3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Final Report Analysis of PFOA, PFBS, PFHS, and PFOS in Aqueous Samples from 3M Decatur, Alabama: Groundwater Treatment Plant GAC System December 2013 Laboratory Request Number: ISO13-07-11 Method Requirement: 3M Method ETS-8-044.1 Report Date - Date of Last Signature Testing Laboratory 3M EHS&S Operations 3M Environmental Laboratory Building 260-5N-17 Maplewood, MN 55144-1000 Requester Gary Hohenstein 3M Building 224-5W-03 Saint Paul, MN 55144-1000 Phone: (651) 737-3570 The testing reported herein meet the requirements of ANSI/ISO/IEC 17025:2005 "General Requirements for the Competence of Testing and Calibration Laboratories", in accordance with the A2LA Testing Certificate # 2052.01. Additionally, the laboratory's quality system has been audited and was determined to be in conformance with the EPA GLPs (40 CFR 792) by an independent A2LA assessment. PAGE 1 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 3M Environmental Laboratory 3M Environmental Laboratory Technical Director: William K. Reagen, Ph.D. 3M Principal Analytical Investigator: Susan Wolf Report Author: Chelsie Grochow Analytical Report ISO13-07-11 3M Decatur Groundwater Treatment Plant System; December 2013 Sampling Report Date: Date of Last Signature 1 Introduction/Summary The 3M Environmental Laboratory analyzed water samples from the groundwater treatment plant GAC system at the 3M Decatur, AL facility. Water samples were collected by Weston Solutions personnel on December 13, 2013. Samples were returned to the 3M Environmental Laboratory for analysis of Perfluorooctanoate (PFOA), Perfluorobutane sulfonate (PFBS), Perfluorohexane sulfonate (PFHS), Perfluorooctane sulfonate (PFOS) under laboratory project number ISO13-07-11. Analysis of the samples was completed as specified under 3M Environmental Laboratory General Project Outline (GPO) number GPO11-1006. The 3M Environmental Laboratory provided sample containers for seven sampling locations; ACI, ACM2, ACE, WW8R, WW9R, WW10R, and WW11R. The sample set consisted of a field sample, field sample duplicate and a field matrix spike. Each empty container was marked with a "fill to here" line that corresponded to a final volume of 200 mL. Containers reserved for field matrix spikes were fortified with an appropriate matrix spike solution containing all analytes prior to being sent to the field for sample collection. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with internal standards and surrogates prior to being sent to the field for sample collection. Due to an error during the bottle prep, internal standard was not added to the ACE FMS sample prior to analysis. Samples were prepared and analyzed by method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Select internal standards were used to aid in the data quality objectives. Table 1 summarizes the sample results using the analytical method identified above. All results for quality control samples prepared and analyzed with the samples will be reported and discussed elsewhere in this report. The testing reported herein meet the requirements of ANSI/ISO/IEC 17025:2005 "General Requirements for the Competence of Testing and Calibration Laboratories", in accordance with the A2LA Testing Certificate # 2052.01. Additionally, the laboratory's quality system has been audited and was determined to be in conformance with the EPA GLPs (40 CFR 792) by an independent A2LA assessment. PAGE 2 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 1. Sample Results Summary 3M LIMS ID Sample Description ISO13-07-11-001 ISO13-07-11-002 ISO13-07-11-004 ISO13-07-11-005 ISO13-07-11-007 ISO13-07-11-008 ISO13-07-11-010 ISO13-07-11-011 ISO13-07-11-013 ISO13-07-11-014 ISO13-07-11-019 ISO13-07-11-020 ISO13-07-11-022 ISO13-07-11-023 DAL-GW-ACI; Sample DAL-GW-ACI; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-ACM2; Sample DAL-GW-ACM2; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-ACE; Sample DAL-GW-ACE; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-WW8R; Sample DAL-GW-WW8R; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-WW9R; Sample DAL-GW-WW9R; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-WW10R; Sample DAL-GW-WW10R; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-WW11R; Sample DAL-GW-WW11R; Sample Dup Average %RPD Sample/Sample Dup PFOA Concentration (ng/mL) 1840 1820 1830 (1) 1.1 0.0729 0.0775 0.0752 (2) 6.1 0.0728 0.0868 0.0798 (2) 18 2700 2730 2720 (1) 1.1 2670 2700 2690 (1) 1.1 1910 1870 1890 (1) 2.1 1050 1060 1060 (1) 0.94 PFBS Concentration (ng/mL) 1330 1360 1350 (1) 2.2 1430 1440 1440 (1) 0.69 0.0725 0.0806 0.0766 (2) 11 316 316 316 (1) 0.0 264 253 259 (1) 4.2 239 238 239 (1) 0.42 200 195 198 (1) 2.5 PFHS Concentration (ng/mL) 687 703 695 (1) 2.3 0.0587 0.0829 0.0708 (2) 34 (3) <0.0500 0.0648 0.0648 (2) NA 1260 1270 1270 (1) 0.79 1170 1160 1170 (1) 0.85 