Document G6wqMzg0aMnyBG3jEM7vo5b0x
ratings
unit number
*roting -- horsepower -- MBtuh
-- steam per hour -- 21 2F ..
lb
firing rate -- No. 2 oil **.. ..
-- gas
gph MBtuh
heating surface..
. sq ft
furnace volume -- plain furnace
cu ft
-- corrugated furnace.. . . cu ft
safety valve capacity
lb stea m per hr
"Certified output. '"Based on 140,000 Btu oil
KGP-18
18 606 624 5.4 757
99 16 9
792
Designed in eight convenient sizes for high pressure steam or high temperature water above 250 F. 125 and 150 lb. working pressure, 18 to 92 hp.
This is the reliable Kewanee Scottie Jr. Series combined with the Gordon-Piatt TURBO-RING burner for oil, gas or gas-oil operation.
Exceptionally compact, electronic combustion safeguard, sequencing relays, motor starting relays, switches, lights and fuses are mounted in a control panel, wired to a convenient terminal strip.
Automatic fuel changeover, quiet forced-draft operation at certified ratings without high stacks are but a few of the unit's outstanding features.
The boiler and burner are shipped separately to the job site providing a definite advantage since delivery can be timed to suit
I construction stages of the building ... the boiler first for placement before walls or roof are completed ... the burner with its more sensitive parts after construction is finished. Matched connections of boiler and burner makes assembly quick and easy.
See Page 5 for burner details.
KGP-29
29 967 996 8.6 1208 158 21 4
1264
KGP-39
39 1 316 1 356 11.7 1645
215 29.6
1720
PAGE 1
KGP-45
45 1530 1577 13.6 1912
250 32.0
2000
KGP-59
59 1971 2031 17.5 2463
322 47.9
2576
KGP-65
65 2191 2258 19.5 2738
358 50.8
2864
KGP-78
78 2625 2705 23.4 3281
429
62.5 3432
KGP-92
92 . 3091 3185 27.5 3863
500
67 7 4000
28467
high pressure forced draft package units
light oil, gas or oil-gas combination
v. M&ssrH
dimensions (feet
unit number
A length overall... B -- width overall
................. .................
C -- boiler -- width-
..........................
D--
-- inside diameter..................
E--
-- length ...
.............
F -- lifting loop height . . . G -- steam supply height
. ..
H --smoke outlet height........................... J -- water line height.................................
K -- steam supply....................
L -- safety valve.....................................
N -- feed water, each side........................
O -- blow-off
..
P smoke outlet -- inside diameter. . .
R--
-- location..
S -- furnace height
........
T -- base -- length
...
U--
-- locotion..............
V--
-- width.
X -- burner front to boiler.
Y rear door clearance. .
AA -- tube replacement space -- front
BB --
-- rear
CC -- width DD -- width ..
...
KGP-18
8-10 4-6
4-0/j 3-6 7-1
5-4/a 4-1 Vi
5-6 4-3 2-3 1-8 4-7 Vi 2-8'/a 0-10 0-4'A
2-5 Vi 7-3`/a 0-1 3-0
1-4 1-9 3-3 3-5'/2 2-0
2-7'/, 1-10'/,
data
unit number
KGP-18
vent diameter
. in.
steam supply size blow-off size feed water size gas inlet...
....
in. .in. in. ,jn_
**outside surface to cover . .
. sa ft
approximate weight -- 125 lb wp.... lb
-- 150 lb wp. . lb
10 2 1
%
1
63 4200 4300
JUU lb American Standard Flange. "From of boiler and smokebox NOT included.
