Document G2RZdy2m87eqaRENQegjBvO4

ANALYTICAL METHODOLOGY FOR POLYCHLORINATED BIPHENYLS FEBRUARY 1973 FOOD AND DRUG ADMINISTRATION ROCKVILLE, MARYLAND MGNS 078783 Determination of Polychlorinated Biphenyl Residues in Foods, Feeds, and Paper Products The following outline lists the steps in the analysis of foods, feeds, and paper products currently employed by the Food and Drug Administration for residues of polychlorinated biphenyls (PCB). In general, methodology for foods and feeds is that used in analyses for organochlorine pesticides, with auxiliary steps as necessary to separate residues of PCB and pesticides. Extraction of paper products takes advantage of the stability of PCB to treatment with alkali; electron capture GLC determination is the same as specified for food and feed analysis. Methodology for the analysis of food and feeds is described in the FDA Pesticide Analytical Manual Volume I (PAM I). This manual and its revisions are available on request from Food and Drug Administration, Office of the Associate Commissioner for Compliance, S600 Fishers Lane, Rockville, Maryland 20652. Description of the method for paper products and other techniques necessary to analysis for PCB residues are attached. Methodology for Analysis for PCB Residues Food and Feeds Paper Sample Preparation* PAM I, 141. Cut into about l/4"xl/4M pieces; thoroughly mixed. Attachment I Extraction PAM I, 211.13 or 212.13, depending on sample type Alcoholic alkali reflux Attachment I Cleanup CH3CN-petr ether partitioning and/or Florisil column chromatography: PAM I, 211.14 or 212.14, depending on sample type Florisil column chromatography when necessary Attachment 1 Auxiliary Procedures Separation from pesticide residues, when necessary: PAM I, 251. Supplemental cleanup, when necessary: PAM X, 211.15, Attachment II Determination Electron capture GLC: PAM X, 251.15 and 311 Attachments III, IV Electron capture GLC: PAM I, 311 Attachments III, IV MONS 07878* -2- Procedures Useful for Confirmation GLC with halogen specific detection Micro scale alkali reflux: Attachment II GLC with halogen specific detection TLC - see PAM I, 251.16 for references TLC - See PAM I, 251.16 for references Perchlorination Attachment V perchlorination: Attachment V General Attachment VI Attachment VI Care must be used to avoid contamination of a sample during sampling/ storage, or laboratory operations. In particular, storage containers should be checked before using to assure that no PCB are present. The multi - component nature of PCB residues challenges even an experienced residue analyst in the identification and quantitation of the residue. Quantitation of a residue (see attachment II) is made by comparing the magnitude of GLC response from the residue to the magnitude of response frco reference Aroclor(s) (Monsanto Company). Judgment must be made as to which reference Aroclor most closely resembles the GLC peak pattern detected in the sample. In many cases, particularly in animal tissue samples, the residue pattern may not resemble any single Aroclor and a choice must h>e made as to which Aroclor(s) would provide the most accurate result. Since the chioice of auxiliary procedures depends to some degree on the identity of the residue, as discussed in PAM I, 251.16, the analyst must develop a high degree of skill in the application of this type of methodology and an ability to interpret GLC chromatograms correctly. The limits of detectability of the metliods are dependent upon: (1) the sensitivity of the determinative step (GLC) to the particular PCB mixture (Aroclor); and (2) the weight equivalent of sample injected for GLC. The magnitude of electron capture response to a given quantity of Aroclor 1242 is about one third of the response to the same quantity of Aroclor 1254. Therefore in the determination of residues exhibiting GLC patterns similar to Aroclor 1242, Injection of a larger weight equivalent of sample is required than for residues similar in GLC pattern to Aroclor 1254. When using the electron capture - GLC sensitivity fixed by the parameters defined in PAM I 311.2, the following sample weight equivalents should be Injected in order to obtain GLC response sufficient for detection and quantitation of residues similar to Aroclor 1242 at the tolerance levels:* *OAfS 0 78 785 -3- Products Milk (fat) Dairy Products (fat) Poultry (fat) W Complete and finished animal feeds Animal feed components Fish and shellfish Infant and junior foods Paper food packaging material Approximate milligrams sample equivalent for EOGLC 6 8 4 40 100 10 4 100 2 U.S. Food and Drug Administration January 22, 1973 HONS 078786 ATTACHMENT I Extraction and Cleanup for Determination of PCB in Paper and Paperboard By Susan J.v. Young, Charles Finsterwalder*, and Jerry A. Burke, Division of Chemistry and Physics, Food and Drug Administration, Washington, D,C. 20204; *Food and Drug Administration, 1141 Central Parkway, Cincinnati, Ohio 45202 (To be submitted to Journal of Official Analytical Chemists.) METHOD Apparatus (a) West condenser .->-400 me jacket length with g inner drip joint to fit Erlenmeyer. (b) Erlenmeyer flask.--250 ml with g outer joint to fit West condenser. (c) Separatory funnel.--250 ml with Teflon stopcock. (d) Chromatographic column.--with Teflon stopcock and coarse fritted plate, 22 mm id x 300 mm (Kontes Glass Co. Vineland, N.J., No. K-420540, size 233 or equiv.) (e) chromatographic column.--plain, 22 mn id x 300 mm (Kontes Glass Co. Vineland, N.J., No. K-420300, site 21 or equiv.) (f) Kuderna-Danish concentrator.--500 ml capacity with Snyder column and volumetric and graduated receiving tube. (Kontes Glass Co. Nos. K-621400 and K-570050 or equiv.) (g) Gas chromatograph.--Equipped with electron capture detector and 6*x4 mm id glass column containing either (1) 10% DC-200 or (2) ltl mixture of 15% QF-1 + 10% DC-200 on 60-100 mesh Chromosorb W(HP). Operating conditions: N2flow, 120 ml/fain; temperatures, column and detector 200C, injector 225C> concentric design electron capture detector operated at dc voltage to cause 1/2 full scale recorder deflection for 1 ng heptachlor epoxide when full scale deflection is lxl0~9 amp. . MCNS 07876? -2- Reagents (a) Florisil.*--60/100 PR Grade: Floridin Co, 3 Penn. Center Blvd., Pittsburgh# Pa. 15235. Transfer Immediately from bulk container to glass containers with glass stoppered or foil lined screw top lids and >tore in the dark. Heat at least 5 hours but preferably overnight at 130 C before uee. Store at 130C in glass stoppered or foil covered bottles. Alternatively, store stoppered container in desiccator at room temperature and reheat at 130C after two days. (b) Potassium hydroxide.--Anhydrous pellets. (c) Ethanol.--USP 95% (methanol, redistilled in glass may be substituted.) (d) Alcoholic KOH reflux reagent.--Prepare a 2% (g/ml) solution of KOH in ethanol. (e) Petroleum ether.--Suitable for use with electron capture gas chromatography (Burdick and Jackson Laboratories Inc., 1953, S. Harvey St., Muskegon, Mich. 49442 or equiv.) (f) Polychlorinated biphenyls.--Cosinercial mixtures (Aroclors) for reference in gas chromatographic determination. (Monsanto Company, St. Louis, Mo.) Attraction Paper sample should be cut into pieces no larger than about l/4"xl/4" and thoroughly mixed. Weigh lOg of the cut up and well mixed paper materiel into 125 ml Erlenmeyer flask. Do not pack sample tightly. (See note below if the volume of lOg of sample material is greater than about 50 ml.) Add 60 ml 2% ethanolic or methanolic KOH, and fit flask with a West condenser cooled with circulating cold tap water. Reflux gently on steambath for 30 minutes. When refluxing is complete, rinse down inside of condenser with a snail volume of alcohol before removal from flask. Transfer the reflux solution using a small funnel with glass wool plug to a 250 ml separatory funnel, avoiding transfer of any paper material. Rinse paper and flask with three, 40 ml portions of petroleum ether, combining petroleum ether rinses in the separatory funnal. Add 60 ml water to the separatory funnel and shake vigorously for 30 seconds. Drain lower aqueous layer into a second 250 ml separatory funnel. Add 60 ml petroleum ether to the second separatory funnel and hake vigorously for 30 seconds. Discard aqueous layer and combine petroleum ether layers in first separatory funnel. Rinse second separatory funnel with a few small portions of petroleum ether, MGNS 076786 -3- collecting rinses in first separatory funnel. Hash petroleum ether with three, 40 ml portions of distilled water, discarding each wash. Dry petroleum ether through a 25 an x 50 mm column of anhydrous Na2S04, collecting eluate in a Kuderna-Danish concentrator. Rinse separatory funnel and then column with three, about 20 ml portions petroleum ether, collecting rinses. Concentrate combined petroleum ether extract and rinses on steam bath to about 5 ml. Extract is ready for cleanup on Florlsil column. If experience with particular sample types indicates that Florisil column cleanup is not required, proceed to gas chromatographic determination. Note: Adequate extraction of low density paper such as newspaper or tissue paper will require adjustment of either the amount of sample downward from 10 grams or the volume of reflux solution upward from 60 ml. If possible reduce the weight of the sample material below 10 grams to a quantity that is completely covered and wetted by 60 ml of the reflux reagent. If a larger amount of sample (not to exceed lOg) is required, use a volume of reflux reagent to completely cover and wet the sample. Increase in volume of reflux solution over 60 ml must be accompanied by proportional increases in volumes of petroleum ether rinses of sample, water diluent added to the alcoholic reagent in the separatory funnel, and sise of Erlenmeyer flasks and separatory funnels. Cleanup Add lOg of Florisil to 22 mm id chromatographic tube. Settle column of Florisil by gentle tapping of chromatographic tube. Top column with about 1/2" anhydrous Na2S04. Pre-wet column with 20 ml petroleum ether. Place Kuderna-Danish concentrator with volumetric collection vessel under column to receive eluate. Transfer petroleum ether extract to column letting it pass through column at about 5 ml/min. Rinse container with three, 5 ml portions petroleum ether transferring each to column, and rinse walls of chromatographic tube with additional stall