889 880 885 (1) 1.0 515 508 512 (1) 1.4 PFOS Concentration (ng/mL) 1960 1980 1970 (1) 1.0 0.531 0.606 0.569 (2) 13 0.0276 0.0330 0.0303 (2) 18 4070 4050 4060 (1) 0.49 4160 4210 4190 (1) 1.2 2950 2890 2920 (1) 2.1 1570 1560 1570 (1) 0.64 NA = Not Applicable (1) Reported results were prepared and analyzed by ETS-8-044.1 using external standard calibration. The analytical method uncertainties associated with the reported results are as follows: PFOA 17%, PFBS 17%, PFHS 16%, and PFOS 21 %. (2) Reported results were prepared and analyzed by ETS-8-044.1 using internal standard calibration. The analytical method uncertainties associated with the reported results are as follows: PFOA 17%, PFBS 14%, PFHS 23%, and PFOS 21 %. (3) Sample/sample duplicate RPD did not meet acceptance criteria of <20%. PAGE 3 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 2 Methods - Analytical and Preparatory 2.1 Methods Analysis was completed using 3M Environmental Laboratory Method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Table 2. Target Analytes Target Analytes Perfluorooctanoic Acid (C8 Acid) Perfluorobutanesulfonate (C4 Sulfonate ) Perfluorohexanesulfonate (C6 Sulfonate) Perfluorooctanesulfonate (C8 Sulfonate) Acronym PFOA PFBS PFHS PFOS Reference Material Structure Linear + Branched Linear Linear Linear + Branched 2.2 Sample Collection Samples were collected on December 13, 2013 in NalgeneTM (high-density polyethylene) bottles prepared at the 3M Environmental Laboratory. Prior to sample collection, bottles designated for field matrix spikes were spiked in the laboratory with a known volume of an appropriate matrix spiking solution containing PFOA, PFBS, PFHS, and PFOS. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with a mixture of mass-labeled internal standards at a nominal concentration of 1 ng/mL and a mixture of surrogate recovery standards at a nominal concentration of 0.1 ng/mL. Collected sample bottles were received by the laboratory at ambient conditions on December 18, 2013. 2.3 Sample Preparation All samples were diluted with methanol and analyzed for all analytes. Samples diluted 1:10 were prepared by removing a 1 mL aliquot of the well mixed sample and adding 8.9 mL of methanol and 0.1 mL of a surrogate spiking solution. The 1:100 dilutions were prepared by removing a 0.1 mL aliquot of the well mixed sample and adding 9.8 mL of methanol and 0.1 mL of a surrogate spiking solution. Prepared samples were analyzed by external standard calibration. Further dilution may have been applied by using a lower injection volume on the instrument. The ACE and ACM2 sample sets and the Trip Blank sample were prepared and analyzed for all analytes by transferring an aliquot of the well mixed sample into an autovial. Prepared samples were analyzed by internal standard calibration. Following sample analysis, it was discovered that the ACE FMS sample was not fortified with internal standard. Therefore, internal standard was added to an aliquot of the ACE FMS sample, and the ACE sample set was re-analyzed by internal standard calibration. During the preparation of the laboratory control samples for internal standard calibration, an aliquot of a separate internal standard spiking solution was added to the laboratory control samples (nominal concentration of 1 ng/mL). The sample bottles for ACE, ACM2, and Trip Blank were spiked with an internal standard mix at a nominal concentration of 1 ng/mL prior to being sent to the field for sample collection. The laboratory control samples were analyzed in the same manner as the samples. 2.4 Analysis All samples and quality control samples were analyzed for four target analytes using high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Pertinent instrument parameters, the liquid chromatography gradient program, and the specific mass transitions analyzed are described in the tables below. PAGE 4 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Due to the nature of the sample, the wide range of concentrations found in the sample, and the environmental occurrence of multiple isomers of the laboratory's analytes of interest, the software used for processing the analytical results is not able to consistently integrate the analytical peak, manual integration of the analytical peak is necessary. All manual integrations are performed following the procedures outlined in method ETS-12-010. The consistency of the laboratory's integration is ensured through the training of laboratory personnel, the peer review process required for all manual integrations, the review of manual integrations by the QAU, and where necessary the review of manual integrations by laboratory management. Table 3. Instrument Parameters. Instrument Name Analysis Dates Analytical Method Liquid Chromatograph Guard column Analytical column Injection Volume Mass Spectrometer Ion Source Polarity Software ETS