Document Gm7pxvGGEM66aq3Mb7yOK1wQn
II 1 I
I ^ WW I IMkaJl" ^ I M .
PLAINTIFF'S EXHIBIT
MBL-203
oats November 13, 1975
C. R. Eastman D. S. Miller V. 0. Mitteriehner R. <7. Potts, M.D. L. Ryall J. K. Stewart, M.D. Z. Averill
- New York - New York
- Beaumont - Dallas - Beaumont
- 3eaumont - Edison
INDUSTRIAL HYGIENE SURVEY
EH #92-75 Mobil Chemical Company Petrochemical Division Ethylene-Aromatics Plant 3e aumont, Texas 13 to 29 October 1975
Attached please find the report of the Industrial Hygiene Survey of the Beaumont Ethylene-Aromatics Plant performed by Russel L. Witzke, Indus trial Hygienist, during the period of October 13-29, 1975*
Specific recommendations are contained in the report covering noise control and audiometric testing of noise-exposed employees, improvements in house keeping, environmental sanitation and safe work practices or procedures, e.g., corrosive materials, asbestos, and protection against ultraviolet radiation from the welding operations.
After you have had an opportunity to review this report, please feel free to contact Mr. Witzke at the Beaumont Refinery (Ext. 712) for any addi tional information or assistance you may require to implement these recom mendations.
LL:bh Attachment
Lester Levin Chief Industrial Hygienist
002236 183902
~>,rrran*'`.7''.,'rr^* 'V*
An industrial hygiene survey was performed by Russel L. Nitzke, Industrial Hygienist, between the 13th and 29th of October 1975 at the Xobil Chemical Company, Ethylene-Aromatic Plant, Beaumont, Texas. The primary purpose of this survey was to evaluate employee exposure to noise, benzene, toluene.
environmental sanitation, and housekeeping conditions.
II. SUMMARY
1. Noise
A. Findings
1. Based on personal noise monitoring, employees assigned to the Ethylene Unit were found exposed in excess of their permissible limits (OSHA Regulation 1910.95d).
2. Noise levels are 90 dBA and above in all process areas of the Ethylene Unit, which is an increase above the December 3, 1973 noise level survey made before the plant was expanded.
3. Noise levels inside some operator's sheds and the compressor control room, although below the OSHA limits, are judged high for an efficient and comfor table work environment.
3. Recommendations
1. Signs should be posted at ail entrance ways, or no further than 75 feet apart, encircling noisy areas stating, "Caution - Hearing Protection Required
in This Area".
2. Noise levels inside certain area operator sheds and the compressor control room should be reduced to below 80 dBA, which is considered safe from an exposure duration standpoint.
3. Personnel working inside posted areas must be required by their supervisors to wear hearing protection throughout their work duration and enforcement is emphasized.
U. Employees should have annual audiometric examinations scheduled by
Employee Relations/Medical sis required by Mobil Hearing Conservation Policy
and OSHA Regulations.
<
5. Specific noise reductions through acoustical engineering treatment of equipment is found in Section III 2.3.
002237 183903
2
2. Aroma~ic Valors
A. Findings
The benzene unit operator, railcar, and barge loading personnel are exposed zo concentrations veil belov the action level, vhich is one-half of the respective TLV limit for benzene and toluene.
3. Recommendations
1. Our industrial hygiene survey of August 1974 (VR-59~7!i), recommended improved drainage and collection in the benzene truck loading area. This should also be provided at the rerun tover bottom truck loading station. Spilled materials should be cleaned up immediately after they occur.
2. An NIOSH approved organic vapor respirator should be kept in a sealed cabinet at all loading facilities. When the seal is broken, a replacement should be made and the old unit discarded.
3* Znvironaental Sanitation
A. Findings
Ail toilet and shower facilities were found in generally good repair and kept in a clean sanitary condition. There is a lack of toilet and handwashing facilities in the maintenance and lunch room area (OSHA Regulation 1910.141 C and D).
3, Recommendations
A toilet room with two water closets and four handwashing lavatories with hot and cold water would be adequate in the maintenance area, if used by both Mobil end Rosendahi employees.
4, Housekeeping;
A. Findings
General housekeeping within the unit battery limits was found good. The instrument and fabrication shops are kept in a disorganized and filty condition.
3. Recommendations
Attention should he given to reorganizing stocked materials and cleaning neglected areas. The maintenance area, instrument shop, and warehouse also require specific attention.
5, Hazardous Process Chemicals
A. Findings
Information on the safe handling of locally purchased yard chemicals is not
002238 183904
available. Some of the employee work stations were not constructed with
^ *nai ng
cm.iicul v vO nand^e po-C6Hi.^fl*i i y u&Zcii'dous
storage areas and some chemical mixing tanks were not properly identified.
3. Recommendations
1. Material Safety Data sheets must be obtained on all hazardous materials from the suppliers, preferably by the Purchasing Department or Safety Advisors.
