Document GRbo0xJej2GYGD8ZZQL0MZ1N
Section Number Issue Number Origination Date Revision Date Section Test
Ethanolamines/Glycol Ethers
In Plant Training (IPT)
:15 :1.3 :09-01-91 : 12-23-97
:15
Author:
Mike Viator
Ethanolamines/Glycol Ethers Control Module Line-O-Logic
Answers:
1. State what EBV-1036 is. Incoming ethylene oxide emergency block valve.
2. State at what pressure EBV-1036 will alarm on low pressure. 70 psig.
3. State at what pressure EBV-1036 will trip on low pressure. 50 psig.
4. State what EBV-1041 is. Incoming propylene oxide emergency block valve.
5. State at what pressure EBV-1041 will alarm on low pressure. 50 psig.
6. State at what pressure EBV-1041 will trip on low pressure. 20 psig.
7. State what EBV-2072 is. Aqua ammonia emergency block valve at MX-201.
8. State two ways to open EBV-2072 after it trips. Put on manual in the field or go on bypass and hit reset button.
9. State at what percent of chart will EBV-2072 trip on aqua ammonia low flow. 10 percent.
10. State what determines R-201 low NH3/EO ratio trip.
Date Printed: April 18,1998
Paper Copies Of This Document Are Uncontrolled & Not Subject To Update.
The Controlled Document Resides In File: T:\ORIGINAL\IPT\EAGECONT\LINOLOG\ASOSLOG.DOC
Page 1 of 3
^ 058627
CONFIDENTIAL
HIC-2075A
11. State what the low NH3/EO ratio trip setting should be. No less than 1.6.
12. State what valves trip when P-201 shuts down. EBV-2077 and EV-2071 (oxide control valve).
13. State what happens when TS-2072 is energized (the total emergency shutdown button). A. P-212 continues running on total recirculation. B. EBV-2072 closes at MX-101. C. P-201 shuts down D. EBV-2071 closes (EO emergency block valve at MX-201). E. EV-2071 closes (EO control valve at MX-101). F. P-205 shuts down G. Anhydrous ammonia to D-210 closes (emergency block valve). H. Anhydrous ammonia to D-210 closes (control valve). I. Suction valve (EBV-2009) closes.
14. State everything that will shut down P-101. A. Low oil pressure B. High vibration (if not bypassed) C. High discharge temperature D. P-106 shuts down E. P-104 shuts down F. Low catalyst flow
15. State two things that will shut down P-106. A. Catalyst line differential pressure (10" of water). B. Catalyst line high temperature (alarms at 50 degrees, trips at 75 degrees).
16. State what the low pressure alarm/trip is on the feed to R-101. A. Alarms at 240 psig B. Trips at 188 psig
17. State what the low pressure alarm/trip is on the feed to R-102. A. Alarms at 125 psig B. Trips at 100 psig
18. State what the high temperature alarm/trip is on the catalyst line to MX-101. A. Alarms at 50 degrees B. Trips at 75 degrees
19. State what the high pressure alarm/trip is on the feed to R-101, R-102, R-103. 650 psig alarm and 700 psig trip on all three.
Date Printed: April 18,1998 Paper Copies Of This Document Are Uncontrolled & Not Subject To Update.
The Controlled Document Resides In File. T:\ORIGINAL\lPT\EAGECONT\LINOLOG\ASOSLOG.DOC
Page 2 of 3
00 A 058628 CONFIDENTIAL
20. State what the high temperature alarm/trip is on P-101 discharge to R-101.
60 degree alarm and 80 degrees trip. 21. State R-201 high/low pressure trip settings.
High pressure 975 psig, low pressure 500 psig.
Revisions:
Revision No. 1
07-15-93
Yearly Review
Revision No. 2
12-18-94 12-18-94
Yearly Review Added 14F & changed 16A & 17A
Revision No. 3
12-23-97
Yearly Review
Date Printed: April 18,1998 Paper Copies Of This Document Are Uncontrolled & Not Subject To Update.
The Controlled Document Resides In File: T:\ORIGINAL\IPT\EAGECONT\LINOLOG\ASOSLOG.DOC
Page 3 of 3
DO A 058629 CONFTDFNTTAL