FIRE-RESISTANT INDIRECT HEATING
Aroclor* 1248 is fire-resistant, It docs not support combustion up to its boiling range, 652-7250 F,, and has a high flash point 380 F.
Thus indirect heating with Aroclor greatly reduces plant fire hazard, thereby increasing worker safety and possibly preventing costly fire damage to plant and equipment.
Aroclor is used in the liquid phase at atmospheric pressure or at low pressures, and does not require costly high pressure equipment. Explosion hazard is eliminated.
Forced circulation indirect heating with Aroclor is efficient and uniform. It gives accurate control of heat put into the process, This often leads to increased production, lower costs, and better quality of the finished product.
The general purpose of this booklet is to assist you in evaluating the benefits of using Aroclor for indirect heating in your plant or processes.
0 360925
TOWOLDMON0030544 WATER_PCB-00015013
HISTORY OF INDIRECT HEATING WITH
In 1941, certain new manufacturing processes of the Mon santo Chemical Company required using a noncombustible heat transfer medium at pressures of 30 pounds per square inch or less and temperatures in the range of 500 to 600 F.
Monsanto's Aroclor 1---48 was the only commercial and economical material which met these requirements.
Complete success in operating these early heaters using Aroclor created more general interest in the benefits of a high temperature, fire-resistant, heat transfer agent for a variety of industrial applications.
Also about this time, heating design engineers had begun to advocate in this country the benefits of liquid phase high temperature heating.
Subsequently, leading manufacturers of heating equip ment began to build beaters constructed specifically to accomplish maximum efficiency and maximum operating temperature using Aroclor liquid.
TOWOLDMON0030545 WATER_PCB-00015014
A PARTIAL LIST OF PRESENT COMMERCIAL AROCLOR HEATING APPLICATIONS INCLUDES:
1 Ifeatimj; chemical process equipment, especially where flamma ble materials are huinlh d.
2. 1'ioce.ssing \auiishes and rt sins. 0 Molding plastics ,md ruTher materials. 1 I leating bituminous materials. a. Heating \s "jetahlo oils for drop-lining potato chips and nthi r
I ood proees-.it ig ; a Tat ions. b. Processing titanium and other netals. T. Indirect heating in the manufacture of dvestufls. S. Heating corrugating rolls. d. hulirect heating of distillation equipment. 10. Heatin'! panels for continuous vacuum halt drivers.
Fo assist industry with installation of indirect heatimj; svstems using Aroclor, a li.mdhook entitled. "Aroclor 12 IS ffcat Transfer Data", gi\ing engineering data is available liom Monsanto.
In addition, the names of leading heating design engineers and manufacturers 'duo '.-inld heaters for Aroclor will be supplied when desired.
Monsanto does not manufacture or supply equipment for heating with Aroclor.
0 U.0-C t
3I (I
TOWOLDMON0030546 WATER_PCB-00015015
SAFETY It is fire-resistant and operates at low pressures, not over 30 psi gauge.
ECONOMY Expensive pressurized heating equipment is not required.
EFFICIENCY Aroclor 1248 has good heat transfer properties and is efficient up to maximum temperature of 600 F.
03609^8
fll TOWOLDMON0030547
WATER_PCB-00015016
S1 M P LI CI TY
The heaters are characterized by simplicity of construction and operation. There is no vapor formation and consequently no traps, feed pumps, etc. to maintain. An open vented tank permits free expansion of the fluid and avoids all problems of feed regulation, vacuum systems, or condensers.
ACCURACY OF CONTROL
Accurate temperature control for heating and cooling is provided.
CONVENIENCE
Aroelor heating units are compact, space saving and may he fired with gas or oil or heated electrically. Convenient controls for safety and tem perature regulation are provided. The viscosity of the fluid permits pump ing at room temperatures.
0360929
5
TOWOLDMON0030548 WATER_PCB-00015017
TOWOLDMON0030549 WATEFLPCB-00015018
LIQUID PHASE LOW PRESSURE 3.00
MAXIMU M
Aroclor 1248 is used in the liquid phase at atmospheric pressure or not over 20 to 30 PSI gauge and up lo a maximum continuous operating temperature of 600c F.
HIGH BOILING FLUID
The maximum operating temperature is sufficiently below the 6525-725:> F. boiling range of Aroclor 1248 to assure a liquid condition at all times.
EXCELLENT HEAT STABILITY
Although Aroclor is very stable to heat, adequate forced circulation, (about 20 to 80 gpm depending on the size of the system) should be provided to protect the liquid against localized overheating. Fluid velocity should be about 5 to 8 feet per second.
FORCED CIRCULATION AVOIDS LOCALIZED OVERHEATING
Brief overheating may not be harmful but extended heat injury above 600' F. will result in an increase of viscosity and measurable dehydrohalogenation.
