Document GNRvnXqz1xaVQ3an989M57oq

Heating Ventilating Air Conditioning Guide 1956 Hot water heating systems {continued) one-pipe forced circulation, 540, 543, MS gravity circulation, 539, 542, 545 orifioe friction heads, 541 pipe sixes, 537-539, 555 _ forced circulation, 535-MO gravity circulation, 535-540 piping design, 542, 555 .pressure head, 535 relief valve, 552 reversed return system, MZ safety devices, 552 two-pipe forced, MO, M3, M7 gravity, 539, M6 soning, 552 Human body acclimatization, 118 adaptation. 113, US cold condition, 115 hot conditions, 115, 314 heat emission, 120,314 high temperature hazards, 117 metabolic rates, 113 odors, 113 temperature, 114 thermal interchanges, 113 sone of evaporative regulation, 115 Humid heat, 5 Humidification, 613, 805, 807 control, 490, 914 direct, 807 forced furnace systems, 490^ Humidifier, humidifiers air washer, 807 atomising, 809 high duty, 809 aeo-oontained, 810 spray, 809 unit, 809 Bumidistat, 5 ` Humidity, 5 absolute, 5 control, 688, 914, 1092 influence of, 122,141 measurement of, 1158 nurseries for premature in fants, 140 ratio. 5, 25 relative, 5, 25, 699 Hygrometers, 1159,1160 Hygroscopic materials, 1026 Hygrostat, 5, 901 I systems, 865 Impulse trap, 524-527 Tprn of water, 5 Induction units, 693 - high pressure types, 693 low pressure types, 692 Industrial air conditioning, 1015 calculations, 1031 ' , conditioning and drying, 1027 contaminant control,.lwl eontrol of chemical reac tions, 1027 dilution systems, 1032. general requirements, 1015, 1031 - humidities, 1015-1026, 1030 laboratories, 1030 local relief, 1033 .. machining tolerance.' 1030 moisturecontent and regain, 1026. ' polished surfaces, 1030. process, 1015 Industrial (continued) safety, 1031 . spot cooling, 1036 static electricity. 1030 temperatures. 1016-1026 exhaust systems, 1041 Infiltration causes, 227 . due to wind pressure, 228 heat losses, 266 latent. 268 ... sensible,267 measurement, 1158 temperature differences, 233 through outside doors, 229,231 through walla, 228 through windows, 229 . Inflammability, 162 Inside temperature, 258,259,276 Instruments, 1145 Insulation, 6, 653 _ economical pipe thickness, 667 Savity furnace duct, 463, 464 w temperature pipe, 663 pipe, 653 ' ` ... pipes to prevent freezing, 665 sound, 950 . _ thermal conductivity, 657 underground pipe, 667 Intermittently heated build ings, 270- Isobartc, 6 Isothermal; 6 J Jets, 703' expansion, 705 radial, 710 velocity, 705 Joints, duct, 755 Kata thermometer, 1157 Laboratories, 1030 Latent heat, 6, 268, 275 Ins*, 268 Laws of thermodynamics, < Leaders, 463 Leakage of air. 227 door, 229, 231, 232 * window, 229,230,311 light heat gun, 315 Lignite, 333 Liquid heat of. 5 Lithium bromide, 685 Lithium chloride, 685. Load cooling, 275. 689. design, 6,2o9 factor, 461 heating, 243,690 maximum, 6,403, 461 refrigeration, 275 M Machine vibration, 959 - Manometer, 6,1150 . Mrinn {see zitp heating, ^renti- latino,air conditioning) Mass, 6 Mbh, 538 Mean radiant temperature, 119, 579, 581, 912 : Meter* meters, 78, 683 area. 78) 85.683 condensate, 683 flow, 78, 85, 683 Meter, meters (continued) force, 78 ihead, 78,83,684 installation, 683 orifioe, 79, 11M selection, 684 velocity, 684 venturi, 1155 Metering, liquids, 78, 683 Mioromanometers, 1151 Micron, 6 Mist, 162 Moist air. 25 properties of, 25 saturation. 26 specific volume, 32 Moisture. 205, 1026. 1061 content, 1026, 1028, 1062 in building construction, zoo loss*per person, 122, 314, 892 movement in materials, zu permeability, 212 regain, 1026 transmission, 208 MMoonLo6fluorotrichlorometh. ane, 849,853 Motor, motors, 270,210, 923. alternating current, 927 capacitor type, 930 classification, 926 control, 934, 937 - - -. . control equipment for, 934 current limitation,.935 - limits, 924 drives, 924 electric, 923 enclosures, 939 glossary, 938 teat generated by, 270 hermetically enclosed, 932 - increment limitation, 935 multi-speed, 929, 936 polyphase, 927 rating. 936 . repulsion induction, 931. selection, 923 single phase, 930 _ speed characteristics, 926 speed classification, 939 speed ranges, 924 split phase, Ml squirrel cage, 927, 934 starting methods, 934. synchronous, 928,935 wound rotor, 928, 935 N Natural draft, 421 towers, 813 . . Natural ventilation, 235 Eineral rules, 241 eat removal, 237 Noise, noises, 941, 1133 absorptive material, 950 . air conditioning system, 942, 1133 air supply opening, 955 apparatus for measuring, .942 attenuation, 949 average in rooms, 946 control, 941 ' controlling vibration, 959 cross transmission between rooms, 958 design room level, 945 duct sound absorbers, 950,952 duet system attenuation, 949 fans, 946 general problem, 942 grille, 956 . intakes, 726 kinds of, 944 levels, 717, 943, 945 loudness, 941 Index to Technical Data Section Noise, noises (continued) measurement, 942 openings, 955 plate cells, 953 plenum absorption, 955 through building construe? tion, 958 transmitted through