Document G54eaM6jJYnwk34kbb84Lydgq

Pacific Steel BoileTc^mo^- tJZSTZZ... POrat*nrP"f'f"icC sS*,",' hHe,,a,ting B,,IlSTM"sc Clreula,,,,,, . " D.-- --"n 01 UNITED CTA-ng RADIATOR C08PORAt,o^ S,"^.".^ For Soft or Hard Coal, Gas or Wood For Burning Oil P A C I pj STEEL HEATING BOILERS Pacific Steel Heating r built for steam or hot water'hV" using soft coal, hard coal oil tUls wood as fuel. ' >1, gas, 0, They are constructed of steel , ng to the A. 5. M. E. Qxle forS?' low pressure steel heating bolwf Every joint and seam in the Parifif electrically welded and each boi l !5 Zbuilt and tested to a pressure m 13 times its normal working pressure . cLXSC:n'S'n f th First placed on the market in 1912 to K "T ^e,firSt Welded boilers to be offered for general use. Thou fhedfi afe,now " operation, many from the first days of the Corporation, and "?t one has failed to live up to the STM *M The catalog ratings on Pacific Boilers conform with the Steel Heating Boiler fnstitute Code for Rating Low Pressure Heating Boilers and are based on heat ing surface and grate area. Any Pacific Boiler will carry its full rated load in equivalent direct radiation. All forms Of load, including piping and maximum hot water heating loads, must be re duced to equivalent direct radiation and included with the actual radiation load before selecting boiler sizes. _ For hot water boilers figure ratings bo per cent greater than corresponding steam boiler ratings. On hot water boilers two outlets and two returns the same size as the corresponding steam boiler outlet are furnished. 618 Jc Sled Boiler Corporation Boilers, Steel PACIFIC SMOKELESS BOILERS Height Base ' jj Length for Ashpit | Width for Aihpit j Length Overall j W idth Overall Height Boiler Length Bate Size of Outlet, H Inches . |j i| ace, inimum Height, Stack, Feet Diameter Stack. 1 Inches I M Grate Area, 1 Square Feet 17 60 16.0 392 17 65 17.3 425 17 65 17.3 458 22 65 19,1 508 22 70 70.5 595 22 70 22.0 638 22 80 22.0 680 24 70 23.6 709 24 75 7.5.3 810 24 65 770 910 24 95 28.7 1011 28 75 76.5 865 28 75 7.8.3 989 too28 85 302 1113 28 32.1 1237 30 85 31,8 1184 30 85 33.9 1333 30 90 33.9 1482 30 100 360 1631 30 115 38 1 1780 33 100 40.4 1583 33 100 40.4 1759 33 100 40.4 1935 H 1 e a tin g S u rf I Square Feet .<? i JdS s j3 ti &'S-jj i/3 -05 s 6 3 96 57% 91 76% 533/, 12 41 47% 6 3 102 57% 91 82% 53% 12 45 47% 6 3 108 57% 91 88% 53% 12 43 47% 8 4 98 62% 98% 76'/$ 12 45 52% 8 4 110 62%. 98% -88% 58% 12 49 52% cn 124(4 ?A W8 8 4 116 ' 4 122 62% 98% 98# 94% 6587%^ 12 53 52% H 12 53 52% O 8 4 112% 108% 12 49 61 Z 84 70% 108/? 100% 67 . 12 53 61 lftWA8 4 136% 70% IO87? 112% 67 8 4 14814 70% 124% 67 12 3/ .61 12 61 61 >< VJ 8 4 113% 78% 120 88% 74% 15 49 68% Z . <8 4' 125% 78% 120 100% 74% 15 33 68% 8 4 137% 78% 120 112% 74% 15 57 68% 8 4 149% 78% 120 124% 74% 15 61 68% ' 77'A8 5 127 86 128% 100% 83% 15 .33 77% 8 5 139 86 128% 112% 83% 15 57 10 6 151 86 128% 124% 83% 15 57 77% 10 6 163 10 6 175 z86 128% 136% 83% 15 61 .77% 86 128% 148% 83% 15 65 77% 10 6 95% 142% 113% .96% 18 61 90% 10 6 95% 142% 125% 96% (8 61 90-4 10 6 168% 95% 142% 137% 96% 18 61 90% For Pacific Direct Draft or Oil Fired Boilers use the above specification. PACIFIC low water line direct draft and smokeless boilers fji MC *J a. 0 S.H.B.I 0 zi 1- ai U 4 s c/1 cn jC00 . b 8 Ji II id hV Vs !