height.................... In. --Fircdoor Width........................... I K--Space Between Firedoors .... In.
LL--Hgt. Doors from Bottom Blr. In. MM--Open Firedoor to Boiler . . In.
*Outsidc Surface to Cover Sq. Ft 1
9 1134
26 46
5334 3134
4H
1334 2734
9 MH
59 M
3IH
k I3H 27M
934 9M 20 20 79' 85
9 IIH
26 48 65H 31H 4**
UH 2/M
9M 20
93
9 11M
26 48 76 31M 4 *4 135* 27 M
9M 20
104
10 10 14 14 29 29 54, 54 74 82
37M 37M k
10 10 15 15 55 88
20M 20M
16 125
10 14 29 54 90
37M */.
10 15 5 8
20M
134
11 11 15 15 31M 31M 60 60 90 I04M 43M 43 M k 4 k
H 11 16 16
77 68
22 M 22M
152 170
12 15 35
65 M 96
49 M 4k
11 16 12 8
22M
192
12 15 35
65M Ml
49 M
4k
II 16 12 8
22M
215
12 16 36 70M
II4M 55M
5k
12 20
9 8
26 M
245
12 16 39
76 M I23M 6IM
5k
12 20 15
6
26 M
277
14 20 43 63
msm
67m 5k
12 20 20
8
26M
291
14 20 43 83
I30M 67 M
5k
12 20 20
6 26M
327
14 20
45 M 68
I47M 73 M
5k
15 23 20 10 29M
365
14 20 4934 94
MOM
79M 7k
15 23 26
to
29M
415
14 20 4934 94 16134 7934
7k
15 23 26 10
29M
463
Front smokebox and front head below smokebox IS included.
JCtatfM Ce/aJsf As. $0k. 32
Pressure Gage
J 111
-------- r i
-H 's 1i
y (\
\ v^,j &____ i
1i
\\
' V Return
.Firedoor Openings Furnished on Stoker Hend and Fired Boilers Only
y/
jRatings -- Mechanically Fired -- Oil, Gas or Stoker
Bellsr Number
7U7 7L179 7U80 ?Utl
SBI Rating--Steam --Water --MBtuh
--Steam per hour--212* F.
Sq. Ft. Sq. Ft.
Lb.
5100
$280 1392
1430
6440 10300
1546 1590
7720 12350
1853
1900
9000 14400 2160
2220
SBI Net Rating--Steam --Water --MBtuh
Sq. Ft. Sq. Ft.
5070
8110 1217
5640 9020 1353
6760 10820
1622
7880 12610
1890
Firing Rate--Oil --Gas --Stoker
Gph MBtuh Lb. per hr.
16 2460
218
18 2740 244
22 32B0 291
26 3830 340
Heating Surlace (SBI min)
Furnace Volume (SBI min) Furnace Height (SBI min)
Sq. Ft Cu. Ft
In.
322 39.1
31 tt
358 43.5
3m
429 52.1 32*
500 60.1
34
Firebox Vol. Above Bot. of Water Leg Cu. Ft 49.6
Safety Valve Capacity
Lb. steam per hr. 1969
54.5 2188
66.3 2625
76.1 3060
Firing Rates calculated to develop boiler output of 141.S% of SBI Rating. Based on 150.000 Btu. Oil; 12.000 Btu. Coel.
7UI2
10940 17500 2626 2700
9580 15330 2298
31 4650
412
608 73.8 35*
89.7 3718
7U83
12870 20590
3089 3170
11260 18020
2703
37 5460 485
715 86.8
37*
103.5 4374
7LI84
16070 25710 3857 3960
14060 22500
3376
46 6840 607
893 108.5 40*
127.8 5464
7015
19300 30880 4632 4760
16880 27010
4052
54 8200 729
1072 130.2
43
161.5 6559
7L186
22500 36000 5400 5540
19690 31500
4725
64 9560
850
1250 151.8
46
191.1 7650
71187
25720 41150 6173 6340
22510 36020
5402
73 10920
972
1429 173.5 48*
215.3 8745
7U88
32150 51440 7716
792C
281? 450'
67
91 13670 1215
1786 216.9 54*
294.6 10929
7L189
38570 61710 *>257 -- 510
1750 4000
.100
no
16400 1457
2143 260.3 60*
361.0 13114
7090
45000 72000 10800 11090
39370 62990
9450
127 19120 1700
2500 303.6
66
415.0 15300
7091
51430 82290 12340 12670
45000 72000 10800
146 21900
1943
2857 346.9 71*
477.6 17485
7092
57850 92560 13880 14260
50620 80990 12150
164 24600 2186
3214 390.3 77*
572.3 19671
4*
7093
64280 102850
15430 15840
89980 13500
182 27300
2429
3571 433.6 83*
662.1 21855
Dimensions and Data -- Inches
Boiler Number
7U78 7LI79
Shell Oiemeter--Inside
42 42
A --Boiler Width Overall B --Boiler Length C --Boiler Height O --Boiler Length Overall t --Water Line Height
44 10 87 104
73*
44
88* 17 112*
73*
F --Water Column Height G --Steam Supply Height H --Smoke Outlet Height J --Coil Connection Height
71* 92 72 76*
71* 92 72 76*
K --Steam Supply 1L --Safety Valve
16 18 12 12
M --Firebox Length N --Firebox Width P --Firebox Height
U36P* 32
82 36* 32
Q --Opened Firedoor to Boiler R --Surface Blovroff
20 20 12 12
S --Return Height T --Smoke Outlet Diameter
18 IS 22 22
"U --Steam Supply Size V --Return Size
66 44
W --Smokebox Depth--Front
X--
--Rear
AA-- Bose--Width
BB--
--Length
CC--
--Height
10 14
a
83* 14
10 14
48 92 14
DD--Tube Replacement Space--Front
EE--
--Rear
71 79Vi 67 75*
FFxGG--Firedoor opening in bir. width x height
One 27** x 13**
HH--Centerline blr. to firedoor opening JJ --Height Doors from Bot. of Boiler
1* 8*
KK--Foundation--Width
LL--
--Length
36* 67
36* 75*
Breeching Die. One Boiler Stack Oiemeter
--Height
22 19
Ft 45
22 20
50
Breeching Die. Two Boilers
Stack--Oiemeter --Height
27 25
Ft 55
28 26
60
| **Outside Surface to Cover ( Approx. Weight
Sq. Ft 122 Lbs. 5400
132 5800
*150 Lb. American.Standard Flange "includes Front Head and Smokebox. fOne or more valves furnished depending on required capacity.