Buster 1/8/14 - external standard calibration 1/9/14 and 1/10/14 - internal standard calibration ETS-8-044.1 Agilent 1100 Betasil C18 (4.6 mm X 100 mm), 5 x Betasil C18 (4.6 mm X 100 mm), 5 x 5 or 20 xL Applied Biosystems API 4000 Turbo Spray Negative Analyst 1.6.1 Table 4. Liquid Chromatography Gradient Program. Step Number 0 1 2 3 4 5 6 7 8 9 Total Time (min) 0.00 0.50 4.00 6.00 11.0 13.0 13.5 16.0 16.5 19.0 Flow Rate (uL/min) 750 750 750 750 750 750 750 750 750 750 Percent A (2 mM ammonium acetate) 90.0 90.0 70.0 70.0 20.0 20.0 10.0 10.0 90.0 90.0 Percent B (Methanol) 10.0 10.0 30.0 30.0 80.0 80.0 90.0 90.0 10.0 10.0 PAGE 5 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 5. Mass Transitions. Analyte Mass Transition Q1/Q3 Internal Standard (1) Mass Transition Q1/Q3 413/369 PFOA 413/219 [13C8]PFOA 421/376 413/169 PFBS 299/80 299/99 [18O2]PFBS 303/84 PFHS 399/99 399/80 [13Cs]PFHS 402/80 499/99 PFOS 499/80 [13C8]PFOS 507/80 499/130 [13C4]PFOA surrogate 417/372 [13C8]PFOA 421/376 [13C4]PFOS surrogate 503/80 [13C8]PFOS 507/80 Dwell time was 20 msec for each transition. The individual transitions were summed to produce a "total ion chromatogram" (TIC), which was used for quantitation. (1) Internal standards were used for the analysis on 1/9/14 and 1/10/14. 3 Data Analysis 3.1 Calibration External Standard Calibration Analysis on 1/8/14: Samples were analyzed against an external standard calibration curve. Calibration standards were prepared by spiking known amounts of the stock solution containing the target analytes into 90:10 methanol: Milli-Q laboratory water. A total of eleven spiked standards ranging from 0.02 ng/mL to 50 ng/mL (nominal) were analyzed. The standards also contained the surrogates at concentrations ranging from 0.02 ng/mL to 25 ng/mL nominal. A quadratic, 1/x weighted, calibration curve of the standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area counts and the resultant calibration curve confirmed accuracy of each curve point. Internal Standard Calibration Analysis on 1/9/14 and 1/10/14: Samples were analyzed against a matrix-matched stable isotope internal standard calibration curve. Calibration standards were prepared by spiking known amounts of stock solutions into laboratory prepared reagent water. The calibration standards contained an internal standard mix at a nominal concentration of 1 ng/mL. A total of thirteen calibration standards ranging from 0.025 ng/mL to 25 ng/mL (nominal) were analyzed with the prepared samples. O f these thirteen calibration standards, eleven contained the surrogates at concentrations ranging from 0.025 ng/mL to 10 ng/mL nominal. A quadratic, 1/x weighted, calibration curve of the ratio of the standard peak area counts over the internal standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area ratios and the resultant calibration curve confirmed accuracy of each curve point. For each calibration curve, the reference standards of PFOA and PFOS used to prepare the calibration standards consisted of both linear and branched isomers. Each curve point was quantitated using the overall calibration curve and reviewed for accuracy. Method calibration accuracy requirements of 10025% (10030% for the lowest curve point) were met for all analytes. The correlation coefficient r was greater than 0.995 for all analytes. PAGE 6 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 3.2 System Suitability A calibration standard was analyzed four times at the beginning of the analytical sequence to demonstrate overall system suitability. The acceptance criteria for system suitability samples is less than or equal to 5% relative standard deviation (RSD) for peak area/ratio and retention time criteria of less than or equal to 2% RSD. These criteria were met for all analytes. 3.3 Limit of Quantitation (LOQ) The LOQ as defined in method ETS-8-044.1 is the lowest non-zero calibration standard in the curve that meets linearity and accuracy requirements and for which the area counts are at least twice those of the appropriate blanks. The LOQs associated with the sample analysis are listed in Table 6. Table 6. LOQ Analyte LOQ, ng/mL 1/8/14 Analysis LOQ, ng/mL 1/9/14 Analysis PFOA 0.0192 (1) 0.0240 PFBS 0.0200 (1) 0.0250 PFHS 0.0200 (1) 0.0500 PFOS 0.0185 (1) 0.0232 (1) The dilution factor was not applied to the LOQ. LOQ, ng/mL 1/10/14 Analysis 0.0287 0.0250 0.0500 0.0232 3.4 Continuing Calibration During the course of the analytical sequence, several continuing calibration verification samples (CCVs) were analyzed to confirm that the instrument response and the initial calibration curve were still in control. The method acceptance criteria of 100% 25% was met for all analytes. 3.5 Blanks Two types of blanks were prepared and analyzed with the samples: method blanks/solvent blanks and field/trip blanks. Each blank result was reviewed and used to evaluate method performance to determine the LOQ for each analyte. 