INTEROFFICE MEMORANDUM
To:
From: Re:
Mr. A. K. McMillan
Date:
31 January 1974
R. R. Spiegelhalter
Copies:
Vinyl Chloride Vapor Levels in the PVC Plant - Preliminary Data
*
R. E. Jones E. A. Ray
fisAi.y/A 't*J
6jv-2>
Preliminary data have been obtained on the concentration levels of
vinyl chloride vapors in various areas of the PVC piant. The results are summarized in attached tables. The levels are reported for individual samples taken in some areas ahd are reported as a range in others. Sampling areas
are referenced to the schematics prepared by D. H. Francke where applicable.
Sampling Procedure
Samples were collected in a conventional gas bag (rubber balloon) by aspiration and carried to the laboratory for analysis. Composite samples, in a given plant area were obtained by walking through the area. The sampling probe was held at waist level. Approximately a liter of air sample was obtained over a period of 30-45 seconds.
Analytical Procednre
Air samples were analyzed by vapor phase chromatography using flame ionization detection and a column packed with a mixture of Poropak Q and Poropak S. A 0,5 cc sample was injected through a gas sampling valve. Standard calibrations were made by careful dilution of monomer vapors with air using a 100 ml syringe.
Accuracy and Precision
The precision of standards was shown to be 5%. Precision of sample repli cates was 5% and the accuracy * 10%.
Comments
The sampling procedure employed was an expedient. "Grab" samples of gases are not totally reliable. Development of a continuous sampling system is recommended. Analysis by VPC using a column to separate monomer from other hydrocarbons present should be continued.
RRSrfls Attachments : 3
R. R.
AP00001197
TABLE I COMPOSITE AIR SAMPLES
Polymerization Building
First Floor Second Floor Third Floor
Finishing Building
Levels 2 & 3 - Rolex Screen Area Level 4 - Product Collector Area
Bagging Room
First Floor - Bagging Machine Area Second Floor - Holding Bin Area
Warehouse
North Side of Building, Outside, Ground Level (below relief valve vent and outside the Nash recovery unit)
YC1 Levels Pound 2, 5, 13, 1530 ppm 5-15 ppm 5-50 ppm.
1 ppm 1-2 ppm
1-2 ppm 1 -2 ppm 2 ppm 10 - 180 ppm
31/1/74
AP00001198
TABLE II SPECIFIC EQUIPMENT AREA COMPOSITE SAMPLES
First Floor Reactor Building
Recovery Compressors Middle of Floor (Area 4)
Blend Tanks (West end of floor) (Area 6) Monomer Charge Pumps
(east end of floor - Area 6)
Blend Tank Area During Batch Drop
At Blend Tank Vent (outside) During Batch Drop
10 Feet From Blend Tank Vent During Batch Drop
VC1 Levels 1 - 2%
5-10 ppm 2-5 ppm
40 ppm 1340 ppm 79 ppm
31/1/74
t AP00001f99