7080
48
50 87 91* 113 77
75 96* 75* 80'
18 14
80* 42* 34
22* 12
18 24
8 4
11 IS
54 90* 14
77 73
3* 8
42* 74
24 21 50
30 28 60
145 6700
7081
48
50 100* 91* 126* 77
75 96* 75* 80
11 14
94 *2* 34
22* 12
11 24
8
4
11 15
54 104
14
90* 86*
7082
54
56 92* 103 119* 86*
84* 108
85 90
18 14
86 48* 37*
22* 18
11 28
4
12 IS
60 96 14
n*
78*
7083
54
56 107* 103 134* 86*
84* 108 8$ 90
n
14
101 48* 37*
22* 24
It 21
1 4
12 15
60 111
14
96* 93*
7084
60
62 112 113* 140 97
95 118*
94* 100*
21 14
104* 53* 40*
26* 24
21 30
8
4
12 16
66* 115*
17
101 97
7085
66
68 119* 119 147* 100
98 123* 98 103*
21 14
112 59* 43
26* 24
21 31
8 4
12 16
73 123
17
108* 104*
7086
72
74 114 128* 148 109*
107* 133 106* 113
n
16
106* 65 49
29* 24
21 35
8
4
14 20
79 117*
17
101 95
7087
72
74 129* 128* 163* 109*
107* 131 106* 113
21 16
122 65 49
29* 24
21 35
8
4
14 20
79 133
17
116*
no*
7088
78
80 145*
136 179* 115*
113* 141* 113* 118*
21 16
138 71 54*
29* 24
23 39
10 6*
14 20
84* 149
17
112362#*
7089 7080
84 84
16 134 161* 168 138*
86 155 161* 189 138*
136* 167 136 142
136* 167 136
142
21 24 16 16
126 147 77 77 66 66
29* 24
29* 24
2? 27 41 43
10 10 6* 6
14 14 20 - 20
19317#* 21
91* 159*
21
121 142 115 136
7091
90
94 153* 172 193* 149*
147* 178 145 152*
24 22
144* 82 72
29* 30
27 46
12 6*
16 24
97* 157
21
138* 130*
7082
90
94 170* 178 210* 155
153 183* 150* 158*
24 24
161* 82 77*
29* 30
27
a
12 6*
24
97* 174
21
155* 147*
7093 96
173 189* 213 164* 162* 195
161
27 163 87 83* 29* 30
50
6*
24 103* 176*
21 158 150
Two 16* X 11*
Two 20* x ir
Two 23* x 15*
3* 8
*2* 87*
24 22 60
31 29 70
162 7600
6 1
48* 79*
28 24 55
34 32 65
110 8800
6 t
48* 94*
21 26 65
36 34 75
202
a oooo
4* 1
53* 99
30 28 65
40 37 75
231 11800
7* 1
59* 106#
31 29 70
41 38 80
265 13600
6*
I
65 101
35 31 65
44 41 75
285 15300
6* 1
65 116*
3S 33 75
47 44 85
313 17000
10 10
71 132 Vi
39 36 90
50 47 100
37$ 20100
13 10 77
m
31 80 54
so
90
23200
13 10
77 142
43 40 100
52 110
26100
12 11
82 140*
46 42 100
11 82 157 Vi
44 110
11 87 160
46
no
56 59 110 120
62 120
33400 37300 42000
33
Tubes: Size, Length and Number Kewanee Firebox Boilers --
Portable and Brtcliiet Rivaled and Welded Down-Draft end Up-Draft
Kewanee Firebox Boiler
Riveted
Single-Pass
Up-Draft Brickset or
Portable Type K
Boiler
TUBES No.Dia. Length
0 12-3"x 4' 6 " 1 17-3"x 4' 1 " 2 17-3"x 4' 8 " 3 17-3"x 5' 2 "
4 28-3"x 4' 8 " 5 28-3"x 5' 8 " 6 28-3"x 6' 8 " 8 39-3"x 6' 2 " 9 39-3"X T 2 "
10 46-3"x 6' 8 " 11 46-3"x 7' 8 " 12 46--3"x 8' 8 " 13 39-4"x 9' 1 " 14 39-4"x11' 1 "
15 48-4"x10' 1/a" 16 48-4"x12' V/a" 17 62-4"x10' 7/g" 18 62-4"x12' V/a" 19 82-4f'XlO' V/a" 20 82-4"x11' 7/a"
Net for Boilers Built before 1918.
