Document GNRvnXqz1xaVQ3an989M57oq
Heating Ventilating Air Conditioning Guide 1956
Hot water heating systems
{continued) one-pipe
forced circulation, 540, 543,
MS gravity circulation, 539, 542,
545 orifioe friction heads, 541 pipe sixes, 537-539, 555 _
forced circulation, 535-MO gravity circulation, 535-540
piping design, 542, 555 .pressure head, 535
relief valve, 552 reversed return system, MZ
safety devices, 552 two-pipe
forced, MO, M3, M7 gravity, 539, M6
soning, 552
Human body acclimatization, 118 adaptation. 113, US cold condition, 115
hot conditions, 115, 314 heat emission, 120,314 high temperature hazards, 117
metabolic rates, 113
odors, 113 temperature, 114 thermal interchanges, 113 sone of evaporative regulation,
115 Humid heat, 5
Humidification, 613, 805, 807
control, 490, 914 direct, 807 forced furnace systems, 490^
Humidifier, humidifiers
air washer, 807 atomising, 809 high duty, 809 aeo-oontained, 810
spray, 809 unit, 809 Bumidistat, 5
`
Humidity, 5
absolute, 5 control, 688, 914, 1092 influence of, 122,141
measurement of, 1158 nurseries for premature in
fants, 140
ratio. 5, 25 relative, 5, 25, 699 Hygrometers, 1159,1160
Hygroscopic materials, 1026
Hygrostat, 5, 901
I
systems, 865 Impulse trap, 524-527 Tprn of water, 5 Induction units, 693 -
high pressure types, 693 low pressure types, 692
Industrial air conditioning, 1015
calculations, 1031 ' ,
conditioning and drying,
1027 contaminant control,.lwl
eontrol of chemical reac
tions, 1027
dilution systems, 1032.
general requirements, 1015,
1031
-
humidities, 1015-1026, 1030
laboratories, 1030
local relief, 1033
..
machining tolerance.' 1030
moisturecontent and regain,
1026.
'
polished surfaces, 1030.
process, 1015
Industrial (continued)
safety, 1031 . spot cooling, 1036 static electricity. 1030 temperatures. 1016-1026
exhaust systems, 1041
Infiltration
causes, 227
.
due to wind pressure, 228
heat losses, 266
latent. 268
... sensible,267 measurement, 1158
temperature differences, 233
through outside doors, 229,231
through walla, 228
through windows, 229 .
Inflammability, 162
Inside temperature, 258,259,276
Instruments, 1145
Insulation, 6, 653
_
economical pipe thickness, 667
Savity furnace duct, 463, 464 w temperature pipe, 663
pipe, 653 ' ` ...
pipes to prevent freezing, 665
sound, 950 .
_
thermal conductivity, 657
underground pipe, 667
Intermittently heated build
ings, 270-
Isobartc, 6
Isothermal; 6
J
Jets, 703' expansion, 705 radial, 710 velocity, 705
Joints, duct, 755
Kata thermometer, 1157
Laboratories, 1030
Latent heat, 6, 268, 275 Ins*, 268
Laws of thermodynamics, < Leaders, 463
Leakage of air. 227 door, 229, 231, 232
* window, 229,230,311 light heat gun, 315 Lignite, 333 Liquid
heat of. 5 Lithium bromide, 685 Lithium chloride, 685.
Load cooling, 275. 689.
design, 6,2o9
factor, 461
heating, 243,690
maximum, 6,403, 461
refrigeration, 275
M
Machine vibration, 959 -
Manometer, 6,1150 . Mrinn {see zitp heating, ^renti-
latino,air conditioning)
Mass, 6
Mbh, 538
Mean radiant temperature, 119,
579, 581, 912 :
Meter* meters, 78, 683
area. 78) 85.683 condensate, 683
flow, 78, 85, 683
Meter, meters (continued)
force, 78 ihead, 78,83,684
installation, 683 orifioe, 79, 11M selection, 684
velocity, 684 venturi, 1155 Metering, liquids, 78, 683 Mioromanometers, 1151
Micron, 6 Mist, 162
Moist air. 25 properties of, 25
saturation. 26 specific volume, 32
Moisture. 205, 1026. 1061 content, 1026, 1028, 1062 in building construction, zoo
loss*per person, 122, 314, 892
movement in materials, zu permeability, 212 regain, 1026 transmission, 208 MMoonLo6fluorotrichlorometh. ane,
849,853
Motor, motors, 270,210, 923.
alternating current, 927
capacitor type, 930
classification, 926
control, 934, 937 - - -.
.
control equipment for, 934
current limitation,.935 -
limits, 924
drives, 924
electric, 923
enclosures, 939
glossary, 938 teat generated by, 270
hermetically enclosed, 932 -
increment limitation, 935
multi-speed, 929, 936
polyphase, 927
rating. 936
.
repulsion induction, 931.
selection, 923
single phase, 930 _
speed characteristics, 926
speed classification, 939
speed ranges, 924
split phase, Ml
squirrel cage, 927, 934
starting methods, 934.
synchronous, 928,935
wound rotor, 928, 935
N
Natural draft, 421 towers, 813 . .