portions of petroleum ether. Elute column at about S ml/min with 150 ml of petroleum ether. Concentrate eluate to suitable definite volume in Kuderna-Danish evaporator. If volume less than 5 ml is required, use 2-ball micro Snyder or micro Vigreaux column during final evaporation. Eluate is suitable for analysis by gas chromatography with electron capture detection. Note: Waxes, if present in the extract, can be removed prior to Florisil chromatography by partitioning between petroleum ether end acetonitrile, Pesticide Analytical Manual, Vol. I., 211.14. *CNS 078789 ATTACHMENT XII Gas Chromatographic Determination of PCB The following is taken from changes in AOAC official malti-pesticide residue methodology. Chapter 29.001, made to include PCB in the gas chromatographic determination. To appear in March, 1973, Journal of the AOAC, "Changes in Official Methods of Analysis of the Association of Official Analytical Chemists Made at the Eighty-sixth Annual Meeting, October 9-12, 1972". "Sec. 29.017 Gas Chromatography, introductory par., was revised as follows" "(Applicable to chlorinated pesticides, phosphated pesticides, and polychlorinated biphenyls (PCB) Method is applicable to PCB residues when present alone in sample. If pesticidal or other compds are detected in chromatogram of the PCB residue, other chemical or physical operations must be applied to eliminate or miminise their interference before PCB qu&ntitation.) Inject suitable aliquot (3-8 pi) of coned eluate from Florisil or MgO-Celite column contg amt compd within linear range into gas chromatograph, 29.008, using 10 pi syringe. Tentatively identify residue peaks on basis of retention times. Measure area or ht of residue peak(s) and det. residue amt by comparison to peak area or ht obtained from known amt appropriate ref. material(s). To insure valid measurement of residue quantity, size of peaks from residue and ref. std should be within *25%, Chromatograph ref. material(s) Issradiately after sample. Measure PCB residues by comparing total area or ht of residue peaks to total area or ht of peaks from appropiate Aroclor(s)^ (Monsanto Co., 800 N. Lindbergh Dlvd, St. Louis, M0 63166) ref. meterials. Measure total area or ht response from common baseline under all peaks. Use only those peaks from sample that can be attributed to chlorobiphenyls. These peaks must also be present in chromatogram of ref. material. Mixt. of Aroclors may be required to provide best match of GLC patterns of sample and ref." MCNS 078790 ATTACHMENT II Micro Scale Alkali Treatment for Use in Pesticide Residue Confirmation and Sample Cleanup by Susan J. V. Young and Jkkiiv A. Hukke Divition of Chemical Technology Bureau of Foodt Food end Drug Adminitiration Wathington, l). C. 20204 Procedures involving alkali treatment for dehydrochlorinatlon of certain organochlorine pesticides and saponification of fats have long been employed in pesticide residue analysis. In 1942 Brand and Busse-Sunderman (1), and In 1946 Soloway ct^ al. (2), studied rates of dehydrochlorinatlon of DDT. Mills (3) used refluxing alcoholic KOH In the cleanup of fatty foods for paper chromato graphic detection of alkali-stable organochlorine pesticides. Klein and Watts (4) used alcoholic NaOH to dehydrochlorinatc and j>,'-DDT, j,'-TDE, and Perthane prior to gas chroma tographic separation of the respective olefins. These Investigators called attention to several earlier uses of alkali dehydrochlorinatlon in pesticide residue chemistry. Recent literature contains numerous references to application of this treatment in pesticide residue analyses, including an adaptation for use in a pre-gas chromatographic (GLC) column (5). In spite of the knowledge of this reaction we have observed that it is not fully and effectively utilised by residue laboratories for forming derivatives, gaining Information for identity confirmation, or obtaining better cleanup of troublesome extracts. This is probably because the procedure has not been described in detail for simple micro scale application in multiresidue analysis. The purpose of this work was (1) to arrive at optimum and convenient parameters of the alkali treatment in order to obtain rapid dehydrochlorinatlon resulting in product solutions suitable for analysis by GLC; (2) to obtain complete yield and recovery of olefins from a number of bis(plienyl) chloroethane pesticides; (2) to determine the effect of the treatment on several important pesticide and industrial chemicals; (4) to describe in detail Che procedure Tor routine application in the residue analytical laboratory. METHOD Reagents and Apparatus (a) Potassium hydroxlds - Anhydrous pellets. (b) Ethanol - USP 95X. <c) Hexane - Suitable for uae with electron capture gaa chromatography (Burdick and Jackson Laboratories, Inc. 1953 8. Harvey St., Muskegon, Mich. 49442). 160 lldtii < Rnetrenmeniel CtnuminiUMi * Teileelon. V*L 1, Ne, VS. im SfU**fVerU* New Verk Ur. MCNS 078791 (d) Micro condenser - 19/22 J; K-569250 (Kontes Glass Company, Vineland, N. J. 08360). (e) Concentrator tube - Mills type, 19/22 J with stopper, 10 ml graduated in 0.1 ml up to 1.0 ml; K-570050 (Kontes Glass Company). (f) Alkali dchydrochlorlnatlon reagent - Dissolve 2 g KOH in 100 ml ethanol. (g) Ethanol - water. 1 + 1 - Combine equal parts by volume of distilled water and ethanol. (h) Caa chromatograph - Equipped with electron capture detector and 6* x 4 am id glass column contsining either (1) 10% DC-200 or (2) 1:1 mixture of 15Z QF-1 + 10% DC-200 on 80-100 mesh Chromosorb W(HP). Operating conditions: N2 flow 120 ml/min; temperatures, column and detector 200C. Injector 22SC; concentric design electron capture detector operated at dc voltage to cause 1/2 full scale recorder deflection for 1 ng heptachlor epoxide when full scale deflection is 1 x 10" amp. Procedure Accurately pipet, into a 10 ml Mills tube, 2 ml of a petroleum ether solution of sample extract l6X or 15Z Florisil eluate (6)) containing concentrationa of pesticides suitable for subsequent CLC analysis. Add 1 ml of 2X ethanolic KOH and a few carborundum chips and fit the tube with a micro condenser. (Note: Avoid getting alkali on the ground glass Joint* light greasing of joint with silicone lubricant may prevent sticking. ) With a test tube clamp, hold the tube over an opening in the steam bath in such a manner that gentle boiling occurs. When the volume has been reduced to about 1 ml, insert the tube completely into the steam bath opening and heat vigorously for 15 minutes or until the volume reaches 0.2 ml. Remove tube from the steam. If a precipitate has formed, as is often the case with extracts containing fatty substances, add a few drops of 2Z ethanolic KOil and warm gently in steam with swirling until the precipitate dissolves. After Che solution has cooled slightly, add about 2 ml ethanol-l^O (1+1). Allow solution to reach room temperature and pipet 1 or 2 ml hexane Into tube. Stopper tube with ground gloss, Invert, shake vigorously for about 30 seconds, and allow solvent layer to eeparate sharply. With mlcrolltcr syringe, carefully withdraw aliquot of upper layer for determination by GLC. [Note: Separation of phases should be sharp so that solution withdrawn for CLC analysis will be free from alkali.] Discussion Development of Method Initial experimentation was performed to establish the reaction con ditions which would give complete and rapid dehydrochlorlnatlon of 2,'-DDT, o,j>'-DDT, ,'-TDE, o.jj'-TDE, methoxychlor, and Perthane and which would permit complete recovery of the respective olefins. Work waa dona to determine the effect on olefin formation of fatty substances not removed during sample cleanup and the capacity of the reaction to eliminate fatty substances. 161 MGfcS 0787$2 Several considerations found necessary for practical and reliable use of the alkali treatment have been Incorporated into the method and are briefly discussed. The steam bath was chosen as a source of heat because of its ready availability and convenience. The Hills reaction tube was fitted with a micro condenser to eliminate losses due to volatilization, which often occurred in the absence of the condenser. Both KOH and NaOK have been used to the satis faction of previous Investigators. The more frequent use of KOH by other workers and Its higher solubility In ethanol made it the choice for this work. An alkali concentration of 2X has been widely used, and was found ideal for treatment of aliquots of cleaned-up sample extracts containing quantities of bis(phcnyl) chloroethane pesticides ranging from a few nanogram6 to 100 ug. In order to provide sufficient reflux time and temperature it was necessary that the Initial volume of ethanol be In excess of 0.5 ml. When smaller volumes were used, dehydrochlorinatlon was usually Incomplete. Emulsions often occurred during extraction of the olefin Into hexane after saponification of fatty substances. The uae of ethanol + water (1 + 1) instead of water a6 the diluent resulted in a sharp separation of hexane and aqueous layers. Recoveries of olefins were not adversely affected if the ethanol content was less than about 70X. Less than 30X ethanol did not adequately enhance separation of the two layers. The non-volatllc fatty subatance transferred to acetonitrile by partitioning a petroleum ether solution of butterfat with acetonitrile was used in teats to evsluate Che effects of fatty substances on the reaction. Experiments In which varying volumes of 22 ethanolic KOH were used to saponify 350 mg portions of this butterfat showed that each 1 ml of 22 KOH would saponify about 50 mg of the fat. When the weight of fatty substances exceeded about 50 mg, complete dehydro chlorinatlon of Perthane (40 ug) and mcthoxychlor (4.0 ug) was not obtained. However, j>,j>'-DDT (8.0 ug) was completely dehydrochlorinated In the presence of 100-120 mg of fat. Additional experiments'* tlon showed that complete dehydrochlorinatlon of mcthoxychlor and Perthane did not occur until the fat was completely saponified; these were the bis(phenyl) chloroethancs most resistent to dehydrochlorinatlon. Quantities of Perthane and ,'-DDT up to 100 Ug in the presence of not more than 50 mg butterfat were readily dehydrochlorlnatcd with 1 si of 22 KOH at steam bath temperature; dehydrochlorinatlon of larger amounts of pesticide was not attempted. Hexane, because of Its higher boiling point and greater ease of drawing Into a