Document EvxqdnnY2xaB3Q1718yjBqe6x

Data Sheet Chelsea Proving Grounds August 18,1986 PLAINTIFF'S EXHIBIT CIIR-210 Department S720 - ....... Permissible Exposure Limit - Asbestos fibers per cc With lengths> 5 microns Result O.Z1' T. W. A.* 072 Harook;~J r370-34-3626''' ------ " ' ` 0.05 Complete Brake Buildup and Thermo-couple set 0.01 Cook, T. 366-44-6816 Final Pad and Shoe .Inspection < 0.01 < 0.006 Alder, I. 369-40-3369 Brake Shoe Grinder <0.1 <0.006 * Time Weighted Average Samples were taken on 25 im cellulose ester filters and analyzed by phase contrast optical microscopy. i / 9 Data Sheet Chelsea Proving Grounds ASBESTOS Location OSHA Permissible Exposure Limit (eight hour time-weighted average) OSHA Ceiling Concentration (not to be exceeded at any time) Concentration (fibers per cubic centimeter of air) 2.0 10.0 1) Personal air sample, D. Bauer 0557, grinding L-car linings on Ammco grinder in Brake Lab <0.1 eight hour time-weighted average <0.1 2) Personal air sample, L. Stark 4047, removing brake shoes to reset thermocouple 0.4 eight hour time-weighted average< 0.1 * E = CaTa * CbTb + ......... . CnTn total Time E a equivalent exposure for the working shift, i-.e., eight hour time-weighted average C concentration during any period of time T ; .".3 ; . . *' ; . ___ T a is the duration of the exposure at the concentra tion C >- .-T ................. (0.4) (30) (0) (450) --- 12_ 480 0.025 All determinations of airborne asbestos fiber concentrations were made by the Industrial Hygiene Laboratory using the membrane filter method at a magnification of 430X with phase contrast illumination. DATA SHEET CHELSEA PROVING GROUND ASBESTOS MONITORING ASBESTOS (fibers/cc) Permissible Exposure Limit 0.2 8/17/89 - Vehicle Test DepartmentGeorge Burns, 370-36rll2&. _________ <0.02 The above sample w*s~corHseted-on a cellulose ester filter, utilizing a MSA Model- -'G~ pump with analy.sxs_by phase-contrast microscopy in the Chrysler Industrial Hygiene Laboratory.^ . --- ...______________ CPGBRAKE.GFW DATA SHEET CHELSEA PROVING GROUND ASBESTOS MONITORING ASBESTOS Fibers/cc >5 microns Permissible Exposure Limit Action Level---------------------- 0.2 0.1 10/12/89 - BrakV^nspegClron"Operations Mike PoxsonV 298-58-5984 Driver/MecHahic" ' <0.03 The above sample waS^'cMIeeted* on an asbestos collection cassette using a calibrated MSA Model "G" pump with analysis performed at the Chrysler Industrial Hygiene Laboratory. CPGASBBR.GWF