TIGHTLY CLOSED SYSTEM ELIMINATES VAPOR LEAKS AND ODOR
With the exception of an open vented expansion tank, the system must be completely closed and scaled tightly to prevent vapors and odor from entering workroom areas.
K0
Y AND FULL SYSTEM ELIMINATES SSISLE CORROSION
The system should be kept dry and free from moisture. It is desirable to keep the heater and piping full of Aroclor liquid at all points. This eliminates spaces where moist air might collect during shutdown periods, By following these simple precautions, possible corrosion is minimized or eliminated.
036093J
7
TOWOLDMON0030550 WATER_PCB-00015019
I
CHARACTERISTICS OF A TYPICAL HEATER
TAILORED TO FIT THE JOB
Heating equipment using Aroclor is selected or designed to meet the requirements of the process, whether it is large or small. The heating equipment ranges in size from small portable units which are usually electrically heated to large gas or oil fired units with capacities ranging from 250,000 to more than 10,000,000 R.t.u.'s per hour.
ADVANTAGES OF FORCED RECIRCULATION HEATERS
Especially in the case of large size heaters where the maximum operating temperature of 6002 F. is required, the forced recirculation heater is superior to any heater dependent on natural circulation. The forced circula tion system is engineered to give a positive, uniform fluid flow through all tubes fed from a header, whereas natural circulation units have no special design to equalize the flow in the heater tubes. Where natural circulation units are operated with thermal liquids, it is impossible to distribute the flow equally through all tubes. The thermal liquid seeks the shortest route to the discharge outlet,
Consequently, the longer tubes, because of their greater resistance to flow, are subject to overheating. This becomes an important consideration when such units are operated at the high temperature range prescribed for a given fluid and may result in decomposition of fractions of the thermal liquid.
Also, since the discharge temperature from the circuit through a
natural circulation unit is the average temperature of the short-circuited
fluid and the overheat ' " ` ' '
''
' ''
``
temperatures which ai
TOWOLDMON0030551 WATER_PCB-00015020
u\\\\
UNIFORM TEMPERATURE Forced recirculation thermal liquid heaters, which consist of groups of small diameter tubes of equal length and orificed for uniform flow, provide even temperature distribution through all tubes in the circuit. Small diameter tubes, which are not practical in natural circulation heaters because they limit capacity, have a distinct advantage in forced recirculation units. In the smaller tubes the volume of fluid from the surface film to the center of the tubes is less and therefore heating is more uniform than in larger diameter tubes.
The forced recirculation heater is designed to move the fluid at velocities of 5 to 8 feet per second. This high velocity and resulting turbulence, coupled with the small fluid content of the tubes assures high rates of heat transfer and extremely close control of the outlet temperature. Tolerances of plus or minus 2 F. or closer are possible.
ELIMINATES SLUGGISH FLOW Forced circulation eliminates dead spots or sluggish flow areas where localized overheating of the Aroclor may occur.
0360933
9I
TOWOLDMON0030552 WATER_PCB-00015021
HEATER SYSTEM COMPONENTS
1
The next four pages describe the main features of the typical piping diagram shown on pages 14 and 15. A summation of primary advantages of heating with Aroctor 1248 then follows.
THE HEATER FLOW CIRCUIT The flow circuit consists of a thermal liquid heater and a recirculation pump which discharges the fluid returned from the system into the upper header of the heater as shown in Figure 1.
THE PUMP All Aroclor heaters are designed to avoid direct flame impingement on the tubes, The recirculation pump may be any one of a number of standard centrifugal units designed for hot liquid service. The pump should be made of cast steel and have a water-cooled stuffing box and water-cooled bearings. The stuffing box should have room for at least eight rings of packing and a lantern ring. Durametalic No. D-110 or Garlock No. 234 may be used for packing the pump. Mechanical seals have also proved to be successful at elevated temperatures. An open non-overloading impeller is desirable, as it will handle the cool, more viscous liquid on starting the system better than a positive displacement type pump.
THE BURNERS Gas and light-oil burners are usually used. Heavy oil burners using bunker "C" oil usually require furnishing steam to preheat the oil.
INDUCED DRAFT FAN As an economy feature to eliminate the expense of building and main taining a high chimney, the heater is usually fitted with an induced draft fan. The products of combustion are discharged from the fan into an exhaust vent higher than surrounding buildings.
