Document G5Gy5EdyB8pyeYmGmDQ2EXxL7

PLAINTIFF'S EXHIBIT low pressure oil or gas INSULATED STEEL JACKET OPTIONAL 606,000 to (.530,000 Btuh IB psi steam -- 30 psi waff.**' 2S>O0F maximum This famous line of Kewanee boilers incorporates many proven features found in the Scottie Junior high pressure series. Substantial steel skids, heavy flange steel shell, cast iron flue doors, and generous furnace volumes are only a few of the many quality features that are built into the low pressure Scottie Junior series. Rear combustion chamber is heavily lined with refractory and designed with water back top; adapter mounting plate makes assembly with standard gas or oil burners easy. Insulated steel jacket is optional. The boiler is also available as a forced draft boiler-burner unit for oil, gas or oil-gas combination. A Shell, heads and furnace are fabricated from heavy flange steel. All welds in accordance with ASME Code. B Ample steam space, large unbroken disen gaging area and well spaced tubes eliminate violent agitation of water . . . insure rapid circulation, fast pick-up and constant sup ply of steam or hot water. C Adequate washout openings give access to waterside for cleaning and inspection. O Plain circular furnace has sufficient volume for complete combustion of fuels. E Rear combustion chamber . . . with high temperature refractory lining installed at the factory. Designed with water back top. F Hinged combustion chamber door with pyrex observation port. G Sturdy steel skids simplify handling and in stallation. No special foundation is needed. H Long gas travel, through the lengthy com bustion chamber, then back through the full length of heavy gage 3* tubes, assures maxi mum transfer of heat to boiler water. Refractory filled cast iron flue doors, mounted on heavy-duty hinges, provide easy access to fire tubes for cleaning and inspection. K Gas-tight smokebox of heavy gage steel . . . welded to boiler shell and gasketed cast iron flue doors make the Scottie Junior adaptable to forced draft firing. ratings mechanic a ity f i red -- oil or gas BOILER NUMBER Rating--steam sq ft --water . . ..........sq ft --MBtuh.............. --steam per hour--212" F lb Firing rate--No. 2 oil**.. -- No. 5 oil** --gas gph gph MBtuh Heating surface Furnace volume .. Safety valve capacity . .sq ft cu ft lb steam per hr LM-18 2520 4040 606 624 5.4 5.0 757 99 16.5 606 ; LM-29 ! 4030 i . 6450 ! 967 5 996 | 8.6 1 8.0 j 1208 j 158 fi 217 967 LM-39 5480 8770 1316 1356 11.7 10.9 1645 215 29.9 1316 LM-45 6370 10200 1530 1577 13.6 12.7 1912 250 32.7 1530 LM-59 | LM-65 | LM-78 j LW-878 SUPERSEDED JULY 1, 1963 BY FOLLOWING MODELS LISTED IN BULLETIN 84-1-49A LW-879 LW-880 28471 Certified output. "Based on 140,000 Btu No. 2 Oil--150.000 Btu No. 5 Oil. Standard equipment--Factory installed rear combustion chamber. Hinged rear combustion chamber door with pyrex observation port. Flue cleaner with handle. Standard burner mounting plate with secondary air opening and standard refractory ring for oil burning. Plain burner mounting plate only (less refractory) for gas burning. Gas-tight steel front smokebox with insulated cast iron gasketed flue doors; steel skids; lifting loops. Standard equipment subject to change without notice. Standard steam trimmings--Safety valve as required by ASME Code; steam gage with siphon and cock; water column with water gage. Standard water trimmings--Relief valve(s) as required by ASME Code. Optional equipment--Insulated jacket; spinner blades; combination water column and low water cut-off; combination water column, pump control and low water cut-off; hot water heating coil. BULLETIN 84-2-49A Supersedes Bulletin 3218-2 scottie junior low pressure oil or gas dimensions and data cinches) BOILER NUMBER A--Boiler--inside diameter.......................... B-- --width overall ....................... C-- --length. D--Steam supply height ... E--Smoke outlet height . . F--Water column height.............................. G--Water line height.............. H--Lifting loop height.. J--Steam supply K--Safety valve . . M--Return, each side N --Drain. .. 0--Smoke outlet--outside width . P-- --outside length. R--Furnace--height S-- --inside diameter . . . T--Hole diameter--oil burner refractory U -- Base--location V-- --width W-- --length. X-- --extension . .. ... Y--Floor to boiler___ .. Z--Rear door clearance ... AA--Tube replacement space--front BB-- --rear . . Breeching diameter. . . Stack--diameter............ --height (ft) .............................. Steam supply size Return size (two)..................... Drain size Water column size Outside surface to cover sqft Approximate weight . . lbs LM-18 42 48% 82% 59% 62% 47% 49% 64% 27 20 42 V2 32% 8% 24% 29% 18 7 7 36 86% 18 16 39 39 22 17 14 15-0 4 4 1% 1 61 2800 LM-29 42 48% 112% 59% 62% 47% 49% 64% 33 20 44% 32% 8% 24% 29% 18 7 36 II6V2 18 16 39 69 5P/2 18 15 20-0 4 4 1% 88 3400 LM-39 48 54% 118% 70 68% 52 54 70% 35 20 51% 36 V? 10% 26% 30% 20 7% 11% 42 116% 18 16 44 67 48 20 17 20-0 6* 4 1% 105 4800 LM-45 48 54% 131% 70 68% 52 54 70% 35 20 51% 36% 10% 26% 30% 20 7% 11% 42 129% 18 16 44 80 61 20 18 20-0 6* 4 1% 1 119 5400 *150 lb American Standard Flange. **Front and rear of boiler and smokebox NOT included. LM-59 LM-65 LM-78 i LM-92 SUPERSEDED JULY 1, 1963 BY FOLLOWING MODELS LISTED IN BULLETIN 84-1-49A LW-878 LW-879 LW-880 LW-881 American ~Si^ndm`d SAILS OmCFS IN ALL PRINCIPAL CITICS Executive Offices: Detroit 32, Michigan in Canada: American-Standard Products (Canada) Ltd. Toronto 4, Ontario Engineered Products 28474 AMERICAN RADIATOR A STANDARD SANITARY CORPORATION Copyright 1963, by American Radiator & Standard Sanitary Corporation 5M 10*63 ET Litho in U.S.A. v';