3.6 Lab Control Spikes (LCSs) Low, mid, and high lab control spikes were prepared for the target analytes and analyzed in triplicate, while only low and high lab control spikes were prepared for the surrogates. LCSs were prepared by spiking known amounts of the analytes into either 10 mL of laboratory-prepared matrix matched water or 1 mL of Milli-Q water to produce the desired concentration. When applicable, the LCSs were then diluted with methanol in the same manner as the samples. Method ETS-8-044.1 states that the average recovery of LCSs at each spiking level be within 80%-120% with a RSD <20%. All LCS samples met method accuracy criteria except for the mid level LCSs for PFHS (123%) on 1/9/14 and PFOS (121%) on 1/10/14. A method deviation is included with the raw data. All LCSs were used in the determination of the analytical method uncertainty in section 3.7. The following calculations were used to generate data in Table 7. Calculated Concentration * . LCS Percent Recovery -------------------------------------* 100% Spike Concentration LC S% RSD = standard deviation LC S replicates *ioo% average LC S recovery PAGE 7 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 7. Lab Control Spike Results. ETS-8-044.1 External Standard Calibration Analyzed 1/8/14 Lab ID PFOA (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140108-1 LCS-140108-2 LCS-140108-3 Average %RSD LCS-140108-4 LCS-140108-5 LCS-140108-6 Average %RSD 0.191 0.191 0.191 4.74 4.74 4.74 0.180 0.174 0.176 92.5% 1.7% 4.86 4.82 4.79 102% 0.57% 94.2 91.1 92.1 102 102 101 LCS-140108-7 LCS-140108-8 LCS-140108-9 Average %RSD 38.2 38.2 38.2 38.0 36.3 35.9 96.2% 3.1% 99.6 95.1 94.0 Spiked Concentration (ng/mL) PFOA surrogate Calculated Concentration (ng/mL) 0.199 0.199 0.199 0.222 0.219 0.217 110% 1.4% 4.94 5.16 4.94 5.07 4.94 5.07 104% 1.1% %Recovery 112 110 109 105 103 103 ETS-8-044.1 External Standard Calibration Analyzed 1/8/14 Lab ID Spiked Concentration (ng/mL) PFBS Calculated Concentration (ng/mL) LCS-140108-1 LCS-140108-2 LCS-140108-3 Average %RSD LCS-140108-4 LCS-140108-5 LCS-140108-6 Average %RSD LCS-140108-7 LCS-140108-8 LCS-140108-9 Average %RSD 0.199 0.199 0.199 4.95 4.95 4.95 39.8 39.8 39.8 0.204 0.201 0.195 100% 2.1% 5.04 5.03 4.94 101% 1.2% 41.9 41.3 40.1 103% 2.0% %Recovery 102 101 97.9 102 102 99.9 105 104 101 Spiked Concentration (ng/mL) 0.199 0.199 0.199 4.95 4.95 4.95 39.8 39.8 39.8 PFHS Calculated Concentration (ng/mL) 0.194 0.211 0.198 101% 4.3% 4.89 4.83 4.82 97.9% 0.72% >ULOQ >ULOQ >ULOQ NA %Recovery 97.7 106 99.4 98.7 97.6 97.4 NA NA NA >ULOQ = analyte concentration exceeded upper limit of quantitation NA = Not Applicable (1) LCS recovery did not meet acceptance criteria of 100 20%. PAGE 8 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 External Standard Calibration Analyzed 1/8/14 Lab ID PFOS (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140108-1 LCS-140108-2 LCS-140108-3 Average %RSD LCS-140108-4 LCS-140108-5 LCS-140108-6 Average %RSD 0.185 0.185 0.185 4.59 4.59 4.59 0.178 0.185 0.179 97.6% 2.0% 4.79 4.71 4.76 104% 0.56% 96.2 99.8 96.7 104 103 104 LCS-140108-7 LCS-140108-8 LCS-140108-9 Average %RSD 36.9 36.9 36.9 37.4 36.0 35.9 98.6% 2.1% 101 97.6 97.2 Spiked Concentration (ng/mL) PFOS surrogate Calculated Concentration (ng/mL) 0.190 0.190 0.190 0.226 0.220 0.236 120% 3.4% 4.73 5.38 4.73 5.40 4.73 5.35 114% 0.51% %Recovery 119 116 124 114 114 113 ETS-8-044.1 Internal Standard Calibration Analyzed 1/9/14 Lab ID PFOA (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140109-1 LCS-140109-2 LCS-140109-3 Average %RSD LCS-140109-4 LCS-140109-5 LCS-140109-6 Average %RSD 0.190 0.190 0.190 1.90 1.90 1.90 0.201 0.202 0.208 107% 2.2% 2.20 2.12 2.20 115% 2.0% 106 106 110 116 112 116 LCS-140109-7 LCS-140109-8 LCS-140109-9 Average %RSD 19.0 19.0 19.0 20.7 21.6 22.1 113% 3.2% 109 114 116 Spiked Concentration (ng/mL) PFOA surrogate Calculated Concentration (ng/mL) 0.198 0.198 0.198 0.230 0.244 0.235 119% 3.0% 1.98 2.40 1.98 2.31 1.98 2.35 119% 1.7% %Recovery 116 123 119 121 117 119 >ULOQ = analyte concentration exceeded upper limit of quantitation NA = Not Applicable (1) LCS recovery did not meet acceptance criteria of 100 20%. PAGE 9 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 Internal Standard Calibration Analyzed 1/9/14 Lab ID Spiked Concentration (ng/mL) PFBS Calculated Concentration (ng/mL) LCS-140109-1 LCS-140109-2 LCS-140109-3 Average %RSD LCS-140109-4 LCS-140109-5 LCS-140109-6 Average %RSD 0.198 0.198 0.198 1.98 1.98 1.98 0.210 0.212 0.229 110% 5.0% 2.15 2.08 2.08 106% 2.2% LCS-140109-7 LCS-140109-8 LCS-140109-9 Average %RSD 19.9 19.9 19.9 20.3 21.1 22.0 106% 4.3% %Recovery 106 107 116 109 105 105 102 106 111 Spiked Concentration (ng/mL) 0.198 0.198 0.198 1.98 1.98 1.98 19.9 19.9 19.9 PFHS Calculated Concentration (ng/mL) 0.179 0.235 0.211 105% 14% 