Document GmQgk5vbdYMyvbagK30vQG4Mr

COMPANY CONFIDENTIAL ' OTHER LOCATIONS W. R. Richards M. E. Gibbs J. W. Molloy - WGK W. R. Kellogg - Nitro D. C. Armstrong - WGK D. W. Jackson - WGK T. E. Greenman - WGK GENERAL/OFFICES % q> "S ,, D. Danna/(4) W. A.\Kuhn Hosmer H./S. Bergen y. M. Kountz /R. J. Stratmeyer / N. L. Sample ANNISTON W. B. Papageorge J. C. Landwehr C. K. Eastman H. L. Williams G. W. Miller R. A. Haydel J. T. Bell JOB NO. 570:455 PROG. TECHNIC REPORT DEPARTMENT MA PLANT ^ date 5/1/69 TITLE: OBJECTIVE: Liquid Aroclor Catalyst Test To report the results of a plant test on creased catalyst concentration during chlorination. PERSONNEL: REPORTED BY: SUMMARY: E. E. Bowles (V. R. Haupt) E. E. Bowles A test of catalyst concentration effects on Liquid Aroclor Thermal Chlorides was conducted by the Anniston plant. The test covered 54 days of continuous chlorinator operation. The test did not show any overall improvement in Thermal Chlorides as a result of the increase in catalyst concentration to 0.05%. Normal plant catalyst concentration was 0.015%. E. E. Bowles Technical Services Department jw ANNISTON DSW 199993 STLCOPCB4058057 Anniston TSD Progress Report 370:455 (2) . 2. Background: During the 1968 Functional Fluids Business Group Meeting in Anniston, Dallas Armstrong presented the following graph correlating Thermal Chlorides to catalyst concentration. .60 .50 (0 0o) .40 fuo-l .30 O CO .20 B 0) Jh2I.10 .05 .10 .15 .20 7. Catalyst Figure 1 Based on this information the Anniston Plant Aroclor Department engaged in a plant test. Details: The catalyst concentration was increased to 0.057. on June 20, 1968 and the continuous 1242 chlorinator ran with this concentration until July 24, 1968. Premeasured bags of catalyst were used during the test to assure the accuracy of the concentration. A careful check was kept over the catalyst addition to assure uniformity through out the test. The TCC data collected was compared statistically with the TCC data for the month before the test. A plot of this data is shown in Figure 2. Conclusions: The TCC averages for the month before the start of the test was 0.205. The average during the test was 0.202. This is an insignificant improvement com pared to the 0.102 TCC indicated by the laboratory tests. A note should be made, however of the decrease in variability of the TCC during the test. DSW 199994 STLCOPCB4058058 Augus June J u ly Anniston TSD Progress Report 370:455 (2) STLCOPCB4058059 May Anniston TSD Progress Report 370:455 (2) 4. Future: There are no plans for further plant catalyst concentration tests, however, variations in other chlorination variables, such as temperature, are under consideration. E. E. Bowles jw DSW 199996 STLCOPCB4058060