Kewanee Firebox Boiler
Riveted
Single-Pass
Smokeless Down-Draft
Brickset or Portable Type K
Boiler
TUBES No.Dia. Length
104 28-3"x 4' 8 " 105 28-3"x 5' 8 " 106 28-3"x 6' 8 "
107 39-3"x 5' 2 " 108 39--3"x 6' 2 " 109 39-3''x 7' 2 " 110 46--3"x 6' 8 " 111 46--3"x T 8 " 112 46--3"x 8' 8 "
113 39--4"x 9' 1 " 114 39-4"x11' 1 " 115 48--4"x10' V/a" 116 48-4"x12' V/a"
117 62-4"x10' 7'/8" 118 62--4"x12' V/a" 119 82-4"x10' I'/g" 120 82--4"x11' 7/a"
Not for Boilers Built boforo 1918.
Kewanee Firebox Boiler Riveted Double-Pass Smokeless Down-Draft
DIRECT TUBES RETURN TUBES
Boiler No.Dia. Length
No.Dia. Length
307 308 309
' 310 311 312
313 314 315 316
317 318 319 320
321 322 323 324
29-3"X 2' 9 " 29-3"x 3' 7 " 29-3"x 4' 1 "
28-3"x 7' 6 "
28-3"x 8'10/g" 28_3"x 9'10/g"
38-3"x 3' 1 " 38-3"x 3' 7 " 38-3"x 4' 1 "
36-3"x 9' 4!4" 36-3wx10' 4J4" 36-3"x11' V/a"
28-4"x 4' 7/a" 28--4"x 5' V/a" 28-4"x 5'10/g" 28-4"x 6' 4 "
28-4"x11' 4%" 28-4"x12' 4%" 28-4"x13' 8 " 28-4"x14' 8 "
38-4"x 6' 2'/g" 38-4"x T 8 " 46--4"x 6' 4/g"
46-4"x T 2/a"
34--4"x14' 0 34-4"x16' 0 46--4"x14' 8
46-4"x16' 0
" " "
"
55--4"x T V/a" 55--4''x 7' 7 " 68--4"x 8' 2 " 68--4"x11' 8 "
50-4"x15'11 50--4"x16'11 66--4"x18' 0 66-4"x22' 0
" " " "
Not for BoJIers Built before 1918.
Kewanee Firebox Boiler Riveted Double-Pass
Up-Draft
DIRECT TUBES RETURN TUBES
Boiler No.Dia. Length
No.Dia. Length
407 29--3"x 3' 7 " 28-3"x T 0/a" 408 29--3''x 4' 0 " 28-3"x 7'11 " 409 29-3"x 5' 1 " 28_3"x 9' 6/,"
410 38-3"x 4' 6 " 36-3"x 8' 5/a" 411 38--3"x 5' 1 " 36--3"x 9' 6/a" 412 38-3"x 5' 7 " Se-S'^IO* 6/a"
413 28-4"x 5'11 /a" 28-4"x10'10%" 414 28--4"x 6' 7/a" 28--4"x12' 0%" 415 28--4*'x T 9/a" 28-4"x12' 9 " 416 28--4"x 9' 1/a" 28-4"x14' 7 "
417 38-4"x 8' 6 " 34--4"x14' 0 " 418 38--t"x 9' 7 " 34--4"x15' 7 " 419 46--4"x 8' 0/g" 46--4"x14' 0 " 420 46--4"x 9' V/a" 46--4"x15' 7 "
421 55-4"x 9' 6/a" 50-4"x16* 0 " 422 55--4"x11' 0/a" 50-4"x18' 0 " 423 68-4"x11' 0 " 66-4"x18' 0 " 424 68-4"x1V 6 " 66-4"x20' 0 "
Not for Boilers Built before 1918.