microsyringe, was used instead of petroleum ether, to extract the olefin after reaction In order to avoid possible errors in quanta la Lion. Effect on Selected Chemicals The dehydrohalogenatlon reaction, as described under "Method", was applied to ,*-I>DT (0.8 Ug). o,'-DDT (0.8 Ug), ,'-TDE (2.0 Ug). o,'-TDE (0.4 ug). nethoxychlor (4.0 ug), and Perthane (40 ug) Quantities shown in parentheses were chosen for ease in CLC determination. The pesticides were treated individually In petroleta ether, in 62 ethyl ether/petroleum ether Florlsll eluatea (6) containing the equivalent of 6 g of kale, and In 162 HONS 078793 petroleum ether containing 30-60 mg of fatty substances extracted from butter by partitioning (6) between petroleum other and acetonitrile. Gas chromatography with electron capture detection, operated as described under "Method", was used for all determinations. Each pesticide was completely altered In each of the solution types, i.e., none of the parent compound remained after treatment as described under "Method". Percent recoveries of the respective olefins were calculated according to the following equation: wt. olefin compound determined by CLC x wt. parent compound represented in aliquot to Gl.C wt. parent compound/mol. wt. wt. olefin compound/mol. wt. * Recoveries of olefins approximated 1002 and ranged from 862 for j>,*-DDK and o^jj'-TDE olefin in petroleum ether to 1102 for j,p'-DDK in the extract from butter. Two olefin derivatives, the els and trans isomers, are formed from ,j>'-TDE (7). These have identical retention times on the two CLC columns used in this work and were quantitated as a single compound. Several additional common organochlorinc pesticides and polychlori nated biphenyls (PCR) were subjected to the described nlkali treatment. All tests were made with petroleum ether solutions of the chemical under study. The quantity of each chemical was chosen (or ease of determination by GLC and is given in parentheses. Polychlorinated biphenyls ranging from 21 to 602 average chlorine content were stable to this treatment. Complete recoveries were obtained for the commercial PCD mixtures, Aroclors 1221 (16 ug), 1232 (16 yg), 1242 (16 ug), 1254 (8 ug), aud 1260 (8 ug) Recoveries of unchanged aldrin (0.4 Ug), dieldrin (0.4 ug), and endrin (0.4 ug) ranged from 70 to 902. No alteration products were detected. Hcptochlor (0.4 Ug) and heptachlor epoxide (.0.4 ug) were markedly affected; recoveries of the original compound ranged from 30 to 502. Minor Gl.C peaks were observed on the 102 DC-200 column at retention times relative to aldrin of 1.63 after treatment of heptachlor epoxide and 0.59 and 0.93 after treatment of heptachlor. The nlkali treatment completely eliminated lindane (0.2 Ug) and the alpha (0.2 Ug), beta (0.2 ug), and delta (0.2 ug) Isomers of BHC. Following the reaction, only small early eluting gas chromatographic peaks, presumably from trichlorobenzcnes, were observed. About 402 of mlrex (4.0 Mg) remained unchanged after reaction; sometimes a minor GLC peak appeared at a retention time relative to aldrin of 1.83 on the 102 DC-200 column. 163 MGNS 078794 Endoaulfen I and II, treated separately, were completely eliminated. Each isomer gave a single alteration product with retention time relative to aldrin of 1.82 on the 10Z DC-200 column and 2.23 on the 1:1 10Z DC-200/15X QF-1 column. The peak height of the alteration product was approximately one-tenth the peak height of the parent compound. A structure for this derivative has been proposed (8). Endosulfan sulfate also was completely eliminated. Two alteration products were obtained with retention times relative to aldrin of 0.28 and 0.38 on the 10Z DC-200 column. Dlcofol (1.0 Mg) was completely eliminated but only 65Z of the major alteration product, 4,4*~dichlorobenzophenone, was recovered. A minor peak was observed in the chromatogram at a retention time relative to aldrin of 1.71 on the 10Z DC-200 column. The 4,4'- dlchlorobenzophenone (2.0 Mg) was not affected by treatment with alkali. . Hie products resulting from alkali treatment of toxaphene (10.0 Mg) gave a multicomponent chromatogram but consisting of components with earlier retention times than toxaphene itself. The electron capture CLC responses to sulfur (20 Mg), frequently encountered in residue analysis at retention times relative to aldrin of 0.23, 0.55, and 1.13 on the 10Z DC-200 column, were eliminated by the alkali treatment. Application of Method The moat obvious use of the alkali treatment la to form the olefins of bls(phenyl) chloroethane pesticides for confirmation of residue identity. The complete yield and recovery of the olefin derivative makes possible quantitative confirmation of e residue of the parent pesticide. For example, a residue of ,'-DDT can be quantitated before alkali treatment and verified by quantitation as ,*-DDE after treatment. In addition the CLC retention time region of the reacted compound can be examined for presence of peaks from unrcacted and presumably interfering substances. We have found the alkali treatment especially useful In connection with the real or suspected presence of residues of PCB. In this case the characteristic olefin derivatives of *~DDT, o,*--DDT, and ,'-TDE can be formed and the CLC retention time region underlying the parent compounds can be examined. The stability of PCB to alkali, with no change in the CLC pattern, is e characteristic which can be readily utilized in confirmation of the identity of this complex residue. The high recovery of unreacted dleldrin, endrln, and aldrin following alkali treatment likewise can be of value In the confirmation of identity of these pesticides. 164 MGNS 078795 TABLE 1 Compounds Treated with Alkali According to the Described Procedure Compound Approximate Amount Altered, X Major Alteration Products Detectable tty GLC Approximate Amount of Parent Compound Changed to Alteration Product, l p,p'-DDT o,p'-DDT p,p'-TDE o,p`-TDE 100 100 100 100 Perthane 100 methoxychlor 100 dlcofol 100 4,41 -dichlorobenzophenone 0 lindane 100 0,0,6 isomers of 3HC 100 endosulfan 1 100 endosulfan 11 100 endosulfan sulfate 100 alrex 60 heptachlor 50-70 heptachlor epoxide 50-70 aldrln 10-30 dieldrln 10-30 endrin 10-30 toxsphene apparently greatly altered p,p*-DDE o,p'-DDE p,p'-rDE olefin els o,p'-TDE olefin trana o,p'-TDE olefin Perthane olefin methoxychlor olefin 4,4'-dichlorobenzophenone -- presumably trichlorobenzenes presumably trichlorobenzenes 1.82 DC-20Olr 2.23 nlxet 1.82 DC-200i! 2.23 nixed! 0.28, 0.38 DC-2001 1.83 DC-200* 0.59, 0.93 DC-200! 1.63 DC-2001 ------ ' -- -- substances with earlier RRTA than toxaphene 100 100 100 100 100 100 65 -- -- -- -- ... -- ... -- ... ... HONS 078796 Compound TABLE 1 (continued) Approximate Amount Altered, X Major Alteration Products Detectable by GLC Approximate Amount of Parent Compound Changed to Alteration Product, X polychlorinated biphenyls: Arochlors 1221, 1232, 1242, 1254, and 1260 sulfur: 0.23, 0.55, . 1.13 DC-200" 0 100 -- -- -- Retention time relative to aldrin on the 10% DC-200 column, described under "Reagents and . Apparatus (h)M. -- Structure elucidated by Greve and Wit (8). Retention time relative to aldrin on the 1:1 QF-1 + 10X DC-200 column, described under "Reagents ar.d Apparatus (h)". HONS 0 7 8 7 9 7 Cleaned-up extracts cf some samples may contain non-pestlcldal substances which give rise to electron capture response. Other extracts may contain fatty substances, not removed by the clean up, which can prohibit application of some tests, e.g., thin layer chromatography. This is particularly true of the 15X ethyl ether/petroleum ether Florlsll column eluate (6) for non-fatty samples such as carrots and fatty samples such as some fish. Electron capturing substances present In carrots must be eliminated before determination of dleldrln and/or endrln residues. Treatment vlth alkali serves veil for this purpose. Extracts of fatty samples may require treatment to eliminate both electron capturing substances and non-volatile fatty substances. In many instances thin layer chromatography or mlcrocoulometrlc GLC cannot be accomplished prior to alkali treatment. Electron capture responses to sulfur, often a source of annoyance to the residue chemist, are also eliminated by this treatment. These common uses of the alkali treatment serve to illustrate Its value to the residue chemist. The directions for laboratory application outlined here should enhance the use of this procedure of long standing. . References 1. BRAND, K. and BUSSE-SUNDERMAN, A., Berlchte, 75 B 1819 (1942). 2. SOLOWAY, S. B., SCHECHTER, M. S., and JONES, H. A., Soap and Sanitary Chemicals, 1946 Blue Book, 16th Ed., 215 (1946). 3. HILLS, P. A., J. Ass. Offic. Anal. Chcm. 42, 734-740 (1959). 4. KLEIN, A. K. and WATTS, J. 0., J. Ass. Offic. Anal. Chcm. 47, 311-316 (1964). 5. MILLER, G. A. and WELLS, C. E., J. Ass. Offic. Anal. Chem. 52, 548-553 (1969). 6. Pesticide Analytical Manual, Vol. 1. Pood and Drug Administration, Washington, D. C., 2nd Ed., 1968; Revised July 1969, July 1970, and April 1971. 7. KRAUSE, R. T., Private Communication, Food and Drug Administration, Washington, D. C., May 1970. 8. CREVE, P. A. and WIT, S. H.. J. Aer. Pood Chem. 19, 372-374 (1971). 