Document G6nLzRE8JZLe7E51DEGn2Lyq7
16 _____________
, CfUPTER 2
1948 Guide
GRAPHICAL SYMBOLS FOR DRAWINGS6
Graphical Symbols for Drawings
Heating X. High Pressure Steam 2. Medium Pressure Steam 3. Low Pressure Steam 4. High Pressure Return. 5. Medium Pressure Return 6.. Low Pressure Return
.7. Boiler Blow Off 8. Condensate or Vacuum Pump Discharge 9. Feedwater Pump Discharge 10. Make Up Water 11. Air Relief Line 12. Fuel Oil Flow 13. Fuel Oil Return 14. Fuel Oil Tank Vent 15. Compressed Air 16. Hot Water Heating Supply 17. Hot Water Heating Return
Piping
------- o-
/
oo----
---------------- :---- FOF---------------------
' ;------------------------ A------------------------
i Air Conditioning
18. Refrigerant Discharge 19. Refrigerant Suction 20. Condenser Water Flow 21. Condenser Water Return 22. Circulating Chilled or Hot Water Flow 23. Circulating Chilled or Hot Water Return 24. Make Up Water 25. Humidification Line 26. Drain 27. Brine Supply 28. Brine Return
RDRS-CCR-
CH
-H-D-BBR-
Plumbing 29. Soil, Waste or Leader (Above Grade) 30. Soil, Waste or Leader (Below Grade)
31. Vent 32. Cold Water 33. Hot Water 34. Hot Water Return 35. Fire Line 36. Gas 37. Acid Waste 38. Drinking Water Flow 39. Drinking Water Return 40. VacuumCleaning 41. Compressed Air
%
-----f------------ :----- ------
----g-----------------------r--6--------
------------- -------------------------------------------- -- :---------------------------------
-- v------------------- v-----------:-------a---------------
Sprinklers
42. Main Supplies 43. Branch and Head 44. Drain
--------------- s---------------
----o
o-----
_s____________ s___
Graphical Symbols for Use on Drawings in Mechanical Engineering, Z32.2-1941 (American Standards Association).
Abbreviations and Symbols ,
17 .
Graphical Symbols for Drawings 45. Duct (1st Figure, Width; 2nd, Depth) 46. Direction of Flow 47. Inclined Drop in Respect to Air Flow 48. Inclined Rise in Respect to Air Flow 49. Supply Duct-Section . 50. Exhaust Duct Section 51. Recirculation Duct Section 62. Fresh Air Duct Section 53. Other Duct Sections 54. Register 55. Grille 56. Supply Outlet 57. Exhaust Inlet 68. Top Register or Grille 59. Center Register or Grille
60. Bottom Register or Grille 61. Top and Bottom Register or Grille 62. Ceiling Register or Grille 63. Louver Opening
64. Adjustable Plaque
'Ductwork
IXH---- 12x20 HEU*---- 12x20
-------- 12x20 1f^K------ 12x20
__ (Label) Kitchen Ext).
R G II--
TR,||^--
11 2Qx!2- 700cfm
I* TG 20x/2-700cfm h CR*20x12- 700cfm I1 CG 20*12- 700cfm |i BR? 20*12-- IQOcfm I1 B6 20x12-700cfm
. 11 TSBR 20 */2- ear. 700 cfm
I1 T&BG 20x/2-ea. 700 Cfm p--pi CR 20 x 12 -- 700 cfm
CG 20*12-700cfm I L ; 20 x 12 - 700cfm
_ pr j9-20*12-700cfm
11r--
L __j--------------- __________ P-20"<j>-700cfm