and Facilities (National Fire Protection As sociation).
Moving Walks
A moving passenger-carrying device, on which persons stand or walk and in which the passenger-carrying surface remains paral lel to its direction of motion and is uninter rupted, is called a moving walk
Criteria for the design, construction, in stallation, operation, inspection and testing of moving walks installed for the purpose of transporting passengers are set forth m the Elevator Code, part IX
Moving walks may operate in a horizontal plane or in a slope up to a maximum of 15 de grees Operating speed and treadway width are governed by the slope
Comments as to protection of passengers, found m the previous Escalators section of this chapter, apply also to moving walks
Manliffs
The following are the pnncipal hazards in the use of manhfts
1 The rider may be carried over the top
2 He may be unable to make an emergency stop
3 He may jump on or off after the step has passed the floor
4 His head or shoulders may stnke the edges of floor openings
5 He may be unable to reach the landing be cause of power failure and belt stoppage
6 Parts of the manlift may fail or operate un safely
Construction
Manlifts should be constructed, maintained, and operated in strict compliance with the recommendations of American National Stand ard A90 1, Safety Code for Manhfts A safety factor of 6 (based on a 200-pound load, on each step, on both the up and down runs) should be used, and all equipment should be braced securely at top, bottom, and inter mediate landings Steps should be nonslip The entue manlift should be suspended fiom
the top to prevent bending or buckling of the rails
Handholds (either open or closed type) should be painted a conspicuous color, such as orange or yellow They should be not less than 48 m nor more than 56 in above each step, and steps should not be less than 16 ft apart
Floor landings or emergency landings should be provided for each 25 ft of manlift travel Clearance between the surface of any landing and the lower edge of the conical guard suspended from the ceiling should be at least 7K ft The minimum clearance be tween the center of the head pulley and the roof or other construction should be 5 ft
The bottom landing on the up side should have steps to a platform, level with the man lift step as it nses to a horizontal position
Floor openings and shear guards. At floor landings, standard 42-in guard rails and 4-in toeboards should be provided around floor openings m such a way as to permit a landing space at least 2 ft wide Rails or guards should have maze or staggered openings or self-clos ing gates that open away from the manlift (Fig 28-11) At each floor opening on the upside, funnel-shaped (conical) guards should be installed (Fig 28-12)
Brakes, safety devices, and ladders
A brake, designed to be applied automati cally when the power is shut off, should be installed on the motor shaft for direct-con nected units and on the input shaft foi beltdriven units The brake should get its powei or force from an external source The brake must be capable of quickly stopping the manlift and holding it when the down side is loaded with 250 pounds on each step It should be electrically released
A contiol rope, not less than % in , or a rod should be provided within easy teach of both the up and down runs When pulled in the direction of belt travel, the rope or tod should cut off the power and apply the brake A mechanical-electrical device that will automati cally shut off the motor power supplv and apply an electric brake, if the lider fails to alight at the top landing, should be installed
783