167 HONS 078798 Reprinted from ATTACHMENT IV Journal of Chromatography Blacvier Publishing Company. Amsterdam Printed in The Netherlands CHROM.6243 GAS CHROMATOGRAPHIC DATA FOR POLYCHLORINATED BIPHENYL COMPONENTS IN SIX AROCLORS* JUDITH A. ARMOUR Mvition of Chemical Technology, Food and Drug Administration, Washington, D.C. 00004 (U.S.A.) (First received April nth, 197a; revised manuscript received July 5th, 1972) SUMMARY Illustrations of gas chromatographic curves, relative retention times, and re sponse data from 10% DC-200 and 1:1 15% QF-1/10% DC-200 on 80-100 mesh Chromosorb W HP columns with electron capture detection are compiled for six Aroclors* Aroclors* are commercial mixtures of polychlorinated biphenyls com monly used as analytical refcrcnocs for polychlorinated biphenyl residue deter mination. INTRODUCTION The industrial chemicals known as polychlorinated biphenyls {PCB), which have become widespread environmental contaminants1-', are generally determined by essentially the same techniques used for organochlorine pesticides* and may act as interferences in the gas-liquid chromatographic (GLC) determination of pesticide residues. Because there is no standard PCB and individual chlorinated biphenyl compounds arc not readily available, it is necessary to rely on Aroclors* as analytical references for PCB residue determinations. Aroclor* is tl*c general tradename for commercial mixtures of PCB manufac tured in the United States by Monsanto Company. Each Aroclor is a mixture of chlorinated bipltcnyls (1200 series), chlorinated terphenyls (5400 scries) or a combina tion of chlorinated biphenyls and terphenyls (4400 series). The last two digits of the identifying number indicate tlie percentage weight of chlorine, eg,, Aroclors 1254 and 1260 are biphenyls containing 54 and 60% chlorine, respectively*. GLC patterns of PCB residues in environmental samples have generally resembled Aroclors 1234 and 1260. although the possibility exists that residues may derive from any ofthe Aroclors. The GLC retention times, relative peak sizes, peak shapes, and overall peak pattern of PCB residues must be carefully, compared to the corresponding data for the Aroclors in order to determine the Aroclor(s) that most closely resemble the residue. Because the magnitude of total area varies significantly for the same weight of different Aroclors, the quantitative value determined for the PCB residue depends J. Chrommtogr., 71 (1972} 273-282 MGNS 078799 276 J. A. ARMOUR upon which Aroclor(s) is chosen for quantitation reference. The interpretation and evaluation of GLC chromatograms in PCB determinations is augmented by ready access to relative retention times, response data, and reference chromatograms of the various Aroclors. Data for these GLC characteristics of six Aroclors, obtained by using two GLC columns regularly employed in our laboratories*, are presented here. Data are not presented for Aroclors 1232. 1268, 5442, 3460, and 4465. Aroclor 1232 has been commercially prepared7 by blending appropriate quantities of Aroclors 1221 and 1242 to obtain 32% total chlorine; chromatograms of material obtained from different lots revealed substantial differences between sonic lots. Aroclor 1268 was not available at the time of this work. GLC at the dcscrilied conditions of Aroclors 5442 and 5460 (chlorinated tcrphenyls) and 4465 (mixture of PCB and chlorinated tcrphcnyls) resulted in multicomponent chromatograms with peaks emerging at retention times extending to several hours; several hundred nanograms were required for detection of latc-cluting constituents. These GLC parameters are considered unsuitable for detec tion and measurement of the polychlorinated tcrphcnyls. A system utilizing parallel columns with liquid phases of 2% OV-joi and 3% Dexsil 300 operated at 240 has been devised for GLC of both the polychlorinated terphenyls and PCB*. EXPERIMENTAL . GLC data were obtained with a gas chromatograph equipped with an electron capture detector and 4-mm x 6-ft. glass columns, packed both with 10% DC-200 on 8o-too mesh Chromosorb W HP and a 1:1 mixture of 25% QF-i plus 10% DC-100 on 80-100 mesh Chromosorb W HP*. Operating conditions: nitrogen, 120 ml/min; column and detector temperature, 200; injection temperature, 223. The concentric design electron capture detector was operated at a d.c. voltage to produce half full scale recorder deflection for 1 ng hcptachlor epoxide when full scale deflection is X X 10"* A. Recorder speed was } in./min. Different concentrations of Aroclors were injected at the conditions given to determine the quantity necessary for approximately half full scale recorder response or enough response to illustrate all the characteristic constituents of a particular Aroclor. Retention times were measured in millimeters from the leading edge of the response to the solvent and reported relative to the retention time of the pesticide aldrin. These conditions and manner of reporting GLC data for Aroclors were chosen to conform to GLC data compiled in the Food and Drug Administration Pesticide Analytical Manual* for a large number of pesticides. ESULTS The following informatioi) has been compiled in the tables and figures to be a source of reference and comparison for the GLC behavior of PCB: retention times, response data and illustrations of chromatograms for six Aroclors from two GLC columns. Table I lists the quantities necessary for approximately half full scale J. Ckrommieg*., ft (197a! 373-382 HONS 078800 GC DATA FOR POLYCHLORINATED BIPHENYLS IN AROCLORS 277 TABLE I QUANTITIES OF AROCLORS NECESSARY FOR APPROXIMATELY HALF PULL SCALE RECORDER RESPONSE* Aroclor Sonogromt for if* f.t.r. DC-moo* QF'ijDC-too* ` 1211 So 60 1141 40 40 1248 40 jo 1254 30 JO 1260 to SO 126a 20 . 20 * Quantities of Aroclor mixtures to produce approximately half full wale recorder response (1/2 f.s.r.) for major Aroclor components or sufficient response to detect all the characteristic Aroclor constituents. * GLC column and detector conditions are given under experimental. TABLE II GIX RETENTION TIME DATA POE SIX AROCLORS Support material: Chromosorb W HP. 80-100 mesh; stationary phase: 10% DC-200 (6ft. x 4 mm 1-I>- column); carrier gas: nitrogen, 120 ml/min; temperature: 200*, detector: electron cap ture (tritium); sample site: quantities necessary for approximately half full scale res)ionse (see Teble 1); data given in: retention sequence relative to airlrin from solvent peak. Aroclor Aroclor ton i>4* Aroclor 1*48 Aroclor iijf Aroclor j*6o Aroclor i*6a o.jt o.j6 o.J9 0.32 O.59 0.64 0.69 0-75 0.88 0.99 I.J7 I.41 I.32 I.T* 1.86 i.ot t.22 2.63 3. to 039 0.31 057 0.67 0.71 0.86 0.96 i.oj 1.22 '39 149 '74 1.8} 2.90 t.56 0.5I O.37 . O.67 O.fto O.83 O.96 I.OJ i.aj '39 '49 '74 1.84 i.ao 2.54 1*4 0.87 0.98 1.05 1.17 1.59 I.78 1.88 2.20 2.6J 3.08 3.60 4.10 3 4 90 3.I0 1.28 1.50 1.86 2.07 9.21 I.63 2.84 JO* 3-30 4.10 4 9* 380 6.30 7.80 9.10 1.26 I.30 1.85 i.7 2.22 2.6l 2.82 3.06 3 30 4.10 490 3*o 6.40 6.60 7.80 9.10 /. Ckromoiofr., 72 (1972) 273-282 HONS 078801 276 }. A. ARMOUR recorder response or for enough response to illustrate all the characteristic constituents of a particular Aroclor. Tables II and III give the retention times relative to aldrin for all the peaks present in six different Aroclors. These tables arc arranged to readily show similarity and differences in the GLC elution pattern of the various Aroclors. Peaks with similar relative retention times in the different Aroclors arc not necessarily responses to the same compound. Figs. 1-3 arc gas chromatograms of six Aroclors from the 10% DC-200 column; Figs. 4-6 are gas chromatograms of six Aroclors from the I :i 15% QF-1/10% DC-200 column at the specified conditions. The GLC data for PCB presented here should lx* a useful reference for evalua tion and interpretation of GLC chromatograms for PCB residue determinations. TABLE III CIX KKTBNTION TIMS DATA FOR SIX AROCLORS Support material: Chromosorb W HP. So-100 mesh; stationary phase: 1 :i 15% QF-1/10% JX: 300 (6 ft. x 4 mm I P column); carrier gas; nitrogen. 120 ml/min; temperature: ?ooa; detector: electron capture (tritium); sample site: quantities necessary for approximately half full scale recorder response (see Table i): data given in: retention sequence relative to aldrin from solvent peak. Aroclor !/ 0.30 0.39 O.36 0.39 o.J3 o.J7 0.71 0.78 0.88 1.03 I.IO I-3I * 53 t.8a 1.96 1.08 3.26 13.)648 .*4 J* Aroclor 1*4* Aroclor 1048 041 . 0-33 o-33 0.61 0.61 0.73 0.72 0.82 0.90 1.03 1.09 1 34 1.5a 1.8a 0.82 0.90 1.02 1.09 >34 1.3* 1.82 1.97 *97 1.36 3.80 3*4 1.J6 3.8o 3*4 Aroclor **54 0.87 1.02 I 31 1.5a 1.82 1.96 * 34 2.68 3.80 3'* 33 3 90 4*o 300 Aroclor l6o Aroclor 1362 '3* l 31 * 53 53 1.84 t.86 3.08 3.14 2.26 2.24 3.66 2.66 3.88 3.88 J.22 J.22 3 30 3 5 3-90 39 4.30 4.20 J.OO J.OO 6.10 6.10 6.jo 6.50 7.40 8.00 9 30 II 9 J. CkrommiPft ., 72 (1972) 275-283 MOMS 078802 GC DATA VOH POLYCHLORINATED BIPHENYLS IN AROCLORS 279 Time (min) Fig. 1. GLC separation on 10% DC-200 column of 120 ng Aroclor 1221. GLC condition* ere given under sxprrinsntal. Fig. 2. GLC separation on o% DC-aoo column of (A) 50 ng Aroclor 1242 and (D) 30 ng Aroclor 1248. GLC condition* are given under ixpcrimihtal. MGNS 078803 280 J. A. ARMOUR Aiortn p,p'-DDT 6 a*'' '16 e '20' '' W '30 ' Aiortn ftp', dpi Time (mm) ^ ao '' 45 m m Fig. 3. CI.C MporatioD on 10% DC*too column of (A) jt ng Aroclor 1254. (B) to ng Aroclor 1260 and (C) tong Aroclor Jt6t. GLC condition* are given under axrtaiuauTAL. Time Imn) Fig. 4. Gaa chromatographic aeparation on i:t 15% QF-i/io% DC-too erf ito ng Aroclor ttti. GLC condition* arc given uoder nxenamiMTAt. /. Chromtipfr., 72 (1972) 275-282 HONS 078804 Fig. J. Cm chromatographic separation on t:l 15% QF-l/io% DC-200 of (A) 50 ng Aroclor 1242 and (11) 50 ng Aroclor 1248. CLC conditions arc given under experimental. C 0 5 10 * * *0 25 >0 40 as ao A*ori p,a'-0O1 Fig. 6. Gas chromatographic separation on 11 15% QF-1/10% DC-joo of (A) 33 ng Aroclor tsjt. (D) <0 ng Aroclor 1260. and (C) 20 ng Aroclor 1262. CLC conditions are given under expuuimb ntal. HONS 078805 282 J. A, ARMOUH REFERENCES l D. D. Pbakau. AND J. L. Line**, Biatcienca, 20 (1970) 958. 3 L. M. Kr.YNOi.nA. Hesidut Htv., 34 (1970) *7j It W. Kirkmboucii, P. Rkichr and H. S. Olcott. Bull. Environ. Coniam. Toxicol.. 4 (1969) 19a. 4 J. A. Armour and J. A. Burkk. J. Ass. Offit. Anal. Chem., 53 (1970} 761 3 Atoclor Plasticisers. Technical Bulletin O/PL-J06, Monsanto Co.. St. Louis, Mo. 6 Pesticide Analytical Manual, Vol. I, Food and Drug Administration. Washington. DC., 196H, 7 Monsanto Chemical Company, private communication. November. 1971. 9 W. W. Wixncx*. U S. Food and Drug Administration, private communication. January, 1971. 