ducts, 944 typical sound level, 945 unit of measurement, 941 Nozzle flow, 75, 78 Nurseries for premature In fants, 140 air conditioning equipment, 141 o Odors. Ill, 113,147,156, 792 human body, 111 Oil Fuel, 340 analysis, 341 calorific value, 344 classification of, 340, 343 oombustion index, 345 combustion of, 344, 378 estimating consumption, 392, 455 heating of, 383 piping, 383 storage, 383 Oil burners, 382 atomizing, 382 boiler settings, 381 classification, 375, 382 oombustion adjustments, 379 combustion efficiency, 380 oombustion process, 378 commercial, 382 controls, 906 domestic, 375 furnace design, 381 gun type. 375 industrial, 382 measurement of efficiency of combustion, 380 mechanical draft, 375 operating requirements, 378 rotary type, 376, 382 vaporizing type, 377 One-pipe system, 494, 540, M5 gravity air-vent, 496 hot water, M5 steam, 6 supply riser, 6 unit heater connection, 494 vapor, 496 Opening, openings air supply noises, 955 stacks, 241 types of, 240 doors, 240 roof ventilators, 240 skylights, 240 vertical, 234 windows, 240 Operating rooms, 138 conditions, 139. reducing explosion hazard, 138 sterilization of air in,' 140 Orifice discharge, 75, 504, Ml flow, 75 formulas, 77, 1154 heating systems, 502 - Orsat apparatus, 1162 Outdoor air, 113,685,1090,1093 Outlet, outlets air supply noises, 055 ceiling, 719 duct approaches, 723 location, 465, 475, 476, 720 performance, 715, 721 selection, 720 side outlets, 476 Outlet, outlets {continued) . sound absorbers, 955 types. 476, 704 wall outlets, 718 Outside temperature, 251, 279 Overhead distribution, 498, 1123 Overhead system, 498, 1123 Oxygen chambers, 146 tents, 146 therapy, 145 Ozone, 113 P Panel heating, 571 application methods, 571 calculation principles, 675, 580 convection transfer, 576 design of panel, 5S0, 583 electric. 572, 968-970 embedded piping, 572 hot water, 571 installation, 584 output from surface, 575, 678 piping, 583 radiation transfer, 575 starting system, 573 steam, 671 * warm air, 490, 574 Panel radiator, 6 Particle size chart, 153 Perfect gas relationships, 27 Perforated ceilings, 720 Perforated outlets, 711, 720 Permeability, 209,213 Permeance, 209, 212, 213 pH value, 409, 987, 994 #. Physical impurities in air, 113 Physiological principles. 111 acclimatization, 116 comfort chart, 126 effective temperature, 122 high temperature hazards, 117 thermal interchanges, 113 upper limits of heat, 119 Pipe coils, 566, 591 heat emission, 565, 654 wall, 566 Pipe, piping, 623 application, 650 capacity, 506,508-613,538,1105 coatings, 1001 coil connections, 532 coil output, 565 cold water, 1105 commercial dimensions, 627 oonduits for, 674 connection to heating units, 520, 532 corrosion, 981, 993 covering, 655 design, not water system, M2 dimensions; 624 economical thickness insula tion, 667 . expansion, 644 fittings, 629. 633 fitting equivalent, 509, 537, 558, 1106, 1112 flexibility, 644 forced circulation, 542 friction loss, 536, 655, 1109 hangers, 648 heat losses, 653, 656 hot water heating systems, 542 hot water supply, 1122 inside dimensions, 624 _ insulation, 656, 677 insulation prevent freezing, 665 low temperature insulation, 663 materials, 623, 1001. one-pipe forced circulation, M5 one-pipe gravity circulation, M5 one-pipe vapor, 515 XIX Pipe, piping (continued) overhead distribution, 499, 1123 properties, 624, 646 sizes, 507, M2 cooling systems, 1114 gas. 389 high pressure steam, 514- 516, 5M high temperature water, 553 hot water forced circulation, 545. 547 hot water gravity circula tion, M5 indirect heating units, 518 low pressure, 509 one pipe riser, 510, 516 one pipe vapor, 515 orifice systems, 502 pressure drop, 507 sub-atmospheric systems, 517 tables for steam, 510-515 threading data, 628, 629 _ two-pipe forced circulation, 547 two-pipe gravity circula tion, 546 two-pipe low pressure, 516 two-pipe riser, 610 two-pipe vapor systems, 516 vacuum systems, 517 water supply systems, 1105, 1122 steam distribution, 510, 675 steam heating systems, 510- 615 supports, 648 surface, 626 symbols for drawings, 17 tax, 403, 653 threading practice, 629 tunnels, 677 underground insulation, 667 unit heater connections, 494, 534,600 water supply, 1105 welding, 642 Pitot tubes, 84, 1152 Plate cell, 953 Plenum absorbers, 955 Plenum chambers* 6, 473 Pneumatic control systems, 896 Pollution of air, 151 Polyphase motors, 927 Ponds, 811 Potentiometer, 7, 1147 Power, 7 Precipitators, 785, 798 Precooling, 697 Premature infant nurseries, 140 Pressure absolute, 1 atmospheric, 1 changes in ducts, 731, 744 557, 1112 loss, water supply piping, 1108-1110 measurement, 1139 barometer, 1151 regulators, 518, 680, 902 static, 7 taps. 84 total, 7 vapor, 7 velocity. 7 Prime surface (see Heating Sur face), 9 Propeller fan, 763, 771 Protective coatings, 1001 Psychrometer, 7,1158 Psychrometric chart, 51-53, 124 Pump, pumps condensate return, 522 high temperature, 556 mechanical circulators, 550 546,