Document G6Yo0M3yBdNowQrBE2KKo9L4x
D. N. CO.
To 1 J. H. Walton AT 1586 KB
INTER-OFFICE MEMORANDUM
Copies to
D. R. Canham J. D. Cassidy P. J. Franklin
J. W. Gregg J. P. Hughes, M.D E. H. Schaper
August
1972
From AA. J
rommershausen
at 2675 OB
Subject
St. Helens - Industrial Hygiene Survey
On August 3, a visit was made to the St. Helens wallboard plant, to make an assessment of the asbestos handling and to update the previous noise survey.
The new Federal Asbestos Standard was discussed thoroughly with Jay and Jack, and suggestions were made on handling broken bags, cleaning up spills, disposing of empty bags, and the respirator program. According to Ted Baldwin of Permanente, bagged asbestos is now available in plastic encapsulated pallets. Besides preventing broken bags and spills, the plastic can be used for empty bag disposal. Jack has been advised and is looking into the matter for St. Helens.
It is anticipated that the plant will be using asbestos during the week of August 21, and I plan to sample for asbestos and evaluate the ventilation system during this time.
Doctor Stewart appears to be handling the plant medical problems satisfactorily. He alsocan do the asbestos examinations, including pulmonary function tests, whenever we work out the details later this year.
A visit was made to the hospital to meet Mr. Lung, who does the audiometric tests. Mr. Lung is exceptionally well qualified in audiometry, and also in pulmonary function testing and as an x-ray technician.
Noise levels at the plant are essentially unchanged from my initial survey in May 1971.
The following values were obtained on the new #4 line:
Re-trim Calender Tile machine Drying and pulling
At desk
88 dBA 92-98 dBA 100 dBA 98 dBA 98 dBA
The 2x8 sheeting machine gave values of 108 dBA. In addition, bursts of air from pistons or valves gave peaks over 110 dBA.
KG-0023
J. H. Walton
)
2
August 8, 1972
Noise from these sources can be easily and inexpensively controlled by the installation of noise silencers - e.g., Permahush Noise Silencers by: Bonded Products, Inc.
P.0. Box 263, Wrentham, MA 02093.
A copy of the literature is being sent to Jack. It should be a company policy to install silencers on all such equipment.
As you know, the D.O.L. and labor unions now are properly pushing control of noise and airborne contaminants, rather than the use of personal protective equipment. The plant has a fairly good ear protection plan underway, but the use of ear protection is now considered only as an "interim" solution. The St. Helens plant may possibly be particularly vulnerable, inasmuch as they are producers of high quality acoustical materials, have expertise in acoustics and noise control, and - as far as I could see - are not using any of their products to reduce the relatively hazardous noise levels in their own plant.
A number of suggestions were made to plant personnel on possible ways to reduce the noise levels at several locations, using their own products and other materials such as lead-lined vinyl cloth.
The plant' has a long way to go on noise control. A systematic
approach should be initiated immediately.
-
I will be glad to assist in any way I can.
gb