Natural ventilation, 235
Eineral rules, 241 eat removal, 237
Noise, noises, 941, 1133 absorptive material, 950 .
air conditioning system, 942,
1133 air supply opening, 955 apparatus for measuring, .942
attenuation, 949 average in rooms, 946
control, 941
'
controlling vibration, 959
cross transmission between
rooms, 958
design room level, 945 duct sound absorbers, 950,952
duet system attenuation, 949
fans, 946
general problem, 942
grille, 956 . intakes, 726
kinds of, 944 levels, 717, 943, 945
loudness, 941
Index to Technical Data Section
Noise, noises (continued) measurement, 942 openings, 955 plate cells, 953 plenum absorption, 955 through building construe? tion, 958 transmitted through ducts, 944 typical sound level, 945 unit of measurement, 941
Nozzle flow, 75, 78
Nurseries for premature In fants, 140
air conditioning equipment, 141
o
Odors. Ill, 113,147,156, 792 human body, 111
Oil Fuel, 340 analysis, 341 calorific value, 344 classification of, 340, 343 oombustion index, 345 combustion of, 344, 378 estimating consumption, 392, 455 heating of, 383 piping, 383 storage, 383
Oil burners, 382 atomizing, 382 boiler settings, 381 classification, 375, 382 oombustion adjustments, 379 combustion efficiency, 380 oombustion process, 378 commercial, 382 controls, 906 domestic, 375 furnace design, 381 gun type. 375 industrial, 382 measurement of efficiency of combustion, 380 mechanical draft, 375 operating requirements, 378 rotary type, 376, 382 vaporizing type, 377
One-pipe system, 494, 540, M5 gravity air-vent, 496 hot water, M5 steam, 6 supply riser, 6 unit heater connection, 494 vapor, 496
Opening, openings air supply noises, 955 stacks, 241 types of, 240 doors, 240 roof ventilators, 240 skylights, 240 vertical, 234 windows, 240
Operating rooms, 138 conditions, 139. reducing explosion hazard, 138 sterilization of air in,' 140
Orifice discharge, 75, 504, Ml flow, 75 formulas, 77, 1154 heating systems, 502 -
Orsat apparatus, 1162 Outdoor air, 113,685,1090,1093
Outlet, outlets air supply noises, 055 ceiling, 719 duct approaches, 723 location, 465, 475, 476, 720 performance, 715, 721 selection, 720 side outlets, 476
Outlet, outlets {continued) . sound absorbers, 955
types. 476, 704 wall outlets, 718 Outside temperature, 251, 279 Overhead distribution, 498, 1123 Overhead system, 498, 1123 Oxygen chambers, 146 tents, 146 therapy, 145 Ozone, 113
P
Panel heating, 571 application methods, 571 calculation principles, 675, 580 convection transfer, 576 design of panel, 5S0, 583 electric. 572, 968-970 embedded piping, 572 hot water, 571 installation, 584 output from surface, 575, 678 piping, 583 radiation transfer, 575 starting system, 573 steam, 671 * warm air, 490, 574
Panel radiator, 6 Particle size chart, 153 Perfect gas relationships, 27 Perforated ceilings, 720 Perforated outlets, 711, 720 Permeability, 209,213 Permeance, 209, 212, 213 pH value, 409, 987, 994 #. Physical impurities in air, 113
Physiological principles. 111 acclimatization, 116 comfort chart, 126 effective temperature, 122 high temperature hazards, 117 thermal interchanges, 113 upper limits of heat, 119
Pipe coils, 566, 591 heat emission, 565, 654 wall, 566
Pipe, piping, 623 application, 650 capacity, 506,508-613,538,1105 coatings, 1001 coil connections, 532 coil output, 565 cold water, 1105 commercial dimensions, 627 oonduits for, 674 connection to heating units, 520, 532 corrosion, 981, 993 covering, 655 design, not water system, M2 dimensions; 624 economical thickness insula tion, 667 . expansion, 644 fittings, 629. 633 fitting equivalent, 509, 537, 558, 1106, 1112 flexibility, 644 forced circulation, 542 friction loss, 536, 655, 1109 hangers, 648 heat losses, 653, 656 hot water heating systems, 542 hot water supply, 1122 inside dimensions, 624 _ insulation, 656, 677 insulation prevent freezing, 665 low temperature insulation,
663 materials, 623, 1001. one-pipe forced circulation,
M5 one-pipe gravity circulation,
M5 one-pipe vapor, 515
XIX
Pipe, piping (continued) overhead distribution, 499,
1123 properties, 624, 646 sizes, 507, M2
cooling systems, 1114
gas. 389 high pressure steam, 514-
516, 5M high temperature water, 553 hot water forced circulation,
545. 547 hot water gravity circula
tion, M5 indirect heating units, 518 low pressure, 509 one pipe riser, 510, 516 one pipe vapor, 515 orifice systems, 502 pressure drop, 507 sub-atmospheric systems,
517 tables for steam, 510-515 threading data, 628, 629 _ two-pipe forced circulation,
547 two-pipe gravity circula
tion, 546 two-pipe low pressure, 516 two-pipe riser, 610 two-pipe vapor systems, 516 vacuum systems, 517 water supply systems, 1105,
1122 steam distribution, 510, 675 steam heating systems, 510-
615 supports, 648 surface, 626 symbols for drawings, 17
tax, 403, 653 threading practice, 629 tunnels, 677 underground insulation, 667 unit heater connections, 494,
534,600 water supply, 1105
welding, 642 Pitot tubes, 84, 1152 Plate cell, 953 Plenum absorbers, 955 Plenum chambers* 6, 473 Pneumatic control systems, 896
Pollution of air, 151 Polyphase motors, 927 Ponds, 811 Potentiometer, 7, 1147 Power, 7 Precipitators, 785, 798 Precooling, 697 Premature infant nurseries, 140
Pressure absolute, 1 atmospheric, 1 changes in ducts, 731, 744
557, 1112 loss, water supply piping,
1108-1110 measurement, 1139
barometer, 1151 regulators, 518, 680, 902
static, 7
taps. 84 total, 7
vapor, 7 velocity. 7 Prime surface (see Heating Sur
face), 9 Propeller fan, 763, 771 Protective coatings, 1001
Psychrometer, 7,1158 Psychrometric chart, 51-53, 124
Pump, pumps condensate return, 522
high temperature, 556 mechanical circulators,
550
546,