Pydraul* straight synthetics do more than SAFEGUARD your hydraulic operation-they are PREVENTIVE MAINTENANCE fluids that will give the greatest reliability in operation ... and eliminate your major main tenance and down-time costs if you are now using a water-based fluid.
DSW 321741 STLCOPCB4073392
Include Pydraul straight synthetics in your PREVENTIVE MAINTENANCE program
Preventive maintenance makes sense! Preventive maintenance is your weapon against down-time, the number one enemy of production. In hydraulics, preventive maintenance usually means routine changing of pumps and filters and tightening valves to cut down leaks. In fire-resistant hydraulic operations, there's another often overlooked factor --the fluid itself. Pydraul straight synthetics protect your plant, equipment and personnel against fire hazards in hydraulic equipment. So important is this safety aspect that some military contracts now given to die casters go only to those firms using a fire-resistant fluid so that equipment fires cannot hamper delivery of essential parts. But Pydraul fluids do more than provide fire safety. Pydraul straight synthetics have built-in "preventive maintenance" -- they eliminate the major mainte nance troubles of fire-resistant fluids that contain water. If you are now considering using a fire-resistant fluid, it will pay you to select a Pydraul fluid. Pydraul fluids deliver the safety you need PLUS the per formance you have a right to expect.
DSVV321?42
1
STLCOPCB4073393
Pydraul straight synthetics exceed water-glycol fluids in the properties that
count most in preventive maintenance.
Lubricity under heavy loads Oxidative stability............... Thermal stability................... Foaming resistance.............. Vapor pressure..................... Oil compatibility...................
PYDRAUL
E E E E Very low E
WATER-GLYCOL FLUID
P P P P High P
Here's why...
Pydraul fire-resistant hydraulic fluids are chemically synthesized--tailored to the job--not just mixtures of flammable lubricant with water and additives. You can blame the failure of all water-based products to match Pydraul per formance on the water. It's the water that causes corrosion and rust. It's the water that evaporates to upset the additive balance and create high vapor pressures and cavitation in pumps. It's the water that causes high wear and replacement of pumps through inadequate lubrication.
But without the water, the water-based fluids would not be fire resistant! So you can't escape the consequences.. With water-based fluids, you pay for this type of fire resistance many times over in maintenance costs and lost produc tion in down-time incidents.
2
STLCOPCB4073394
In developing the Pydraul fluids, Monsanto chemists had just one goal: Find a fluid that lubricates like a premium petroleum oil . . . with inherent fire resistance. The final result--an entire series of fire-resistant fluids that do just that... lubricate like oil. In over 500,000,000 machine hours of industrial serv ice, Pydraul fluids have earned a reputation as dependable lubricants. Manu facturers of pumps and other equipment have confirmed that Pydraul fluids give reliable service. Manufacturers that refused to issue warranties on 3000 psi pumps for water-based fluids, issued full warranties for pumps on Pydraul.
The test results below show the difference. Pydraul fluids lubricate better than water-glycol fluids and are outstanding under high loads.
Pydraul A-200 Water-Glycol
ALMEN WEAR
LmOSg.S
LOAD psi
ALMEN LOAD
LOAD psi
TORQUE Lbs.
TIMKEN LOAD
PASSING LOAD FILM STRENGTH Lbs. P$i
1.3 4000 24,000 41
50 16,340
2.0 2500 3,000 11
10 5,200
Pydraul A-200 Water-Glycol
SHELL 4-BALL WEAR. mm. 630 RPM..
1 HR.. 167" F. STEEL-ON-STEEL
10 Eg.
40 kg.
0.29
0.43
0.72
0.91
DSW 321744
3
STLCOPCB4073395
BETTER THERMAL AND OXIDATIVE STABILITY
means an end to fluid monitoring, corrosion and an extra "cushion" at high temperatures. Pydraul fluids stand up exceedingly well under operating temperatures--don't corrode, don't cause rust. In 800,000,000 machine hours of service, Pydraul has never caused corrosion of any hydraulic system! Of course, there's no water loss to monitor or additive system to keep in balance. Pydraul fluids do not react with various metals found in hydraulic systems. Good oxidation stability comes from the fire-resistant nature of Pydraul since burning is simply rapid oxidation. The following tests were run according to the procedures given in the Military Specification MIL-H-5606A (oil, hydraulic, aircraft, petroleum base). Strips of copper, iron, magnesium, aluminum and cadmium-plated steel were im mersed in Pydraul, the fluid heated to 250 F., and held at temperature for 168 hours. Air was bubbled through the fluid to allow oxidation of the metal strips. Though results vary somewhat, Pydraul A-200 is representative of all
STLCOPCB4073396
BETTER FOAMING RESISTANCE prevents
frothy build-up in reservoir and erratic equipment operation
Pydraul fluids have a much lower foaming tendency than water-based fluids, especially the water-glycol products which are known to cause considerable foam. Excessive foam in the reservoir can easily work its way into the system and cause poor pump operation and erratic response of the hydraulic mechan ism. And where excessive foam occurs, you find production timing off.
Pydraul fluids do not cause foaming problems. The figures below show the vast difference in foaming tendency of Pydraul A-200 and a typical waterglycol fluid.
Pydraul A-200 Water-Glycol
SAMPLE 1 75 F.
30
250
ASTM FOAM TEST D-B92 (ml. at 5 minutes) SAMPLE 2 200 F.
8
380
SAMPLE FROM No. 2 75" F.
