640 CHAPTER 23 . ,1958 Guide Table 9. Viscosity Effect on Centrifugal Pump Characteristics Kinematic Viscosity ssu* - Pump Head: 0 to 30 50 100 200 1.00 1.00 0.98 0.96 300 0.95 400 0.93 500 0.92 600 0.91 . 700 800 900 1000 ' 0.90 0.89 : 0.88 0.87 * SSTJ -- Saybolt Seconds-- Universal. Cohbection Factors Pump Capacity 1.00 1.00 1.00 0.98 0.97 0.96 0.96 0.95 0.94 : 0.94 0.93 0.92 . . . Pump Efficiency ! 1.00 0.94 0.88 0.79 0.73 0.68 0.65 0.62 0.59 .0.57 0.55 0.53 . 2. Keep pipe near surface--about 2 in. cover. 3. Use reinforcing steel designed for thermal stress if high structural loads are expected (such as on highways). Testing After installation and before pouring concrete, all piping should be tested to about 100 psi. This pressure should be maintained until all welds and connections have been checked for leaks. If an oil is used as an anti freeze, the test should be performed with air or some gas (only 50 psi re quired with an air test) but rioi with water. .The. danger of using water- is that the pipe may not be thoroughly dried when the oil is introduced^ The water will tend to collect, and when the temperature falls below 32 -FU the collected water may freeze and cause damage. ' u Draining Proper drainage is necessary for both the slab surface and the coil. The slab must be sloped so that the water from the melted snow can..; run off. Puddles are objectionable on sidewalks-or drives. They causey splashing, and they retard heat flow from the embedded,pipes. ; The pipes must be placed.so that they may be drained. .If the anti-,i freeze becomes corrosive it must be. drained.;.-It is not good practice,\toj rely entirely on blowing of air through the system. , Drifting Snow It is quite likely that some drifting will occur on every system that`isjj adjacent to a wall or vertical surface. The designer should try to antick-; pate this condition and add extra piping in these areas. If possible, coilsf should be added in the vertical surface. Another expedient is to carry . the drainage to the area expected to be drifted! The drainage will tend y to wash away some of the snow. tod Design Example Example 4' Design a snow-melting system for an area of, 10,000 sq ft in Pittsburgh:.; Pa. using a free area ratio of 0.5. Assume an air temperature of 10 F and a wind y, velocity of 10 mph. Use an oil antifreeze,solution. Panel Heating 641 Pipe Size ' 'A: %. i \'A IK 2 2K 3 3K 4 5 6 Table.10. Correction Factors for Pipe Size : (For Laminar Flow, Wr0 < 2000) Inside Diameter inches Feet Di* . 5.84 X10"*1 " 7>i` Ft* (See Figure 20) . 6.622 .: 0.824 1.049 ,1.380 1.610 2.067 2.469 3.068 3.548 4.026 5.047 6.065 x 0.0518 0.0687 . 0.0874 0.115 0.134 0.172 0.206 0.256 0.296 ' 0.335 0.421 0.505 7.18 X 10-" 2.23 X 10"s 5.84 X 10-* 1.75 X 10~4 3.26 X 10-4 8.75 X 10"4 1.81 X 1(F3 4.30 X 10-' 7.68 X 10~3 1.26 X10-" 3.14 X 10- 6.50 X 10-* 8.13 2.62 1.00 . 0.334 0.179 0.0667 0.0322 0.0136 0.00760 0.00462 0.00186 0.000898 - Solution : From Table 5 select a snowfall rate of 0.08. From Table 6 find the re quired heat output of top of slab, as qa = 168 for Ra -- 1, and ga -- 64 for R\ =0. Then for R& = 0.5 use qa = 116 because 0.5(168--61) + 64 = 116. From Equation 12 t,, = 6.5g,, + t, = (0.5 X 116) + 33 = 91 F. Assume that back and edge losses are 40 percent. Then the total heat require ment on heat exchanger is A^t = 10,000 X 1.40 X 116 = 1,624,000 Btuh. From Equation 25 Avqt- _ 1,624,000 160wmin - 160 X 60.5 X 6.431 390 gpm (Interpolating from Table 7, wm = 60.5 and cm.= 0.431 for <m = 91 F.) . Since a temperature drop of 20 deg was used, the fluid must enter the slab at 101 F and leave at 81 F. Assume that the coil circuit of longest equivalent length is 300 ft and has.a flow of 12 gpm and the pipe is.1-in. IPS. From Table 1, Chapter 26, the I.D. = 1.049 *n. -- 0.0875 ft and the I. D. section area = 0.864 sq in. = 0.00600 sq ft, hence for 12 gpm, the flow is 0.0268 cu ft per sec and the velocity = = 4.47 fpsi 0.00600 Interpolating from Table 7, the kinematic viscosity is 4.92 X 10-6 ft1 per sec. (An accurate interpolation requires the use of ASTM Standard Viscosity chart B.) Hence the Reynolds number =----- = 4.92 X 10-` n nm 7om * I Chapter 4, using a roughness factor of e = 0.00015, whence e/D = ` - 72, the friction factor / is found to be 0.0355. Substituting in Equation 23 : L V> ' 300 4.471 hi = / X D X -- 2g - 0.0355 X 0.0875 X 64.3 = 37.9 ft of fluid = 15.9 psia. must j ?.umP must deliver 390 gpm against a 15.9 psia head. The heat.exchanger Stiire 6f Htuh with an inlet tenmrpe__ra__tu__re__o_f__8_1_F__a_n_d__a_n__o_u_t_le__t_t_e_m_pera- nin:n,, / . F- (Actually an allowance should be made for temperature drop in the i>'' Th*t>etWeen s'a5 and the heat exchanger.) in Chant^o3*011 i'311*5 should be designed in accordance with the procedure outlined ; pter 21i Hot Water Heating Systems. The amount of expansion should be