j KGP-S9 i KGP-39 i___________________
KGP-45
KGP-59
11-4 4-6
11-8 5-0
! 12-9 I 5-0
! 13-6 ' 5-6
: 4-o'/a 3-6
4-6'/] 4-0
4-6 Vi 4-0
T"
5-0'/,
9-7
! 10-1
1 11-2
! 11-11'/,
5-4 Vl 4-11 Vi
5-6 4-3
2-9 1-8 6-7
5-10'/,
5-10'/,
6-5
5-51*
5-5'/,
6-0
5-11 1*
> 5-11'/,
6-5`/i
4-7'/i
4-71* `
5-0ft
2-11
2-11
v 3-0
1-8 1-8 3-6
6-1 IVj
8-0/a
6-1
2-8'/i
3-0l/j
3-0/a
3-4/i
0-10 i 0-4'/j
1-1 ` 1-1 0-5 0-5
1-2 0-5 Vi
2-5 Vi 9-9'/i 0-1 3-0
2-6/a 9-6`/j 1-3 3-6
2-6/a 10-10
1-3 3-6
2-10 11-4
1-6 Vi 4-0
1-4 1-9
3-3 5-11
4-5 Vi
1-4 1-7
3-8 5-9'/a 4-2
1-4 1-7
3-8 6-10 Vi
5-3
1-4 1-6/a 4-1 7-2 5-3!/*
2-7'/, 1-10'/,
2-10/a 2-1 Vi
2-10/a 2-1 Vi
3-11* 2-4'/,
KGP-29
10 2 1 % 1 Va
5160 5260
KGP-39
13 2 1 %
I'/i
6380 6430
KGP-45 13 2 1
Va V/i
7130 7180
KGP-59 14 3 1 Va
Va
2
9280 9380
! KGP-65
14-7 I 5-6 I 5-01* i 4-6 1 12-101*
6-5 6-0 | 6-5*4 ! 5-oy* 3-6 i 3-6 7-4'/a 3-4 Vi V2 : 0-5Vi 2-10 12-3 1-6/a 4-0 1-4 1-8/a 4-1 8-1 6-2/a 3-1/2 2-4'/a
KGP-65
14 3 1 Va
Va
2 158 9820 9970
KGP-78
13-3'^ 6-1 5-5 5-0
6-10 7-0 7-1 }A 5-7`/i 3-1 4-3 6-6 4-0 1-4
3-1 Vi 10-8
1-6 5-0 1-6
j KGP-92
1 14-6
; 5-5 f 5-0
6-10 7-0 7-i
----------- -- I 3-7
4-4 7-1
1-4
3-1'/, 11-10
1-6V*
1-6
6-11 3-5
8-11* 3-5
KGP-78
KGP-92
16
4* 4*
22
1 Va 1'/ 2 2/a
178 197
12050
12780
19Q*iO
---------------------------- --
Standard equipment -- Boilers mounted on steel skids, gas-tight front steel smoke! with insulated cast iron gasketed flue doors Factory installed rear combust chamber Hinged rear combustion chamber door with pyrex observation port KkjP-18 thru KGP-65. rear cover plate with access panel and pyrex observat port on KGP-78 and KGP-92 Spinner blades, quadrant lock damper boiler lift loops, and flue cleaner w.th handle. Manhole on KGP-59 thru KGP-92 Nc Refractory filled burner mounting pfate furnished by burner manufacturer.
Copyright 1 958. American Radiator & Standard Somlary Corporation, Kewonee Boiler Division
Standard tfeam trimmings -- Safety valve(s); steam oage and cock; combination
water column, pump control and low water cut-off with wheel operated gage and
try cock assembly, blow-off valves,- globe and check volves for boiler feed line-
injector,- iron piping and fittings attaching trimmings to boiler.
'
Standard watef trimmings - Water relief vaive(s), low water cut-off, blow-off valves, iron piping and fittings attaching trimmings to boiler.
Standard eauipment subject to change without notice.
28468
PAGE 2
low pressure forced draft package units
light oil, gas or oil-gas combination
606,000 - 3,091,000 Btuh 15 lb (team 30 lb water 250 F maximum
The perfectly matched combination of Kcwanee Scottie Jr. and Gordon-Piatt TURBO-RING burner provides low pressure steam or hot water for heating at its automatic best. Large capacities are packed into low, trim units which fit easily into today's compact buildings. Features include electronic combustion safeguard, sequencing relays, mocor starting relays, switches, lights and fuses mounted in control panel and wired to convenient terminal strip. Fuel changeover is automatic, forced-draft operation is quiet and eliminates need for high stack. Rapid, easy access is provided to all parts of the boiler for inspection and maintenance. The cast iron flue doors open quickly by releasing simple locking clamps, steel skids require no special setting. Boiler and burner is shipped separately so that boiler can be delivered early in construction -- burner later, when it can be fully protected against weather, accident or theft.
unit number
rating -- steam.................
