Document EvvepJONVg31en0ypZjVx2bK0
PLAINTIFFS EXHIBIT UC-69.8 . ...
ASBESTOS FIBER COUNTS OF AIRBORNE SAMPLES COLLECTED FOR
BAKER & TAYLOR, CANADIAN, TEXAS
September 28, 1972
PERSONNEL PRESENT Baker & Taylor
Montello, Inc.
G. Good
R. Newman H. Wyatt
Union Carbide Corporation:
' e. J. Kleber*-^
UNION CARBIDE CORPORATION Mining and Metals Di'ision
i
OBJECTIVE
Monitor airborne asbestos in an actual on site condition inside a mud house.
INTRODUCTION
On September 28, 1972 tests were conducted at a Baker & Taylor drilling site about 40 miles from Canadian, Texas. All samples were collected in a mud house approx. 25' x 7' with a Quonset hut roof 7 ft. high at the zenith. Two asbestos products were evaluated; Super-Visbestos, essentially 100% liberated fiber, and Mew Granular Super-Visbestos , a pelletized form.
TEST METHOD
11:15 - 12:45 - 10 bags Super-Visbestos added to hopper.
12:45 - 2:10 - 10 bags Mew Granular Super-Visbestos added to hopper.
The first hour of each test was the dumping of asbestos, 1 bag every 6
minutes. The last half hour was monitored as a settling period.------' ~
"
SAMPLER LOCATIONS - (See Figure 1)
The samplers v/ere left in the same spots for each test. They are designated as Position 1, 2, and 3.
Position 1 - 4 ft. from hopper in somewhat of a "dead" air area, 5-1/2 ft. above floor.
Position 2 - At opposite end of mud house, 3 ft. from door,- downwind from hopper, 5-1/2 ft. above ground.
Position 3 - Operator dumping bags at the rate of 10/hour.
EQUIPMENT
Sampling and dust counting were carried out in accordance with 0SHA Regulation 1910.93a.
Personal air samplers were used to collect personal breathing zone and environmental samples on Millipore Membrane Filters of 0.8 micron porosity.
Air samplers were as follows:
MSA Personal Sampler - Calibrated to draw 2 liters per minute of air. Used in position 3.
Unico Personal Sampler "A" - Draws 1.8 liters per minute. Used in position 1.
Unico Personal Sampler "B" - Draws 1.7 liters per minute. Used in position 2.
Fiber counting was performed on a Leitz Microscope utilizing Phase Contrast Illumination at 400X and a Patterson Globe and Circle Reticle.
' TEST RESULTS'- (See Table 1)
Table 1 contains the results of the sample analysis dust counting. The count is reported as fibers greater than 5 microns in length per milliliter of air sampled. fiber is defined as any material having an aspect ratio greater than 3.
A-:.
INTERPRETATION
Although the figures speak for themselves, it may be worthwhile to briefly review the Time Weighted Average (TWA) aspect. The Regulations have been established with a limit of 5 fibers per milliliter greater than 5 microns in length on a Time Weighted Average. This means the figures must be arranged to show the employee's average in take of fibers per milliliter on an 8 hour day. For example, a worker dumping asbestos for one hour per day and inhaling _8 fibers per milliliter during that hour would have a TWA of 1 fiber per milliliter and for 2 hours dumping at the 8 fibers per milliliter level would be 2 fibers per milliliter, etc. The highest reading in Table 1 is 1.03 fibers per milliliter and the operator was exposed to this level for 59 minutes. If this were his only exposure during the day, his TWA would be less than 0.2 fiber per milliliter.
i 1.3. No. .
1929-35-1 -2 -3 -A -5
TABLE I
SUMMARY OF DUST COUNTS
Fi eld No.
(Minutes)
Positi on
Descri pti on
Dumping of 10 bags Super-Visbestos
33 60 41 61 47 59,,
9 27 34 27
1 Environmental 2 Environmental 3 Personal 1 Env. - After Dump 2 Env. - After Dump
t r;..
Fi bers/ml >5
0.40 0.20 1.03 0.44 0.31
Dumping of 10 bags New iGranular Super-Visbestos
-6 15
-7 n
-8 10 -9 42 10 46
59 60 59 25 25
1 Environmental 2 Environmental 3 Personal 1 Env. - After Dump 2 Env. - After Dump
^ - : //' - 1
C A>. -r
V:, ;
^
0.47 0.35 0.49 0.32 0.16
7 ft-----------i>
FIGURE 1