Document Evv5vq5LDROOeyyEeXJZ5ajrR

690 CHAPTER 26 1957 Guide must be used in the U-bend to take up the deformation, A. When weld ing fittings are used, the radii should be six times the outside diameter of the pipe. One other restriction is that the pipe should not be heavier than extra strong. Manufacturers of pipe, or pipe fittings, often publish excellent treatises on the simplification of expansion problems. It is suggested that the engineer obtain such publications and also a text or handbook4 on the sub ject before attempting to solve a problem on flexibility. HANGERS AND SUPPORTS In the preceding section, Equation 3 was developed to give the force of total constraint. This equation is appropriate regardless of the sign of Af, positive or negative. It did not, however, allow for any bending moment but was for straight compression or tension. Tabu: 21. Equations fob Bending Stress and Deflection between Supports Type of Support Bending Stress, psi S Deflection, Inches Y ,, 0.75WL*D I - 0.5WL*D 1 22.5 WL* El ,, 4.5 WL4 Y ~ El where ' W = Total weight (pipe, fluid, etc) pounds per foot. D = 0. D. of pipe, inches. L = Length of span, feet. E = Modulus of elasticity, pounds per square inch. 1 = Moment of inertia, (inches)4. I = -- (OD4 -- ID4), O. D. and I. D. in inches. 64 If the compressive force is great enough, or if the line is long enough, a slight eccentricity of the load application will cause a buckling of the line. This buckling is identical with the action of a column under excessive compression. : In fact, a pipe fine in compression is identical to a column. Column criteria can therefore be used for selecting the action of supports to resist lateral thrust. A common equation for determining safe column loads is Euler's for mula: S = (for cast iron see Equation 8) (5) where S = allowable column load, pounds per square inch. k -- radius of gyration, inches. I = column length, inches. I 0D* +ID* 16 Pipe, Fittings, Welding 691 Equation 5 is sometimes modified by a correction factor C to the following: S = CV*E 0^ (6) where C = correction factor depending on end loading in accordance with the following table: End Conditions of Column One End Fixed Fixed Fixed Pin Other End : Fixed Free Pin Pin From Equation 6, l = rrk CE Value of C 4.00 0.25 2.25 1.00 - (7) This equation is not used for column construction but is sufficiently accurate for the work of a heating engineer. The equation is modified for cast iron because of its poor tensile strength. It is generally acceptable to use one-half the value of S from Equation 5 for cast iron, so it becomes '. for cast iron. (8) It is permissible to allow the l/k ratio for steel to go as high as 120, but for cast iron the desirable maximum , is taken as 70. It is not to be under stood that a fracture will occur at l/k ratios in excess of those given, rather it is to be understood that lateral support should be given for those ratios and for those magnitudes of stress. If an expansion joint is used, this wnl, of course, relieve the compressive stress. Example: For the problem given in the above section, the constraining force for pipe*? Plpe WaS What is a required spacing for lateral support for this Answer: Using Euler's formula, Equation 5 gives *(i)' { = vky/E/S ^'0r a 1 in. Schedule 40 steel pipe ^ = 0.4205 inches. ^ ~ 30,000,000 pounds per square inch. S = 9630 *4- 0.494 = 19500 psi ^ ^ 51.8 inches. Therefore, lateral supports on 4 foot centers would be adequate. to th ^.er f load requiring some support is the bending stress due toe weight of the pipe, its insulation, and of the fluid being carried.