9 ). Burkk and W. Houwade, J. Ass. Offic. Anal. Chem., 49 (1966) 374. J. Chromalvgr,, 73 (197*) 175-382 HOMS 078806 ATTACHMENT V Quantitative Perchlorination of Polychlorinated Diphenyls as a Method for Confirmatory Residue Measurement and Identification By J. A. APMOUR (Division of Chemical Technology, U. S. Food and Drug Administration, Washington, D. C. 20204) To be published: Journal Association Official Analytical Chemists, July, 1973 Abstract The perchlorination procedure for derivatization of PCB described by Berg, Diosady, and Rees has been modified to achieve a micr:> scale quantitative conversion (greater than 90%) of corrx.iercial PCB preparations, (Aroclorsff), to decachlorobiphenyl. Cleaned up sample extracts containing PCB residues (1 pg~20jjg) are reacted with antimony pentachloride in the proscree of chloroform to^form dccuchlerobiphonyl. This procedure converts a multicomponent mixture to a single derivative detectable by EC-GLC thus providing an easy method for quantitating and identifying PCB retidues and at the Same time increasing the sensitivity of Ictection. The usefulness of the perchlorination procedure is demonstrated by comparing results for environmentally contaminated samples quantitated by measuring the total area of the KC-GLC response for the residue against the Aroclor it most closely resembles to results obtained by measuring the single peak of the decachlorobiphenyl derivative and expressing the results in terms of tho particular Aroclor. MCMS 073607 Quantitative Pcrchlorinotion of Polychlorinated Diphenyls as a Method for Confirmatory Residue Measurement and Identification Dy J. A. ARMOUR (Division of Chemical Technology, U. S. Food and Drug Administration, Washington, D. C. 20204) Introduction Analytical methods normally employed for the extraction, cleanup, and detection of polychlorinated biphenyl (PCD) (1-3) residues are generally 'r those used for organochlorine pesticides (4). Quantitative values are usually obtained by measuring the total area of a PCB residue response as shown on a gas chromatographic tracing using an electron capture or microcoulometric detector and comparing it with the total area of a similarly obtained response of the commercial PCD preparation (Arocloi^ (5) it most closely resembles (6). This has proved to be a practical procedure for quantitation, however, it is limited because of leek of sensitivity, the multicomponent nature of PCB residues, alterations in residue pattern due to metabolic and environmental changes, and the need to rely on commercial Aroclors as reference materials* Procedures to convert all PCB components to a single derivative, e.g. biphenyl or decachlorobiphenyl (DCB), that is indicative of the total PCB residue and could be used for quantitative purposes have previously been reported (7-B). In this study, the perchlorination procedure described by Berg, Diosady, and Rees (7) has been modified to achieve complete HONS 078808 conversion on a microscale of all PCB components in a.cleaned up sample extract to decachlorobiphcnyl, thus providing a qualitative and quanti tative confirmatory procedure for PCB determination. A quantitative value obtained by measuring the single GLC peak of a DCB derivative against a DCB standard of known purity reinforces the residue value achieved by the measurement of a multicomponent PCB residue. It also greatly increases the sensitivity with which PCB can be detected and measured. Measuring the single GLC response for DCB will also minimize necessary analytical judgments involved in the physical measurement of the GLC curve of a multicomponent residue (i.e. position of baseline and method of integration) and in the discrimination between PCB and non PCB components. Methodology Reagents Antimony pentachloride - Allied Chemical Reagent Code 1365. Sodium Sulfate - anhydrous, granular; it may be necessary to wash with acetone and ethyl ether to remove electron capturing substances. 11C1 - 6N solution (1+1 dilution of concentrated HC1 in water). Sodium Bicarbonate - 1Q\ weight/volume aqueous solution. Solvents - Hexane, chloroform, and methanol suitable for use in pesticide residue analysis; distilled-in-glass product is satisfactory. (Available from Burdick and Jackson Laboratories Inc., 1953 S. Harvey St., Muskegon, Mich. 49442) MGNS 078809 ~3- Apparatus (a) Vacuum hydrolysis tube - 150 mm X 10 mm o.d. with No. 4 Teflon \alvo (Kontes Glass Co. K-G96860-0004) or Carius pyrex combustion tube 200 mm X 8 mm i.d. X 10 mm o.d. (Corning 8640). (b) Silicone oil bath and heating element - Capable of maintaining temperature at 165-175C. (c) Kuderna-Danish evaporative concentrator - With Snyder column and collection tube, 500 ml capacity (Kontes Glass Co. K5470000, or equivalent). (d) Micro-Snyder column - g 19/22 column size 2-19 (Kontes Glass Co. K569001, or equivalent). (e) Gas chromatograph - Equipped with concentric design electron capture detector-operated at a do voltage to produce 1/2 full scale recorder deflection for 1 ng decachiorobiphcnyl when full scale deflection is 1 X 10"9 amps, and 6' X 4 mi i.d. glass column of either (1) 1% OV-101 on 100-120 mesh Gas Chrom Q (9) Gas flow - 120 ml/min N2 Column temperature - 220c Injector temperature - 230C Detector temperature - 200c (2) 3% Dexsil 300 Dn 100-120 mesh Gas Chrom Q 19) Gas flow - 60 ml/min N.. Column temperature - 240C Injector temperature - 250C . Detector temperature - 200c 078810 mqns Perch] orinatin Procedure The sample to be pcrchlorinnted should bo extracted and cleaned up by procedures (such as the FDA multirecidue pesticide procedure (10)) leaving the residues in solvents that can be selectively evaporated from chloroform (6t ethyl ethcr/petrolcuro ether from Florisil or petroleum .ether fraction from silicic acid). Transfer a 1 to 2 ml volume of cleaned up extract containing 1 to 20 pg PCB residue to a vacuum hydrolysis tube (a), (Cari r; tube may bo substituted). Add several drops chloroform, 1-2,20 mesh ca>borundum chips, and reduce volume to 0.1 ml by carefully heating tube in a steambath. Allow tube to cool to room temperature, add 2 ml chloroform, 1-2 carborundum chips, and reduce volume to 0.1 ml on a steambath. Repeat the addition of chloroform, concentrate to 0.1 ml, jind cool to rocm. tampereture. Working in * wol\ ventilated hood, carefully add 0.2 ml antimony pentachlc^ide to tube. Immediately seal tube tightly to ensure a closed system reaction. (Note: it may be necessary to cool Teflon valves in ice before fitting into vacuum hydrolysis tube. The narrowed bottom of the valve should fit flush against the constriction in the glass when sealed. Carius tubes should be sealed in an oxygen flame). Immerse tube to a depth of 2 to 3 inches in an oil bath heated to 165-175C and react overnight (about 15 hours). Remove tube from bath and cool to room temperature. In a hood, and while pointing the venting tide arm of vacuum hydrolysis tube away from face, open by slowly unscrewing the valve and pulling it out of the tube. (Carius tube should be scored with a file and snapped open in a hood at MCNS 078811 -5- arms length away from face; use extreme precaution since there is < rapid release of pressure and sometimes- splintered glass). Slowly add 1 ml 6N HC1 to reaction mixture, tap tube lightly to mix, and quantitatively transfer mixture to 30 ml separatory funnel rinsing with several small portions of HC1, using a total volume of 5 ml 6N HC1. (Note: it may bo noccssary to rock tube back and forth or tap gently in order to drain). Rinse reaction tube with several small portions of hexane using a total volume of 15 ml hexane and quantitatively transfer rinsings to the 30 ml separatory funnel containing the HC1. Shake funnel vigorously for 1 minute; allow layers to separate. Drain the lower HC1 layer into a second 30 ml separatory funnel containing 15 ml hexane, and shake one minute. Drain the HC1 layer into a third separatory funnel containing smother 15 ml hexane and repeat extraction. Discard HC1 layer and combine the three hexane extracts in a 125 ml separatory funnel. Wash hexane extract successively with two 20 ml portions HjC, one 20 ml volume 10% NaHCOj solution, followed by two additional 20 ml portions H2O. Discard all washes. Dry the waihed hexane extract by passing through a 2 inch column of anhydrous sodium sulfate and rinse column with 100 ml hpxanc, collecting hexane extract and rinse in a Kuderna-Danish concentrator. Add a few drops of methanol and concentrate on steambath to about 3 ml. Separate the volumetric receiver from concentrator, attach a micro-Snyder column to receiver and concentrate to a final volume of less than 0.5 ml to remove traces of chloroform. Dilute to a suitable definite volume for GLC determination. Perform GLC determination and calculations as described under^Discussion." M0ft5 C7flfll2 -6- Discussion Berg, Diosady and Rees' microscale porchlorinati.on procedure was evaluated to determine its utility as a routine laboratory procedure for confirmatory PCW quantitation. Parameters for quantitative extraction of DCB from the reaction mixture were not clearly defined by Berg and needed to be established prior to testing the procedure for reproduci bility. Even after we developed a method of extraction that would recover over 95% of DCB standard from the reaction mixture, pcrchlorinatlon using Berg's reaction conditions resulted in 90-100% conversion of Aroclor 1254 to DCB but only 30-70% conversion of Aroclor 1242. Conditions contributing to inconsistency in behavior between Aroclor 1242 and Aroclor 1254 needed to be determined and modifications made to achieve -conversion of a Li P.CB component in the various Aroclors to DCB. Perchlorination: The perchlorinat'on procedure was designed for use following extraction, cleanup, ar.cJii.ary (separation), and detection procedures used in multipesticidc residue methodology. In the Berg ct. al. procedure, cleaned up extracts containing PCB were evaporated to drynens before reaction with antimony pentachloride. Tha observed non reproducible conversion of Aroclor 1242 to DCD with the original procedure is attributed to volatilisation during evaporation to dryness cf the lower molecular weight PCB components present in Aroclors with less than 54% chlorine substitution. To reduce the loss, evaporation is discontinued while a small amount of solvent (0.1 ml) still remains. However, this limits the types of solvents which can be used since they may interfere during HONS 078613 the perchlorination step. It was found that solvents with more than one carbon atom reacted with SbCl^ exothermically to form a solid black product. Chloroform as the solvent, however, minimized volatility, reacted favorably at the given conditions, and permitted selective evaporation of all solvents used in cleanup and separation procedures. Perchlorination is accomplished in a sealed reaction tube at elevated temperature and pressure. Increased pressure produced by the presence of chloroform vapors increased the hazards of handling the Carius tubes recommended for use by Berg et. al. In place of the Carius tube that required sealing in an oxygen flame and careful opening, a reaction tube with the same volume specifications, tight Teflon sealing valve, and ver.ting side arm