Document GjQV6nMLKwzpL00QmjY4ya0V

Monsanto *PMM <NAMl ft LOC WSJtCT V--^ PIIPIMCMCI . TO : COMPANY CONFIDENTIAL 43&t>-- E. E. Stewart, W. G. Krummrich Plant March 17, 1972 POLYCHLORINATED BIPHENYLS (PCB) - SEWER ANALYSIS Messrs. Clarrie Buckley Harry Campbell Bill Caraway A1 Frerking Hap Horner Ron McEntire Ed Stewar t Messrs. Bill Engman Paul Heisler Art Leisy Bob McCutchan Scott Tucker - So. 2nd The addressees met 3/14/72 to review the present method of re porting the amounts of chlorinated biphenyls present in the various sewer streams that are analysed. At present, a chromatographic analysis iB made of the sample. Calculations are made based on peak heights, and chlorinated biphenyls are reported as Aroclor 1221, 1242, 1248, 1254 and/or 1260. The respective amounts of each reported Aroclor are totaled, and this latter amount is used to calculate the amount of polychlorinated biphenyls (PCB's) present in the sewer stream. Each respective Aroclor is a mixture of different chlorinated bi phenyls. The lower Aroclors contain more of the lower (mono) chlorinated biphenyls, and the higher Aroclors contain more of the higher (poly) chlorinated biphenyls. Some Aroclors contain the same components. In tl^ose cases when the component used for peak height measurement is present in different Aroclors in the sample, we are double counting. This is true when 1221 and 1242 or 1242 and 1254 are reported. Orthochlorobiphenyl is common to 1221 and 124 2. It was agreed by those present that the laboratory would discontinue reporting specific amounts of 1221 and 1242 present unless a dis proportionate amount of 1221 is present. The analyst would make this judgement. This will eliminate double counting when both 1221 and 1242 are reported. At this time we will continue reporting 124 2 or 1248 and 1254 or 1260 separately even though there is a slight overlapping of some components. There was some question when we began producing 1105 and 1109 whether we should report monochlorinated biphenyls as PCB's in the sewer streams. The guide given by W. B. Papageorge was "if the amount (A-1221 or a- 1109) begins to exceed the amounts of other PCB's present, we should report as PCB". HONS 042690 Clarrie Buckley Hap Horner Harry Campbell Ron McEntire Bill Caraway Ed Stewart A1 Frerking POLYCHLORINATED BIPHENYLS (PCB) - SEWER ANALYSIS ' p*ge 2 WGK 3/17/72 Therefore, using the above information as a guideline, I suggest: 1. When peak heights would indicate the 1221 amount to be less than 1 242 or 1248 and 1 254 or 1 260, do not include 1221. If the peak height would indicate the presence of some 1221, so state on your tabulation sheet. 2. When peak heights would indicate the 1221 amount to be greater than 1 242 or 1 248 and 1 254 or 1 260, include 1221 as a separate Aroclor being present. Please note the attached table. Based on previous analyses, I would recommend we count or not count as I have indicated. Edward E. Stewart /emc att. mqns 0426" REPORT PRESENCE OF 1221 X X X X X X X X AROCLORS 1221 292 ppb 440 15 80 103 31 311 607 17 25 95 48 534 2697 121 31 1920 3985 728 21900 22300 5061 4 21 46 114 9 51 22 392 1242 or 1248 1 59 ppb 641 22 73 189 45 288 727 21 61 122 64 823 1923 209 36 1320 7148 268 406 7 12 78 190 29 59 18 205 1254 or 1260 15 ppb 224 7 50 70 7 127 245 8 22 52 15 174 184 10 " 3743 140 50 39 70 2 17 180 60 21 18 7 95 DO NOT REPORT PRESENCE OF 1221 X X X X X X X X X X X X X X X X X X X X X X HONS 042700