35
150
DSW 321746
5
STLCOPCB4073397
BETTER COMPATIBILITY WITH OIL AND GREASES
prevents sludge formation and dogged filters
If oil or grease enters system
Oils and greases dissolve completely in Pydraul fluids, but added to waterglycol types, they form a sticky mass that can clog filters, block servo orifices or cause sluggish response. If a mechanic overgreases a fitting or adds petroleum oil to the hydraulic system, Pydraul systems don't malfunction. For best serv ice, the oil content should be kept below about seven per cent. Otherwise, fire resistance is lessened and seals and packings may swell. If the content goes above seven per cent, drain off part of the fluid and add fresh Pydraul. The drained fluid can be added gradually as make-up.
Effect of Oil or Grease on Fire-Resistant Hydraulic Fluids
Pydraul fluids
Water-Glycol Water-Emulsions Other straight synthetics
Oil and grease dissolves completely. Too much content may affect fire resistance and cause swell of pack ings and seals. Keep below about 7 per cent.
Oil and grases insoluble in any per centage. Forms a sticky mass which can clog filters, block servos.
Oil and grease are soluble but can cause the emulsion to break, leaving separate water and oil layers.
Oil and greases not completely solu ble. Can form viscous emulsions which starve pumps and bearings, slow down operation.
6 STLCOPCB4073398
Engineers working in missile hydraulics think this nonelectrolytic feature of Pydraul fluids is important to reliability. When you have electrical panels and numerous switches, electrolytic corrosion can bring trouble. Pydraul fluids themselves are good electrical insulators and protect against short circuits and electrolytic corrosion in the event of line breaks or sprays. In electrical proper ties, Pydraul fluids compare favorably with transformer fluids.
Dielectric strength at 60 cps, 0.1 in.. 25 C.
Resistivity, ohm-cm. 25 C.
100 C.
PYDRAUL A-200
33 KV
0.33 X 10' 0.09 X 10'
osw1748
I
I
STLCOPCB4073399
SUMMARY OF YEARLY MAINTENANCE JOBS REPORTED BY ONE
INDUSTRIAL FIRM
:a\ C L\
PYPRAU^
*10 MAINTENANCE CHECKS
Pydraul PREVENTIVE MAINTENANCE
properties
HERE'S PROOF - - of PREVENTIVE MAINTENANCE performance you get with Pydraul.
A large industrial firm operated two die casting machines during a 12-month test period. These machines were identical, located sideby-side, and made the same kind of castings. The only difference was in the fluids used. One machine used a water/glycol fluid, the other used Pydraul. The results below show how Pydraul drastically reduced maintenance jobs that plagued the machine operating on water-glycol fluid. But most important, the down-time incidents dropped by an even greater proportion. By eliminating the major maintenance jobs and down-time incidents, the firm was able to increase the production output of the die casting machine and lower maintenance costs at the same time. After this test, the firm converted ALL their die casting machines to Pydraul.
MAINTENANCE PERFORMED (DT indicates down-time)
clean filter....................................... replace filter..................................... remove scum from oil........................ clean compensator.......................... adjust compensator.......................... DT clean holding valve.......................... adjust holding valve........................ DT clean die, open & close valve.......... clean 1000= vol. pump........ ......... adjust 1000i vol. pump..,.......... adjust 2000if shot pump.............. DT clean 1000~ relief valve............ adjust lOOO^r relief valve.............. DT clean 2000^r relief valve................ adjust 2000relief valve.............. adjust prefill................................ DT rebuild 1000=i relief valve.............. DT rebuild 1000ii volume pump.......... DT replace rings in 1000ir pump........ DT rebuild 2000ir relief valve.............. DT replace seat & piston in holding valve add water, additive........................ DT remove oil, flush & refill..................
MACHINE #1 WATER-GLYCOL
MACHINE #2 PYDRAUL
41 . . . 10 1 .. 0 9 .. 0
13 ... 1
16 . .. 3
1 ... 1 2 .. . 1 1 .. . 0 1 .. . 0 10 . .. 2 22 . . . 4
20 . . . 1 21 1
16 4
23 9
13 9
10 30 20 20 10
. each 6 wks............ 0
. . . 2 . .............. 0
Total jobs required............................................220 ............ 41 Total down time incidents................................. 49 ............. 6
DsW 321749
8
STLCOPCB4073400
PydrauI straight synthetics can eliminate your major maintenance jobs if you are now using a water-based hydraulic fluid.
Check your maintenance reports. If these jobs are showing up with alarming - - '"'T regularity-
clean, adjust or rebuild relief valves remove sludgy hydraulic fluid, flush and refill remove scum from reservoir clean or adjust compensator clean sludge from filter check fluid, add water lost through evaporation check fluid, add additives lost through depletion
you can put PREVENTIVE MAINTENANCE to work by switching to Pydraul straight synthetics. In normal hydraulic operations, these jobs should not occur more frequently than two or three times each year. Yet maintenance reports often show they occur twice or more each month when water-based fluids are used. If your own reports show these chronic maintenance difficulties, you can solve the problem with Pydraul straight synthetics.
DSW 321750
Q
STLCOPCB4073401
You can count on Pydraul straight synthetics for
reliable performance.
-
In the last eleven years .. Pydraul fluids have operated over 800,000,000 machine hours. In this time, Pydraul has never caused or contributed to a fire in any type of equipment
More than 40 industrial plants have converted from water-based fluid to Pydraul for its proven perform ance advantages.
Users have reported maintenance tasks drop off sharply when they operate on Pydraul.
Pydraul has become the standard industrial fireresistant hydraulic fluid against which all others are judged, just as Monsanto's Skydrol is the standard of the aircraft industry.
SAFETY... PERFORMANCE ... ECONOMY
DSW 321751 10