2.47 2.40 2.41 123% 1.7% (1) 21.5 21.9 22.6 111% 2.8% %Recovery 90.4 119 106 125 121 122 108 110 114 ETS-8-044.1 Internal Standard Calibration Analyzed 1/9/14 Lab ID PFOS (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140109-1 LCS-140109-2 LCS-140109-3 Average %RSD LCS-140109-4 LCS-140109-5 LCS-140109-6 Average %RSD 0.184 0.184 0.184 1.84 1.84 1.84 0.224 0.216 0.219 119% 2.1% 2.11 2.09 2.18 116% 2.6% 122 117 119 115 113 119 LCS-140109-7 LCS-140109-8 LCS-140109-9 Average %RSD 18.4 18.4 18.4 20.6 20.5 21.1 113% 1.5% 112 112 115 Spiked Concentration (ng/mL) PFOS surrogate Calculated Concentration (ng/mL) 0.189 0.189 0.189 0.199 0.207 0.257 117% 14% 1.89 2.01 1.89 1.95 1.89 2.05 106% 2.4% %Recovery 105 109 136 106 103 108 >ULOQ = analyte concentration exceeded upper limit of quantitation NA = Not Applicable (1) LCS recovery did not meet acceptance criteria of 100 20%. PAGE 10 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 Internal Standard Calibration Analyzed 1/10/14 Lab ID PFOA (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140110-1 LCS-140110-2 LCS-140110-3 Average %RSD LCS-140110-4 LCS-140110-5 LCS-140110-6 Average %RSD 0.190 0.190 0.190 1.90 1.90 1.90 0.196 0.194 0.202 104% 2.0% 2.18 2.08 2.26 115% 3.9% 103 102 106 115 110 119 LCS-140110-7 LCS-140110-8 LCS-140110-9 Average %RSD 19.0 19.0 19.0 21.3 21.2 20.7 111% 1.6% 112 112 109 Spiked Concentration (ng/mL) PFOA surrogate Calculated Concentration (ng/mL) 0.198 0.198 0.198 0.237 0.217 0.249 118% 7.3% 1.98 2.35 1.98 2.23 1.98 2.27 115% 3.1% %Recovery 120 109 126 119 112 115 ETS-8-044.1 Internal Standard Calibration Analyzed 1/10/14 Lab ID Spiked Concentration (ng/mL) PFBS Calculated Concentration (ng/mL) LCS-140110-1 LCS-140110-2 LCS-140110-3 Average %RSD LCS-140110-4 LCS-140110-5 LCS-140110-6 Average %RSD 0.198 0.198 0.198 1.98 1.98 1.98 0.201 0.212 0.204 104% 2.9% 2.12 2.20 2.25 111% 3.2% LCS-140110-7 LCS-140110-8 LCS-140110-9 Average %RSD 19.9 19.9 19.9 20.8 20.6 20.1 103% 1.5% %Recovery 101 107 103 107 111 114 104 103 101 Spiked Concentration (ng/mL) 0.198 0.198 0.198 1.98 1.98 1.98 19.9 19.9 19.9 PFHS Calculated Concentration (ng/mL) 0.208 0.213 0.245 112% 9.3% 2.21 2.28 2.18 112% 2.2% 22.9 22.1 21.2 111% 3.6% %Recovery 105 107 124 112 115 110 115 111 107 >ULOQ = analyte concentration exceeded upper limit of quantitation NA = Not Applicable (1) LCS recovery did not meet acceptance criteria of 100 20%. PAGE 11 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 Internal Standard Calibration Analyzed 1/10/14 Lab ID PFOS (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140110-1 LCS-140110-2 LCS-140110-3 Average %RSD LCS-140110-4 LCS-140110-5 LCS-140110-6 Average %RSD 0.184 0.184 0.184 1.84 1.84 1.84 0.208 0.222 0.198 114% 6.2% 2.26 2.12 2.28 121% 4.1% (1) 113 121 107 123 115 124 LCS-140110-7 LCS-140110-8 LCS-140110-9 Average %RSD 18.4 18.4 18.4 21.1 20.8 19.1 110% 5.0% 114 113 104 Spiked Concentration (ng/mL) PFOS surrogate Calculated Concentration (ng/mL) 0.189 0.189 0.189 0.204 0.218 0.197 109% 5.1% 1.89 2.35 1.89 2.18 1.89 2.26 120% 4.2% %Recovery 108 115 104 125 115 120 >ULOQ = analyte concentration exceeded upper limit of quantitation NA = Not Applicable (1) LCS recovery did not meet acceptance criteria of 100 20%. 3.7 Analytical Method Uncertainty Analytical uncertainty is based on historical QC data that is control charted and used to evaluate method accuracy and precision. The method uncertainty is calculated following ETS-12-012.2. The standard deviation is calculated for the set of accuracy results (in %) obtained for the QC samples. The expanded uncertainty is calculated by multiplying the standard deviation by a factor of 2, which corresponds to a confidence level of 95%. The method uncertainty determined by ETS-12-012.2 was 21% for PFHS and 18% for PFOS, but the method uncertainty has been expanded based on the %bias of the non-compliant mid-level LCSs. Table 8. Analytical Method Uncertainty. Analyte PFOA PFBS PFHS PFOS PFOA PFBS PFHS PFOS Calibration Method External Standard External Standard External Standard External Standard Internal Standard Internal Standard Internal Standard Internal Standard Standard Deviation (%) 8.56 8.70 7.92 10.7 8.50 6.80 10.7 9.12 Method Uncertainty 17% 17% 16% 21% 17% 14% 23% 21% PAGE 12 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 3.8 Field Matrix Spikes (FMS) A field matrix spike was collected at each sampling point to verify that the analytical method is applicable to the collected matrix. Field matrix spikes are generated by adding a measured volume of field sample to a container spiked by the laboratory with the target analytes prior to shipping sample containers for sample collection. Field matrix spike recoveries within method acceptance criteria of 10030% confirm that "unknown" components in the sample matrix do not significantly interfere with the extraction and