Document G5Rovg6NY2QB1j10z4o9g7eVm

Burners, Oil Winslow Boiler & Engineering Co. Builders of Oil Burners CHICAGO 844 Rush St. NEW YORK Show Room: 46 E. 41st St. GALESBURG Illinois A WINSLOW INDUSTRIAL BURNER sizes oi motor blower units and also ot ** installation consists of a motor-blower burners. unit and a burner nozzle assembly. In specifying burners determine whether The motor blower unit may be located at any convenient point near the boilers and connected to the burner assembly, in front of the boilers, by oil and air piping of correctly proportioned sizes. The pump pulls the oil from the storage tank and delivers it at from 7 to 10 lb. pressure to the burners. At the same time the blower is supplying the required the boilers are to carry an overload. Ordi narily, steel boilers can be provided with burners rated at the boiler rating unless overloads are contemplated. On the other hand, cast iron boilers can usually be pro vided with burners rated at about 7.0 per cent of the boiler rating. This is due to the different methods of rating steel and cast iron boilers. air at low pressure, measured in ounces, to effect a thorough atomization of the oil. This burner is complete with a strainer, pressure gage, check valve, oil relief valve, motor, blower and pump unit. Single motor blower units handle a variety of burner assemblies. Where dual units are twinned the capacities are not only doubled but the plant is insured against any shut down. There are several Sliding Type The sliding type burner is particularly adapted to bake ovens, lead melting other special industrial installations. Equipped with a flex ible oil line permitting burner to be completely removed from slide base. 464 Winslow Boiler & Engineering Co. Burners, Oil Wherever possible specify two smaller burner nozzles even though one large one will do the work, so as to assure an easier control of fuel consumption. Frequently both burner nozzles will be used to build up steam pressure and then one can be cut off entirely. Where loads are apt to be variable the double burner nozzle is ideal. . The cut to the right shows the efficient method of attaining atomization. The oil travels down the central tube and impinges onto the rotating disc. It whirls centrifugal^ and strikes the heel of the revolving cup in a thin film. It then travels'along the inner wall of the cup to the rim where it is whirled.off at tremen dous speed, mixing with the air from the barrel and entering the boiler perfectly atomized. The cut also shows* the balanced rotating cup and revolving turbine wheel. Two sets.- of ball bearings between these units- insure low frictional resis tance and high speeds. The following .partial list of Winslow Burner assem blages will be of assistance in determining correct sizes for a large scope of work. The ratings in column five are based on 100 sq. ft. of steam radiation per horse power and represent the total load the burner can handle.' . Designation Alexander......... Amos............. Anthony........... Austin............... Barney.............. Benjamin........ Bernard............ blame............... Carl.................. Charles............. Lurtis. ............. Daniel............. David............... Dean................. Delbert............. Earl.................. Edward............. Elmer............... Eugene............. Frank............... Fred.................. Motor Blower Unit No. and Size. Burners B-60 B-60 B-60 B-60 1 T 10 2T 10 1 T 30 2 T 30 B-90 B-90 B-90 B-90 3T 10 3 T 30 2 T 30 2 T 40 B-120 B-120 B-120 1 T 70 4 T 10 3T30 B-180 B-180 B-180 B-180 5 T 10 4 T 30 3 T 40 2 T 70 B-300 B-300 B-300 B-300 8T 10 6 T 30 5 T 40 4 T 70 B-500 B-800 J T250 2 T 250 Maximum Steam Radiation 3500 5000 5000 7500 ` 9500 11,000 10,000 12.000 10,000 11,000 14,000 14,000 20,000 * 22,000 22,000 20,000 24,000 30.000 . 34,000 25,000 50,000 Approximate Motor-Unit ` Floor-Space. 24'x 24' 24' x 24' 24'x 24' 24'x 24' 24'x 24* 24'x 24' 24'x 24' 24'x 24' 24'x 24'24'x 24' 24'x 24' 28'x 28' 28'x 28' 28' x 28' 28'x 28' 28'x 28' 28' x 28' 28'x 28' 28' x 28' 28'x 28' 28' x 28' Approximate' Shipping . R P. -Weight 290 lbs. 265 lbs. 280 lbs. 285 lbs. 300 lbs. 315 lbs. 290 tbs. 305 lbs. Vi Yi VVil 1 1 1 1 310 lbs. 320 lbs. 330 lbs. 365 lbs. 355 lbs. 370 lbs. 365 lbs. ||A iI <'AA 2222 400 lbs. 425 lbs. 455 lbs. 460 lbs. 3 3 3 3 550 lbs. 650 lbs. 5 5 Pump ' Air . y*# 2' w 2' Va' 2' Vf 2" Vf 2' Vifif" 2' 2' Vf 2' y#' W w Vf 2i'Wk Vi" VVi'f Vf 1xWliA'A-m Vi* 3' Vi' 3' Vzm 3' Vf 3' 'Vki" 3' 3' In addition to the Winslow Industrial burner described here the Winslow Boiler & Engi neering Company manufacturers a complete line of fully automatic,-residential and apartment house burners. The electric ignition KLEEN-HEET.-burners. with the vacuum oil feed eliminating the usual basement auxiliary tank, are built in several sizes and are thus suitable for a great range of work. The Klebn-Heet GJ gas ignition burners, with out the vacuum feed but completely automatic in operation, are in four sizes. The No. 10 is rated at one thousand feet hot water and is suitable for the average home. The No. 6 is especially adapted to Arcolas and small domestic water heaters. Inquiries to the INDUSTRIAL DIVISION of the WINSLOW BOILER AND ENGINEERING COMPANY, 844 Rush Street, Chicago, Illinois, will be promptly answered. 465 s