is recommended for use (see Figure 1). Parameters for extraction of DfT, from the roncti.on mixture were developed to completely reco/er (over 95%) DCB standard. Traces of chloroform present in the extract need to be removed before EC-GLC dotcruination. This can be done by idding methanol, which forms an azeotrope with chloroform, and evaporating to a small volume before diluting. The resulting extract is sufficiently clean for electron capture GLC determination of PCD. In experiments designed to determine the feasibility of a shorter reaction time, iron was tested as a catalyst. One microgram Aroclor 1242 samples were reacted and extracted as described for overnight conditions except that two milligram iron powder were added after the addition of antimony pentachloride, the tube sealed, and the sample reacted for 4 hour and 6 hour periods. Results arc discussed under "Recoveries." MQNS 0788X4 8~ Ity-products that would interfere with quantitative derivatizatio . v;re not evident in our perchlorination experiments/ hov;evor, Stalling Ul) hAs found that a brominated by-product is formed v/hen the antimony pentachloride is contaminated with bromine. Care should be taken to avoid use of contaminated SbClj. GLC systems suggested for.DCB determination are those originally developed for the detection of polychlorinated terphenyls (9). At GLC conditions given under "Methodology"/ DCB elutes in 3-4 minutes on the 1% OV-101 column and in 12 minutes on the 3* Dexsil 300 column. These fast eluting systems produce increased GLC sensitivity to allow easy detection and quantitation of as little as 0.2 ng DCB. Quantitation; Although the perchlorination procedure can have practical applications in PCR quantitation, it is not meant to completely replace procedures normally used for this purpose. The analyst should still be aware of the identity of the contaminating Aroclor(s), the preserce ot other residues which could interfere, and any alteration in Aroclor pattern which may be due to metabolism and/or environmental exposure. This information may be useful in tracing the source of contamination and may have toxicological significance. Some laboratories may wish to express residues in terms of parts per million DCB in order to establish a uniformity in their reporting. However, when the procedure is used for quantitative confirmation, DCB is expressed in terms of a specific Aroclor by using a factor for mathematical conversion. The factors used for converting DCB to the equivalent concentration of a MCNS 078815 --9 -- specific Aroclor are derived by assuming the reaction to proceed SbCl5 ------ > Cl ex ci ci ci Cl Cl Cl C) folJ ows: where n number of chlorines is the approximate whole number of chlorines calculated from percent chlorine substitution for a specific Aroclor (see Table l'f. The approximate whole number of chlorines in a specific Aroclor was chosen for calculations, nlnce Aroclors are commercial preparations and the actual percent chlorine may vary from the theore tical for each lot. The factor for each Aroclor (See Tabic 1) is the ratio of amount Aroclor necessary to yield one unit of DCB: X * factor for expressing DCB moxecular wt. Aroclor X raoitcular wt. DCB (499) a specific Aroclor Calculations for measuring PCI* residues by glc based on the DCB derivative formed and converting mathematically to express the residue in terms of a specific Aroclor are: DCB peak height sample X Nanograms of standard injected * Nanogramr. DC!) in DCB peak height Std sample injection Nanogram Nanograins DCB in sample injection x factor for specific Aroclor (X) = Aroclor sample i jection Nanograms Aroclor in sample injection wt. sample Injected 'm9) " PPra Aroclor in sample HONS 078816 -10- Rccovcrion: To determine the percent conversion of specific Aroclors to DCB, a series of one microgram quantities of six different Aroclors were reacted at the given overnight conditions and extracted as described. The 3% OV-101 column was used for the gas chromatographic determinations. Results are given in Table 2. The method demonstrated good reproducibility for quantitative conversion of the six Aroclors to DCD with results ranging from 87-105% and an average recovery of 97%. In the experiments with shorter reaction times, 10 trials with 4 hour * reactions using Aroclor 1242 gave a wide range of results although the average conversion to DCB was 90%. Trials with 6 hour reaction times gave results falling in a much narrower range and averaging 102% conversion. Results from these and experiments using the six Arocloru at 6 hour conditions arc .given .'n Table 3. The prrchJori.n jtion in quantitative (99% average conversion for six Aroclors) and reproducible (range 03-1)0''..) whim reacted for 6 hours with iron catylst but offers little advantage over the convenient overnight conditions. In order to determine the behavior of the pcrchlorinalion procedure in the presence of extracts of fatty samples, throe gram samples of chicken fat and corn oil were extracted by FDA multiposticide residue methodology (10) The 6% ethyl ether/petroleum ether fractions from Florisil cleanup were fortified with Aroclor 1242 at the 6.7 ppm level. Three aliquots of the Cleaned up chicken fat each equivalent to 0.15 gram of fat and two samples Of the cleaned up com oil each equivalent to 3 grams ware pcrchlorinafcd MCNS 07881? -11- at overnight conditions with average recoveries of 107% and 96% respectively. These results show that the method can tolerate cleaned up extracts of up to 3 gram samples of fat and can handle 1 py-20 Ug quantities of PC). Appl j cat i on Samples of fresli chub, fresh sturgeon, and eggs environmentally contawimiked with PCU, and chicken fat fortified with PCS were extracted and cleaned up by PDA multipcsticide residue methodology (10). Where necessary, PCB were separated from pesticides by chromatography on silicic acid. The PCB residues were quantitated on electron capture CLC with a lOt DC-200 column (10,12) by comparing the total area of the residue with total area of the Aroclor reference with most similar GLC pattern. Aliquots of the 6% ethyl ether/petroleum ether Florisil eluate equivalent to 3 grams chicken fat, 0.2 grams sturgeon fat, and 0.2 grams egg were perchlorinatcd for qualitative and quantitative confirmation. The residue level reported for sach sample after perchlorination was determined by measuring the DCB derivative (1% OV-301 column) and mathematically converting it to tho equivalent amount of the Aroclor used as reference in the total area quantitation. Comparison of the residue levels obtained by the two determinative procedures are presented in Table 4. Results obtained by the two methods of quantitation arc in close agreement, demonstrating the practical application of the perchlorination procedure for quantitative confirmation. Gas chromatograms of an egg sample (Aroclor HOWS 078010 -12- 1242) quantitated for PCB as a multicomponent residue before pcrchlorination and as the DCB derivative after pcrchlorination are shown in Figuie 2. In the case of the chub samples, the extracts containing residues of both PCB and DDT analogs were separated on silicic acid prior to quantitation of the multicomponent PCB residues. Aliquots equivalent to 0.3 grams chub from the silicic acid petroleum ether (PCB) fraction were perchlorinatcd and results compared (see Table 4). Gas chromatograms of a chub sample quantitated for PCB (Aroclor 1254) es a multicomponent residue before perchlorination and as the DCB derivative after perchlorination are shown in Figure 3. Figures 2 and 3 also illustrate the increase in sensitivity obtained by pcrchlorination. For approximately equivalent pea); heights on GLC only about 1/16 as much of the egg sample (Aroclor 1242) and .1/lOas .mv\ch of the chub sample (Aroclor 1254) were injected after pcrchlorination as was needed befere perchlorination. Organochlorine pesticides, if present in a sample, should be separate--* from PCB prior to derivatiring the residue to DCB. Pesticides such as DDT may be chlorinated to derivatives other than DCB. Preliminary studies show that perchlorination of DDT itself results in the formation of several derivatives which arc separated from DCB on the 3% Dexsil 300 column at the specified conditions and do not interfere. Conclusions The perchlorination procedure developed for microscale qualitative and quantitative confirmation of PCb is routinely applicable to samples prepared for GLC residue analysis. It reinforces judgments made by the HGNS 078819 -13- analyst when dealing with a multicomponent residue. The derivutization procedure coupled CLC x><`rametcrs used for chromatographing PCB also greatly inerftsen the sensitivity of PCB detection. HONS 078620 Bib!iography (1) Peakall, D. B. and Lincer, J. L., Dioscience 20^, 958-964 (1970) (2) Reynolds, L. M. , Residue Reviews 34^ 25-57 (1970) (3) Riscbrough, R. W.f Reiehe, P., and Olcott, H. S., Bull. Environ. Contain. Toxicol. A192-201 (1909) (4) Armour, J. A. and Burke, J. A., JAOAC 5^3, 761-760 (1970) (5) Aroclor Plasticizers, Technical Bulletin 0/PB306, Monsanto Co., St. liOUiS, Mo. (6) Armour, J. A., J. Chromatog., accepted for publication (7) Berg, 0. W., Diosady, P. L., and Rees, G. A., Bull. Environ. Contain. Toxicol. 