analysis of the analytes of interest. The standards used for the preparation of the field matrix spiking solutions contained reference materials comprised of both linear and branched isomers for PFOA and PFOS. Field matrix spikes are presented in section 4 of this report. FMS Recovery - (Sample Concentration of FMS - Average Concentration: Field Sample & Field Sample Dup.) * 1 0 0 % Spike Concentraton Table 9. Field Matrix Spike Concentrations. Location ACI ACM2 ACE WW8R, WW9R, WW10R, WW11R Trip Blank Description Field Matrix Spike Field Matrix Spike Field Matrix Spike Field Matrix Spike Low Field Matrix Spike High Field Matrix Spike Firial Concentr.tion (ng/mL PFOA PFBS PFHS PFOS 2480 4.96 4.96 2500 5.00 5.00 2510 5.00 5.00 2500 4.99 4.99 2480 2500 2510 2500 4.96 2480 5.00 2500 5.00 2510 4.99 2500 4 Data Summary and Discussion The tables below summarize the sample results and field matrix spike recoveries for the seven locations as well as the Trip Blank. Each table provides the average concentration and the relative percent difference (%RPD) of the sample and sample duplicate. Results and average values are rounded to three significant figures. Relative percent difference (%RPD) values are rounded to two significant figures. Because of rounding, values may vary slightly from those listed in the raw data. Field matrix spikes meeting the method acceptance criteria of 30%, demonstrate that the method is appropriate for the given matrix. All field matrix spike samples and surrogate recovery standards met method acceptance criteria except where noted below. DAL-GW-ACM2; the FMS sample (5 ng/mL) was not appropriate for PFBS; however, the surrogate recovery standard 13C4-PFOS met method acceptance criteria. No additional QC samples were prepared. PAGE 13 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 10. DAL GW ACI 131213 (1) 3M LIMS ID Description ISO13-07-11-001 DAL-GW-ACI-0-131213 ISO13-07-11-002 DAL-GW-ACI-DB-131213 ISO13-07-11-003 DAL-GW-ACI-FMS-131213 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 1840 NA 1820 NA 4200 95.6 1830 ng/mL 1.1% Concentration (ng/mL) %Recovery 1330 NA 1360 NA 3690 93.6 1350 ng/mL 2.2% 3M LIMS ID Description ISO13-07-11-001 DAL-GW-ACI-0-131213 ISO13-07-11-002 DAL-GW-ACI-DB-131213 ISO13-07-11-003 DAL-GW-ACI-FMS-131213 Average Concentration (ng/mL) %RPD PFHS PFOS Concentration (ng/mL) %Recovery 687 NA 703 NA 3210 100 695 ng/mL 2.3% Concentration (ng/mL) %Recovery 1960 NA 1980 NA 4780 112 1970 ng/mL 1.0% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-11-001 DAL-GW-ACI-0-131213 ISO13-07-11-002 DAL-GW-ACI-DB-131213 ISO13-07-11-003 DAL-GW-ACI-FMS-131213 Average Concentration (ng/mL) %RSD %Recovery 94.2 93.1 89.7 92.3% 2.5% %Recovery 110 115 110 112% 2.6% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 14 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 11. DAL GW ACM2 131213 3M LIMS ID Description ISO13-07-11-004 DAL-GW-ACM2-0-131213 ISO13-07-11-005 DAL-GW-ACM2-DB-131213 ISO13-07-11-006 DAL-GW-ACM2-FMS-131213 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-11-004 DAL-GW-ACM2-0-131213 ISO13-07-11-005 DAL-GW-ACM2-DB-131213 ISO13-07-11-006 DAL-GW-ACM2-FMS-131213 Average Concentration (ng/mL) %RPD PFOA (1) PFBS (2) Concentration (ng/mL) %Recovery 0.0729 NA 0.0775 NA 5.51 110 0.0752 ng/mL 6.1% Concentration (ng/mL) %Recovery 1430 NA 1440 NA 1460 NC 1440 ng/mL 0.69% PFHS (1) PFOS (1) Concentration (ng/mL) %Recovery 0.0587 NA 0.0829 NA 5.47 108 0.0708 ng/mL 34% (3) Concentration (ng/mL) %Recovery 0.531 NA 0.606 NA 6.00 109 0.569 ng/mL 13% 13C4-PFOA (1) 13C4-PFOS (1) 3M LIMS ID Description ISO13-07-11-004 DAL-GW-ACM2-0-131213 ISO13-07-11-005 DAL-GW-ACM2-DB-131213 ISO13-07-11-006 DAL-GW-ACM2-FMS-131213 Average Concentration (ng/mL) %RSD %Recovery 110 105 108 108% 2.3% %Recovery 102 93.6 88.3 94.6% 7.3% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration. (1) Samples were analyzed by internal standard calibration. (2) Samples were analyzed by external standard calibration. (3) Sample/sample duplicate RPD did not meet acceptance criteria of <20%. PAGE 15 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 12. DAL GW ACE 131213 (1) 3M LIMS ID Description ISO13-07-11-007 DAL-GW-ACE-0-131213 ISO13-07-11-008 DAL-GW-ACE-DB-131213 ISO13-07-11-009 DAL-GW-ACE-FMS-131213 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-11-007 DAL-GW-ACE-0-131213 ISO13-07-11-008 DAL-GW-ACE-DB-131213 ISO13-07-11-009 DAL-GW-ACE-FMS-131213 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 0.0728 NA 0.0868 NA 5.22 104 0.0798 ng/mL 18% Concentration (ng/mL) %Recovery 0.0725 NA 0.0806 NA 4.65 91.5 0.0766 ng/mL 11% PFHS PFOS Concentration (ng/mL) %Recovery <0.0500 NA 0.0648 NA 4.72 93.1 0.0648 ng/mL Concentration (ng/mL) %Recovery 0.0276 NA 0.0330 NA 4.75 94.6 0.0303 ng/mL 18% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-11-007 DAL-GW-ACE-0-131213 ISO13-07-11-008 