Document ExGk4EBYbOMJp3kV8ybKE6gM0
I hooKer HUGO DtVtSON
LEN FABRIZIO
Copies to:
R. GAZD/T' R. LaRUE A. TYBUS
subject:
TRIP TO PVC CONTAINER CORP.
INTER-OFFICE MEMORANDUM
File Ref.: PTC-100921-8-DB/mjw Date 10/20/78 From: David Blaushild Div./Dep't: RUCO/PTC Location: BURLINGTON
On Friday, October 13, 1978, Dick LaRue and I met with Jim Stewart and Wally Wolniansky of PVC Container Corp. in Eatontown, N.J. to monitor for HCL gas. The tests were performed at the request of the customer to determine what improvements were made upon installation of fume jioods over their blow molders.
The areas monitored and conditions used were the same as on our last visit, August 4, 1977 (see memo #PTC-10072-7-LF/mw, August 11, 1977).
The HCL levels given below are expressed in parts per million, the time intervals
tn minutes at which the readings were taken, and the area being monitored. The
readings taken on August 4, 1977 as well as the readings obtained on October 13, 1978
are presented here:
(minutes)
August 4, 1977
October 13, 1978
AREA
TIME
HCL (PPM)
HCL (PPM)
(1) Machine Shop
initial 5 8 10 15
35-41
-
-
5.35-8.9
*3 * ^3 <3 <3
-
(2) Mold Room
initial 5 8 10
4.45-5.35
2.68-3.57 ^3
3.57-5.36
*3 ^3 *3 -3
(3) Area in front of Machine #3
initial 5 8 10
8.9-10.7 7.14-8.9 5.35-8.9 5.35-8.9
<3 <3 <3 <3
(4) On Top of Machine #3**
FOAM NO* 91*09#
Initial 3
26.78-35.7 8.9-17-8
<3 3.5
(These readings ri ipeated approximately every 12 seconds correlating to the mold cycle)
(ontinued on page two)
OCC 018128
Il hooKer RUCO OIVISION
p O . BOX 4 S <( R | V E R R O A O . BURLINGTON, NEW JER1EV tit I I
PHONE: 490*2900
October 20, 1978 PTC - 100922-8-LF/mjw
Mr. W. Walnlansky, Plant Manager PVC Container Corporation 556 Industrial Way Eatontown, New Jersey 07724
Dear Wally:
Attached please find H.C.L. monitor test results that were obtained on October 13, by our Technical Represent ative, David Blaushild. It is gratifying to report the vast improvement in the H.C.L. levels present in your facility. We trust these levels meet with your approval.
Please contact me if we can be of further service to you.
Very truly yours,
LF/mjw Enc. (1)
Compound Development Polymers Department
hooker chemical corporation
OCC 018129