2. Wooden decking at mixing tanks should be replaced with metal decking and stairs.
3. Mixing and injection tanks should be identified for hazardous material contents, ie., "Caution - Corrosive Material", etc.
6. Asbestos
h * xncLxn^s
No asbestos-bearing insulation is being used. Even though new insulation is asbestos free, removal of old materials requires written handling pro cedures and use of respirators as indicated in Mobil Policy, Guide 03-1308.
3. Recommendations
A written asbestos removal procedure must be provided and employees trained in its provisions. An example of minimum requirements is shown in Appendix
7. Ultra-Violet Radiation
A. Findings
Workers have adequate eye protection, but workers in adjacent areas are not protected from ultra-violet radiation produced by welding in the fabrication shops of Mobil or Rosendahl.
3. Recommendations
Portable curtains would reduce adjacent area worker exposure from ultra violet radiation produced during welding operations.
III. INDUSTRIAL HYGIENE SURVEY
1. Noise Exposure
Noise Dosimeters - Daily sound exposure was calculated and registered by a calibrated General Radio Personnel Noise Dosimeter, Type 19^. A registering monitor is fastened to the shirt pocket and a microphone is clipped to the worker's ear or the closest approximation to his ear. The d3A weighted network sound levels are read on a General Radio 19^ Readout Unit,- as the percentage of the allowable OSHA exposure.
002239 183905
The monitor has a lov cut off point of 39-5 c3A which prevents error due to sound levels "below 90 d3A. Sound levels exceeding the maximum 115 aBA permissible noise exposure level limit are also registered. All readings in Table I are corrected for an 3-hour work shift.
3. Results and Discussion
Employees working in the Ethylene unit were exposed to between 50 and greater than 1,000* of their permissible time weighted exposure limits. Consequently, none of the Ethylene unit operators are exempt form audiometric testing, based on normal, day-shift sampling. Operators working in areas rfl, it3, .VU, & #6 were subjected to noise levels where over exposures occurred as presented by data summarized in Table I.
About o0% of the workers sampled used hearing protection, this represents a marked improvement, but still relatively no discipline by enforcement has taken place.
Maintenance and instrument personnel are exposed to different noise levels because of their job assignments, which change frequently. Significantly, personal evaluations of noise exposure cannot effectively be made by the worker. This is evident from the data gathered. Maintenance personnel working inside the Ethylene and 3enzene units must be encouraged to use hearing protection.
2. Ambient Noise Levels
A. Method
Noise Level - Measurements in decibels (dB) were obtained by using a cali brated General Radio Sound Level Meter, Type 1565-3 using the A and C weighting network with the slow meter response. The A network simulates the speech frequencies and is the scale on which the- 0SEA standard is based. The C network gives a more equal weighing to all frequencies, thus giving a flatter response to the overall noise frequencies.
3. Results and Discussion
Noise levels in the Ethylene Unit have increased after the plant expansion from an average of 9^ dBA to 97 d3A. Figures 1 to 5 show noise levels by location on a unit plot plan.
Our industrial hygiene report of December 1973 recommended certain engineering controls which, unfortunately have not been implemented. We reiterate the following acoustical treatment meaisures.
Area #1 and#6
An acoustical engineering consultant of the burner manufacturer should be contacted to design an effective noise reduction program. Mufflers can be installed on electric motor air intake cooling fans to reduce high noise levels by unit pumps. Vented steam should be muffled especially where deaerator drum discharge lines are near furnace decking or ground levels.
002240 183906
-5-
Area ^2
An acoustical plenum chamber should be installed under the base of the Rerun Tover Reboiler to reduce burner air intake noise. Air intake mufflers should be installed on electric motors for pumps G-H9 and G-2427-A and alike pump motors.
Area ^3
Gear box and compressor heads should be enclosed on compressors G-251, G-35I/751, and G-651. The windows should be removed from the compressor deck control room because they offer no protection from an explosion and leak noise into the control room. Noise levels are just under 90 dBA, much too high for a control room area.
Area
Suction piping from compressor G-o5i, located in the understructure, should be enclosed with an acoustical barrier. The noise levels produced here carry into the adjacent areas. Air intake mufflers should be installed on pump motors located by the lov Pressure Condensate Tank. Other pumps to be considered are G-302, G-2303-A, and alike. Acoustical lagging is suggested for noisy turbines like T-iio and T-117. Noise levels need to be reduced in the operator's shed to below 80 dBA.
Area #5 and 1
No acoustical treatment of equipment is suggested 'until Areas #3 and #k noise levels are reduced.
Area #8
The cold train expander valve should be enclosed with an acoustical material.
Hot Train
Furnace burner noise could be reduced with the instillation of quiet-type air intake mufflers and orifices. An acoustical plenum chamber is suggested for the air intakes on heaters 3-21Q2-A and B. The valves for venting to the atmosphere should be enclosed because they are leaking noise.
Suction piping to compressors #1, #2, #3* & A . and the piping on the west end of exchanger 2106-A need acoustical lagging.
Benzene Unit
Air intake mufflers should be installed on noisy pump motors like M-216 along the main row.
