Document GKeznn5pZyMz0bZpe6323Kwqn

Page 2128 1 Have you yourself done samples and measured 2 samples of how much asbestos fibers are in the air in 3 garage maintenance facilities? 4 A Yes. And, also,I sampled actually 5 facilities that produced these linings. When it gets 6 to the end, they have to grind them off as well and 7 measured concentrations there. You can generate some 8 very high dust concentrations. 9 Q Okay. Now, I would like to show you what is 10 table -- I would like to show you the next page which 11 is 120. 12 And did the article itself discuss the 13 significance of short fiber chrysotile? 14 A Yes. 15 Q And what did it say aboutthe short fiber 16 chrysotile, and what is the significance? 17 A The significance is this: The method that 18 we still use for counting fibers in the air is called 19 the membrane filter method. It started to be used in 20 about 1970 for regulation. 21 What it does is collects samples on a filter