Kewanee Firebox Boiler Riveted Double-Pass "500" Series Up-Draft
DIRECT TUBES RETURN TUBES Boiler No.Dia. Length No.Dia. Length
524 38-3"x 6' 6Ya" se^'x^ o "
526 28-4"x 5' 5/g" 52-3"x10'10%"
528
28-4"x 6' 1/B" S2-3"x12' 0%"
530 34--4"x T 3/a" 52-3"x12' 9 "
532 34-4"x 8' V/a" 52-J"x14' 7 "
534 43-4"x T 6/a" 66-3"x14' 0 " 536 43-4"x 8' 7/a" 66-3"x15' 7 " 538 49-4"x T 0/a" 82-3"x14' 0 " 540 49-4"x 8' V/a" 82-3"x15' 7 "
542 55--4"x 8' 6/a" 10O-3"x15' 6 " 544 55--4"x 9'11/a" 100-3''x17' 5 "
Kewanee Firebox Be Riveted Double-Pass "800" Series Up-Draft
DIRECT TUBES RETURN TUBES Boiler No.Dia. Length No.Dia. Length
832 46-3"x 3'10%" 46-3"x 9'10 " 833 46-3"X 4' 4%" 46-3"x10'10 " 834 58_3"x 3' 9%" 58-3"x 9' 2%"
835 56-3"x 4' 6/a" 58-3"x10' 5%"
836 66-3"x 5' 0 " 66-3"x11' 0 "
837 66-3"x 5' 9 "
3"
838 85--3"x 4' 9 " 83-3"xl1' 3 "
839 85-3"x 5' 6 " 83-3"x12' 6 "
840 104-3"x 5' 0 " 103-3"x12' 0 "
841 104-3"x 6' 3 " 103-3"x13' 9 " 842 121-3"x T 3 " 12D-3"x14' 9 " 843 121-3"x 8' 8 " 120-3"x16' 8 "
"900" Series Down-Draft
DIRECT TUBES RETURN TUBES Boiler No.Dia. Length No.Dia. Length
932 46-3"x 3' 3%" 46^3"x10' 1 " 933 46--3"x 3' 8J4" 46-3"x10'11/I" 934 58-3"x 2'10%" 58-3"x10' 1H" 935 58-3"x 3' 1%" sa-s'^io-io^"
936 66-3"x 3' 7'/g" 6"x11' 4%" 937 66-3"x 4'10/g" 66-3"x13' 1/a"
938 85-3"x 3'10 " ss^'x^ 2 " 939 85-3"x 4' 2/a" 83-3"x13' 0 "
940 104-3"x 3' 7 " lOS^'x^ 4/a"
941 104-3"x 3' 8/a" 103-3"x13' 0 "
942 121-3"x 4'10/g" 120-3"x14' 8 "
943 121-3"x T 5
120-3"x17' 9?4"
KIQTC.
WHEN ORDERING TUBES GIVE DATE OF BOILER OR SERIES NUMBER, AND CHECK ACTUAL LENGTHS AND NUMBER IN EACH TUBE NEST.
LENGTHS IN THESE TABLES INCLUDE 1 IN. FOR ROLLING AND BEADING. Kewanee Boiler Corp. assumes no responsibility for tubes ordered too long or too short.
Ktwan Firebox Boilers
Kewanee Firebox Boiler Weld + Rivet Double-Pass
"5000" Series Up-Draft
BOILER Coal - Oil
DIRECT TUBES RETURN TUBES No.Dia. Length No.Dia. Length
5029-5129 5033-5133 5034-5134 5036-5136
5038-5138 5039-5139
5040-5140 5041-5141
5042-5142 5043-5143
5044-5144 5045-5145
30-3"x 4' 3%" 49-3"x 3' 7J4" 49--3"x 4' 7!/," 49-3"x 5' 734"
30-3"x 9' 8 " 48-3"x 8' 7/a" 48-3"x10- 0%" 48-3"x11' 7 "
60-3"x 4'1134" 66-3"x10'11J/i" 60-3"x 6' 1!4" 66-3"x12- 7 "
82-3"x 6' 1/2" 76-3"x12- 734" 82-3"x V 434" 76-3"x14' 4%"
101-3"x 6'10%" 98-3"x13'1034" 101-3"x 8' V/t" 98-3"x15' 734"
122-3"x 8' 7/2" 108-3"x16' 1*4" 122-3"x10- t%" 108-3"x18' 1!4"
Kewanee Residence Boiler Welded Two-Pass Tubes
Round Type "R"
BOILER Coal - Oil
DIRECT TUBES RETURN TUBES No. Dia. Length No.Dia. Length
735-2735 1735 736-2736 1736
4-4"x 17 " 5-4"x 19!/2"
4-4"x 27 " 5-4"x 29 "
Square Type "R"
740-2740 741-2741 742-2742 743-2743
1740 1741 1742 1743
745-2745 746-2746 747-2747 748-2748
1745 1746 1747 1748
7-4"x 1' 634" 7-4"x 2' 034" 7--4"x 2' 634" 7-4 x 3' 034"
10-4"x 3' 034" 10-4"x 3' 634" 10-4"x 4' 034" 10-4"x 4' 634"
7-4"x 2' 4%" 7-4"x 2'1034" 7-4"x 3' 434" 7-4"x 3'1034"
10-4"x 3'1034" 10-4"x 4' 434" 10-4"x 4'1034" 10-4"x 5' 434"
"6000" Series Down-Draft
6027-6127 6028-6128 6029-6129 6030-6130 6031-6131 6032-6132
6033-6133 6034-6134 6036-6135 6036-6136
6037-6137 6036-6138 6039-6139
6040-6140 6041-6141
6042-6142 6043-6143
6044-6144 6045-6145
30-3''x 2' 234" 30-3"x 2' 914" 30-3"x 3' 234" 40-3"x 2' 734" 40-3"x 3' 234" 40-3"x 3' 734"
49-3"x 2-1034" 49_3"x 3/ 4y2" 49_3"x 3' 914" 49--3"x 4' 5 "
60-3"x 3' 2 " 60-3"x 3'10/2" 60-3"x 5' 434"
82-3"x 4-1134" 82-3"x 6' 3/g"
101-3"x 6' 134" 101-3-x 8' I/."