Boiler House
The deaerator drum air discharge pipe should have a muffler installed to reduce the continous 118 noise level. An acoustical block barrier should be installed around the blower intake for the boilers.
002241 183907
-o-
3. Aromatic Vanor Bamling
A. Method
Breathing zone and work room area air samples were collected by drawing air through a charcoal tube with a calibrated Sipia sampling pump about 50 cubic centimeters per minute. Breathing zone samples were collected by placing the pump on the worker's belt and clipping the charcoal tube to his chest. The collected samples were sent to our Pauisboro R & D labora tory where benzene, toluene, butylene, propylene, and total aromatics were extracted with carbon disulfide and analyzed by gas chromatography and reported in milligrams total weight.
B. Results and Discussion
The results of the air samples are summarized in Table II. This data indicates that the employees are well within the TLV for each individual aromatic vapor sampled during the survey. However, if the effects of the aromatic vapor mixture is considered as additive, then each employee exposure is evaluated by the following formula: C/T + C^/T]_ + C2/T3 ... equaling a mixture unity limit value of (1).
C = Concentration of contaminant sampled. T a TLV of contaminant, ppm or mg/M-3.
The samples taken in the breathing zone of men filling rail tank cars, trucks or barges, and unit operators were well within the limits for an aromatic vapor mixture. The only sample which can be regarded significant, was the general area down wind from the product shut-off valves on the wharf, which was 0.76 of the mixture unity limit value of (l).
Organic vapor NIOSK approved cartridge respirators have been issued to loading rack operators. They were located in employee lockers and were of no benefit to a worker when a spill occurs. It would be better to install a window cabinet with loading facilities that could be sealed. When the seal is broken, the respirator must be cleaned and have new cartridges and the old ones discarded.
A permanent drainage system needs to be installed at the rerun tower bottom truck loading facility. Spilled materials have soiled the surrounding area from the excess material leaked from the loading hose.
U. Environmental Sanitation
Toilet and handwashing facilities were inspected for their repair and sanitation, and were found to be in good condition. The kitchen facilities and change rooms were adequately lighted, kept clean, and free of toxic chemical storage.
The maintenance area is over 200 feet from a permanent toilet facility. The employee lunch room is also located in this area which has an insufficient amount of handwashing space. Rosendahl employees are provided with only cold water for washing. There are two portable non-water toilets in the area, for 80 maintenance employees, with about 10 workers usually working full time in this location.
183908 002242
5 Housekeeping
A. Results and Discussion
Except for chemical drum storage in the process units, housekeeping vas very good inside the unit battery limits. The instrument and maintenance shops were found dirty with unorganized storage of spare parts. Garbage hew accumulated behind the fabrication shop at the part storage area.
6. Hazardous Process Chemicals
A. Results and Discussion
work stations in the water treatment section of New Hot Train in the Ethylene Unit were found unsafe for handling corrosive materials e.g., hydrazine. A wooden platform three feet in height without stairs located at a mixing tank vas so situated that an employee would have to lift a five gallon bucket to this height before climbing on top the platform.
Chemicals in fifty gallon drums were scattered throughout the units which did not match their specific injection station. Most of the new slurry injection tanks were not identified for their contents and specifically, handling precautions of hazardous materials were not stated.
In another area, a pump was leaking 1% NaOK solution which was not restricted by a barrier. This area should have been restricted to authorized-personnel only.
7. Asbestos
A. Results and Discussion
Warehouse storage was checked for asbestos-bearing insulation and found free of this material. The asbestos vicking stored in the warehouse is not asbestos free and should be stored in plastic bags. Even though worker exposures are considered nill, a respirator should be used when handling this material.
There is no general written policy for removal of old asbestos-bearing insulation, which includes handling and disposal.
8. Ultra-violet Radiation
A. Results and Discussion
Workers in adjacent areas to the welding operations in Mobil and Rosendahl fa&rication shops are not protected from ultra-violet radiation produced from welding arcs.
RLW:rma
Russel L. Witzke Industrial Hygienist
002243 183909
cs = U sin g p r o te c tio n ; No = n o t u siD g p r o t e c t io n . !o ::ito r re g is te re d sovind le v e l g re a te r than 115*
1
Ho P3* 0o cr *<2r* V O oa' C fl 0 a 0o *>*-# 3P=-3* i w * h-<< v o' 0
ro X >o wo <c-J a
VO VI
o
VI
H i-< -- O
co
rn ro vi -*
*.55 CpO 02 *3 I
0
H r-*
o vH1 i .