<* Q3 0 el iJ! CO IS aX s r a s s Oq *s n S-5 > C V-MI V.aJ ~ <5 -C ! 5- jb '5 a s- 0 A CQ 3 ca js `JSSi S .< CQ . J3 ' b I- J;X5 s s 1 3 - S3 Js -s S i* : -5 S3. -s Q& &. 2261 2262 1360 1550 5533%% 12 12 12 12 45 45 6.9 8.0 97 111 4 4 4 52% 34 4 58% 34 64% 45% 35%; 12 3?% S/`. 64% 51% 35% 12 45% 29% 2263 1720 53% 12 12 51) 8.0 123 4 . 4 64% 34 64% 57% 35% 12 31V, M% 2264 2100 53% 12 (2 55 9.1 150 4 2 79% 34 65% 64% 30% 12 47 24% 2291 2340 59% 14 13 55 9.3 167 5 3 74 39 72% 52% 36 12 37 .30 2292 2600 59% 14 J3 55 10.1 186 5 3 80 39 72% 58% 36 12 41 30 2293 2860 59% 14 13 60 10.9 204 6 3 86 39- 72% 64% 36 12 45 30 2294 3110 59% 14 13 60 10.9 m 5 3 92 39 72% 70% 36 12 45- 30 2295 3370 59% 14 13 60 11.8 241 5 3 98 2331 3630 17 16 60 12.5 259 6 3 83 2332 4350 .17 16 65 13 5 311 6 3 95 39 44 44 472% 76% 36 12 49. .30 83 a 12 45 28 83 12 49 2333 5080 68% 17 16 70 15.4 363 6 3 107 2334 58)0 68% 1/ 16 JO 16.3 415 6 3 119 44 44 83 82% 40% 12 57 34% 83 9 40# 12 61 W/ O 2401 6520 68 18 17 70 187 466 6 3 118 50 81% 94% 47 12 57 41 z 2402 2471 2472 6940 7880 8460 68 78 78 18 17 75 187 496 6 3 124 22 21 70 19.5 563 6 4 108 27 21 75 21 3 604 8 4 114 50 57% 9812%# "TO St 47 57% .92# 12 57 41 12 53 SB )< 12 57- V) 2473 2474 2521 2522 2323 2600 2601 9040 9620 10470 11820 12520 14110 16020 78 78 82 82 82 90 90 27 71 75 21.3 646 8 4 120 7? 21 8ft 27 6 687 8 4 126 57%' 57% 92# 94% 92# 100% 53# 53# 12 12 57 61- nil r <, 74 23 80 23 4 744 8 4 122 74 73 85 24 9 844 8 4 134 74 73 9ft 26 4 894 8 4 140 62% 62% 62% 98# 9Vfy W/s 941/C 106% 112% 58% 58%. 58% 12 12 12 57 .52# *L 61 52# 65 52#- tA 30 29 85 78 7 1008 8 4 124% 70% 108% 94% 67 30 29 90 30.4 1144 8 4 136% 70% "TO 106% 67 12 61 61 12 65 61 . n1 2602 16970 90 30 29 90 304 1212 8 4 142% 108% 112% 67 12 65 .61- s 2603 18870 90 30. 29 95 32.2 1348 8 4 1541% 108% 67 12 69 61 z 2671 20540 98% 37 31 95 34.0 1467 8 4 143% 120 74% 15 65 68% 2672 22780 98% 37 31 100 35 9 1627 10 5 155% 78% 120 124% 15 69 68% 2673 25000 37 31 110 37 8 1786 10 5 167% 78% 120 136% 74% 15 73 6vA 2674 27230 98% 37 31 115 39 6 1945 10 5 179% 78%' 120 148% 74% 15 77 2751 29020 106 36 35 105 40.5 2073 10 5 157 86 128% 124% 83% 15 69 77% 2752 51890 106 36 35 no 47.6 2278 12 6 169 86 128% 136% 83% 15 73 77*4 2753 34750 106 36 35 170 44.6 2482 12 6 181 86 128% .1481/, 83% 15 77 77% 8841 45490 120 8842 49980 120 8843 54470 120 40 39 115 40 39 120 40 39 125 2676 2940 3204 12 12 12 aS6 162% 95%. 142% 125% 96% 6 174% 95% 142% 137%. 6 186% 95% 142% 1491% 18 18 18 Pacific Boilers are constructed with smoke outlet at the rear and all of the tubes, both upper and lower banks, are cleaned or removed from the front of the boiler through the front flue doors. Space at rear of boiler is not necessary. Complete catalogs showing all types and sizes Pacific Boilers will be furnished on request. 619 y