. sq ft
-- water
..
iq ft
-- MBtuh.................. -- steam per hour -- 212F... . ... lb
firing rate -- No. 2 oil**... -- gas
gph . . MBtuh
heating surface............
........ sq ft
furnace volume- -
. cu ft
safety valve capacity . .
lb steam per hr
"Certified output. ""Bosed on 140,000 Btu oil.
KGP-18
2520 4040
606 624 5.4 757
99 16.5 606
KGP-29
4030 6450
967 996 8.6 1208
158 21.7 967
KGP-39
5480 8770 1316 1356 11.7 1645
215 29.9 1316
PAGE 3
KGP-45
6370 10200
1530 1577 13.6 1912
250 32.7 1530
KGP-59
8210 13140
1971 2031 17.5 2463
322 52.5 1969
KGP-65
9130 14610
2191 2258 19.5 2738
358 56.0 2188
KGP-78
10940 17500
2625 2705 23.4 3281
429 64.8 2625
KGP-9t
12880 20610
3091 3185 27.5 3863
500 70.6 3060
28469
low pressure forced draft package units light oil, gas or oil-gas combination
NOTE: When selecting Package Unit, specify: (a) Unit Number, (b) Operating Pressure, (c) Type (steam or hot water), (d) Humor Model desired (oil, 90s or oil-gas combination), (e) Gas (type ana pressure available) consult local utility.
dimensions lfeet--inches)
unit number
A -- length overall...................................... B -- width overall.......................................
C -- boiler -- width....................................
D--
-- inside diameter...................
C--
-- length .................................
F -- lifting loop height.............................. Q -- steam supply height.......................... H -- smoke outlet height--................... J -- water line height...............................
K -- steam supply....................................... L ~ safety valve......................................... M -- return, each side................................ N -- feed water, each side........................ O -- drain.....................................................
P smoke outlet -- inside diameter... .
R--
--location...................
S -- furnace height.....................................
T -- base -- length.....................................
U *--
--location..................................
V--
--width.......................................
W -- floor to boiler.................................. X -- burner front to boiler........................
Y -- rear door cleamace............................
AA -- tube replacement space -- front..
BB --
-- rear. .
CC -- width.................................................. DD -- width.................................................
KGP-11
8-6 4-8 4-0% 3-6 6-1054 5-4)4 4-1154 5-6 4-254 2-3 1-8 3-6 %
2-8 % 0-10
0-354 2-5% 7-314 0-7 3-0 1-4 1-7% 3-3 3-3 1-10
2-9)4 1-1054
data
unit number
KGP-18
vent diameter.....................................
steam supply size..............................
return size (two).................................
drain size..............................
..
feed water size..................................
got inlet............
.....................
`outside surface to cover................
approximate weight..........................
. in.
in. .. in.
in. . .in. .. in.
sq ft
..lb
10 4 4 154
1 61
3450
*150 lb American Standard Flange. **Front of boiler and smokebox NOT included.