-jo--*lJ VHo1J*T
r-' * r-' r-4 oooo I--' f-- 1--' r--'
VI ct*uj
1 VI
VI VI
--V*4 -V*4 ~V*4 "V-4I
r-* H oo p^-ur-/^ V--NI VI
oo r- M rw --Vv3 --V4I
r-^ c- 01 O| MH --| L|O V--4I V*-4I
!> > > ro ro 0 a a a ' -="*4fc ON CT\
o H
'
To3 o fcDr
'Oo ro pcr
o 00
` 1 *1
--
ci
wWcaa
-l Q
>-1 > 3> 3> a a oa aaaa ^ ^ atfc
oooo o 'O *0 *o ra a a a X M *1 '1 acr acr acr car oooo 1111 Ss3: =330 3s3: w2s0:
>> *1 *T QO aa
OJ UlJ
oo oo 33 T3 *0 1O *fwO1 03 W oo 1 *4 OO (0 fi> Pcr cPr o-1 o^
> >*-r OO aa Slfc ro ro oa *oo O0 X1 acr aO' oo
s: a: co cn
s^ >1 aa aa 5t: 55*5
*QMo0 T(roD3j car acr 00
C-i t, 505 2w.
O C3 >=c 5s:
ww
NO VO CD VO CD CD VO
Q ro
ro v) VI CD
ro vn vHi r-o
M
X*
HH
XT' X*
HX** HX* 0t-31 X"*"
i* >
fOO
u> ro oo
u) ro vi oj
ON o . VI O
VO VO OH ro cd
03 "
ro oo s' a
0 3 VO uXj-Uro3 HH 00 00
oo
vo vo oCT --ro4 `
H H*
00 X* I*
VI oo
on o
on ON 00 Ho- H03 H00
H ro HONHO CCOO--X1
H H-* NOO O0O3
on vo
H03 H00
03--3
XX
XX XX
a cpr 0
cQCoO? W C* *o o
CT O' H4"
o
3
CO "3
Hr s(3*
CCQT t>---5
O3 o a
so
m
HD*
(3
W
H WXo
*-+Ui
HJ (9
K (H3
K 3 KKKK no a <9 a n
03 Q3 o w
KK 00
a CO
2523 oo
K =f a(V o
LCC
(I? w
P m< *FOt*<3it 9)
"0 d rj r-1 0P o3 Q cr W cn
O *5
C-- H* O
t-* < cr'
3 >-
cn
cr 0
3
t-*
G S
&5
cr Ho
<< P
i--'
Q
3o 0o
3 C *"C
Kcr*
TJ
ro cr
O
O
o
p
M C5
3
0d3* 1 ro Wcr
cr
S? N 3*
CD 0
a 3PD5i
H
VO
ca
O oO tv. C
u.
oCTj cz
3O3
73
C*3
W
5
t83910
002244
183911 002245
P la n t: M o b il Chem ical Company, P e tro c h e m ic a l D ivisio n
Process o r U n it: E thylene U n it
By: R. L. W itzka
In s tru m e n t: G eneral Radio
..
s = U s in g p r o t e c t io n ; Ho = n o t u s in g p r o t e c t io n ,
r . it o r re g is te re d so;md le v e l g re a te r than 115-
.iu
MOBIL OIL CORPORATION
Noise Survey Bata Sheet
Plant: Mobil Chemical Company, Petro chemical Division
Area or unit: Ethylene Unit
Late: 13 October 1975 Study 3y: R. L. Witkze
Operating Conditions: Normal
Instrument: General Radio 15o5-3
( } Time {
1
I
j l
Location of Microphone NEW HOT TRAIN
Weighting*
Network A1C
(
[ 1
11:30
* Zw 11: 3U ! 11:35 ! 11:36 , 11:38 i 11:10
! 11:42 11:11
I
11 r}
,X1-1-.J:14t 50S
1 12:52
| 12:53 ! 12:51
12:56
13:15 13:16
13:18 *
13:20 13:22
13:23
13:21 13:25 13:26 13:2T 13:28 13:29 13:30
Under furnace 2301-3 Motor for pump ^G-2133-A East side of drum 2101 East side of filter 1-2106-0 East side of drum 2120 Fuel gas valve ?CV 2201-D Burners on furnace 2301-E 3urners of furnace 2301-L Ground level oetveeri
furnaces 2301 B 4 C Fuel gas valve PCV 2201-3 Ground level between furnace
2301 A & B Under heater 3-2102-3 Under heater 3-2102-A Steam valve PCV 2l3l Turbine for boiler feed pump
G-2107-3 East side of drum 2201 Valve PCV 2l23, vent to
atmosphere Under-east side of compressor
deck East side of drum F-2203 Under center of compressor
desk Under vest side of compressor
deck Turbine for compressor Compressor 81 Compressor 82 Compressor 83 Compressor 8k East side of drum F-2101 West end of exchanger 2106-A
(piping)
93 89 95. 91 91 ' 97 95 97
92 98
97 101 107''
95
96 91
99
99 97.
102
95 97 97 97 96 96 92
106
94 91 95 91 91 97 95 97
92 98
97 10U 109
95
90 91
99
99 97
102
95 97 ' 97 97 96 96 92
106
'
Remarks
J1|
(
( i 1 ! 1
* Sound Level Meters response at d3A-Siov and dBC-Slov.