122-3-x 8' 534" 122-3"x10- 2/s"
30-3"x 7' 9/2" 30-3"x 634" 30-3"x 5/s" 36-3"r 8 " 36-3"x 9' 3 " 36-3"x 9-11 "
48-3"x 8'11 " 48-3"x 9' 734" 48-3-xlO- 6/2" 48--3"x11' 234"
66-3"x 9'1134" 66-3"x11' 034" 66-3"x12'11/2"
76-3-X12' 934" 76-3"x14' 334"
98-3"x14' 5/2" 98-3"x16'11 "
108--3"x17' 334" 108-3"x19' 6 "
Kewanee Firebox Boiler
Welded
Single-Pass
"G" Series Up-Draft
Boiler
TUBES No.Dia. Length
Kewanee Type "C" Boiler Welded Two-Pass Tubes Smokeless and Direct Draft
BOILER Coal - Oil
DIRECT TUBES RETURN TUBES No.Dia. Length No.Dia. Length
749-2749
750-2750 751-2751 752-2752
753-2753 754-2754 755-2755
1749
1750 1751 1752 1753 1754 1755
756-2756 1756 757-2757 1757 758-2758 1758
759-2759 760-2760 761-2761 762-2762
1759 1760 1761 1762
763-2763 764-2764 765-2765 766-2766
1763 1764 1765 1766
767-2767 768-2768 769-2769 770-2770
1767 1768 1769 1770
21-3"x 2' 534" 21-3"x 2'11/2" 21--3"x 3'11/2" 21-3"x 4' 734" 27-3"x 4' 234" 27-3"x 4-1034" 27-3"x 5' 934"
35-3"x 5' 6/4" 35-3"x 6- 1/2" 35-3"x 6' 8/2"
48-3"x 5' 7/4" 48-3"x S' 834" 62-3"x 6' 134" 62-3"x 7' 034"
70-3"x 7' 6/4" 70-3"x 8' 9/*" 82-3"x 7' 934" 82-3"x 8-1034"
94--3"x 8' 7/4" 94-3"x 9-1134" 124-3"x 8' 8 " 124-3-xlO- 2 "
24-3"x 4- 234" 24-3-x 4' 834" 24-3"x 5' 834" 24-3"x 6' 5 " 30-3"x 5'11/2" 30_3"x 6' 7/2" 30-3"x 7, 7
34-3"x 7' 3/2" 34-3"x 7-1034" 34-3"x 8- 634"
48-3"x 7' 6/2" 48-3"x 8' 8 " 56-3"x 8' 1/2" 56-3"x 9/ 0 "
62-3"x 9' 8 " 62-3"x10-11 " 86-3-x 9'11/2" 86-3"x11' 0 "
92-3"x10-11 " 92-3"x12- 3/2" 118-3"x11- 0 " 118-3"x12- 6 "
G-23 G-28 G-32 G-36
G-39 G-44 G-51
G-55 G-64 G-71
36-3"x 3' 934" 36-3"x 4' 834" 36-3"x 5' 834" 36-3"x 6' 7/,"
52-3"x 5' 034" 52-3"x 5-10/g" 52-3"x 6'10*4"
66-3"x 5-1134" 66-3"x 7' 034" 66-3"x 7-1134"
EXCEPTIONS FOR EARLIER STYLES
Boilers Previous to Date: Series
BOILER Coal - Oil
DIRECT TUBES RETURN TUBES No.Dia. Length No.Dia. Length
12- 6-29 1-X 1-21-31 1-X
12-22-32 1-X 12-22-32 1-X 12-22-32 1-X
750-2750 1750 759-2759 1759
756-2756 1756 757-2757 1757 758-2758 1758
21-3"X 3' /2" 48-3"x 8' 2/*"
40-3"x 4' 434" 40-3"x 4-1034" 40-3"x 5' 434"
24-3-x 4' 934" 48-3"x 8' 1/2"
44_3"X 6' 2 " 44-3"x 6' 8 " 44-3"x 7' 2 "
klQTC,
WHEN ORDERING TUBES GIVE DATE OF BOILER OR SERIES NUMBER, AND CHECK ACTUAL LENGTHS AND NUMBER IN EACH TUBE NEST.
LENGTHS IN THESE TABLES INCLUDE 1 IN. FOR ROLLING AND BEADING EXCEPT ON RO.R--SQ.R TUBE LENGTHS INCLUDE ONLY %" TO 1".
