Document G5j6dpOK7JK9XYmb2xQjj2kJ4
cot Or* Richard Osland
May 10, 1972
. Dr. j. Clarence Davies, III
:
Senior Staff Member
. ..
. Council for Environmental Quality
722 Jackson Place, U. W.
.
Washington, D. C. 20006
. r ;
'v
/ ' . ' ,
:
'
Dear Dr. Daviest
During the last two months our medical staff completed examinations oir 27 hourly and salaried workers who were engaged in the manufac ture of polychlorinated biphenyl in our Sauget, Illinois Plant.
'These 27 workers had various lengths of service in the department* The shortest was six months and the longest was 12 years. The average time in the department was slightly over five years* -
Of these 27 individuals 16 had no detoctable PCB's in the blood (using a method sensitive to 0.1 ppm) five had 0*1 ppm, two had 0.2 ppea, two had 0.3 ppm, one had 0.4 ppm, and one had 0.5 ppm.
'
Clinical examinations were entirely negative. Laboratory examinations
including blood counts and hematocrit, and clinical chemistries in
cluding glucose, urea nitrogen, creatinine, uric acid, calcium
phosphorus, SCOT, SGPT, LDH, alkaline phosphatase, bilirubin,
cholesterol and total protein, showed no pattern of illness. There
were some random high cholesterols, one high hemoglobin and one low
hemoglobin. In only ono case was the SGOT and SGPT elevated but
,
this individual showed no detectable PCS in his blood.
In summary, I can say that these workers were as healthy as any
cross section of our plant workers of the same age.
. *-
0 .`
, Sincerely, `'
;
REK/ln
R. Emmet Kelly, M. D. Medical Director
* EXHIBIT
1 K-6
6BRN0D199B
LEXOLDMONOOIRRQ
Monsanto INDUSTRIAL chemicals CO.
..... .......
D*Tt
E> St Tucker - S. Second Street- - 17-60
April 5, 1973
APR 101372
" R. E. Keller - TIB w. B. Papageorge - B2NK
fttMUNU
*
*
TO Dr. R. Emmet Kelly A2SA
. The analyses of all blood samples from Department 246 personnel for PCBs have been completed. The results are shown in the following table.
Sample Designation
/
3 4
/o
O. 3 '3
U
t
r x.
....
::
/ /t
f
//
/
s
.
/a . fc . . *
ip
PPg\ PCBS*
ND HD ND . ND ND .. . ND . ND . ND .. ND .. ND ND 0.3 ' ND nd : ND ND - . 0.1 ND 0.2 0.1 0.4 0.3 0.1 0.5 0.1 0.1 0.2
*PCBs calculated as Aroclor 1242 ND - Nona Detected <0.1 ppP\
Recovery studies conducted with blood samples spiked with
Aroclor 1242 and Aroclor 1254 in the 1-5 ppm range yielded
the following results# 94.1 + 7.2% and 103.2 + 5.5%,
respectively.
" . " .
No significant levels of Aroclor 1254 were found in any of the samples although all contained measurable levels of DDE# a DDT metabolite. The DDE levels found ranged from 3-42 ppb.'
E. S. Tucker I
6BRN001999
LEXOLDMONOOI870