183912'
00?2.1C-
aOmm -JUo. ^ u021"u**lVfcSC /
MOBIL OIL CORPORATION
Noise Survey Lata Sheet
Plant: Mobil Chemical Company, Petro chemical Division
Area or Unit: Ethylene Unit
Late: 13 October 1975 Study 3y: 3. L. Vitske
Operating Conditions: Normal
Instrument: General Radio 15o5-3
1 j Time |
Location of Microphone
i 1 AREA #8, COLD TRAIN
Weighting1* Netyork A1C
Remarks
j 13:50 i i 13:52 J 13:53 | 13:5b j 13:56 i
i1 j 13:59 ( lb: 00 j lit: 01
lb; 02 lb: 03 lb :0b lb: 05 lb:0o lb:08 lb: 09 lb: 10 lb: 12 lb:13 lb:15 lb: 16
lb: 17
lb: 18
lb: 19 lb: 20 lb: 21 lb: 23 lb:25 lb:26 lb: 50
Control panel for gas expander G-2357
Expander valve Pump G-2302-A Control valve TRC 5289 Exchanger 2301
103.
91 102
95
103 111
91 102
95
AREA
Pump G-2b28 East end of exchanger 321 Pump GbOl Pump G-2303-A 3etveen turbines Ho & 117 Area #b operator's shed Drum boi Pump motor G-302 L. P. condensate drum Pump G-2301-A Pump G-2306-A West side of drum F-o01 Between drums ?-808 & F-30b Between drums F-70b and 703 Control valve PRC-306, west
side under compressor deck
1st 6tage suction, compressor G-651
3rd stage suction', compressor. G-651
Compressor b51-A Compressor b51-3 Compressor b51-C Between F-6ob & ?-605 West side of F-603 Inside analytical shed Air compressor station
90 92 95 96 99'' 93 92 97 98 93 9b 93 98 102
107
lib .
Ill 108 106 10b 105 103
86 97
90 92 95 96 99 93 92 97 98 93 9b 93 98 102
107
lib
111 108
' 106
10b 105 103
86 97
1
.
Windows open Pumps
Under structure Under structure Under structure Under structure Under structure Doors open
l1 !I ij i
i 1 1
1 1i( i i i j i j 1
l
* Sound Level Meters response at dSA-Slov and dBC-Sl783913
002247
MOBIL OIL CORPORATION
Noise Survev Data r.eet
Plant: Mobil Chemical Company, Petro chemical Division
Area or Unit: Ethylene Unit
Operating Conditions: Normal
Date: 14 October 1975 Study 3y: 3* L. Witzke Instrument: General Radio 15o5-3
1 j Time | \i j--
Location of Microphone
ii AREA tf1 4 #6
I Weiglrcing* Net:/ork
: A' C
; 9:10 j Areas #1 operator's shed
91 91
! 9:11 ! 3etween furnaces A 4 3
110 no
, 9:13 } Peed piping to furnace 3
102' 102
; 9:l-i J 3etween furnace C 4 D
106 107
s 9:15 Furnace C stack, ground level L02
j 9:17 Furnace G stack, ground level 108
j 9:13 3etveen furnace F 4 G
no
102 108 no
: 9:19 Between furnaces X 4 L
108 108
1 9:21 Between furances R 4 S-
107 107
I 9:23 Area #6, operator's station 85 85
! 9:27 Between furnace 3-102 C 4 D 105 105
9:28 3etween tumps G-4G4 4 turbine
118 96 96
! 9:29 West side of drum D-403
94.: 94
9:30 Pump G-805
99 99
! 9:31 North side of drum F-2C9
99 100
9:32 Pump 106-3
96 99
9:33 Gas oil filters, west bank
94 96
9:3** West end of exchanger 107-C2 97 . 97
9:35 Pump G-4l4
95- 98
9:37 West end of exchanger E-107-
A2 91* . 95
9:39 West side of,tower D-101
88 93
9:^2 Quench boiler deck, furnace
B-101-A
104 104
9; 44 Furnace B-101-F, quench
boiler deck
97 97
AREA #2
11:11 11:13 11:14
11:15
Drum F-2491 Rerun tower reboiler Between heater 3-401 4
B-201 Between drum D-409-3 4
D-303-A
.85 87 104 104
96 96
90 91
Remarks
1
i
i Inside, window open! ,i
I D not in operation |
j i s i ( 1I11 i i .1 1 i1 !
Steam discharge *
1
* Sound Level Meters response at dBA-Slov and dSC-Slov.
