Document G6wrnyLw7L5JoY8LmpEpwzyR4

-(/Vt>eK $ H.to 7 Tentative Bulletin MCS 1289 A Heat Transfer Fluid Candidate * "' ' ----- ` " "R o 400F "Nothing contained herein is to be construed is i recommendation to vso eny product in conflict witn any patent, MONSANTO MAKES NO WARRANTIES AS TO THE FITNESS OR MERCHANTABILITY OF ANY PRODUCT REFERRED TO, no guarantee of satisfactory results from reliance upon contained information or recommendations, and disclaims ell liability for any resulting toss or damage." Monsanto Industrial Chemical Co. Specialty Products 0586192 TOWOLDMONOQ37189 Typical Properties of MCS 1289 Composition Appearance Odor. Pour Point Plash Point . Fire Point Autoignition Temperature (AIT). Specific Gravity at 75P Density, lbs/gal. at 75P Viscosity, cs -65P 0P 100P 200P 300P noo'F 'Vapor Pressure 420P 572 P 6l0P Specific Oravity -6oP -20F 75P 200 F 300P 400P Specific Heat 212P Modified Ester Base Clear Yellow Liquid Paint -65F 4056F 438P 705P .919 7.63 6490 125 8.85 2.70 1.30 .85 10 mm Hg 180 mm Hg 590 mm Hg .976 .958 :6? .825 .785 approx. .56 BTU/#P 0586193 TOWOLDMONOQ37190 MCS 1289 is Intended for use as a heat transfer fluid where low ambient temperatures cause pumping problems with exist ing heat transfer fluids. The normal use range for MCS 1289 will be -25P to 400F bulk temperature maximum with an upper limit on film temperature of 450F. For long term use we suggest a maximum bulk temperature of 375F in a non-pressurlzed system; however, we do suggest a light inert gas blanket or cold seal for the expansion tank vent to preclude air contact at temperatures over 150F. MCS 1289 is not a fire resistant fluid. Although normal use temperature is below its flash and fire point we.suggest that suitable precautions be taken to minimize the risk of fire. Preliminary toxicity studies indicate that MCS 1289 should re quire no special handling precautions nor should it present an environmental hazard. Continuing studies are under way to pre pare more complete toxicity data. MCS 1289 has been tested in an N & C (nitrogen and corrosion) test for 168 hours at 450F with metal coupons to check metal compatibility. The tests indicate no abnormal metal attack, carbon formation or fluid property change. Heat transfer fluids are intended for indirect heating purposes only. Under no circumstances should heat transfer fluids con tact or in any way contaminate food, animal feed, food products, food packaging materials, pharmaceuticals or any food related items. Any contact may contaminate these items to the extent their destruction may be required. 058619*1 TOWOLDMONOQ37191