Document GRyJYNJ8RkKMV7bnBD4Me9ZN

American Society of Heating and Ventilating Engineers Guide, 1928 Table 6-J. Coefficients of Transmission (U) of Various Types of Masonry Wall Construction Note.--These coefficients are expressed in B.t.u. per hour per square foot per 1 deg. fahr. difference in temperature between the air on the two sides and are based on an outside wind exposure of 15 miles per hour. CoiJchete Block, The value? of U.ui this Table are based on the /bllowmq Internal Conductivity? CO which arc expressed in 6.t.u. per Ur.; per 5q.ft. per FF . Concrete blocks 4.84* per l" Cement Mortar 8.00 per i* Plaster board. 5.04 per F Plaster (Gypsum) - 2.32 per l- Wood Lath 4 Plaster 2.00 as applied Cort.board 0.30 per l* Fiber Insulation tboard/oren) 0.33 perl* Cellular Gypsum (Ae.*) 5S per 1* Powdered GyfJWi (26*) ' 0.52 per f v/alls ' 0 vi C UrMcj v; Y -Thickness of Insulation vvher Specified .o Interior Construction 11 100 Plain Vails - Uo Interior Firmh Thickness, of Concrete blocks -.T YG a 8' 10' \t' bCd 0.444) 0.377 0;327 0.287 101 \ Plaster on Concrete blocks 0.408 0.348 0.305 0.271 102 ^Plaster on Metal Lath - furred 0.247 0.224 0.205 0.1.89 103 X Plaster on Wood Lath - furred O.Z36 0.215 0.198 0.183 104 d plaster on Plaster board - Furred T Plaster on Wood' Lath on 2' furrinq 105 `strips - Cellular Gypsum Fill X Pi aster on Wood Lath on 2* furrinq ^ too strips - Powdered Gypsum fill 107 T Plaster on Fiber Insulation -- (board form) Furred 108 109 jr Plaster on Cork board set in vZ Cement Mortar 110 0.Z46 0.2Z3 0.204 0.188 * 0.182 0.169 0.158 0.149 '* 1%' 0.171 0.t59 0.150 0.141 &' 0.183 0.170 0.159 0.149 r 0.143 0.135 0.128 0.122 \i 0.133 0.126 0.120 0.114 i' .0.109 0.104 0.100 0.096 Based on 1% in., the'actual thickness of 2 in. furring strips. / fThe figures on this page may be used with sufficient accuracy for concrete block walls with stucco' .- exterior finish. -i- ^^Resistance of hollow concrete blocks = ( = ---- assumed directly proportional to^thickness as \ c 4.84/ with solid homogeneous materials. 30 Table 7-A. Coefficients of Transmission {U) of Various Types of Frame Wall Construction Nnte__These coefficients are expressed in B.t.u. per hour per square foot per 1 deg. fahr. difference in temperature between the air on the two sides and are based on an outside wind exposure of 15 miles per hour. Wood SioitJq 02. Clapboard walls f The values of U in this Table are based on the /bllowmq Internal Conductivities (C) which are expressed m b.t.u. per Ur. per Sq.ft-, per Wood (Yellow Pine or fir) ' 1.00, per l" Plaster (Gypsum) Wood Lath ( Plaster Plaster , board 2.32 2.00 3 04 per 1* as applied -per 1* Cork board 0.30 Fiber Insulation (board/brm) 0.33 per 1* per-f ffelt or Quilt Insulation (S</t) 0.2 7 per l Ce-lluJar Gypsum (i&*) 0.54 per f Powdered Gyp5um (26*) . 0.52 per l Typical Const ruction ohealhtnq W ood uds^ ___ / ((N-*.r V _o l3 -21. Type of Sheathmq Ill Wood III Wood * 113 Wood 114 Wood * 115 Wood * * lib Wood in Wood* 118 W fiber Insulation (board form) i* Fiber Insulation in (board form) yfr Fiber Insulation 120 (board form) 121 Plaster Board Insulation. between Studdinq Plaster base Done Wood Lath fe* felt or Quilt * Insulation 1/1* Fiber Insulation * (board form) . Cellular Gypsum fill * Powdered Gypsum fill Wood Lath Wood Lath Wood Lath Wood Lath Coe/^icient 0/ Transmission U 0.227 - 0.129 0.135 0.110 * 0.101 Done . i)z Cork board 0:il0. Done Z" Cork board Done Done VC fiber Insulation t (board form) It fiber Insulation (board form) % fiber Insulation (board form) Yi fiber Insulation (Board form') Done 3/fe Plaster board 0.093 6.157 0.127 ' 0.107 0.280 Based on H in., the actual thickness of 1 in. or % in. sheathing. tBuilding paper neglected in computations in accordance with accepted practice. ?Can also be applied on inside of studding with plaster base separated by furring strips. Thickness of fill assumed in., based on 2 in. by 4 in. studding. Y- 31