183914
002248
MOBIL OIL CORPORATION
Noise Survey Data Sheet
Plant: Mobil Chemical Company, Petro chemical Division
Area or Unit: Zthylene unit
Date: 14 October 1975
Study By: R
*vitzxe
Operating Conditions: Normal
Instrument: General Radio 565-3
1 rr>4 _
Location of Microphone
11
i 11:17 West of drum D-450-3 i 11:18 Carbon disulfide tank | 11:19 Drum F-2204 ! 11:20 Zasu side of drum P-208
11:20 Vest side of pump 2407 1-1:21 West side of pump 102 i 11:22 Zast side of tover D-4o6 11:23 Past end of exchanger 415-3 11:24 West side of tover D-405-A
11:25 Zast end of exchanger 2415 11:26 Pump G-419 11:27 Pump G-2427-A
AR2A #7
11:35 11:36
*W( 11:38
11:39 11:U0
11: i*l 11:42 11:43 11:4U
Aisle N, drum P-8c6
South side tover D-202 South side tover 201 South end of exchanger 208
or Pump G-2424-3 North side of tover 404 Aisle betveen G-405-3,
pump 421 Drum 601 South side of exchanger 201 Aisle east of drum P-202 Betveen lube oil pumps
G-251 4 G-351/751
13:45 Under compressor structure sour oil drain
Weighting*
Netyork AiC
l 1
89 87
89 92 Q4
I 94
! 93 95 90 96
95 96
89 89 91 . 92 95 94 93 .95 91 96
95 96
....... Remarks
93., 90 90
93 92 92
90 93 90 93
94 96
96 96
95 96 94. 95
102 102
106 106
Under compressor structure
l 1 I (1
f (! j 1 1 1 {i
ii1 i J j
i
1
AREA #3
13:48 Gear box for compressor G-251 111 111
13:45 Gear box for compressor
/
G-351/751 13:50 Compressor head G/351-751
103 1Q3 106 106
1
* Sound Level Meters response at dBA-Slov and dBC-Slov. 181915
002249
M03IL OIL CORPORATION
Noise Survey Tata Sheet
Plant: Mobil Chemical Company, Petrochemical- Division
Area or Unit: Ethylene Unit
Date: 1** October 1975 Study 3y: H. 1. Vitzke
Operating Conditions: Normal
Instrument: General Radio 15o5-3
\
* Sound Level Meters response at d3A-Slov and dBC-Slov.
183916 002250
MOBIL OIL CORPORATION
Noise Survey lata Sheet
Plant:: Mobil Chemical Company, Petro chemical Division
Area or Unit: 3enzene Unit
Date: 17 October 1975 Study 3y: S. L. Witzke
Operating Conditions: Normal
Instrument: General Radio 15o5-3
1 | Time
j
Location of Microphone
i i
I 11:15 1|1 11:lo i 11:17 ! 11:18 ;
Center of control room North 3ide of control room Betveen Q. C. Lab and trans-
formers South end of pump aisle Betveen motor 432 and turbine
G-2
Weighting* Network A1C
So 62
69 90
90- 91 90 91
90 91
Remarks
11:19
11:20
11:21
11:23 11:21* 11:25 11:26
11:28
11:30
11:31 11:31
11:33
11:35 11:36 11:37 11:38 11: 1*0 11:41 11:1*3
11:45
West end betveen exchangers
344 Control valves vest and
90
betveen Tovers D-102 4
D-105
91
Betveen Tover D-1Q1 4 Control
valve FRC-114
92 s
East end of exchangers 106-A 93'
East end of exchanger 117
94
East end of exchanger 122
92
Aisle center, betveen motors
241, 229, 4 228
94
Aisle center, betveen motors
246, 245, 225, and 227
91
Aisle center, betveen turbine
103 4 motor 484
96
Motor 216
102
Center aisle, east of motor
216 95
Center aisle, betveen motors
256 4 434
92
West end of exchanger 308
93
West aisle of tover 305
95
West side of tover 302
39 ..
Under benzene heater
89
North side of compressor G-305 96
North side of compressor 305-/ 96
North side of compressor motoi
302 96
Air compressor
91
90
91
94 95 94 94
96
92
97 103
97
93 95 96 90 90 97 93
98 92
,
Air intake
\
ff 1 Jj 1 i
11 1 (l1 j f
* Sound Level Meters response at dBA-Slov and dBC-Slov.
002251 1S1917
M03IL OIL CORPORATION
Noise Survey Data Sheet
Plant: Mobil Chemical Company , Petrochemical Division
Aren or Unit: 3oiier House
Date: IT October 1975 Study By: R. 1. Witzke
Operating Conditions: Normal
Instrument: General Radio 15o5-
i Time
Location of Microphone
Weighting*
Neti/ork
Remarks
AC
10:55 1i
Control valves southwest of boiler
j' j
10:56 j South side, motor for air : blower for boiler
{1 10:53
Turbine for air blower for boiler
1 11:00 North side of air preheater
1 11:02 Boiler I'eed pumps
1 11:03 Control panel, 1st level
| U:CU Bottom of deaerator drum.
11:06 Top of deaerator drum
11:10 Inside control room
t
93 9k
102 . 107
112 113 95 102 9h 95 9k 95 95 95
ns 118 65 78
.^
j i i ji
*
! i
j
i \ j 1 |
' /
\
* Sound Level Meters response at d3A-Slov and dBC-Slov.