Kewanee Boiler Corp. assume* no responsibility for tubes ordered too Ions or too short.
iV LAiA bUUA * 'iAfl t JC..Q. 21 SP 4-50 REPLACES 11-47
Tubes: Size, Length and Number KfeWANEfc Firebox Boilers (Simplified Practice)
15 Lb., also Hi Pressure.
Kewanee Firebox Boiler Riveted Double-Pass "500" Series Up-Draft
Boiler
DIRECT TUBES RETURN TUBES
No.Dla. Length
No.Dla. Length
576 577 578 579
580 581 582 583
584 585 586
587 588 589 590
24-3"x3' 2%" 24-3"x4' 2H" 32--3"x3' 3H" 32-3"x4' O'/s"
42_3"x3' 6Vi" 42-3"x4' 3H" 53-3"x3' 4 " 53-3"x4' 2 "
68-3"x4' 3 " 68-3"x5'10 " 82-3"x5' 8 "
101-3"x5' 2'/," 101-3"x7' OH" 117-3"x7' OVi" 117-3"x8' 9 Vi"
23-3"x V 8 " 23-3"x V 7 Vi" 30-3"x T 9 " 30-3"x V 5 Vi"
39-3"x 7'11 Vi" 39-3"x V 3 " 50-3"x V 8 " 50-3"x11' 4 "
62-3"x11' 5 " 62-3"x13' 4 " 74-3"x13' 2 "
87-3"x13' 0 " 87-3"x15'10Vi" 108-3"x15'10Vi" 108-3"x18' IVi"
Kewanee Firebox Boiler Riveted Double-Pass "400" Series Up-Draft
480 24--4"x 5' 8Vi" 20--4"x10' 2 " 481 24--4"x 6'11'/," 20-4"x11'10Vi" 482 28-4"x 5' 7Vi" 28-4"x11'11 Vi" 483 28-4"x 6'10Vi" 28-4"x14' 0/t"
484 38-4"x 6'11 Vi" 34--4"x14' IVi" 485 38-4"x 9' 1 Vi" 34--4"x16' 7 Vi" 486 46--4"x 7'11 " 46-4"x15' 5 "
487 55-4"x 8' OH" 50--4"x 15'10 Vi" 488 55--4"x10" 8H" 50-4"x19' 6 " 489 68--4"x 9'10 " 66--4"x18' 8 " 490 es-^'x^ OH" 66-4"x21' 5 "
Kewanee Firebox Boiler Riveted Double-Pass '300" Series Smokeless Down-Draft
376 377 378 379
380 Hl.Pr.
380 381 382 383
384 385 386
387 388 389 390
24--3"x 1'IOH" 24--3"X 2' 8%" 32-3"x 2* 1'/," 32_3"X 2- 8H"
42-3'x 2' 4H'
24--4"x 4' 4 Vi" 24--4"x 5' 4H" 28-4"x 4'11 Vi" 28-4"x 6' 2 "
38--4"x 6' 4 " 38--4"x 8' 5 " 46-4"x 7' 4 "
55--4"x 7' 5H" 55--4"x10' OH" 68-4"x 9' 2 " 68--4"x11' 5 "
23-3"x T 4 " 23--3"x 8' 4 " 30-3"x T 6Vi" 30-3"x 8' 4 "
39-3"x 7'11H'
20-4"x 9'11 Vi" 20--4"x11' 8 " 28-4"x11' 3 Vi" 28--4"x13' 4 "
34--4"x13' 6 " 34-4"x15'11 " 46-4"x14'10 "
50-4"x15' 3 Vi" 50-4"x18'10Vi" 66-4"x18' 0 " 66--4"x20' 9 "
Kewanee Firebox Boiler
Riveted
Single-Pass
Brickset & Type K Up-Draft
Boiler
TUBES No.Dla. Length
3- 3 K 4- 4 K 5- 5 K 6- 6 K
17-3"x 5' 2 28-3"x 4' 8 28-3"x 5' 8 28-3"x 6' 8
" " " "
8- 8 K 9- 9 K
10-10 K 11-11 K 12-12 K 13-13 K 14-14 K
39-3"x 6' 2 39-3"x T 2 46-3"x 6' 8 46-3"x T 8 46-3"x 8' 8 39--4"x 9' 1 39-4"x11' 1
" " " " "
"
"
15-15 K -16 K
17-
18- 3 K
1920 !0 K
48-4"x10' I'/s"
4a-4'^2' I'/g"
62-4"x10' 7Vi" 62-4"x12' I'/s" 82-4"x10' I'/s" 82-4"x 11' 7'/,"
Kewanee Firebox Boiler
Welded
Single-Pass
"G" Series Down-Draft
Boiler
TUBES No.Dla. Length
G-18 G--22 G-26
G-30 G-35 G--40 G--45
G-50 G--60
36-3"x 2' 5H" 36-3"x 3' 5H" 36-3"x 4' 3H"
36-3"x 5' 3%" 36-3"x 6' 4/," 52-3"x 5' OH" 52-3"x 5'10'/g"
52-3"X 6' 7%" 52-3"x 8' 2H"
Kewanee Firebox Boiler
Welded
Single-Pass
"P" Series Up-Draft
P-18 P-22 P-26
P-30 P-35 P-40 P-45
P-50 P-60