1_, 338-347 (1972) _ (8) Hutzinger, 0., Safe, S., and Zitko, V., Intern. J. Environ. Anal. Chem. (to be published Nov. 1572) (9) Wiencke, W. W., U. S. Food and Drug Administration, private communi cation, January 1972 (10) Pesticide Ai.alytical Manual, Vol. I, Food and Drug Administration, Washington, D. C., 1972 (11) Stalling, D. L., Bureau of Sports Fisheries and Wildlife, u. S. Department of the Interior, Columbia, Missouri, private communication, October 1972 (12) Official Methods of Analysis, 11th Ed., AOAC, Washington, D. C., 1970 MONS 0 788.21 Table 1. Factors to Mathematically^^onvert Decachlorobiphenyl to an Equivalent Amount ArocloxM Aroclor Averaqe No. Cla MW** si 1221 1 188.5 0.38 1232 2 223 0.45 1242 3 257.5 0.52 1016 3 257.5 0.52 1248 A 292 0.59 1254 5 326.4 0.65 1260 6 361 0.72 1262 7 395.3 0.79 DCB 10 499 i a Average whole number of chlorines calculated from percent cilorine substitution for a specific Aroclor. b Molecular weight of Aroclor based on the average whole number of chlorines calculated from percent chlorine substitution. c * " molecular wt. Aroclor molecular wt. DCB (499) . To convert ppm DCB to ppm of a specific Aroclor multiply ppm DCB by "XM for the Aroclor. *ONS 078822 Table 2. Percent Conversion of 1 yg PCD to Decachlorobiphenyl at Overnight Conditions. Aroclor 1242 1016 1248 1254 1260 1262 Trials 10 5 5 5 5 3 Ranqe (%) 90-105 87-105 98-102 95-104 90-95 89-103 Average 97 95 99 100 93 95 MCNS 078623 Table 3. Percent Conversion of 1 pg PCD to Decachlorobiphenyl with Iron Catalyst and Six Hour Reaction Time. Aroclor 1242* 1242 1016 1248 1254 1260 1262 Trials 10 10 3 3 3 3 3 Range (%) 78-90 96-110 87-95 95-100 98-106 91-108 83-107 Average (%) 90 102 92 98 103 98 98 *4 hour reaction. MGNS 076824 Table 4. PCD Residue Levels in Environmentally Contaminated Sample: Obtained by Two Different Methods. of Quantitation. Sample Reference Aroclor Chub 1254 Chub 1254 Chub 1254 Chub 1254 Sturgeon a 124B Eggs 1242 Chicken Tatb 1242 Chicken atb 1248 PPM Residue . by Total Area by DCR*c Trial #1 Trial i\2 3.5 4.2 3.4 4.2 4.2 5.1 3.4 4.5 28.4 28.6 28.4 7.1 6.8 7.1 4.6 5.0 6.9 6.6 a Residue is reported on a fat basis. b Samples fortified with Aroclor for an intorlaboratory study, c Expressed as reference Aroclor. jf HONS 078825 Figure ]. Vacuum hydrolysis tube recommended for sealed system reaction A. Dimensions 10 mm o.d. X 150 mm length. B. Tight Teflon sealing valve. C. Venting side am. MCS 018626 Figure 2. GLC curves of egg samples 7.1 ppm PCD (as Aroclor 1242) before and after perchlorination. A. 1.11 mg sample (7.9 ng Aroclor 1242) 6* Florisil eluate before perchlorination, lOt DC 200 column (10,12). B. 0.07 mg sample (0.5 ng equivalent Aroclor 1242) 6% Florisil eluate after perchlorination, 1\ OV-101 coluirtn; ' GLC conditions given under "Methodology". A MCNS 078829 Figure 3. GLC curves of chub sample calculated as 3.4 ppm PCU (as Aroclor 1254) before perchlorination and calculated as 4.2 PCB (as Aroclor 1254) after perchlorination. A. 1.5 mg sample (5.1 ng Aroclor 1254) petroleum ether eluate from silicic acid before perchlorination, 10% DC 200 coluion (10,12). D. 0.15 mg ample (0.63 ng equivalent Aroclor 1254) petroleum ether eluate from silicic acid after perchlorination, 1% OV-101 column. GLC conditions given under "Methodology." HQHS 078830 yr MGNS 0 7 8 6 3 1 ATTACHMENT VI LABORATORY INFORMATION BULLETIN EDRO March 23, 1972 No. 91B1I Post ic ides Page 1 of 12 ADDITIONAL INFORMATION ON THE BEHAVIOR OF TOLYCHLORINATED BIPHENYLS AND POLYCHLORINATED TERPHENYLS IN RESIDUE METHODOLOGY Los Angeles District Buffalo District Division of Chemical Technology Interest has continued to grow In the analytical aspects of polychlorinated biphenyls and terphcnyls (PCB/PCT). Emphasis on the Identification and mo.asurement of the residues themselves has surpassed the original concern of preventing their Interference in pesticide residue analysis. Experimental investigation and Industry contact has led to elucidation of composition of several Aroclor reference materials. In addition, a number of short term studies were done to determine the behavior of Aroclors in various analytical procedures, and tre responses of several GLC detectors to the chlorine content of Aroclors were compared. Experimental data presented here were collected by: Herbert Masumoto and Milton Luke of Los Angeles District; Robert V. Hoffman of Buffalo District; Judith Armour, John Roach, Winfred Wlencke, and Susan Young of Division of Chemical Technology; and compiled by Bernadette McMahon of DCT. Aroclor 1232 Reference Material Hew Information on the manufacturing process for Aroclor 1232 sheds lights on the reason for the differences among the chromatograms of several samples of 1232 obtained from Monsanto at different times. It has been revealed that when Aroclor 1232 vaa being manufactured for sale (It la no longer available), it was made by combining amounts of Aroclors 1221 and 1242 until the mixture con.ained 32% chlorine by weight. This Information explains how It is possible that the gas chromatograms of some lots of Aroclor 123? reference materials have resembled chromatograms of 1242, and others have more closely resembled chromatograds of 1221. MGhS 078632 March 23, 1972 ATTACHMENT VI No. 91fl H Pesticides Page 2 of 1 It is probable that the manufactured lots of Aroclor 1232 varied In composition from one to another. For this reason, residues of Aroclor 1232 that may be found would be unlikely to match any arbitrarily chosen 1232 reference material. It la therefore recommended that residues suspected of being "Aroclor 1232", but resembling Aroclor 1221 and /or 1242, be quantitated by comparison to Aroclor 1221 and /or 1242 reference rather than by comparison to an Aroclor 1232 reference. Prom now on, Aroclor 1232 will not be considered a separate entity, and lists of data on the behavior of Aroclors In this LIB will not include Aroclor 1232. Significance; Little Aroclor 1232 was ever sold (according Monsanto) and none is available now, so residues of "1232" are not likely. The suggested means of quantitation is available only in case such a residue is found. to Toxicological and ecological reasons for identifying the residue will not be jeopard.zed by reporting the residue as 1221 and/or 1242 rather than as 1232. Ar o c 1 or s 4 4 6 *>, 5442, and 5460 Reference Materials By definition of the manufacturer, the Aroclors named in the tl.le are composed of mixtures of the following: 4465 - chlorinated biphenyls and terphenyls, with 65X chlorine by weight 5442 - chlorinated terphenyls, with 42% chlorine by weight 5460 - chlorinated terphenyls, with 60% chlorine by weight Chromatograms of each of the above mixtures were presented in LIB 918F. These chromatograms were obtained at conditions normally used for the chromatography of the mixtures of chlorinated biphenyls. It has since been discovered that, at these conditions, the chlorinated terphenyls present in 4465, 5442, and 5460 were seen, at best, only as vjry late eluting peaks. In turn, this failure of the chromatographic system to visualise the terphenyls led to some Inaccurate results in other experiments which used GLC as a determinative step. Recent investigations from several sources have revealed new information about the Aroclors In question. In pari, the evidence has been obtained by use of a GLC column which permits terphenyls, to elute quickly enough to be easily seen and measured (LIB 918 C). MCNS 078833 ATTACHMENT VI .Hatch 23 , 1972 No. 918H Pesticides Page 3 of 12 Mew findings on the Aroclors of Interest follow. 4465: The reference material distributed to FDA Districts by the former Reference Standards Branch appears to be mostly biphenyl compounds, despite Monsanto's description of this mixture as 40:60 terphcnyl: biphenyl. Chromatography of 4465 on a GLC column which permits visualization of terphenyls docs not reveal the presence of additional significant compounds. Because the 4465 reference material obtained from Monsanto by FDA docs not match Monsanto^ description of the product, it Is suspected that the terphenyl: biphenyl proportion must vary among different manufactured lots. The description of the material as a combination of terphcnyl and biphenyl also suggests that 4465 may have been made by combining amounts of other Aroclors until 65% chlorination was obtained. Therefore, It may be possible to handle residues of "4465" by comparing them to other Aroclor references which they resemble. Monsanto no longer manufactures Aroclor 4465, so no additional samples of reference material are available. For this reason, data presented In other sections of this LIB were obtained using the reference material containing mostly chlorobiphenyls. 5442: The reference material of 5442 available In FDA contains some contamination with chlorinated biphenyls, as evidenced by the early eluting peaks in the chromatograms in LIB 918F. The contamination Is relatively small, and the data for 5442 presented elsewhere in this LIB were obtained by measuiing the recovery of the terphenyls with a CLC column which permits the terphenyls to elute quickly. 5460; The 5460 distributed as .i reference material has now been shown to contain a relatively large (about 5%) contamination of chlorinated biphenyls. It is now apparent that only the biphenyl contaminant was being visualized by the CLC systems used in LIB 918F, which explains why the chromatograms of 5460 resembled 1260 so closely. The chlorinated terphcnyl components of 5460 can be seen and measured when the alternate GLC column is used. Data on the behavior of 5460 presented elsewhere in this LIB were obtained using the alternate column to visualize the terphenyl components of 5460 for measurement. Sign 1f1cance: Residues of chlorinated terphenyls are presumably of as much Interest and Importance as those of chlorinated biphenyl*. Until recently, the capability for detecting and measuring (Chloroterpheny 1 residues was limited by the very long retention times and consequent poor sensitivity for the compounds on the GLC columns (PAM 311.2) normally used for analysis of chlorinated biphenyls. . The chlorinated terphenyls arc recovered, at least partially, through the Analytical procedures used for organochlorine p&stlcldes and PCU (see other sections of this LIB for details). It Js now possible, by means of the GLC column described by Wlencke (LIB 918G), to visualize residues of chlorinated terphenyls and to estimate their quantity against a known amount of M0NS 07883'. March 23, 19 72 . n t uivik -.1 * * *. . No 91811 Pesticides Page 4 of 12 reference materiel. T!tir. Is the recommended procedure for detection and mcasurer-icni: of residues in samples suspected of contamination with chlorinated terphenyls. In particular, samples whose preliminary GLC analysis shows peaks eluting beyond the retention times of chloilnated biphenyls should be injected on the "alternate column to visualise any terphenyls present. Chlorotcrphonyl residues too low to be recognized in ordinary sample examination can be discovered by injections of the sample on the alternate column. Variations in Partitioning Among PCB/PCT It has been determined that the efficiency of transfer of PCB from petr ether to acetonitrile decreases with increasing chlorination of the compounds. In particular, the following recoveries of Aroclor standards were obtained when a known amount of each Aroclor in 15 ml petr ether was partitioned into four successive 30 ml portions acetonitrile, each acetonitrile portion being backwashed with an additional 