002252
183918
002253
T o ta l H y ih r> rr,rb o 'is . X y le n e , B u ty le n e , P ro p y le n e v e re n o t d e te c te d "by a n a ly s is
i
V
V.I
i^ N I -i
Sound L e v e ls &BA
!'r f 31IKK 2
n-i - \:
I
i I.:(:rc t vfif 7' "* j v ,ff f- i nti ;
I, `c^r.^-T
,_J.J
N 1 2 V .. n I ^ * l$5
~ v i:)rNL
"S
/Si' '
<*,
rOi i; _______J_ i, -n^- - - --n.- -
-.
. \._
_______ .
r.onrvl le v e ls riBA
-r~kfcJV
r^(7rA':-
v*
jr-r^sr -- ~'*'U =V`
Vi/f**s** K% __ ___
* -jc u .J
L~J
,
X
I * *Vl! * ?!,]*
| ,, I i,I- I ^
: r-^SfTfcr 1 p; ,
^;i -
g^yj.J.- t ,____1.1.1.:-,, : brv~.*~' - 1 - --T.eI s
^^-4..r>jg=n{r j^;/; r -
.<<-/. | (/r~t--~~ ? 1 *^*py ^
;l`
..lg^cSris-r8*-.---------------- - -M
;
1
t.
?/> 1V. _/
I aiii-11
c,
. 13392100225'5
--a.. a.'
AJ'v2,*:
v*
\
'
,,
. *'\! t
v' -*
. i . r1
t j
2'
i
*
v .'!;
v,
v
t :>
V;
'*/,,
* -yi` * r *-*<../
'........... Vv\v/(*--*101 4 -- .--V j<-*.-.*r f-Tjr*?r',=v
,
.r |J
. : r
^-TtA***
* /A ' /! ' ,c." --r--*t* -.,--/ *
' . c,. '
V / A ,
f
< , --- -y-&
j;
r
V'
1
.
.... \ ;=":
i ^i jrx.ungr .yfj \rn
^ --TJ* 'X ,`V-. t\|l t |i\r
l m y ij ' m :]
'' \Jy/" , J (
S;-*
l! -r--l:;,r.lT -- ,.V...
j: ,ii "v i :
. !/sr> i ? !j u x~yV"`t1.6 ^
I V w; ,
I4
*~-i jj_-
{ U/#/7\j.SJM\3
1
*-- ( - ---- *
I
I
%'*
------------- r --^
JS--------------- ------------------------------------------------------------r---------------------------------
i__ i j . j__ i i
-3--'~r---------,
-N'fl Vr-sy.?^!
^ J r9(yKrw>T..
J/V '183922
"*l 'i l
I - 4
ti
002256
H 'filO .l p A f/'/C O y
SN S 'l
I * aJ\W'S i
>.
------<'V-- '''Vi1/---- --- r----------
, ---
/..";! ------ ,<l,r
if*- jc tios*.--
---.`i: . ; -yA'osp/ ,,
1
________ -r E /.'.--A ci. ; ?- ;
' '
J r. ?-n-------- '
. o.'i-
,,
_V-V^ ' ( Z/! r.i. veio
\ *4 7,<SdA z::z-----------r n:: . . :u * t-u
; 77, 1 U
_< F-2'/V
`"U r.u. iv. I0a'<0*
r-0U.CM. ''o' 7 __<,* ^$&==r ^r* >-
': TM `'Z~~,,~~T-rrr;. r ^c~ .1
z
u- ^/C.OA
:*:<!&> /lfh! 1 vl/ j
iCiii-i"
."* -- *<7\ ^ `-(i
- - -------------- 1
0*
________l'. j\Z-i<'0Z. .. 7*. .:.
_______________ ^,4 tU.ICS'-O* o -
T *5 ^>` 1.T:
r,r_
'^s i-'
;Z>
t-S-tf'^V-
--
\>6)-x.'+
------ ('
,t _n; r/Tj1- v
64--0" ' "'.....................
'
g'?ZCIA _ 'El.lO/- G"
?. ': "
r; ,
* 3;2L?j!B. ,c'C$/f}\_________,l!_z 'it-G'^2l3B
U 107-0-rW y
;;
me,'
I6'-2V."
r" tz
19'0*
l7'-0"
E-220IP.
* >
0,1
fr*
-M
og
-
:
-y---- -w--7-r-v->--;'"- ;-o--re--; *'S.<i j-- 2Q'-0" -i:
a.t.Lw.m.4 j,----- r<". Tw-5--r--.-0----
VV- c*-
pr.* I O; ;
.;_-^_'5c-'2Ci0'Ti3'i'P-'"_b~f'fVf?_7_''__.jyI'i "
A ; TO 16 * C-3'.GI A
1ST,'. ,' 1 1
--?3--@i-
''7,1
i.
* V*w/^
I ^ W.* ,
- - - 4 ?_____ .................... -
5 :P .![]!! `=raS:W(f)^ij j ? @EZ:
7-- ^1P-
--;--;;0 0-0-00-00^-^ .0000 Q;-~Q/T-lI .