DAL-GW-ACE-DB-131213 ISO13-07-11-009 DAL-GW-ACE-FMS-131213 Average Concentration (ng/mL) %RSD %Recovery 98.5 102 104 100% 2.8% %Recovery 112 91.7 94.1 102% 11% NA = Not Applicable (1) Samples were analyzed by internal standard calibration. PAGE 16 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 13. DAL GW WW8R 131213 (1) 3M LIMS ID Description ISO13-07-11-010 DAL-GW-WW8R-0-131213 ISO13-07-11-011 DAL-GW-WW8R-DB-131213 ISO13-07-11-012 DAL-GW-WW8R-FMS-131213 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-11-010 DAL-GW-WW8R-0-131213 ISO13-07-11 -011 DAL-GW-WW8R-DB-131213 ISO13-07-11-012 DAL-GW-WW8R-FMS-131213 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 2700 NA 2730 NA 4930 89.1 2720 ng/mL 1.1% Concentration (ng/mL) %Recovery 316 NA 316 NA 2640 93.0 316 ng/mL 0.0% PFHS PFOS Concentration (ng/mL) %Recovery 1260 NA 1270 NA 3610 93.2 1270 ng/mL 0.79% Concentration (ng/mL) %Recovery 4070 NA 4050 NA 6490 97.2 4060 ng/mL 0.49% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-11-010 DAL-GW-WW8R-0-131213 ISO13-07-11 -011 DAL-GW-WW8R-DB-131213 ISO13-07-11-012 DAL-GW-WW8R-FMS-131213 Average Concentration (ng/mL) %RSD %Recovery 90.6 86.5 82.7 86.6% 4.6% %Recovery 108 107 101 105% 3.6% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 17 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 14. DAL GW WW9R 131213 (1) 3M LIMS ID Description ISO13-07-11-013 DAL-GW-WW9R-0-131213 ISO13-07-11-014 DAL-GW-WW9R-DB-131213 ISO13-07-11-015 DAL-GW-WW9R-FMS-131213 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-11-013 DAL-GW-WW9R-0-131213 ISO13-07-11-014 DAL-GW-WW9R-DB-131213 ISO13-07-11-015 DAL-GW-WW9R-FMS-131213 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 2670 NA 2700 NA 4820 85.9 2690 ng/mL 1.1% Concentration (ng/mL) %Recovery 264 NA 253 NA 2590 93.2 259 ng/mL 4.2% PFHS PFOS Concentration (ng/mL) %Recovery 1170 NA 1160 NA 3460 91.2 1170 ng/mL 0.85% Concentration (ng/mL) %Recovery 4160 NA 4210 NA 6640 98.0 4190 ng/mL 1.2% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-11-013 DAL-GW-WW9R-0-131213 ISO13-07-11-014 DAL-GW-WW9R-DB-131213 ISO13-07-11-015 DAL-GW-WW9R-FMS-131213 Average Concentration (ng/mL) %RSD %Recovery 88.3 89.6 85.5 87.8% 2.4% %Recovery 111 105 106 107% 3.0% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 18 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 15. DAL GW WW10R 131213 (1) 3M LIMS ID Description ISO13-07-11-016 DAL-GW-WW10R-0-131213 ISO13-07-11-017 DAL-GW-WW10R-DB-131213 ISO13-07-11-018 DAL-GW-WW10R-FMS-131213 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-11-016 DAL-GW-WW10R-0-131213 ISO13-07-11-017 DAL-GW-WW10R-DB-131213 ISO13-07-11-018 DAL-GW-WW10R-FMS-131213 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 1910 NA 1870 NA 3940 82.7 1890 ng/mL 2.1% Concentration (ng/mL) %Recovery 239 NA 238 NA 2460 88.8 239 ng/mL 0.42% PFHS PFOS Concentration (ng/mL) %Recovery 889 NA 880 NA 3110 88.6 885 ng/mL 1.0% Concentration (ng/mL) %Recovery 2950 NA 2890 NA 5110 87.6 2920 ng/mL 2.1% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-11-016 DAL-GW-WW10R-0-131213 ISO13-07-11-017 DAL-GW-WW10R-DB-131213 ISO13-07-11-018 DAL-GW-WW10R-FMS-131213 Average Concentration (ng/mL) %RSD %Recovery 90.3 86.8 84.2 87.1% 3.5% %Recovery 109 102 111 107% 4.4% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 19 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 16. DAL GW WW11R 131213 (1) 3M LIMS ID Description ISO13-07-11-019 DAL-GW-WW11R-0-131213 ISO13-07-11-020 DAL-GW-WW11R-DB-131213 ISO13-07-11-021 DAL-GW-WW11R-FMS-131213 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-11-019 DAL-GW-WW11 R-0-131213 ISO13-07-11-020 DAL-GW-WW11 R-DB-131213 ISO13-07-11-021 DAL-GW-WW11 R-FMS-131213 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 1050 NA 1060 NA 3260 88.7 1060 ng/mL 0.94% Concentration (ng/mL) %Recovery 200 NA 195 NA 2420 88.9 198 ng/mL 2.5% PFHS PFOS Concentration (ng/mL) %Recovery 515 NA 508 NA 2730 88.4 512 ng/mL 1.4% Concentration (ng/mL) %Recovery 1570 NA 1560 NA 3940 94.8 1570 ng/mL 0.64% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-11-019 DAL-GW-WW11 R-0-131213 ISO13-07-11-020 DAL-GW-WW11 R-DB-131213 ISO13-07-11-021 DAL-GW-WW11 R-FMS-131213 Average Concentration (ng/mL) %RSD %Recovery 91.7 90.0 84.7 88.8% 4.1% %Recovery 108 110 104 107% 2.9% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 20 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Table 17. Trip Blank Results 3M LIMS ID ISO13-07-11-022 ISO13-07-11-023 ISO13-07-11-024 Description DAL-GW-TRI P-0-131213 DAL-GW-TRIP-LS-131213 DAL-GW-TRI P-HS-131213 3M LIMS ID ISO13-07-11-022 ISO13-07-11-023 ISO13-07-11-024 Description DAL-GW-TRI P-0-131213 DAL-GW-TRI P-LS-131213 DAL-GW-TRI P-HS-131213 PFOA PFBS Concentration (ng/mL) <0.0240 (1) 4.37 (2) 2200 (2) %Recovery NA 88.1 88.7 Concentration (ng/mL) <0.0250 (1) 4.74 (2) 2110 (2) %Recovery NA 94.8 84.4 PFHS PFOS Concentration (ng/mL) <0.0500 (1) 4.45 (2) 2160 (2) %Recovery NA 89.0 86.1 Concentration (ng/mL) <0.0232 (1) 4.54 (2) 2420 (2) %Recovery NA 91.0 96.8 13C4-PFOA 13C4-PFOS 3M LIMS ID ISO13-07-11-022 ISO13-07-11-023 ISO13-07-11-024 Description DAL-GW-TRI P-0-131213 DAL-GW-TRI P-LS-131213 DAL-GW-TRI P-HS-131213 %Recovery 115 (1) 100 (2) 94.0 (2) %Recovery 92.0 (1) 114 (2) 115 (2) NA = Not Applicable (1) Samples were analyzed by internal standard calibration. (2) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 21 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 5 Conclusion Laboratory control spikes were used to determine the analytical method accuracy and precision for all analytes. The accuracy and precision were then used to estimate the method uncertainty for the results. Field matrix spike recoveries demonstrated that the analytical method was appropriate for the given sample matrix. Analysis was completed using 3M Environmental Laboratory Method ETS-8044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Analytical results are reported in Table 1 and 10-17 of this report. 6 Data / Sample Retention All remaining sample and associated project data (hardcopy and electronic) will be archived according to 3M Environmental Laboratory standard operating procedures. 7 Attachments Attachment A: Analyte T rend Data for select sampling points at the Decatur Ground Water T reatment Plant (GWTP) GAC System. 8 Signatures Digitally signed by Susan T. Wolf DN: c=US, st=MN, l=St. Paul, ou=3M Environmental Laboratory - authenticated by LRA, email=stwolf@mmm.com, o=3M, cn=Susan T. Wolf Reason: I am the author of this document Date: 2014.01.27 11:22:30 ~06'00' Susan T. Wolf, 3M Principal Analytical Investigator Digitally signed by Wiliam K. Reagen DN: c=US, st=MN, l=St. Paul, ou=Laboratory Director, ou=3M Environmental Laboratory - authenticated by LRA, email=wkreagen@mmm.com, o=3M, cn=Wlliam K. Reagen Reason: I am approving this document Date: 2014.01.27 12:03:47-06'00' William K. Reagen, Ph.D., 3M Environmental Laboratory Technical Director Date Date The 3M Environmental Laboratory's Quality Assurance Unit has audited the data and report for this project. Digitally signed by Daryl K. Peterson DN: c=US, st=MN, l=St. Paul, ou=3M Environmental Laboratory - authenticated by LRA, email=dpeterson2@mmm.com, o=3M, cn=Daryl K. Peterson Date: 2014.01.28 08:54:12 -06'00' Quality Assurance Representative Date This test report shall not be reproduced except in full, without written approval o f the 3M Environmental Laboratory. PAGE 22 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System ACI (Activated Carbon Influent) - Sample Results in ng/mL ACI PFOA PFBS PFHS PFOS 1/17/13 1910 588 895 1810 2/13/13 2300 830 1580 2940 3/27/13 2220 1060 1090 2490 4/29/13 1480 1360 777 1670 5/31/13 1860 1040 940 2150 6/27/13 1480 708 942 1590 7/23/13 1630 1230 749 1680 9/30/13 2320 356 1400 3240 10/28/13 1880 1590 866 2100 11/18/13 2190 1100 1330 2240 12/13/13 1830 1350 695 1970 ACE (Activated Carbon Effluent) - Sample Results in ng/mL ACE PFOA PFBS PFHS PFOS 1/17/13 <0.0240 <0.0250 <0.0250 <0.0232 2/13/13 0.124 0.0360 0.178 0.0329 3/27/13 0.0380 <0.0250 0.0477 <0.0232 4/29/13 0.0422 0.392 0.0570 <0.0232 5/31/13 0.0725 24.8 0.105 <0.0232 6/27/13 0.0717 111 0.118 <0.0232 7/23/13 0.0641 1960 0.0778 0.0277 9/30/13 0.115 1950 0.156 0.0452 10/28/13 0.231 0.379 0.180 0.0785 11/18/13 0.478 0.592 0.366 0.0726 12/13/13 0.0798 0.0766 0.0648 0.0303 PAGE 23 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW8R - Sample Results in ng/mL W W 8R PFOA PFBS PFHS PFOS 1/17/13 4350 410 1930 5710 2/13/13 3250 354 1900 4850 3/27/13 3640 385 1760 5120 4/29/13 3190 364 1610 4830 5/31/13 2760 289 1330 4180 6/27/13 2760 282 1340 4110 7/23/13 2640 263 1260 3910 9/30/13 2890 303 1370 4100 10/28/13 2830 312 1300 4410 11/18/13 3040 362 1440 4750 12/13/13 2720 316 1270 4060 WW9R - Sample Results in ng/mL FC Charting to r DAL WW9R 500OH------------------------------------------------------------------------------------ PFOA------- -------PFOS------- -------- PFBS------- -------- PFHS------- W W 9R PFOA PFBS PFHS PFOS 1/17/13 2710 184 954 3690 2/13/13 2850 236 1400 4100 3/27/13 3330 278 1440 4660 4/29/13 2650 244 1200 4340 5/31/13 2660 226 1120 4210 6/27/13 2630 225 1140 4150 7/23/13 2410 212 1030 3670 9/30/13 2730 249 1220 4200 10/28/13 2820 286 1280 4380 11/18/13 2950 305 1340 4540 12/13/13 2690 259 1170 4190 PAGE 24 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-11 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW10R - Sample Results in ng/mL W W 10R PFOA PFBS PFHS PFOS 9/30/2013 2070 247 1030 2770 10/28/2013 2150 264 1030 3160 11/18/2013 2400 303 1120 3890 12/13/2013 1890 239 885 2920 WW11R - Sample Results in ng/mL W W 11R PFOA PFBS PFHS PFOS 9/30/2013 1720 299 1000 2200 10/28/2013 1100 240 511 1670 11/18/2013 1320 287 680 1850 12/13/2013 1060 198 512 1570 PAGE 25 OF 25