Document GQOrvpX2aJ0J1zVb06zqEQVq

41--Electrical Hazards played near exposed current-carrying parts and in especially hazardous areas, such as high-voltage installations These signs should be large enough to be read easily and should be visible fiom all approaches to the danger zone They should meet American National Standard Specifications for Accident Preven tion Signs, Z35 1 In many respects, standaid machine guaidmg practices can be applied to electrical equipment There are, however, certain haz ards peculiar to electricity which must be given consideration when the overall plant guarding progiam is planned Wiring should be installed m accordance with the National Electrical Code unless more restrictive local requirements apply The type of wiring that should be used in an industrial plant depends upon the tvpe of building construction, the size and distribu tion of electrical load, exposure to dampness or corrosive vapors, location of equipment, and various other factors For most plant conditions, grounded ngid metal conduit is satisfactory The various types of insulation used on electrical conductors and their application provisions are given in the National Electrical Code Among wiring methods which may be used under ceitain cucumstances are armored ca ble, nonmetnlhc sheathed cable, flexible metal conduit, raceways, open wning and insulators, and concealed knob and tube wiring When new installations are made or existing cucuits changed, applicable requirements of national and local wmng codes should be observed Wires having insulation designed foi the type of service and location should be used, but the insulation alone should not lie con sidered sufficient protection against shock, especially m high-voltage circuits Frequent inspection of equipment and competent supei vision of maintenance crews are extremely important, and the mspectois' reports will aid the safety piogram consideiablv Often in their routine work throughout the plant, maintenance men can spot hazards before thev cause injuries Motors should be mounted so that thev do not interfere with the normal movement of personnel or materials Nonenclosed motors should be m areas free from dust, moisture. 1260 and flammable or corrosive vapors In some instances, they can be isolated from personnel by being mounted on overhead supports, installed below the floor level, or placed m special motor rooms If current-carrying parts must be exposed, they should be made inaccessible by elevating them at least 8 ft above the work area, or enclosures, barueis, or guaids should be pro vided to prevent contact Switches Among the several types of switches are pushbutton switches, snap switches, knife switches, and enclosed externally operable air break switches Switches designed foi eonti oiling individual motors and machine tools and foi lighting and power circuits are the enclosed type All switches must have approved voltage and ampere ratings compati ble with their intended use An open knife switch should not be used, it is hazardous because of the exposure of live parts and because of the arc formed when the switch is opened Knife switches should be enclosed in grounded metal cabinets having control levers that operate outside the cabi nets A fuither safeguard is the safety switch whose cover must be closed before the switch can be used A knife switch should be mounted so that the blades are dead when the switch is open and it should lie installed so that gravity will not close it Knife switches installed in powei switching cucuits should be elec trically interlocked so that they cannot be opened when the circuit is energized, unless switches are of the load-break type Where it is necessaiy to use disconnect switches foi high voltage, heavy current feeder cucuits to test floors, or other service installations, they should be located out of normal reach and should be operated onlv by insulated switch sticks Where it is imprac tical to locate the switch out of noimal reach, it must be protected against accidental contact by operating personnel, by a complete en closure or suitable fence or bamcade, the switch to be opened or closed remotely by an insulated switch stick Pushbutton or snap switches are recom mended because the live parts are enclosed Flush switches should be installed m metal