1 Ki
Isl U. V'71:
,
<=t t03 Q
i ); ....-.(ry .....::'Z:;' v^[rj|',osA
-----------y*..!
i2 ---
n
27: x 'ryTuRSd-z:
1 2. ^*tOd 3 1 ". m. II"
-- -y- * --rTV I'li
ji. cr
i--7-1--
, .:o, ; ^.r^jojo__ _____ ;__
. 7j ^5.1H2.2.2J-Ii^
''Fkvwo
3-5
W7Q< J4.
VU:
:!
!T
I
e-2l03E
I I'
V----------- --------------- 1---- --ce:
< E-2IQ2E-ITO1 <P-ilOie
. /fSS ..............
! O v v* OU O
C
, (T----------------:--y.a
l!
r .^SN ,!
2_ /Vl-i_ " !!
` *7 STACK *uruc*i-
jf
I1 ! I
rr\
W
2 Vc*T
i
vS-< U
1
j___________ __ a
. 1!
; ---- ... 1
I'
1 '!
L--i
~r 1
--y
fU
'
* ; t1 --^ i| -I iZ.'* u^.,
y- -!i
>A (2s
.1* V-
.? JiA>
4a-2IQAA
. 14&!$4a_xsL -c=. i^<j>
c-.
t .^a=s--(T=
La-0,-;. ^
__<0-2105_______ 3 T i. CL.IIZ'-G"
f E-2I0S____ '1-PC.S.eC.I2S,-6* ---- ---- -F.-2lO<JA ____ !r =*21i '<.(..iO-r-6- Z
----r-i LtL.10-l--6-- If
^L-2106
-t-| lie-2443
iU^EOos^'
o
D
I
H < E 21018 EL-103'-7" ;
4-!'E;uiAEu.ro~-3* , .j n ............. tus4fFv2iIo0s5aA. ELJIQ'--:"
&2tOIA
K*
T3t
4: |
<GZI01 B }**:.
------------ rtiio-ftsa
L. ^ <o.
-E-2J05* EL.I05'-2'";
----------i----------
fife 210sa
~ C u. tO 6 * 6"
--^r'/r&Pv^-:y
s$ir;ot
"^TL. L.
lid'-0``i>j
t-tii0-3-?
* n . JI "
r>j 1
\JEL
`CI..I0E.--6-
-"! i
:,'r,v srnr^-oCiiMiiiS4k.u tsto/s:5 1 c-<l
*
,!
.APPENDIX I
PERSONNEL PROTECTIVE MEASURES TO 3E POLLCl'CD DURING ASBESTOS idIMEVAL CPERATIONS
All asbestos containing insulation trust be thoroughly wetted wit; water bctore removal.
Wetting can be accomplished by any practical means such as hose lines or water spray from self-contained pails or cans.
Wet steam is another possible means of saturation of asbestos if feasible conducted safely.
Five minutes of water application for 2S square feet of asbestos surface insulation area should suffice.
When - asbestos is being removed, a suitable means 'or containment must be used, to catch chunks of asbestos to prevent dispersion of asbestos fibers.'
Employees involved in the removal operation must be equipped with a NTCS.'Iapproved, single-use, disposable respirator; 3-M, Model 8710 respirator meets this standard.
Employees also must wear gloves, coveralls, and shoe covers. Gloves, coveralls and shoe covers, wherever possible, should be of the single-use, disposable type
Employees must not continue to wear this protective clothing if they leave the job site for another activity and specifically when eating.
If noni--<disposable protective clothing is used, the -collection ana ..turc.0 *
procedJuurrees outlined in the Federal Register and Mobil Medical Guide No.C3-13C3 must be followed.
Asbestos-insulation waste, debris and used disposable clothing must, immediate!j be packed in impervious bags and affixed with cautionary tags. The tag shall state:
*
CAUTION CONTAINS ASBESTOS FIBERS
AVOID CREATING DUST BREATHING ASBESTOS DUST MAY CAUSE SERIOUS BODILY HARM
A*
183925 002253
-2-
4. The bagged waste material should be disposed and covered daily in the Refinery landfill. If disposal at the Refinery becomes impractical due to space limitations, a qualified 1 ocai contractor should be used.
S. Proper cautionary signs must be displayed at each asbestos removal or demolition site. The signs shall state:'
, ' '
,. ,.
.
*
ASBESTOS
DUST HAZARD '
;` *
Avoid Breathing Dust
Wear Assigned Protective Equipment
Do Hot Remain in Area Unless
Your Work Requires It
Breathing Asbestos Dust May 3e
. Hazardous To Your Health ' A* '
.
;
Cautionary signs should be placed at a suitable distance (Suggest a minimum of fifty feet) around the removal site, demolition site, and collection point.
Any employee entering these areas not immediately ' involved in the removal of asbestos must wear a minimum of a NIOSH-approved, single-use, disposable respirator, 3-M, >bdel 8710 for protection.
6. It is also recommended that area monitoring be conducted during any 1arge-siccd asbestos removal project to determine the extent 'of pqssible drift of asbestos fibers.
183926 0022S0