36-3"x 3' 3 36-3"x 4' 2 36-3"x 5' 0
36-3"x 6' 0 36-3"x 7'. 1 52-3"x 5' 8 52-3"x 6' 6
52-3"x 7' 3 52_3"x 8'10
Kewanee Boiler Scotch Marine Type Welded "M-8000" Series
Boiler
TUBES No.Dla. Length
M8173 M8174
M8175 M8176 M8177
23-3"x 6' 6%"
23-3"x T 8H" 37-3"x 6' 0 "
37-3"x 6'11H" 37-3''x 8' 0/t"
M8178 M8179 M8180 M8181
53-3"x 6' 6Vi" 53-3"x 7' 3 Vi" 71-3"x 6' 8V4" 71-3"x T 9%"
M8182
M8183 M8184 M8185
89--3"x T 8Vi"
89-3"x 9' OH" 109-3"x 9' 4 " 109-3"x11' 3 "
M8186 M8187
128-3"x11' 2H" 128-3"x12'10 "
M8188 MSI 89 M8190
148-3"x14' 0 " 178--3"x14' 0 " 200-3"x13' 4%"
Kewanee High Pressure
Portable
Riveted
"Scottie Junior" Series
Boiler
TUBES No. Dia. Length
HM 9 HM 15 HM 20 HM 25 HM 30
28-3"x 3' 6 28-3"x 5' 3 28-3''x 7' 0 36-3"x 6'11 36-3"x 8' 4
" " " " "
KJ/-yrr. INV-/IC.
WHEN ORDERING TUBES GIVE DATE OF BOILER OR SERIES NUMBER, AND
CHECK ACTUAL LENGTHS ALSO NUMBER IN EACH TUBE NEST.
LENGTHS IN THESE TABLES INCLUDE 1 IN. FOR ROLLING AND BEADING.
Kewanee Boiler Corp. assumes no responsibility for tubes ordered too long or too abort.
Ill
Tubes: Size, Length and Number Kewanee Firebox Boilers (Simplified Practice)
Kewanee Residence Boiler Welded Two-Pass Tubes
Round Type "R"
BOILER lime for Z734-273C ssms for 0734-0736
DIRECT TUBES No.Dla. Length
RETURN TUBBS No.Dla. Length
-1733 734-1734,1 X
735-1735,4A5X 6X
736-1736,4A$X 6X
___ 1737,1 X
4-3 "x1354" 4-3J4"x1'254" 4-4 "xl'5 "
4-4 "xl'5 "
5-4 "x17 " 5-4 "x17 " 5-4 "xZ9/i''
4-3 "x16J4 " 4-3/a"x2* 0 " 4-4 3 " 4-4 "xZ 4/,"
5-4 "xZ 4%" 5-4 "xZ 654"
5-4 "x3' 9>/t"
Square Type "R"
ume for 2740-274< ame for 0740-0740
740-1740 741-1741 742-1742 743-1743
745-1745 746-1746 747-1747 748-1748
7-4 "xV6%" 7-4 "x2'054" 7-4 "x2'6%" 7-4 "x3'054"
10-4 10-4 10-4 10-4
"x3 0|4" "x3'6%" "x4'05i" "x4'6 54"
7-4 "x2* 4%" 7-4 "x2'1054" 7-4 "x3' 4%" 7-4 "x3'l054"
10-4 10-4 10-4 10-4
"X3T054" "x4' 454" "x4'1054" "x5' 454"
Square 83 "R"
83 R1 83R2 83R3 83 R4
83 R 6 83 R7 83 R8 83 R9
16-2!4"x1'654" 16-2|/2"x2'0%" 16-254"x2'654" 16-2J4"x3'0 54"
21-2!4"x3'054" 21-2!4"x3'654" 21-2!4"x4'054" 21-254"x4'654"
15-254"x2' 454" 15-2/2"x2'10%" 15-2J4"x3' 454" 15-254"x3'1054"
20-2 J4"x3'1054" 20-2'/2"x4' 454" 20-2!4"x4'1054" 20-2'/2"x5' 4%"
Kewanee Type "C" Boiler Welded Two-Pass Tubes Smokeless and Direct Draft
BOILER
me for 2773*2790 me for 0773*0790 *am for 27L73-27L90
DIRECT TUBES No. Din. Length
RETURN TUBES No.Dla. Length
1773-7L73 774-1774-7 L74 775-1775-7L75 776-177 6-7L76
777-1777-7L77 778-1778-7 L78 779-1779-7L79
780-1780-7L80 781-1781-7L81 782-1782-7L82 783-1783-7 L83
784--1784--7L84 785-1785-7L85
5-1786--7L86 7-1787-7 L87
788-1788-7 L88 789-1789-7 L89 790-1790-7 L90
21-3"x 2' 554" 21-3"x 2-1154" 21-3"x 3' 554" 21-3"x 4' 4 J4"
27-3"x 4' 254" 27-3"x 4'1054" 27-3"x 5' 554"
35-3"x 5' 654" 35-3"x 6' 854" 48--3"x 5' 9J4" 48--3"x 7' 1 "