15 ml petr ether (PAM 1, 211.14b): Aroclor ur in 15 ml PE X rec 12*1 40 94 1242 40 97 1248 40 93 1254 40 87 1260 40 71' 1262 40 74 4465 20 71 Among the PCB components of any given Aroclor, those w'lose peaks eluted first In the normal gas chromatographic system showed the highest recoveries. Percentage recovery decreased with increasing retention times (which generally Increases with increasing chlorination) again suggesting that the more highly chlorinated the isomer, the poorer its transfer from petr ether to acetonitrile. The two Aroclors made up of polychlorinated terphenyls (PCT) display a similar pattern. When Aroclors 5442 and 5460 were partitioned as described above, 92 and 77% of the original 20 ug were recovered, respectively. Recoveries of individual PCT in the Aroclors were not determined, because the GLC column for PCT does not ref.olve the components well enough for measurement of each. Signif1cance: The experiments performed in gathering this recovery data were designed to duplicate the partitioning step most often used in the analysis of fatty foods for % MCAfS 078835 March 23, 1972 No. 9L8U Pesticides Page 3 of 12 organochlorine pesticides and/or PCC. The residue analyst should be aware that recovery through PAM I method 211 (fatty foods) will be different for different Aroclors and should avoid attributing losses completely to the Florisil or silicic acid column chromatographic steps. In addition, the pattern of PCB isomers In a given Aroclor is altered to some degree by this phenomenon), and may cause confusion to the inexperienced analyst. Recovery of Aroclors Through Florisil Column Chromatography New information on the behavior of Aroclors in other parts of the methodology has prompted reassessment of the elution of Aroclors from the Florisil column (PAM 211.I4d). Frequent use of pesticide residue methodology for the analysis for PCB has assured us that the chlorinated biphenyls elute in the 62 ethyl ether/pctroleuro ether eluatc. Additional experiments have shown that Aroclors 4465, 5442, and 5460 are also eluted by the 62 eluant. Recovery of Aroclors Through Silicic Acid Column Chromatography Masumoto (in press, JAOAC) has pointed out that some of the chlorobipheny1 isomers present in Aroclors are not aluted from the silicic acid column by petroleum ether as originally reported. Instead, the chlorobiphenyl isomers with early CLC retention times (which, generally, are those with lowest chlorination) are likely to be held on the silicic acid column and eluted from it only by the second, polar eluant. Aroclors consisting mostly of lower chlorobiphenyl isomerc vf. 11 therefore show low recoveries in the petroleum ether cluate. Recoveries of PCB in the iollowing Aroclors were obtained from a column made of silicic acid and Cclltc (LIB 91BC-E) which had been previously standardized by addition of enough H2O to effect separation of pp'DDE and Aroclor 1254: Aroclor Recovery 1221 essentially all in polar eluate 1242 20-35X In polar eluatc 1248 less than 202 in polar eluate 1254 completely In petroleuo> ether 1260 completely In petroleum ether 1262 .completely in petroleum ether 4465* completely in petroleum ether HONS 078836 March 23, 1972 Ho. 91811 Pesticides Page 6 of Reference material contained mostly polychlorinated biphenyl iaomera, rather than both biphenyl and terphenyl isomers. The silicic acid column chromatography of the two Aroclors consisting of PCX was also examined . All of the Aroclor 5442 and most of the Aroclor 5460 added to a silicic acid column was eluted by the polar eluant. Aroclor 5460 Was partially eluted by the petroleum ether eluant. Significance? Knowledge of the elution characteristics of the Aroclors from the silicic acid column will aid the analyst in his choice of the appropriate analytical treat ment of samples containing both pesticides and PCB. If exam ination of the original GLC chromatogram shows the PCB to resemble an Aroclor known to be incompletely separated from pesticides by silicic acid, alternate treatment(s) can be chosen to permit quantitation of the residues. Response of CLC Detectors to the Chlorine Content in Aroclot_s Experiments were performed to determine whether the responses of the electron capture, microcoulometric and electrolytic conductivity detectors were proportional to the ihlorine content of Aroclors regardless of the nature of the compounds comprising the Aroclor. Results Indicate that the response of the halogen specific microcoulometric and electrolytic conductivity detectors to the same amount of chlorine in different Aroclors was essentially the. . In tontrast, the response of the electron capture detector to the more highly chlorinated ArocLors was disproportionately high when compared to the response of the same detector to Aroclors with lower chlorine content. The electron capture detector that was used was first shown to give reproducible results and to be linear in response to amounts of heptachlor epoxide Injected. Then, injections of six Aroclors were made and the total area of response measured for each. Calculations were performed so that responses to the different Aroclors could be compared to one another, on the basis cf response/weight chlorine. The following ratios ware obtained in this way: Aroclor Relative Response/Weight Chlorine 1221 1 1242 3.0? 1248 4.56 MGNS 076837 March 23, 1972 ATTACHMENT VI No. 91811 Pesticides Page 7 of 12 54 9.64 1260 1262 12.70 10.35 It-is obvious from these data that response of the EC detector i8 not proportional to the amount of chlorine present in the chlorobiphenyl molecule. - In contrast, the response of the mlcrocoulomctrlc detector to injections of the same amounts of chlorine in each of four different Aroclors was essentially the same for each Aroclor. Because detector sensitivity changed with time, ratios of response to Aroclor X are compared; the injection of Aroclor ffeAponsc to Aroclor 1242 1242 and the injection of the other Aroclor were always made within an hour of one another. Other special precautions were also utilized to improve reproducibility; e.g., the first two injections made after cell flushing and equilibration were not considered. The following ratios were obtained: R c 1 a tive Response (for SLine weight chlorine) Aroclor Meat Range (number of injection!;) 1242 1.00 (used as 6tndard) 1248 0.97 0.90-1.03 (3) 1254 1.00 0.92-1.23 (5) 1262 1.10 ... 0.86-1.26 (6) Despite the problems encountered in dealing with the microcouloetric system, these data do present evidence that mlcrocoulometric response is essentially proportional to the amount of chlorine present, regardless of the structure of the compounds. Figures 1-5 demonstrate visually the contrast between EC and mlcrocoulometric responses to chlorine content in the "'CB contained in Aroclors. In particular, the lower chlorinated Aroclors and the early eluting (lower chlorinated) PCB within the Aroclors show the most marked difference in pattern * between EC and mlciccoulomotric responses. This cricct is consistent with the data on EC and mlcrocoulometric responses presented above. Note that the amounts of each Aroclor Injected HONS 078830 March 23, 1972 MTACHMENT VI No. 91SH Pesticides Page 8 of 12 vary and that no attea.pt has been made to compare Instrument sensitivity In these chromatograms. The electrolytic conductivity detector was also shown to respond to the chlorine content of PCB in a study using a Coulson electrolytic conductivity detector specific for halogens. The system was operated in the reductive mode and utilized a platinum catalyst. Two injections each of Aroclor 1221 through 1260 were made and compared to the response of Aroclor 1242 which was used as a reference. The reference was injected immediately prior to the Aroclor being checked in each case. Aroclor 1242 was also used as a means of checking the sensitivity of the detector which varied from day to day and even during the course of a day's operation. For these calculations the response for Aroclor 1242 and the Aroclor being checked were measured by planimeter in square Inches. In this regard it was noted that the linearity for this detector appeared to drop off sharply when the response fell below 0.09 in.2/ng chlorine, which was due prinarily to the inability to accurately measure all the peaks in the reference or Aroclor being tested. Results were as follows: Aroclor ng Injected Response in ^/ng Cl Respotse to Aroclor Response to Aroclor 1242 1221 125 0.12 1.01 1221 112.5 0.12 1.00 1242 Used as Keferrnce 1.00 1248 115 0.09 1.05 1248 125 0.09 0.99 1254 125 0.10 1.01 1254 100 0.10 0.99 1260 125 0.09 1.02 1260 150 0,09 1.08 Slgnifiennefe. The use of Aroclors as reference materials for the quantitation of PCB residues involves inherent problems because the residue is rr.est often altered in composition from the original Aroclor. Alteration can occur in several ways; e.g. , weathering p.ii/or metabolism, preferential storage of certain components in ailmals, variations in recovery of components through the methodology (described in this LID) , and variation in MCNS 078839 March 23, 1972 ATTACHML'KT VI No. 9 llilt Pesticide;; Page 9 of the amount of loss through volatilization of the different components (to be described in a forthcoming report from LOS-DO). The accuracy of the quantitative result decreases with the increasing alteration of the PCB residue from the pattern of the. Aroclo; reference. The disproportionate response of the EC detector to the more highly chlorinated components aggravates the problem of quantitation of an altered residue. The analyst should be aware of these limitations and, if possible, quantitate altered residues using one of the halogen-specific detectors and reference Aroclor(s) whose pattern matches that of the residue most closely. This should minimize the problem until such time when an improved method of quantitation la available. MCfcS 078840 March 23, 1972 ,| - >' i! EC :: 44ng pie i No. 9J8H Pesticides Payc 10 of 12 .Aroelor 3 2 21 f HONS 078341 NO . * 1 oil P(u?L icidos 1' ri C i: 11 of 12 i i. Fig. 4 Ar-iclor 1254 HONS 078842 Xo. 918H Pesticides Pag'3 12 of 12 ATTACHMENT VI Kerch 23, 1972 / Fig. 5 Aroclor 1260 HGNS 0 7 8 6 4 3 Instrument Conditions : Figures 1-5 f.C : 111 DC 200 col, PAX I 311.2 Parameters; 70V; 1 x 10-? afs :*.c 2 DC 200 col. at 2O0*C, 120 ral/min Nji injector tenp 225#C; logen specific detector, 10'i/l. gai'i ?5.