KGP-29
11-0 4-8 4-0% 3-6 9-4)4 5-4)4
4-11)4 5-6 4-254 2-9 1-8 3-8%
2-8% 0-10
0-3)4 2-5% 9-9% 0-7 3-0 1-4 1*7% 3-3 5-9 4-3)4 2-954 1-1054
KGP-29
10 4 4 154
154 88
4060
KGP-39
11-4 5-2 4-6% 4-0
9-1054 5-10% 5-10 5-11 %
4-7 2-11
1-8 4-3%
3-0% 1-1 0-4 2-6% 9-6% 0-11 3-6 1-4 1-5% 3-8 5-7 4-0 3-0)4 2-154
KGp-39
13 6* 4 154
154 105 5530
KGP-45
12-5 5-2 4-6% 4-0
10-1154 5-10% 5-10 5-11% 4-7 2-11 1-8 4-3%
3-0% 1-1 0-4 2-6% 10-10 0-11 3-6 1-4 1*5% 3-8 6-8 5-1 3-054 2-154
KGP-45
13 6* 4 154
154 119 6130
KGP-59
13-3% 5-9
4-11 4-6
11-854 6-554 6-7 6-854 5-314 3-0 5-4 4-4 2-4 4-0 1-2 0-414 3-1 10-10 1-6 4-6 1-7 1-7
7-2
3-454 2-454
KGP-59
14 6* 4 154 1% 2 165
8030
KOf ia THRU KGP-4J ILLUSTRATED
MANHOLE ON KGP-59 THRU KGP-92. 'OPTIONAL
KGP-65
14-4% 5-9
4-11 4-6
12-754 6-554 6-7 6-814 5-314 3-6 5-9 4-4 2-9 4-0
0-4)4 3-1 11-9 1-6 4-6 1-7 1-9
8-1
3-454 2-454
KGP-78
13-3% 6-3 5-5
11-7 6-10
7-0 7-1% 5-8 3-1 5-2 4-4 2-2 4-0
0-454 3-1% 10-8 1-6 5-0 1-6 1-8
6-11
3-7 2-8
.KGP-92
14-6 6-3 5-5
12-10 6-10
7-0 7-1% 5-8 3-7 5-10 4-4 2-9% 4-0
0-4% 3-1 % 11-10 1-6% 5-0 1-6 1-8
8-1 /,
3-7 2-8
KGP-65
14 6*
1% 1% 2 180 8870
KGP-78 16
1 !4 2 180 9500
KGP-92 16
1% 2% 200 10330
Standard equipment -- Boilers mounted on steel skid*) gas-tight Front steel smokebox with insulated cast iron gasketed flue doors. Factory installed rear combustion chamber. Hinged rear combustion chamber door with pyrex observation port,
KGP-18 thru KGP-4S; rear cover plate with access panel and pyrex observation port, KGP-59 thru KGP-92. Spinner blades. Quadrant lock damper. Flue cleaner with handle. Manhole KGP-59 thru KGP-92. Note: Refractory filled burner mount ing plate furnished by burner manufacturer.
Standard steam trimmings -- Safety valve(s)j steam gage and cock) combination water column, water gage and low water cut-off. Angle drain valve. Iron piping and fittings attaching these trimmings to boiler.
Standard water trimmings -- Water relief volve(s), pressure gage, thermometer, low water cut-off, iron piping and fittings attaching these trimmings to boiler. Angle drain valve.
Standard equipment subject to change without notice.
28470
PAGE 4
boiler burner
unit
KGP-18 KGP-29 KGP-39 KGP-45 KGP-59 KGP-65 KGP-78 KGP-92
input
MBtuh gas
gph oil
757 1208 1645 1912 2463 2738 3281 3863
5.4 8.6 11.7 13.6 17.5 19.5 23.4 27.5
blower motor
hp volt
% 115 V* 115 '/> 115 '/l 115 'h 115/230 Vi 115/230 % 115/230 % 115/230
gas control
pipe size
1*
1V4* 1 Vi' 1V4* 2' 2' 2'
!'
burner no.
gas--FGR oil gas--PGRO
oil --FRO
1-10-02 1-12-02 1-15-03 1-15-03 1-20-05 2-20-05 2-20-07 2-25-07
control system assembly
description of control systems available
B on-off control of both gas and oil
C on-off control of both gas and oil, pre and post purge fan operation
0 pre and post purge fan operation, modulating control of gas (055G), hi-low-off control of oil
E pre and post purge fan operation, modulating control of gas (M904E motor and butterfly valve), hi-low-off control of oil with low fire oil start.
Note: Control size based on 6' W.C. gas pressure at inlet of controls.
when selecting, specify:
1. boiler-burner unit size 2. operating pressure 3 type (steam or water) 4. type fuel desired (gas) (gas-oil) (oil-future gas) 5. control system desired 6 current characteristics 7. additional equipment if desired a, manual reset safety valve
b. thermostat
standard equipment -- burner
burner number
blower motor and f.d. fan ....................................
front plate with refractory ..................................
control panel, switches & sig Its.................
electronic flame safety control..............................
gas mqnifold with brass orifices..........................
air flow safety switch............................................
inlet air louver...........................
.....................
primary air adjustment...................
....
pressure or temperature limit control.....................
pressure or temperature operating control...........
motor relay or magnetic starter..
