Document G5Gy5EdyB8pyeYmGmDQ2EXxL7
PLAINTIFF'S EXHIBIT
low pressure oil or gas
INSULATED STEEL JACKET OPTIONAL
606,000 to (.530,000 Btuh IB psi steam -- 30 psi waff.**' 2S>O0F maximum This famous line of Kewanee boilers incorporates many proven features found in the Scottie Junior high pressure series. Substantial steel skids, heavy flange steel shell, cast iron flue doors, and generous furnace volumes are only a few of the many quality features that are built into the low pressure Scottie Junior series. Rear combustion chamber is heavily lined with refractory and designed with water back top; adapter mounting plate makes assembly with standard gas or oil burners easy. Insulated steel jacket is optional. The boiler is also available as a forced draft boiler-burner unit for oil, gas or oil-gas combination.
A Shell, heads and furnace are fabricated from heavy flange steel. All welds in accordance with ASME Code.
B Ample steam space, large unbroken disen gaging area and well spaced tubes eliminate violent agitation of water . . . insure rapid circulation, fast pick-up and constant sup ply of steam or hot water.
C Adequate washout openings give access to waterside for cleaning and inspection.
O Plain circular furnace has sufficient volume for complete combustion of fuels.
E Rear combustion chamber . . . with high temperature refractory lining installed at the factory. Designed with water back top.
F Hinged combustion chamber door with pyrex observation port.
G Sturdy steel skids simplify handling and in stallation. No special foundation is needed.
H Long gas travel, through the lengthy com bustion chamber, then back through the full length of heavy gage 3* tubes, assures maxi mum transfer of heat to boiler water.
Refractory filled cast iron flue doors, mounted on heavy-duty hinges, provide easy access to fire tubes for cleaning and inspection.
K Gas-tight smokebox of heavy gage steel . . . welded to boiler shell and gasketed cast iron flue doors make the Scottie Junior adaptable to forced draft firing.
ratings mechanic a ity f i red -- oil or gas
BOILER NUMBER
Rating--steam
sq ft
--water
. . ..........sq ft
--MBtuh..............
--steam per hour--212" F
lb
Firing rate--No. 2 oil**.. -- No. 5 oil** --gas
gph
gph MBtuh
Heating surface Furnace volume
..
Safety valve capacity
. .sq ft cu ft
lb steam per hr
LM-18
2520 4040
606 624
5.4 5.0 757
99 16.5
606
; LM-29
! 4030 i
. 6450
! 967 5 996
| 8.6 1 8.0 j 1208
j 158
fi
217
967
LM-39
5480 8770 1316 1356
11.7 10.9 1645
215 29.9
1316
LM-45
6370
10200
1530 1577
13.6 12.7 1912
250 32.7
1530
LM-59 | LM-65 | LM-78 j
LW-878
SUPERSEDED JULY 1, 1963 BY FOLLOWING MODELS
LISTED IN BULLETIN 84-1-49A
LW-879
LW-880
28471
Certified output. "Based on 140,000 Btu No. 2 Oil--150.000 Btu No. 5 Oil.
Standard equipment--Factory installed rear combustion chamber. Hinged rear combustion chamber door with pyrex observation port. Flue cleaner with handle. Standard burner mounting plate with secondary air opening and standard refractory ring for oil burning. Plain burner mounting plate only (less refractory) for gas burning. Gas-tight steel front smokebox with insulated cast iron gasketed flue doors; steel skids; lifting loops.
Standard equipment subject to change without notice.
Standard steam trimmings--Safety valve as required by ASME Code; steam gage with siphon and cock; water column with water gage. Standard water trimmings--Relief valve(s) as required by ASME Code.
Optional equipment--Insulated jacket; spinner blades; combination water column and low water cut-off; combination water column, pump control and low water cut-off; hot water heating coil.
BULLETIN 84-2-49A Supersedes Bulletin 3218-2
scottie junior
low pressure oil or gas
dimensions and data cinches)
BOILER NUMBER
A--Boiler--inside diameter..........................
B--
--width overall
.......................
C-- --length.
D--Steam supply height
...
E--Smoke outlet height . .
F--Water column height..............................
G--Water line height..............
H--Lifting loop height..
J--Steam supply K--Safety valve . . M--Return, each side N --Drain.
..
0--Smoke outlet--outside width . P-- --outside length.
R--Furnace--height S-- --inside diameter . . . T--Hole diameter--oil burner refractory
U -- Base--location
V-- --width
W--
--length.
X-- --extension .
.. ...
Y--Floor to boiler___
..
Z--Rear door clearance
...
AA--Tube replacement space--front
BB--
--rear . .
Breeching diameter. . . Stack--diameter............
--height (ft) .............................. Steam supply size Return size (two)..................... Drain size
Water column size
Outside surface to cover
sqft
Approximate weight . .
lbs
LM-18
42 48% 82%
59% 62% 47% 49% 64%
27 20 42 V2 32%
8% 24%
29% 18
7
7 36 86% 18
16 39 39 22
17 14 15-0 4 4 1% 1
61
2800
LM-29
42 48% 112%
59% 62% 47% 49% 64%
33 20 44% 32%
8% 24%
29% 18
7 36 II6V2 18
16 39 69 5P/2
18 15 20-0 4 4
1%
88
3400
LM-39
48 54% 118%
70 68% 52 54 70%
35 20 51% 36 V?
10% 26%
30% 20
7%
11% 42 116% 18
16 44 67 48
20 17 20-0 6* 4 1%
105
4800
LM-45
48 54% 131%
70 68% 52 54 70%
35 20 51% 36%
10% 26%
30% 20
7%
11% 42 129% 18
16 44 80 61
20 18 20-0 6* 4 1%
1
119
5400
*150 lb American Standard Flange. **Front and rear of boiler and smokebox NOT included.
LM-59
LM-65
LM-78 i LM-92
SUPERSEDED JULY 1, 1963 BY FOLLOWING MODELS
LISTED IN BULLETIN 84-1-49A
LW-878
LW-879
LW-880
LW-881
American ~Si^ndm`d
SAILS OmCFS IN ALL PRINCIPAL CITICS
Executive Offices: Detroit 32, Michigan
in Canada: American-Standard Products (Canada) Ltd.
Toronto 4, Ontario
Engineered Products
28474
AMERICAN RADIATOR A STANDARD SANITARY CORPORATION
Copyright 1963, by American Radiator & Standard Sanitary Corporation
5M 10*63 ET
Litho in U.S.A. v';