10
0360934
J
TOWOLDMON0030553 WATER_PCB-00015022
EXPANSION TANK
I FIG. 1
^ THE PIPING AND CONTROL CIRCUITS
AROCLOR FROM HEATER
AROCLOR TO HEATER
STEAM OR WATER OUTLET
JACKETED PIPE COOLER
WATER INLET
DRAIN
FILL PUMP
GAS
TEMP. GAUGES
AIR BURNER PILOT
HEATER
PIPING A typical heater piping and control circuit is shown in Figure 1. All piping larger than &-inch is flanged or welded; experience has shown that hot Aroclor penetrates screwed joints of larger sizes. Steel and cast steel are used throughout. Spiral wound stainless steel and asbestos gaskets are recommended for all connections. For operation in areas where the Aroclor temperature may drop so low as to make the fluid unusually viscous, it may be desirable to steam-jacket the Aroclor circulating lines to facilitate rapid start-up in cold weather (or "when needed"). Suitable safety provisions such as safety pop-off valves, must be installed in the steam jacket system to prevent pressure ruptures which would develop if any condensate remained in a closed system during subsequent high temperature operation.
|"
TOWOLDMON0030554 WATER_PCB-00015023
DIFFERENTIAL PRESSURE CONTROL SAFETY AND TEMPERATURE CONTROLS
Connected to the suction and discharge sides of the pump, this device shuts off the burner in case of pump failure or a broken pipe line. Any factor causing a decrease from the desired operating pressure will activate this device to shut down the burner.
TEMPERATURE CONTROL
This unit modulates the burner in response to temperature variation of the liquid.
FLAME FAILURE CONTROL
An electronic flame control apparatus pilots the flame and stops the burner in case of unsatisfactory combustion.
TEMPERATURE LIMIT CONTROL
This contains thermocouples attached to discharge ends of the tubes at critical points. Excessive temperature rise induces the control to shut down the burner.
PUMP MOTOR STARTER
The motor starter should be furnished with an auxiliary switch. The auxiliary switch is on the burner circuit so that any motor failure or short-circuit will stop the burner.
036093b
lfl TOWOLDMON0030555
WATER_PCB-00015024
$
LIQUID LEVEL CONTROL
This should be located at the highest point in the system, usually in the expansion tank. Its purpose is to shut off the burner in case of a liquid level drop in the system such as would result from a pipe break or excessive leakage at the pump.
AIR SAFETY SWITCH
This control is applied to the suction side of the induced draft fan. Its purpose is to stop the burner in case of fan motor bum-out or over heated bearings.
VENT TANK The vent tank or expansion vessel is located at the highest point in the system and "floats" on the line. It is best connected to the intake side of the pump as this tends to give a positive head on the pump. The Aroclor in the vent tank should be relatively cool. It acts as a seal. However, the tank should be closed and fitted with a vent pipe and elbow with a moisture trap to keep out moist air. The capacity of this tank is normally 25% of the volume of Aroclor in the system.
COOLER
A very useful adjunct to the system is a double pipe cooler on the outlet of the heater. By circulating water through the jacket, the Aroclor may be cooled and the temperature of the system lowered. This is helpful when it is necessary to cool a batch before removing it or when an exothermic reaction requires control.
0360937
13
TOWOLDMON0030556 WATER_PCB-00015025
TOWOLDMON0030557 WATER_PCB-00015026
WHAT iNDin e c r
HEAT j ,'< <5 V! TM
Ww developments and increased production requirements in the chemical am! process in dustries demand higher temperature heat mu; with safety, accuracy and economy. Tempera tures required are no longer practical with .steam due to the extreme pressures required, costly equipment, and extra controls 'needed.
To meet indirect heating requirements up to 600: F., Aroclor 1248 used in properly designed equipment will do the job accurately, efficiently, economically and without the hazards of fire or explosion. The heaters are of simple construction, easy to operate and maintain, ant! their com pactness saves space.
Indirect heating with Aroclor gives highly accurate temperature control. It simplifies proc ess operations, increases production rates and lowers costs.
0 3 b 0 ^ J '4
15
TOWOLDMON0030558 WATEFLPCB-00015027
SUMMARY OF BENEFITS FROM
16
0360^40
|
TOWOLDMON0030559 WATER_PCB-00015028
1. Safety from fire and explosion.
-2 Operating temperatures up to 600
F. in properly designed recircula tion heaters.
-3 Accurate and uniform temperature
control.
.4 Economy of heating, low cost non*
pressurized equipment, low main tenance, space savings, low fluid make-up.
5. Increased production. In some processes, production rates were increased as much as 50*.
6, Product uniformity results from more accurate temperature control.
.7 Reduced product cost results from
better control of quality.
3. Heating and cooling in the same equipment.
.9 Different individually controlled
temperatures at various user sta tions in the circuit gives flexibility.
.10 Simplicity of installation and oper
ation.
Far anglneerlng data or furlhor Information on th us# of Arodor 1248 for boat transfer, contact Monianto Chemical Company, Organic Chemicals Division, Post Offic# Sox 478, St. Louii, Missouri.
*/ * -
'