62-3"x 7' 3 54" 70-3"x 7'10J4" 82--3"x T 2%" 82--3"x 8' 5>4"
94-3"x 9' 854" 124--3"x 9' 154" 124--3"x 10*1054"
24-3"x 4' 2^4" 24-3"x 4' 854" 24-3"x 5' 2%" 24-3"x 6' 154"
30-3"x 5'11 54" 30-3"x 6' 7 J4" 30-3"x 7' 3 "
34-3"x 7' 314" 34-3"x 8' 554" 48-3"x 7' 9 " 48-3"x 9' 054"
5S-3"x 9' 354" 62-3"x10' 054" 86--3"x 9' 4J/2" 86-3"x10' 7 J4"
92-3"x12' 054" 118-3''x11' 5 54" 118-3"x13' 254"
Kewanee Firebox Boiler Weld -j- Rivet Double-Pass
"5000" Series Up-Draft
BOILER Coni - Oil
DIRECT TUBES No.Dla. Length
RETURN TUBBS No.Dla. Length
5076-5176 5077-5177 5078-5178 5079-5179
30-3"x1'11 30-3"x2' 8
30-3"x3' 1 30-3"x3' 6
"
"
" "
5080-5180 5081-5181, IX
2X4 Up
40-3"x3' 8%" 49-3"x3' 154"
40-3"x4' 7 "
5082-5182 5083-5183
49-3''x3.' 854" 49-3"x4' 654"
5084-5184 5085-5185
60-3"x4' 954" 60-3"x6' 6 54"
5086-5186 5087-5187
78-3"x5' 654" 78-3"x6' 954"
5088-5188
97-3"x6' 354"
5089-5139 5090-5190
116-3"x7' 054" 116-3''x8' 954"
30-3"x V 4 30-3"x 7' 1 30_3"X 8' 0
30_3"X 8'11
" " "
"
36-3"x 8' 8 " 48-3"x 8' 1 " 36-3"x10' 0 54"
48-3"x10' 0 " 48-3"x11' 8 "
60-3"x11'11J4" 60-3"x 14' 0 "
78-3"x13' 0/2" 78-3"x14' 7J4"
98-3"x15' 1 14"
106-3''x15'10|4" 108-3"x18' V/2"
"6000" Series Down-Draft
6077-6177 6078-6178 6079-6179
6080-6180 6081-6181 6082-6182 6083-6183
6084-6184 $085-6185 6086-6186 6087-6187
6088-6188 6089-6189 6090-6190
30-3"x1' 954" 30-3"x2' 354" 30-3,'x2' 9J4"
4O-3"x2'1054" 40-3"x3' 754" 49-3"x3' 4J4" 49-3"x4' 2J4"
60-3"x4' 454" 60--3"x6' 054" 78-3"x5' 154" 78-3''x6' 454"
97-3"x5'1154" 116-3"x6' 8/*" 116-3"x8' 554"
30-3"x 7' 254" 30-3"x T 854" 30-3"x 8' 7 "
36-3"x 8' 6 " 36-3"x 9'11 " 48-3"x 9' 754" 48-3"x1 V 3J4"
60-3"x11' 814" 60-3"x13' 654" 78-3"x12' 7J4" 78-3"x14' 254"
98-3"x14' 954" 108-3"x15' 6 " 108-3"x17' 9 "
MQTC. w
WHEN ORDERING TUBES GIVE DATE OF BOILER OR SERIES NUMBER, AND
CHECK ACTUAL LENGTHS NUMBER IN EACH TUBE NEST.
ALSO
LENGTHS IN THESE TABLES INCLUDE 1 IN. FOR ROLLING AND BEADING. . . . EXCEPT ON RO.R--SQ.R--S3R BOILERS LENGTHS INCLUDE %--V\
Eevtnu Boiler Corp. uiunwa bo responsibility for tubes ordered too lone or too short
BOILER STAMPINGS
Each Kewanee Low Pressure Boiler has identifying marks stamped in the shell plate. These stampings should be uncovered and visible.
00000 lb (weight in pounds)
00000 (stock order number)
LM-000 (boiler size number) (Q) KEWANEE (ASME clover leaf symbol)
MAX. WP STEAM 15 lb WATER 30 lb
(maximum working pressure)
VC 0000 lb (valve capacity)
1 00000 (Insurance Company mark &
` number)
1954 (year in which boiler was built)
AMERICAN STANDARD HEAT TRANSFER PRODUCTS DEPARTMENT
SALES OFFICES IN ALL PRINCIPAL CITIES
Executive Offices: Detroit, Michigan 48232 In Canada: 1401 Dupont St., Toronto 172, Ontario International Export Division: 40 West 40th St., New York, N. Y. 10018
FORM 3149 IM 7-69 JM
LITHO IN U.S.A.