...
diaphrogm gas valve -
...
manual gas shut-off valve ..................................
gas pressure regulator..............................................
pilot cock and tubing..............
...................
pilot solenoid valve...............................................
pilot gas pressure regulator.
...................
safety pilot burner
..........................
6000V ignition transformer....................................
gas pressure gage..
...................
fuel transfer switch
.....................
oil pump set
...........................................
oil solenoid volve(s)..
...................
10,000V ignition transformer.........................
oil phofocell oil filter and gage
................................ ..............................
gas*
FGR
X X X X X X X X X X X
X X X X X X X X X
oil-gas FGRO
X X X X X X X
X X X
X X X X X X X X
X
"Standard controls furnished for natural gas at 6r pressure. Controls available for other types of gas and other gas pressures.
oil FRO
X X X X X X X X X X
X X X X X
c. low water cutoff & feeder
28471
PAGE 5
forced draft package units light oil, gas or oil-gas combination
sizes for IS, 125, 150 swp
simplex or duplex units
The simplex unit is illustrated. Du plex unit consists of two pumps and two motors mounted on a single chassis with the tank. Duplex units are often advisable for stand-by pur poses or with a battery of two boilers; each boiler supplied by a separate pump.
boiler feed units (dimensions -- inches)
unit KXB KXC KXE KXF
A B c DE FGH
30 38 Vi 30 34'/j 22
i% 8% 1%
37% 39 % 30 36% 59 Vi 3% 9% SVi
42 60 47% 55VS 33
3% 11% 3 Vi
46 78 63'/j 73% 36
4% 14
5
oJ K L N
QR
U VX Z
Vi 16
4 VS 19
1
3% 13% 1% 1% 2
%
Vi 18
6% 26% 1
3% 13% 1% 2
2
%
% 29% 7% 23
1% 9% 14% 1% 2% 2% 1
% 27 10% 28
1% 9
18% -- 3
3
1%
pump number
103-105, 028, 1022, 1023 141, 1128-1133
W
1 1 l!4
specifications and catalog numbers
unif number
boiler feed unit number
gpm -- max 195 0 F....
pump number...
molor size hp --- rpm
lank capacity
gal
shipping weight. lb
boiler feed unit number.
gpm -- max 195 F___
pump number..
motor sire hp--rpm
tank capacity
gal
shipping weight. lb
boiler feed unit number gpm -- max 195 F.... pump number motor sire hp -- rpm tank capacity . go) shipping weight. ib
1 5 swp .125 swp 1 50 swp
KGP-18
KXB-75 3.7 103
%-1750 20
200
KXB-73 3.5
1022-B 1 %-3500
20 270
KXB-74 3.5
1128 1%-3500
20 285
KGP-29
KXC-75 6.0 104
14-1750 35
230
KXC-69 6.2
1023 1`/j-3500
35 310
KXC-73 6.2
1130 2-3500
35 320
KGP-39
KXC-75 8.1 104
%-1750 35
230
KXC-89 6.8
1023 1 %-3500
35 310
KXC-73 6.8
1130 2-3500
35 320
KGP-45
KXE-20 9.3 105
%-1750 60
275
KXE-10 7.6
1130 2-3500
60 450
KXE-12 7.6
1131 3-3500
60 450
KGP-59
KXE-20 12.2 105
%-1750 60
275
KXE-11
9.0 1131 2-3500
60 450
KXE-12 9.0
1131 3-3500
60 450
KGP-65
KXE-24 13.5 028
Zj-1750 60
275
KXE-11 10.0 1131
2-3500 60
450
KXE-12 10.0 1131
3-3500 60
450
KGP-78
KXF-20 12.6 141
%-1750 100 550
KXF-11
10.5 1133 3-3500
100 6S0
KXF-11 10.5 1133
3-3500 100 650
KGP-92
KXF-20 12.6 141
%-t 750 100 550
KXF-11 12.6 1133
3-3500
650
KXF-21 12.6 1251
5-3500
100
750
FORM NO. 113 9
13M 12-58 GL
Ame rican andard
KEWANEE BOILER DIVISION
lOI FRANKLIN STREET. KEWANEE. ILLINOIS
PAGE 6
lifho in U S.A.
28472